Impact of the Guard Rings on Self-Induced Signal and Leakage Current in Trench-Isolated Low Gain Avalanche Diodes

Lastovicka-Medin, Gordana; Kramberger, Gregor; Kroll, Jiri; Rebarz, Mateusz

Abstract

In this contribution, we explored the interplay of guard ring (GR) configurationand isolation structures, as well as irradiation effects, which all together create a richlandscape of phenomena such as self-induced signals (“ghosts”) in trench-isolated LowGain Avalanche Diodes (TI-LGADs). The ghost effect is related to the increased surface current due to presence of SiO2 trenches (and defects) in studied diodes, but it is also affected by interplay between the guard ring(s) and the n+ bias ring, implanted in interpixel region of these devices. In double-trenched sensors, the n+ bias ring is inserted in between the two trenches. We present the investigation on the role of these structures on the self-induced signals in trench-isolated sensors from two different productions (RD50 and AIDAinnova). The sensors from the first production have multiple guard rings, whereas the second type of devices feature only one. Detailed examination of the ghost effect and leak current was performed when guard rings were left floating or connected to the pixels (brought to the same potential). The results show that guard ring configuration in trenched sensors can be critical for the leak current and the presence of a ghost signal. To our best knowledge, the latter problem has not been investigated yet

Full text

Academic Editors: Francesco Della Corte and Antonio Di Bartolomeo Received: 14 March 2025 Revised: 4 May 2025 Accepted: 8 May 2025 Published: 10 May 2025 Citation: Lastovicka-Medin, G.; Kramberger, G.; Kroll, J.; Rebarz, M. Impact of the Guard Rings on Self-Induced Signal and Leakage Current in Trench-Isolated Low Gain Avalanche Diodes. Sensors 2025,25, 3006. https://doi.org/10.3390/ s25103006 Copyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/ licenses/by/4.0/). Article Impact of the Guard Rings on Self-Induced Signal and Leakage Current in Trench-Isolated Low Gain Avalanche Diodes Gordana Lastovicka-Medin 1,* , Gregor Kramberger 2, Jiri Kroll 3and Mateusz Rebarz 4 1Faculty of Natural Sciences and Mathematics, University of Montenegro, Dzordza Vashingtona, 81000 Podgorica, Montenegro 2Jozef Stefan Institute, Jamova Cesta 39, 1000 Ljubljana, Slovenia; gregor.kramber[email protected] 3Institute of Physics, Academy of Sciences of the Czech Republic, Na Slovance 2, 18221 Prague, Czech Republic; [email protected] 4ELI Beamlines Facility, The Extreme Light Infrastructure ERIC, Za Radnicí 835, 25241 Dolní Bˇrežany, Czech Republic; [email protected] *Correspondence: gor[email protected] Abstract: In this contribution, we explored the interplay of guard ring (GR) configuration and isolation structures, as well as irradiation effects, which all together create a rich landscape of phenomena such as self-induced signals (“ghosts”) in trench-isolated LowGain Avalanche Diodes (TI-LGADs). The ghost effect is related to the increased surface current due to presence of SiO 2 trenches (and defects) in studied diodes, but it is also affected by interplay between the guard ring(s) and the n + bias ring, implanted in interpixel region of these devices. In double-trenched sensors, the n + bias ring is inserted in between the two trenches. We present the investigation on the role of these structures on the self-induced signals in trench-isolated sensors from two different productions (RD50 and AIDAinnova). The sensors from the first production have multiple guard rings, whereas the second type of devices feature only one. Detailed examination of the ghost effect and leak current was performed when guard rings were left floating or connected to the pixels (brought to the same potential). The results show that guard ring configuration in trenched sensors can be critical for the leak current and the presence of a ghost signal. To our best knowledge, the latter problem has not been investigated yet. Keywords: LGAD; inter-pixel region; trench isolation; self-induced signals; guard ring; bias ring; IV characteristics; TCT technique 1. Introduction A Low-Gain Avalanche Detector (LGAD) is an n-on-p diode (n ++ /p + /p/p ++ structure) with moderate internal gain enabled by a thin (~2 µ m) highly doped p + layer inserted beneath the n ++ layer. These devices were designed as minimum ionizing particle time detectors (MIP TD) and high-granularity time detectors (HGDT) for Compact Muon Solenoid (CMS) and ATLAS experiments [ 1 ]. At the physical edge of the standard segmented LGAD, there are guard rings (GRs). These structures have the task of grading the voltage from the sensor edge to the first read-out pad, held at virtual ground by the read-out electronics. Each GR consists of an n ++ doped implant, equipped with metal field plates. A p + implant (either a p-stop or p-spray) is (in most designs) interposed between each pair of GRs, with the outer