scieee AI-readable full text Open interactive document viewer

Shapley value-based payment calculation for energy exchange between micro- and utility grids

Pilling, Robin,Chang, Shi Chung,Luh, Peter B.

Abstract

EconStor is a publication server for scholarly economic literature, provided as a non-commercial public service by the ZBW.

Full text

Pilling, Robin; Chang, Shi Chung; Luh, Peter B. Article Shapley value-based payment calculation for energy exchange between microand utility grids Games Provided in Cooperation with: MDPI – Multidisciplinary Digital Publishing Institute, Basel Suggested Citation: Pilling, Robin; Chang, Shi Chung; Luh, Peter B. (2017) : Shapley value-based payment calculation for energy exchange between microand utility grids, Games, ISSN 2073-4336, MDPI, Basel, Vol. 8, Iss. 4, pp. 1-12, https://doi.org/10.3390/g8040045 This Version is available at: https://hdl.handle.net/10419/179155 Standard-Nutzungsbedingungen: Die Dokumente auf EconStor dürfen zu eigenen wissenschaftlichen Zwecken und zum Privatgebrauch gespeichert und kopiert werden. Sie dürfen die Dokumente nicht für öffentliche oder kommerzielle Zwecke vervielfältigen, öffentlich ausstellen, öffentlich zugänglich machen, vertreiben oder anderweitig nutzen. Sofern die Verfasser die Dokumente unter Open-Content-Lizenzen (insbesondere CC-Lizenzen) zur Verfügung gestellt haben sollten, gelten abweichend von diesen Nutzungsbedingungen die in der dort genannten Lizenz gewährten Nutzungsrechte. Terms of use: Documents in EconStor may be saved and copied for your personal and scholarly purposes. You are not to copy documents for public or commercial purposes, to exhibit the documents publicly, to make them publicly available on the internet, or to distribute or otherwise use the documents in public. If the documents have been made available under an Open Content Licence (especially Creative Commons Licences), you may exercise further usage rights as specified in the indicated licence. https://creativecommons.org/licenses/by/4.0/ games Article Shapley Value-Based Payment Calculation for Energy Exchange between Microand Utility Grids Robin Pilling 1,*, Shi Chung Chang 2and Peter B. Luh 3ID 1Graduate Institute of Industrial Engineering, National Taiwan University, Taipei 10617, Taiwan 2Department of Electrical Engineering, National Taiwan University, Taipei 10617, Taiwan; [email protected] 3Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT 06269, USA; peter[email protected] *Correspondence: [email protected]; Tel.: +49-6127-3818 Received: 31 July 2017; Accepted: 11 October 2017; Published: 23 October 2017 Abstract: In recent years, microgrids have developed as important parts of power systems and have provided affordable, reliable, and sustainable supplies of electricity. Each microgrid is managed as a single controllable entity with respect to the existing power system but demands for joint operation and sharing the benefits between a microgrid and its hosting utility. This paper is focused on the joint operation of a microgrid and its hosting utility, which cooperatively minimize daily generation costs through energy exchange, and presents a payment calculation scheme for power transactions based on a fair allocation of reduced generation costs. To fairly compensate for energy exchange between the microand utility grids, we adopt the cooperative game theoretic solution concept of Shapley value. We design a case study for a fictitious interconnection model between the Mueller microgrid in Austin, Texas and the utility grid in Taiwan. Our case study shows that when compared to standalone generations, both the microand utility grids are better off when they collaborate in power exchange regardless of their individual contributions to the power exchange coalition. Keywords: energy exchange; cooperative game theory; microgrid economics; Shapley value 1. Introduction The integration of changing technologies and new entrants in the generation market requires major changes in the operations of the electricity market to become smarter in order to provide an affordable, reliable, and sustainable supply of electricity [ 1 , 2 ]. To enhance the reliability and reduce the costs of an integrated transmission grid, the smart grid concept has encouraged researchers [ 3 – 5 ] to study ways of generating power locally in proximity to the customer through combining together loads and distributed generation (DG) in so called microgrids. A microgrid is a network of small-scale distributed energy resources (DER), such as solar panels, wind turbines, fuel cells, and micro-turbines that can either operate standalone or interconnected to the utility grid. Its feature to be managed as a single controllable entity with respect to the existing power system poses several benefits, and demands for joint operation models with the utility network. To incentivize collaboration in energy exchange between a microgrid and its hosting utility, however, we analyzed three inter-related design problems that will be addressed in the remainder of this research: the joint operation, cost allocation, and the payment calculation problem. Therefore, we first analyze the design problems for collaboration in energy exchange, then present a centralized decision model for the joint operation of a microgrid and its hosting utility, and finally suggest a payment calculation scheme that compensates for energy exchange based on fairly allocating joint generation costs. In this regard, we adopt the cooperative game theoretic solution concept of Shapley value to fairly allocate reduced generation costs from joint operation and incentivize Games 2017,8, 45; doi:10.3390/g8040045 www.mdpi.com/journal/games Games 2017,8, 45 2 of 12 generation cost savings that can be realized when the microand utility grids form a coalition through mutual payments for energy exchange. 