applied sciences Article The Radioactivity of Thorium Incandescent Gas Lantern Mantles Halmat Jalal Hassan 1,2 , Suhairul Hashim 1,3,* , Mohamad Syazwan Mohd Sanusi 1, David Andrew Bradley 4,5, Abdullah Alsubaie 6, Rafael Garcia Tenorio 7,8, Noor Fitriah Bakri 9and Rozman Mohd Tahar 9 Citation: Hassan, H.J.; Hashim, S.; Sanusi, M.S.M.; Bradley, D.A.; Alsubaie, A.; Tenorio, R.G.; Bakri, N.F.; Tahar, R.M. The Radioactivity of Thorium Incandescent Gas Lantern Mantles. Appl. Sci. 2021,11, 1311. https://doi.org/10.3390/app11031311 Received: 11 December 2020 Accepted: 28 January 2021 Published: 1 February 2021 Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. Copyright: © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/). 1Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, Johor 81310, Malaysia; [email protected] (H.J.H.); [email protected] (M.S.M.S.) 2Department of Physics, College of Education, University of Sulaimani, Sulaimani 46001, Iraq 3Ibnu Sina Institute for Scientific and Industrial Research (ISISIR), Universiti Teknologi Malaysia, Johor 81310, Malaysia 4Centre for Applied Physics and Radiation Technologies, Sunway University, Selangor 47500, Malaysia;
[email protected] 5Department of Physics, University of Surrey, Guilford GU2 7XH, UK 6Department of Physics, Taif University, P.O. Box 11099, Taif 21944, Saudi Arabia; [email protected] 7Department of Applied Physics II, ETSA, University of Seville, 41003 Seville, Spain; [email protected] 8Centro Nacional de Aceleradores, CNA, University of Seville-J. Andalucía-CSIC, 41092 Seville, Spain 9Atomic Energy Licensing Board, Selangor 43800, Malaysia; [email protected].my (N.F.B.); [email protected].my (R.M.T.) *Correspondence: suhair[email protected]; Tel.: +60-13-7564706 Abstract: The use of thorium in providing the intense white luminescence emitted from gas mantles, has a history of some 130 years, the initial application pre-dating by several decades large-scale urban electric lighting. Accordingly, the thoriated gas mantle has proved itself to be of enormous utility, remaining popular in more rural areas well into the 20th century, continuing to enjoy use in campsites and street night markets lanterns until today. The discovery of thorium in 1828 preceded the discovery of radioactivity, with subsequent little appreciation initially of any potential harm from exposure to radioactivity. Study has been made herein of small quantities of five different types of the thoriated gas mantle, all purchased online devoid of any control measures. Several approaches were used concerning the 232 Th activity and dose consequence. First, the activity of 232 Th was estimated using an HPGe detector, with sample M5 providing the greatest activity at 1.25 × 10 4 Bq, exceeding the exemption limit for thorium in a mantle. Compared to sample M5, samples M1 to M4 were low in radioactivity, from 5.1 ± 1.31 to 16.33 ± 1.92 Bq. Moreover, the thorium content in M5 constituted 50% of the mantle mass, somewhat greater than previous literature values. The dose equivalent rate on the surface of a single M5 mantle was found to be 0.68 µ Sv/h, while at the surface of a pack of six the level was 1.9 µ Sv/h. Monte Carlo simulation codes have been used to obtain organ equivalent and effective dose rates, the greatest close contact (10 cm) exposure to an unlit mantle being to the thymus, at 0.68 µ Sv/h and 0.62 µ Sv/h for a male and female phantom respectively. Accordingly, with packages of thoriated gas mantles potentially giving rise to non-negligible equivalent doses, greater incorporation of controls on the sale of such items in national radiation protection legislation would seem worthy of consideration. Keywords: gas lantern mantle; radioactive consumer products; Monte Carlo simulation 1. Introduction Since 1885, gas lantern mantles containing the unstable element thorium have been used for indoor and outdoor lighting, thoriated gas mantles producing intense white light luminescence [ 1 , 2 ]. Typically in the manufacture of thoriated gas lantern mantles, rayon fibers are dipped into a nitrate solution formed of an active component containing 99% thorium and 1% cerium [ 3 ]. On pre-burning of the gas mantle, the thorium and cerium in the mantle are transferred to thorium oxide and cerium oxide, providing the basis of the brilliant white light emission at burn temperatures [4–7]. Appl. Sci. 2021,11, 1311. https://doi.org/10.3390/app11031311 https://www.mdpi.com/journal/applsci
