scieee AI-readable full text Open interactive document viewer

Potential of Near-Infrared Spectroscopy for the Determination of Olive Oil Quality

García-Martín, Juan Francisco

Abstract

The analysis of the physico-chemical parameters of quality of olive oil is still carried out in laboratories using chemicals and generating waste, which is relatively costly and time-consuming. Among the various alternatives for the online or on-site measurement of these parameters, the available literature highlights the use of near-infrared spectroscopy (NIRS). This article intends to comprehensively review the state-of-the-art research and the actual potential of NIRS for the analysis of olive oil. A description of the features of the infrared spectrum of olive oil and a quick explanation of the fundamentals of NIRS and chemometrics are also included. From the results available in the literature, it can be concluded that the four most usual physico-chemical parameters that define the quality of olive oils, namely free acidity, peroxide value, K232, and K270, can be measured by NIRS with high precision. In addition, NIRS is suitable for the nutritional labeling of olive oil because of its great performance in predicting the contents in total fat, total saturated fatty acids, monounsaturated fatty acids, and polyunsaturated fatty acids in olive oils. Other parameters of interest have the potential to be analyzed by NIRS, but the improvement of the mathematical models for their determination is required, since the errors of prediction reported so far are a bit high for practical application.

Full text

  Citation: García Martín, J.F. Potential of Near-Infrared Spectroscopy for the Determination of Olive Oil Quality. Sensors 2022,22, 2831. https:// doi.org/10.3390/s22082831 Academic Editors: Mercedes Del Río Celestino and Rafael Font Villa Received: 18 February 2022 Accepted: 4 April 2022 Published: 7 April 2022 Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. Copyright: © 2022 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/). sensors Review Potential of Near-Infrared Spectroscopy for the Determination of Olive Oil Quality Juan Francisco García Martín1,2 1Departamento de Ingeniería Química, Facultad de Química, Universidad de Sevilla, 41012 Seville, Spain; [email protected] 2University Institute of Research on Olive Groves and Olive Oils, GEOLIT Science and Technology Park, University of Jaén, 23620 Mengíbar, Spain Abstract: The analysis of the physico-chemical parameters of quality of olive oil is still carried out in laboratories using chemicals and generating waste, which is relatively costly and time-consuming. Among the various alternatives for the online or on-site measurement of these parameters, the available literature highlights the use of near-infrared spectroscopy (NIRS). This article intends to comprehensively review the state-of-the-art research and the actual potential of NIRS for the analysis of olive oil. A description of the features of the infrared spectrum of olive oil and a quick explanation of the fundamentals of NIRS and chemometrics are also included. From the results available in the literature, it can be concluded that the four most usual physico-chemical parameters that define the quality of olive oils, namely free acidity, peroxide value, K232, and K270, can be measured by NIRS with high precision. In addition, NIRS is suitable for the nutritional labeling of olive oil because of its great performance in predicting the contents in total fat, total saturated fatty acids, monounsaturated fatty acids, and polyunsaturated fatty acids in olive oils. Other parameters of interest have the potential to be analyzed by NIRS, but the improvement of the mathematical models for their determination is required, since the errors of prediction reported so far are a bit high for practical application. Keywords: chemometrics; olive oil; near-infrared spectroscopy; quality parameters 1. Introduction The International Olive Council defines olive oil as the oil obtained solely from fruits of the olive tree (Olea europaea L.), with the exclusion of oils obtained by solvents or by re-esterification procedures and any mixture with oils of another nature. As stated by this international intergovernmental organisation, the olive oils with the highest quality (socalled virgin oil oils) are those obtained ‘solely by mechanical or other physical means under conditions, particularly thermal conditions, that do not lead to alterations in the oil, and which have not undergone any treatment other than washing, decantation, centrifugation and filtration’ [ 1 ]. Virgin olive oils are classified, in turn, into extra virgin olive oils (EVOO), virgin olive oils (VOO), ordinary virgin olive oil, and lampante virgin olive oil [ 1 , 2 ], where EVOO is the olive oil of the highest quality. While the first three virgin olive oils are fit for consumption, lampante virgin olive oil must undergo processing prior to consumption. Olive oil is regarded as one of the healthiest food oils due to its high content in triglycerides with unsaturated acids, mainly oleic acid, and its phenolic composition. The former is related to a decrease in LDL-cholesterol fraction, while the latter is responsible for the antioxidant properties and the bitter taste of olive oil. Triglycerides account for almost all the saponifiable fraction of the olive oil (roughly 98 wt.%). On the contrary, the phenolic compounds belong to the unsaponifiable fraction, which represents about 2 wt.% of total olive oil. The most representative phenolic compounds in olive oils are oleuropein and hydroxytyrosol. In addition to phenolic compounds, the unsaponifiable fraction is Sensors 2022,22, 2831. https://doi.org/10.3390/s22082831 https://www.mdpi.com/journal/sensors Sensors 2022,22, 2831 2 of 26 composed of a wide variety of compounds, such as triterpenic alcohols, α -tocopherol (vitamin E), γ -tocopherol, β -carotene (precursor substance of vitamin A and responsible for the yellow–orange colour of olive oil), phytosterols, sterols, hydrocarbons, chlorophylls (responsible for the green colour of olive oil), and volatile compounds responsible for the aroma of olive oil. Due to the current popularity of the Mediterranean diet and its use in a wide range of different recipes, the nutritional value of olive oil is internationally recognized today. EVOO is mainly used as a salad dressing and food to be eaten cold due to its flavour and taste. The rest of the edible olive oils are used mostly for cooking. The most common physico-chemical parameters that define the quality of olive oils are the free acidity (FA), the peroxide value (PV), and the absorbency in ultraviolet (at 232 and 270 nm). These three physico-chemical parameters, along with the organoleptic characteristics (odour and taste, defects, fruity attributes, and colour), are used by producers for the determination of the quality of virgin olive oils. Notwithstanding, the International Olive Council establishes additional quality criteria for the designation of olive oils (both edible and non-edible), namely moisture and volatile matter (wt.%), insoluble impurities in light petroleum (wt.%), flash point ( ◦ C), trace metal content (mg/kg of iron and copper), fatty acid ethyl esters content (mg/kg), and biophenols content (mg/kg) [ 1 ]. Generally, olive oil producers do not regard them as quality parameters, but as composition parameters. Additional physico-chemical parameters such as oxidative stability (h), chlorophyll and carotenoid pigment profiles, and the bitterness index are often included [ 2 ]. Regarding organoleptic characteristics, the absence (EVOO) or weak presence (VOO) of sensory defects and the presence of three positive attributes, namely fruitiness, bitterness, and pungency, must be evaluated by skilled tasters. The determination of the aforementioned physico-chemical parameters is currently carried out in a laboratory using chemicals and generating waste, which is relatively costly and time-consuming. In addition, the online determination of the quality parameters of olive oil during the olive oil extraction process in olive mills is not possible using conventional methods. Among the various alternative, non-destructive methods for these analyses, the use of near-infrared (NIR) spectroscopy stands out. Its aim is to correlate the signal of the olive oils in the NIR spectrum with the quality parameters through the use of chemometrics. This article intends to show the state-of-the-art research and the actual potential of near-infrared spectroscopy (NIRS) for the analysis of olive oil, not only its main four quality parameters, but also other parameters of interest for the olive oil industry. For a better understanding, the following three sections include, in the following order, the fundamentals of NIRS, a description of the main features of the NIR spectrum of olive oil, and a brief explanation of what chemometrics is and how it is applied to NIRS, while the last three sections illustrate the results obtained by various authors on the quality parameters, other compounds of interest and sensory attributes, respectively. 