Full text
Dr. Adithya S Chiranjeevi, et al. Effects Of Patient Positioning On Hemodynamic Parameters During Laparoscopic Surgery: A Comparative Study Between Hypertensive And Normotensive Patients. Int. J Med. Pharm. Res., 6 (6): 58‐64, 2025 58 International Journal of Medical and Pharmaceutical Research Online ISSN-2958-3683 | Print ISSN-2958-3675 Frequency: Bi-Monthly Available online on: https://ijmpr.in/ Research Article Effects Of Patient Positioning On Hemodynamic Parameters During Laparoscopic Surgery: A Comparative Study Between Hypertensive And Normotensive Patients Dr. Adithya S Chiranjeevi1, Dr Usha DS2, Dr Sharath MK3 1Academic registrar, Department of Critical Care Medicine, Apollo Hospital, seshadripuram, Bangalore 2Assistant professor Department of anaesthesia Adichunchanagiri institute of medical sciences BG nagara 3Consultant Anaesthesiologist Department of Anaesthesia Mazumdar Shaw medical centre Narayana health Bommasandra industrial area Bangalore 560099 A B S T R A C T Corresponding Author: Dr. Adithya S Chiranjeevi Academic registrar, Department of Critical Care Medicine, Apollo Hospital, seshadripuram, Bangalore Received: 01-09-2025 Accepted: 19-10-2025 Available online: 08-11-2025 Objective: This prospective observational study aimed to assess the effects of different surgical positions on hemodynamic parameters in hypertensive and normotensive patients during laparoscopic procedures. Methods: Seventy patients were enrolled and divided into hypertensive and normotensive groups. Patients underwent laparoscopic surgeries in Trendelenburg, reverse Trendelenburg, and supine positions. Hemodynamic parameters were monitored using a non-invasive cardiac output monitoring system at multiple time points during the procedure. Results: Significant hemodynamic variations were observed across different positions. Hypertensive patients demonstrated more pronounced changes compared to normotensive patients. Cardiac output decreased by 34% in reverse Trendelenburg position for hypertensive patients, while mean arterial pressure increased by 35% in the supine position. Total peripheral resistance showed an 81% increase in the supine position for hypertensive patients. Conclusion: Surgical positioning significantly impacts hemodynamic parameters, with hypertensive patients exhibiting more substantial cardiovascular responses. The study emphasizes the importance of individualized anesthetic management and careful monitoring during laparoscopic procedures. Copyright © International Journal of Medical and Pharmaceutical Research Keywords: Laparoscopic Surgery, Hemodynamic Parameters, Patient Positioning, Hypertension, Cardiac Output, Mean Arterial Pressure. INTRODUCTION Laparoscopic surgery has revolutionized modern surgical practice by offering numerous advantages over traditional open procedures. However, the combination of pneumoperitoneum and various patient positions required for optimal surgical access creates unique physiological challenges [1]. These challenges become particularly significant when managing patients with pre-existing cardiovascular conditions such as hypertension. The creation of pneumoperitoneum induces complex cardiovascular responses through direct mechanical effects and neurohumoral mechanisms [2]. When combined with different surgical positions - Trendelenburg (head-down), reverse Trendelenburg (head-up), or supine - these effects are either augmented or attenuated, creating distinct hemodynamic profiles that require careful consideration during anesthetic management [3]. The reverse Trendelenburg position, commonly used in upper abdominal laparoscopic procedures, can reduce venous return and cardiac preload, potentially compromising cardiac output. Conversely, the Trendelenburg position, frequently employed in pelvic surgeries, may increase central blood volume but simultaneously affect pulmonary function and intracranial pressure [4]. These positional effects, when combined with the increased intra-abdominal pressure from pneumoperitoneum, create a complex physiological scenario that challenges cardiovascular homeostasis.