Appl. Sci. 2021,11, 1311 2 of 11 Thoriated gas lantern mantles are considered radioactive consumer products, NORM (Naturally Occurring Radioactive Materials) added. NORM are radioactive materials that can be found in nature, primarily the primordial radionuclides 238 U, 232 Th and 40 K [ 8 ]. The thorium content in the mantle represents a potential hazard from exposure to ionizing radiation [ 8 ]. A number of researchers have studied the radiation risk arising from the thorium contained in lantern mantles [ 9 – 12 ], Furuta, Yoshizawa [ 7 ] finding no differences in brightness in the use of thoriated gas mantles and competitor non-radioactive mantles. Even so, the thoriated mantle finds continued use in many countries, typically in the absence of any radioactive information on the mantle packing. Among the purveyors of such items little effort seems to be made in indicating the availability of choice between the use of thoriated and non-thorium based mantles. From a review of the literature concerning consumer products containing radioactive substances in the European Union, Shaw et al. [ 13 ] reported that in much of the developed world the sale of the radioactive gas mantle is either prohibited or subjected to licensing. As instances, European states prohibiting the importation of thoriated mantles include the Netherlands, Italy, Greece, and Switzerland [ 13 ]. Conversely, in Sweden, Denmark, Spain, Lithuania, and Norway, mantles are subject to licensing by regulatory bodies, the activity of thorium potentially exceeding the exemption limit 1 kBq [ 14 – 16 ]. In Germany and Finland, radioactive mantles are available to the public [ 13 ], a situation also found elsewhere, such as in Malaysia where thoriated gas mantles are freely available without control, including lack of demand for testing, handling, and disposal. Nowadays, gas lantern mantles are usually used in rural areas and for camping and night markets, as night lights [ 16 , 17 ]. In Malaysia, the country of the present study, many types of the mantle are available for purchase online, also being widely used. In regard to radiation risks to health, as a minimum, it would seem necessary to make an evaluation of the thorium content in these types of mantle, also assessing the risk to users and sellers of these items. The gamma-radiation emitted from the mantles and the possible inhalation or ingestion of the fine thorium oxide powder during replacement operations could represent a health hazard for regular users [6]. The present study seeks to investigate the thorium content of gas lantern mantles currently available in the Malaysian market. We have also performed radiometric characterization and analysis, examining radiological implications arising from contact with packaged thoriated gas mantles. In particular, such risks might be assumed to be greatest for purveyors storing these items in bulk amounts. The research includes estimating organ equivalent and effective dose rates, values obtained through the use of Monte Carlo simulation. Given the absence of Malaysian regulations on NORM, with gas mantles being sold devoid of details of the level of radionuclide, this study also seeks to influence the existing radiation protection guideline document (LEM/TEK/69) established by the Atomic Energy Licensing Board (AELB) [ 18 ], the particular document having the intent to address such issues. 2. Materials and Methods 2.1. Sampling Via the online market, five types of the thoriated mantle were purchased, the mantles packaging providing no information concerning the radionuclide content within (see, for instance, Figure 1). In some cases, the mantles are sold in bulk in the absence of packaging. The samples were classified into five batches according to manufacture batch numbers. Two samples from each batch number were subjected to investigation. The three methods of investigation used were as depicted in (Figure 2): Direct, immersed in nitric acid, and measurement of the residual ash following burning for 1 h.