one left floating, and the inner one generally grounded in order to collect the leakage current generated outside the core region of the device. There are a few challenges in designing the periphery and interpad region in LGADs. Sensors 2025,25, 3006 https://doi.org/10.3390/s25103006 Sensors 2025,25, 3006 2 of 14 1. Junction Termination Extension (JTE): In standard LGADs, the gain layer is surrounded by a deep n ++ implant (JTE), which includes a metal field plate. The JTE is placed around each pad to prevent charge carriers generated in the interpad region from reaching the gain layer. When a particle traverses the gain layer, electrons immediately trigger the avalanche multiplication process. However, if charge carriers are generated in the interpad region, they must first drift to the gain implant, introducing a significant delay. The JTE mitigates this issue by confining the sensor’s active area to the regions where the gain implant is present. 2. P-stop isolation: In standard segmented LGADs, n ++ implants must be electrically isolated from one another. This can be achieved using an additional p ++ implant known as a p-stop. In some designs, isolation is enhanced by incorporating two pstops along with a central n + bias ring positioned between them. In order to improve the fill factor in segmented sensors, the isolation structures of small dimensions are desired. However, they lower sensor capability to hold high bias voltages. The pstop structure is floating, so it floats to a potential between that of the n ++ implant and the bias. There is, therefore, a strong electric field between the p-stop and the n ++ pad: the shorter this distance, the higher the field. A few interesting features have been observed: (i) larger interpad distances lead to higher breakdown voltages, and (ii) the design with the widest interpad distance exhibits a breakdown due to gain. The high value of the p-stop doping is detrimental to sensor stability due to the presence of positive charges in SiO 2 (at the Si-SiO 2 interface). In contrast, low doping values increase the capability of holding high bias voltages even with short interpad distances. However, too low values of the p-stop doping might not assure pad isolation [2]. 3. Guard rings: The role of GRs becomes increasingly complex as sensor thickness decreases. In ultrafast sensors, the lateral expansion of the depletion region is approximately equal to the sensor thickness. Consequently, floating GRs must be positioned within a lateral distance of about 2–3 times the active thickness from the innermost GR. Reducing the lateral spread of GRs increases the electric field between them, which can lead to premature breakdown. This poses a significant challenge in the design of ultrathin (~20–30 µ m) ultrafast sensors. Even the innermost GR can be left floating, but in such a configuration, the adjacent pads will exhibit higher leakage current. The p-stops between GRs float to a potential between the bias voltage and ground; given the much-reduced thickness of the bulk, the p-stop in this case might float to potential quite close to the bias value. Under this condition, the sequence of GRs might not be able to sustain a large voltage drop. In RD50 TI-LGADs multiple GRs designs were applied (Figure 1a). In the standard version, the innermost ring is thicker than the others and can be contacted through an opening in the passivation. The rings should be isolated from each other; however, this depends on the depletion of the sensor. 4. GR optimization: The optimization of the sensor’s periphery is crucial to enable the sensor (if very thin ( ≤ 4 µ m) or with a very narrow (few µ m) interpad region) to operate efficiently up to very high fluence (~1 × 10 17 1 MeV n eq /cm 2 ). If the peripheral region is too short, the depletion region can eventually reach the chip edge, leading to a high current injection into the core region. Devices with shorter trenches are even more vulnerable to this problem. When designing GR layout, while at the same time we are reaching sensor’s limits (geometric and operational) some sensor’s parameters may counteract and cancel each other. For instance, the optimization of the guard ring (GR) protection structure, especially when small substrate thicknesses are used, was extensively and systematically studied in a recent R&D batch produced at Fondazione Bruno Kessler (FBK) in the framework of the “eXFlu” project—INFN CSN5 grant Sensors 2025,25, 3006 3 of 14 for Young Researchers, where different optimization studies of GR structures for thin substrates (45, 30, 20 and 15 µ m) up to high fluence ( 2.5 ×1015 1 MeV neq/cm2 ) were conducted [ 3 , 4 ]. Those studies have been enabled thanks to advanced Technology CAD (TCAD) modelling of different GR design strategies, accounting for the comprehensive bulk and surface radiation-induced damage effects. Typically, the sensor’s periphery region is (as already mention) composed by a collector ring, i.e., the bias