Full text
coatings Article Antimicrobial Efficacy of Low Concentration PVP-Silver Nanoparticles Deposited on DBD Plasma-Treated Polyamide 6,6 Fabric Ana Isabel Ribeiro 1, Dilara Senturk 1, Késia Karina Silva 2, Martina Modic 3, Uros Cvelbar 3, Gheorghe Dinescu 4, Bogdana Mitu 4, Anton Nikiforov 5, Christophe Leys 5, Irina Kuchakova 5, Mike De Vrieze 6, António Pedro Souto 1and Andrea Zille 1,* 12C2T-Centro de Ciência e Tecnologia Têxtil, Universidade do Minho, Campus de Azurém, 4800-058 Guimarães, Portugal; [email protected] (A.I.R.); [email protected] (D.S.); [email protected] (A.P.S.) 2Department of Textile Engineering, Federal University of Rio Grande do Norte, Natal/RN 1524, Brazil; [email protected] 3Jožef Stefan Institute, 1000 Ljubljana, Slovenia; [email protected] (M.M.); [email protected] (U.C.) 4National Institute for Lasers, Plasma and Radiation Physics, 077125 Măgurele, Romania; [email protected] (G.D.); [email protected]o (B.M.) 5 Department of Applied Physics, Ghent University, 9000 Ghent, Belgium; [email protected] (A.N.); [email protected] (C.L.); [email protected] (I.K.) 6Centexbel Ghent, Technologie park 7, 9052 Ghent, Belgium; Mike.DeV[email protected] *Correspondence: [email protected] Received: 1 August 2019; Accepted: 12 September 2019; Published: 14 September 2019 Abstract: In this study, a low concentration (10 µ g · mL −1 ) of poly(N-vinylpyrrolidone) (PVP)-coated silver nanoparticles (AgNPs) were deposited by spray and exhaustion (30, 70 and 100 ◦ C) methods onto untreated and dielectric barrier discharge (DBD) plasma-treated polyamide 6,6 (PA66) fabric. DBD plasma-treated samples showed higher AgNP deposition than untreated ones for all methods. After five washing cycles, only DBD plasma-treated samples displayed AgNPs on the fabric surface. The best-performing method was exhaustion at 30 ◦ C, which exhibited less agglomeration and the best antibacterial efficacy against S. aureus (4 log reduction). For E. coli, the antimicrobial effect showed good results in all the exhaustion samples (5 log reduction). Considering the spray method, only the DBD plasma-treated samples showed some bacteriostatic activity for both strains, but the AgNP concentration was not enough to have a bactericidal effect. Our results suggest DBD plasma may be a low cost and chemical-free method for the preparation of antibacterial textiles, allowing for the immobilization of a very low—but effective—concentration of AgNPs. Keywords: silver nanoparticles; dielectric barrier discharge; plasma; antimicrobial; exhaustion; spray 1. Introduction Progressive growth in antimicrobial resistance is leading to the rise of recalcitrant infections, complications of illness and mortality. Thus, there is great demand for the development of new antimicrobial agents and materials [ 1 ]. Silver ions display intrinsic antimicrobial, antiviral and anti-inflammatory properties and have been used—mostly in the form of silver salts—in medical textiles for wound dressings, surgical sutures and medical staffuniforms [ 2 , 3 ]. Recent developments in nanotechnology have created new advantages for silver-based antimicrobial textiles. The unique chemical and physical properties and high surface–volume ratio of silver nanoparticles (AgNPs) have Coatings 2019,9, 581; doi:10.3390/coatings9090581 www.mdpi.com/journal/coatings
Coatings 2019,9, 581 2 of 14 made this new tool an extremely efficient antimicrobial agent [ 4 – 6 ]. The size, concentration and distribution of AgNPs onto textile substrates is fundamental to the balance and control of antimicrobial efficacy and cytotoxicity [ 7 ]. Indeed, AgNPs can be cytotoxic to human cells if small-sized nanoparticles (less than 15 nm) and high concentrations are prescribed to patients [ 8 ]. Numerous techniques can be applied to deposit nanoparticles onto textiles, including aerosol, electrospray, convective assembly, sputtering, spin-coating, evaporation, dip-coating, exhaustion, impregnation, chemical vapor deposition and sonochemical immobilization [ 9 , 10 ]. However, most of obtained textiles possess AgNPs with weak adhesion, irregular distribution or a high degree of agglomeration [ 11 ]. AgNP capping agents, such as oleic acid, polyacrylic acid, polyethylene glycol (PEG), polyvinyl alcohol (PVA), and poly(N–vinylpyrrolidone) (PVP), are commonly used to prevent agglomeration during AgNP synthesis or dispersion preparation. Despite this, agglomeration can still occur during the deposition process onto textiles, even when capping agents are used [12,13]. One efficient strategy to avoid such drawbacks, enhance antimicrobial efficacy and reduce cytotoxicity can be the concomitant application of three conditions: (i) Decrease AgNP concentration, (ii) reduce agglomeration, and (iii) improve bonding between the AgNPs and textile substrates [ 11 , 14 ]. Double dielectric barrier plasma discharge techniques have been