scieee AI-readable full text Open interactive document viewer

Applying Renewable Energy Technologies in an Integrated Optimization Method for Residential Building’s Design

Aparicio Ruiz, Pablo; Guadix Martín, José; Barbadilla Martín, Elena; Muñuzuri, Jesús

Abstract

Designing a Zero Energy Building (ZEB) requires an optimal choice of the materials of a building envelope. Different material properties and window areas could be selected to generate a set of possibilities of the design of a building, being the demand defined by its thermal characteristics. The energy demand of a building could be produced with renewable systems such as photovoltaic. Moreover, the HVAC (Heating, Ventilation, and Air Conditioning) systems could be selected considering the system cost. The present methodology focuses on finding a balance between investment and low energy consumption for a building, based on an integrated optimization method. Such methodology applies a Tabu search algorithm and a simplified model to select the passive design. Afterwards, active elements of the design, as photovoltaic systems, are selected. Therefore, the methodology faces the problem of estimating the annual energy demand and the life cycle cost. The goal is the design of a building with a large amount of energy generated by renewable energy, to have a ZEB, and in the worst case, a nearly Zero Energy Building (nZEB). This methodology reduces investment, reduces the energy demand and selects the best construction materials, renewable energy, and air conditioning system. The present paper analyzes a set of case studies considering different climatic zones in Spain. The results conclude that the methodology could help builders in the design stage, to find a new design that allows a ZEB with the optimal life cycle cost.

Full text

applied sciences Article Applying Renewable Energy Technologies in an Integrated Optimization Method for Residential Building’s Design Pablo Aparicio-Ruiz , JoséGuadix-Martín *, Elena Barbadilla-Martín and Jesús Muñuzuri-Sanz Grupo de Ingeniería de Organización, Escuela Técnica Superior de Ingeniería, Universidad de Sevilla, Camino de los Descubrimientos S/N, 41092 Seville, Spain; [email protected] (P.A.-R.); [email protected] (E.B.-M.); [email protected] (J.M.-S.) *Correspondence: [email protected]; Tel.: +34-954-448-7389 Received: 28 December 2018; Accepted: 23 January 2019; Published: 29 January 2019   Abstract: Designing a Zero Energy Building (ZEB) requires an optimal choice of the materials of a building envelope. Different material properties and window areas could be selected to generate a set of possibilities of the design of a building, being the demand defined by its thermal characteristics. The energy demand of a building could be produced with renewable systems such as photovoltaic. Moreover, the HVAC (Heating, Ventilation, and Air Conditioning) systems could be selected considering the system cost. The present methodology focuses on finding a balance between investment and low energy consumption for a building, based on an integrated optimization method. Such methodology applies a Tabu search algorithm and a simplified model to select the passive design. Afterwards, active elements of the design, as photovoltaic systems, are selected. Therefore, the methodology faces the problem of estimating the annual energy demand and the life cycle cost. The goal is the design of a building with a large amount of energy generated by renewable energy, to have a ZEB, and in the worst case, a nearly Zero Energy Building (nZEB). This methodology reduces investment, reduces the energy demand and selects the best construction materials, renewable energy, and air conditioning system. The present paper analyzes a set of case studies considering different climatic zones in Spain. The results conclude that the methodology could help builders in the design stage, to find a new design that allows a ZEB with the optimal life cycle cost. Keywords: algorithm optimization; photovoltaic; renewable energy; LCC 1. Background In the coming years, all European countries should comply with the objectives of the Energy Efficiency Directive for Buildings (2010/31/EC) [ 1 ]. This directive establishes a set of measures to face the challenge of the so-called almost zero energy consumption buildings, nZEB (nearly Zero Energy Buildings) by 2020. In the construction sector, this directive is a means of transforming the design, construction, and management procedures towards greater energy efficiency in buildings and cities. The challenge affects both architects and the rest of the agents (promoters, builders, manufacturers of materials, systems, and equipment), that will have to meet the regulatory requirements. The main priority of a nZEB is the energy efficiency. In the buildings, from the conception of design to the exploitation, the objective of actively reducing the energy consumption of the final building. Although the objective is reducing energy demand, a second priority focuses on the remaining energy needs and renewable energies. Therefore, a nZEB will not only imply an optimized design and construction, but also the exploitation of energy resources in the most efficient way. Appl. Sci. 2019,9, 453; doi:10.3390/app9030453 www.mdpi.com/journal/applsci Appl. Sci. 2019,9, 453 2 of 15 The present paper explores a methodology to design a nZEB building, by choosing design elements in two steps (Figure 1). Firstly, the selection of passive elements, and secondly the selection of active elements with a system of photovoltaic panels to generate the energy required by such building. To achieve a ZEB (Zero Energy Building), the Building Integrated Photovoltaic (BIPV) systems used to generate electricity can play an important role [ 2 ]. A comprehensive review of the current state of the art in the area of the BIPV technology is shown in [ 3 ]. Moreover, some studies have verified the validity of BIPV systems for the challenge of Zero Energy Buildings [4]. Appl. Sci. 2018, 8, x FOR PEER REVIEW 2 of 14 remaining energy needs and renewable energies. Therefore, a nZEB will not only imply an optimized design and construction, but also the exploitation of energy resources in the most efficient way. The present paper explores a methodology to design a nZEB building, by choosing design elements in two steps (Figure 1). Firstly, the selection of passive elements, and secondly the selection of active elements with a system of photovoltaic panels to generate the energy required by such building. To achieve a ZEB (Zero Energy Building), the Building Integrated Photovoltaic (BIPV) systems used to generate electricity can play an important role [2]. A comprehensive review of the current state of the art in the area of the BIPV technology is shown in [3]. Moreover, some studies have verified the validity of BIPV systems for the challenge of Zero Energy Buildings [4]. Figure 1. From conventional buildings to ZEB. HVAC: Heating, Ventilation, and Air Conditioning; nZEB: nearly Zero Energy Buildings In Ferrara et al. [5], it is demonstrated that the zero energy objective is technically feasible through the optimal interaction of all the building design variables, that can be studied in detail through advanced simulation and optimization models. In [6], a procedure for cost optimal and nZEB energy performance levels calculations is defined: the selection of the reference building, the definition of construction concepts based on building envelope optimization, the specification of building technical systems, the energy simulations for specified construction concepts (in this paper it is not a simulation, and it is based on a simplified model), economic calculations, and sensitivity analyses. The main goal of the present paper is showing a methodology to achieve the design of a nZEB, including passive elements and active elements, particularly, photovoltaic, and HVAC (Heating, Ventilation, and Air Conditioning) systems. The Energy Performance of Buildings Directive [7] lists the main end-uses to be included in a building, such as heating, domestic hot water, refrigeration, ventilation, and lighting, being heating and cooling the elements with the highest levels of energy consumption. To achieve an nZEB, finding out the optimal combination for a building design is necessary. To define the design elements, it is also important to consider the location and the climatic conditions. The climatic conditions and the elements define the energy demand for the heating and cooling period, based on the thermal characteristics of the passive elements. After the passive elements, active elements (as the application of photovoltaic panels) produce the necessary energy, and elements such as HVAC systems provide the required comfort level. Moreover, according to the efficiency of the passive elements and the active systems, a life cycle cost (LCC) could be defined. STEP 1: Materials and Elements STEP 2: Renewable Ener gy + HVAC s y stems Passive Design Active Design Conventional Building Energy needs reduction Low-energy Building ZEB or nZEB: Low-energy Building + Renewable Energy+ Efficient HVAC System HVAC energy savings and Photovoltaic Conventional HVAC + Conventional Energy Conventional HVAC + Conventional Energy Figure 1. From conventional buildings to ZEB. HVAC: Heating, Ventilation, and Air Conditioning; nZEB: nearly Zero Energy Buildings. In Ferrara et al. [ 5 ], it is demonstrated that the zero energy objective is technically feasible through the optimal interaction of all the building design variables, that can be studied in detail through advanced simulation and optimization models. In [ 6 ], a procedure for cost optimal and nZEB energy performance levels calculations is defined: the selection of the reference building, the definition of construction concepts based on building envelope optimization, the specification of building technical systems, the energy simulations for specified construction concepts (in this paper it is not a simulation, and it is based on a simplified model), economic calculations, and sensitivity analyses. The main goal of the present paper is showing a methodology to achieve the design of a nZEB, including passive elements and active elements, particularly, photovoltaic, and HVAC (Heating, Ventilation, and Air Conditioning) systems. The Energy Performance of Buildings Directive [ 7 ] lists the main end-uses to be included in a building, such as heating, domestic hot water, refrigeration, ventilation, and lighting, being heating and cooling the elements with the highest levels of energy consumption. To achieve an nZEB, finding out the optimal combination for a building design is necessary. To define the design elements, it is also important to consider the location and the climatic conditions. The climatic conditions and the elements define the energy demand for the heating and cooling period, based on the thermal characteristics of the passive elements. After the passive elements, active elements (as the application of photovoltaic panels) produce the necessary energy, and elements such as HVAC systems provide the required comfort level. Moreover, according to the efficiency of the passive elements and the active systems, a life cycle cost (LCC) could be defined. In [ 8 ], a recent review about the optimization and cost-optimal methodologies applied in the low-energy building design and environmental considerations is shown. In 2017, Loukaidou et al. Appl. Sci. 2019,9, 453 3 of 15 defined the determination of optimal cost solutions towards nearly zero-energy buildings as a serious challenge [ 9 ]. A review on simulation-based optimization methods applied to building performance analysis is shown in Nguyen et al. [ 10 ]. The previous research shows the increasing trend regarding the number of optimization studies in the building area, the classification of building optimization problems and the mostly-used algorithms. The present paper is based on an approach of a previous study [ 11 ], focused on the minimization of building’s thermal loads through the employment of passive elements, and on a second study [ 12 ] focused on the implementation of efficient HVAC systems, as low temperature surface embedded heating and cooling systems. In [ 12 ], the HVAC system with different types of energy (Electric Heat Pump—EHP, Gasoil—G, biomass boiler—BB, wood pellets boiler—WPB, natural gas—NG, and woodchips boiler—WCB) is selected. Particularly, the present paper is focused on photovoltaic systems and the selection of HVAC systems based on electricity. If the adoption of renewable energy generation technologies (photovoltaics in this case) was not enough, the system would use energy from the conventional power networks. The paper shows 12 case studies for different climatic zones in Spain. The solution obtained is based on a methodology in order to optimize the life cycle cost, minimizing the building’s thermal loads, and to select the photovoltaic technology and the HVAC system. The paper is structured as follows. Section 1introduces the methodology of passive optimization and explains the methodology proposed for its application with photovoltaic technology. Section 2exposes the case studies. Section 3 shows the main results obtained and Section 4highlights the main conclusions. 2. Methodology The process to obtain a ZEB or a nZEB requires the following steps: Firstly, the design of a building, according to the Spanish technical building code. Secondly, the optimization of the passive elements. Thirdly, the application of renewable energies and the choice of HVAC systems, for which it is necessary to redefine the life cycle cost. These aspects will be analyzed below. 