materials Article Complex Corrosion Properties of AISI 316L Steel Prepared by 3D Printing Technology for Possible Implant Applications Josef Hlinka 1,* , Martin Kraus 1, Jiri Hajnys 2, Marek Pagac 2, Jana Petr˚u 2, Zbigniew Brytan 3and Tomasz Ta´nski 3 1Department of Materials Engineering, Faculty of Materials and Technology, VSB-Technical University of Ostrava, 17. listopadu 2172/15, 708 00 Ostrava-Poruba, Czech Republic; [email protected] 2Department of Machining, Assembly and Engineering Metrology, Faculty of Mechanical Engineering, Technical University of Ostrava, 17. listopadu 2172/15, 708 00 Ostrava-Poruba, Czech Republic; [email protected] (J.H.); [email protected] (M.P.); [email protected] (J.P.) 3Department of Engineering Materials and Biomaterials, Faculty of Mechanical Engineering, Silesian University of Technology, Konarskiego 18a, 44-100 Gliwice, Poland; zbigniew[email protected] (Z.B.); T[email protected] (T.T.) *Correspondence: [email protected]; Tel.: +4206-0851-1090 Received: 29 February 2020; Accepted: 24 March 2020; Published: 26 March 2020 Abstract: This paper deals with the investigation of complex corrosion properties of 3D printed AISI 316L steel and the influence of additional heat treatment on the resulting corrosion and mechanical parameters. There was an isotonic solution used for the simulation of the human body and a diluted sulfuric acid solution for the study of intergranular corrosion damage of the tested samples. There were significant microstructural changes found for each type of heat treatment at 650 and 1050 ◦ C, which resulted in different corrosion properties of the tested samples. There were changes of corrosion potential, corrosion rate and polarization resistance found by the potentiodynamic polarization method. With regard to these results, the most appropriate heat treatment can be applied to applications with intended use in medicine. Keywords: additive manufacturing; implants; corrosion; wettability; biocompatibility; polarization; heat treatment 1. Introduction Additive manufacturing technology is a modern metallurgical method based on the principle of gradual sintering of the powder material layer by layer until the finished product is reached. With the help of selective laser melting (SLM) technology, it is possible to quickly produce fully functional and complexly-shaped parts, which are often not produced by other conventional technologies [ 1 ]. Due to the continuous development of this technology, a low porosity has been achieved, which is associated with a significant increase in the quality of manufactured parts. Nowadays, 3D printing products are broadly used in a wide range of applications, from the automotive, aerospace and aerospace industries, with a variety of tool inserts, landing gears and turbines [ 2 ]—to the medical industry where they are most often used as hard tissue replacements [ 3 ]. Nevertheless, SLM relates to high temperature gradients, which have a major influence on the resulting microstructural and mechanical properties of manufactured parts [ 4 ]. The proper choice of process parameters therefore directly affects metallurgical processes with an impact on porosity, surface character and residual stresses in the volume of the material [ 5 ]. The last of those mentioned may be eliminated by the application of heat treatment, which results in microstructural changes and can also cause the sensitization of grain Materials 2020,13, 1527; doi:10.3390/ma13071527 www.mdpi.com/journal/materials
Materials 2020,13, 1527 2 of 21 boundaries or can have a significant effect on corrosion parameters, which are primarily important for the use of material within implant construction. According to ASTM standards, the material used for implant manufacturing must meet corrosion properties requirements, or else it cannot be used for this purpose [6]. Stainless steels have been commonly used in implantology for decades, especially for their corrosion resistance which is associated with self-passivation due to spontaneously-formed chromium oxides on the surface [ 7 , 8 ]. Corrosion characteristics of stainless steel implant surfaces can also be enhanced by chemical passivation [ 9 ], electrochemical passivation [ 10 ] or active coatings [ 11 ]. As with other materials with self-passivation ability, stainless steels are sensitive to localized forms of corrosion, especially in an environment containing highly reactive halide ions; i.e., F − or Cl − [ 12 ]. Pitting corrosion often occurs as a result of corrosion microcouple formation around a secondary phase particle with more noble electrochemical potential. This causes selective corrosion of a less stable surrounding metallic matrix [ 13 ]. In the case of additively manufactured stainless steel, these particles of secondary phases may originate in the impurities of powders used [ 14 ], the reaction of melted material with the atmosphere [ 15 ] or may be formed during inappropriate heat treatment [ 16 ]. As the powder’s impurities and content, and the inert atmosphere quality are process characteristics which can be easily adjusted, the effect of heat treatment on the corrosion properties of additively manufactured material plays a key role in the development process of innovative applications, from austenitic stainless steels for use in medicine to implantology. The main motivation of presented study is to compare selected properties of AISI 316L prepared by SLM and classical AISI 316L. 2. Material, Heat Treatment and Experimental Techniques 2.1. Material and Processing Parameters Investigations were performed on the austenitic stainless steel AISI 316L prepared by the additive manufacturing process from atomized powder certified by Renishaw with an average particle size of 45 ± 15 µ m. The chemical composition according to the Renishaw certificate is listed in the following Table 1. Table 1. Chemical composition of atomized AISI 316L powder according to Renishaw certification. Chemical Composition (wt. %) C Si Mn P S N Cr Mo Ni Fe Max. Max. Max. Max. Max. Max. Min.–Max. Min.–Max. Min.–Max. Balance 0.03 1.00 2.00 0.045 0.03 0.10 16.00–18.00 2.00–3.00 10.00–14.00 The Renishaw AM400 device in selective laser melting mode was used for sample production. The setup parameters used for manufacturing are presented in Table 2. Table 2. Parameters of SLM process. Manufacturing Parameter Value Laser power (W) 200 Speed scanning (mm/s) 650 Exposure time (µs) 80 Laser beam diameter (µm) 80 Powder layer thickness (µm) 50 Hatching pattern Chessboard After the LSM process, the samples in the shape of a longitudinally cut letter “H” were separated from the supporting plate and cleansed of powder residues using an ultrasonic bath with demineralized
Materials 2020,13, 1527 3 of 21 water and acetone for 5 minutes each. After that, the middle sections of the samples were mechanically cut offby a diamond rotary blade with a water cooling system to prevent overheating and structural changes in the material. The sample shapes with marks for cutting are illustrated in Figure 1. overheating and structural changes in the material. The sample shapes with marks for cutting are illustrated in Figure 1. 