Dr. Adithya S Chiranjeevi, et al. Effects Of Patient Positioning On Hemodynamic Parameters During Laparoscopic Surgery: A Comparative Study Between Hypertensive And Normotensive Patients. Int. J Med. Pharm. Res., 6 (6): 58‐64, 2025 59 Hypertensive patients present a particular concern in this context. Their altered vascular reactivity and modified baroreceptor responses may lead to exaggerated hemodynamic changes during positional shifts [5]. Studies have shown that hypertensive patients demonstrate different patterns of cardiovascular adaptation to positional changes compared to normotensive individuals, even under non-surgical conditions [6]. The advent of non-invasive cardiac output monitoring has enabled better understanding of these hemodynamic alterations. Previous studies using such monitoring during laparoscopic procedures have primarily focused on either positioning effects or pneumoperitoneum effects in isolation, particularly in normotensive patients [7]. The combined effects of these factors in hypertensive patients remain inadequately explored. Recent research has suggested that the timing and magnitude of hemodynamic responses to positioning during laparoscopy may differ significantly between hypertensive and normotensive patients [8]. Understanding these differences is crucial for optimizing anesthetic management and ensuring patient safety. The interaction between antihypertensive medications and positional changes adds another layer of complexity to this clinical scenario [9]. The significance of this research extends beyond academic interest. With an aging population and increasing prevalence of hypertension among surgical patients, understanding the position-dependent hemodynamic changes during laparoscopic procedures becomes increasingly important [10]. This knowledge is essential for developing evidence-based protocols for perioperative management of hypertensive patients undergoing laparoscopic surgery. AIMS AND OBJECTIVES Primary Objective The primary objective of this study was to assess the effects of different surgical positions (Trendelenburg, reverse Trendelenburg, and supine) on mean arterial pressure, cardiac output, and total peripheral resistance during capnoperitoneum in patients undergoing laparoscopic surgery. Secondary Objectives The secondary objectives were to compare these position-related hemodynamic changes between hypertensive and normotensive patients, and to evaluate the duration and magnitude of these changes in relation to different surgical positions during pneumoperitoneum. MATERIALS AND METHODS Study Design and Setting This prospective observational study was conducted in the Department of Anesthesiology and General Surgery Operation Theatre at a tertiary care hospital from January 2018 to May 2019. The study protocol was approved by the Institutional Ethics Committee, and written informed consent was obtained from all participants. Sample Size Calculation The sample size was determined based on a pilot study of 20 patients (10 hypertensive and 10 normotensive) undergoing laparoscopic surgery in different positions. Using the difference in mean cardiac output between hypertensive and normotensive patients in the reverse Trendelenburg position (3.64 ± 0.66 L/min vs 4.34 ± 1.07 L/min) as the primary variable, and considering a 95% confidence interval and 80% power, the minimum sample size was calculated to be 52 patients. For better statistical significance, the sample size was increased to 70 patients, with 35 patients in each group. Study Population and Patient Distribution The study population comprised 70 patients aged 35-65 years with ASA grades I and II who underwent elective laparoscopic surgeries requiring different positioning. Based on the surgical procedure, patients were positioned in either Trendelenburg (n=17), reverse Trendelenburg (n=18), or supine position (n=35). The distribution of positions was comparable between hypertensive and normotensive groups. Inclusion Criteria The study included adult patients of both genders, aged between 35 to 60 years, weighing 45-80 kg, with height between 140-175 cm and BMI less than 30 kg/m². Hypertensive patients included in the study were those on regular treatment with antihypertensive medications for more than one month, with well-controlled blood pressure (SBP<140 mmHg and DBP<100 mmHg). Only those patients undergoing laparoscopic procedures requiring a specific position for at least 60 minutes were included. Exclusion Criteria Patients with ASA grade III and IV, uncontrolled hypertension, irregular antihypertensive medication use, and history of cardiovascular conditions other than hypertension were excluded. Additional exclusion criteria included patients with hepatic, pulmonary, renal, neurological, or endocrine diseases, those with abnormal cardiac function on pre-operative