2.1. Human Design Model The first step is the human (user) design; the user builds a reference model, the initial design. The design defines a set of building specifications: the type of building, the location, the climate zone, the orientation, and a first decision and selection of elements or materials (floor, walls, windows, etc.). This step defines a fixed set of independent variables related to the building, which is generally accepted in the Spanish technical building code. 2.2. Passive Optimization The methodology proposed is focused on the minimization of a building’s energy demand during the design process. The decision is made through the employment of passive elements. To evaluate and study the design decision, the tabu algorithm analyzes solutions and alternatives. In papers [8,13,14] different algorithms and computational optimization methods applied to obtain ZEBs or nZEBs are shown. The methodology applied in passive elements is presented in [11]. The present methodology was validated by a detailed software tool (LIDER-CALENER). This software is used as a basic procedure for building energy certification according to the Spanish building regulations. After the human design, a simplified model of analysis was applied. This simplified model calculates the heating and cooling demand. The energy demand was considered and quantified by a simplified model defined by [15]. The annual heating demand (HD) is estimated by Equation (1). Appl. Sci. 2019,9, 453 4 of 15 HD =a·Um ×At V·(height)·HDD·24 1000 +b·Av Aa ·g·ASSE·Is +c ·(ventilation)·ρ·Cp·(height)·HDD·24 3600 +d.(1) The heating demand in kWh/m 2 is based on the climatic zone and the corresponding correlation coefficients (a,b,c,d). The heating months include January–May and October–December. The parameters, variables and data are defined in Table 1. The annual cooling demand (CD) is estimated by Equation (2). CD =a·Um without/roof ×At V·(height)·CDD·24 1000 +b·(Uroof)·Aroof Aa  ·CDD·24 1000 +c·(ventilation)·ρ·Cp·(altura)·CDD·24 3600  +d·(ventilation night)·ρ·Cp·(height)·CDDnight·24 3600 +e ·Av Aa ·g·ASSE·Is +f. (2) The cooling demand in kWh/m 2 is based on the climatic zone and the corresponding correlation coefficients (a,b,c,d,e,f). The cooling months include June–September, which define the corresponding correlation coefficients. The parameters, variables and data are defined in Table 1. Table 1. Parameters, variables and data depending on variables. Type Name Description Climate parameters Locality Geographic location. HDD Heating degree-days in the location and the considered period. CDD Cooling degree-days in the location and the considered period. Is Accumulated global radiation on a vertical surface oriented to the south and during the period considered (kWh/m2). Building parameters Floors Number of building floors. Ai Transfer area of element i. Elements: roof, floors, walls and windows of each orientation. Height Height of the spaces (m). ASSE Solar equivalent south area (dimensionless). It is the relationship between the radiation received by the windows and their corresponding directions, taking into account near and far-shadowing, together with the radiation that they would receive if they were facing south with no shade. G Solar factor through the windows (dimensionless). Ventilation Renovations per hour due to ventilation and/or infiltration. Li Length of thermal bridge i. Aa Conditioned area: floor area ×number of floors. Building variables Avi Percentage of area of the windows, direction i. pi Permeability of the windows, direction i. Ui Thermal transmittance of an element i. Ψi Linear thermal transmittance of thermal bridge i. Dependent values of the building variables At Area of transfer. Um The mean thermal transmittance of the building, calculated from the transmittances of the elements of the envelope, including thermal bridges. At/V A/V ratio, transfer area to volume ratio. Av/Aa Window equivalent south area to conditioned area ratio. Thermal properties PDensity of air (1.2 kg/m3) Cp Specific heat of air at constant pressure (1 kJ/kg·K). Appl. Sci. 2019,9, 453 5 of 15 The cooling and heating demand are used to define the Energy Performance Certificates (EPCs). The EPCs calculation method is very similar in all countries, using the annual energy demand of the building to calculate the energy rating [ 16 ]. For such calculation, it is necessary to be very precise defining the building envelope, materials, thermal bridges, heating and cooling, etc. The methodology proposed seeks the best passive solution, based on the best EPC with the lowest Life Cycle Cost (LCC). The LCC is defined in Equation (3) and contains the cost of investment in materials and construction elements, which depend on the materials selected and their characteristics: the thermal