2.2. Heat treatment The samples were further mechanically grinded using rotary sandpapers (grid 100–200–400– 800–1500). A Struers machine was used until all SLM surface relief marks disappeared, leaving the surface with shallow scratches. At this stage, samples were divided into two categories according to the planned heat treatment. The third category contained only reference samples where no heat treatment was applied (Table 3). Table 3. Parameters of heat treatment in vacuum chamber for each batch of samples. Heat Treatment Parameters HT1 HT2 REF (State after SLM) Temperature 650 °C 1050 °C - Holding time 30 min 30 min - Heating rate 20 °C.min-1 20 °C.min-1 - Cooling Slow-in chamber Slow-in chamber - The heat treatment parameters were selected intentionally according to [8,17–19] to simulate conditions of previously performed experiments with promising results for use in the biomechanical engineering industry. While the main reason for applying 650 °C/30 min of annealing was to reduce residual stress without significant microstructural changes, diffusion processes running during 1050 °C/30 min causes complete recrystallization with a reduction of texture and SLM artefacts in the microstructure As the cooling was very slow with a low temperature gradient, there was also no phase transformation resulting in mechanical stress accumulation expected. The standard annealing heat treatment of austenitic stainless steels applies a fast cooling rate after austenitization to prevent chromium carbide precipitation during cooling. In the present study, AISI 316L grade is not affected by any precipitation processes during the slow cooling rate applied due to low carbon content. Thus, the slow cooling can effectively eliminate residual stresses without introducing further ones during cooling. To avoid a chemical reaction between the free metallic surface and the atmosphere, the heat treatment was performed in a low pressure (1300 Pa) inert gas (argon) atmosphere. 2.3. Chemical Composition, Microstructure and Metallography Observation The purity of the manufacturing chamber atmosphere together with other parameters of the SLM process may cause minor changes to the final sample chemical composition, which may vary insignificantly from the powder used for its preparation. In particular, interstitial atoms (C,N,O) present in the air in the form of gases or organic pollutants may form secondary phases and negatively affect the surface and corrosion properties of the final material [20]. Therefore the chemical composition of the samples was verified by glow discharge optical emission spectrometry (GDOES) using a GDA 750 device from Spectruma (Hof, Germany). This method uses plasma generated by strong electric field for sputtering of the sample atoms, which are further analyzed and quantified. Figure 1. Samples for further testing Figure 1. Samples for further testing. 2.2. Heat Treatment The samples were further mechanically grinded using rotary sandpapers (grid 100–200–400–800–1500). A Struers machine was used until all SLM surface relief marks disappeared, leaving the surface with shallow scratches. At this stage, samples were divided into two categories according to the planned heat treatment. The third category contained only reference samples where no heat treatment was applied (Table 3). Table 3. Parameters of heat treatment in vacuum chamber for each batch of samples. Heat Treatment Parameters HT1 HT2 REF (State after SLM) Temperature 650 ◦C 1050 ◦C - Holding time 30 min 30 min - Heating rate 20 ◦C min−120 ◦C min−1Cooling Slow-in chamber Slow-in chamber - The heat treatment parameters were selected intentionally according to [ 8 , 17 – 19 ] to simulate conditions of previously performed experiments with promising results for use in the biomechanical engineering industry. While the main reason for applying 650 ◦ C/30 min of annealing was to reduce residual stress without significant microstructural changes, diffusion processes running during 1050 ◦ C/30 min causes complete recrystallization with a reduction of texture and SLM artefacts in the microstructure As the cooling was very slow with a low temperature gradient, there was also no phase transformation resulting in mechanical stress accumulation expected. The standard annealing heat treatment of austenitic stainless steels applies a fast cooling rate after austenitization to prevent chromium carbide precipitation during cooling. In the present study, AISI 316L grade is not affected by any precipitation processes during the slow cooling rate applied due to low carbon content. Thus, the slow cooling can effectively eliminate residual stresses without introducing further ones during cooling. To avoid a chemical reaction between the free metallic surface and the atmosphere, the heat treatment was performed in a low pressure (1300 Pa) inert gas (argon) atmosphere. 2.3. Chemical Composition, Microstructure and Metallography Observation The purity of the manufacturing chamber atmosphere together with other parameters of the SLM process may cause minor changes to the final sample chemical composition, which may vary insignificantly from the powder used for its preparation. In particular, interstitial atoms (C,N,O) present in the air in the form of gases or organic pollutants may form secondary phases and negatively affect the surface and corrosion properties of the final material [ 20 ]. Therefore the chemical composition of the samples was verified by glow discharge optical emission spectrometry (GDOES) using a GDA
Materials 2020,13, 1527 4 of 21 750 device from Spectruma (Hof, Germany). This method uses plasma generated by strong electric field for sputtering of the sample atoms, which are further analyzed and quantified. For the evaluation of the corrosive effect and the basic semi-quantitative chemical properties, an analysis of the surface layer was performed using an SEM FEI 450 Quanta FEG ( FEI Company, Brno, Czech Republic) equipped with an EDAX EDS detector (AMATEK Company, Tilburg, Netherlands) in the secondary electron mode. Accelerating the voltage to 15 keV allowed us to analyze a wide range of chemical elements from the periodic table. Due to the shape of the analyzed sample, the working distance was 11–12 mm. The metallography observations were performed on samples after mechanical polishing using equipment and diamond suspensions made by Struers (Roztoky, Czech Republic) with chemical etching (22 ◦ C/60s) in a modified Vilella’s reagent [ 21 ] containing 10 parts 35%HCl, 10 parts distilled H 2 O and 1 part 65% HNO 3 . The image capturing and evaluation was performed by an Olympus IX70 inverted metallographic microscope (Olympus, Praque, Czech Republic) 2.4. Corrosion Testing Methods AISI 316L is a material with a very low corrosion rate under normal conditions. It follows from the aforementioned material characteristics that accelerated testing methods had to be used; otherwise the standard material immersion tests could take decades. Corrosion tests were performed on a Voltalab PGZ 100 with Voltamaster 10 software (Villeurbanne, France). The test methods were selected and performed according to ASTM F 2129, ASTM G 61 and ISO 12732 with certain temperature and gas bubbling modifications in regard to subsequent application in biomedical engineering. All corrosion tests were performed in customized HDPP/HDPE corrosion cells with a lower hole exposing 0.5 cm 2 of the tested surface. This setup allows bubbles formed on the surface during tests to escape and not to affect continuity of the measurements. A three-electrode setup, composed of a sample connected as a working electrode and a saturated calomel electrode (SCE, +241 mV vs. Saturated Hydrogen Electrode (SHE)) [ 22 ], was set as a reference electrode, and a high purity carbon rod was connected as an auxiliary electrode. The physiological saline solution (0.9 wt. % NaCl in distilled H 2 O) was used as a corrosion solution for potentiodynamic polarization, as well as open circuit potential (OCP) tests to intentionally simulate the environment of living tissue. The temperature of all tests was 25 ◦ C. OCP measurements were performed by comparing a potential set on the working electrode and reference electrode. Therefore, all potentials in this paper are against SCE [23]. Before starting the potentiodynamic polarization, the initial potential value was set to − 100 mV vs. the potential after stabilization of the corrosion equilibrium (OCP), with the polarization rate set to 60 mV.min −1 [ 24 ]. The dependence of the current flowing through the potential applied to the test sample was recorded during the measurement. The potential was gradually applied to the measured sample, which increased over time with the value of the polarization rate. After a surge in the current passing through the sample, the passive layer breakdown value was recorded, and reverse polarization was started after reaching the critical current density limit (5 × 10 −3 A cm −2 ) In reverse polarization, the voltage was gradually decreased with the value of the polarization rate and the current passing through the sample was recorded again. If the reverse polarization current reached negative values or the potential was below the initial test value, the test was terminated. The changes in electrochemical behavior due to heat treatment were studied using the double loop electrochemical potentiokinetic reactivation (DL-EPR) method. The electrolyte prepared for this test contained 2 M H 2 SO 4 and 0.02 M KSCN in distilled water. The tests were carried out at room temperature (25 ◦C). 