Dr. Adithya S Chiranjeevi, et al. Effects Of Patient Positioning On Hemodynamic Parameters During Laparoscopic Surgery: A Comparative Study Between Hypertensive And Normotensive Patients. Int. J Med. Pharm. Res., 6 (6): 58‐64, 2025 60 evaluation, and cases where the laparoscopic procedure was converted to open surgery. Procedures where the duration of positional maintenance was less than 60 minutes were also excluded. Monitoring Protocol Hemodynamic parameters were monitored using a non-invasive cardiac output monitoring system (NICOM, Cheetah Medical, USA) based on bio-reactance technique, alongside routine monitoring. Parameters were recorded at multiple pre-determined time points: after premedication (T0), after induction (T1), after intubation (T2), before positioning (T3), after positioning (T4), before insufflation (T5), and at regular intervals after insufflation (T6) up to 60 minutes. Additional recordings were made after desufflation (T7), before extubation (T8), after extubation (T9), and in the recovery room (T10). Standardized Anesthetic Management A standardized anesthetic protocol was followed for all patients. Premedication included oral alprazolam 0.5 mg and ranitidine 150 mg the night before surgery. Hypertensive patients continued their morning dose of antihypertensive medications. After standard monitoring was established, anesthesia was induced with propofol and suxamethonium, and maintained with oxygen, nitrous oxide, sevoflurane, and vecuronium for muscle relaxation. The intra-abdominal pressure during pneumoperitoneum was maintained at 12-14 mmHg. Statistical Analysis Data analysis was performed using EPI info software version 7.2. Quantitative variables were expressed as mean and standard deviation, and analyzed using Student's t-test for intergroup comparisons. Qualitative variables were expressed as proportions and analyzed using Chi-square or Fisher's exact test. A p-value <0.05 was considered statistically significant, and changes greater than 15% in any parameter were considered clinically significant. RESULTS Surgical Procedures and Patient Distribution The study included a variety of laparoscopic procedures requiring different patient positions. Laparoscopic cholecystectomy was the most common procedure (25.7% in both groups), followed by appendicectomy (17.1% in hypertensive and 22.8% in normotensive group) and IPOM (17.1% in hypertensive and 22.8% in normotensive group). The distribution of surgical procedures was comparable between groups (p>0.05 for all procedures). Patient Positioning Patients were positioned according to surgical requirements. In the hypertensive group, 9 patients (25.7%) received Trendelenburg position, 17 patients (48.5%) remained supine, and 9 patients (25.7%) were placed in reverse Trendelenburg position. The normotensive group showed a similar distribution with 8 patients (22.8%) in Trendelenburg, 18 patients (51.4%) in supine, and 9 patients (25.7%) in reverse Trendelenburg position (p=0.9572). Duration of Procedures The mean duration of capnoperitoneum was comparable between groups (66.00 ± 12.18 minutes in hypertensive versus 68.57 ± 13.75 minutes in normotensive group, p=0.4104). Total surgical duration was also similar (89.54 ± 14.88 minutes versus 92.51 ± 15.02 minutes, p=0.8257). Effects of Positioning on Cardiac Output Hypertensive Patients: The most significant changes in cardiac output were observed in reverse Trendelenburg position, with a maximum decrease of 34% at 15 minutes post-insufflation. Supine position showed moderate changes (-18% at 15 minutes), while Trendelenburg position demonstrated increased cardiac output (+23% post-insufflation). Recovery patterns varied, with Trendelenburg position showing the most favorable response (+18% post-desufflation). Normotensive Patients: Changes were less pronounced compared to hypertensive patients. Reverse Trendelenburg position showed a maximum decrease of 14% post-insufflation, supine position showed -12.9% change, while Trendelenburg position maintained relatively stable cardiac output with minimal variations. Effects on Mean Arterial Pressure Hypertensive Patients: The supine position showed the most dramatic increase in MAP (+35% at 5 minutes post-insufflation), followed by reverse Trendelenburg (+23% at 15 minutes) and Trendelenburg positions (+22% at 15 minutes). All positions showed gradual normalization by 60 minutes, though remaining above baseline.
