Designing and evaluating a wearable device for affective state level classification using machine learning techniques

Muñoz Saavedra, Luis; Escobar Linero, Elena; Miró Amarante, María Lourdes; Bohórquez Gómez-Millán, María Rocío; Domínguez Morales, Manuel Jesús

Abstract

The emotional or affective state has a direct impact not only on personal life, but also in the field of work, sports, rehabilitation processes, among other fields. In the evolving understanding of emotional theory, it has been theorized that an emotion can be classified according to a two-dimensional model composed of an Arousal value and a Valence value, as well as empirically demonstrating the impact of emotions on physiological variables. This work presents the development of a wearable device for capturing physiological signals, the collection of a dataset (after approval by the ethics committee) in which participants’ emotional states are induced, and the development of an automatic classifier of the emotional state based on neural networks. According to this last point, a 4-phase optimization process is presented in which the physiological sensors are evaluated independently and with multiple variations of the hyperparameters of the neural networks, keeping those that provide the most information, combinations are made between them and the robustness of the final system obtained is evaluated. The results exceed 92% accuracy in all cases, which, compared with previous work, significantly improves the classifiers developed in recent years. The key contributions of this study are detailed as follows: (a) a wearable device designed to collect physiological signals from the user in a non-invasive way is presented, proving that it works properly in a controlled environment; (b) a data-collection protocol is designed to induce emotional states in test subjects using small video clips, demonstrating that the user evokes the feelings that are induced; and (c) a machine learning-based system is developed and optimized to classify the emotional state based on the two-dimensional model of emotion, demonstrating its efficiency and accuracy.

Full text

Expert Systems With Applications 219 (2023) 119577 Available online 20 January 2023 0957-4174/© 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/bync-nd/4.0/). Contents lists available at ScienceDirect Expert Systems With Applications journal homepage: www.elsevier.com/locate/eswa Designing and evaluating a wearable device for affective state level classification using machine learning techniques Luis Muñoz-Saavedraa, Elena Escobar-Linerob, Lourdes Miró-Amarantec, M. Rocío Bohórquezd, Manuel Domínguez-Moralesc,∗ aComputer Engineering, Architecture and Computer Technology department (ATC), Robotics and Technology of Computers Lab (RTC), E.T.S. Ingeniería Informática, Universidad de Sevilla, Avda. Reina Mercedes s/n, Seville, 41012, Spain bBiomedical Engineering, Architecture and Computer Technology department (ATC), Robotics and Technology of Computers Lab (RTC), E.T.S. Ingeniería Informática, Universidad de Sevilla, Avda. Reina Mercedes s/n, Seville, 41012, Spain cComputer Engineering, Architecture and Computer Technology department (ATC), Robotics and Technology of Computers Lab (RTC), Computer Engineering Research Institute (I3US), E.T.S. Ingeniería Informática, Universidad de Sevilla, Avda. Reina Mercedes s/n, Seville, 41012, Spain dPsychologist, Social Psychology department, Faculty of Psychology, Camilo José Cela s/n, Universidad de Sevilla, Seville, 41012, Spain ARTICLE INFO Keywords: Machine learning Emotion Affective state Physiological signal Wearable ABSTRACT The emotional or affective state has a direct impact not only on personal life, but also in the field of work, sports, rehabilitation processes, among other fields. In the evolving understanding of emotional theory, it has been theorized that an emotion can be classified according to a two-dimensional model composed of an Arousal value and a Valence value, as well as empirically demonstrating the impact of emotions on physiological variables. This work presents the development of a wearable device for capturing physiological signals, the collection of a dataset (after approval by the ethics committee) in which participants’ emotional states are induced, and the development of an automatic classifier of the emotional state based on neural networks. According to this last point, a 4-phase optimization process is presented in which the physiological sensors are evaluated independently and with multiple variations of the hyperparameters of the neural networks, keeping those that provide the most information, combinations are made between them and the robustness of the final system obtained is evaluated. The results exceed 92% accuracy in all cases, which, compared with previous work, significantly improves the classifiers developed in recent years. The key contributions of this study are detailed as follows: (a) a wearable device designed to collect physiological signals from the user in a noninvasive way is presented, proving that it works properly in a controlled environment; (b) a data-collection protocol is designed to induce emotional states in test subjects using small video clips, demonstrating that the user evokes the feelings that are induced; and (c) a machine learning-based system is developed and optimized to classify the emotional state based on the two-dimensional model of emotion, demonstrating its efficiency and accuracy. 