Multi-view fast-ion D-alpha Spectroscopy Diagnostic at ASDEX Upgrade

Geiger, B.; Dux, R.; McDermott, R. M.; Potzel, S.; Reich, M.; Ryter, F.; Weiland, M.; Wünderlich, D.; García Muñoz, Manuel

Abstract

A novel fast-ion D-alpha (FIDA) diagnostic that is based on charge exchange spectroscopy has been installed at ASDEX Upgrade. The diagnostic uses a newly developed high-photon-throughput spectrometer together with a low-noise EM-CCD camera that allow measurements with 2 ms exposure time. Absolute intensities are obtained by calibrating the system with an integrating sphere and the wavelength dependence is determined to high accuracy using a neon lamp. Additional pertur-bative contributions to the spectra, such as D2-molecular lines, the Stark broadened edge D-alpha emission, and passive FIDA radiation have been identified and can be subtracted or avoided experimentally. The FIDA radiation from fast deuterium ions after charge exchange reactions can therefore be analyzed continuously without superimposed line emissions at large Doppler shifts. Radial information on the fast ions is obtained from radially distributed lines of sight. The investigation of the fast-ion velocity distribution is possible due to three different viewing geometries. The independent viewing geometries access distinct parts of the fast-ion velocity space and make tomographic reconstructions possible.

Full text

REVIEW OF SCIENTIFIC INSTRUMENTS 84, 113502 (2013) Multi-view fast-ion D-alpha spectroscopy diagnostic at ASDEX Upgrade B. Geiger,1,a) R. Dux,1R. M. McDermott,1S. Potzel,1M. Reich,1F. R y t e r , 1M. Weiland,1 D. Wünderlich,1the ASDEX Upgrade Team,1,b) and M. Garcia-Munoz2 1Max-Planck-Institut für Plasmaphysik, EURATOM Association, Boltzmannstr. 2, 85748 Garching, Germany 2Faculty of Physics, University of Seville, Seville, Spain (Received 5 September 2013; accepted 22 October 2013; published online 12 November 2013) A novel fast-ion D-alpha (FIDA) diagnostic that is based on charge exchange spectroscopy has been installed at ASDEX Upgrade. The diagnostic uses a newly developed high-photon-throughput spectrometer together with a low-noise EM-CCD camera that allow measurements with 2 ms exposure time. Absolute intensities are obtained by calibrating the system with an integrating sphere and the wavelength dependence is determined to high accuracy using a neon lamp. Additional perturbative contributions to the spectra, such as D2-molecular lines, the Stark broadened edge D-alpha emission, and passive FIDA radiation have been identified and can be subtracted or avoided experimentally. The FIDA radiation from fast deuterium ions after charge exchange reactions can therefore be analyzed continuously without superimposed line emissions at large Doppler shifts. Radial information on the fast ions is obtained from radially distributed lines of sight. The investigation of the fast-ion velocity distribution is possible due to three different viewing geometries. The independent viewing geometries access distinct parts of the fast-ion velocity space and make tomographic reconstructions possible. [http://dx.doi.org/10.1063/1.4829481] I. INTRODUCTION Good confinement of fast ions generated by neutral beam injection (NBI), ion cyclotron heating, or fusion processes is essential in fusion devices because these supra-thermal particles are responsible for plasma heating and current drive and can be critical for the machine safety.2Their distribution function must consequently be investigated by diagnostics that can access different parts of the corresponding six-dimensional phase space. Several approaches have been developed to monitor the fast ions, such as the measurement of neutrons,3gamma rays,4Doppler shifted micro waves,5 and fast-ion losses.6In addition, a widely applied technique to obtain information on the fast ions is based on their charge exchange reactions with neutrals. Along NBI lines, fast ions can capture electrons from the injected neutrals and surrounding halo neutrals with high probability. If the fast ions are neutralized by these reactions, they are no longer confined by the magnetic field and can be detected by neutral particle analyzers (NPA),7located outside the plasma. In addition, their line radiation due to the bound electrons can be analyzed by means of spectroscopy. The charge exchange radiation from fast helium ions has, for example, been analyzed at TFTR8 to obtain information on the alpha particle population in D-T plasmas. In recent years, however, the analysis of fast deuterium ions, i.e., the fast-ion D-alpha (FIDA) method,9has become a valuable tool at several fusion devices.10–15 The FIDA method analyzes the strongly Doppler shifted Balmer alpha radiation (λ0=656.1nm, n=3→2) and makes use of several lines of sight (LOS) that intersect a given NBI path. a)Electronic mail: [email protected] b)For authors list, see U. Stroth et al., Nucl. Fusion 53, 104003A (2013). Good radial resolution of the measurement is possible as the main part of the FIDA radiation is emitted directly after the charge exchange reactions.16 Information on fast-ion density profiles can consequently be obtained from the spectral intensities that are measured using radially distributed LOS. Information on different parts of the fast-ion velocity space can be obtained by analyzing different wavelength regions of the FIDA radiation and by using viewing geometries with different angles to the magnetic field. However, it should be noted that the analysis of the FIDA radiation is demanding: Forward modelling of the spectra is needed for a quantitative interpretation and the signal strengths are relatively weak. The FIDA radiation can be comparable in intensity to the bremsstrahlung and other passive components and is in part superimposed by the NBI induced beam and halo