transmittance of the opaque (walls, roofs and floors); thermal transmittance, solar factor and permeability of windows; linear thermal transmittance of thermal bridges; permeability, etc. As the investment has effects on the building demand, it implies that such demand defines the operation cost due to energy consumption for heating and cooling demand of the building studied, and therefore the living cost of consumption and emissions generated by such building. LCC(€)=Investment(€)+Consumptionyear€ year +Costemissions year€ year  ×Annuity(years) where : Investment(€)=n ∑ t=1PriceElement t€ m2·AreaElement tm2 +PriceThermal bridges€ m·LengthThermal bridges(m) Consumptionyear€ year =n ∑ t=1 Consumptiont€ year  Costemissions year€ year =n ∑ t=1 Costemissionst€ year  Annuity(years)=n ∑ t=1 (1+k1)t (1+k)t Consumptionyear€ year  =Demandyear t(kWh/m2year) Per f ormancesystem ·Priceenergy year t(€/kWh). (3) The LCC is a method of economic analysis which solution depends on the forecasting of the relative weights for different optimization criteria: the number of years considered in the study of economic efficiency, the interest rate used to calculate the Net Present Value (NPV) and the cost of energy. In optimization methods, the Energy Efficiency Index (EEI), or sometimes known as Building Energy Index (BEI) [ 17 ], is the most commonly used index as a Key Performance Indicator (KPI) to track and compare performance of energy consumption in buildings. For this reason, this criterion is used in conjunction with the LCC in the methodology proposed. The solution is focused on optimizing the LCC of a building with the lowest EEI, when selecting the material for a building envelope. The Spanish EEI and energy rating labels are defined in González et al. [18]. 2.3. Renewable Energy: Photovoltaics In the present paper, solar energy was selected among other renewable energy resources due to the fact that photovoltaic systems are clean, inexhaustible and eco-friendly. Regarding the passive decision, the first step (the selection of the passive elements) leads to the best EEI with the minimum LCC. The material selected, and their characteristics, define the building demand, Demandyear t(kWh/year) , which could be generated by a solar installation. Let us suppose that in this case it is an autonomous solar photovoltaic installation (that is, it is isolated from the electricity grid). Therefore, a suitable dimension of the energy need is a main goal, as well as an analysis of the economic cost of the installation for it. Appl. Sci. 2019,9, 453 6 of 15 Once the annual demand is defined, it is necessary to calculate the total energy needed to supply such demand (Equation (4)), this is the total energy that has to be produced to supply the building’s HVAC demand. Total energy needed (Ten)=Demand(Wh) per f ormance . (4) Once the available solar radiation is known, that is, the incident solar radiation (which depends on the location of the building) the energy production capacity of solar panels could be known. These values can be obtained through the existing tables with such estimations. Particularly, in this paper the PVGIS software information (Photovoltaic Geographical Information System—European Commission, Joint Research Center) was used, which estimates produced energy with relative accuracy in Europe and Africa [ 19 , 20 ]. To obtain the data of the PVGIS, latitude and longitude are required (failing that, a geolocation could be used), and then the system provides, on a monthly basis, the data from: the optimal inclination angle, the annual irradiation deficit due to shadowing, the irradiation on a horizontal plane, the irradiation on an optimally inclined plane, and the optimal inclination, among other things. This paper uses the estimation based on the photovoltaic potential of an area under consideration. In general, the installation is usually sized for the most unfavorable monthly conditions of insolation, and thus ensures that it covers the demand throughout the year. Once the incident solar radiation is known, it is divided in order to calibrate the modules (1 kW/m 2 ) and the amount of peak sun hours (PSH) is obtained. For practical purposes, in the case studies analyzed in the present paper, this value does not change, but the concept of PSH will be used, since it is the equivalent number of hours that the sun would have to shine at an intensity of 1000 W/m 2 to obtain the total insolation of a day, due to the fact that the intensity of the sun varies throughout the day. PSH(Ten)=Solar radiation kW/m2 1 kW/m2. (5) The methodology proposed determines the selection of the