Appl. Sci. 2021,11, 1311 3 of 11 Appl. Sci. 2021, 11, x FOR PEER REVIEW 3 of 11 2. Materials and Methods 2.1. Sampling Via the online market, five types of the thoriated mantle were purchased, the mantles packaging providing no information concerning the radionuclide content within (see, for instance, Figure 1). In some cases, the mantles are sold in bulk in the absence of packaging. The samples were classified into five batches according to manufacture batch numbers. Two samples from each batch number were subjected to investigation. Figure 1. Front side packing of the thoriated gas mantle. The three methods of investigation used were as depicted in (Figure 2): Direct, immersed in nitric acid, and measurement of the residual ash following burning for 1 h. Figure 2. Three methods of mantle sample investigation: Direct; immersed in nitric acid; burned for 1 h. 2.2. Direct Measurement of Thorium Daughters, Using HPGe γ-Spectrometry Individual samples of each of the five types of gas lantern mantle were carefully weighed to a sensitivity of 1 mg, sample masses being within the range 1.320 to 3.490 g, obtaining representative mass evaluations. Using a well-shielded high purity germanium Figure 1. Front side packing of the thoriated gas mantle. Appl. Sci. 2021, 11, x FOR PEER REVIEW 3 of 11 2. Materials and Methods 2.1. Sampling Via the online market, five types of the thoriated mantle were purchased, the mantles packaging providing no information concerning the radionuclide content within (see, for instance, Figure 1). In some cases, the mantles are sold in bulk in the absence of packaging. The samples were classified into five batches according to manufacture batch numbers. Two samples from each batch number were subjected to investigation. Figure 1. Front side packing of the thoriated gas mantle. The three methods of investigation used were as depicted in (Figure 2): Direct, immersed in nitric acid, and measurement of the residual ash following burning for 1 h. Figure 2. Three methods of mantle sample investigation: Direct; immersed in nitric acid; burned for 1 h. 2.2. Direct Measurement of Thorium Daughters, Using HPGe γ-Spectrometry Individual samples of each of the five types of gas lantern mantle were carefully weighed to a sensitivity of 1 mg, sample masses being within the range 1.320 to 3.490 g, obtaining representative mass evaluations. Using a well-shielded high purity germanium Figure 2. Three methods of mantle sample investigation: Direct; immersed in nitric acid; burned for 1 h. 2.2. Direct Measurement of Thorium Daughters, Using HPGe γ-Spectrometry Individual samples of each of the five types of gas lantern mantle were carefully weighed to a sensitivity of 1 mg, sample masses being within the range 1.320 to 3.490 g, obtaining representative mass evaluations. Using a well-shielded high purity germanium (HPGe) spectrometer, each mantle was then counted for a period of 86,400 s (24 h). In detail, each mantle was firmly located within the shielded arrangement, in a holder coaxially aligned with and 3 cm above the top cap of the HPGe detector. This geometrical configuration was maintained for all unburned and burned mantles. The gamma emission from samples was directly measured using an ORTEC GEM Series P-type coaxial HPGe spectrometer (GEM20-76-LB-C-SMPCFG-SV-LB-76; 33% relative efficiency; 1.8 keV FWHM at 1332 keV). This provides for high-performance gamma spectroscopy over the energy range 40 keV up to several MeV. The system, equipped with a Mobius cooling system, also uses high-resolution gamma spectroscopy software (VISION version 8) for spectral analysis of the gamma emission.
Appl. Sci. 2021,11, 1311 4 of 11 The spectra, collected over 16,380 channels, were calibrated with a 152 Eu standard point source, providing a wide range of photon energies (121.78, 244.6, 344.3, 411.1, 778.9, 867, 964, 1112, and 1528 keV). The counting efficiencies of the 232 Th series under these measurement conditions was 1.56% for 212 Pb (238.4 keV), 1.26% for (338.2 keV), 0.44% for 228 Ac (911 keV), 0.61% for 212 Bi (727 keV), 0.75% for (583 keV), 0.17% for 208 Tl (2614 keV), all the energy lines having high emission probabilities of decay gamma rays emitted by the radionuclides [ 19 ]. The radioactivity in the mantles were estimated by measuring gamma-ray emissions from the thorium daughters, comprising 228 Ra estimated from the average of the results of both gamma lines of 228 Ac (338 keV and 911 keV), 228 Th estimated from the average of the resulting gamma lines of 212 Pb (238 keV) and 212 Bi (727 keV); also 208Tl (583 keV and 2614 keV), with 232Th estimated from the average of 228Ra and 228Th. 2.3. Mantles Immersed in HNO3and Distilled Water For this, each mantle was immersed in 50 mL of fresh warm 0.5 M HNO 3 , subsequently stirred for 10 min using a hot plate stirrer operating on the basis of a Teflon coated magnet. Through decantation, the leach solution in each case was transferred to a volumetric flask. The leaching process was repeated using distilled water instead of HNO 3 . The leach solution was then combined with the previous HNO 3 leach