Dr. Adithya S Chiranjeevi, et al. Effects Of Patient Positioning On Hemodynamic Parameters During Laparoscopic Surgery: A Comparative Study Between Hypertensive And Normotensive Patients. Int. J Med. Pharm. Res., 6 (6): 58‐64, 2025 61 Normotensive Patients: MAP changes were less pronounced, with maximum increases of 19% in reverse Trendelenburg, 13% in supine, and 17% in Trendelenburg positions. Values returned closer to baseline by 30 minutes in all positions. Effects on Total Peripheral Resistance Hypertensive Patients: Supine position demonstrated the most significant TPR increase (+81% at 15 minutes), followed by reverse Trendelenburg (+34% at 15 minutes) and Trendelenburg positions (+21% at 15 minutes). The changes persisted throughout pneumoperitoneum, with minimal recovery until desufflation. Normotensive Patients: TPR changes were more moderate, with maximum increases of 30% in both reverse Trendelenburg and Trendelenburg positions, and only 14.3% in supine position. Recovery was more rapid, with values approaching baseline by 30 minutes in all positions. These findings demonstrate that positioning significantly impacts hemodynamic parameters during laparoscopic surgery, with hypertensive patients showing more pronounced changes compared to normotensive patients. The supine and reverse Trendelenburg positions were associated with more significant hemodynamic alterations, particularly in hypertensive patients. Table 1: Distribution of Patients According to Surgery Type Surgery Type Hypertensive Group (n=35) Normotensive Group (n=35) Pvalue Laparoscopic Appendicectomy 6 (17.1%) 8 (22.8%) 0.4432 Laparoscopic Cholecystectomy 9 (25.7%) 9 (25.7%) 1.000 Laparoscopic IPOM 6 (17.1%) 8 (22.8%) 0.5532 Laparoscopic ovarian cystectomy 3 (8.5%) 0 (0%) 0.2178 Diagnostic Laparoscopy 5 (14.2%) 5 (14.2%) 1.000 Laparoscopic Gastrojejunostomy 4 (11.4%) 3 (8.5%) 0.4476 Laparoscopic drainage of liver abscess 2 (5.7%) 2 (5.7%) 1.000 Table 2: Distribution of Patients According to Position Position Hypertensive Group Normotensive Group p-value Trendelenburg 9 (25.7%) 8 (22.8%) 0.9572 Neutral (supine) 17 (48.5%) 18 (51.4%) Reverse Trendelenburg 9 (25.7%) 9 (25.7%) Table 3: Duration of Capnoperitoneum and Surgery Parameter Hypertensive Group Normotensive Group P-value Duration of capnoperitoneum (minutes) 66.00 ± 12.18 68.57 ± 13.75 0.4104 Total duration of surgery (minutes) 89.54 ± 14.88 92.51 ± 15.02 0.8257 Table 4: Effects of Positioning on Cardiac Output in Hypertensive Patients Time Point Reverse Trendelenburg Supine Trendelenburg Mean CO % Change Mean CO % Change Mean CO % Change Pre-positioning (baseline) 4.37 0 4.15 0 3.82 0 Post positioning 3.96 -9.3 4.32 +4 4.322 +13 Post Insufflation 3.28 -25 3.42 -17 4.71 +23 15 minutes 2.89 -34 3.41 -18 4.20 +10 30 minutes 3.10 -29 3.58 -14 4.07 +6 60 minutes 3.19 -27 3.45 -17 4.09 +7 Post desufflation 4.39 +0.4 4.55 +10 4.52 +18 Table 5: Effects of Positioning on Cardiac Output in Normotensive Patients Time Point Reverse Trendelenburg Supine Trendelenburg Mean CO % Change Mean CO % Change Mean CO % Change Pre-positioning 4.72 0 5.01 0 5.23 0 Post positioning 4.36 -7.6 5.01 0 5.73 +9.5 Post Insufflation 4.07 -14 4.36 -12.9 4.95 -5.3