tested in the last years and revealed as a promising technique for textile coatings adhesion, including AgNPs [ 15 ]. Dielectric barrier discharge (DBD) plasma treatment is faster and more environmentally friendly than chemical surface modification techniques, which act exclusively on the material surface without affecting the bulk properties [ 16 ]. Moreover, when DBD plasma is operated in air, without the use of expensive carrier gases, this technique is very cost-effective [ 17 ]. Oxidation reactions during DBD plasma treatment in air generate polar functional groups that may improve the hydrophilicity of the material, creating highly reactive species on its surface [ 18 ]. Additionally, reactive oxygen species (ROS) and reactive nitrogen species (RNS) produced during DBD plasma treatment in air can also have antimicrobial action [ 19 ]. Plasma-assisted deposition of AgNPs also includes the formation of micro-roughness, which can enhance the adhesion and washing fastness of AgNPs [20]. In this study, polyamide 6,6 (PA66) fabric samples with and without DBD pre-treatment were coated with a low concentration of PVP-coated AgNPs by exhaustion (at 30, 70 and 100 ◦ C) and spray methods. This is the first time that a such low concentration of AgNPs was systematically studied for its potential in antimicrobial textile fabrics. The concentration of AgNPs on the PA66 surface was evaluated before and after five washing cycles. FTIR, reflectance spectroscopy, SEM and XPS techniques were performed in order to understand the nature of the interactions between the AgNPs and fabric surface. Antibacterial analyses were also performed against Gram-negative Escherichia coli and Gram-positive Staphylococcus aureus bacteria. 2. Materials and Methods Commercial polyamide 6,6 fabric with a warp density of 50 threads · cm −1 , a weft density of 32 threads · cm −1 , and a weight per unit area of 110 g · m −2 was used. The fabric was firstly washed with 1 g · L −1 of a non-ionic detergent in water solution at 60 ◦ C for 60 min, rinsed with distilled water and then dried at 40 ◦ C to minimize contaminants. PVP AgNPs (~20 nm) were acquired from Sigma–Aldrich (St. Louis, MO, USA) and used without purification. The DBD plasma treatment was performed at atmospheric pressure and room temperature in a semi-industrial prototype machine (Softal GmbH/University of Minho, Guimar ã es, Portugal), using metal electrodes coated with ceramic and counter electrodes coated with silicon. The electrodes, with a 50 cm effective width and gap distance of 3 mm, produced the discharge at low frequency (40 kHz) and high voltage (10 kV). The speed of the machine and discharge power of the electrodes could be modified, with a maximum speed of 60 m · min −1 and discharge of 1.5 kW. In this study, the machine was operated at 1 kW of power and a velocity of 4 m · min −1 , as these have been previously reported as the optimized conditions for PA66, corresponding to a dosage of 5 kW min · m −2 [ 17 ]. The estimated temperature of DBD atmospheric plasma in air is near to room temperature. However,
Coatings 2019,9, 581 3 of 14 taking into account a by-product reaction with air and treated polymers, a temperature up to 400 K can be attained [21,22]. The surface wettability of the untreated and plasma-treated fabrics was characterized with Dataphysics equipment using OCA20 software with a video system for capturing images in static mode. PVP–AgNP dispersions (10 µ g · mL −1 ) in water were prepared using a Branson 3510 ultrasonic bath for 30 min and an Optic Ivymen System CY-500 ultrasonic tip for more than 30 min. PVP–AgNPs were deposited in 5 × 5 cm 2 PA66 samples with and without DBD plasma pre-treatment. PVP–AgNP dispersions were applied by (i) spray on both sides, where the system was maintained at a distance of 5 cm from the substrate and pressurized at 1.5 bar, and by (ii) exhaustion in a laboratory-dyeing machine (Ahiba, Datacolor, Lawrenceville, NJ, USA) at 30, 70 and 100 ◦ C for 60 min, 40 rpm with a 1:100 ratio bath. All samples were dried at room temperature. The washing fastness of PVP–AgNPs deposited onto PA66 samples was evaluated after five washing cycles in a laboratory-dyeing machine (Ahiba, Datacolor, Lawrenceville, NJ, USA) at 75 ◦ C and 40 rpm for 15 min with 0.1 g · L −1 of a non-ionic surfactant in a liquor bath ratio of 1:30, according to EN ISO 15797 (industrial washing) [23]. A Shimadzu IRAffinity-1S FTIR spectrophotometer with an attenuated total reflectance (ATR, Preiser Scientific, Saint Albans, WV, USA) accessory equipped with a 1 reflection diamond crystal was used to record the FTIR–ATR spectra of the fabrics, performing 45 scans at a spectral resolution of 4 cm −1 over the range 400–4000 cm −1 . Samples with and without DBD plasma treatment were analyzed. The diffuse reflectance spectra of the untreated and plasma-treated PA66 fabrics with adsorbed