solution [ 17 ]. To thoroughly leach the radioactivity from the mantle, both the HNO 3 and distilled water leaching processes were repeated three times. The mantles were then removed. The combined leaching solution, diluted to 500 mL and transferred into a 500 mL Marinelli beaker, was then measured by an HPGe detector for 86,400 s as previously described. To allow for secular equilibrium, 228Ra and 228Th were measured after 30 days of storage. In regard to a test of manufacturing quality, as required in Indian regulations [ 20 ], two unused gas mantles, were immersed in beakers of distilled water maintained at 50 ◦ C through the use of a hot plate, being held at this temperature for 5 h. The mantles were then removed and the radioactivity released into water measured. 2.4. Burned Gas Lantern Mantle For this, the mantle was placed in a lantern and pre-burned for 1 h. The residual ash was then carefully extracted from the lantern and counted for 2 h using the HPGe detector. To estimate the amount of radioactivity in the vapor produced by the mantles during burning, the mantles were measured before burning and 1 h after burning. Further, to observe the build-up of daughter nuclides, the residual ash was investigated 4-, 168-, 240-, and 720 h after burning. 2.5. Characterization of Gas Lantern Mantle For elemental content, the lantern mantles were analysed using an inductively coupled plasma optical emission spectroscopy facility (ICP-OES, Avio 200, PerkinElmer, Waltham, MA, USA), in particular obtaining the amount of thorium in the mantle. For this, 1 g of each mantle was transferred into a microwave digestion vessel to which was then added 10 mL of conc. HNO 3 65% and 5 mL of H 2 O 2 30%, then heated to 150 ◦ C in a microwave oven to digest the sample. The mixture was evaporated to near dryness, the completely dissolved sample then being transferred quantitatively to a volumetric flask and diluted to 25 mL using ultra-pure water (UPW). Each dissolved sample was then analyzed via use of the ICP-OES facility, the procedure being in accord with manufacturer-defined procedures [ 7 ]. 2.6. Monte Carlo (MC) Simulation and Evaluation of Effective Dose (ED) Here one seeks organ dose conversion factors (DCFs), estimating organ equivalent doses from gas lantern mantle radiation exposure [ 21 – 23 ]. For this, a series of simulations were undertaken involving the five main series of gamma photons from 232 Th, use being made of the Monte Carlo N-Particle radiation transport code, version MCNP5 (Los Alamos National Laboratory), also involving medical internal radiation dose (MIRD) mathematical phantoms, male and female (Figure 3) (male phantom 178 cm tall, weight 91 kg; female
Appl. Sci. 2021,11, 1311 5 of 11 phantom 168 cm and 72 kg). The mantle was taken to be a sphere of 4 cm diameter. In evaluations the mantle M5 was located at 10, 20, 50, and 100 cm separation from the chest in order to estimate the effective dose. Further to this, organ equivalent doses for 21 organs of the male and female phantom were obtained, with the mantle simulated at 20 cm from the chest. Appl. Sci. 2021, 11, x FOR PEER REVIEW 5 of 11 wave oven to digest the sample. The mixture was evaporated to near dryness, the completely dissolved sample then being transferred quantitatively to a volumetric flask and diluted to 25 mL using ultra-pure water (UPW). Each dissolved sample was then analyzed via use of the ICP-OES facility, the procedure being in accord with manufacturer-defined procedures [7]. 2.6. Monte Carlo (MC) Simulation and Evaluation of Effective Dose (ED) Here one seeks organ dose conversion factors (DCFs), estimating organ equivalent doses from gas lantern mantle radiation exposure [21–23]. For this, a series of simulations were undertaken involving the five main series of gamma photons from 232 Th, use being made of the Monte Carlo N-Particle radiation transport code, version MCNP5 (Los Alamos National Laboratory), also involving medical internal radiation dose (MIRD) mathematical phantoms, male and female (Figure 3) (male phantom 178 cm tall, weight 91 kg; female phantom 168 cm and 72 kg). The mantle was taken to be a sphere of 4 cm diameter. In evaluations the mantle M5 was located at 10, 20, 50, and 100 cm separation from the chest in order to estimate the effective dose. Further to this, organ equivalent doses for 21 organs of the male and female phantom were obtained, with the mantle simulated at 20 cm from the chest. Figure 3. Medical internal radiation dose (MIRD) human phantoms and juxtaposition of lantern mantle M5, color represent different composition and density of tissues; green, yellow, and aqua represent lung tissue, soft tissue, and bone, respectively. 