2. Near-Infrared Spectroscopy (NIRS) NIR spectroscopy is a vibrational spectroscopy, like Raman spectroscopy. A molecule absorbs NIR radiation (from 800 to 2500 nm) if the energy of the radiation corresponds to the energy difference between two vibrational levels and, in addition, a change occurs in the dipole moment of the molecule [ 3 ]. This is similar to what happens in the mid-infrared region. However, the bands of fundamental vibrations ( ∆ n= ± 1, where nis the vibrational quantum number) do not appear in the NIR spectrum, while absorptions due to the overtones and combination bands are observed. The overtone bands are due to ∆ n> ± 1. Depending on the type of bonds, only the first ( ∆ n= ± 2) and second ( ∆n=±3 ) overtones are likely to be observed. Combination bands occur only in polyatomic molecules and are due to simultaneous changes in the energy of two or more modes of vibration [ 3 , 4 ]. Therefore, the near-infrared spectrum is the result of the change in the molecular dipole moment during vibration. For example, the stretches of C=O in the CO 2 molecule and of O–H in the water molecule, which are polar functional groups, have great absorption in the Sensors 2022,22, 2831 3 of 26 NIR spectrum [ 5 ]. Since the NIR spectrum of an analysed sample is the result of the combinations and overtones of the functional groups of its chemical constituents, the absorption peaks and bands found in the NIR spectrum are generally broad and weak. This makes NIRS more suitable for quantitative analysis than for compound identification (although NIRS can provide some information on functional groups). Hence, NIRS is regarded as a powerful analytical technique for the non-destructive, low-cost, rapid determination of compounds and parameters in food. Since NIR spectroscopy neither requires reagents nor generates waste, other advantages are providing a safe working environment and a huge potential for online measurement. An NIR spectrometer is composed of a radiation source (the most common is a tungsten–filament–fire halogen lamp with quartz window), a wavelength selector (generally a dispersive equipment), a sample holder, and a detector (generally built with semiconductors such as InGaAs and PbS). There are many sample holders depending on how the NIR spectrum is acquired [ 4 ]: transmittance, reflectance, and transflectance (Figure 1). Figure 1. Main configurations to acquire NIR spectra: ( a ) transmittance; ( b ) reflectance; (c) transflectance [4]. The use of cuvettes of different path lengths for transmittance and probes for transflectance is best for homogeneous liquids, while reflectance is generally used for solid, heterogeneous samples. FTIR (Fourier-transform infrared) spectroscopy is an analytical technique generally used to identify functional groups in organic and inorganic compounds by obtaining their infrared spectra in the range of 2500–25,000 nm [ 6 ]. FTIR spectrometers acquire infrared spectra from solid, liquid, or gaseous samples in absorption, total, attenuated, and diffuse reflectance, and photoacoustic modes [ 6 ]. The raw signal is first Fourier-transformed by the equipment. FTIR spectrometers generate a unique type of signal called an interferogram that has all of the infrared wavelengths encoded into it [ 7 ]. Some authors regard the Fourier transform as a type of wavelength selector [ 4 ]. Although it is not the most common, FTIR spectroscopy can be applied to the NIR region, i.e., FTNIR spectroscopy, resulting in a faster NIR spectra acquisition with a higher signal-to-noise ratio than conventional NIRS [ 8 ]. Some works can be found in the literature on the use of FTNIR with olive oils for quantitative or discriminating purposes [9–14]. Since the 1980s, several works have addressed the determination of the main properties of olives of interest to the farmer. An industrial development of NIRS equipment to measure the internal properties of intact olives occurred about 15 years ago, so nowadays it is easy to find commercial equipment to non-destructively measure the moisture and fat content of olives, such as the OliveScan ™ 2 and Olivia ™ equipment (FOSS, Hilleroed, Sensors 2022,22, 2831 4 of 26 Denmark), the Luminar 5030 olive and olive paste analyser (Soluciones Integrales de Laboratorio, S.L., El Casar de Talamanca, Spain), and the NIT-38 olive analyser (NIR Technology Systems, Sidney, Australia). In addition, portable NIR spectrophotometers can be purchased for roughly EUR 6000 (e.g., Flame-NIR spectrometers, Ocean Optics, Inc., Orlando, FL, USA) and could be used at any stage of the olive oil production process. Although they have not been recognized as official methods by the International Olive Council, the determinations of fat content and moisture in olives by NIRS have been accredited as official methods by the pertinent authority of diverse countries. Thus, the accreditations 684/LE937 and 1335/LE2481 issued by the ENAC (Spanish Accreditation Bureau, Madrid, Spain) to various laboratories according to the criteria included in the UNE-EN ISO/IEC 17025:2017 standard [ 15 ], officially allow the determination of total fat and moisture in intact olives by NIRS following an internal method based on the manufacturer’s method FOSS for the Olivia TM equipment (FOSS, Hilleroed, Denmark). Notwithstanding, and despite the large available literature, such industrial development does not exist for the measurement of the quality parameters of olive oil. At the beginning of the twentieth century, several works have addressed the use of NIRS to determine the olive oil quality’s parameters at different points in the oil extraction process in olive mills [ 16 – 18 ]. Thus, NIRS equipment was installed on an olive oil production line, in order to take samples at the exit of the clarifying centrifuge and from the hopper where the oil is continuously weighed, as shown in Figure 2[ 18 ]. Furthermore, NIRS has been applied to design a quality control system for the identification of adulterated olive oils with other oils such as sunflower oil, corn oil, and raw olive waste [ 19 ], and to the differentiation of olive oils that belong to different denominations of origin [ 20 ]. Comprehensive reviews on these latter topics can be found elsewhere [21]. Figure 2. Schematic diagram of the proposed NIRS sensor in the last pass in the olive oil extraction process: (1) oil from horizontal centrifuge decanter; (2) vertical centrifuge for oil clarification; (3) tank for oil sedimentation; (4) continuous oil weigher; (5) to oil storage container; (6) NIRS equipment [ 18 ]. Once experts in the olive oil production process have been consulted, three points within the process, which can be found in Figure 2, seem to be the most suitable for the sampling of olive oils and the on-site determination of their quality parameters by NIRS. The first is at the exit of the horizontal decanter (2- or 3-outlet decanter). However, the samples taken at this point would be more intended for experimental purposes and the enhancement of the process (assessment of temperature of the olive oil in the decanter, etc.), and the values of the quality parameters could not match those of the oil once bottled. The second and third would be at the exit of the vertical centrifuge for oil clarification (or the sedimentation tank if available in the olive mill) and at the olive oil storage containers, Sensors 2022,22, 2831 5 of 26 respectively. Nevertheless, considering that NIRS is a rapid, non-destructive, technique that requires minimal sample preparation (no reagent) and relatively small amounts of a. sample (a few mL of olive oil), experts consider that the most suitable location for the NIRS equipment would be at the bottling plant. In this way, after filling a bottle with olive oil, a small sample would be immediately taken and its NIR spectrum acquired, which would provide the actual values of the quality parameters of the olive oil contained in the bottle. This would also speed up and make the olive oil labelling process more precise, as long as the International Olive Council (or the national quality bureaus) accepts NIRS as an official method for the determination of the olive oil’s quality parameters. However, such types of online proposals have not been, or have been installed only to a limited extent, in olive mills. This is because the development of robust mathematical models is the key to the industrial application of NIRS for online monitoring. These models, previously obtained by using chemometrics, could be the starting point for designing and installing an online tool for the determination of the quality parameters of olive oil on process lines at olive mills, but a full-scale application requires a huge number of samples, not only from the different varieties of olives that the olive mill works with but also over several harvestings in order to develop mathematical models that can be used in a production context. In addition, the chemometric tools of NIRS equipment should provide self-learning model calibration systems. That is to say, the just-acquired spectra directly from the oils in the process line should be automatically included in the calibration data set to strengthen the models by expanding the data sets over time [ 16 ]. In this sense, FOSS annually updates the calibration models of their NIRS equipment to measure properties in intact olives and olive pastes, and customers have to pay to update their equipment if they apply for it. 3. Near-Infrared Spectrum of Olive Oils The sample temperature has a great influence on the NIR radiation that it reflects and absorbs, which makes temperature a parameter of paramount importance in NIRS. For olive oils (and other oils), a sample temperature of approximately 32 ◦ C is usually chosen [ 22 – 28 ]. At this temperature, olive oil is a homogeneous liquid, with a non-important loss of volatile compounds occurring. Therefore, the only sample preparation required in NIRS is heating and maintaining olive oil at that temperature during spectrum acquisition. On the other hand, near-infrared radiation penetrates deeper into organic samples than other electromagnetic radiations, such as ultraviolet (UV), visible, far-infrared, and mid-infrared radiations [ 29 ]. Therefore, the optical path length chosen when acquiring NIR spectra has a significant influence on the radiation absorption intensity at different wavelengths. Figures 3–6show the visible-NIR spectra of 127 olive oils from the variety ‘Picual’ acquired using a Labspec Pro 350-2500P visible/NIR spectrophotometer (Analytical Spectral Devices Inc., Boulder, CO, USA) equipped with three detectors and an operating in transmittance mode. This equipment was used for the spectral acquisition of olive oils in the range 350–2500 nm using quartz cuvettes with different path lengths (from 0.5 to 10 mm) as sample holders. The reflectance was transformed into absorbance. As shown in these figures, the use of cuvettes with higher path lengths for spectral acquisition leads to higher absorbance in the NIR region, thus providing smoother NIR spectra that are more suitable for further building mathematical models for the determination of quality parameters [ 22 ]. In this sense, small differences in path length (0.2 and 0.5 mm) when acquiring the spectra of South African EVOO in the transflectance mode with quartz cuvettes as sample holders have been reported not to have a significant effect on regression model performance [9]. Sensors 2022,22, 2831 6 of 26 Figure 3. Mean-normalized visible/NIR spectra of 127 olive oils obtained with 0.5-mm path-length quartz cuvette [22]. Figure 4. Mean-normalized visible/NIR spectra of 127 olive oils obtained with 2-mm path-length quartz cuvette [22]. Sensors 2022,22, 2831 7 of 26 Figure 5. Mean-normalized visible/NIR spectra of 127 olive oils obtained with 5-mm path-length quartz cuvettes [22]. Figure 6. Mean-normalized visible/NIR spectra of 127 olive oils obtained with 10-mm path-length quartz cuvette [22]. The NIR spectrum of olive oil has previously been described in the literature by various authors [ 21 , 22 , 27 , 29 , 30 ]. In fact, the NIR spectrum of olive oil is quite similar to that of triglycerides, as olive oil is mainly composed of triglycerides [ 31 ]. What is more, as triolein is the main triglyceride and therefore the major component of olive oil, the highest absorption band in the NIR spectrum of olive oil is the same as that of the triolein spectrum, which is observed at 1725 nm [ 29 ]. The two regions of the NIR spectrum that are of great importance [ 31 ] can be clearly observed in Figures 3–6. One is the absorption band near 1720 nm, which is related to the first overtone of the C-H vibration of several chemical groups such as –CH 3 , –CH 2 and =CH 2 , and the other is the absorption peaks at 1660 and 2145 nm, which are related to the C-H vibration of cis-unsaturation. When the degree of cis-unsaturation increases, the absorption peak at 1725 nm (cis-C18:l) shifts to lower Sensors 2022,22, 2831 8 of 26 wavelengths, i.e., to 1717 nm and 1712 nm for cis-C18:2 and cis-C18:3, respectively [ 31 ]. The high adsorption peak at 2145 nm makes the main peaks related to saturated and trans fatty acids, usually observed at 2128 and 2131 nm, respectively, hardly noticeable in the olive oil spectrum [ 29 ]. Wavelengths close to 1800 nm have also been related to the saturated fatty acids [ 29 ]. Finally, a broad absorbance band can be observed at 1210 nm as a result of second overtones of C–H and CH=CH– stretching vibrations [27]. Besides the bands and peaks corresponding to molecules that compose the fatty acids of the olive oil, a broad band at 1400 nm and a broader one at around 1950 nm are also observed in these figures. These bands have been related to the presence of water, to be specific to its first overtone, and to a combination band, respectively [25]. As observed in Figures 3–6, the absorbance in the 2300–2500 nm region is out of the range of the detector used (a holographic fast scanner InGaAs detector, cooled at 25 ◦ C, and coupled with a high-order blocking filter) when increasing the path length of the cuvette (lower radiation transmission and therefore higher absorbance by the olive oil). This problem has also been reported when disposable borosilicate vials were used for the spectral acquisition of olive oil between 400 and 2500 nm in the transmittance mode [ 32 ]. This problem was attributed to the high absorbance of this material. For this reason, quartz cuvettes are the most used and appropriate sample holders for NIRS, since quartz does not absorb radiation in the NIR region [ 21 ]. However, since neither of the two regions of major importance in the NIR spectrum of olive oil falls in this region, the absorbance at wavelengths between 2200 and 2500 nm can be discarded when working with olive oil NIR spectra without losing important information on the sample. Regarding the visible spectrum, it is sometimes used together with the NIR spectrum for the determination of olive oil’s quality parameters. There are three main absorption peaks of olive oil in the visible spectrum. The first is found at 415 nm (dark blue coloured light) and is related to carotenoids, pheophytin a, pheophorbide a, and pyropheophytin a[ 33 ]. The second absorption peak can be observed at 450 nm (blue light), which is characteristic of carotenoids [ 33 ]. The third absorption peak is found at 670 nm, and is related to chlorophylls [ 27 ]. It is worth noting that the two former peaks (between 350 and 500 nm) were easier to differentiate with the 0.5-mm and 2-mm quartz cuvettes ( Figures 3and 4 , respectively) than with the 5-mm path-length cuvette (Figure 5). They could not be clearly distinguished using the 10-mm path-length cuvette (Figure 6), which could indicate that increasing the path length when working in the transmittance mode reduces the quality of the visible spectrum of olive oil. This is contrary to what was found in the NIR spectrum. The features of the visible and NIR spectra of olive oil have been exploited in different ways. For example, the absorbances in the 470–690 nm, 1145–1265 nm, and 1355–1500 nm visible/NIR ranges have been related to olive pomace oil, so these spectral ranges have been used to determine the amount of olive pomace adulterating EVOO with a low standard error of prediction (SEP = 3.27 wt.%) [ 5 ]. Besides, two minor carbonyl absorptions at 1894 and 1930 nm have been used to assess the authenticity of EVOO based on the ratio of absorption intensity at these wavelengths, which are related to the loss of volatiles from EVOO, and therefore to the loss of quality of olive oils [ 11 ]. On the other hand, the use of wavelengths in which the absorption of NIR radiation is related to the structure of fatty acids (aliphatic chains), and therefore responsible for the free acidity of olive oil, resulted in more reliable mathematical models for the determination of free acidity in edible olive oils [22]. 