1. Introduction Affective and emotional states have a direct impact on various aspects of daily life. One of the most affected aspects is work productivity: recent studies have revealed that workers’ psychological states, such as positive attitudes and peace of mind, are associated with productivity at work. DiMaria, Peroni, and Sarracino (2020), Frey and Stutzer (2016) and Tenney, Poole, and Diener (2016) revealed that positive thinkers, i.e., happy and satisfied workers, are more likely to perform well. Studies have also highlighted how an employee’s health and well-being ∗Correspondence to: E.T.S. Ingeniería Informática, Architecture and Computer Technology department (ATC), Avda. Reina Mercedes s/n, Office F0.71, 41012, Seville, Spain. E-mail addresses: [email protected] (L. Muñoz-Saavedra), [email protected] (E. Escobar-Linero), [email protected] (L. Miró-Amarante), [email protected] (M.R. Bohórquez), [email protected] (M. Domínguez-Morales). impact productivity. Neumann and Dul (2010), as well as Ødegaard and Roos (2014), found that healthier employees are more productive. Similarly, there are other areas in which a positive emotional state plays a key role, such as rehabilitation therapies (Hu, Xie, & Li,2013; Te Wierike, van der Sluis, van den Akker-Scheek, Elferink-Gemser, & Visscher,2013;Wiese-Bjornstal, Smith, Shaffer, & Morrey,1998), or sports medicine (Ardern, Kvist, & Webster,2016;Diener & Chan,2011; Howell, Kern, & Lyubomirsky,2007). To combat the adverse effects that a negative emotional state can have, various control systems are implemented that make it possible to know the state of each worker and/or patient. In fact, some https://doi.org/10.1016/j.eswa.2023.119577 Received 22 July 2022; Received in revised form 3 January 2023; Accepted 17 January 2023 Expert Systems With Applications 219 (2023) 119577 2 L. Muñoz-Saavedra et al. organizations have been increasing investment in health and wellnessrelated programs for years (Ton,2014). In any case, these controls usually involve interviews with psychologists who, using classic metrics and surveys such as the Discrete Emotions Questionnaire (Harmon-Jones, Bastian, & Harmon-Jones,2016), determine the patient’s emotional state. However, these checks are not performed with a high cadence and, in most cases, are carried out when an adverse effect is detected (such as a significant reduction in productivity, or an unusually long recovery period for a particular injury). In order to be able to detect any emotional signs that could cause problems in the future, it would be necessary to increase controls (without waiting to detect problems) or to develop a mechanism for automatic detection of the emotional state. For this purpose, multiple studies demonstrate the relationship between emotional state and various physiological parameters, mainly related to the unconscious reactions of the user’s body that can be recorded and studied: facial muscle activity, cardiac activity, skin conductance, brain activity, among others. Regarding mechanisms and/or tools that may help for automatic classification, the Artificial Intelligence (AI) field named ‘‘Machine Learning’’ (ML) has taken advantage in the last years. Some ML-tools like Support Vector Machines (SVM), Random Forest (RF), Logistic Regression (LR) or Neural Networks (NN) are commonly used actually for designing classifiers focused on the detection of diseases and/or anomalous medical states (Ayata, Yaslan, & Kamasak,2020; Biagetti, Crippa, Falaschetti, Tanoni, & Turchetti,2018;Kwon, Shin, & Kim,2018;Santamaria-Granados, Munoz-Organero, Ramirez-Gonzalez, Abdulhay, & Arunkumar,2018). In multiple works, classifiers based on Machine Learning (ML) have been developed by this research group for anomaly detection using activity sensors (Domínguez-Morales, Luna-Perejón, Miró-Amarante, Hernández-Velázquez, & Sevillano-Ramos,2019; Escobar-Linero, Domínguez-Morales, & Sevillano,2022;Luna-Perejón, Domínguez-Morales, & Civit-Balcells,2019;Luna-Perejón, Domínguez- Morales, Gutiérrez-Galán, & Civit-Balcells,2020;Luna-Perejón, Muñoz- Saavedra, Civit-Masot, Civit, & Domínguez-Morales,2021, or to detect diseases in medical images (Civit-Masot, Domínguez-Morales, Vicente- Díaz & Civit,2020;Civit-Masot et al.,2021;Civit-Masot, Luna-Perejón, Domínguez Morales & Civit,2020). Also, in a previous work, this team has even achieved acceptable emotional state classification results using a public dataset (Muñoz-Saavedra et al.,2020). The main objectives of this work are the following: (a) designing and implementing a wearable device in order to capture the physiological data of the user, based on a previous work developed