3. Results and Discussion 3.1. Measurements of 232 Th Activity in Gas Mantle The activity of thorium was investigated for the five different types of mantle (masses 1.320 to 3.490 g), with 232 Th activity ranging from 5.1 ± 1.31 to 16.33 ± 1.92 Bq/mantle. Samples M1 to M4 were low in radioactivity, compared to mantles M5 which recorded a relatively high 232 Th activity, at 12,517 ± 1173 Bq/mantle (Table 1). In addition, the activity of thorium in samples M5 exceeds guidance on an exemption limit of 1 × 10 3 Bq for Th-232, as in the international basic safety standards for protection against ionizing radiation IAEA [24], also in update IAEA 2014 GSR Part 3 [15] of 1 × 10 4 Bq. Shabana et al. [17] suggest the update links to research showing many mantles exceeding prior guidance, with for instance the authors obtaining 4.5 × 10 3 Bq of Th-232 in mantles, also with the U.K. the National Radiological Protection Board (NRPB-R263) proposing a limit of radioactive thorium of not more than 1 kBq per mantle [25]. Figure 3. Medical internal radiation dose (MIRD) human phantoms and juxtaposition of lantern mantle M5, color represent different composition and density of tissues; green, yellow, and aqua represent lung tissue, soft tissue, and bone, respectively. 3. Results and Discussion 3.1. Measurements of 232Th Activity in Gas Mantle The activity of thorium was investigated for the five different types of mantle (masses 1.320 to 3.490 g), with 232 Th activity ranging from 5.1 ± 1.31 to 16.33 ± 1.92 Bq/mantle. Samples M1 to M4 were low in radioactivity, compared to mantles M5 which recorded a relatively high 232 Th activity, at 12,517 ± 1173 Bq/mantle (Table 1). In addition, the activity of thorium in samples M5 exceeds guidance on an exemption limit of 1 × 10 3 Bq for Th-232, as in the international basic safety standards for protection against ionizing radiation IAEA [ 24 ], also in update IAEA 2014 GSR Part 3 [ 15 ] of 1 × 10 4 Bq. Shabana et al. [ 17 ] suggest the update links to research showing many mantles exceeding prior guidance, with for instance the authors obtaining 4.5 × 10 3 Bq of Th-232 in mantles, also with the U.K. the National Radiological Protection Board (NRPB-R263) proposing a limit of radioactive thorium of not more than 1 kBq per mantle [25]. Table 1. Activity of radionuclides of the Th-232 series in different types of the mantle. Sample Weight (g) Activity ±1 Sigma (Bq/Mantle) Ra-228 Th-228 Th-232 * M1 Butterfly ART No.4D (500-600 C.P.) 2.79 ±0.0027 14.11 ±2.2 12.5 ±1.35 13.3 ±1.77 M2 Kovea KL 101/102 -TKL929 1.42 ±0.0014 6.65 ±0.6 8.6 ±1.2 7.62 ±0.9 M3 U-shape ** 1.32 ±0.0013 4.7 ±0.73 5.5 ±1.9 5.1 ±1.31 M4 Kovea TKL-N894 KL103 1.75 ±0.0017 14.11 ±2.24 18.56 ±1.6 16.33 ±1.92 M5 Butterfly No.999 (300-400 C.P.) 3.49 ±0.0034 13,393 ±1398 11,642 ±948 12,517 ±1173 * Activity of Th-232, averaged from Ra-228 and Th-228. ** Name of manufacturer and model not available on the mantle package.
Appl. Sci. 2021,11, 1311 6 of 11 Present study results as in (Table 1), are comparable to the literature review data in (Table 2), in the case of M5 recording a value greater than that of the previous data. Table 2. Activity of radionuclide Th-232 in the gas mantle. Literature data and data from this study. No. Th-232 (Bq/Mantle) Reference 1 0.56–4.8 [4]—Iran 2 2411 [5]—US 3 247 [6]—Netherland 4 750–1800 [10]—Italy 5 248–893 [12]—Kingdom of Saudi Arabia 6 483–2025 [11]—Kingdom of Saudi Arabia 7 350–4560 [17]—Kingdom of Saudi Arabia 8 1410 [7]—Japan 9 1000 [13]—Norway 10 500–4000 [13]—Germany 11 795–1054 [14]—Austria 12 1386–1963 [16]—Spain 13 5.1–12,517 Present study—Malaysia Results from pristine M5 mantles prepared using two different methods (Table 3) showing the activity of Th-232 obtained in direct measurement of the gamma-ray spectrum from ‘as is’ samples to be comparable to within 11% with that from mantles dissolved in 0.5 M HNO3, indicative of a good degree of efficiency in thorium released into solution. Table 3. Activity of radionuclides from the Th-232 series in mantle M5. Sample Activity ±1 Sigma (Bq/Mantle) Ra-228 Th-228 Th-232 * Pristine mantle 13,252 ±1385 11,325 ±875 12,288 ±1130 13,534 ±1411 11,959 ±1021 12,746 ±1216 Average 13,393 ±1398 11,642 ±948 12,517 ±1173 Mantle dissolved in 0.5 M HNO3 11,853 ±751 10,646 ±506 11,249 ±62 11,432 ±822 10,734 ±511 11,083 ±667 Average 11,642 ±787 10,690 ±499 11,166 ±643 * Activity of Th-232, averaged from Ra-228 and Th-228; Name of manufacturer and model not available on the mantle package. 3.2. Build up Daughter Nuclides To estimate the amount of radioactivity vaporizing in the burning of the mantles, gamma emissions from the mantles were measured before and after burning, with results recorded in Figure 4; zero-hour represents the unburned mantle while the 1, 4, 168, 240, and 720 h temporal points represent the time delays between initial and post-burn measurements. Subsequent to the initial ignition and termination period, daughter nuclides fractional evaporation is observed, detected at the first-hour temporal point, the initial concentrations of 212 Pb (t 1/2 10.6 h), 212 Bi (t 1/2 1.01 h), and 208 Tl (t 1/2 3.05 m) decreasing by 30%, 37% and 43%, respectively. At 168 h, the build-up of the daughter nuclides restores the initial concentrations, the residual ash retaining the greater thorium fraction. The result accord with previous studies of Luetzelschwab and Googins [ 5 ] and Al-Jarallah et al. [ 11 ] and Furuta et al. [ 7 ], each concluding that thorium is subject to minimal evaporation during burning.