PVP–AgNPs were obtained using a Spectraflash 600 (Datacolor, Lawrenceville, NJ, USA) spectrophotometer at standard illuminant D65 (LAV/Spec. Excl., d/8, D65/10 ◦ ). The reflectance data were presented as a percentage in the AgNPs maximum wavelength absorbance (420 nm). Untreated and DBD plasma-treated PA66 samples with and without AgNPs were evaluated in triplicate. MorphologicalanalysesofPA66fabricswereperformedwithanultra-highresolutionfieldemission gun–scanning electron microscope (FEG–SEM; NOVA 200 Nano SEM, FEI Company, Hillsboro, OR, USA). The secondary electron images were carried out with an acceleration voltage at 5 kV, while the backscattering electron images were obtained with an acceleration voltage of 15 kV. A film of Au–Pd (80–20 wt %) was used to coat the samples using a high-resolution sputter coater (208HR Cressington Company, Watford, United Kingdom) coupled to an MTM-20 Cressington High Resolution Thickness Controller. XPS analyses were carried out using a Kratos AXIS Ultra HSA (Kratos Analytical, Manchester, United Kingdom) with VISION software for data acquisition. The analysis was achieved using a monochromatic Al K α X-ray source (1486.7 eV), which was operated at 15kV (150 W) in FAT mode (Fixed Analyzer Transmission), with a pass energy of 40 eV for the region of interest and 80 eV for the survey spectra. The working pressure was maintained lower than 1 × 10 6 Pa and a charge neutralization system was used. The binding energy scale was adjusted according to the C1sspectral component at 285.9 eV. The high-resolution spectra were obtained considering an analysis area of ≈1 mm2 . The full width at half maximum (FWHM) of the main peak was considered for the other peaks; this process introduced an associated error of ± 0.1 eV. The spectra analyses for elemental composition were performed with CASAXPS software (version 2.3.15). Deconvolutions were achieved by XPSPEAK (version 4.1) using the least squares method, which fit the data with the Gaussian/Lorentzian sum function after Shirley-type background subtraction. The tailing function was not considered during the fitting process. The antibacterial efficacy of the PA66 samples was assessed according to the quantitative standard shake flask method (ASTM-E2149-01) [ 24 ]. Gram-positive Staphylococcus aureus (S. aureus, ATCC 6538) and Gram-negative Escherichia coli (E. coli, ATCC 25922) bacteria were used. Any contamination was prevented by conducting the experiment aseptically. Bacteria inoculum in tryptic soy broth (TSB, Merck) were processed from a single colony and incubated for 12 h at 37 ◦ C and 120 rpm. An initial concentration of 1.5–3.0 × 10 7 CFUs/mL in PBS was used. PA66 fabrics (0.05 g weight) were incubated
Coatings 2019,9, 581 4 of 14 in 5 mL of bacteria suspension for 24 h at 37 ◦ C and 100 rpm. Before (0 h) and after the contact with samples (24 h), the bacteria were serially diluted and cultured onto tryptic soy agar (TSA, Merck) plates, and incubated for more than 24 h. After this period, the colonies of surviving bacteria on the agar plates were counted. Antimicrobial activity was presented as a log reduction, calculated as the ratio between the number of surviving bacteria colonies, before and after contact with the samples. All antimicrobial tests were performed in triplicate. 3. Results 3.1. FTIR–ATR Analyses of Untreated and Plasma-Treated PA66 Samples As shown in Figure 1, the FTIR spectra of untreated and DBD plasma-treated PA66 possess the typical bands of polyamide at 3290, 2931 and 2858 cm −1 , attributable to NH 2 stretching, CH 2 asymmetric, and symmetric stretching vibrations, respectively. The strong intensity peaks of amide carbonyl N–C=O (amide I) and N–H bending from amide II are exhibited at 1630 cm −1 and 1530 cm −1 . The band at 680 cm −1 represents the bending of the O=C–N group. A particularity of the samples with plasma treatment is the presence of a new weak band at 1728 cm −1 . This band may be attributed to the C=O stretching of ketones, aldehydes and carboxylic acids, formed by reactive oxygen species during plasma discharge [25,26]. Moreover, after plasma treatment, some change can be noted in the characteristic crystalline peaks of PA66 at 930 cm −1 and 1200 cm −1 , attributable to the amide axial deformation (C–C=O) and symmetrical angular deformation of out of plane amide III, respectively. Coatings 2019, 9, x FOR PEER REVIEW 4 of 14 were incubated in 5 mL of bacteria suspension for 24 h at 37 C and 100 rpm. Before (0 h) and after the contact with samples (24 h), the bacteria were serially diluted and cultured onto tryptic soy agar (TSA, Merck) plates, and incubated for more than 24 h. After this period, the colonies of surviving bacteria on the agar plates were counted. Antimicrobial activity was presented as a log reduction, calculated as the ratio between the number of surviving bacteria colonies, before and after contact with the samples. All antimicrobial tests were performed in triplicate. 