2.5. Wettability and Surface Energy The wettability of the sample was evaluated by the sessile drop method. The surface contact angle was found by the SEE system and free surface energy was calculated by Advex Instrument software. There were 2 µ L droplets of double distilled water attached to the tested surface and the contact angle θ was determined by the tangent to the drop profile at the point of contact of the three phases (liquid, solid, gas) with the plane of the sample surface [ 25 ]. The free surface energy of the solid sample is
Materials 2020,13, 1527 5 of 21 determined Young’s Equation (1), where γS , γSL , and γL represent the interfacial tensions per unit length of the solid-vapor, solid-liquid, and liquid-vapor contact line respectively [26]. γsv −γsl =γlv cos θ(1) 3. Results 3.1. Porosity The thresholding method was used to determine porosity. Images were transformed into B/W and total percentage of black dots representing pores was calculated [ 27 ]. This method is similar to ASTM E1245. Low magnification was used to eliminate the risk of variating the pores’ concentration effects in different sample parts. Three images of polished cross-sections cuts without etching were taken for each sample at 20 × magnification. The representative images of samples from each batch are shown in Figure 2. The average porosity values calculated from and are listed in Table 4. tensions per unit length of the solid-vapor, solid-liquid, and liquid-vapor contact line respectively [26]. 𝜸𝒔𝒗 −𝜸 𝒔𝒍 =𝜸 𝒍𝒗 𝒄𝒐𝒔 𝜽 (1) 3. Results 3.1. Porosity The thresholding method was used to determine porosity. Images were transformed into B/W and total percentage of black dots representing pores was calculated [27]. This method is similar to ASTM E1245. Low magnification was used to eliminate the risk of variating the pores’ concentration effects in different sample parts. Three images of polished cross-sections cuts without etching were taken for each sample at 20× magnification. The representative images of samples from each batch are shown in Figure 2. The average porosity values calculated from and are listed in Table 4. Figure 2. Macroimage of surfaces of HT1, HT2 and REF samples used for porosity determination. Table 4. Average porosity values for each sample. Sample Average porosity (%) HT1 0.03 HT2 0.07 REF 0.08 Figure 2. Macroimage of surfaces of HT1, HT2 and REF samples used for porosity determination. Table 4. Average porosity values for each sample. Sample Average Porosity (%) HT1 0.03 HT2 0.07 REF 0.08 All samples show a similar level of porosity. It is an undeniable fact that porosity is created exclusively during the stage of the material production process and no pores are formed during subsequent stages of heat treatment [ 28 ]. The character of the pores is analogical for all samples—there are non-melted surface powder particles visible on the sides and very bottom of the pores which indicates insufficient melting during laser beam movement. This is illustrated in Figure 3. There are also microcracks visible in the sharp edges of the pores—these may act as stress concentration zones
Materials 2020,13, 1527 6 of 21 and initiate the formation of fatigue cracks [ 29 ]. Only a very small number of pores exhibit smooth edges, and these are connected to gas being trapped in microstructure during the melting process, producing gas pockets [30]. All samples show a similar level of porosity. It is an undeniable fact that porosity is created exclusively during the stage of the material production process and no pores are formed during subsequent stages of heat treatment [28]. The character of the pores is analogical for all samples— there are non-melted surface powder particles visible on the sides and very bottom of the pores which indicates insufficient melting during laser beam movement. This is illustrated in Figure 3. There are also microcracks visible in the sharp edges of the pores—these may act as stress concentration zones and initiate the formation of fatigue cracks [29]. Only a very small number of pores exhibit smooth edges, and these are connected to gas being trapped in microstructure during the melting process, producing gas pockets [30]. 3.2. Chemical Composition Chemical composition was repeatedly measured on the sample surfaces using the GDOES method five times in different areas to eliminate the influence of local chemical composition deviations. The results were averaged and are presented in Table 5. According to the tests, the material of the samples fully corresponds with Renishaw certification and ASTM A276-98 standard. Table 5. Averaged chemical composition obtained by GDOES method. Chemical Composition-Content of Each Element in Tested Material AISI 316L (wt.%) C (%) Mn (%) Si (%) P (%) S (%) Cr (%) Ni (%) Mo (%) Cu (%) <0,001 1.70 0.22 0.023 0.001 17.72 14.24 2.73 0.077 Co (%) B (%) Pb (%) V (%) W (%) Al (%) Nb (%) Ti (%) Fe (%) 0.048 0.0022 <0,001 <0,001 0.19 0.010 0.013 0.003 Balance 3.3. Microstructure Figures 4–6 show images of the sample structure of HT1, HT2 and REF at 100× magnification. The images were taken in the direction of the application of individual layers of additive production and in the direction perpendicular to the direction of the application of layers (cross-section of the samples). There are melt pools clearly visible in the cross-section of the HT1 and REF samples where equiaxial austenitic grains are formed randomly in the microstructure and lie within the melt pools and across the melt pool boundaries [31]. Figure 3. Microstructure of pores in detail, showing nonmelted round particles inside. Figure 3. Microstructure of pores in detail, showing nonmelted round particles inside. 3.2. Chemical Composition Chemical composition was repeatedly measured on the sample surfaces using the GDOES method five times in different areas to eliminate the influence of local chemical composition deviations. The results were averaged and are presented in Table 5. According to the tests, the material of the samples fully corresponds with Renishaw certification and ASTM A276-98 standard. Table 5. Averaged chemical composition obtained by GDOES method. Chemical Composition-Content of Each Element in Tested Material AISI 316L (wt.%) C (%) Mn (%) Si (%) P (%) S (%) Cr (%) Ni (%) Mo (%) Cu (%) <0.001 1.70 0.22 0.023 0.001 17.72 14.24 2.73 0.077 Co (%) B (%) Pb (%) V (%) W (%) Al (%) Nb (%) Ti (%) Fe (%) 0.048 0.0022 <0.001 <0.001 0.19 0.010 0.013 0.003 Balance 3.3. Microstructure Figures 4–6show images of the sample structure of HT1, HT2 and REF at 100 × magnification. The images were taken in the direction of the application of individual layers of additive production and in the direction perpendicular to the direction of the application of layers (cross-section of the samples). There are melt pools clearly visible in the cross-section of the HT1 and REF samples where equiaxial austenitic grains are formed randomly in the microstructure and lie within the melt pools and across the melt pool boundaries [31].