ring, and a floating guard ring where GR ring is devised with both n-deep and p-stop implant. P-stop cuts off the possible buildup of the “inversion layer”, i.e., a surface leakage current path between the collector ring and the n-deep implant itself, thus avoiding connection between them. One of the most important massages and outcomes from the extensive study on GR structure layouts (on the samples from the eXFlu1 batch) was that after a fluence of 1 × 10 16 n eq /cm 2 , a sensor periphery with floating GR seems to be more effective without any p-stop implant, benefiting from the concurrent action of bulk and surface damage to mitigate the build-up of the inversion layer. This result was very useful for the FBK decision on GR structure design implemented in the second TI-LGAD production (AIDAinnova batch). In the second TI-LGAD production (AIDAinnova batch), it was decided not to use the multi-GRlayout with multi-floating GRs anymore, but instead to use a single GR layout (shown in Figure 1b). The prevention of injection of surface leakage current in the core region of the sensor if the periphery region is too short [5] is still challenging task. 5. Trench Isolation: In 2019 the feasibility of implementing thin LGADs segmented using the SiO 2 trench isolation technology was demonstrated and the first TI-LGAD batch was fabricated at Fondazione Bruno Kessler (FBK) within the RD50 Common project [ 6 , 7 ]. The wafer layout consists of pairs of pads (Figure 1a) with pad size 375 × 250 µ m 2 , fabricated on 55 and 45 µ m-thick p-epitaxial bulk. The layout splits implemented about 30 pairs, differing in the number of trenches (1 or 2), the dimension of the borders, trench process parameters, depth of trench (D1 < D2 < D3), and the distance between pixel borders (V1 < V2 < V3). Two different trench designs have been implemented in the first TI-LGADs production. The first one has a trench grid between pads (1TR), while in the second one, each pad is surrounded by an independent pair of trench rings (2TR). The nominal distance between the gain implants in the 1TR and 2TR designs is ~4 µ m and ~6 µ m [ 8 ], respectively. The second TI-LGAD production was released 2 years later, within the AIDAinnova project (Figure 1b) [ 9 ], also at FBK. In this production a medium depth of trench (equivalent of D2 in RD50 production) was chosen as standard while the width of trenches was varied. This production was also the first where carbon was implemented to increase the radiation hardness. In our previous studies on TI-LGADs from both RD50 and AIDAinnova productions [ 10 – 12 ], we observed the extraordinary self-induced (without external stimulation) pulse signal, that we call “ghost”, appearing in all TI-LGADs after exceeding a certain value of applied bias. The example of a ghost signal with comparison to a standard signal generated in the same LGAD sensor is shown in Figure 1d. The properties of these signals, such as amplitude, duration, and occurrence rate, depend on many factors. Trench configuration (1TR or 2TR), temperature, and irradiation affect the ghosts’ characteristics. The observed phenomenon is a complex interplay of many parameters where the manufacturing and process parameters for the studied sensors are not publicly accessible (due to non-disclosure agreements with vendor FBK). For this reason, performing simulations that would reliably support ghost effect elucidations is not yet possible. The current understanding of the discussed phenomena is fully based on the experimental observations, and a summary of the key results is presented in Section 3.1.1. Extending the previous research, here we investigate and discuss the influence of the GR configuration Sensors 2025,25, 3006 4 of 14 on the ghost signal in TI-LGADs. Sensors with multiple GRs (RD50) and a single GR (AIDAinnova) were investigated for this purpose. In addition, the impact of floating or biasing (connecting to pad) of the GRs on ghost effect is examined, and related changes in leakage current are discussed. Sensors 2025, 25, x FOR PEER REVIEW 4 of 15 Figure 1. Layout of 1 × 2 pixels array of TI-LGADs: (a) RD50 sensor with multiple guard rings. (b) AIDAinnova sensor with single guard ring. (c) Cross-section of LGAD sensor with single trench. (d) Comparison of self-induced ghost signal in TI-LGAD device at 100 V with normal signal generated in pad of this sensor by 5 pJ laser pulse at the same bias. Trench configuration (1TR or 2TR), temperature, and irradiation affect the ghosts’ characteristics. The observed phenomenon is a complex interplay of many parameters where the manufacturing and process parameters for the studied sensors are not publicly accessible (due to non-disclosure agreements with vendor FBK). For this reason, performing simulations that would reliably support ghost effect elucidations is not yet possible. The current understanding of the discussed phenomena is fully based on the experimental observations, and a summary of the key results is presented in Section 3.1.1. Extending the previous research, here we investigate and discuss the influence of the GR configuration on the ghost signal in TI-LGADs. Sensors with multiple GRs (RD50) and a single GR (AIDAinnova) were investigated for this purpose. In addition, the impact of floating or biasing (connecting to pad) of the GRs on ghost effect is examined, and related changes in leakage current are discussed. 