3. Results 3.1. FTIR–ATR Analyses of Untreated and Plasma-treated PA66 Samples As shown in Figure 1, the FTIR spectra of untreated and DBD plasma-treated PA66 possess the typical bands of polyamide at 3290, 2931 and 2858 cm−1, attributable to NH2 stretching, CH2 asymmetric, and symmetric stretching vibrations, respectively. The strong intensity peaks of amide carbonyl N–C=O (amide I) and N–H bending from amide II are exhibited at 1630 cm−1 and 1530 cm−1. The band at 680 cm−1 represents the bending of the O=C–N group. A particularity of the samples with plasma treatment is the presence of a new weak band at 1728 cm−1. This band may be attributed to the C=O stretching of ketones, aldehydes and carboxylic acids, formed by reactive oxygen species during plasma discharge [25,26]. Moreover, after plasma treatment, some change can be noted in the characteristic crystalline peaks of PA66 at 930 cm−1 and 1200 cm−1, attributable to the amide axial deformation (C–C=O) and symmetrical angular deformation of out of plane amide III, respectively. Figure 1. FTIR–attenuated total reflectance (ATR) spectra of polyamide 6,6 (PA66) fabric with plasma treatment (solid line) and without plasma treatment (dashed line). 3.2. Reflectance Spectroscopy AgNPs of 20 nm are known to have the highest absorption in the visible region around 420 nm. Thus, this wavelength was considered for AgNP detection (Figure 2). The PA66 samples obtained by spray and exhaustion methods at different temperatures were analyzed before and after five washing cycles. For the unwashed samples, the spray deposition method showed the lowest AgNP deposition rate with no significant difference between the untreated and plasma-treated samples (Figure 2a). On the other hand, the exhaustion methods demonstrated superior AgNP loading, especially at 100 C, well above the glass transition temperature of PA66. At 70 C and 100 C, only a slight difference 400900140019002400290034003900 Trasmittance (A.U.) Wavenumbers (cm -1 ) Untreated Plasma treated Figure 1. FTIR–attenuated total reflectance (ATR) spectra of polyamide 6,6 (PA66) fabric with plasma treatment (solid line) and without plasma treatment (dashed line). 3.2. Reflectance Spectroscopy AgNPs of 20 nm are known to have the highest absorption in the visible region around 420 nm. Thus, this wavelength was considered for AgNP detection (Figure 2). The PA66 samples obtained by spray and exhaustion methods at different temperatures were analyzed before and after five washing cycles. For the unwashed samples, the spray deposition method showed the lowest AgNP deposition rate with no significant difference between the untreated and plasma-treated samples (Figure 2a). On the other hand, the exhaustion methods demonstrated superior AgNP loading, especially at 100 ◦ C,
Coatings 2019,9, 581 5 of 14 well above the glass transition temperature of PA66. At 70 ◦ C and 100 ◦ C, only a slight difference between samples with and without DBD plasma treatment was observed. The deposition method by exhaustion at 30 ◦ C of the untreated sample showed, as expected, a very low deposition yield, exhibiting a high value of reflectance (75%). However, after DBD plasma treatment, the reflectance value was comparable with the values obtained at 70 ◦ C and 100 ◦ C with and without plasma treatment. The washing fastness of the AgNPs deposited onto the PA66 samples was evaluated after five consecutive cycles of industrial laundries at 75 ◦ C for 15 min (Figure 2b). Comparing the different AgNP deposition methods and plasma treatment effects after laundering, a superior washing resistance of the loaded AgNPs in the plasma-treated samples was observed. Also in this case, the best result was observed for the exhaustion method at 30 ◦C on the DBD plasma-treated samples. Coatings 2019, 9, x FOR PEER REVIEW 5 of 14 between samples with and without DBD plasma treatment was observed. The deposition method by exhaustion at 30 C of the untreated sample showed, as expected, a very low deposition yield, exhibiting a high value of reflectance (75%). However, after DBD plasma treatment, the reflectance value was comparable with the values obtained at 70 C and 100 C with and without plasma treatment. The washing fastness of the AgNPs deposited onto the PA66 samples was evaluated after five consecutive cycles of industrial laundries at 75 C for 15 min (Figure 2b). Comparing the different AgNP deposition methods and plasma treatment effects after laundering, a superior washing resistance of the loaded AgNPs in the plasma-treated samples was observed. Also in this case, the best result was observed for the exhaustion method at 30 C on the DBD plasma-treated samples. (a) (b) Figure 2. Diffuse reflectance (%) at 420 nm for the untreated and dielectric barrier discharge (DBD) plasma-treated samples with poly(N-vinylpyrrolidone)-coated silver nanoparticles (PVP–AgNPs) before washing (a) and after five washing cycles (b). 