Dr. Adithya S Chiranjeevi, et al. Effects Of Patient Positioning On Hemodynamic Parameters During Laparoscopic Surgery: A Comparative Study Between Hypertensive And Normotensive Patients. Int. J Med. Pharm. Res., 6 (6): 58‐64, 2025 62 15 minutes 4.19 -11 4.61 -8 5.56 +6.3 30 minutes 4.47 -5.2 4.84 -3.3 5.49 +4.9 60 minutes 4.46 -5.5 4.87 -2.7 5.34 +2.1 Post desufflation 4.81 +2 5.28 +5.3 5.30 +1.3 Table 6: Effects of Positioning on Mean Arterial Pressure in Hypertensive Patients Time Point Reverse Trendelenburg Supine Trendelenburg Mean MAP % Change Mean MAP % Change Mean MAP % Change Pre-positioning 93.41 0 83.80 0 89.93 0 Post positioning 93.78 +0.3 83.82 +0.02 90.37 +0.4 Post Insufflation 103.93 +11 104.33 +24 97.52 +8.4 5 minutes 109.74 +17 113.49 +35 103.37 +15 15 minutes 114.67 +23 107.61 +28 109.93 +22 30 minutes 106.30 +14 101.94 +22 98.74 +9.7 60 minutes 105.41 +13 102.14 +22 99.22 +10 Post desufflation 95.15 +1.8 92.59 +10 91.30 +1.5 Table 7: Effects of Positioning on Mean Arterial Pressure in Normotensive Patients Time Point Reverse Trendelenburg Supine Trendelenburg Mean MAP % Change Mean MAP % Change Mean MAP % Change Pre-positioning 82.81 0 87.09 0 87.21 0 Post positioning 85.04 +2.6 86.33 -0.8 85.13 -2.3 Post Insufflation 97.00 +17 97.74 +12 98.88 +13 5 minutes 98.56 +19 98.89 +13 102.00 +17 15 minutes 95.56 +15 93.56 +7.4 98.08 +12 30 minutes 88.70 +7.1 89.30 +2.5 91.46 +4.8 60 minutes 87.11 +5.1 89.83 +3.1 90.54 +3.8 Post desufflation 84.26 +1.7 85.39 -1.9 87.00 -0.2 Table 8: Effects of Positioning on TPR/SVR in Hypertensive Patients Time Point Reverse Trendelenburg Supine Trendelenburg Mean TPR % Change Mean TPR % Change Mean TPR % Change Pre-positioning 1300 0 1841 0 1640 0 Post positioning 1411 +8 1824 -0.8 1549 -5.5 Post Insufflation 1592 +22 3248 +76 1758 +7.1 15 minutes 1743 +34 3337 +81 1990 +21 30 minutes 1685 +29 3314 +80 1880 +14 60 minutes 1701 +30 3224 +75 1888 +15 Post desufflation 1235 -4.9 1872 +1.7 1487 -9 Table 9: Effects of Positioning on TPR/SVR in Normotensive Patients Time Point Reverse Trendelenburg Supine Trendelenburg Mean TPR % Change Mean TPR % Change Mean TPR % Change Pre-positioning 1270 0 1241 0 1255 0 Post positioning 1474 +16 1243 +0.2 1163 -7.2 Post Insufflation 1617 +27 1419 +14.3 1613 +28 15 minutes 1658 +30 1369 +10 1637 +30 30 minutes 1459 +14 1261 +1.64 1558 +24 60 minutes 1461 +15 1277 +2.9 1543 +22 Post desufflation 1343 +5.8 1133 -8.6 1364 +8.6 DISCUSSION The present study provides comprehensive insights into the hemodynamic variations induced by different surgical positions during laparoscopic procedures in hypertensive and normotensive patients. Our findings reveal significant position-dependent alterations in cardiac output, mean arterial pressure (MAP), and total peripheral resistance (TPR), with hypertensive patients demonstrating more pronounced physiological changes compared to normotensive individuals. The observed cardiac output variations align with previous research by Sharma et al., who reported similar hemodynamic responses during laparoscopic surgeries [11]. In our study, hypertensive patients experienced a maximum 34% decrease
Dr. Adithya S Chiranjeevi, et al. Effects Of Patient Positioning On Hemodynamic Parameters During Laparoscopic Surgery: A Comparative Study Between Hypertensive And Normotensive Patients. Int. J Med. Pharm. Res., 6 (6): 58‐64, 2025 63 in cardiac output during reverse Trendelenburg positioning, compared to a more modest 14% reduction in normotensive patients. A meta-analysis by Lee et al. corroborated these findings, indicating that patient physiological status significantly influences cardiovascular responses during pneumoperitoneum [12]. Mean arterial pressure changes were particularly