optimal solar panel. For doing this, it is necessary to know each solar panel and its characteristics: the name of the product and the company (both hidden in the paper), the price in € /Wp (per m 2 of solar panel), the type of solar panel, the efficiency of the solar panel, and the power range. Additionally, the weight and the size of the solar panels are also known. In order to calculate the number of modules, Equation (6) defines it as the required energy divided by PSH, the efficiency of the solar panel and the peak power of the module. Number o f solar modules =energy required (PSH·work efficiency·module peak power). (6) After counting the number of solar panels required, the number of panels in m 2 was less than the square meters available on the roof of the building. If the available square meters had exceeded the square meters, the conventional electricity would have had to be used. The performance of the solar panels must take into account the losses due to various reasons: losses caused by possible fouling and/or deterioration of the photovoltaic panels (normally 0.7–0.8). This factor is understood to be the efficiency factor obtained from the manufacturer’s data. For this reason, it will be required to produce more energy than the demand required by the final user. In the methodology proposed, it is assumed that there are no batteries, but that the energy not consumed is delivered to the network and the corresponding energy is received from the network when sufficient energy is not generated. However, if an inverter is required, the system selects the power of the DC/AC inverter depending on the total nominal power of the equipment. Inverter power (W)=Estimated total power (W) Coefficient . (7) Appl. Sci. 2019,9, 453 7 of 15 The optimizer will be responsible for finding the best option to meet the defined demand. 2.4. Active Systems: HVAC HVAC systems in buildings have the purpose to ensure a certain level of thermal comfort, but in general, this objective implies high energy consumption and high cost for the installations. In buildings, the end-use of energy is mainly dedicated for conditioning the spaces, both during winter and summer periods. After the evolution from the conventional design to an efficient envelope, the final step is the choice of an efficient HVAC system in order to achieve an optimal indoor comfort level. In [ 7 ], the application of the HVAC systems is presented, which will be considered for the methodology proposed in this paper. 2.5. Changes in the Life Cycle Cost The life cycle cost of the building for the optimization of the passive elements is shown in Equation (3). However, with the application of renewable energies and HVAC systems, the LCC is modified (Equation (3)), according to the investment shown in Equation (8). Investment(€)=n ∑ t=1PriceElement t€ m2·AreaElement tm2 +PriceThermal bridges€ m·LengthThermal bridges(m) +PriceHVAC Strategy(€)+PricePV€ m2·AreaPV m2+Inverter(€), (8) where the price ( € /m 2 ) and the area (m 2 ) can be replaced by the price of a solar panel and the number of solar panels to be installed. The cost of the HVAC system is also considered in Equation (8). Regarding the energy consumption, the calculation of the initial energy consumption (based on the use of the traditional electricity grid) is reduced to zero, given that the main goal of the methodology proposed is the implantation of 100% of renewable energy from solar panels (Equations (9) and (10)). Therefore, it also leads to reduce the costs of CO2emissions and to reduce the LCC. consumptionFinal Energy =Demand (1−%renewable energy) per f ormance , (9) consumptionPrimary Energy =ratioPrimary Energy·consumptionFinal Energy. (10) Once the methodology is known, in Section 2the case studies will be presented, and in Section 3, the results of applying this methodology in the case studies will be shown. 3. Case Studies The same building, with the same characteristics was analyzed, located in different locations, with 12 climatic zones (A3, A4, B3, B4, C1, C2, C3, C4, D1, D2, D3, E1). These climatic zones are defined in the Spanish scale (Technical Building Code scale [ 21 ], Figure 3 in [ 11 ]) based on the Winter Climate Severity (WCS, five climate zones in winter, designated by the letters A–E) and the Summer Climate Severity (SCS, four zones for the summer, designated by the numbers 1–4) [ 22 ], defining combinations of WCS and SCS indexes different climatic zones. Therefore, the building considered was placed in these different locations with their specific climatic conditions. These locations and climatic zones are shown in Table 2and Figure 2. Appl. Sci. 2019,9, 453 8 of 15 Table 2. Cities of the case studies. Cities Climatic Zones 1 Málaga A3 2 Almería A4 3 Valencia B3 4 Sevilla B4 5 Bilbao C1 6 Barcelona C2 7 Granada C3 8 Cáceres C4 9 Lugo D1 10 Valladolid D2 11 Madrid D3 12 Soria E1 Appl. Sci. 2018, 8, x FOR PEER REVIEW 8 of 14 Cities Climatic Zones 1 Málaga A3 2 Almería A4 3 Valencia B3 4 Sevilla B4 5 Bilbao C1 6 Barcelona C2 7 Granada C3 8 Cáceres C4 9 Lugo D1 10 Valladolid D2 11 Madrid D3 12 Soria E1 Figure 2. Cities located in Spain. 