3.3. SEM and EDS Analysis SEM images were captured to evaluate the deposition efficiency and distribution of the AgNPs on the untreated and DBD plasma-treated PA66 samples obtained with the two different deposition methods (Figure 3). DBD plasma-treated samples displayed an increased surface roughness, as reported previously [26]. Considering the different deposition methods, the exhaustion samples presented a higher AgNP concentration when compared with the spray samples. The exhaustion methods showed superior AgNP deposition when the temperature was raised from 30 to 70 C, but more agglomeration was also observed. (a) (b) Figure 2. Diffuse reflectance (%) at 420 nm for the untreated and dielectric barrier discharge (DBD) plasma-treated samples with poly(N-vinylpyrrolidone)-coated silver nanoparticles (PVP–AgNPs) before washing (a) and after five washing cycles (b). 3.3. SEM and EDS Analysis SEM images were captured to evaluate the deposition efficiency and distribution of the AgNPs on the untreated and DBD plasma-treated PA66 samples obtained with the two different deposition methods (Figure 3). DBD plasma-treated samples displayed an increased surface roughness, as reported previously [ 26 ]. Considering the different deposition methods, the exhaustion samples presented a higher AgNP concentration when compared with the spray samples. The exhaustion methods showed superior AgNP deposition when the temperature was raised from 30 to 70 ◦ C, but more agglomeration was also observed. Coatings 2019, 9, x FOR PEER REVIEW 5 of 14 between samples with and without DBD plasma treatment was observed. The deposition method by exhaustion at 30 C of the untreated sample showed, as expected, a very low deposition yield, exhibiting a high value of reflectance (75%). However, after DBD plasma treatment, the reflectance value was comparable with the values obtained at 70 C and 100 C with and without plasma treatment. The washing fastness of the AgNPs deposited onto the PA66 samples was evaluated after five consecutive cycles of industrial laundries at 75 C for 15 min (Figure 2b). Comparing the different AgNP deposition methods and plasma treatment effects after laundering, a superior washing resistance of the loaded AgNPs in the plasma-treated samples was observed. Also in this case, the best result was observed for the exhaustion method at 30 C on the DBD plasma-treated samples. (a) (b) Figure 2. Diffuse reflectance (%) at 420 nm for the untreated and dielectric barrier discharge (DBD) plasma-treated samples with poly(N-vinylpyrrolidone)-coated silver nanoparticles (PVP–AgNPs) before washing (a) and after five washing cycles (b). 3.3. SEM and EDS Analysis SEM images were captured to evaluate the deposition efficiency and distribution of the AgNPs on the untreated and DBD plasma-treated PA66 samples obtained with the two different deposition methods (Figure 3). DBD plasma-treated samples displayed an increased surface roughness, as reported previously [26]. Considering the different deposition methods, the exhaustion samples presented a higher AgNP concentration when compared with the spray samples. The exhaustion methods showed superior AgNP deposition when the temperature was raised from 30 to 70 C, but more agglomeration was also observed. (a) (b) Figure 3. Cont.
Coatings 2019,9, 581 6 of 14 Coatings 2019, 9, x FOR PEER REVIEW 6 of 14 (c) (d) (e) (f) (g) (h) Figure 3. SEM images of untreated (a, c, e and g) and DBD plasma-treated (b, d, f and h) PA66 samples with AgNPs deposited by spray (a and b), exhaustion at 30 °C (c and d), exhaustion at 70 °C (e and f) and exhaustion at 100 °C (g and h), with a magnification of 5000×. Peaks associated with silver were detected on the surface of both spray and exhaustion samples by EDS analysis (Figure 4). The characteristic peaks of silver (AgLI, AgLa, AgLb and AgLg) were observed in the EDS spectrum between 2.5 and 3.4 KeV. An Au peak, derived from the coating process prior to analysis, was also observed. Carbon and oxygen peaks were also detected, corresponding to the PA66 atomic components. Figure 3. SEM images of untreated ( a , c , e , g ) and DBD plasma-treated ( b , d , f , h ) PA66 samples with AgNPs deposited by spray ( a , b ), exhaustion at 30 ◦ C ( c , d ), exhaustion at 70 ◦ C ( e , f ) and exhaustion at 100 ◦C (g,h), with a magnification of 5000×. Peaks associated with silver were detected on the surface of both spray and exhaustion samples by EDS analysis (Figure 4). The characteristic peaks of silver (AgLI, AgLa, AgLb and AgLg) were observed in the EDS spectrum between 2.5 and 3.4 KeV. An Au peak, derived from the coating process prior to analysis, was also observed. Carbon and oxygen peaks were also detected, corresponding to the PA66 atomic components.