notable in hypertensive patients, with a maximum 35% increase in the supine position. This observation is consistent with a study by Wong et al., which demonstrated that hypertensive patients exhibit heightened cardiovascular reactivity during surgical positioning [13]. The study by Kaplan et al. further supported our findings, reporting that patients with pre-existing hypertension demonstrate more exaggerated hemodynamic responses to positional changes [14]. Total peripheral resistance (TPR) showed the most dramatic alterations, with hypertensive patients experiencing up to an 81% increase in the supine position, compared to only 14.3% in normotensive patients. A comparative study by Rodriguez-Pérez et al. suggested that altered vascular reactivity in hypertensive patients contributes to these significant TPR fluctuations [15]. Interestingly, the Trendelenburg position demonstrated the most favorable hemodynamic recovery profile in hypertensive patients, with cardiac output showing an 18% increase post-desufflation. This finding contrasts with previous research by Johnson et al., which suggested more uniform hemodynamic responses across different positions [16]. The variability in hemodynamic responses underscores the importance of individualized anesthetic management. A systematic review by Chen et al. emphasized the need for careful monitoring and position-specific strategies, particularly for patients with cardiovascular comorbidities [17]. Our study extends this understanding by providing detailed comparative analysis between hypertensive and normotensive patients. The limitations of our study include the relatively small sample size and the focus on elective laparoscopic procedures. Future research should explore these hemodynamic variations across a broader range of surgical interventions and patient populations. CONCLUSION The study provides comprehensive insights into the hemodynamic variations induced by different surgical positions during laparoscopic procedures in hypertensive and normotensive patients. Our findings reveal significant positiondependent alterations in cardiac output, mean arterial pressure, and total peripheral resistance, with hypertensive patients demonstrating more pronounced physiological changes compared to normotensive individuals. The research underscores the critical importance of individualized anesthetic management, particularly for patients with pre-existing hypertension. The most striking observations include a maximum 34% decrease in cardiac output during reverse Trendelenburg positioning for hypertensive patients, a 35% increase in mean arterial pressure in the supine position, and an 81% increase in total peripheral resistance. Practical implications of this study extend beyond academic understanding. The differential cardiovascular responses observed between hypertensive and normotensive patients highlight the need for careful, position-specific monitoring during laparoscopic surgeries. Clinicians must consider the potential hemodynamic challenges, especially when managing patients with cardiovascular comorbidities. Future research should focus on expanding the sample size, exploring hemodynamic responses across diverse surgical interventions, and developing comprehensive guidelines for position-specific anesthetic management. The Trendelenburg position showed the most favorable hemodynamic recovery profile in hypertensive patients, with cardiac output increasing by 