Materials 2020,13, 1527 7 of 21 Figure 4. Microstructure of sample HT1: (A) in direction parallel with direction of application of individual layers, (B) in direction perpendicular to direction of application of individual layers (etched in Villella). Figure 5. Microstructure of sample HT2: (A) in direction parallel with direction of application of individual layers, (B) in direction perpendicular to direction of application of individual layers (etched in Villella). Figure 6. Microstructure of sample REF: (A) in direction parallel with direction of application of individual layers, (B) in direction perpendicular to direction of application of individual layers (etched in Villella). In the longitudinal direction (direction of the application of individual layers), the relief of the individual melt pools welded together is clearly visible on the metallographic samples of HT1 and REF. The randomly formed austenitic grains lie again either within individual melt pools or across Figure 4. Microstructure of sample HT1: ( A ) in direction parallel with direction of application of individual layers, ( B ) in direction perpendicular to direction of application of individual layers (etched in Villella). Figure 4. Microstructure of sample HT1: (A) in direction parallel with direction of application of individual layers, (B) in direction perpendicular to direction of application of individual layers (etched in Villella). Figure 5. Microstructure of sample HT2: (A) in direction parallel with direction of application of individual layers, (B) in direction perpendicular to direction of application of individual layers (etched in Villella). Figure 6. Microstructure of sample REF: (A) in direction parallel with direction of application of individual layers, (B) in direction perpendicular to direction of application of individual layers (etched in Villella). In the longitudinal direction (direction of the application of individual layers), the relief of the individual melt pools welded together is clearly visible on the metallographic samples of HT1 and REF. The randomly formed austenitic grains lie again either within individual melt pools or across Figure 5. Microstructure of sample HT2: ( A ) in direction parallel with direction of application of individual layers, ( B ) in direction perpendicular to direction of application of individual layers (etched in Villella). Figure 4. Microstructure of sample HT1: (A) in direction parallel with direction of application of individual layers, (B) in direction perpendicular to direction of application of individual layers (etched in Villella). Figure 5. Microstructure of sample HT2: (A) in direction parallel with direction of application of individual layers, (B) in direction perpendicular to direction of application of individual layers (etched in Villella). Figure 6. Microstructure of sample REF: (A) in direction parallel with direction of application of individual layers, (B) in direction perpendicular to direction of application of individual layers (etched in Villella). In the longitudinal direction (direction of the application of individual layers), the relief of the individual melt pools welded together is clearly visible on the metallographic samples of HT1 and REF. The randomly formed austenitic grains lie again either within individual melt pools or across Figure 6. Microstructure of sample REF: ( A ) in direction parallel with direction of application of individual layers, ( B ) in direction perpendicular to direction of application of individual layers (etched in Villella). In the longitudinal direction (direction of the application of individual layers), the relief of the individual melt pools welded together is clearly visible on the metallographic samples of HT1 and
Materials 2020,13, 1527 8 of 21 REF. The randomly formed austenitic grains lie again either within individual melt pools or across melt pool boundaries. This effect is caused by epitaxy in combination with preferable heterogeneous solidification of liquid metal on the solid edges of the melt pools where the atoms of solidifying metal take over the orientation of surrounding grains and grow preferably in line with a negative temperature gradient. No characteristics of 3D printing are visible on the HT2 sample. The structure consists of equiaxial austenitic grains. The loss of the characteristic structure is caused by a heat treatment at 1050 ◦ C. At this temperature, a total recrystallization of the microstructure occurred. There are no signs of melt pools visible, either in a perpendicular direction or in a parallel one, with regard to layer application. The HT2 sample shows a significantly larger grain size than HT1 and REF. This is caused by coarsening accelerated by high temperature exposure [32]. 3.4. Open Circuit Potential and Cyclic Polarization Open circuit potential measurement vs. SCE mV was first performed after 1 hour from filling the corrosion cells with a physiological solution—this time gap was to allow electrochemical processes to establish an equilibrium between oxidation and reduction based sub reactions [ 33 ]. Following OCP, measurements were performed with 24-hour periodicity. During this period, approximately one half of the corrosion solution volume was replaced by fresh solution after each measurement to avoid the risk of bacterial colonies forming in the solution and on the corrosion cell walls, which could affect solution characteristics and the results themselves, respectively. After 169 h (seven days), the last values of OCP were measured. The results of the measurements are shown in Table 6and then graphically depicted in the chart in Figure 7, where the individual points are fitted with a suitable trend of second grade polynomic curve and the evolution of OCP in time can be evaluated for each sample Table 6. Open circuit potential values evolution in 169 hours of exposition. Sample Open Circuit Potential vs. SCE (mV) 1 h 25 h 49 h 73 h 97 h 121 h 145 h 169 h HT1 −135 −130 −61 −49 −22 28 61 50 HT2 −165 −86 −45 3 11 29 43 86 REF −129 −90 −120 −45 −28 −19 −25 −10 melt pool boundaries. This effect is caused by epitaxy in combination with preferable heterogeneous solidification of liquid metal on the solid edges of the melt pools where the atoms of solidifying metal take over the orientation of surrounding grains and grow preferably in line with a negative temperature gradient. No characteristics of 3D printing are visible on the HT2 sample. The structure consists of equiaxial austenitic grains. The loss of the characteristic structure is caused by a heat treatment at 1050 °C. At this temperature, a total recrystallization of the microstructure occurred. There are no signs of melt pools visible, either in a perpendicular direction or in a parallel one, with regard to layer application. The HT2 sample shows a significantly larger grain size than HT1 and REF. This is caused by coarsening accelerated by high temperature exposure [32]. 3.4. Open Circuit Potential and Cyclic Polarization Open circuit potential measurement vs. SCE mV was first performed after 1 hour from filling the corrosion cells with a physiological solution—this time gap was to allow electrochemical processes to establish an equilibrium between oxidation and reduction based sub reactions [33]. Following OCP, measurements were performed with 24-hour periodicity. During this period, approximately one half of the corrosion solution volume was replaced by fresh solution after each measurement to avoid the risk of bacterial colonies forming in the solution and on the corrosion cell walls, which could affect solution characteristics and the results themselves, respectively. After 169 h (seven days), the last values of OCP were measured. The results of the measurements are shown in Table 6 and then graphically depicted in the chart in Figure 7, where the individual points are fitted with a suitable trend of second grade polynomic curve and the evolution of OCP in time can be evaluated for each sample Table 6. Open circuit potential values evolution in 169 hours of exposition. Sample Open Circuit Potential vs. SCE (mV) 1 h 25 h 49 h 73 h 97 h 121 h 145 h 169 h HT1 −135 −130 −61 −49 −22 28 61 50 HT2 −165 −86 −45 3 11 29 43 86 REF −129 −90 −120 −45 −28 −19 −25 −10 -160 -110 -60 -10 40 90 0 24 48 72 96 120 144 168 Open circuit potential (mV vs. SCE) Time of exposition (hours) HT1 HT2 REF Figure 7 Chart of OCP evolution in 169 hours exposition for each sample Figure 7. Chart of OCP evolution in 169 hours exposition for each sample. From the very negative values of OCP measured after 1 h of sample exposition, it can be concluded that the surfaces of all samples were actively oxidized and only thin, spontaneously-formed oxide layers were covering the exposed surface [ 34 ]. With an increase of exposition time, the OCP potentials