2. Materials and Methods The sensors used in this study were designed and manufactured by Fondazione Bruno Kessler (FBK, Trento, Italy) within two different productions: RD50 and AIDAinnova. Every sensor had a form of 2 × 1 array (two pixels isolated by SiO2 trenches), as shown in Figure 1. Selected sensors were irradiated with neutrons at the Triga II Reactor of the Jozef Stefan Institute (JSI) in Ljubljana, Slovenia. A full list of the sensors examined in this study is presented in Table 1. The self-induced (ghost) signal generated upon the applied voltage was investigated by transient current technique (TCT) using the experimental setup at the ELI Beamlines facility (Dolni Brezany, Czech Republic) [13]. The aluminum housings, fabricated and designed at the Jozef Stefan Institute, were used for the samples mounting. The image of example housing is shown in Figure 2a. The samples were conductively connected to the housing itself (this all is then connected to the ground) and biasing of the sensors was achieved from the top side. Both signal pads of the sample were wire bonded to the pin of Figure 1. Layout of 1 × 2 pixels array of TI-LGADs: (a) RD50 sensor with multiple guard rings. (b) AIDAinnova sensor with single guard ring. (c) Cross-section of LGAD sensor with single trench. (d) Comparison of self-induced ghost signal in TI-LGAD device at 100 V with normal signal generated in pad of this sensor by 5 pJ laser pulse at the same bias. 2. Materials and Methods The sensors used in this study were designed and manufactured by Fondazione Bruno Kessler (FBK, Trento, Italy) within two different productions: RD50 and AIDAinnova. Every sensor had a form of 2 × 1 array (two pixels isolated by SiO 2 trenches), as shown in Figure 1. Selected sensors were irradiated with neutrons at the Triga II Reactor of the Jozef Stefan Institute (JSI) in Ljubljana, Slovenia. A full list of the sensors examined in this study is presented in Table 1. The self-induced (ghost) signal generated upon the applied voltage was investigated by transient current technique (TCT) using the experimental setup at the ELI Beamlines facility (Dolni Brezany, Czech Republic) [ 13 ]. The aluminum housings, fabricated and designed at the Jozef Stefan Institute, were used for the samples mounting. The image of example housing is shown in Figure 2a. The samples were conductively connected to the housing itself (this all is then connected to the ground) and biasing of the sensors was achieved from the top side. Both signal pads of the sample were wire bonded to the pin of the SMA connector (which is electrically isolated from aluminum housing) as depicted in Figure 2b. The pin was connected to HV power supply (EBS C0_30SHV, ISEG Spezialelektronik, Radberg, Germany) via a bias tee and the signal output was coupled directly to the oscilloscope (InfiniiVision DSOX6004A, 6 GHz, 20 GS, Keysight, Santa Rosa, CA, USA) without additional amplifiers. The generated waveforms were recorded at different bias up to maximal non-destructive values for a given sensor. The occurrence rate of the ghost signal was also measured by integrated counter with totalizer function (maximal measurable rate Sensors 2025,25, 3006 5 of 14 25 MHz). The housings with sensors were placed on the cooling plate and all measurements were conducted at room (+20 ◦C) and low (−20 ◦C) temperature. Table 1. Trench-isolated sensors used in this study. Production Sensor Wafer Type Irradiation RD50 LGAD W11 C1-V2-2TR No PIN W11 C1-V4-2TR No LGAD W3 C1-V2-2TR 0.8 ×1015 neq/cm2 PIN W3 C1-V2-2TR 0.8 ×1015 neq/cm2 AIDAinnova LGAD W1 V2-2TR TW5 Cell-D TS1 No PIN W1 1TR TW5 Cell-D TS1 No LGAD W1 V2-1TR TW5 Cell-C TS3 0.8 ×1015 neq/cm2 PIN W1 1TR TW2 Cell-C TS3 0.8 ×1015 neq/cm2 LGAD W1 V3-1TR TW5 Cell-C TS8 1.5 ×1015 neq/cm2 PIN W1 1TR TW6 Cell-C TS4 1.5 ×1015 neq/cm2 Sensors 2025, 25, x FOR PEER REVIEW 5 of 15 the SMA connector (which is electrically isolated from aluminum housing) as depicted in Figure 2b. Table 1. Trench-isolated sensors used in this study. Production Sensor Wafer Type Irradiation RD50 LGAD W11 C1-V2-2TR No PIN W11 C1-V4-2TR No LGAD W3 C1-V2-2TR 0.8 × 1015 neq/cm2 PIN W3 C1-V2-2TR 0.8 × 1015 neq/cm2 AIDAinnova LGAD W1 V2-2TR TW5 Cell-D TS1 No PIN W1 1TR TW5 Cell-D TS1 No LGAD W1 V2-1TR TW5 Cell-C TS3 0.8 × 1015 neq/cm2 PIN W1 1TR TW2 Cell-C TS3 0.8 × 1015 neq/cm2 LGAD W1 V3-1TR TW5 Cell-C TS8 1.5 × 1015 neq/cm2 PIN W1 1TR TW6 Cell-C TS4 1.5 × 1015 neq/cm2 The pin was connected to HV power supply (EBS C0_30SHV, ISEG Spezialelektronik, Radberg, Germany) via