1.1. Joint Operation Problem According to Hogan [ 1 ], the problem of how to jointly deliver an aggregated load schedule involving multiple power grids has initially been discussed for vertically integrated utilities in regulated energy markets. To address the problem, utilities traditionally formed coalitions, e.g., in the form of power pools, to jointly dispatch their generation resources and thereby achieve cost savings. In this regards, Chattopadhyay [ 6 ] presents a linear programming (LP) formulation of an energy brokerage system, which maximizes the savings for interconnected utilities participating in a power pool. Particularly against the background of the benefits that arise from an energy exchange between a microgrid and its extant power system, this is also an issue for the joint operation of a microgrid and its hosting utility. Distributed energy trading concepts help power grids to cooperatively gain and share the benefits through economies of scale and making the best use of all available resources; among others by reducing system operation costs through access to linked generation resources, which may improve generation decisions. An overview of distributed energy trading concepts for microgrids is provided by Bayram et al. [ 7 ]. In this context, Asimakopoulou et al. [ 8 ] discusses decision models for the interaction between the utility and the microgrid. As our research cooperatively optimizes energy management between the utility and the microgrid to maximize total cost savings of both power grids, we suggest a centralized decision framework where a centralized planer solves the interaction between the power grids as a single objective maximization problem to jointly optimize available generation units. Since there is only one entity, our joint generation cost model represents the ideal case of adducing an aggregated load schedule without a profit margin for energy exchange and describes the best way to achieve joint cost savings between the microand utility grid. 1.2. Cost Allocation Problem Notwithstanding, a major obstacle for the collaboration in energy exchange still constitutes the application of a cost sharing rule that fairly allocates the potential costs saving benefit from jointly delivering an aggregated load schedule when the networks cooperate as a single unit. In recent years, the theoretical analysis to develop criteria and methods for cost allocation problems emerged as the field of cost sharing games. The methods to define and solve cost sharing games are summarized by Jain et al. [9]. Cost sharing games provide a proper basis to allocate the costs for a group of parties that wants to divide the cost of a common facility or operation. In this regard, each party has a standalone cost if it does not cooperate with the others. Similarly, each subgroup of parties has a shared cost if parties cooperate with each other but not with the remaining parties. Even though cost sharing games allow the assessment of the value of a coalition in the context of a given scenario, they do not solve the problem how the value should be shared. Therefore, a cost sharing rule can help to allocate the total cost among the members of a group for every possible cost sharing game. To address a common cost allocation problem, several methods have been discussed for the distribution of joint cost and the division of surplus, among others the Shapley value [ 10 ]. The Shapley value was introduced by Shapley [ 11 ] as a method for players to assess, a priori, their benefits from playing a game and suggested as a joint-cost allocation scheme in various fields of research. Today, the Shapley value is perhaps the most commonly used method to allocate the costs in cost sharing games as it is budget-balanced and guarantees equilibrium existence in any game, regardless of its parameters [12]. In the power market environment, the Shapley value finds many applications, e.g., when fairly allocating emission [ 6 ] or transmission expansion [ 13 ] costs. Its many applications and favorable Games 2017,8, 45 3 of 12 properties to support a mutually agreeable division of costs motivate us to set up a decision model that exhibits cost savings for the joint generation of a microand utility grid, and suggest a payment calculation scheme that fairly compensates for energy exchange through payments for mutual power transactions. 