3.1. Human Design Model A residential building was considered for the case studies. Such building was a single-family dwelling consisting on three floors: the basement, the ground floor and the first floor (Figure 3). It has 164.4 m2 conditioned space, the envelope area is 209.9 m2, 62.81 m2 of external walls, and 19.91 m2 of windows. This building has a flat roof, without tall buildings or trees around it. The whole area on the roof would be available for installing solar modules. Figure 2. Cities located in Spain. 3.1. Human Design Model A residential building was considered for the case studies. Such building was a single-family dwelling consisting on three floors: the basement, the ground floor and the first floor (Figure 3). It has 164.4 m 2 conditioned space, the envelope area is 209.9 m 2 , 62.81 m 2 of external walls, and 19.91 m 2 of windows. This building has a flat roof, without tall buildings or trees around it. The whole area on the roof would be available for installing solar modules. Appl. Sci. 2019,9, 453 9 of 15 Appl. Sci. 2018, 8, x FOR PEER REVIEW 9 of 14 Figure 3. Plan of the single-family house. 3.2. Passive Optimization The building designed in Section 2.1. (the initial design) was the same for all locations considered: the walls u-values are 0.49 W/m2K, the windows on the north facade: 5.60 W/m2K uvalue, 0.85 g-value, 50 p-value, on the East façade: 1.4 W/m2K u-value, 0.7 g-value, 9 p-value, on the south facade: 3.30 W/m2K u-value, 0.75 g-value, 50 p-value. Finally, the roof u-value is 0.57 W/m2K, and for the floor the u-value is 0.23 W/m2K. The solution is assuming a 3% interest rate and an increase in energy prices of about 5% for 30-year study. Initially, the heating and cooling demand (Table 3) was calculated based on the type on materials used in the construction, which are defined in the previous paragraph, Table 3. Initial design. Cities 1 2 3 4 5 6 7 8 9 10 11 12 Climatic Zones A3 A4 B3 B4 C1 C2 C3 C4 D1 D2 D3 E1 Heating demand (kWh/m2) 12 9.5 21.8 17.2 48.4 33.1 41.6 34.9 71.5 70.1 51.1 85.8 Cooling demand (kWh/m2) 6.22 0.98 4.29 12.4 0 1.82 3.21 8.12 0 0.5 3.07 0 Heating CO2 emissions (kg/m2) 4.02 3.19 7.34 5.8 16.2 11.1 13.9 11.7 24 23.5 17.1 28.7 Cooling CO2 emissions (kg/m2) 2.05 2.96 1.41 4.12 0 0.6 5.74 2.68 0 0.17 1.01 0 Estimation of life cycle cost (k€) 26.6 24.2 39.1 28.9 57.0 54.0 66.7 60.1 108 106 80.5 129 Energy Efficiency Index (EEI). 0.6 0.6 0.67 0.63 0.84 0.74 0.76 0.72 0.88 0.81 0.81 0.92 Figure 3. Plan of the single-family house. 3.2. Passive Optimization The building designed in Section 2.1 (the initial design) was the same for all locations considered: the walls u-values are 0.49 W/m 2 K, the windows on the north facade: 5.60 W/m 2 K u-value, 0.85 g-value, 50 p-value, on the East façade: 1.4 W/m 2 K u-value, 0.7 g-value, 9 p-value, on the south facade: 3.30 W/m 2 K u-value, 0.75 g-value, 50 p-value. Finally, the roof u-value is 0.57 W/m 2 K, and for the floor the u-value is 0.23 W/m 2 K. The solution is assuming a 3% interest rate and an increase in energy prices of about 5% for 30-year study. Initially, the heating and cooling demand (Table 3) was calculated based on the type on materials used in the construction, which are defined in the previous paragraph, Table 3. Initial design. Cities 1 2 3 4 5 6 7 8 9 10 11 12 Climatic Zones A3 A4 B3 B4 C1 C2 C3 C4 D1 D2 D3 E1 Heating demand (kWh/m2)12 9.5 21.8 17.2 48.4 33.1 41.6 34.9 71.5 70.1 51.1 85.8 Cooling demand (kWh/m2) 6.22 0.98 4.29 12.4 0 1.82 3.21 8.12 0 0.5 3.07 0 Heating CO 2 emissions (kg/m 2 ) 4.02 3.19 7.34 5.8 16.2 11.1 13.9 11.7 24 23.5 17.1 28.7 Cooling CO 2 emissions (kg/m 2 ) 2.05 2.96 1.41 4.12 0 0.6 5.74 2.68 0 0.17 1.01 0 Estimation of life cycle cost (k€) 26.6 24.2 39.1 28.9 57.0 54.0 66.7 60.1 108 106 80.5 129 Energy Efficiency Index (EEI). 0.6 0.6 0.67 0.63 0.84 0.74 0.76 0.72 0.88 0.81 0.81 0.92 Energy rating C C C C C C C C C C C C Currently, the EU carbon price (expressed as CO 2 ) is about 20 € per ton (lower limit) [ 23 ]. On the other hand, the electricity price in Spain is about 0.13 € /kWh (standard with no time restrictions) [ 24 ].