by this research group (Muñoz-Saavedra et al.,2020); (b) designing and testing a data collecting protocol from voluntary participants while inducing emotional states using audiovisual information; and (c) designing, implementing, optimizing and evaluating a Machine Learning-based classifier with a previous frequency features extraction using the data obtained from the empirical study. This work is structured as follows: In the next section, a search of previous works related to emotional state classification using ML classifiers is carried out; in the third section, the tools and methodology used in this work (wearable device designing, data collecting protocol, and ML classifier designing) are presented; then, in the fourth section, the results of the process detailed in the previous section are shown, the system developed is compared with previous works, and the results obtained are discussed in detail. Finally, the conclusions obtained from this work are presented. 2. Related works In this section, a search for similar works is performed in order to compare this work at the end of the manuscript. For this purpose, a global search is performed in the most commonly used search engines (IEEExplorer, ScienceDirect, and Google Scholar) using the following search sentence: (‘‘emotional state’’ OR ‘‘affective state’’) AND (‘‘deep learning’’ OR ‘‘machine learning’’) AND ‘‘physiological’’. The resulting set of works is filtered by year, restricting this parameter to those published from 2016 to 2022 (last seven years); and taking into account only those works published in international journals or congresses and only the most-cited works for each year. Preprints or arXiv/bioRxiv works waiting for acceptance are not selected. The results after the search process are filtered by eliminating those that were not focused on a classifier design. The total number of works obtained is 17. The final selected works after the search process are briefly presented and summarized below, but their detailed results are included in the comparison table placed in the results section of this work: •García, Álvarez, and Orozco (2016): in this work, a probabilistic dynamical model is performed on multimodal physiological signals related to affective state to classify between three classes. They use the DEAP dataset (32 participants induced with music videos) with EEG, EMG, EOG and GSR signals. The classifier used is a Supported Vector Machine (SVM). •Liu, Meng, Nandi, and Li (2016): using only the EEG recordings from the same dataset as the previous work (DEAP), the authors use a k-Nearest neighbors and a Random Forest classifiers to distinguish between two classes. •Li et al. (2016): using the DEAP dataset again and only the EEG signals, in this work a 2-class classifier using a combination of Convolutional Neural Network (CNN) and a Recurrent Neural Network (RNN) is used. •Zhang, Chen, Hu, Cao, and Kozma (2016): the DEAP dataset is used again with EEG signals too. Using a Probabilistic Neural Network (PNN), this work classifies between two classes. •Mirmohamadsadeghi, Yazdani, and Vesin (2016): information regarding ECG and breathing patterns obtained from DEAP dataset, this work classifies two different classes using an SVM. •Zheng, Zhu, and Lu (2017): for this work, three different classifiers are analyzed (k-NN, SVM and Logistic Regression) in order to distinguish between three different classes from DEAP dataset •Girardi, Lanubile, and Novielli (2017): with the information given by DEAP dataset, a 2-class classifier based on a VSM is performed using EEG, GSR and EMG signals. •Lee and Yoo (2018): in this case, a custom dataset is recorded using movie clips and bio-sensors (ECG, temperature and GSR). This dataset is used to develop a 2-class classifier using a neural network. •Lee et al. (2019): in this work, authors use a convolutional neural network (CNN) for developing a 2-class classifier using DEAP dataset and the information provided by the photoplethysmograph. •Sonkusare et al. (2019): a custom dataset is collected for this work, developing a CNN classifier for distinguishing two classes using ECG, GSR and temperature sensors. •Lee and Yoo (2020): a classifier based on an RNN is developed for distinguishing between two classes using the information given by ECG, GSR and temperature. The dataset used are DEAP and EMDB. •Domínguez-Jiménez, Campo-Landines, Martínez-Santos, Delahoz, and Contreras-Ortiz (2020): for recognizing between three different emotions (sad, joy and neutral), in this work an SVM classifier is developed using the information given by GRS and photoplethysmograph sensors from DEAP dataset. •Ayata et al. (2020): DEAP dataset is used to train different classifiers based on RF, SVM and Logistic Regression to classify between two classes using the information given by the temperature, the breathing pattern and the photoplethysmograph. •Sepúlveda, Castillo, Palma, and Rodriguez-Fernandez (2021): with the information given by the ECG signal from the AMIGOS dataset, the authors develop an ensemble bagged tree