1.3. Payment Calculation Problem As Shapley values express fair cost contributions of the microand utility grids to the coalition of jointly delivering an aggregated load schedule, but does not compensate for energy exchange through mutual payments, this research adopts the Shapley value concept to suggest a payment calculation scheme for energy exchange based on fairly allocating joint generation costs. In this regard, we calculate the fair payments for mutual power transactions as the difference of the Shapley values and the actual generation cost of each grid under joint generation. In other words, applying the Shapley value helps to reconcile for an equitable allocation of operation costs and transaction payments for energy exchange between the systems. Figure 1illustrates the payment calculation scheme for energy exchange as presented in this research. Games 2017, 8, 45 3 of 12 that exhibits cost savings for the joint generation of a microand utility grid, and suggest a payment calculation scheme that fairly compensates for energy exchange through payments for mutual power transactions. 1.3. Payment Calculation Problem As Shapley values express fair cost contributions of the microand utility grids to the coalition of jointly delivering an aggregated load schedule, but does not compensate for energy exchange through mutual payments, this research adopts the Shapley value concept to suggest a payment calculation scheme for energy exchange based on fairly allocating joint generation costs. In this regard, we calculate the fair payments for mutual power transactions as the difference of the Shapley values and the actual generation cost of each grid under joint generation. In other words, applying the Shapley value helps to reconcile for an equitable allocation of operation costs and transaction payments for energy exchange between the systems. Figure 1 illustrates the payment calculation scheme for energy exchange as presented in this research. Figure 1. Payment Calculation Scheme for Energy Exchange. The payment calculation scheme determines the cost saving benefit from joint generation and applies the Shapley value to allocate the saving benefit between the microand utility grids based on their individual marginal cost contributions to the power exchange coalition. Against the background of different cost contributions, the Shapley value function incentivizes the joint cost optimization and helps to compensate for energy exchange by fairly calculating the payments for the energy exchange between the utility and the microgrid. 2. Shapley Value-Based Decision Model This research assumes a privately owned microgrid and a hosting utility that operates as interconnected power systems with the objective to minimize individual daily generation costs through energy exchange. Further, we assume that each system has sufficient generation resources to meet its own loads, and can make a decision on whether to operate standalone or in joint generation. To motivate energy exchange between the microgrid and the utility, we first determine the daily generation costs of standalone operations with no power exchange. We then introduce a coalition model for the two power grids to cooperatively minimize total daily generation costs through energy exchange, where available generation units are centrally committed and dispatched to deliver an aggregated load schedule. Based on realized cost savings by the coalition in comparison to standalone operations, we adopt the solution concept of Shapley value to determine the respective contributions to cost savings by the Figure 1. Payment Calculation Scheme for Energy Exchange. The payment calculation scheme determines the cost saving benefit from joint generation and applies the Shapley value to allocate the saving benefit between the microand utility grids based on their individual marginal cost contributions to the power exchange coalition. Against the background of different cost contributions, the Shapley value function incentivizes the joint cost optimization and helps to compensate for energy exchange by fairly calculating the payments for the energy exchange between the utility and the microgrid. 2. Shapley Value-Based Decision Model This research assumes a privately owned microgrid and a hosting utility that operates as interconnected power systems with the objective to minimize individual daily generation costs through energy exchange. Further, we assume that each system has sufficient generation resources to meet its own loads, and can make a decision on whether to operate standalone or in joint generation. To motivate energy exchange between the microgrid and the utility, we first determine the daily generation costs of standalone operations with no power exchange. We then introduce a coalition model for the two power grids to cooperatively minimize total daily generation costs through energy exchange, where available generation units are centrally committed and dispatched to deliver an aggregated load schedule. Based on realized cost savings by the coalition in comparison to standalone operations, we adopt the solution concept of Shapley value to determine the respective contributions to cost savings by the Games 2017,8, 45 4 of 12 microgrid and the utility. The final part of the decisions is who should pay whom by how much in order to fairly compensate for power transactions. 