emission. Therefore, optimized LOS geometries, spectrometers, and cameras are needed to enable a detailed analysis of the fast ion distribution. In this paper, the FIDA diagnostic at ASDEX Upgrade1 is presented. This system was designed and built after the feasibility of the technique was demonstrated using an existing CXRS diagnostic in 2010.16 First, the extended LOS geometries and new spectrometer setup are shown, followed by a short description of the applied calibration techniques. The passive spectral contributions that can be superimposed on the FIDA radiation and thereby limit the measurement capabilities are discussed in Sec. III. Section IV reports on the NBI induced active spectral contributions. The beam, halo, and FIDA radiation observed by the three different viewing geometries are presented and the observed regions in the fast-ion velocity space are introduced. Moreover, the possibility to analyze time traces and radial profiles of the FIDA light is presented. Finally, a short summary and outlook are given. 0034-6748/2013/84(11)/113502/11/$30.00 84, 113502-1 30 May 2025 14:28:52 113502-2 Geiger et al. Rev. Sci. Instrum. 84, 113502 (2013) 0 1 2 3 -1.5 -0.5 0.5 1.5 Z [m] R [m] -3 -1 1 3 -3 -1 1 3 Y [m] X [m] Ip Bt pol tor MSE Q3 Q8 Q7 box 1 box 2 pol tor MSE (b) (a) Q3 FIG. 1. Top-down (a) and a poloidal view (b) on the LOS-setup of the FIDA diagnostic at ASDEX Upgrade. The toroidal LOS are indicated in blue color and the poloidal ones are shown in purple. The MSE LOS is plotted in green. The NBI source Q3, which is used as a diagnostic beam, is sketched in orange and the separatrix position is illustrated by red, dashed lines. II. DIAGNOSTIC SETUP A. Line of sight setup ASDEX Upgrade is a medium size tokamak with major and minor radii of 1.65 m and 0.5 m that is equipped with a flexible and powerful set of heating systems. Two NBI boxes, each with four 2.5 MW sources, can generate fast deuterium ions with a full energy of 60 keV and 93 keV, respectively. The FIDA diagnostic is focused on one of the 60 keV heating beams of NBI box 1, labeled Q3. As sketched in Figure 1,all of the lines of sight of the FIDA diagnostic intersect this beam at different radial positions and consequently allow the analysis of radial profiles. 15 toroidal LOS, plotted in blue, are available that view horizontally from their optical head into the co-current direction. The toroidal LOS thereby form angles with the magnetic field lines from 12◦for the central LOS to 21◦for the LOS close to the plasma edge. As can be seen in Figure 1(b), a second optical head is located at the top of the machine. It holds 11 poloidal LOS that are directed downwards on NBI Q3 and form angles to the magnetic field lines between 68◦and 85◦(from center to edge). A third viewing geometry is defined by a single, central LOS, shown in green in Figure 1. This line of sight, which has an angle of about 157◦to the magnetic field lines, was originally installed for motional Stark effect (MSE) measurements17 but is now used by the FIDA diagnostic. The different LOS geometries with respect to the magnetic field lines were chosen because they enable different parts of the fast-ion velocity space to be accessed. In addition, 165 170 175 180 185 190 R [cm] 0 2•10 10 4•10 10 6•10 10 8•10 10 Beam density [cm -3] R = 175.0 +/- 2.1 cm R = 180.1 +/- 3.0 cm R = 185.2 +/- 1.1 cm MSE toroidal poloidal FIG. 2. Radial resolution of three lines of sight of the FIDA diagnostic, based on the calculated neutral density present along the path of NBI Q3. the LOS are arranged such that they yield good radial resolution. The resolution of a given LOS of the FIDA diagnostic is determined by the radial positions at which it intersects the neutral density present along the path of NBI Q3. As shown in Figure 2for three representative LOS, only a limited range of radial positions are encountered. The half widths of the predicted beam and halo neutral density distribution, encountered by the toroidal, poloidal, and the MSE LOS are in the range of only 3 cm. This radial resolution is small compared to the minor radius of ASDEX Upgrade and, hence, allows to study radial profiles. B. Spectrometer and camera setup The light collected by optics in the torus is transmitted with 400 μm thick fibers to a patch panel. From this panel, 15 fibers can be simultaneously connected to one CzernyTurner-like spectrometer that was designed to obtain a high throughput of photons in combination with good imaging properties and high spectral resolution. The spectrometer uses a holographic grating with 2000 lines/mm, has an opening angle φof 20◦, and consists of two Leica objective lenses with focal lengths of 180 mm and f-numbers of 2.8. As sketched schematically in Figure 3, the first lens parallelizes the light emitted by the fibers. The second objective is used to focus the dispersed light of order −1 onto the CCD camera, which is attached to the spectrometer exit. The CCD camera18 has a 512 ×512 16 μm pixel chip and is optimized to detect relatively low signals with a high dynamic range (16 bit). It is cooled 15 fibers 512 pixels 16 channels torus filter first lens second lens grating top-view counts pixels spectrum CCD Φ FIG. 3. Schematic top-down view on the FIDA spectrometer and camera setup. 30 May 2025 14:28:52 113502-3 Geiger et al. Rev. Sci. Instrum. 