classifier to distinguish between two classes. Expert Systems With Applications 219 (2023) 119577 3 L. Muñoz-Saavedra et al. Fig. 1. Two-dimensional model based on Valence and Arousal. Source: Adaptation from Mehrabian and Russel work. •Tabbaa et al. (2021): In this work, authors develop a 2-class SVM classifier with the information collected in this same work (and shared as VREED dataset). •Hammad and Monkaresi (2022): This author proposes a work where spatial and temporal features are extracted from the signals by a CNN, and later these features are used in a Deep Neural Network (DNN) in order to classify two classes. This work is tested with their own dataset and also with DREAMER dataset. •Jalal and Peer (2022): Finally, in this work the authors propose a framework similar to our work, when they use the Continuous Wavelet Transform to extract information from the signals, and after that they obtained the features using a scalogram processing. The resulting features are used to train a CNN to distinguish between high and low values. They test their method with DEAP dataset. In summary, the vast majority of the works make a classification of two classes (something that this work attempts to improve, increasing it to three classes to facilitate the recognition of emotions). Moreover, despite being a widely used mechanism, there are many papers that use classifiers not based on neural networks. And, finally, it can be observed that there is a little variety of emotion datasets, with DEAP and AMIGOS (by the same authors as DEAP) being the most widely used. The following section will detail the emotional theory, the hardware device and collecting protocol used for this work and, finally, the optimizing process performed to obtain the classifier presented in this work. The comparison with the previous works’ quantitative results is detailed in depth in the final part of the Results section. 3. Materials and methods This section describes the tools used in this work, as well as the methodology used, starting with a quick explanation about the emotional theory. 3.1. Emotional theory Throughout history, different emotions have been identified and different ways of classifying them have been proposed. The classification of emotions is based on a dimensional model of emotions, which allows a classification according to a series of values. These values have changed over the years. But it is finally in 1974, when Mehrabian and Russel simplified the classification of emotions on two axes: Valence and Arousal (Mehrabian Fig. 2. Threshold division according to previous works (Muñoz-Saavedra et al.,2020). & Russell,1974). Previous work has shown that this two-dimensional model of emotions is reliable for classifying emotions (see Fig. 1), and this model is the one used in this work too. The dataset used in this work is labeled using the emotions induced by each case; and the emotions are labeled using three levels for Valence and Arousal (low, middle and high) according to Fig. 1. Additionally, we work with the thresholds used in a previous work (Muñoz-Saavedra et al.,2020) for this division, and include the labeling of the specific emotional states within these ranges according to Fig. 2. In summary, the numerical values labeled in public datasets were divided in that previous work into a range of the lowest 30% to define the ‘‘LOW’’ status, the highest 30% for the ‘‘HIGH’’ status and the middle 40% for the ‘‘MEDIUM’’ status. 3.2. Device and application The hardware device designed for this work is composed of a STMicroelectronics microcontroller and two sensors for capturing physiological signals. The sensors that form it are: •Galvanic Skin Response (GSR) sensor: it measures the electrogalvanic response of the skin, i.e. sweating. In order to measure this response, an electric current must be circulated through the body. This sensor uses two electrodes that are in contact with two fingers. Between these two electrodes there is an integrated circuit that measures the electrical conductivity; and the greater the sweating of the hand, the higher the value obtained. •Photoplethysmograph sensor MAX30100: it consists of two lightemitting diodes, one emitting in the infrared spectrum (950 nm) and the other emitting red light (650 nm), and a photoreceptor. This sensor uses the absorption of blood at red and infrared wavelengths to measure both heart rate and blood oxygen saturation. To measure SPO2it is necessary to know the amount of red light absorbed by the blood, as well as the light absorbed in the infrared spectrum, the ratio between these two values will give us the percentage of oxygen carried by the blood. To measure the heart rate, the small changes that occur when measuring the maximum value of oxygen absorption in the blood will have to be measured, so the SPO2and heart rate values are calculated, and the values given by this module are the amount of light absorbed by the oxygenated hemoglobin (HbO2), associated to the infrared spectrum and the amount of light absorbed by the deoxygenated hemoglobin (Hb), associated