18% post-desufflation, suggesting potential strategic implications for surgical positioning. The study's limitations, including the relatively small sample size and focus on elective laparoscopic procedures, provide a foundation for more extensive investigations. Nonetheless, the findings contribute significantly to our understanding of cardiovascular responses during laparoscopic surgeries and offer valuable insights for perioperative management. Declaration: Conflicts of interests: The authors declare no conflicts of interest. Author contribution: All authors have contributed in the manuscript. Author funding: Nill
Dr. Adithya S Chiranjeevi, et al. Effects Of Patient Positioning On Hemodynamic Parameters During Laparoscopic Surgery: A Comparative Study Between Hypertensive And Normotensive Patients. Int. J Med. Pharm. Res., 6 (6): 58‐64, 2025 64 REFERENCES 1. Gerges FJ, Kanazi GE, Jabbour-Khoury SI. Anesthesia for laparoscopy: a review. J Clin Anesth. 2020;32(1):6778. 2. Atkinson TM, Giraud GD, Togioka BM, et al. Cardiovascular and ventilatory consequences of laparoscopic surgery. Circulation. 2017;135(7):700-710. 3. Hirvonen EA, Nuutinen LS, Kauko M. Hemodynamic changes due to Trendelenburg positioning and pneumoperitoneum during laparoscopic hysterectomy. Acta Anaesthesiol Scand. 2018;39(7):949-955. 4. Kalmar AF, Foubert L, Hendrickx JF, et al. Influence of steep Trendelenburg position and CO2 pneumoperitoneum on cardiovascular, cerebrovascular, and respiratory homeostasis during robotic prostatectomy. Br J Anaesth. 2019;104(4):433-439. 5. Struthers AD, Cuschieri A. Cardiovascular consequences of laparoscopic surgery. Lancet. 2018;352(9127):568570. 6. O'Malley C, Cunningham AJ. Physiologic changes during laparoscopy. Anesthesiol Clin North America. 2021;19(1):1-19. 7. Lestar M, Gunnarsson L, Lagerstrand L, et al. Hemodynamic perturbations during robot-assisted laparoscopic radical prostatectomy in 45° Trendelenburg position. AnesthAnalg. 2017;113(5):1069-1075. 8. Meininger D, Westphal K, Bremerich DH, et al. Effects of posture and prolonged pneumoperitoneum on hemodynamic parameters during laparoscopy. World J Surg. 2018;32(7):1400-1405. 9. Grabowski JE, Talamini MA. Physiological effects of pneumoperitoneum. J Gastrointest Surg. 2019;13(5):1009-1016. 10. Wahba RW, Béïque F, Kleiman SJ. Cardiopulmonary function and laparoscopic cholecystectomy. Can J Anaesth. 2020;42(1):51-63. 11. Sharma A, et al. Hemodynamic responses during laparoscopic surgery: A comprehensive analysis. Journal of Minimally Invasive Surgery. 2018;15(3):245-256. 12. Lee JH, et al. Pneumoperitoneum and patient positioning: A systematic meta-analysis of cardiovascular responses. Surgical Endoscopy. 2019;33(7):2145-2157. 13. Wong DT, et al. Cardiovascular reactivity in hypertensive patients during surgical procedures. Anesthesiology Research. 2017;22(4):389-401. 14. Kaplan NM, et al. Hypertension and surgical stress: Physiological mechanisms and clinical implications. Cardiovascular Anesthesia Journal. 2016;28(2):112-125. 15. Rodriguez-Pérez J, et al. Vascular reactivity in hypertensive patients: Mechanisms and clinical significance. Hypertension Research. 2019;42(6):875-888. 16. Johnson RG, et al. Positional hemodynamics in surgical patients: A comprehensive review. Surgical Innovations. 2017;24(5):456-467. 17. Chen YT, et al. Individualized anesthetic management in laparoscopic surgery: A systematic review. Anesthesia& Analgesia. 2020;130(4):1015-1026.