Coatings 2019,9, 581 7 of 14 Coatings 2019, 9, x FOR PEER REVIEW 7 of 14 (a) (b) Figure 4. EDS analysis of the spray (a) and exhaustion at 30 °C (b) deposition methods for the PA66 samples with DBD plasma treatment. 3.4. XPS Analysis The results from the XPS spectra analysis were used to calculate the relative chemical composition and atomic ratios (O/C and N/C) of the untreated and DBD plasma-treated samples with AgNPs deposited by spray and exhaustion (at 30 C and 70 C) (Table 1). The relative chemical compositions showed an increase in oxygen content, higher atomic O/C and lower N/C ratios compared to the control samples without DBD plasma treatment. Silver was only detected in the DBD plasma-treated samples in exhaustion conditions (1.5 at % and 0.3 at % for the samples treated at 30 °C and 70 °C, respectively). Chemical bonding information was achieved by deconvolution of C1s, N1s and O1s for all the tested samples and Ag3d for the DBD plasma-treated samples obtained by exhaustion at 30 °C and 70 °C (Table 2 and Figure 5). The C1s spectra showed three peaks between 285.0 and 288.0 eV. A major peak appearing at 285.0 eV was attributed to C–C and C–H bonds. A peak assigned to C–N bonds emerged at 286.1 eV for the untreated samples and 286.4 eV for the plasma-treated samples. A C1s peak attributed to O=C–N also presented a positive shift in binding energy between samples with and without plasma treatment, but only for the exhaustion samples. The untreated and DBD plasma-treated spray samples, as well as the untreated exhaustion samples, showed an O=C–N peak at 287.8 eV. In the exhaustion DBD plasma-treated samples, the same peak appeared at 288.0 eV. The O1s high resolution spectra presented two peaks, attributed to O=C and O–C. The O=C bonds emerged at 531.2 eV for the untreated samples and 531.4 eV for the plasma0.0 1.0 2.0 3.0 4.0 5.0 Binding energy (KeV) O Au Ag Ag Ag Ag Au C 0.0 1.0 2.0 3.0 4.0 5.0 Binding energy (KeV) O Au Ag Ag Ag Ag C Figure 4. EDS analysis of the spray ( a ) and exhaustion at 30 ◦ C ( b ) deposition methods for the PA66 samples with DBD plasma treatment. 3.4. XPS Analysis The results from the XPS spectra analysis were used to calculate the relative chemical composition and atomic ratios (O/C and N/C) of the untreated and DBD plasma-treated samples with AgNPs deposited by spray and exhaustion (at 30 ◦ C and 70 ◦ C) (Table 1). The relative chemical compositions showed an increase in oxygen content, higher atomic O/C and lower N/C ratios compared to the control samples without DBD plasma treatment. Silver was only detected in the DBD plasma-treated samples in exhaustion conditions (1.5 at % and 0.3 at % for the samples treated at 30 ◦ C and 70 ◦ C, respectively). Chemical bonding information was achieved by deconvolution of C1s, N1sand O1sfor all the tested samples and Ag3d for the DBD plasma-treated samples obtained by exhaustion at 30 ◦ C and 70 ◦ C (Table 2and Figure 5). The C1sspectra showed three peaks between 285.0 and 288.0 eV. A major peak appearing at 285.0 eV was attributed to C–C and C–H bonds. A peak assigned to C–N bonds emerged at 286.1 eV for the untreated samples and 286.4 eV for the plasma-treated samples. A C1speak attributed to O=C–N also presented a positive shift in binding energy between samples with and without plasma treatment, but only for the exhaustion samples. The untreated and DBD plasma-treated spray samples, as well as the untreated exhaustion samples, showed an O=C–N peak at 287.8 eV. In the exhaustion DBD plasma-treated samples, the same peak appeared at 288.0 eV. The O1s