Appl. Sci. 2021,11, 1311 7 of 11 Appl. Sci. 2021, 11, x FOR PEER REVIEW 7 of 11 3.2. Build up Daughter Nuclides To estimate the amount of radioactivity vaporizing in the burning of the mantles, gamma emissions from the mantles were measured before and after burning, with results recorded in Figure 4; zero-hour represents the unburned mantle while the 1, 4, 168, 240, and 720 h temporal points represent the time delays between initial and post-burn measurements. Subsequent to the initial ignition and termination period, daughter nuclides fractional evaporation is observed, detected at the first-hour temporal point, the initial concentrations of 212Pb (t1/2 10.6 h), 212Bi (t1/2 1.01 h), and 208Tl (t1/2 3.05 m) decreasing by 30%, 37% and 43%, respectively. At 168 h, the build-up of the daughter nuclides restores the initial concentrations, the residual ash retaining the greater thorium fraction. The result accord with previous studies of Luetzelschwab and Googins [5] and Al-Jarallah et al. [11] and Furuta et al. [7], each concluding that thorium is subject to minimal evaporation during burning. Figure 4. Build-up daughter nuclides during and after burning mantle. 3.3. Thorium Concentration in Gas Mantle Thorium concentrations in mantles M1 and M5, analyzed by ICP-OES (Table 4), show values of 1.50 and 507.9 mg/g, respectively. The mantle M5 thorium content of 50% compares with the Furuta et al. [7] review of between 3.1 to 18% and Aksoy et al. [12] of 3.6 to 18.2%. The total absolute thorium content (activity) of the two samples M1 and M5 were 4.05 mg (16.5 Bq) and 1773 mg (7198 Bq), respectively. It is observed that the results for sample M1 and M5 in Tables 1 and 4 are comparable, however the activity for sample M5 (Table 1) recorded values greater than the result in Table 4, due to the high concentration of thorium in mantles M5. Table 4. ICP-OES analysis for thorium content in the mantle. Sample Candle Power (C.P.) Element (mg/g) (mg/Mantle) M1 (500–600 C.P.) Th 1.50 4.05 1 M5 (300–400 C.P.) 507.9 1773 2 1 Weight of the mantle M1 (2.7 g), 2 Weight of the mantle M5 (3.49 g). According to the Indian Atomic Energy Regulatory Board AERB-SS-4 consumer products guidelines, the exemption limit for the content of thorium is 600 mg for candle Figure 4. Build-up daughter nuclides during and after burning mantle. 3.3. Thorium Concentration in Gas Mantle Thorium concentrations in mantles M1 and M5, analyzed by ICP-OES (Table 4), show values of 1.50 and 507.9 mg/g, respectively. The mantle M5 thorium content of 50% compares with the Furuta et al. [ 7 ] review of between 3.1 to 18% and Aksoy et al. [ 12 ] of 3.6 to 18.2%. The total absolute thorium content (activity) of the two samples M1 and M5 were 4.05 mg (16.5 Bq) and 1773 mg (7198 Bq), respectively. It is observed that the results for sample M1 and M5 in Tables 1and 4are comparable, however the activity for sample M5 (Table 1) recorded values greater than the result in Table 4, due to the high concentration of thorium in mantles M5. Table 4. ICP-OES analysis for thorium content in the mantle. Sample Candle Power (C.P.) Element (mg/g) (mg/Mantle) M1 (500–600 C.P.) Th 1.50 4.05 1 M5 (300–400 C.P.) 507.9 1773 2 1Weight of the mantle M1 (2.7 g), 2Weight of the mantle M5 (3.49 g). According to the Indian Atomic Energy Regulatory Board AERB-SS-4 consumer products guidelines, the exemption limit for the content of thorium is 600 mg for candle power up to 400 CP/mantle [ 20 ], candle power (CP) representing measurement of luminous intensity. By that measure, the M5 thorium content of the present work is 1773 mg/mantle, a value exceeding the Indian exemption limit. In regard to a test of manufacturing quality, as required in Indian regulations, mantle M1 recorded 8 Bq while mantle M5 recorded 2445 Bq, the latter exceeding the Indian consumer products AERB-SS-4 guidelines, the value for manufacture quality in terms of radioactivity release being limited to no more than 185 Bq. Unlike the AERB-SS-4 provisions in India, in Malaysia no such control is found. More specifically, for present interests in particular, no control measures are found that pertain to the amount of impregnated thorium in a mantle. Moreover, the ability for public purchase conflicts with the ALARA “as low as reasonably achievable” principle, radioactive and non-radioactive mantles being found to be equally bright [ 7 ]. The ALARA principle, in the context of the present situation, implies a need for control in the use of the sale and use of such a consumer product. 