84, 113502 (2013) to −70 ◦C by a Peltier element, reducing thermal noise, and uses an electron multiplication (EM) gain of the generated photo electrons to reduce the readout noise. An EM multiplication factor of 15 is typically used and it is operated in the frame-transfer mode, which is based on shifting the generated photo-electrons to a second, non-illuminated part of the CCDchip before the readout. The readout time of the camera is 2 ms. This is enabled by the 10 MHz/pixel readout rate and by defining 16 regions of interest (ROI) in which the pixels are binned in the vertical direction. The ROIs correspond to one dark channel for the calibration and to the 15 fibers that are vertically stacked at the spectrometer entrance as the grating does not disperse in this direction. In the horizontal direction, the 512 pixels per channel monitor the dispersed light in a spectral range of about 14 nm (at 656 nm) with a dispersion per pixel of 0.027 nm. The spectral resolution of the diagnostic is, unfortunately, not represented by this value but is rather 0.16 nm. This is due to the spectrometer’s entrance slit which has a width of 100 μm and causes a narrow spectral line with at least this size to be measured when imaged onto the CCD. As shown in Figure 3, the spectrometer design allows us to insert a high pass interference filter between the first lens and the grating that blocks the un-shifted and typically intense part of the D-alpha line. The latter can cause scattered radiation in the spectrometer and can significantly disturb the spectra by saturation effects. In particular, when strong edge D-alpha radiation is present (usually during plasma operation with electron densities above 2 ×1019 m−3) the filter is needed. The filter, however, restricts the analysis of the FIDA radiation to the red-shifted part of the spectrum as it strongly attenuates the light below 657 nm. C. Calibration A proper calibration of the FIDA diagnostic is needed for a quantitative interpretation of the measurement and for comparisons with modelling results. The wavelength calibration of the diagnostic is performed by measuring the well-known and tabulated19 spectrum of neon which has, as shown in Figure 4(a), two strong emission lines between 655 nm and 668 nm. These emission lines appear at slightly different horizontal positions in the 16 camera channels because the vertical alignment of the fibers at the spectrometer entrance causes 0 100 200 300 400 500 0 2 4 6 8 10 horizontal position [pixel] intensity [a.u.] 661.8661.9 662.0 662.1 512 384 256 128 0 central wavelength [nm] vertical position [pixel] (a) (b) neon-lamp spectrum 659.90 nm 667.83 nm FIG. 4. (a) Measured spectrum of the neon lamp between 655 nm and 668 nm. (b) Central wavelength on the CCD as a function of the channel’s vertical position on the chip. A fit to the data with a parabola is shown in red. an additional angle between the light rays and the grating. The resulting parabola shaped channel dependence of the centrally measured wavelength, as shown in Figure 4(b), must consequently be taken into account when allocating wavelengths to the pixel positions. The intensity calibration of the FIDA diagnostic is obtained using an integrating sphere20 that can be placed in front of the optical heads of the FIDA diagnostic when the vessel of ASDEX Upgrade is open and accessible. The sphere emits spatially uniform light in the visible range with a well-known, continuous spectrum. By measuring the light of the sphere that reaches the FIDA diagnostic, calibration factors from the measured counts/s to actually emitted photons/(s sr m2nm) in the vessel can be determined. However, before applying these calibration factors to the raw data obtained during plasma experiments, an offset and smear effect must be subtracted. The offset is measured before every discharge when the CCD is not illuminated and is almost constant in time which makes subtraction possible. The smear effect originates from the camera’s frame transfer operation and is caused by the 310 μs long time interval needed to shift the photoelectrons to the non-illuminated part of the CCD. During this shift-time, the pixels in a given row gather light from the other channels which results in a smeared contribution. When using short exposure times, such that the shift time is a significant fraction of the integration time, this spectral component must be removed. Therefore, a 16th, non-illuminated camerachannel has been defined that only measures the smeared light, which can subsequently be subtracted from the illuminated channels. Uncertainties in the intensity calibration on the order of 10% can arise due to damage or coating of the in-vessel optics during an experimental campaign. In addition, changing the fibers on the switch panel can yield uncertainties because the fiber connections are not 100% reproducible, damage to the fiber optics can occur, and the transmission properties can change (e.g., due to dust getting between the connection of two fibers). Therefore, the amount of switching is kept as minimal as possible and any relative changes that are observed are corrected by analyzing the level of bremsstrahlung in the spectra, which should monotonically increase from the plasma edge to the plasma center. III. PASSIVE RADIATION IN FIDA SPECTRA The spectra measured with the FIDA diagnostic contain active and passive radiation. The active radiation, such as the FIDA radiation discussed later, is only present during the operation of the diagnostic beam (here NBI Q3). In contrast, the passive radiation does not depend on NBI heating and is always present during plasma operation. Example spectra that were measured in discharge #27679 without NBI heating are shown in Figures 5(a) and 5(b) for a toroidal and a poloidal LOS, respectively. Only wavelengths above 655 nm, i.e., red-shifted wavelengths, are monitored as the interference filter, described above, was used in the spectrometer. The data plotted in black were acquired in the presence of an edge-localized-mode, i.e., an ELM-crash,21 and the spectra in gray correspond to a quiescent plasma phase. The spectra during the ELM crash clearly exhibit an increased level of 30 May 2025 14:28:52 113502-4 Geiger et al. Rev. Sci. Instrum. 