a bias tee and the signal output was coupled directly to the oscilloscope (InfiniiVision DSOX6004A, 6 GHz, 20 GS, Keysight, Santa Rosa, CA, USA) without additional amplifiers. The generated waveforms were recorded at different bias up to maximal non-destructive values for a given sensor. The occurrence rate of the ghost signal was also measured by integrated counter with totalizer function (maximal measurable rate 25 MHz). The housings with sensors were placed on the cooling plate and all measurements were conducted at room (+20 °C) and low (−20 °C) temperature. Figure 2. (a) Aluminum housing used for sensors mounting; (b) example 1 × 2 pixel sensor with indicated wire bonds; (c) AIDAinnova and (d) RD50 sensors during IV measurements. Figure 2. (a) Aluminum housing used for sensors mounting; (b) example 1 × 2 pixel sensor with indicated wire bonds; (c) AIDAinnova and (d) RD50 sensors during IV measurements. I–V measurements were performed in the Institute of Physics at Czech Academy of Science (Prague, Czech Republic) using an automatic probe station (TESLA200, FormFactor) with the triaxial chuck enclosed in the environmental chamber. The chuck with a golden surface (diameter of 200 mm) and implemented vacuum circuits was connected by the HV compatible triaxial cable with the HI of the source measure unit (SMU) via the 1 M Ω protection resistor. The testing pad and GR were contacted by the probes (see Figure 2c,d), which were entering the probe station environmental chamber through the so-called top hat. The probe contacting the testing pad was brought to the SMU LO by the triaxial cable. Sensors 2025,25, 3006 6 of 14 The GR of the sample was brought to the laboratory ground by the second probe, again by the triaxial cable. During the measurement, the relative humidity in the environmental chamber of the probe station was decreased to close to zero values. All TCT and I–V measurements were performed for two different configurations of guard rings connections. In the first variant, all GRs in the sensors were left floating. In the second case, the innermost ring was brought to the pad potential by wire bonding of the corresponding areas (see Figure 2b). 3. Results 3.1. Ghosts in Trench-Isolated Sensors with Floating Guard Rings 3.1.1. Previous Results The occurrence of self-induced signals is a complex phenomenon involving various factors so we first provide a short summary of our previous results. We observed the first ghosts in the non-irradiated LGAD originated from RD50 production with double-trench IP isolation. In the next steps, we investigated the role of the following factors [10–12]: •presence of the gain layer (LGAD vs. PIN) •number of trenches (2TR vs. 1TR) •irradiation effects (gain loss) •temperature effects (room temperature vs. low temperature) •gain layer carbonization (RD50 vs. AIDAinnova) All these studies revealed that different types of ghosts exist in trench-isolated sensors depending on the sensor type and experimental conditions. Three main types of ghosts were identified. • Type A: Signal appearing at low bias (typically 30–100 V in non-irradiated sensors) with occurrence rate decreasing with increasing bias (atypical features for auto-triggered signals in devices with internal gain and charge multiplication). This signal is strictly related to the presence of the gain layer. It is not observed in PINs (no gain) or irradiated LGADs that lost their gain (RD50 LGADs). We assumed that onset of this type of ghosts is around the GR structures. These discharges, experimentally verified and presented in [ 13 ], are enhanced by irradiation but significantly suppressed at low temperatures (tied to thermally activated processes, such as carrier generation via shallow traps or surface states). • Type B: Signal appearing in medium bias range (typically >80 V in non-irradiated sensors) exclusively in 2TR LGADs. The signal of the same characteristics (amplitude and shape) can be also generated by laser stimulation when inter-pixel region is illuminated. This type of signal comes from the defects created between the trenches that can be thermally populated at room temperature (this signal is strongly suppressed at low temperature). Moderate dependence of its occurrence rate on bias is attributed to the presence of n+implant placed between the trenches. • Type C: Signal appearing at high bias (typically >200 V) exhibiting strong amplitude (order of magnitude higher than others). Occurrence rate of these events is strongly bias dependent and increases with rising voltage. This type of signal is associated with high-field phenomena such as impact ionization, avalanche processes, or enhanced trap-assisted carrier generation under strong electric fields. It is observed in all types of TI sensors when high enough bias value is reached. The existence of individual types of ghost signals in different trench-isolated sensors is summarized in Table 2. In the following subsections, the new results for the sensors