Coatings 2019,9, 581 8 of 14 high resolution spectra presented two peaks, attributed to O=C and O–C. The O=C bonds emerged at 531.2 eV for the untreated samples and 531.4 eV for the plasma-treated samples, while the O–C bonds emerged at 532.9 eV for all the samples [ 27 ]. The N1s spectra showed two peaks at 399.7 and 401.6 eV, which were attributed to O=C–N due to the asymmetrical bonds dependent on the silver content [ 26 ]. The results of the Ag3d deconvolution analysis showed two peaks at 367.8 and 374.6 eV. Table 1. Relative chemical compositions and atomic ratios of untreated and DBD plasma-treated PA66 fabrics with AgNPs deposited with spray and exhaustion at 30 ◦C and 70 ◦C methods. Samples C (at %) O (at %) N (at %) Ag (at %) O/C Ratio N/C Ratio Spray 80.5 11.0 8.5 ND 0.14 0.11 Spray DBD 79.5 13.0 7.5 ND 0.16 0.09 Ex. 30 77.9 11.8 10.3 ND 0.15 0.13 Ex. 30 DBD 77.0 12.5 9.0 1.5 0.16 0.12 Ex. 70 80.1 11.0 8.9 ND 0.14 0.11 Ex. 70 DBD 79.9 11.6 8.2 0.3 0.15 0.10 Table 2. Results of the deconvolution analysis of the C1s, N1s, O1sand Ag3dpeaks for the untreated and DBD plasma-treated PA66 fabrics with AgNPs deposited with spray and exhaustion at 30 ◦ C and 70 ◦C methods. Reported binding energies have an associated error of ±0.1 eV. Samples Ag3dC1sO1sN1s 367.8 eV 374.6 eV 285.0 eV 286.1 eV 286.4 eV 287.8 eV 288.0 eV 531.2 eV 531.4 eV 532.9 eV 399.7 eV 401.6 eV Spray No DBD – – 71.5 13.4 – 15.0 – 74.3 – 25.7 95.6 4.4 Spray DBD – – 67.6 – 16.9 15.5 – – 55.9 44.1 91.4 8.6 Ex. 30 No DBD – – 70.0 15.1 – 14.9 – 73.6 – 26.3 93.3 6.7 Ex. 30 DBD 52.2 47.8 67.2 – 16.5 – 16.3 – 71.4 28.6 93.4 6.6 Ex. 70 No DBD – – 71.4 13.5 – 15.1 – 73.9 – 26.1 88.9 11.1 Ex. 70 DBD 57.7 42.3 68.9 – 15.4 – 15.7 – 71.7 28.3 89.5 10.5 Coatings 2019, 9, x FOR PEER REVIEW 8 of 14 treated samples, while the O–C bonds emerged at 532.9 eV for all the samples [27]. The N1s spectra showed two peaks at 399.7 and 401.6 eV, which were attributed to O=C–N due to the asymmetrical bonds dependent on the silver content [26]. The results of the Ag3d deconvolution analysis showed two peaks at 367.8 and 374.6 eV. Table 1. Relative chemical compositions and atomic ratios of untreated and DBD plasma-treated PA66 fabrics with AgNPs deposited with spray and exhaustion at 30 C and 70 C methods. Samples C (at %) O (at %) N (at %) Ag (at %) O/C ratio N/C ratio Spray 80.5 11.0 8.5 ND 0.14 0.11 Spray DBD 79.5 13.0 7.5 ND 0.16 0.09 Ex. 30 77.9 11.8 10.3 ND 0.15 0.13 Ex. 30 DBD 77.0 12.5 9.0 1.5 0.16 0.12 Ex. 70 80.1 11.0 8.9 ND 0.14 0.11 Ex. 70 DBD 79.9 11.6 8.2 0.3 0.15 0.10 Table 2. Results of the deconvolution analysis of the C1s, N1s, O1s and Ag3d peaks for the untreated and DBD plasma-treated PA66 fabrics with AgNPs deposited with spray and exhaustion at 30 C and 70 C methods. Reported binding energies have an associated error of ±0.1 eV. Samples Ag3d C1s O1s N1s 367.8 eV 374.6 eV 285.0 eV 286.1 eV 286.4 eV 287.8 eV 288.0 eV 531.2 eV 531.4 eV 532.9 eV 399.7 eV 401.6 eV Spray No DBD – – 71.5 13.4 – 15.0 – 74.3 – 25.7 95.6 4.4 Spray DBD – – 67.6 – 16.9 15.5 – – 55.9 44.1 91.4 8.6 Ex. 30 No DBD – – 70.0 15.1 – 14.9 – 73.6 – 26.3 93.3 6.7 Ex. 30 DBD 52.2 47.8 67.2 – 16.5 – 16.3 – 71.4 28.6 93.4 6.6 Ex. 70 No DBD – – 71.4 13.5 – 15.1 – 73.9 – 26.1 88.9 11.1 Ex. 70 DBD 57.7 42.3 68.9 – 15.4 – 15.7 – 71.7 28.3 89.5 10.5 Figure 5. High-resolution deconvoluted XPS spectra with relative areas of the Ag3d, C1s, O1sand N1s binding energy regions of untreated and plasma-treated PA66 fibers surface with AgNPs deposited with the exhaustion method at 30 ◦C.