84, 113502 (2013) 656 658660 662 664 666 668 1016 1017 1018 1019 1020 1021 Ph/(s nm m2 sr) Wavelength [nm] R: 1.850 [m] during [email protected]89s without [email protected] Stark broadening: Tn: 3 eV ne: 9x1020m-3 C II C II N II O II He I bremsstrahlung 656 658660 662 664 666 668 1016 1017 1018 1019 1020 1021 Ph/(s nm m2 sr) Wavelength [nm] R: 1.795 [m] #27697 during [email protected]89s without [email protected] edge D-alpha C II C II He I toroidal poloidal (a) (b) bremsstrahlung O II edge D-alpha FIG. 5. Passive spectra from a toroidal LOS (a) and a poloidal LOS (b) that were observed during (black) and after (gray) an ELM crash. In red, the theoretical shape of the D-alpha emission is plotted, demonstrating the presence of Stark broadening of this line. the individual passive contributions which will be described in Subsections III A–III E. A. Bremsstrahlung The flat background radiation, indicated by green dashed lines in Figure 5, is due to the bremsstrahlung. Bremsstrahlung is mainly caused by electrons that are deflected via coulomb collisions and is emitted in the whole plasma. Its level in the spectra scales with n2 eZeff √Te, where ne is the electron density, Zeff the effective charge, and Tethe electron temperature that are encountered along the path of a given LOS. The level of bremsstrahlung measured by the poloidal LOS during the ELM crash is significantly increased compared to the quiescent time period because ELM crashes cause high densities and sputtered impurities in the divertor region. The poloidal LOS, as shown in Figure 1, end in the vicinity of this region and, hence, can measure large levels of bremsstrahlung. Due to its flat spectral shape, the bremsstrahlung can be modeled via a constant line. The height of this line can be measured at spectral positions that are not populated by line emissions (e.g., between 665 nm and 667 nm). However, even though the bremsstrahlung can be accounted for by this method, high levels can significantly increase the photon noise in the spectra which can limit the analysis of the FIDA radiation. During ELMs, for example, the poloidal measurements are typically corrupted and the corresponding time intervals must be sorted out. B. Edge-D-alpha radiation In addition to the bremsstrahlung, the edge D-alpha emission line at 656.1 nm can be problematic for the measurements during ELM crashes. This component is one of the brightest line emissions of D-plasmas in the visible range. It is caused by electron impact excitation and by charge exchange reactions of deuterium neutrals and ions at the plasma edge and can routinely be monitored thanks to the interference filter in the spectrometer. The filter only attenuates the edge D-alpha line. It does not completely block it and its transmission properties can be taken into account in the diagnostic’s intensity calibration. As can be seen in Figure 5, the edge D-alpha radiation from the poloidal LOS is about 100 times more intense than that measured by the toroidal LOS. It has a non-Gaussian shape with a clear wing towards larger wavelengths. The origin of this wing is most likely due to Stark broadening which is caused by electric micro fields created by the high density of nearby charged particles. The more charge particles present, the larger the local electric fields, and the stronger the effective Stark splitting/broadening. The red line in Figure 5(b) shows the tabulated22 theoretical shape of the D-alpha line due to Stark and Doppler broadening, based on the model micro-field method (MMM).23 The predicted spectral shape has been convoluted with the diagnostic’s instrument function and corresponds to a neutral temperature of 3 eV which is close to the Franck Condon dissociation energy of recycled neutrals. The electron density needed to obtain good agreement between the measured and theoretical shape is 9 ×1020 m−3, which is relatively high compared to the values in the plasma center. However, electron densities of the order of 1021 m−3are observed in the divertor region during ELM crashes.24 The wing of the edge D-alpha line, measured by the poloidal LOS, reaches well above 659 nm. As will be discussed later, the FIDA radiation is analyzed in this wavelength range and the effect of Stark broadening could falsely be identified as a fast-ion contribution. Therefore, measurements in the presence of high electron densities must be avoided. However, it should be noted that the spectra from the toroidal and the MSE LOS are almost unaffected by high densities in the divertor region. This permits unperturbed measurements with these LOS also during edge-instabilities. C. Impurity line emissions As indicated in Figure 5, several impurity line emissions from the plasma edge are visible in the spectra of the FIDA diagnostic. The C II doublet at about 658 nm and the He I line emission at 667.8 nm are routinely observed with significant intensities. In addition, line emissions such as a N II line at 661.3 nm and an O II line at 664.1 nm can appear depending on the impurity content of the plasma. Compared to 30 May 2025 14:28:52 113502-5 Geiger et al. Rev. Sci. Instrum. 