3.4. Organ Equivalent and Effective Doses Organ equivalent doses were based on MIRD5 mathematical male and female phantoms, with the mantle simulated at 20 cm from the chest. Figure 5shows the equivalent
Appl. Sci. 2021,11, 1311 8 of 11 doses for the 21 predominant organs, the thymus, heart, and lung being the most greatly exposed organs due to their close proximity to the source. Appl. Sci. 2021, 11, x FOR PEER REVIEW 8 of 11 power up to 400 CP/mantle [20], candle power (CP) representing measurement of luminous intensity. By that measure, the M5 thorium content of the present work is 1773 mg/mantle, a value exceeding the Indian exemption limit. In regard to a test of manufacturing quality, as required in Indian regulations, mantle M1 recorded 8 Bq while mantle M5 recorded 2445 Bq, the latter exceeding the Indian consumer products AERB-SS-4 guidelines, the value for manufacture quality in terms of radioactivity release being limited to no more than 185 Bq. Unlike the AERB-SS-4 provisions in India, in Malaysia no such control is found. More specifically, for present interests in particular, no control measures are found that pertain to the amount of impregnated thorium in a mantle. Moreover, the ability for public purchase conflicts with the ALARA “as low as reasonably achievable” principle, radioactive and non-radioactive mantles being found to be equally bright [7]. The ALARA principle, in the context of the present situation, implies a need for control in the use of the sale and use of such a consumer product. 3.4. Organ Equivalent and Effective Doses Organ equivalent doses were based on MIRD5 mathematical male and female phantoms, with the mantle simulated at 20 cm from the chest. Figure 5 shows the equivalent doses for the 21 predominant organs, the thymus, heart, and lung being the most greatly exposed organs due to their close proximity to the source. Figure 5. Organ equivalent dose (µSv/h) for the 21 organs of the MIRD5 mathematical male and female phantom with mantle M5 simulated 20 cm from the chest. The greatest equivalent dose resulting from proximity to a single M5 mantle was indicated to be to the thymus, at 0.68 and 0.62 µSv/h for the male and female phantom respectively. Further, the equivalent dose to the stomach is also seen to be greater than that for most other organs due to the larger exposure area. Further investigation has been of the effective dose, as shown in Table 5. Figure 5. Organ equivalent dose ( µ Sv/h) for the 21 organs of the MIRD5 mathematical male and female phantom with mantle M5 simulated 20 cm from the chest. The greatest equivalent dose resulting from proximity to a single M5 mantle was indicated to be to the thymus, at 0.68 and 0.62 µ Sv/h for the male and female phantom respectively. Further, the equivalent dose to the stomach is also seen to be greater than that for most other organs due to the larger exposure area. Further investigation has been of the effective dose, as shown in Table 5. Table 5. Effective dose (µSv/h) from mantles at separations from the chest of 10, 20, 50 and 100 cm. Sample 10 cm 20 cm 50 cm 100 cm M1 4.96 ×10−44.67 ×10−41.81 ×10−43.18 ×10−7 M2 3.87 ×10−43.77 ×10−41.93 ×10−42.27 ×10−7 M3 2.54 ×10−42.00 ×10−47.60 ×10−51.14 ×10−7 M4 2.46 ×10−31.87 ×10−38.90 ×10−48.00 ×10−7 M5 3.41 ×10−12.95 ×10−11.45 ×10−12.94 ×10−4 With regard to evaluation of the effective dose, the dose conversion factors (DCFs) have been calculated by MC simulation. Table 5shows the results from a single mantle at separations from the chest of 10, 20, 50, and 100 cm; the effective doses for samples from M1 to M4 are very low to negligible compared to sample M5. It was observed that sample M5 recorded the maximum effective dose, at 3.41 × 10 −1 at a distance 10 cm, reducing to 2.94 ×10−4at 100 cm. The dose equivalent was also measured for mantle M5, using a calibrated IdentiFinder 2, FLIR Survey Meter, for exposure periods of 1, 4, 168, and 720 h, the meter being placed at distances of 0, 10, 20, 50, and 100 cm from the mantle. For a single M5 mantle, the contact