2.1. Notations/Nomenclature Index/sets gDistributed generation (DG) units; sEnergy storage units; uUtility generating units; tTime periods in 1-hour increments. Parameters JM( ) Microgrid generation cost function; AgConstant from generation cost curve for DG unit g; BgFirst order component of generation cost curve for DG unit g; CgSecond order component of generation cost curve for DG unit g; JU( ) Utility generation cost function; AuConstant from generation cost curve for aggregated utility unit u; BuFirst order component of generation cost curve for aggregated utility unit u; Cu Second order component of generation cost curve for aggregated utility unit u. Power limits Pg min Minimum power level of DG unit g(MW); Pg max Maximum power level of DG unit g(MW); Pu min Minimum power level of the utility (MW); Pu max Maximum power level of the utility (MW). Energy storage system (ESS) ηc/ηdCharging/discharging efficiency for energy storage system of type s; Es max Maximum capacity of energy storage system of type s(MWh); Es min Minimum capacity of energy storage system of type s(MWh); Pcs max Maximum amount that can be added (charged) to storage (MW); Pds min Maximum amount that can be drawn (discharged) from storage (MW). (Given) Forecasts PR,tSum of power production from renewable energy supply (MW); DM,tPower level demanded from the microgrid loads at time t; DU,tPower level demanded from the utility loads at time t. Decision and logical variables Pu,tPower generated by aggregated utility unit in period t(MW); Pg,tPower generated by DG unit gin period t(MW); yg,tBinary indicating if a unit gis on or off in period t; Es,tEnergy stored in energy storage system sat the end of period t(MW); Ps,tPower output from storage unit sin period t(MW); Pcs,tPower charged to storage unit sin period t; Pds,tPower discharged by storage unit sin period t; nsNumber of storage unit sin period t. 2.2. “As-If” Standalone Generation Cost Models without Energy Exchange To calculate the individual generation costs from standalone grid operations, the decision model is inserted into the architecture of a single microgrid and a utility grid with fixed system configurations and deterministic input variables that consider their individual load profiles and generation constraints. Although Bayram et al. [ 7 ] suggests additional criteria for the definition of microgrids, e.g., controllable loads, the ability to operate in islanding mode or combined heat and power (CHP), our Games 2017,8, 45 5 of 12 study only concerns about the electric system of a microgrid with the aim to suggest a proper basis for operational cost sharing with the electric utility. Given a microgrid with a fixed configuration of distributed generation, a renewable energy source and an energy storage system, the unit commitment (UC) and economic dispatch (ED) for minimum cost generation to meet microgrid loads is formulated as a mixed integer programming [ 14 ] problem. To compute the utility’s generation costs under given demands, we treat the utility as an aggregated generation unit, of which the hourly generation cost function is obtained by solving the UC & ED problem of the utility over different load levels, as proposed by Chang et al. [15]. 2.2.1. Microgrid Cost Model Our study describes the deterministic case of an optimization model with determined inputs for the specific dispatch scenario of a summer and a winter day. In this respect, the microgrid produces power from a fixed installed capacity of intermittent renewable energy supply (i.e., solar power) and distributed energy resources (i.e., a gas turbine) to meet the loads demanded by the consumers. For the design of our cost model, renewable energy sources are indicated with zero marginal costs to make sure that renewable generation is fully dispatched. The aggregated power output from renewables is calculated to the effect of ambient conditions (i.e., solar irradiation) and treated as a negative load for any given load level. Energy storage can help to store excess power and reduce distributed generation in future periods. Excess renewable power is lost in cases where the output from renewable energy exceeds the energy storage capacity. After determining the power output from renewable energy production, the remaining power output from distributed generation for each load level can be determined. Distributed energy resources generate power whenever renewables and energy storage are insufficient to fully serve the load. The decisions include two parts: whether to commit a distributed energy unit and how much power by a committed unit. The binary UC variables yg,t are 0–1 integer variables corresponding to ON-OFF decisions and Pg,t are continuous ED variables for the generation power levels. Given a microgrid with a fixed configuration, the mixed integer programming