to the infrared spectrum. This sensor also includes an infrared thermometer. Expert Systems With Applications 219 (2023) 119577 4 L. Muñoz-Saavedra et al. Fig. 3. Hardware device. So, the physiological signals that are obtained with this device are: •Sweating: obtained directly from the GSR sensor. •Temperature: obtained directly from the MAX30100 sensor. •Heart Rate: obtained indirectly from the HbO2signal of the MAX30100 sensor. •Blood oxygen: obtained indirectly from the relation between Hb and HbO2signals of the MAX30100 sensor. The prototype developed device can be observed in Fig. 3. Regarding the data collecting software, it is integrated with the user application developed for the protocol performed. This application allows the user different tasks: •User ID assignment: needed to distinguish the different participants after the collecting process. •Connection with device: used for selecting the virtual COM port where the device is connected. •Select path to store: selecting the folder where the data collected will be stored. •Recording: there is a bidirectional communication between the user app and the device. The master of this communication is the app, which starts and stops the transmission using specific command. The information recorded is received at 50 hertz. •Videoclip visualization: when the system starts collecting, due to the protocol (described next), the app stars showing some movie clips. The main frame of the developed software is shown in Fig. 4. After presenting the device and the user application developed for this work, the collection protocol followed and the resulting dataset will be detailed next. 3.3. Dataset For the collection of the dataset used in this work, we have considered a population between 18 and 65 years of age, with basic handling of a digital device, who do not have vision difficulties and who do not suffer from any medical disorder that affects the recording of physiological samples (such as heart problems, lung problems, thyroid problems, nervous system disorders, etc.). Following a protocol approved by the university’s ethics committee, the device detailed above is used to collect physiological activity samples while inducing emotional states in the participants through a battery of videos (Megías, Mateos, Ribaudi, & Fernández-Abascal, 2011). The videos used in this process are the ones described in the previous work. Table 1 Dataset samples collected for each class of Arousal and Valence. Temporal window (s) Class Subset 2 3 4 5 LOW Train 806 531 398 317 Test 202 133 100 79 Total 1008 664 498 396 MID Train 299 187 147 114 Test 75 49 37 28 Total 374 246 184 142 HIGH Train 605 403 299 235 Test 151 101 75 59 Total 756 504 374 294 GLOBAL Train 1710 1131 845 666 Test 428 283 211 166 Total 2138 1414 1056 832 In addition, after each viewing, the user fills in the Discrete Emotions Questionnaire (DEQ), where he/she will determine what he/she feels after watching the video and what emotional state it has evoked in him/her. The whole process lasts between 45 and 60 minutes per participant. The collection process is detailed in Fig. 5. In this figure it can be seen how, after viewing each video clip, the participant has an interview with an expert psychologist in which he/she is asked about the emotion evoked by the video he/she has watched, by filling in the DEQ. The result of this questionnaire is used as a label for the physiological signals collected during the video clip, taking into account that only those sections in which the corresponding event occurs in the video are labeled. So, the physiological signals captured by the wearable device are subsequently tagged to an affective state (duple Arousal and Valence), taking into account the time stamps of the events in the videos. Finally, after more than one month of collection, we managed to record information from 22 participants, 14 of whom were men and 8 women, with an average age of 31.67 years. Although the collected dataset does not contain numerous participants, it is large enough to be able to test the theory. It is also important to note that the dataset continues to expand week by week. Since the duration of the videos varies from less than a minute to several minutes, numerous samples are obtained with the 22 participants since, as previously mentioned, the time windows to be analyzed vary between 2 and 5 seconds. The number of samples contained is the same for Arousal and Valence, and it is shown in Table 1. It is important to note that the samples presented in Table 1 only include the number of temporal windows labeled for all the recordings (only a few seconds for each video). With the total amount of videos shown to each participant, the recording time collected for this test was more than 12 hours (and it was necessary more than 50 hours for this collection spread over six weeks, due to the pauses included between the videos and the notations and surveys performed for each participant). 