84, 113502 (2013) other machines like DIII-D,13 TEXTOR,12 or MAST,14 the level of passive impurity line emissions in ASDEX Upgrade plasmas is very low, which significantly facilitates the analysis of the FIDA radiation. This is in part due to the fully tungsten coated walls that yield a strongly reduced content of carbon and in part due to frequently applied boronizations that cover the walls with a thin layer of boron. Boron absorbs oxygen chemically and consequently decreases the impurity content. Boron itself does not emit radiation between 659 nm and 669 nm. D. D2 molecular lines D2molecular lines represent another possible contribution in the spectra (not visible Figure 5). They can be observed with the FIDA diagnostic during D2fueling from valves situated close to the LOS and exist over a wide range of wavelengths: The molecular lines correspond to transitions between various electronically excited levels. Due to the presence of vibrational and rotational sublevels in these electronic states, the emission spectrum shows a distinct vibro-rotational structure. Figure 6shows two spectra from a toroidal LOS that were measured during (black) and in the absence (gray) of D2 fueling. Clearly, a significant increase of the passive radiation is measured when D2is injected through valves located in the vicinity of the LOS. In orange, tabulated line intensities25 of the n=3→2 transitions of the D2triplet system are plotted where ndenotes the main quantum number of the electronic states in the united atom approximation.26 The corresponding theoretical spectrum that represents the sum of the single transitions, convoluted with the FIDA diagnostic’s instrument function, is shown in red. Its shape agrees well with the measurement and hence evidences the existence of the molecular lines. Since the D2lines are present across the whole spectrum, they would consequently be superimposed on the FIDA radiation. When performing dedicated fast-ion measurements it is therefore necessary to apply D2fueling from valves far from the diagnostic’s LOS. This guarantees almost D2linefree spectra. 658660 662 664 666 668 0 2•10 16 4•10 16 6•10 16 8•10 16 Ph/(s nm m 2 sr) Wavelength [nm] R: 1.708 [m]#27987 with D2 fuelling 5.90 - 5.98 s without D2 fuelling 6.20 - 6.28 s tabulated D2 spectrum n=3 -> 2, triplett FIG. 6. D2spectra from a toroidal LOS, measured with (black) and without (gray) D2fueling from a proximate valve. In orange, tabulated D2molecular lines25 are shown that correspond to n=3→2 transitions of the D2triplet system. E. Passive FIDA radiation As already explained in the Introduction, the FIDA radiation is emitted by fast deuterium ions after charge exchange reactions with neutrals. In particular, along NBI lines strong, core localized, active FIDA signals can be observed because NBI provides a neutral population in the plasma core with which the fast ions can charge exchange. Edge localized, passive FIDA radiation can, in contrast, only be observed when a significant part of the fast-ion population undergoes charge exchange reactions with neutrals from the plasma periphery. The passive FIDA radiation can therefore mainly be observed during off-axis NBI heating because this generates large offaxis fast-ion populations. The strongest passive FIDA signals, yet observed, are visible in the black spectra in Figure 7.The spectra were measured in discharge #28881 during off-axis NBI heating from a 93 keV source, labeled Q7. The measurement during off-axis NBI was clearly of passive nature since there is no overlap between the FIDA diagnostic’s LOS and the path of Q7. As sketched in Figure 1, NBI source Q7 belongs to box 2 which is displaced in the toroidal direction by 180◦, relative to box 1. The passive spectra are shown for two toroidal and two poloidal LOS that intersect NBI Q3 at different radial positions. A significant spectral contribution between 658 nm and 663 nm can be observed with maximum wavelength shifts that correspond to the NBI injection energy of 93 keV. This passive FIDA component can be seen best in the toroidal spectrum in Figure 7(c). The corresponding LOS is tangential to the edge-region and efficiently collects radiation from the passive FIDA emission layer. The passive radiation in the poloidal spectra (Figures 7(b) and 7(d)) is significantly weaker than that in the toroidal spectra (Figures 7(a) and 7(c)). First, the toroidal LOS are more sensitive to the passing fast ions generated by NBI Q7 (discussed in the following). Second, the fast-ion orbits are displaced relative to the flux surfaces radially outwards. Thereby, they encounter 1015 1016 1017 1018 Ph/(s nm m2 sr) 656 658660 662 664 1015 1016 1017 1018 Ph/(s nm m2 sr) Wavelength [nm] 656 658660 662 664 Wavelength [nm] poloidal R=1.981 [m] toroidal R=1.795 [m] toroidal R=1.988 [m] poloidal R=1.806 [m] Q3 (60 keV) Q7 (93 keV) Q3 (60 keV) Q7 (93 keV) Q3 (60 keV) Q7 (93 keV) Q3 (60 keV) Q7 (93 keV) OII FIDA FIDA FIDA CII CII CII CII BES BES BES (a) (b) (c) (d) passive FIDA passive FIDA 60 keV 93 keV FIDA FIG. 7. Passive spectra from two toroidal LOS (a) and (c) and two poloidal LOS (b) and (d) in black that were acquired during off-axis NBI heating. In gray, active spectra are plotted that were acquired during the operation of NBI Q3. 30 May 2025 14:28:52 113502-6 Geiger et al. Rev. Sci. Instrum. 84, 113502 (2013) large edge neutral densities close to the mid-plane. While the toroidal lines of sight intersect this region, the poloidal LOS do not. AsshowningrayinFigure7, the level of active radiation measured during the operation of NBI Q3 only is not significantly higher than that of the passive signal. In FIDA measurements during off-axis NBI heating, the passive contribution must consequently be taken into account. As modelling of the passive FIDA component is difficult (the edge neutral density is not well known), the passive FIDA light must be measured in phases when the diagnostic beam NBI Q3 is off. It can then, if necessary, be subtracted from the active signals. IV. ACTIVE RADIATION IN FIDA SPECTRA The active radiation is only present in FIDA spectra at ASDEX Upgrade during the operation of NBI Q3. Theoretically, it consists of three D-alpha components, i.e., the beam emission, the halo emission, and the FIDA emission, and of charge exchange radiation from impurities. The active line emissions from impurities are, however, not observed under standard experimental conditions. Only during plasmas in a poorly conditioned machine, a CVI(15 −11) line27 at 662.4 nm can be seen. In addition, an ArXVI(16 −15) line appears in the spectrum at 661.5 nm during dedicated argon seeding experiments. The three active D-alpha components are consequently the main active contributions. Their spectral shapes and origins will be discussed in this section using example spectra from a toroidal, a poloidal, and the MSE LOS. The example spectra, as plotted in Figure 9, are from a discharge that was heated by 5 MW of NBI power and featured a very low electron density (see Figure 8). This discharge was selected, not because the FIDA measurement exhibits particularly good signal to noise ratio (it is actually rather poor, e.g., compared to Figure 7), but because it was possible to analyze 0 1 2 T / MA 0 2 4 6 MW NBI power 0 2 4 10-19/m3 0.60 0.75 0.90 1.05 1.20 0 2 4 keV central electron temperature Time [s] Bt Ip Q3 (60 keV) Q8 (93 keV) electron density (line averaged) central ion temperature FIG. 8. Characteristic time-traces of discharge #29578. From top to bottom, the plasma current and magnetic field, the NBI heating power, the electron density, and the ion and electron temperatures are plotted. 650 655 660 665 1015 1016 1017 1018 1019 Ph/(s nm m2 sr) Wavelength [nm] R: 1.741 [m] 650 655 660 665 1015 1016 1017 1018 1019 Ph/(s nm m2 sr) Wavelength [nm] R: 1.795 [m]#[email protected] 650 655 660 665 1015 1016 1017 1018 1019 Ph/(s nm m2 sr) Wavelength [nm] R: 1.806 [m] FIDA BES HALO FIDA BES HALO (c) MSE (a) toroidal (b) poloidal FIDA BES HALO C II edge D-alpha edge D-alpha edge D-alpha bremsstrahlung bremsstrahlung bremsstrahlung σ π π FIG. 9. Measured spectra on a semi-logarithmic scale from a toroidal LOS (a), a poloidal LOS (b), and the MSE LOS (c). In addition, the theoretical beam, halo, and FIDA components predicted by FIDASIM are plotted. the redand blue-shifted sides of the spectrum. Due to the low plasma density, the diagnostic could be operated without interference filter and without saturation effects from the edge D-alpha line. In addition to the experimental data, Figure 9 shows theoretical spectra of the beam, halo, and FIDA radiation from FIDASIM28 which are plotted on top of the level of the bremsstrahlung, visible above 663 nm. FIDASIM is a Monte Carlo code that predicts the FIDA radiation that would be collected by an arbitrary LOS in the presence of a given theoretical fast-ion distribution function. The simulation uses atomic data, kinetic plasma profiles, the LOS geometry, and 30 May 2025 14:28:52 113502-7 Geiger et al. Rev. Sci. Instrum. 84, 113502 (2013) the energy, power, and geometry of the diagnostic beam. Additionally, it models the radiation from beam and halo neutrals. These two populations are needed to calculate the charge exchange probability of fast ions and, hence, are also simulated. As can be seen in Figure 9, the simulated components, which will be described in detail in the following, exhibit very good agreement with the measurement. A. Beam emission The simulated beam emission spectrum (BES) is displayed in Figure 9in orange/yellow. It originates from the injected deuterium neutrals that get excited as they move through the plasma and then emit D-alpha radiation. The beam emission only populates a well-defined part of the spectrum because the NBI generates neutrals with a narrowly focused velocity distribution that depends on the NBI geometry. Despite the high velocity of the injected neutrals, the observed wavelength shifts are relatively small, because the FIDA diagnostic’s LOS intersect NBI Q3 almost perpendicularly. The toroidal LOS intersect NBI Q3 with angles of about 75◦and measure red-shifted beam emission. The poloidal LOS have angles to the NBI path between 80◦in the center and 110◦ close to the plasma edge and measure the beam emission from slightly red-shifted to slightly blue-shifted, respectively. The MSE LOS points anti-parallel to the NBI path and, therefore, observes blue shifted beam emission. The spectral shape of the beam emission depends on the NBI source’s species mix, i.e., the injection of neutrals with the full, half, and one third energy (shown with colors from yellow to orange) and on the Stark effect. The latter is imposed by the strong v×Belectric fields experienced by the neutrals and causes a splitting of each energy component into roughly one un-shifted σ(perpendicular to the electric field) and two shifted π(parallel to the electric field) lines, as indicated in Figure 9(a) for the full energy component. In addition to the theoretical ratio of the intensities of the sigma σand π lines, the optical components of the diagnostic transmit this polarized light with different intensities. The toroidal LOS of the FIDA diagnostic, for example, do not transmit the σand πcomponents equally but with a ratio of ≈0.9 due to the use of a mirror in the light path. The absolute intensity of the beam emission and its radial dependence are mainly linked to plasma density. The higher the density is, the more injected neutrals get excited when entering the plasma and the higher the levels of the beam emission measured by LOS close to the plasma edge are. In the plasma center, in contrast, higher plasma densities yield reduced levels of the beam emission as the injected neutrals are more efficiently attenuated and fewer reach the plasma core. Here, it should be noted that the measurement of the beam emission is very important for the proper analysis of the FIDA radiation. When comparing the measured FIDA signals to modelling results from FIDASIM, the beam emission can be used to validate, e.g., the electron density profiles used in the simulation. The density of injected beam neutrals, and hence also the simulated FIDA component can only be trusted if the simulated beam emission agrees with the measurement. B. Halo emission In addition to the beam emission, also the halo emission should be used to validate