with different GRs configurations are presented. Sensors 2025,25, 3006 7 of 14 Table 2. Occurrence of different types of ghost signals in different trench-isolated sensors. Sensor RD50 Production (Multiple GRs, Non-Carbonized) AIDAinnova Production (Single GR, Carbonized) Non-Irradiated Irradiated Non-Irradiated Irradiated LGAD 1TR Type C Type A, C no exp. data Type A, C 2TR Type A, B, C Type C Type A, B, C Type A, B, C PIN 1TR no ghosts Type C no ghosts Type C 2TR no ghosts Type C no ghosts no exp. data 3.1.2. RD50 Sensors with Multiple GRs In case of LGADs from RD50 production, the ghosts appeared when the bias reached different level (depending on the sensor) in the range 30–90 V. These self-induced discharges are represented by the waveforms with width of several nanoseconds and amplitudes in the range of hundredths of mVs (see Figure 3a). Above the generation threshold, the ghosts are present in entire bias range, up to maximal non-destructive values (typically between 160 and 220 V, depending on the sensor and temperature). The ghost signal in this range vanishes completely in irradiated sensors. However, very strong self-induced discharges occur when the bias reaches the values close to the breakdown limits. In case of the sensors irradiated to fluence of 0.8 × 10 15 n eq /cm 2 , where the breakdown bias is typically in the range 500–550 V, the ghosts appear at the voltage above 450 V. In comparison to their counterparts in non-irradiated samples, the representative waveforms have much higher amplitude (up to 4 V), multipeak shape and they are much broader extending up to 40–45 ns (see Figure 3a). The very similar signal was also observed in corresponding PIN irradiated at the same fluence (compare with Figure 3b). It is noteworthy that in non-irradiated PINs the ghosts were not observed even at the highest applicable bias and their presence in LGADs was attributed to the gain layer. However, in irradiated PIN, the self-induced signal is observed at the bias above 450 V in spite of lack of gain. Similarly to the irradiated LGADs, the ghosts appear at bias voltages very close to the onset of radiation-induced breakdown in the bulk. The multipeak character of this signal either in PIN or LGAD can be attributed to the presence of multiple GRs in all RD50 sensors (see Section 4below). Sensors 2025, 25, x FOR PEER REVIEW 7 of 15 with high-field phenomena such as impact ionization, avalanche processes, or enhanced trap-assisted carrier generation under strong electric fields. It is observed in all types of TI sensors when high enough bias value is reached. The existence of individual types of ghost signals in different trench-isolated sensors is summarized in Table 2. In the following subsections, the new results for the sensors with different GRs configurations are presented. Table 2. Occurrence of different types of ghost signals in different trench-isolated sensors. Sensor RD50 Production (Multiple GRs, Non-Carbonized) AIDAinnova Production (Single GR, Carbonized) Non-Irradiated Irradiated Non-Irradiated Irradiated LGAD 1TR Type C Type A,C no exp. data Type A, C 2TR Type A, B, C Type C Type A, B,C Type A, B, C PIN 1TR no ghosts Type C no ghosts Type C 2TR no ghosts Type C no ghosts no exp. data 3.1.2. RD50 Sensors with Multiple GRs In case of LGADs from RD50 production, the ghosts appeared when the bias reached different level (depending on the sensor) in the range 30–90 V. These self-induced discharges are represented by the waveforms with width of several nanoseconds and amplitudes in the range of hundredths of mVs (see Figure 3a). Above the generation threshold, the ghosts are present in entire bias range, up to maximal non-destructive values (typically between 160 and 220 V, depending on the sensor and temperature). The ghost signal in this range vanishes completely in irradiated sensors. However, very strong self-induced discharges occur when the bias reaches the values close to the breakdown limits. In case of the sensors irradiated to fluence of 0.8 × 1015 neq/cm2, where the breakdown bias is typically in the range 500–550 V, the ghosts appear at the voltage above 450 V. In comparison to their counterparts in non-irradiated samples, the representative waveforms have much higher amplitude (up to 4 V), multipeak shape and they are much broader extending up to 40–45 ns (see Figure 3a). The very similar signal was also observed in corresponding PIN irradiated at the same fluence (compare with Figure 3b). It is noteworthy that in non-irradiated PINs the ghosts were not observed even at the highest applicable bias and their presence in LGADs was aributed to the gain layer. However, in irradiated PIN, the self-induced signal is observed at the bias above 450 V in spite of lack of gain. Similarly to the irradiated LGADs, the ghosts appear at bias voltages very close to the onset of radiation-induced breakdown in the bulk. The multipeak character of this signal either in PIN or LGAD can be aributed to the presence of multiple GRs in all RD50 sensors (see Section 4 below). Figure 3. Ghost signals in irradiated and non-irradiated (a) LGADs (W11 C1-V2-2TR) and (b) PIN (W11 C1-V4-2TR) from RD50 production. 