Materials 2020,13, 1527 9 of 21 of all samples shifted to more positive values; this is related to the formation of a more electrochemically stable corrosion product on the exposed surfaces, probably in the form of hydrated oxides [ 35 ] and hydroxides [ 36 ]. The equilibria of the reactions occurring on exposed surfaces are then shifted to the side of the reduction processes which results in more noble potentials measured after more extended times of exposition of all samples. At the end of the testing procedure, i.e., after 169 hours, potentials of all samples were significantly elevated and became more noble, with the deviations of OCP between starting and final measured values being more significant for heat treated samples. In contrast, however, the reference sample showed a more respectable OCP evolution in time. After OCP testing procedure was finalized for all samples, the potentiodynamic polarization test was started. Since the previous procedure was completely non-invasive, there is no risk of results being affected by previous testing. The changes of OCP were determinated by electrochemical processes occurring naturally on the tested surface, not by the testing method itself. On the other hand, the potentiodynamic polarization test is a very invasive procedure in which the surface is actively corroded due to nature of polarization procedure. Therefore, the test cannot be performed twice in the same area [ 9 ]. When potentiodynamic polarization tests of all samples after 169 hours of exposure were finished, the samples were removed from the corrosion cell, and then re-mounted and slightly shifted from previous positions. Hence, the area for new tests was unaffected and completely intact. The corrosion cell was again filled with fresh corrosion solution and a one-hour delay was applied before performing the next potentiodynamic tests. In the end, there were two polarization curves for each sample measured (after 1 and 169 hours of exposition), which can be used to determine corrosion behavior evolution in time. The corrosion curves measured for each sample are shown in Figures 8–10; the different corrosion behaviors for samples HT1, HT2 and REF after 1 h and 169 h exposition are illustrated respectively. The polarization direction is indicated by black arrows in the plots. There were corrosion potentials found, in addition to polarization resistance and a corrosion rate calculated from the initial part of the polarization curves with the characteristic “V-shape” by Tafel extrapolation [ 37 ]. There was an exchange of two electrons (Fe 0→ Fe 2+ ), and an average material molar mass of 56.2 g/mol [ 38 ] was considered by calculating the corrosion rate. For the control, the Stern–Geary relation was used for determination of corrosion potential and polarization resistance [ 39 ]. These calculations were done automatically by Voltamaster 10 software and the results are listed in Table 7. The results of both methods should be comparable. From the very negative values of OCP measured after 1 h of sample exposition, it can be concluded that the surfaces of all samples were actively oxidized and only thin, spontaneouslyformed oxide layers were covering the exposed surface [34]. With an increase of exposition time, the OCP potentials of all samples shifted to more positive values; this is related to the formation of a more electrochemically stable corrosion product on the exposed surfaces, probably in the form of hydrated oxides [35] and hydroxides [36]. The equilibria of the reactions occurring on exposed surfaces are then shifted to the side of the reduction processes which results in more noble potentials measured after more extended times of exposition of all samples. At the end of the testing procedure, i.e., after 169 hours, potentials of all samples were significantly elevated and became more noble, with the deviations of OCP between starting and final measured values being more significant for heat treated samples. In contrast, however, the reference sample showed a more respectable OCP evolution in time. After OCP testing procedure was finalized for all samples, the potentiodynamic polarization test was started. Since the previous procedure was completely non-invasive, there is no risk of results being affected by previous testing. The changes of OCP were determinated by electrochemical processes occurring naturally on the tested surface, not by the testing method itself. On the other hand, the potentiodynamic polarization test is a very invasive procedure in which the surface is actively corroded due to nature of polarization procedure. Therefore, the test cannot be performed twice in the same area [9]. When potentiodynamic polarization tests of all samples after 169 hours of exposure were finished, the samples were removed from the corrosion cell, and then remounted and slightly shifted from previous positions. Hence, the area for new tests was unaffected and completely intact. The corrosion cell was again filled with fresh corrosion solution and a onehour delay was applied before performing the next potentiodynamic tests. In the end, there were two polarization curves for each sample measured (after 1 and 169 hours of exposition), which can be used to determine corrosion behavior evolution in time. The corrosion curves measured for each sample are shown in Figures 8, 9 and 10; the different corrosion behaviors for samples HT1, HT2 and REF after 1 h and 169 h exposition are illustrated respectively. The polarization direction is indicated by black arrows in the plots. There were corrosion potentials found, in addition to polarization resistance and a corrosion rate calculated from the initial part of the polarization curves with the characteristic “V-shape” by Tafel extrapolation [37]. There was an exchange of two electrons (Fe0→Fe2+), and an average material molar mass of 56.2 g/mol [38] was considered by calculating the corrosion rate. For the control, the Stern–Geary relation was used for determination of corrosion potential and polarization resistance [39]. These calculations were done automatically by Voltamaster 10 software and the results are listed in Table 7. The results of both methods should be comparable. 1.E-9 1.E-8 1.E-7 1.E-6 1.E-5 1.E-4 1.E-3 1.E-2 -0.3 0.2 0.7 1.2 1.7 Curent density log (A/cm2) Polarization potential (V vs. SCE) HT1_1h HT1_169h Figure 8. Semilogarithmic polarization curves for sample HT1 after 1 and 169 h of exposition in physiological solution . Figure 8. Semilogarithmic polarization curves for sample HT1 after 1 and 169 h of exposition in physiological solution.
Materials 2020,13, 1527 16 of 21 to corrode rapidly when breakdown potential is reached. On the other hand, fast solidification of REF sample microstructure did not allow substitute elements’ diffusion and precipitation in the form of secondary phase particles. This resulted in constant dissolving of less stable regions without the formation of galvanic microcouples. This effect was previously observed for additive manufacturing processes [73]. The results of EPR-DL showed that ASIS 316L manufactured by SLM indicates minor signs of grain boundary sensitization, and it was confirmed that both heat treatment strategies used even improved intergranular corrosion resistance. Previous studies performed on continuously casted AISI 316L [ 74 , 75 ] revealed significant grain boundary sensitization after heat treatment at 650 ◦ C/H 2 O due to the precipitation of chromium-rich secondary phases along the grain boundaries (mainly the M 23 C 6 and σ -phase). The exact opposite effect was confirmed for additively manufactured material heat treated at the same temperature used for research in this paper. It could probably be caused by long holding times (30 min) and a very slow cooling rate, when chromium atoms could defund grain boundaries and equalize their deficiency [ 74 , 76 ]. This resulted in an increasing of chromium volume content along grain boundaries and their possibility of spontaneous repassivation, even under conditions of aggressive sulfuric acid solution used for testing [ 77 ]. The indisputable fact is that powders used for the SLM method contained considerably lower carbon content than material used for experiments presented in studies: [ 74 , 75 ], which resulted in a reduced amount of chromium-rich carbide precipitated along grain boundaries, causing a less significant change of chromium dissolved in solid solution. Surface wettability was tested by the sessile drop method, wherein the contact angle between the tested surface and a small extra pure water droplet was measured. The SLM sample with no heat treatment was used for testing and the results were compared to continuously casted AISI 316L after the same surface preparation. This test confirmed a reduction in the contact angle for the SLM sample, which was approximately two times lower than for “standard” material. Studies have shown that increasing the wetting angle of the surface in the range of 0 ◦ –106 ◦ reduces the adhesion of osteoblasts (bone cells) to the surface. Conversely, the strongest adhesion of fibroblasts (fibrous cells) to the surface was observed at a wetting angle of 60 ◦ –80 ◦ [ 78 ]. According to this study, it can be stated that SLM AISI 316L material would be more suitable for the construction of long term implants where strong bonding to hard tissues is required. On the other hand, “standard” AISI 316L may be used for the manufacturing of short term implants, as there is mostly only soft fibrillar tissue bonded to its surface [ 79 ]. Increased surface wettability is also connected to accelerated adhesion of blood proteins, which is linked with the initial stage of the tissue healing process [80]. 5. Conclusions This novel research concerns a multidisciplinary study of the corrosion properties of AISI 316L stainless steel prepared by the selective laser melting method and the effects of two different heat treatment regimes. The heat treatment of 650 ◦ C/30 min/furnace was used for residual stress reduction and 1050 ◦ C/30 min/furnace was applied for complete structure homogenization. The main findings regarding heat treatment and final materials properties are as follows: The porosities of samples were in the 0.0%–0.08% range and were not affected by heat treatment. The pores were in the form of closed holes filled with unmelted powder particles. There were microcrack formations observed near these pores. Original melt pool reliefs were reduced during 650 ◦ C heat treatment and fully removed at 1050 ◦ C. The microstructure consisted of equiaxial austenitic grains. The structure of the sample heat treated at 1050 ◦ C showed significant grain coarsening. Grains of the non-treated sample treated at 650 ◦C were shown lying within the melt pools and across melt pool boundaries. Open circuit potentials of all samples were elevated during 169 h exposition in saline solution. The most significant shift of OCP to more noble values was noted for the sample after 1050 ◦ C heat treatment.