4. Chemometrics Coupled with NIRS Chemometrics is defined as ‘the science of relating measurements made on a chemical system or process to the state of the system via application of mathematical or statistical methods’, according to the International Chemometrics Society [ 34 ]. It started to be applied to spectroscopic data about five decades ago. Chemometrics coupled with NIRS can be defined as the application of statistics and mathematical models to extract the desired Sensors 2022,22, 2831 9 of 26 information from the NIR spectra. The NIR spectra of olive oils are difficult to interpret since they are the result of overlapped overtones and combination bands, which can contain different baselines or noise. The combination of NIRS and chemometrics provides calibration models for olive oil spectra analysis and both classification and discrimination tools. Chemometrics coupled with NIRS are also suitable to handle the dimensional overload, collinearity, spectral interferences, and spectral noise on olive oil NIR spectra. To do this, several specific software has been developed, such as The Unscrambler (CAMO Software AS, Oslo, Norway) or the Chemometrics Toolbox (Eigenvector Research, Inc., Manson, WA, USA) for MatLab (The MathWorks, Inc., Natick, MA, USA), which allow obtaining results with great precision, speed, and comfort. To speed up data evaluation and to increase the precision of the mathematical models, pre-treatments are generally applied to raw spectra, consisting of classical methods for spectral normalization, smoothing, and differentiation [ 35 , 36 ]. Spectra pre-treatments include data spectra derivatization, normalization, baseline correction, standard normal variate, mean centring, Savitzky and Golay smoothing, first and second derivatives and multiplicative scatter corrections [ 8 , 36 – 38 ]. The use of spectra pre-treatments, which at first is an advantage for the use of NIRS for the determination of quality parameters of olive oil, can result in a huge hindrance to the implementation of NIRS for online monitoring or on an industrial scale. For example, when applying a normalization (generally maximum normalization or mean normalization) to olive oil spectra, all available spectra are selected for that normalization, and the normalized spectra are subsequently used to build a calibration method for the determination of one or more olive oil properties via chemometrics. As mentioned above, the chemometric tools coupled with NIRS should provide self-learning calibration models. That is to say, spectra acquired later (e.g., olive oils from next harvestings) must be included in the calibration data set to expand data sets and strengthen models over time [ 16 ]. The problem is that the current set of spectra has already been normalized. The new added spectra cannot be normalized in the same way. At most, all the spectra (old and newly acquired) could be normalized together, but this normalization would be different from the normalization done with the old spectra, thus affecting the later selection of outliers, the developed calibration model, etc. As a result, this kind of pre-treatments would be difficult to implement for an online measurement of olive oil’s quality parameters during olive oil extraction at the olive mills. For olive oils, chemometrics coupled with NIRS are generally used for oil classification (including adulterations) or property quantification. To do this, there are mathematical algorithms that explore the correlation structure within a single data block. For olive oil classification, unsupervised pattern recognition such as principal component analysis (PCA) and supervised pattern recognition such as partial least squares (PLS) combined with discriminant analysis (DA) is the most used chemometric technique [ 36 , 39 ]. Many works can be found in the literature for the detection of adulteration in olive oils using NIRS. Thus, PCA has been applied to detect corn, sunflower, or raw olive residue oils in the range 0–30 wt.% in VOO and EVOO [ 19 ], to detect between 5 and 50 wt.% sunflower, soybean, and sesame oils in VOO [40], and to detect corn, sunflower, soybean, and canola oils in EVOO, with lower limits of adulteration detection of approximately 20, 20, 15, and 10 wt.%, respectively [ 41 ], all of them in the laboratory. The good results obtained in the determination of adulteration in EVOO using PCA and NIRS have led to testing the use of portable NIR spectrometers, which could provide in situ information on adulteration. In this sense, it was proven that the use of PCA and a portable spectrometer, which collected spectra in the range 908 − 1676 nm, resulted in a reliable tool to identify, classify, and quantify the content of different vegetable oils (canola, corn, soybean, and sunflower oil) in EVOO at a confidence level of 95% [ 42 ]. On the other hand, PLS-DA has been applied, for example, to detect corn, hazelnut, soya, and sunflower oils in olive oils [43]. Furthermore, PCA and PLS-DA of olive oil NIR spectra have also been applied to predict the geographical origins of olive oils. For example, 57 EVOO were successfully classified according to their geographical origin (Chianti Classico or Maremma) using different pre-treatments and Sensors 2022,22, 2831 16 of 26 Figure 9. Validation exercise for the determination of the free acidity of olive oil by PLS-NIRS using 85 wavelengths from the NIR spectrum (FA values retrieved from [22]). Table 3. Spectral bands’ tentative assignments correlated to FA of olive oil obtained by the Monte Carlo uninformative variable elimination (MCUVE) method and the successive projections algorithm (SPA). MCUVE (nm) SPA (nm) Bond Vibration Molecule/Compound Reference 1202–1221 - C–H First overtone –CH=CH– [29] C–H Second overtone –CH2[65] 1484–1506 - O–H stretch First overtone Cellulose [65] 1531–1569 - O–H stretch First overtone Starch [65] 1582–1603 - - - - - 1613–1644 - C–H stretch First overtone =CH2[65] -1717–1729 C–H stretch First overtone –CH3[29,65] C–H stretch First overtone - 1751–1763 C–H stretch First overtone –CH2[29,65] 1915–1934 - C=O stretch Second overtone CONH [65] 1957–1973 - O–H stretch O–H bend combination Starch and cellulose [65] 2154–2192 -C–H Asym C–H stretch C–H stretch Combination –CH2[29] C–H deformation combination –HC=CH– [65] C=O stretch combination Protein [65] Combination bands –COOH [66] Finally, some works can be found in the literature on the determination of FA in other IR spectral regions different from the NIR range. For example, the use of FTIR spectroscopy in the infrared spectral region from 5800 to 6075 nm and the wavelength 3308 nm resulted in an R 2cal of 0.99 and a root mean square error of cross-validation of 0.0107% [ 13 ]. However, the calibration model was built with solely a set of 15 samples with FA between 0 and 1%, which were prepared by the gravimetric addition of oleic acid to deodorised olive oil. Sensors 2022,22, 2831 17 of 26 5.2. Peroxide Value (PV) Peroxides are the primary products of the oxidation of olive oil. The peroxide value is a measure of the total peroxides in olive oil expressed as mEq O 2 /kg oil, and therefore a major quality guide. EVOO and VOO cannot exceed the maximum value of 20 mEq O 2 /kg, the limit fixed by the International Olive Council [1]. The reference method consists of dissolving the oil sample in acetic acid and chloroform, adding potassium iodide and subsequent titration with sodium thiosulphate of the liberated iodine [ 60 ]. The precision of the reference method was determined from the results of collaborative tests by the International Olive Council [ 28 ], the reproducibility and repeatability coefficients of variation being 7.1% and 1.9%, respectively, for EVOO, and 13.8% and 3.4% for ordinary olive oils. The standard error of laboratory was reported to be 1.41 meq O2/kg [9]. Table 4illustrates the errors of prediction of PV by NIRS achieved by several authors. As can be seen, most of the SEP values are close to the reported SEL, even though the RPD values are not too high. Therefore, it can be concluded that PV is another olive oil’s quality parameter that can be predicted by NIRS. Table 4. PLS statistics obtained for peroxide value (PV) of olive oils using different PV ranges, visible/NIR spectral intervals, and optical path lengths. PV Range (meq O2/kg) Spectral Acquisition Spectrum (nm) ncal nval Path Length (MM) PC R2cal SEP RPD Reference 2.2–74.0 Transmittance 1100–2500 90 44 0.2 6 0.92 4.15 3.5 [9] 2.2–74.0 Transflectance 1100–2500 90 44 0.6 8 0.87 5.28 2.8 [9] 3.0–32.0 Reflectance 1333–1587 65 14 8.0 12 0.98 1.0 - [12] 5.6−43.9 Transmittance 350–2500 199 46 5.0 - 0.87 3.82 2.8 [27] 1.6–44.5 Transflectance 400–2500 359 100 0.1 - 0.83 1.31 12.0 [30] 2.6–18.0 Transmittance 400–2250 125 - - - 0.92 1.34 22.7 [32] 7.1–75.4 Transmittance 800–2500 60 37 8.0 - 0.92 2.65 31.6 [47] 3.6–8.0 Transmittance 400–1100 34 14 3.0 2 0.83 2.25 33.1 [61] 2.5–17.2 Transmittance 800–2500 14 10 6.5 10 0.94 1.87 3- [62] 0.0–26.7 Transmittance 1000–2222 49 11 - 8 0.84 3.0 41.8 [63] n cal = number of samples in the calibration set; n val = number of samples in the validation set; PC = number of principal components; r 2c , = multiple correlation coefficient of calibration; SEP = standard error of validation; RPD = ratio of performance to deviation. 