the modelling results. The halo emission, as plotted in green in Figure 9, is emitted by a cloud of thermal deuterium neutrals that is present along the NBI path and which contributes, in large part, to the charge exchange signal from fast ions. The so-called halo neutrals themselves also originate from charge exchange reactions between thermal deuterium ions and the injected beam neutrals, as well as with other halo neutrals. The spectral shape of the halo component can be approximated by a Gaussian curve whose width and position are linked to the ion temperature and rotation. Depending on these two quantities, the wings of the halo component can extend to relatively large wavelength shifts in the spectra. However, for wavelengths above 659 nm and below 653 nm, the halo radiation is negligible under standard conditions, such as temperatures below 6 keV and plasma rotations below 250 km/s. The intensity of the halo emission is linked to the beam neutral density but also depends on the impurity content of the plasma. The higher the impurity content, the lower the deuterium density. Hence, there are fewer D-ions present that can be neutralized and fewer thermal neutrals emit D-alpha light. C. FIDA emission The red curves in Figure 9show the simulated FIDA radiation which is based on a TRANSP29 predicted slowing down distribution function of fast ions. The corresponding velocity space distribution at about R=1.81 m is plotted in Figure 10 as a function of energy and pitch where pitch =v||/v, with v|| the fast-ion velocity anti-parallel to the magnetic field lines, pointing into the co-current direction (see Figure 1). The displayed velocity distribution is a good representation for ASDEX Upgrade since all of the eight available NBI sources are tilted into the co-current direction and hence primarily generate co-rotating fast ions. The beam-ion distribution functions in ASDEX Upgrade are consequently asymmetric in the pitch direction and have maximums close to 0.5. The plotted velocity space exhibits energies up to 93 keV because discharge #29578 was heated by a 93 keV NBI source in addition to the 60 keV NBI source Q3. Due to these relatively large energies, in combination with a broadening of the distribution function in the pitch range due to collisions and different fast-ion deposition locations, the FIDA radiation can be observed at wavelengths above the beam and halo emissions. In Figure 9, the measured and simulated FIDA components are clearly not overlaid below 653 nm and above 659 nm. This makes the analysis of fast ions in these regions possible. The parts of the fast-ion velocity space that are observed at these wavelengths depend on the viewing geometries. As an example, Figure 11 shows synthetic FIDA spectra of two different artificial velocity space distributions for the three viewing geometries. The velocity distribution used to calculate the spectra in Figure 11(a) is highlighted by a red box in Figure 10. It consists of fast-ion energies between 50 keV and 60 keV and of pitches between 0.8 and 1.0 and hence represents passing fast ions that move in the co-current direction. Clearly, 30 May 2025 14:28:52 113502-8 Geiger et al. Rev. Sci. Instrum. 84, 113502 (2013) 0 20 40 60 80 100 -1.0 -0.5 0.0 0.5 1.0 Pitch Energy [keV] 0.0 0.4 0.8 1.2 1.5 1.9 1017 fast-ions/(m3 keV pitch) simulated by TRANSP #[email protected] s R = 181 cm FIG. 10. TRANSP predicted velocity space distribution of fast ions in ASDEX Upgrade generated by NBI Q3 and a second 93 keV heating beam in discharge #29578 at 1.05 s. only the toroidal LOS and the MSE LOS are able to measure these ions well at wavelengths below 653 nm and above 659 nm because such Doppler shifts are only observed when fast ions move parallel or anti-parallel to the LOS. Since the LOS have well defined angles to the magnetic field lines, parallel moving fast ions have explicit pitch values as well. Fast ions that propagate parallel to the toroidal LOS have pitches of cos(12◦)=0.98. Those propagating anti-parallel to the MSE LOS have pitches of cos(180◦−157◦)=0.92. In the toroidal spectra, the simulated fast ions with pitches between 0.8 and 1.0 consequently cause strongly red-shifted FIDA radiation. In the MSE spectrum, strongly blue shifted radiation is observed from these ions. When, in contrast simulating spectra for a fast-ion velocity distribution with pitch values between −0.1 and 0.1 (orange box in Figure 10) only the poloidal spectrum exhibits wavelengths below 653 nm and above 659 nm, as shown in Figure 11(b). Fast ions with pitches close to zero move almost parallel or anti-parallel to the poloidal LOS and hence cause large Doppler shifts (the largest Doppler shifts would be expected from fast ions with pitch values of cos(70◦)=0.34). An alternative method to illustrate the dependence between the measured wavelength shifts and the observed parts of the fast-ion velocity space is provided by so called diagnostic weight functions. A grid of example weight functions for three LOS and for three wavelength intervals is shown in Figure 12. For a defined wavelength interval and LOS, the weight functions provide the number of photons that would be detected from a single fast ion in a given pitch and energy range. They account for the charge exchange probability of the fast ions, for the photon emission probability, and for the Doppler shift and Stark splitting. According to the weight functions shown in Figures 12(d)–12(f), the poloidal LOS are sensitive to fast ions with pitch values close to zero, i.e., trapped fast ions. They cover a wide range of pitches for blue-shifted (Figure 12(d)) and red-shifted (Figures 12(e) and 12(f)) wavelengths. The toroidal and the MSE LOS, in contrast, cover more narrow ranges in the pitch space. They show a roughly symmetric behavior in pitch with opposite