Materials 2020,13, 1527 17 of 21 The corrosion rate obtained by potentiodynamic polarization method was deeply under the recommended limit. The reference sample demonstrated the most promising results of corrosion rate, especially after 169 h exposure. The highest values of corrosion rate were measured for the sample after 1050 ◦ C heat treatment and after 1 h exposition in saline solution. The signs of corrosion came in the form of the selective dissolving of microstructural components, leaving cellular-like reliefs on the exposed surfaces rather than in the corrosion pits. The sample without heat treatment showed very low grain boundary sensitization, which was furthermore reduced by heat treatment. This was due to long holding times and a slow cooling process. The sample produced by the SLM method indicated nearly doubled surface wettability compared to “standard” ASIS 316L material. This phenomenon is related to higher surface energy and will have a positive effect on biocompatibility. According to these results, SLM stainless steel AISI 316 shows promising properties for manufacturing medical instruments or implants, preferably for short term implantations. It was proven that heat treatment of SLM samples from AISI 316 increases their corrosion rate under the conditions of the human body. According to the results from this study, high temperature heat treatment should not be used for implants with long-term applications, wherein the amount of released ions from corroded material increases with time. Results from this study should be confirmed by clinical tests before their implementation into practice by manufacturing procedures. Author Contributions: Conceptualization, all authors; data curation, M.K. and J.H. (Josef Hlinka); formal analysis, J.H. (Josef Hlinka) and M.P.; investigation, J.H. (Josef Hlinka), J.H. (Jiri Hajnys) and M.K.; methodology J.H. (Josef Hlinka) and M.K.; project administration, M.P.; supervision, J.H. (Josef Hlinka) and M.P.; visualization, J.H. (Josef Hlinka); writing—original draft, J.H. (Josef Hlinka); writing—review and editing, M.K., M.P., J.H. (Jiri Hajnys), Z.B. and T.T. All authors have read and agreed to the published version of the manuscript. Funding: This paper has been completed in connection with project Innovative and additive manufacturing technology—new technological solutions for 3D printing of metals and composite materials, registration number CZ.02.1.01/0.0/0.0/17_049/0008407 financed by Structural Funds of the European Union and project. Conflicts of Interest: The authors declare no conflict of interest. References 1. Frazier, W.E. Metal additive manufacturing: A review. J. Mater. Eng. Perform. 2014 ,23, 1917–1928. [CrossRef] 2. Gao, W.; Zhang, Y.; Ramanujan, D.; Ramani, K.; Chen, Y.; Williams, C.B.; Wang, C.C.L.; Shin, Y.C.; Zhang, S.; Zavattieri, P.D. The status, challenges, and future of additive manufacturing in engineering. Comput. Aided Des. 2015,69, 65–89. [CrossRef] 3. Haleem, A.; Javaid, M. 3D printed medical parts with different materials using additive manufacturing. Clin. Epidemiol. Glob. Health 2019. [CrossRef] 4. Kong, D.; Ni, X.; Dong, C.; Zhang, L.; Man, C.; Yao, J.; Xiao, K.; Li, X. Heat treatment effect on the microstructure and corrosion behavior of 316L stainless steel fabricated by selective laser melting for proton exchange membrane fuel cells. Electrochim. Acta 2018,276, 293–303. [CrossRef] 5. Mercelis, P.; Kruth, J.P. Residual stresses in selective laser sintering and selective laser melting. Rapid Prototyp. J. 2006,12, 254–265. [CrossRef] 6. ASTM Standard F746. Standard Test Method for Pitting or Crevice Corrosion of Metallic Surgical Implant Materials. ASTM B Stand. 2014. [CrossRef] 7. Pardo, A.; Merino, M.C.; Coy, A.E.; Viejo, F.; Arrabal, R.; Matykina, E. Pitting corrosion behaviour of austenitic stainless steels—Combining effects of Mn and Mo additions. Corros. Sci. 2008,50, 1796–1806. [CrossRef] 8. Blinn, B.; Klein, M.; Gläßner, C.; Smaga, M.; Aurich, J.C.; Beck, T. An investigation of the microstructure and fatigue behavior of additively manufactured AISI 316L stainless steel with regard to the influence of heat treatment. Metals 2018,8, 220. [CrossRef] 9. Hlinka, J.; Lasek, S. Influence of Passivation on Wettability of AISI 304 Steel and its Corrosion Properties in Solution of Sodium Hypochlorite. In Key Engineering Materials; Trans Tech Publications Ltd.: Beach, Switzerland, 2019.
Materials 2020,13, 1527 18 of 21 10. Shahryari, A.; Omanovic, S.; Szpunar, J.A. Electrochemical formation of highly pitting resistant passive films on a biomedical grade 316LVM stainless steel surface. Mater. Sci. Eng. C 2008,28, 94–106. [CrossRef] 11. Fathi, M.H.; Doostmohammadi, A. Bioactive glass nanopowder and bioglass coating for biocompatibility improvement of metallic implant. J. Mater. Process. Technol. 2009,209, 1385–1391. [CrossRef] 12. Aghababaie, E.; Javadinejad, H.R.; Saboktakin Rizi, M.; Ebrahimian, M. Effect of Chlorine Ion on the Corrosion of 316L Austenitic Stainless Steel. In Advanced Engineering Forum; Trans Tech Publications Ltd.: Beach, Switzerland, 2017; Volume 23, pp. 1–12. 13. Soltis, J. Passivity breakdown, pit initiation and propagation of pits in metallic materials—Review. Corros. Sci. 2015,90, 5–22. [CrossRef] 14. Strondl, A.; Lyckfeldt, O.; Brodin, H.; Ackelid, U. Characterization and Control of Powder Properties for Additive Manufacturing. JOM 2015,67, 549–554. [CrossRef] 15. Eo, D.R.; Park, S.H.; Cho, J.W. Inclusion evolution in additive manufactured 316L stainless steel by laser metal deposition process. Mater. Des. 2018,155, 212–219. [CrossRef] 16. Koutsoukis, T.; Redjaïmia, A.; Fourlaris, G. Phase transformations and mechanical properties in heat treated superaustenitic stainless steels. Mater. Sci. Eng. A 2013,561, 477–485. [CrossRef] 17. Kong, D.; Dong, C.; Ni, X.; Zhang, L.; Yao, J.; Man, C.; Cheng, X.; Xiao, K.; Li, X. Mechanical properties and corrosion behavior of selective laser melted 316L stainless steel after different heat treatment processes. J. Mater. Sci. Technol. 2019,35, 1499–1507. [CrossRef] 18. Montero-Sistiaga, M.L.; Nardone, S.; Hautfenne, C.; Van Humbeeck, J. Effect of Heat Treatment Of 316L Stainless Steel Produced by Selective Laser Melting (SLM). In Proceedings of the 27th Annual International Solid Freeform Fabrication Symposium—An Additive Manufacturing Conference, Austin, TX, USA, 8–10 August 2016. 19. Sun, Z.; Tan, X.; Tor, S.B.; Chua, C.K. Simultaneously enhanced strength and ductility for 3D-printed stainless steel 316L by selective laser melting. NPG Asia Mater. 