1 bias-corrected standard error of prediction; 2 standard error of cross validation; 3root mean square error of prediction; 4root mean square error of cross validation. However, when comparing Figure 7with Figure 10, it can be observed that the precision of the determination of the peroxide value by NIRS seems to be lower than that of the free acidity. Figure 10. Validation exercise for the determination of the peroxide value of olive oil by PLS-NIRS using all the wavelengths between 400 and 2500 nm [30]. Sensors 2022,22, 2831 18 of 26 5.3. K270 and K232 The determination of UV-specific extinctions permits an approximation of the oxidation process in unsaturated oils. At 232 nm, primary oxidation products show an absorption (conjugated dienes) that increases due to the defective storage of olive fruits or faulty oil extraction. Secondary oxidation products, such as carbolynic compounds (aldehydes and ketones), are detected at 270 nm, indicating an advanced oxidation process. The maximum permitted values are 2.5 for K232 and 0.20 for K270 [ 1 ]. The extinction coefficients K232 and K270 are measured by UV spectrophotometric analysis at the specific wavelengths of 232 and 270 nm and are expressed in absorbance units (AU). Notwithstanding, their determination has been assayed by NIR and visible/NIR spectroscopy (Tables 5and 6). Table 5. PLS statistics obtained for K232 of olive oils using different K232 ranges, visible/NIR spectral intervals, and optical path lengths. K232 (AU) Spectral Acquisition Spectrum (nm) ncal nval Path Length (mm) PC r2cal SEP RPD Reference 1.7–20.4 Transmittance 1100–2500 70 34 0.2 6 0.94 0.94 3.6 [9] 1.7–20.4 Transflectance 978–2500 70 34 0.6 4 0.87 1.3 2.6 [9] 0.9−5.0 Transmittance 350–2500 223 55 5.0 - 0.82 0.32 2.6 [27] 1.4–5.4 Transflectance 400–2500 359 100 0.1 - 0.75 0.10 11.5 [30] 1.2–2.0 Transmittance 800–2500 60 37 8.0 - 0.40 0.090 21.2 [47] 1.5–3.5 Transmittance 1000–2222 49 11 - 8 0.84 0.27 2,3 1.6 [63] n cal = number of samples in the calibration set; n val = number of samples in the validation set; PC = number of principal components; r 2c = multiple correlation coefficient of calibration; SEP = standard error of validation; RPD = ratio of performance to deviation. 1 bias-corrected standard error of prediction; 2 root mean square error of prediction; 3root mean square error of cross validation. Table 6. PLS statistics obtained for K270 of olive oils using different K270 ranges, visible/NIR spectral intervals and optical path lengths. K270 (AU) Spectral Acquisition Spectrum (nm) ncal nval Path Length (mm) PC r2cal SEP RPD Reference 0.10–2.0 Transmittance 1100–2500 70 34 0.2 6 0.87 0.094 2.5 [9] 0.10–2.0 Transflectance 978–2500 70 34 0.6 3 0.71 0.13 1.8 [9] 0.07–0.41 Transflectance 400–2500 359 100 0.1 - 0.67 0.012 12.2 [30] 0.06–0.17 Transmittance 800–2500 60 37 8.0 - 0.54 0.020 21.2 [47] 0.08–0.21 Transmittance 1000–2222 49 11 - 10 0.74 0.019 31.6 [63] n cal = number of samples in the calibration set; n val = number of samples in the validation set; PC = number of principal components. 1 bias-corrected standard error of prediction; 2 root mean square error of prediction; 3 root mean square error of cross-validation. The standard errors of laboratory for these methods have been reported to be 0.42 and 0.048 for K232 and k270, respectively [ 9 ]. These SEL have been calculated for ranges of values exceeding, by far, the limits established by the International Olive Council. Thus, SEL for K232 (0.42) was provided for samples in the range 1.7–20.4, while the maximum permitted value is 2.5. Similarly, SEL for K270 (0.048) was calculated for samples in the range 0.10–2.0, while the maximum permitted value is 0.2. This could make the comparison between the errors of prediction and SEL difficult. In any case, some of the statistics illustrated in Tables 5and 6show the feasibility of using NIRS to determine K232 and K270. Reference [ 30 ] and, to a lesser extent, reference [ 47 ] show bias-corrected SEP and RMSEP, respectively, suitable for predicting the extinction coefficients by visible/NIR or NIR spectroscopy, respectively. Figures 11 and 12 show the relation between K232 and 270 predicted by NIRS and K232 and 270 analysed by the reference method, as reported in Reference [ 30 ]. Similarly to what was observed for PV, the determination of the specific extinction coefficients by NIRS has lower precision than the determination of FA. It is Sensors 2022,22, 2831 19 of 26 noteworthy that all but one of the RPD values reported in Tables 5and 6are less than 3, which accounts for the poor practical application of this parameter. Figure 11. Validation exercise for the determination of K232 of olive oil by PLS-NIRS using all the wavelengths between 400 and 2500 nm [30]. Figure 12. Validation exercise for the determination of K270 of olive oil by PLS-NIRS using all the wavelengths between 400 and 2500 nm [30]. 6. Other Compounds In addition to the four basic quality physico-chemical parameters of olive oil, several other compounds and parameters of olive oil have been assayed to be quantified by NIRS (Table 7). The RPD values reported by the different authors on the various parameters are generally low, but RPD is not considered in the discussion of the statistics collected in Table 7to the problems that its interpretation presents, as has been pointed out in the previous sections. For most of these parameters, the authors did not provide SEL, so the Sensors 2022,22, 2831 20 of 26 most suitable approach to assess the feasibility of NIRS to predict these parameters is then to compare the error of prediction with the unit range of these parameters for olive oils. Table 7. PLS statistics obtained for different compounds and parameters of olive oils using different unit ranges, visible/NIR spectral intervals, and optical path lengths. Parameter Units Range Spectral Acquisition Spectrum (nm) ncal nval Path Length (mm) PC r2cal SEP RPD Reference K225 AU 0.06–0.66 Transmittance 1100–2500 149 30 1.0 13 0.87 0.058 - [18] Carotenoids mg/kg 1.6–18.1 Transmittance 450–2500 151 32 1.0 4 0.985 0.66 - [17] Carotenoids mg/kg 0.12–13.1 Transmittance 1100–2500 64 32 0.2 5 0.66 1.1 1.7 [9] Carotenoids mg/kg 0.12–13.1 Transflectance 978–2500 64 32 0.6 3 0.52 1.4 1.4 [9] Carotenoids mg/kg 2.1–38.5 Transmittance 1100–2500 205 50 5.0 - 0.62 - - [46] Carotenoids mg/kg 2.1–38.5 Transmittance 350–2500 205 50 5.0 - 0.95 1.8 3.9 [46] Chlorophylls mg/kg 0.7–27.5 Transmittance 450–2500 151 32 1.0 4 0.993 0.96 - [17] Chlorophylls mg/kg 0.082–25.2 Transmittance 1100–2500 65 32 0.2 8 0.56 3.6 1.5 [9] Chlorophylls mg/kg 0.082–25.2 Transflectance 978–2500 65 32 0.6 3 0.31 4.4 1.2 [9] Chlorophylls g/kg 0–14.5 Transmittance 400–2250 168 - - - 0.98 0.51 15.6 [32] Chlorophylls mg/kg 1.4–88.1 Transmittance 1100–2500 205 53 5.0 - 0.56 - - [46] Chlorophylls mg/kg 1.4–88.1 Transmittance 350–2500 205 53 5.0 - 0.96 3.5 4.1 [46] Alkyl esters mg/kg 3–610 Transflectance 400–2500 359 100 0.1 - 0.79 19.5 21.9 [30] Ethyl esters mg/kg 1–461 Transflectance 400–2500 359 100 0.1 - 0.80 14.2 21.9 [30] Moisture wt.