problem of UC & ED for system demand satisfaction and generation cost minimization is formulated as follows: The generation cost of each distributed generation unit is a quadratic function of the generation power level. The UC decisions, yg,t , and ED decisions, Pg,t , must meet various microgrid and unit constraints, and minimize the total generation cost of all the committed distributed generation units over one day as described in Equations (1)–(9). min Pg,t yg,t ∑ t∈T ∑ g∈G yg,t×Ag×Pg,t2+Bg×Pg,t+Cg(1) As the loads must be met at all times in a power system, Equation (2) requires the model to have sufficient generation available to balance demand and supply. Renewable generation is included as negative loads and assumed to be fully dispatched with zero marginal costs. ∑ g yg,tPg,t=DM,t−PR,t,∀t. (2) In addition, there are minimum and maximum power levels for the DG generation units applied to the power output Pg,t, which are presented in Equation (3). Pg min ≤Pg,t≤Pg max, if yg,t=1, Pg,t=0, if yg,t=0, ∀g,t. (3) Games 2017,8, 45 6 of 12 The implementation of a discrete storage system does not directly affect the objective function but adds storage specific constraints on power flow through charging and discharging of the storage system as represented in Equations (4)–(6). Equation (4) is the energy balance equation of a storage unit sfor a time period considering energy conversion efficiencies, Es,t+1=Es,t−Pd s,t ηd +Pc s,t×ηc∀s,t. (4) Equation (5) defines the total power output Ps,t of storage as the difference of total discharging power Pd s,tand total charging power Pc s,t, where we assume constant power in one time period. ∑ sPd s,t−Pc s,t=∑ s Ps,t∀t. (5) Besides Equation (2), the total power supply by the distributed generation and storage units should be more than the difference between the demand and renewable power generation of the microgrid. The total storage output power can be either positive or negative in value. The power balance constraint with inclusion of storage is obtained by modification of that in [16] as follows: ∑ g yg,tPg,t+∑ s Ps,t≥DM,t−PR,t∀t. (6) Similar to distributed generation units, storage units are also constraint by power limits (charging rates) and storage limits (battery sizes) as expressed by Equations (7.a) and (7.b). 0≤Pds,t≤ns×Pds max ∀s,t. (7.a) 0≤Pcs,t≤ns×Pcs max ∀s,t. (7.b) The limits for the minimum Es min and maximum storage Es max are shown in Equation (8). ns×Es min ≤Es,t≤ns×Es max ∀s,t. (8) Finally, a terminal equality constraint that requires the starting E0 and ET ending limits of the storage in the battery to be equal is set up in Equation (9). E0=ET(9) 2.2.2. Utility Cost Model To obtain the utility cost function that minimizes generation costs, we aggregate all of the available thermal units of the utility network into one equivalent aggregate thermal unit. The ideal definition of an aggregate unit will meet some objective across all levels of output of an aggregate unit [ 17 ]. Therefore, we perform unit commitment and economic dispatch over the set of all available thermal units to find the minimized generation cost for each given load level. Next, we derive the aggregated thermal unit by fitting a cost function to the data points of generation cost at each load level. The thermal cost function is approximated by a second order polynomial. The aggregate thermal cost functions for summer (S) and winter days (W) are shown in Table 1. Relevant cost functions were generated based on different model periods and numbers of thermal generation units. Generation specific information on the thermal generating fleet was provided by Taipower Company. For our studies, we use the cost functions obtained for a scheduling period of 24 h during both summer and winter days. In this regards, we assume that the cost functions for a period of 24 h stays the same every day in a week. Games 2017,8, 45 7 of 12 Table 1. Aggregated Thermal Unit of the Taipower Company (in $). Scheduling Horizon (in h) No. of Plants Cost Function of the Aggregated Thermal Unit (in $) 1 24 3 0.0025 ×P2−8.95 ×P+41077 24 7 0.0024 ×P2−5.20 ×P+23519 24 10 (W) 0.0021 ×P2−7.84 ×P+78526 24 10 (S) 0.00235 ×P2−12.08 ×P+94142 72 10 0.0021 ×P2−7.84 ×P+78526 168 10 (W) 0.0021 ×P2−7.84 ×P+78526 168 10 (S) 0.00235 ×P2−12.08 ×P+94142 1USD to TWD = 31 $. 2.3. Joint Generation Cost Model with Energy Exchange To develop a joint generation cost model for the energy exchange between a microgrid and its hosting utility, it will be assumed that the utility and the microgrid each with their own generation and loads are operating as an interconnected power system where generation is centrally dispatched. In this regard, a centralized market coordinator with complete information regarding the cost functions of all generation units is assumed. Based on this information, its responsibility is to independently dispatch all of the available generation resources and minimize the joint generation cost from delivering an aggregate load schedule. As mentioned before, in the coalition model between microgrid and utility, there is only one single decision entity and