Appl. Sci. 2021,11, 1311 9 of 11 dose equivalent was 490 µ Sv per 720 h (30 days), reducing to 144 µ Sv at 20 cm (Table 6). For a package of six mantles placed on the surface of the survey meter, a dose equivalent of 1.368 mSv per 720 h was found, reducing to 0.187 mSv at 20 cm. The dose equivalent on the surface of a single mantle M5 was 0.68 µ Sv/h and on the surface of the package of six mantles, it was 1.9 µ Sv/h. It was observed that our results in Tables 5and 6for single mantle M5 are comparable. Table 6. Dose equivalent ( µ Sv per time exposure) measured with a survey meter (IdentiFinder 2) for mantle M5. Time Exposure Source Distance (cm) from Survey Meter Surface 10 20 50 100 1 mantle 1 h 0.68 0.25 0.2 0.17 BL * 4 h 2.72 1 0.8 0.68 BL 168 h 114.2 42 33.6 28.6 BL 720 h 490 180 144 122.4 BL 1 pack 1 h 1.9 0.35 0.234 0.19 BL 4 h 7.6 1.4 0.936 0.76 BL 168 h 319.2 58.8 39.3 31.9 BL 720 h 1368 189 187.2 136.8 BL BL.*: Background Level (0.1 µSv/h). In Malaysia, gas lantern mantles are commercially available without restrictions and have been widely used in lighting in rural areas where electricity supply is limited, also for illumination of night food stalls as well as for fishing and camping activities. In the example case of night markets in Malaysia, open from 6:00 p.m. to 10:00 p.m., also with the assumption that a double mantle gas lantern lamp is used for four hours per night, the annual dose can reach 0.6 mSv per year, assuming a dose equivalent at 20 cm of 0.2 µ Sv/h see (Table 6). This is greatly in excess of the dose constraint of 0.3 mSv/y from any single source [ 26 ]. In yet another example, concerning warehouse storage and courier services, workers may receive unnecessary exposures of up to 1.9 µ Sv/h on the surface of packages of six mantles, referring again to (Table 6). Assuming a worker spends two hours per day handling such packages, the annual dose may exceed the permissible limit of 1 mSv/y for members of the public [ 27 – 29 ]. The standard specifications for consumer products certainly need to be revised for inspection by the regulatory bodies to ensure compliance by lantern mantle manufacturers in order to meet the requirement of keeping the radiation dose to individual members of the public as low as reasonably achievable. It is suggested that such harmonization of practice will provide an important step towards the design and production of safer consumer products for public use. 4. Conclusions Five different types of mantle were investigated in this study. The content of thorium in mantle M5 was found to be 50%, a value exceeding the highest levels reported in the existing literature. Mantle M5 recorded the highest thorium activity at 1.25 × 10 4 Bq, exceeding the exemption limit for thorium of 1 × 10 4 Bq adopted by the IAEA (2014). Further estimate has shown the dose equivalent on the surface of a single M5 mantle to be 0.68 µ Sv/h, while on the surface of a package of six mantles it can increase to 1.9 µ Sv/h. Two scenarios have been described, both showing that close contact with a package of M5 mantles can infer annual doses in excess of the dose constraint of 0.3 mSv/y from a single source, the second example inferring levels exceeding the permissible limit of 1 mSv/y for members of the public. Currently radioactive mantles are available for purchase without information concerning their radioactivity. Additionally, there is no impediment to the purchase of these in Malaysia, the country of present study. There is need to set criteria for the approving of thorium based lantern mantle products before their release for purchase and use by members of the public.