3.1.3. AIDAinnova Sensors with Single GR In the trench-isolated sensors from the AIDAinnova production, two important aspects make them different from RD50 samples. LGADs from this production have a gain layer Sensors 2025,25, 3006 8 of 14 enriched with carbon. In addition, all AIDAinnova sensors feature only a single guard ring, contrary to the multiple GR structure in RD50 samples. These alterations can lead to different ghosts’ behavior. In non-irradiated TI-LGADs from AIDAinnova production, self-induced signal is quite similar to that observed in RD50. It appears above 30 V and increases with bias up to 90 V. Above that value, the signal changes its character, becoming broader and featuring lower amplitude. These signals, assigned before as Type A and Type B (see Section 3.1.1), are shown in Figure 4a. In the corresponding non-irradiated PIN sensor, the ghosts were not observed. After irradiation, the additional type of ghost, present at high bias values, appears in TI-LGAD but also in TI-PIN [ 11 ]. Although this signal exhibits very high amplitude (up to 2 V), it is very different from its counterpart recorded in RD50 irradiated sensors. The waveform is very narrow (see Figure 4b) and does not display the multipeak character. This feature is assigned to the fact that only a single guard ring is present in the sensors from AIDAinnova production. Although the difference between the two discussed productions lays not only in GRs configuration but also in gain carbonization (to reduce losses due to irradiation), the observed difference in ghost waveforms is manifested not only in LGADs but also in PINs without gain layer. Hence, the observed effect is only attributed to the difference in GRs. Sensors 2025, 25, x FOR PEER REVIEW 8 of 15 Figure 3. Ghost signals in irradiated and non-irradiated (a) LGADs (W11 C1-V2-2TR) and (b) PIN (W11 C1-V4-2TR) from RD50 production. 3.1.3. AIDAinnova Sensors with Single GR In the trench-isolated sensors from the AIDAinnova production, two important aspects make them different from RD50 samples. LGADs from this production have a gain layer enriched with carbon. In addition, all AIDAinnova sensors feature only a single guard ring, contrary to the multiple GR structure in RD50 samples. These alterations can lead to different ghosts’ behavior. In non-irradiated TI-LGADs from AIDAinnova production, self-induced signal is quite similar to that observed in RD50. It appears above 30 V and increases with bias up to 90 V. Above that value, the signal changes its character, becoming broader and featuring lower amplitude. These signals, assigned before as Type A and Type B (see Section 3.1.1), are shown in Figure 4a. In the corresponding non-irradiated PIN sensor, the ghosts were not observed. After irradiation, the additional type of ghost, present at high bias values, appears in TI-LGAD but also in TI-PIN [11]. Although this signal exhibits very high amplitude (up to 2 V), it is very different from its counterpart recorded in RD50 irradiated sensors. The waveform is very narrow (see Figure 4b) and does not display the multipeak character. This feature is assigned to the fact that only a single guard ring is present in the sensors from AIDAinnova production. Although the difference between the two discussed productions lays not only in GRs configuration but also in gain carbonization (to reduce losses due to irradiation), the observed difference in ghost waveforms is manifested not only in LGADs but also in PINs without gain layer. Hence, the observed effect is only aributed to the difference in GRs. Figure 4. Ghost signals in irradiated and non-irradiated (a) LGADs (V2-2TR TW5 and V3-1TR TW5) and (b) PIN (1TR TW6) from AIDAinnova production. 3.2. Ghosts in Trench-Isolated Sensors with GR Connected to Pad It was clearly observed experimentally that the self-induced signals in RD50 and AIDAinnova trench-isolated sensors behave differently. The observed differences indicate certain correlation with guard rings structure in both families of samples (multiple GRs in RD50 and single GR in AIDAinnova). Since, all observations were recorded for the sensors with floating rings, we decided to test what is the impact of GR potential for self-induced signals. For this purpose, the innermost GR in RD50 sensors and single GR in AIDAinnova samples were connected by additional wire with the neighbor pad (as presented in Figure 2b). After that, all the sensors were examined in exactly the same conditions (bias, temperature) as previously. It turned out that bringing the innermost GR to the same potential as the pad resulted in complete vanishing of ghosts. They were not observed in any circumstances in either LGADs or PINs. Figure 4. Ghost signals in irradiated and non-irradiated (a) LGADs (V2-2TR TW5 and V3-1TR TW5) and (b) PIN (1TR TW6) from AIDAinnova production. 