% 0.01−0.63 Transflectance 400–2500 283 66 0.1 - 0.71 0.04 21.5 [30] Total polyphenols mg/kg 44.5–738.8 Transmittance 1100–2500 67 31 0.2 2 0.21 89.7 1.1 [9] Total polyphenols mg/kg 44.5–738.8 Transflectance 978–2500 67 31 0.6 2 0.34 82.1 1.2 [9] Total polyphenols mg/kg 110.7–594.0 Transmittance 800–2500 60 37 0.8 - 0.85 44.5 31.7 [47] Squalene g/kg 1.0−10.1 Transflectance 1100–2300 118 59 - - 0.86 1.2 2.3 [23] Squalene g/kg 1.0−10.1 Transmittance 350–2500 118 59 10.0 - 0.76 1.0 1.9 [23] α-tocopherol mg/kg 54.5–755.9 Transflectance 1100–2300 218 109 10.0 0.95 47.2 2.4 [25] α-tocopherol mg/kg 54.5–755.9 Transmittance 350–2500 218 109 10.0 0.94 58.3 1.9 [25] α-tocopherol mg/kg 91.0–249.3 Transmittance 800–2500 60 37 0.8 - 0.71 15.2 31.3 [47] β-tocopherol mg/kg 0.5–14.1 Transflectance 1100–2300 218 109 10.0 0.64 1.4 1.0 [25] β-tocopherol mg/kg 0.5–14.1 Transmittance 350–2500 218 109 10.0 0.66 1.3 1.1 [25] β-tocopherol mg/kg 9.11–17.2 Transmittance 800–2500 60 37 0.8 - 0.42 1.5 31.0 [47] γ-tocopherol mg/kg 1.8–103.8 Transflectance 1100–2300 218 109 10.0 0.92 6.3 1.9 [25] γ-tocopherol mg/kg 1.8–103.8 Transmittance 350–2500 218 109 10.0 0.87 8.1 1.5 [25] γ-tocopherol mg/kg 10.7–36.6 Transmittance 800–2500 60 37 0.8 - 0.63 2.2 31.2 [47] Total tocopherol mg/kg 63.1–1078.0 Transflectance 1100–2300 218 109 10.0 0.92 61.8 2.0 [25] Total tocopherol mg/kg 63.1–1078.0 Transmittance 350–2500 218 109 10.0 0.91 76.2 1.6 [25] Total tocopherol mg/kg 110.8–278.8 Transmittance 800–2500 60 37 0.8 - 0.61 19.3 31.2 [47] Oxidative stability h 15.2−90.6 Transmittance 350–2500 133 43 5.0 - 0.94 7.4 3.0 [27] n cal = number of samples in the calibration set; n val = number of samples in the validation set; PC = number of principal components; r 2c = multiple correlation coefficient of calibration; SEP = standard error of validation; RPD = ratio of performance to deviation. 1 standard error of cross validation; 2 bias-corrected standard error of prediction; 3root mean square error of prediction. The UV absorbance at K225 is an index of oil bitterness. High bitterness in olive oils is not well accepted by consumers [ 18 ]. Using 13 PC, an R 2cal of 0.870 and an SEP of 0.058 were obtained for this parameter (Table 7), with SEL = 0.026 [18]. For carotenoid and chlorophyll pigments in VOO, Jiménez Marquez [ 17 ] concluded that his results showed similarities between visible-near infrared transmittance spectroscopy and reference laboratory methods. The SEL for chlorophylls was 0.25 mg/kg, while SEL for carotenes was 0.35 mg/kg for the ranges indicated in Table 7, with SEP being slightly superior to SEL [ 17 ]. The standard error of the laboratory depends on many factors. The range of concentrations used can be highlighted. In this sense, other authors have found that SEL was 0.23 mg/kg for carotenoids in the range 0.12–13.13 mg/kg, and 0.47 mg/kg for chlorophylls in the range 0.082–25.23 mg/kg [ 9 ]. Of note is that β -carotene is the precursor substance of vitamin A and is responsible for the yellow–orange colour of olive oil, while chlorophylls are responsible for the green colour of olive oil. Therefore, both absorb radiation mainly in the visible spectrum. One could ask why one would determine these compounds by NIRS, since they absorb mainly in the visible spectrum and, as for the K225, K232 and K270 parameters, Sensors 2022,22, 2831 21 of 26 ultraviolet radiation. As stated in Section 3, the peaks observed at 420 and 460 nm in the olive oil spectrum correspond mainly to carotenoids, while the peak at approximately 670 nm corresponds to chlorophyll absorption [ 33 ]. This was the reason why the PLS models built solely with the NIR spectrum (Table 7) achieved maximum R 2cal of 0.66 and 0.56 for carotenoids and chlorophylls, respectively, which are too low for practical use [ 9 , 46 ]. For this reason, NIRS (or visible/NIR spectroscopy) should be implemented as a multiparametric tool, i.e., not only to determine a property of olive oil, but as many parameters as possible from its NIR (or visible/NIR) spectral information. The idea is to find out the composition and quality parameters of olive oil by simply acquiring its NIR or visible/NIR spectrum in a few seconds. This is the main advantage of NIRS when compared to the laborious, time-consuming reference methods that have to be individually carried out in the laboratory for each quality parameter of olive oil. Alkyl esters in olive oils are derived from the non-desired fermentation of the fruit, normally when overripe or incorrectly stored, thus suffering damage in the cell structure prior to entering the olive oil processing. The most important quality of olive oil is the number of ethyl esters, which is regarded as a quality criterion by the International Olive Council. The content of fatty acid ethyl esters must be ≤ 35 mg/kg for an oil to be classified as EVOO [ 1 ]. The SEP illustrated in Table 7for ethyl esters (14.2 mg/kg) [ 30 ] seems to be a bit excessive to meet the requirements of the International Olive Council. Moisture, which can promote the rancidification of olive oil, leading to an unpleasant taste and an unpleasant odour, has been determined by PLS-NIRS to achieve an r 2cal of 0.71 and a bias-corrected SEP of 0.04 wt.% [30]. Taking into account that the moisture and volatile matter content is another quality criterion of the International Olive Council, and it must be ≤ 0.2 wt.% for edible olive oils [ 1 ], this prediction error should be lowered a bit. The relation between analysed and predicted values obtained by these authors is illustrated in Figure 13. It is worth noting that the determination of water content in olive oils by NIRS has not been assayed to date by using only the wavelengths where the broad absorption bands of water are found (at 1400 and 1950 nm). Figure 13. Validation exercise for the determination of the moisture and volatile matter content of olive oil by PLS-NIRS using all the wavelengths between 400 and 2500 nm [30]. Parameters such as total polyphenols have not been successfully predicted by NIRS. In this sense, SEPs of 82.10 and 89.66 mg/kg were obtained when analysing total polyphenols in EVOO using two spectrometers, SEL being 9.24 mg/kg for samples in the range 44.49–738.76 mg/kg [ 9 ]. Other authors achieved a good correlation coefficient of calibration Sensors 2022,22, 2831 22 of 26 (r 2cal = 0.85) and a lower error of prediction (RMSEP = 44.5 mg/kg) [ 47 ], but these were still a bit high for practical use. Squalene is a hydrocarbon that can be found in relatively high quantities (between 60 and 75 wt.% ) within the unsaponifiable fraction of olive oil, accounting for between 0.2 and 7.5 g/kg of olive oil [ 67 ]. In spite of the multiple pieces of scientific evidence of the beneficial effects of squalene on human health, its determination is generally not performed in the olive oil industry, as squalene is neither considered a quality nor a purity parameter in olive oil regulation [ 1 ]. The only attempt found in the literature to determine squalene in olive oil by NIRS or visible/NIR spectroscopy used EVOO, VOO, ordinary oil oils, pomace oils, and lampante oils of different varieties for the calibration and validation exercises [ 23 ]. The best results were obtained with the NIR spectra (Table 7). However, the SEP achieved (1 g/kg) is too high for its use in the olive oil industry since, as aforementioned, the concentration of squalene in olive oils ranges between 0.2 and 7.5 g/kg olive oil. Olive oil is a notorious source of vitamin E ( α -tocopherol). EVOO and VOO contain about 207.3mg α -tocopherol per kg of olives. Pomace olive oils contain higher amounts of vitamin E, up to 981.6 mg/kg [ 68 ]. The determination of α -tocopherol, β -tocopherol, γ -tocopherol and total tocopherols of olive oils has been assayed using their NIR and visible/NIR spectra [ 25 ]. In that work, lampante and pomace olive oils were used in the calibration PLS models along with EVOO and VOO to increase the diversity of tocopherols, so that the range of concentrations of α -tocopherol (Table 7) was much higher than the content of α -tocopherol reported for EVOO and VOO [ 68 ]. Models using only NIR wavelengths predicted the content in α -, γ - and total tocopherols better than those using all wavelengths from the visible/VIR spectrum [ 25 ]. The PLS-NIR model for α -tocopherol achieved a good correlation coefficient of calibration (0.95), but SEP (47.2 mg/kg) seems to be quite high for practical application, taking into account that the average content of vitamin E in olive oils is 207.3 mg/kg [ 68 ]. The statistics found by other authors did not improve the ability of NIRS to determine α-tocopherol in olive oils [47]. Finally, other parameters of interest for the quality of olive oil, such as the oxidative stability, for which the units are time-based, have been predicted by visible/NIR spectroscopy with relatively good precision [27], as illustrated in Table 7. On the other hand, olive oil is practically composed of fat (the saponifiable fraction accounts for roughly 98 wt.