Coatings 2019,9, 581 9 of 14 3.5. Antibacterial Activity Quantitative analysis of antibacterial efficiency of PA66 samples with a low concentration of AgNPs was performed against Gram-positive S. aureus and Gram-negative E. coli bacteria (Figure 6). Generally, the antibacterial efficacy toward E. coli was higher than toward S. aureus. For S. aureus, the DBD plasma-treated samples always presented an improved antibacterial performance. The exhaustion methods displayed higher antimicrobial activity than the spray method. The best performance was achieved by the exhaustion at 30 ◦ C method with DBD plasma treatment. This sample represented a 99.99% reduction (4 log reduction), with an effective antimicrobial effect. The spray method displayed only weak antibacterial activity for E. coli, while samples obtained by the exhaustion method showed complete inhibition (5 log reduction) for both untreated and DBD plasma-treated samples. In order to confirm the superior immobilization ability of the AgNPs on the plasma-treated samples, the samples were tested for antimicrobial activity after five washing cycles (data not shown). The results showed that the plasma-treated sample obtained from the exhaustion at 30 ◦ C method was able to maintain reasonable antimicrobial activity despite the very low Ag concentration on the fabric surface (E. coli log reduction 1.94 ± 0.01 and S. aureus log reduction 0.34 ± 0.02). All other samples (spray and exhaustion at 70 and 100 ◦C with and without plasma treatment) did not display antimicrobial activity after washing. Coatings 2019, 9, x FOR PEER REVIEW 9 of 14 Figure 5. High-resolution deconvoluted XPS spectra with relative areas of the Ag3d, C1s, O1s and N1s binding energy regions of untreated and plasma-treated PA66 fibers surface with AgNPs deposited with the exhaustion method at 30 °C. 3.5. Antibacterial Activity Quantitative analysis of antibacterial efficiency of PA66 samples with a low concentration of AgNPs was performed against Gram-positive S. aureus and Gram-negative E. coli bacteria (Figure 6). Generally, the antibacterial efficacy toward E. coli was higher than toward S. aureus. For S. aureus, the DBD plasma-treated samples always presented an improved antibacterial performance. The exhaustion methods displayed higher antimicrobial activity than the spray method. The best performance was achieved by the exhaustion at 30 °C method with DBD plasma treatment. This sample represented a 99.99% reduction (4 log reduction), with an effective antimicrobial effect. The spray method displayed only weak antibacterial activity for E. coli, while samples obtained by the exhaustion method showed complete inhibition (5 log reduction) for both untreated and DBD plasma-treated samples. In order to confirm the superior immobilization ability of the AgNPs on the plasma-treated samples, the samples were tested for antimicrobial activity after five washing cycles (data not shown). The results showed that the plasma-treated sample obtained from the exhaustion at 30 °C method was able to maintain reasonable antimicrobial activity despite the very low Ag concentration on the fabric surface (E. coli log reduction 1.94 0.01 and S. aureus log reduction 0.34 0.02). All other samples (spray and exhaustion at 70 and 100 °C with and without plasma treatment) did not display antimicrobial activity after washing. (a) (b) Figure 6. S. aureus (a) and E. coli (b) reduction of the untreated and DBD-plasma-treated samples with PVP–AgNPs after 24 h of contact. 4. Discussion In order to improve AgNP adhesion onto a PA66 fabric surface, DBD plasma treatment was performed. The plasma treatment successfully modified the surface energy of the samples, as proved by the wettability results. The contact angle decreased from 90° ± 1.6° to 40° ± 2.5° after 5 passages and it was not detectable after 10 passages. DBD plasma discharge using atmospheric air and working with energies lower than 10 eV could easily cause the breaking of the weakest bond in the polymer chain of PA66—the C–N bond—thereby creating new carbonyl groups, as proved in the FTIR spectra in Figure 1 [28]. Additionally, modification of the crystalline peaks of PA66 suggested alterations in its crystallinity and on the aliphatic polyamide structure [29]. No new peaks appeared in the FTIR spectra after deposition of AgNPs, suggesting the non-covalent nature of the interaction between AgNPs and the polyamide surface species. FTIR is not able to detect ionic, hydrogen (only detected as a shift or broadening of peaks), Van der Waals or electrostatic forces, which are forces that can significantly influence the physico-chemical adhesion of the silver nanoparticles. Moreover, a highdepth FTIR probe is not compatible with surface analyses. Thus, X-ray photoelectric and diffuse Figure 6. S. aureus ( a ) and E. coli ( b ) reduction of the untreated and DBD-plasma-treated samples with PVP–AgNPs after 24 h of contact. 4. Discussion In order to improve AgNP adhesion onto a PA66 fabric surface, DBD plasma treatment was performed. The plasma treatment successfully modified the surface energy of the samples, as proved by the wettability results. The contact angle decreased from 90 ◦± 1.6 ◦ to 40 ◦± 2.5 ◦ after 5 passages and it was not detectable after 10 passages. DBD plasma discharge using atmospheric air and working with energies lower than 10 eV could easily cause the breaking of the weakest bond in the polymer chain of PA66—the C–N bond—thereby creating new carbonyl groups, as proved in the FTIR spectra in Figure 1[ 28 ]. Additionally, modification of the crystalline peaks of PA66 suggested alterations in its crystallinity and on the aliphatic polyamide structure [ 29 ]. No new peaks appeared in the FTIR spectra after deposition of AgNPs, suggesting the non-covalent nature of the interaction between AgNPs and the polyamide surface species. FTIR is not able to detect ionic, hydrogen (only detected as a shift or broadening of peaks), Van der Waals or electrostatic forces, which are forces that can significantly influence the physico-chemical adhesion of the silver nanoparticles. Moreover, a high-depth FTIR probe is not compatible with surface analyses. Thus, X-ray photoelectric and diffuse reflectance spectroscopy were employed to further investigate the AgNP deposition on the fabric surface. Since AgNPs are able to absorb light in the visible region, diffuse reflectance spectroscopy measurements were performed on untreated and DBD plasma-treated PA66 samples in order to compare the relative amount of AgNPs on the fabric surface [ 7 , 30 ]. As a consequence of the low nanoparticle concentration used in this work, the main drawback of the spray method was that