signs. At 650 652 654 656 658660 662 664 Wavelength [nm] 1013 1014 1015 Ph/(s nm m2 sr) (b) energy range: 50 - 60 keV pitch range: -0.1 - 0.1 650 652 654 656 658660 662 664 Wavelength [nm] 1013 1014 1015 Ph/(s nm m 2 sr) pitch range: 0.8 - 1.0 MSE (a) energy range: 50 - 60 keV toroidal poloidal MSE toroidal poloidal FIG. 11. Synthetic FIDA spectra observed by a toroidal (blue), poloidal (purple), and the MSE (green) LOS for the two artificial fast-ion distributions sketched in Figure 10 in red and orange. (a) Spectra for pitches between 0.8 and 1.0. (b) Spectra for pitches between −0.1 and 0.1. the blue shifted side of the spectrum, the toroidal LOS is sensitive to counter-rotating fast ions while the MSE LOS measures co-rotating fast ions and vice versa for the red-shifted side. To illustrate the parts of the velocity space that can actually be investigated in NBI-heated plasmas in ASDEX 0 50 100 keV -1 0 1 pitch g) -1 0 1 pitch d) -1 0 1 pitch a) 652 - 653 nm 50 100 keV h) e) b) 659 - 660 nm 50 100 keV i) f) c) 660 - 661 nm 0.0 1.4 2.8 4.2 5.7 7.1 101ph cm/(s fast-ion keV pitch) toroidal poloidal MSE FIG. 12. Weight functions for a (a)–(c) toroidal, (d)–(f) poloidal, and the (g)–(i) MSE LOS for three different wavelength ranges. Depending on the wavelength, the LOS access different parts of the fast-ion velocity space. 30 May 2025 14:28:52 113502-9 Geiger et al. Rev. Sci. Instrum. 84, 113502 (2013) 0 50 100 keV -1 0 1 pitch (g) -1 0 1 pitch (d) -1 0 1 pitch (a) 652 - 653 nm 50 100 keV (h) (e) (b) 659 - 660 nm 50 100 keV (i) (f) (c) 660 - 661 nm 0.0 1.0 1.9 2.9 3.9 4.8 1015ph/(s m2 sr nm keV pitch) toroidal poloidal MSE FIG. 13. (a)–(i) Product of the fast-ion velocity distribution shown in Figure 10 with the weight functions displayed in Figure 12. Upgrade, Figure 13 shows the product of the weight functions and the representative fast-ion velocity distribution, displayed in Figure 10. This product yields the number of photons/(s sr nm m2) that would be observed by a given LOS in a set wavelength range as a function of energy and pitch. With the individual LOS and wavelength ranges, distinct parts of the velocity space are clearly measured. This allows, for example, the effect of sawtooth crashes30 on the different parts of the velocity space, to be investigated. In addition, the acquisition of FIDA spectra with multiple viewing geometries, as presented here, will open up the possibility to infer 2D velocity-space distribution functions from the spectra by tomographic inversion in velocity space as presented in Refs. 31,32. D. Time traces and radial profiles of the FIDA light The FIDA diagnostic’s exposure time of 2 ms permits the analysis of the evolution of measured FIDA intensities with good temporal resolution. FIDA intensities measured by each LOS can be calculated by integrating the spectra in wavelength and by modelling the background radiation with a flat line. The height of this flat line, representing the bremsstrahlung, can be derived from parts of the spectra which are free from line radiation. The FIDA intensities depend on the fast-ion distribution and on the density of beam and halo neutrals along the path of NBI Q3. If this density can be assumed to be constant in time, the changes of the FIDA intensity can already indicate changes of the fast-ion confinement. Figures 14(a) and 14(b) show FIDA intensities from three LOS and for two different wavelength integration ranges, measured in discharge #29578. The FIDA radiation appears after NBI Q3 is turned on at about 0.8 s and increases further at 1.0 s when the second NBI source, Q8, is added. The data in Figure 14(a) correspond to the wavelength range between 652 nm and 653 nm and hence represent the regions of the velocity space displayed in Figures 12(a), 12(d), and 12(g). While the MSE LOS measures strong levels of the FIDA radiation, the poloidal LOS measures weak 0.7 0.80.9 1.0 1.1 1.2 Time [s] 0 1 2 3 4 5 1016Ph/(s m2 sr) 0.7 0.80.9 1.0 1.1 1.2 Time [s] 0 1 2 3 4 5 1016Ph/(s m2 sr) (a) 652 nm - 653 nm (b) 660 nm - 661 nm toroidal poloidal MSE toroidal poloidal MSE FIG. 14. Temporal evolution of the FIDA intensities for three LOS and two wavelength ranges (a) and (b). levels and the toroidal almost nothing. This is well explained by Figures 13(a),13(d), and 13(g), which show the overlap of the corresponding weight function with the fast-ion velocity space. However, it should be noted that the velocity space distribution used to calculate the overlap in Figure 13 only corresponds to one time point at 1.05 s in the analyzed discharge. It, for example, does not exactly describe the velocity space when only fast ions from the 60 keV source are present and, hence, only gives a rough estimate. The time traces of the FIDA signal in Figure 14(b) correspond to fast ions with energies above 30 keV because an integration range between 660 nm and 661 nm has been used. In this integration range, the toroidal and poloidal LOS measure similar intensities while the velocity space observed by the MSE LOS clearly has no significant overlap with the fast-ion distribution function. In addition to the analysis of time traces, the FIDA intensities per LOS can be used to analyze radial profiles. As an example, Figure 15 shows radial profiles from the toroidal LOS (solid line) and from the poloidal LOS (dashed line) that represent the FIDA radiation between 660 nm and 661 nm. The profiles exhibit different spectral shapes as different regions in the velocity space are observed. The error bars of the data represent two sigma of the scatter of the FIDA data which have been averaged over a time interval of 8 ms. In future experiments, the analysis of radial profiles will provide, for example, better insight into the current drive capabilities of the off-axis NBI sources.33 30 May 2025 14:28:52