% olive oil). The fatty acid profile of olive oils is one of the most suitable and with the highest precision analysis that NIRS can perform [ 10 , 18 , 31 , 32 , 69 ]. The current European regulation settles the obligation of food manufacturers to include nutritional information on their product labels [ 26 ]. Mandatory information on food labels includes energy value, total fat content, total saturated fatty acids (TSFA), and other compounds that olive oil does not contain, such as carbohydrates, sugars, proteins, and salt. As voluntary nutritional information, the European label can contain other nutritional information, such as monounsaturated fatty acids (MUFA) and polyunsaturated fatty acid (PUFA) content. Furthermore, food labelling regulations in the USA and Canada also require a declaration of TSFA content on product labels [ 10 ]. Regarding olive oil, the most frequently included information on its nutritional label is total fat, saturated fat, monounsaturated fat, and polyunsaturated fat [ 26 ]. It has been reported that the first overtone of MUFA can be observed at 1724 and 1766 nm, with the combination bands at 2358 nm [ 29 ]. As for PUFA, 1660, 1698, and 1730 nm wavelengths have correlated with the first overtone, 1162 and 1212 nm with the second overtone, and 2136, 2176, 2224, 2310, 2348, and 2434 nm with combination bands [ 29 ]. Some works available in the literature have shown the feasibility of NIRS for determining TSFA, MUFA, and PUFA in the American, Canadian, Spanish, and Portuguese EVOO, VOO, and ordinary olive oils [ 10 , 14 , 26 , 47 ]. Hence, NIRS is suitable for the nutritional labelling of olive oil. 7. Sensory Attributes The sensory parameters of olive oil are of equal importance as the physico-chemical quality parameters described in Section 5. Notwithstanding, scarce information can be Sensors 2022,22, 2831 23 of 26 found in the literature on the use of NIRS for the determination of the sensory parameters of olive oil. The prediction of the minor composition of VOO, in particular its phenolic and volatile compounds, as well as its organoleptic attributes, has been assayed in the 800–2500 nm NIR spectrum. Acceptable multivariate algorithms based on the multiple coefficient of determination were obtained for some minor components, such as hydroxytyrosol derivatives (r2= 0.86–0.88) and C6 alcohols (r2= 0.69–0.80), and for positive sensory attributes such as ‘fruity’ (r 2 = 0.87) and ‘bitter’ (r 2 = 0.85) [ 47 ]. More research is needed to correlate the NIR spectra of olive oil with its sensory parameters before regarding NIRS as a potential tool for the determination of these parameters. 8. Conclusions The information available in the literature illustrates that the application of NIRS to olive oil could undergo an industrial development similar to that of olives and olive pastes, which have commercial, available NIRS equipment for assessing some of its main parameters of interest. A sampling system of olive oils and NIRS equipment for the acquisition of their NIR spectra could be implemented in the olive oil mill or in the bottling plant, thus allowing the on-site determination of their main quality parameters. The four primary olive oils’ quality parameters (FA, PV, K232 and K270) can be accurately determined by NIRS spectroscopy, based on promising results reported by different authors. In addition, NIRS is suitable for the nutritional labelling of olive oil, since its feasibility for determining TSFA, MUFA, and PUFA has been demonstrated. Therefore, all these parameters in an olive oil could be measured by NIRS, as a multiparametric analytical technique, simply by acquiring the NIR spectrum of the oil and using the PLS model developed for each parameter. Other parameters such as α -tocopherol (vitamin E), fatty acid ethyl esters, squalene and K225 show potential to be determined by NIRS, but the prediction errors reported by the various authors are still a bit high for practical application. Furthermore, by expanding the wavelength range to which spectra are acquired to the visible region, other compounds such as carotenoids and chlorophylls, which absorb radiation mainly in the visible spectrum, could be quantified by visible/NIR spectroscopy. However, visible/NIR spectrophotometers are more expensive than NIR spectrophotometers, so the implementation of one or another will depend on the robustness of the PLS models for each parameter and, hence, their practical application. NIRS equipment at olive oil mills or bottling plants should provide self-learning model calibration systems, so that samples from new harvestings, different designations, geographical origin, and varieties, etc. are automatically added to the calibration set to strengthen the PLS models over time. Validation exercises with samples not used to build the PLS models are mandatory to assess their performance. Spectra pre-treatments (derivatisation, normalisation, baseline correction, standard normal variate, mean centring, Savitzky and Golay smoothing, first and second derivatives, multiplicative scatter corrections) enhance the handling of the spectra and the building of the PLS calibration models. Similarly, the selection of actual contributing spectral variables and the removal of outliers can improve the performance of the PLS models. Notwithstanding, these latter two procedures must be carefully performed or avoided at early stages of the model building (when there is not a large calibration sample set) due to the risk of removing important spectral information related to the quality parameter of interest. The ultimate goal is to achieve acceptance of NIRS as an official method for the determination of the quality parameters and the nutritional parameters for the labelling of olive oil by the relevant national authorities and, as a priority, the International Olive Council, which will greatly contribute to the industrial development of NIRS equipment for the olive oil industry. Sensors 2022,22, 2831 24 of 26 Funding: This research received no external funding. Institutional Review Board Statement: Not applicable. Acknowledgments: The author would like to earnestly thank JoséM. García-Martos and Fernando Martínez-Román, both from the Instituto de la Grasa of the Spanish National Research Council, for their insightful suggestions and reassurance. Conflicts of Interest: The author declares no conflict of interest. References 1. Trade Standard Applying to Olive Oils and Olive Pomace Oils. Rev. 13; International Olive Council: Madrid, Spain, 2019. 2. Plasquy, E.; García Martos, J.M.; Florido, M.C.; Sola-Guirado, R.R.; García Martín, J.F. Cold storage and temperature management of olive fruit: The impact on fruit physiology and olive oil quality—A review. Processes 2021,9, 1543. [CrossRef] 3. Siesler, H.W. Basic Principles of Near-Infrared Spectroscopy. In Handbook of Near-Infrared Analysis; Burns, D.A., Ciurczak, E.W., Eds.; CRC Press: Boca Raton, FL, USA, 2007. 4. Peguero Gutiérrez, A. La Espectroscopía NIR en la Determinación de Propiedades Físicas y Composición Química de Intermedios de Producción y Productos Acabados. Ph.D. Thesis, Universitat Autònoma de Barcelona, Barcelona, Spain, 2010. 5. Yang, H.; Irudayaraj, J. Comparison of near-infrared, Fourier transform-infrared, and Fourier transform-Raman methods for determining olive pomace oil adulteration in extra virgin olive oil. J. Am. Oil Chem. Soc. 2001,78, 889–895. [CrossRef] 6. Berna, F. Fourier transform infrared spectroscopy (FTIR). In Encyclopedia of Earth Sciences Series; Gilbert, A.S., Ed.; Springer: Dordrecht, The Netherlands, 2017; pp. 285–286. 7. Thermo Fisher Scientific. Advantages of Fourier-Transform Near-Infrared Spectroscopy; Thermo Fisher Scientific Inc.: Madison, WI, USA, 2006. 8. Rohman, A. Infrared spectroscopy for quantitative analysis and oil parameters of olive oil and virgin coconut oil: A review. Int. J. Food Prop. 2017,20, 1447–1456. [CrossRef] 9. Manley, M.; Eberle, K. Comparison of Fourier transform near infrared spectroscopy partial least square regression models for South African extra virgin olive oil using spectra collected on two spectrophotometers at different resolutions and path lengths. J. Near Infrared Spectrosc. 2006,14, 111–126. [CrossRef] 10. Mossoba, M.M.; Azizian, H.; Tyburczy, C.; Kramer, J.K.G.; Delmonte, P.; Kia, A.R.F.; Rader, J.I. Rapid FT-NIR analysis of edible oils for total SFA, MUFA, PUFA, and trans FA with comparison to GC. J. Am. Oil Chem. Soc. 2013,90, 757–770. [CrossRef] 11. Azizian, H.; Dugan, M.E.R.; Kramer, J.K.G. Clarifications of the carbonyl and water absorptions in Fourier transform near infrared spectra from extra virgin olive oil. Eur. J. Lipid Sci. Technol. 