the objective is to minimize daily joint generation costs in an idealistic way by adducing a joint load schedule. The joint generation cost can thus be expressed as a sum of the aggregate cost function of the utility and microgrid generation costs, as presented in Sections 2.1 and 2.2. The objective function of the joint generation cost model is presented in Equation (10). min Pg,t Pu,t yg,t ∑ t∈T ∑ g∈G yg,t×Ag×Pg,t2+Bg×Pg,t+Cg+∑ t∈TAu×Pu,t2+Bu×Pu,t+Cu(10) As the loads of both system must be balanced, Equation (2) requires sufficient power generation to fully adduce a joint schedule during all of the time periods. Renewable generation is assumed to be fully dispatched with zero marginal costs and included as deterministic negative loads. ∑ g yg,tPg,t+Pu,t=DM,t+DU,t−PR,t∀g,t(11) In addition to the power balance constraints, Equations (12.a) and (12.b) include minimum and maximum power levels for the distributed and utility generation units applied to the power outputs Pg,tand Pu,t, respectively. Pg min ≤Pg,t≤Pg max, if yg,t=1, ∀g,t. (12.a) Pg,t=0, if yg,t=0, Pu min ≤Pu,t≤Pu max ∀t(12.b) Storage specific constraints are the same as Equations (4)–(9), where the power balance constraint with inclusion of storage is obtained by modification of Equation (6) as follows: ∑ g yg,tPg,t+Pu,t+∑ s Ps,t≥DM,t+DU,t−PR,t∀g, t. (13) To solve the problem, the decision model is implemented in ILOG CPLEX 12.2 as a mixed-integer quadratic programming (MIQP) problem with second order cost functions to dispatches all available Games 2017,8, 45 8 of 12 generation resources and minimize the joint generation cost from delivering an aggregate load schedule. CPLEX helps to effectively solve the problem—where the restriction of the problem to its continuous and general integer variables is a convex quadratic program (QP)—as a commercial MIQP solver instead of using standard algorithms. 2.4. Shapley Value Based Decision Model and Payment To calculate the payments of power exchanged, a method that fairly accounts for individual cost and generation contributions to the joint operation is needed. The Shapley value constitutes as such a method and helps us to compensate for energy exchange through fair payments for power .transactions between the power systems due to a mutually agreeable division of joint operation costs. The idea is that given a cost sharing game, players join the game one at a time in some predetermined order. As each player joins, a player’s cost contribution is its net addition to the cost as it joins. The Shapley value of a player is its average cost contribution over all possible orderings of the players and supports a mutually agreeable division of costs with certain fairness properties [ 18 ]. Mathematically, the Shapley value ϕiof player ican be expressed as ϕi(υ)=∑ S⊆N{i} |S|!(n−|S|−1)! n!×[υ(S∪{i})−υ(S)](14) where Sis the number of players in the coalition, Nis the total number of players in the game, υ is the characteristic function representing the total jointly earned payoff or benefit of a coalition S, and iis any player in the game. The term, v(S ∪ {i}) − v(S), refers to the marginal contribution of player ito the value of the whole coalition v(S). Further, the expression |S|!(n−|S|−1)! n! depicts the weighting factor that allocates a proportional share of marginal contribution of each player in the coalition. As a result, the Shapley value ϕi is assigned to a player iaccording to a given function vthat determines the gain v(S) for a coalition game (N,v) with transferable utility for player set N measured by a function vfor any non-empty subset S ⊆ N. The advantages of this method are that this approach is budget-balanced and guarantees equilibrium existence in any game regardless of its parameters. Also, it has some important properties that hold when allocating the cost in a cost sharing game [18]: 1. Pareto-efficiency: The total value of a coalition is distributed among the members: ∑ i∈N ϕi(υ)=υ(N). 2. Symmetry: The value can be determined regardless of the name of the players. If for any two players iand jthe following holds: υ(S∪{i}) = υ(S∪{j}) for every subset S ⊆ Nwith S∩{i,j}=∅, then ϕi(υ)=ϕj(υ). 3. Additivity: This property requires for any two games ϕi(N,υ) , ϕi(N,υ∗) that: ϕi(N,υ)+ ϕi(N,υ∗)=ϕi(N,υ+υ∗)∀i∈N. 4. Zero player: If the marginal value of a player to any possible coalition is zero, this player gains a value of zero: υ(S∪{i}) = υ(S)∀S⇒ϕi(υ)=0. 3. Case Study Results We design a fictitious interconnection model between the Mueller microgrid in Austin, Texas, and the utility grid in Taiwan for case study to share the savings from their coalition through fair payments for energy exchange and validate out model. Our results are presented for the residential load and PV generation data obtained for the Mueller community as of April 2015 from the Pecan Street Database. The weekly load profile for the Taiwan utility was obtained from Chang et al. [ 15 ] and considered for a single day period. The load of a winter day is in average 25% lower than the load of a summer because there is no need for air conditioning or heating in the winter.