2018,10, 127–136. [CrossRef] 20. Yadollahi, A.; Shamsaei, N.; Thompson, S.M.; Seely, D.W. Effects of process time interval and heat treatment on the mechanical and microstructural properties of direct laser deposited 316L stainless steel. Mater. Sci. Eng. A 2015,644, 171–183. [CrossRef] 21. Guitar, M.A.; Scheid, A.; Britz, D.; Mücklich, F. Evaluation of the etching process for analysis of secondary carbides in HCCI by optical and confocal laser microscopy. Pract. Metallogr. 2019,56, 246–261. [CrossRef] 22. Topoglidis, E.; Cass, A.E.G.; O’Regan, B.; Durrant, J.R. Immobilization and bioelectrochemistry of proteins on nanoporous TiO2and ZnO films. J. Electroanal. Chem. 2001,517, 20–27. [CrossRef] 23. Brabec, C.J.; Cravino, A.; Meissner, D.; Serdar Sariciftci, N.; Fromherz, T.; Rispens, M.T.; Sanchez, L.; Hummelen, J.C. Origin of the open circuit voltage of plastic solar cells. Adv. Funct. Mater. 2001 ,11, 374–380. [CrossRef] 24. Enos, D.G.; Scribner, L.L. The Potentiodynamic Polarization Scan; Technical Report; Solartron Instruments: Hampshire, UK, 1997. 25. Kam, D.H.; Bhattacharya, S.; Mazumder, J. Control of the wetting properties of an AISI 316L stainless steel surface by femtosecond laser-induced surface modification. J. Micromech. Microeng. 2012 ,22, 105019. [CrossRef] 26. Calvimontes, A. The Measurement of the Surface Energy of Solids by Sessile Drop Accelerometry. Microgravity Sci. Technol. 2018,30, 277–293. [CrossRef] 27. Cai, X.; Malcolm, A.A.; Wong, B.S.; Fan, Z. Measurement and characterization of porosity in aluminium selective laser melting parts using X-ray CT. Virtual Phys. Prototyp. 2015,10, 195–206. [CrossRef] 28. Mancisidor, A.M.; Garciandia, F.; Sebastian, M.S.; Á lvarez, P.; D í az, J.; Unanue, I. Reduction of the residual porosity in parts manufactured by selective laser melting using skywriting and high focus offset strategies. Phys. Procedia 2016,83, 864–873. [CrossRef] 29. Tammas-Williams, S.; Withers, P.J.; Todd, I.; Prangnell, P.B. The Influence of Porosity on Fatigue Crack Initiation in Additively Manufactured Titanium Components. Sci. Rep. 2017 ,7, 7308. [CrossRef] [PubMed] 30. Sola, A.; Nouri, A. Microstructural porosity in additive manufacturing: The formation and detection of pores in metal parts fabricated by powder bed fusion. J. Adv. Manuf. Process. 2019,1, e10021. [CrossRef] 31. Andreau, O.; Koutiri, I.; Peyre, P.; Penot, J.D.; Saintier, N.; Pessard, E.; De Terris, T.; Dupuy, C.; Baudin, T. Texture control of 316L parts by modulation of the melt pool morphology in selective laser melting. J. Mater. Process. Technol. 2019,264, 21–31. [CrossRef]
Materials 2020,13, 1527 19 of 21 32. Li, Y.; Wang, Z.; Wang, L. Surface properties of nitrided layer on AISI 316L austenitic stainless steel produced by high temperature plasma nitriding in short time. Appl. Surf. Sci. 2014,298, 243–250. [CrossRef] 33. Licausi, M.P.; Igual Muñoz, A.; Amig ó Borr á s, V. Influence of the fabrication process and fluoride content on the tribocorrosion behaviour of Ti6Al4V biomedical alloy in artificial saliva. J. Mech. Behav. Biomed. Mater. 2013,20, 137–148. [CrossRef] 34. Hlinka, J.; Lasek, S. Structure and Corrosion Properties of Electrochemically Treated Surface of 1.4301 (aisi 304) Steel for Medical Applications. In Proceedings of the METAL 2016 25th Anniversary International Conference on Metallurgy and Materials, Brno, Czech Republic, 25–27 May 2016. 35. Eliaz, N. Corrosion of metallic biomaterials: A review. Materials 2019,12, 407. [CrossRef] 36. Kayali, Y.; Büyüksaˇ gi¸s, A.; Güne¸s, I.; Yalçin, Y. Investigation of corrosion behaviors at different solutions of boronized AISI 316L stainless steel. Prot. Met. Phys. Chem. Surf. 2013,49, 348–358. [CrossRef] 37. Kutz, M. Handbook of Environmental Degradation of Materials, 2nd ed.; William Andrew: Norwich, NY, USA, 2012; ISBN 9781437734560. 38. El-Tahawy, M.; Huang, Y.; Um, T.; Choe, H.; L á b á r, J.L.; Langdon, T.G.; Gubicza, J. Stored energy in ultrafine-grained 316L stainless steel processed by high-pressure torsion. J. Mater. Res. Technol. 2017 ,6, 339–347. [CrossRef] 39. Angst, U.; Büchler, M. On the applicability of the Stern-Geary relationship to determine instantaneous corrosion rates in macro-cell corrosion. Mater. Corros. 2015,66, 1017–1028. [CrossRef] 40. Wang, Z.; Di-Franco, F.; Seyeux, A.; Zanna, S.; Maurice, V.; Marcus, P. Passivation-induced physicochemical alterations of the native surface oxide film on 316L austenitic stainless steel. J. Electrochem. Soc. 2019 ,166, C3376–C3388. [CrossRef] 41. Cabrini, M.; Lorenzi, S.; Testa, C.; Brevi, F.; Biamino, S.; Fino, P.; Manfredi, D.; Marchese, G.; Calignano, F.; Pastore, T. Microstructure and selective corrosion of alloy 625 obtained by means of laser powder bed fusion. Materials 2019,12, 1742. [CrossRef] 42. Rahimi, S.; Engelberg, D.L.; Marrow, T.J.; Centre, M.P.; Road, O. Characterization of the Sensitization Behaviour of Thermo-Mechanically Processed Type 304 Stainless Steel Using DL-EPR Testing and Image Analysis Methods. In Proceedings of the 2nd International Conference Corrosion and Material Protection, Prague, Czech Republic, 19–22 April 2010. 43. Amadou, T.; Braham, C.; Sidhom, H. Double loop electrochemical potentiokinetic reactivation test optimization in checking of duplex stainless steel intergranular corrosion susceptibility. Metall. Mater. Trans. A Phys. Metall. Mater. Sci. 2004,35, 3499–3513. [CrossRef] 44. Kubiak, K.J.; Wilson, M.C.T.; Mathia, T.G.; Carval, P. Wettability versus roughness of engineering surfaces. Wear 2011,271, 523–528. [CrossRef] 45. Rabbani, H.S.; Zhao, B.; Juanes, R.; Shokri, N. Pore geometry control of apparent wetting in porous media. Sci. Rep. 2018,8, 15729. [CrossRef] 46. Ali, H.; Ghadbeigi, H.; Mumtaz, K. Effect of scanning strategies on residual stress and mechanical properties of Selective Laser Melted Ti6Al4V. Mater. Sci. Eng. A 2018,712, 175–187. [CrossRef] 47. Jaskari, M.; Mäkikangas, J.; Järvenpää, A.; Mäntyjärvi, K.; Karjalainen, P. Effect of high porosity on bending fatigue properties of 3D printed AISI 316L steel. Procedia Manuf. 2019,36, 33–41. [CrossRef] 48. Fergani, O.; Brotan, V.; Bambach, M.; P é rez-Prado, M.T. Texture evolution in stainless steel processed by selective laser melting and annealing. Mater. Sci. Technol. 2018,34, 2223–2230. [CrossRef] 49. Papula, S.; Song, M.; Pateras, A.; Chen, X.B.; Brandt, M.; Easton, M.; Yagodzinskyy, Y.; Virkkunen, I.; Hänninen, H. Selective laser melting of duplex stainless Steel 2205: Effect of post-processing heat treatment on microstructure, mechanical properties, and corrosion resistance. Materials 2019 ,12, 2468. [CrossRef] [PubMed] 50. Tillmann, W.; Henning, T.; Wojarski, L. Vacuum Brazing of 316L Stainless Steel Based on Additively Manufactured and Conventional Material Grades. In IOP Conference Series: Materials Science and Engineering; IOP Publishing: Bristol, UK, 2018. 51. Cooper, A.J.; Cooper, N.I.; Bell, A.; Dhers, J.; Sherry, A.H. A Microstructural Study on the Observed Differences in Charpy Impact Behavior between Hot Isostatically Pressed and Forged 304L and 316L Austenitic Stainless Steel. Metall. Mater. Trans. A Phys. Metall. Mater. Sci. 2015,46, 5126–5138. [CrossRef] 52. Essa, K.; Jamshidi, P.; Zou, J.; Attallah, M.M.; Hassanin, H. Porosity control in 316L stainless steel using cold and hot isostatic pressing. Mater. Des. 2018,138, 21–29. [CrossRef]