3.2. Ghosts in Trench-Isolated Sensors with GR Connected to Pad It was clearly observed experimentally that the self-induced signals in RD50 and AIDAinnova trench-isolated sensors behave differently. The observed differences indicate certain correlation with guard rings structure in both families of samples (multiple GRs in RD50 and single GR in AIDAinnova). Since, all observations were recorded for the sensors with floating rings, we decided to test what is the impact of GR potential for self-induced signals. For this purpose, the innermost GR in RD50 sensors and single GR in AIDAinnova samples were connected by additional wire with the neighbor pad (as presented in Figure 2b). After that, all the sensors were examined in exactly the same conditions (bias, temperature) as previously. It turned out that bringing the innermost GR to the same potential as the pad resulted in complete vanishing of ghosts. They were not observed in any circumstances in either LGADs or PINs. 3.3. I–V Characteristics for Trench-Isolated LGADs and PINs Since the ghost signal vanishes in all trenched devices after GR connection, the only way to obtain some quantitative differences between investigated GR configurations is to monitor the related changes in leakage current. Sensors 2025,25, 3006 9 of 14 3.3.1. Non-Irradiated Trench-Isolated Sensors IV characteristics of trench-isolated LGADs and PINs were first measured for nonirradiated detectors. In each case, IV curves were recorded for the sensor with floating GR and the same sample when GR is connected to its pad. For that purpose, two different sensors from AIDAinnova production were chosen, one LGAD (V2-1TR TW5 Cell-D TS1) and a corresponding PIN (1TR TW5 Cell-D TS1), both located on the same array. The results for these sensors are presented in Figure 5a,b. In the case of the LGAD, the breakdown voltage shifts about 20 V to higher values when the GR is at the same potential as the pad (Figure 5a). This effect is stronger in the case of the PIN, where the breakdown limit is shifted about 100 V (Figure 5b). All LGAD samples (including those not shown here) with floating GR exhibit a small local maximum in IV curve at the bias around 35 V. This effect disappears when the GR is connected to the pad and it is not observed in the PIN at all. It is probably related to the existence of different depletion regions in LGADs and their merging at certain bias (see discussion in Section 4.1.3). Sensors 2025, 25, x FOR PEER REVIEW 9 of 15 3.3. I–V Characteristics for Trench-Isolated LGADs and PINs Since the ghost signal vanishes in all trenched devices after GR connection, the only way to obtain some quantitative differences between investigated GR configurations is to monitor the related changes in leakage current. 3.3.1. Non-Irradiated Trench-Isolated Sensors IV characteristics of trench-isolated LGADs and PINs were first measured for non-irradiated detectors. In each case, IV curves were recorded for the sensor with floating GR and the same sample when GR is connected to its pad. For that purpose, two different sensors from AIDAinnova production were chosen, one LGAD (V2-1TR TW5 Cell-D TS1) and a corresponding PIN (1TR TW5 Cell-D TS1), both located on the same array. The results for these sensors are presented in Figure 5a,b. In the case of the LGAD, the breakdown voltage shifts about 20 V to higher values when the GR is at the same potential as the pad (Figure 5a). This effect is stronger in the case of the PIN, where the breakdown limit is shifted about 100 V (Figure 5b). All LGAD samples (including those not shown here) with floating GR exhibit a small local maximum in IV curve at the bias around 35 V. This effect disappears when the GR is connected to the pad and it is not observed in the PIN at all. It is probably related to the existence of different depletion regions in LGADs and their merging at certain bias (see discussion in Section 4.1.3). Figure 5. IV characteristics for non-irradiated (a,b), irradiated at 0.8 × 1015 neq/cm2 (c,d), and irradiated at 1.5 × 1015 neq/cm2 (e,f) trench-isolated sensors (LGADs and PINs) from AIDAinnova production. Figure 5. IV characteristics for non-irradiated (a,b), irradiated at 0.8 × 10 15 n eq /cm 2 (c,d), and irradiated at 1.5 × 10 15 n eq /cm 2 (e,f) trench-isolated sensors (LGADs and PINs) from AIDAinnova production. 3.3.2. Irradiated Trench-Isolated Sensors To examine irradiation impact on IV characteristics for the sensors with floating and pad connected GR, four sensors of different features were selected from AIDAinnova production. First, LGAD (V2-1TR TW5 Cell-C TS3) and corresponding PIN (1TR TW2 Cell-C TS3) irradiated to fluence of 0.8 × 10 15 n eq /cm 2 were tested. In both cases, the breakdown voltage was upshifted after connection of GR to pad (see Figure 5c,d). Stronger irradiation at fluency of 1.5 × 10 15 n eq /cm 2 does not change this general trend although it