2021,123, 2000288. [CrossRef] 12. Lagardere, L.; Lechat, H.; Lacoste, F. Détermination de l’aciditéet de l’indice de peroxyde dans les huiles d’olive vierges et dans les huiles raffinées par spectrométrie proche infrarouge àtransformée de Fourier. Oléagineux Corp. Gras Lipides 2004 ,11, 70–75. [CrossRef] 13. Tarhan, ˙ I.; Ismail, A.A.; Kara, H. Quantitative determination of free fatty acids in extra virgin olive oils by multivariate methods and Fourier transform infrared spectroscopy considering different absorption modes. Int. J. Food Prop. 2017 ,20, S790–S797. [CrossRef] 14. Milinovic, J.; Garcia, R.; Rato, A.E.; Cabrita, M.J. Rapid assessment of monovarietal Portuguese extra virgin olive oil’s (EVOO’s) fatty acids by Fourier-transform near-infrared spectroscopy (FT-NIRS). Eur. J. Lipid Sci. Technol. 2019,121, 1800392. [CrossRef] 15. ISO/IEC 17025; Requisitos Generales Para la Competencia de los Laboratorios de Ensayo y Calibración. Asociación Española de Normalización: Madrid, Spain, 2017. 16. Giovenzana, V.; Beghi, R.; Romaniello, R.; Tamborrino, A.; Guidetti, R.; Leone, A. Use of visible and near infrared spectroscopy with a view to on-line evaluation of oil content during olive processing. Biosyst. Eng. 2018,172, 102–109. [CrossRef] 17. Márquez, A.J. Monitoring Carotenoid and Chlorophyll Pigments in Virgin Olive Oil by Visible-Near Infrared Transmittance Spectroscopy. On-Line Application. J. Near Infrared Spectrosc. 2003,11, 219–226. [CrossRef] 18. Marquez, A.J.; Díaz, A.M.; Reguera, M.I.P.P. Using optical NIR sensor for on-line virgin olive oils characterization. Sens. Actuators B Chem. 2005,107, 64–68. [CrossRef] 19. Wesley, I.J.; Barnes, R.J.; McGill, A.E.J. Measurement of adulteration of olive oils by near infra-red spectroscopy. J. Am. Oil Chem. Soc. 1995,72, 289–292. [CrossRef] 20. Bertran, E.; Blanco, M.; Coello, J.; Iturriaga, H.; Maspoch, S.; Monteliu, I. Near infrared spectrometry and pattern recognition as screening methods for the authentication of virgin olive oils of very close geographical origins. J. Near Infrared Spectrosc. 2000 , 8, 45–52. [CrossRef] 21. Casale, M.; Simonetti, R. Review: Near infrared spectroscopy for analysing olive oils. J. Near Infrared Spectrosc. 2014 ,22, 59–80. [CrossRef] 22. García Martín, J.F. Optical path length and wavelength selection using Vis/NIR spectroscopy for olive oil’s free acidity determination. Int. J. Food Sci. Technol. 2015,50, 1461–1467. [CrossRef] 23. Cayuela, J.A.; García, J.F. Nondestructive measurement of squalene in olive oil by near infrared spectroscopy. LWT Food Sci. Technol. 2018,88, 103–108. [CrossRef] Sensors 2022,22, 2831 25 of 26 24. Cayuela, J.A.; García, J.M.; Caliani, N. NIR prediction of fruit moisture, free acidity and oil content in intact olives. Grasas Aceites 2009,60, 194–202. [CrossRef] 25. Cayuela, J.A.; García, J.F. Sorting olive oil based on alpha-tocopherol and total tocopherol content using near-infra-red spectroscopy (NIRS) analysis. J. Food Eng. 2017,202, 79–88. [CrossRef] 26. Cayuela-Sánchez, J.A.; Palarea-Albaladejo, J.; García-Martín, J.F.; Del Carmen Pérez-Camino, M. Olive oil nutritional labeling by using Vis/NIR spectroscopy and compositional statistical methods. Innov. Food Sci. Emerg. Technol. 2019 ,51, 139–147. [CrossRef] 27. Cayuela Sánchez, J.A.; Moreda, W.; García, J.M. Rapid determination of olive oil oxidative stability and its major quality parameters using vis/NIR transmittance spectroscopy. J. Agric. Food Chem. 2013,61, 8056–8062. [CrossRef] [PubMed] 28. Cayuela, J.A. Assessing olive oil peroxide value by NIRS, and on reference methods. NIR News 2017,28, 12–16. [CrossRef] 29. García-González, D.L.; Baeten, V.; Fernández Pierna, J.A.; Tena, N. Infrared, raman, and fluorescence spectroscopies: Methodologies and applications. In Handbook of Olive Oil: Analysis and Properties; Springer: Boston, MA, USA, 2013; pp. 335–393; ISBN 9781461477778. 30. Garrido-Varo, A.; Sánchez, M.T.; De la Haba, M.J.; Torres, I.; Pérez-Marín, D. Fast, low-cost and non-destructive physico-chemical analysis of virgin olive oils using near-infrared reflectance spectroscopy. Sensors 2017,17, 2642. [CrossRef] [PubMed] 31. Sato, T.; Kawano, S.; Iwamoto, M. Near infrared spectral patterns of fatty acid analysis from fats and oils. J. Am. Oil Chem. Soc. 1991,68, 827–833. [CrossRef] 32. Mailer, R.J. Rapid evaluation of olive oil quality by NIR reflectance spectroscopy. J. Am. Oil Chem. Soc. 2004 ,81, 823–827. [CrossRef] 33. Moyano, M.J.; Meléndez-Martínez, A.J.; Alba, J.; Heredia, F.J. A comprehensive study on the colour of virgin olive oils and its relationship with their chlorophylls and carotenoids indexes (I): CIEXYZ non-uniform colour space. Food Res. Int. 2008 , 41, 505–512. [CrossRef] 34. Moros, J.; Garrigues, S.; De la Guardia, M. Vibrational spectroscopy provides a green tool for multi-component analysis. Trends Anal. Chem. 2010,29, 578–591. [CrossRef] 35. Gabrielsson, J.; Trygg, J. Recent developments in multivariate calibration. Crit. Rev. Anal. Chem. 2006,36, 243–255. [CrossRef] 36. Miller, J.N.; Miller, J.C. Statistics and Chemometrics for Analytical Chemistry, 6th ed.; Pearson Education Limited: Harlow, UK, 2010; ISBN 978-0-273-73042-2. 37. Beebe, K.R.; Kowalski, B.R. An introduction to multivariate calibration and analysis. Anal. Chem. 1987 ,59, 1007A–1017A. [CrossRef] 38. Guzmán Jiménez, E. Desarrollo de Técnicas Ópticas de Análisis Rápido Para el Control de Calidad en el Proceso de Elaboración de Aceite de Oliva Virgen. Ph.D. Thesis, Universidad de Córdoba, Córdoba, Spain, 2013. 39. Kaufmann, K.C.; Sampaio, K.A.; García-Martín, J.F.; Barbin, D.F. Identification of coriander oil adulteration using a portable NIR spectrometer. Food Control 2022,132, 108536. [CrossRef] 40. Weng, X.-X.; Lu, F.; Wang, C.-X.; Qi, Y.-P. Discriminating and quantifying potential adulteration in virgin olive oil by near infrared spectroscopy with BP-ANN and PLS. Spectrosc. Spectr. Anal. 2009,29, 3283–3287. [CrossRef] 41. Vanstone, N.; Moore, A.; Martos, P.; Neethirajan, S. Detection of the adulteration of extra virgin olive oil by near-infrared spectroscopy and chemometric techniques. Food Qual. Saf. 2018,2, 189–198. [CrossRef] 42. Borghi, F.T.; Santos, P.C.; Santos, F.D.; Nascimento, M.H.C.; Corrêa, T.; Cesconetto, M.; Pires, A.A.; Ribeiro, A.V.F.N.; Lacerda, V.; Romão, W.; et al. Quantification and classification of vegetable oils in extra virgin olive oil samples using a portable near-infrared spectrometer associated with chemometrics. Microchem. J. 2020,159, 105544. [CrossRef] 43. Kasemsumran, S.; Kang, N.; Christy, A.; Ozaki, Y. Partial least squares processing of near-infrared pectra for discrimination and quantification of adulterated olive oils. Spectrosc. Lett. 2005,38, 839–851. [CrossRef] 44. Casale, M.; Oliveri, P.; Casolino, C.; Sinelli, N.; Zunin, P.; Armanino, C.; Forina, M.; Lanteri, S. Characterisation of PDO olive oil Chianti Classico by non-selective (UV–visible, NIR and MIR spectroscopy) and selective (fatty acid composition) analytical techniques. Anal. Chim. Acta 2012,712, 56–63. [CrossRef] 45. Galtier, O.; Dupuy, N.; Le Dréau, Y.; Ollivier, D.; Pinatel, C.; Kister, J.; Artaud, J. Geographic origins and compositions of virgin olive oils determinated by chemometric analysis of NIR spectra. Anal. Chim. Acta 2007,595, 136–144. [CrossRef] 46. Cayuela, J.A.; Yousfi, K.; Carmen Martínez, M.; García, J.M. Rapid determination of olive oil chlorophylls and carotenoids by using visible spectroscopy. J. Am. Oil Chem. Soc. 2014,91, 1677–1684. [CrossRef] 47. Inarejos-García, A.M.; Gómez-Alonso, S.; Fregapane, G.; Salvador, M.D. Evaluation of minor components, sensory characteristics and quality of virgin olive oil by near infrared (NIR) spectroscopy. Food Res. Int. 2013,50, 250–258. [CrossRef] 48. López Barrera, M.D.C. Caracterización de Aceites Usados de HORECA Mediante Métodos Tradicionales y Espectroscopía de Infrarrojo Cercano. Bachelor’s Thesis, Universidad de Sevilla, Sevilla, Spain, 2017. 49. Wold, S.; Sjöström, M.; Eriksson, L. PLS-regression: A basic tool of chemometrics. In Chemometrics and Intelligent Laboratory Systems; Elsevier: Amsterdam, The Netherlands, 2001; Volume 58, pp. 109–130. 50. Kennard, R.W.; Stone, L.A. Computer Aided Design of Experiments. Technometrics 1969,11, 137–148. [CrossRef] 51. Picard, R.R.; Cook, R.D. Cross-validation of regression models. J. Am. Stat. Assoc. 1984,79, 575–583. [CrossRef] 52. Shenk, J.S.; Westerhaus, M. Calibration the ISI way. In Near Infrared Spectroscopy: The Future Waves; Davies, A.M.C., Williams, P.C., Eds.; NIR Publications: Chichester, UK, 1996; pp. 198–202. ISBN 978-0952866602.