Materials 2020,13, 1527 20 of 21 53. Northcutt, L.A.; Orski, S.V.; Migler, K.B.; Kotula, A.P. Effect of processing conditions on crystallization kinetics during materials extrusion additive manufacturing. Polymer 2018,154, 182–187. [CrossRef] 54. Wu, A.S.; Brown, D.W.; Kumar, M.; Gallegos, G.F.; King, W.E. An Experimental Investigation into Additive Manufacturing-Induced Residual Stresses in 316L Stainless Steel. Metall. Mater. Trans. A Phys. Metall. Mater. Sci. 2014,45, 6260–6270. [CrossRef] 55. Sing, S.L.; An, J.; Yeong, W.Y.; Wiria, F.E. Laser and electron-beam powder-bed additive manufacturing of metallic implants: A review on processes, materials and designs. J. Orthop. Res. 2016 ,34, 369–385. [CrossRef] 56. Wang, Y.M.; Voisin, T.; McKeown, J.T.; Ye, J.; Calta, N.P.; Li, Z.; Zeng, Z.; Zhang, Y.; Chen, W.; Roehling, T.T.; et al. Additively manufactured hierarchical stainless steels with high strength and ductility. Nat. Mater. 2018 , 17, 63–71. [CrossRef] 57. Verlee, B.; Dormal, T.; Lecomte-Beckers, J. Density and porosity control of sintered 316l stainless steel parts produced by additive manufacturing. Powder Metall. 2012,55, 260–267. [CrossRef] 58. Saboori, A.; Toushekhah, M.; Aversa, A.; Lai, M.; Lombardi, M.; Biamino, S.; Fino, P. Critical Features in the Microstructural Analysis of AISI 316L Produced By Metal Additive Manufacturing. Metallogr. Microstruct. Anal. 2020,9, 92–96. [CrossRef] 59. Cherry, J.A.; Davies, H.M.; Mehmood, S.; Lavery, N.P.; Brown, S.G.R.; Sienz, J. Investigation into the effect of process parameters on microstructural and physical properties of 316L stainless steel parts by selective laser melting. Int. J. Adv. Manuf. Technol. 2014,76, 869–879. [CrossRef] 60. Lavery, N.P.; Cherry, J.; Mehmood, S.; Davies, H.; Girling, B.; Sackett, E.; Brown, S.G.R.; Sienz, J. Effects of hot isostatic pressing on the elastic modulus and tensile properties of 316L parts made by powder bed laser fusion. Mater. Sci. Eng. A 2017,693, 186–213. [CrossRef] 61. Espinosa, C.E.; Veleva, L.; L ó pez, J.L. Power spectral density analysis of the corrosion potential fluctuation of stainless steel 316L in early stages of exposure to caribbean sea water. ECS Trans. 2015 ,66, 3–11. [CrossRef] 62. Abosrra, L.; Ashour, A.F.; Mitchell, S.C.; Youseffi, M. Corrosion of mild steel and 316L austenitic stainless steel with different surface roughness in sodium chloride saline solutions. WIT Trans. Eng. Sci. 2009 ,65, 161–172. 63. Mameng, S.H.; Pettersson, R.; Jonson, J.Y. Limiting conditions for pitting corrosion of stainless steel EN 1.4404 (316L) in terms of temperature, potential and chloride concentration. Mater. Corros. 2017 ,68, 272–283. [CrossRef] 64. Manivasagam, G.; Dhinasekaran, D.; Rajamanickam, A. Biomedical Implants: Corrosion and its Prevention—A Review. Recent Patents Corros. Sci. 2010,2, 40–54. [CrossRef] 65. Cabrini, M.; Lorenzi, S.; Pastore, T.; Pellegrini, S.; Burattini, M.; Miglio, R. Study of the corrosion resistance of austenitic stainless steels during conversion of waste to biofuel. Materials 2017,10, 325. [CrossRef] 66. Hadzima, B. Influence of the surface finishing on the corrosion behaviour of AISI 316L stainless steel. Mater. Eng. 2015,22, 48–53. 67. Hiromoto, S. Corrosion of Metallic Biomaterials. In Metals for Biomedical Devices; Woodhead Publishing: Sawston, UK, 2010; pp. 131–152. 68. Baboian, R.; Haynes, G.S. Cyclic Polarization Measurements—Experimental Procedure and Evaluation of Test Data. In Electrochemical Corrosion Testing; ASTM International: West Conshohocken, PE, USA, 1981; pp. 274–282. 69. Yang, K.; Ren, Y. Nickel-free austenitic stainless steels for medical applications. Sci. Technol. Adv. Mater. 2010,11, 014105. [CrossRef] 70. Valente, E.H.; Christiansen, T.L.; Somers, M.A.J. High-Temperature Solution Nitriding and Low-Temperature Surface Nitriding of 3D Printed Stainless Steel. In Proceedings of the 2018 European Conference on Heat Treatment (ECHT), Friedrichshafen, Germany, 12–13 April 2018. 71. Li, Y.J.; Wang, Y.G.; An, B.; Xu, H.; Liu, Y.; Zhang, L.C.; Ma, H.Y.; Wang, W.M. A practical anodic and cathodic curve intersection model to understand multiple corrosion potentials of Fe-based glassy alloys in OH-contained solutions. PLoS ONE 2016,11, e0146421. [CrossRef] 72. Hlinka, J.; Lasek, S.; Siostrzonek, R.; Faisal, N. Characterization of Hydroxyapatite Layer on AISI 316L Stainless Steel. In Proceedings of the 26th International Conference on Metallurgy and Materials (METAL), Brno, Czech Republic, 24–26 May 2017. 73. Bajaj, P.; Hariharan, A.; Kini, A.; Kürnsteiner, P.; Raabe, D.; Jägle, E.A. Steels in additive manufacturing: A review of their microstructure and properties. Mater. Sci. Eng. A 2020,772, 138633. [CrossRef]
Materials 2020,13, 1527 21 of 21 74. Matula, M.; Hyspecka, L.; Svoboda, M.; Vodarek, V.; Dagbert, C.; Galland, J.; Stonawska, Z.; Tuma, L. Intergranular corrosion of AISI 316L steel. Mater. Charact. 2001,46, 203–210. [CrossRef] 75. Stonawsk á , Z.; Svoboda, M.; Soza´nska, M.; Kˇr í stkov á , M.; Sojka, J.; Dagbert, C.; Hyspeck á , L. Structural analysis and intergranular corrosion tests of AISI 316L steel. J. Microsc. 2006 ,224, 62–64. [CrossRef] [PubMed] 76. Terada, M.; Escriba, D.M.; Costa, I.; Materna-Morris, E.; Padilha, A.F. Investigation on the intergranular corrosion resistance of the AISI 316L(N) stainless steel after long time creep testing at 600 ◦ C. Mater. Charact. 2008,59, 663–668. [CrossRef] 77. Gellings, P.J.; de Jongh, M.A. Grain boundary oxidation and the chromium-depletion theory of intercrystalline corrosion of austenitic stainless steels. Corros. Sci. 1967,7, 413–421. [CrossRef] 78. Wei, J.; Igarashi, T.; Okumori, N.; Igarashi, T.; Maetani, T.; Liu, B.; Yoshinari, M. Influence of surface wettability on com petitive protein adsorption and initial attachment of osteoblasts. Biomed. Mater. 2009 ,4, 045002. [CrossRef] 79. Sahoo, N.K.; Anand, S.C.; Bhardwaj, J.R.; Sachdeva, V.P.; Sapru, B.L. Bone Response to Stainless Steel And Titanium Bone Plates: An Experimental Study On Animals. Med. J. Armed Forces India 1994 ,50, 10–14. [CrossRef] 80. Anil, S.; Anand, P.S.; Alghamdi, H.; Janse, J.A. Dental Implant Surface Enhancement and Osseointegration. In Implant Dentistry—A Rapidly Evolving Practice; Intech Open Ltd.: London, UK, 2011. © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).