3.4. Classifier The classifier used for this work consists of a classical neural network (MLP, or multilayer perceptron) with an input layer, an output layer and two hidden layers. The inputs to the classifier are the features extracted from the physiological signals of the participants, using a specific window width. Due to the nature of the sensors, these features may vary: specifically, the body temperature sensor provides an absolute value and, therefore, it is not useful to extract frequency features, but statistical variables; on the other hand, the sweating sensor and the photoplethysmograph (from which the oxygenated and deoxygenated hemoglobin signals Expert Systems With Applications 219 (2023) 119577 5 L. Muñoz-Saavedra et al. Fig. 4. User application. Fig. 5. Collection process. are extracted), both provide oscillating and repetitive signals whose frequency information is of special interest. In the case of this work, 5 temporal characteristics are extracted from the temperature sensor (arithmetic mean, quadratic mean, standard deviation, maximum and minimum), and 8 frequency characteristics from both the sweating signal and the oxygenated and deoxygenated hemoglobin signals (mean, deviation, amplitude and zero crossing of both the tonic and phasic signals). These features are summarized in Table 2. Networks with different number of neurons and different values of hyperparameters (to be described later) are evaluated. In the same way, independent systems are trained for each sensor in order to, later on, realize combinations of sensors. This process can be summarized in Fig. 6. The optimization process followed in this work to obtain the best classifier is divided into four phases that will be described below: •Phase 1 — Hyperparameters adjustment: multiple trainings for each individual sensor are performed by varying the batch size and the time window values, as well as various alternatives of the architecture based on the number of layers and the number of neurons. In more detail, batch size is the parameter that indicates the number of samples used in each iteration of the training process before updating any parameter. As more samples are used in each iteration, the parameters will suffer less updates. However, very low samples used can lead to overfitting the model. Another parameter adjusted is the time window, which indicates the width (in seconds) of the window used to extract the frequency features. Other hyperparameters, like learning rate Expert Systems With Applications 219 (2023) 119577 6 L. Muñoz-Saavedra et al. Table 2 Features summary for each signal. Signal # Features Temperature 5 Min, Max, Arithmetic mean, Geometric mean, Standard deviation HbO28 Tonic: Zero crossings, Arithmetic mean, Standard deviation, Amplitude Phasic: Zero crossings, Arithmetic mean, Standard deviation, Amplitude Hb 8 Tonic: Zero crossings, Arithmetic mean, Standard deviation, Amplitude Phasic: Zero crossings, Arithmetic mean, Standard deviation, Amplitude GSR 8 Tonic: Zero crossings, Arithmetic mean, Standard deviation, Amplitude Phasic: Zero crossings, Arithmetic mean, Standard deviation, Amplitude Fig. 6. Graphical abstract. or dropout, are set following the results obtained in the previous work (Muñoz-Saavedra et al.,2020). Table 3 shows the summary of the hyperparameter values used in this grid search process. 36 combinations will be evaluated to obtain an optimal hyperparameter adjustment. •Phase 2 — Best candidates selection: the previously obtained results are discussed and the best cases are selected, which will be used in the following phases. •Phase 3 — Ensembles: the sensors that include the best candidates are joint forming an ensemble classifier with the information obtained from those sensors. Results are shown. •Phase 4 — Exhaustive candidate assessment: more exhaustive tests are performed over the previously ensemble using different techniques to assess the robustness by using cross-validation, and the final results are detailed and discussed using different evaluation metrics. 3.5. Evaluation metrics To evaluate the effectiveness in the classification results of a classifier, the most common metrics are used: accuracy (most-used metric), sensitivity (known as recall in other works), specificity, precision, and F1𝑠𝑐𝑜𝑟𝑒 (Sokolova et al.,2009). To this end, the classification results Table 3 Hyperparameter’s values. Hyperparameter Values Learning rate 1e−4 Temporal window (s) 2, 3, 4, 5 Batch size 8, 16, 32 Hidden-layers size 32:16, 64:32, 128:64 obtained for each class are tagged as ‘‘True Positive’’ (TP), ‘‘True Negative’’ (TN), ‘‘False Positive’’ (FP) or ‘‘False Negative’’ (FN). According to them, the high-level metrics are presented in the next equations: Accuracy = ∑ 𝑐 TP𝑐+ TN𝑐 TP𝑐+ FP𝑐+ TN𝑐+ FN𝑐 , 𝑐 ∈𝑐𝑙𝑎𝑠𝑠𝑒𝑠 (1) Sensitivity = ∑ 𝑐 TP𝑐 TP𝑐+ FN𝑐 , 𝑐 ∈𝑐𝑙𝑎𝑠𝑠𝑒𝑠 (2) Specificity = ∑ 𝑐 TN𝑐 TN𝑐+ FP𝑐 , 𝑐 ∈𝑐𝑙𝑎𝑠𝑠𝑒𝑠 (3) Precision = ∑ 𝑐 TP𝑐 TP𝑐+ FP𝑐 , 𝑐 ∈𝑐𝑙𝑎𝑠𝑠𝑒𝑠 (4) F1𝑠𝑐𝑜𝑟𝑒 =2∗ precision ∗ sensitivity precision + sensitivity .(5) Expert Systems With Applications 219 (2023) 119577 7 L. Muñoz-Saavedra et al. Table 4 Results obtained for HbO2signal for the three architectures when classifying Arousal. Architecture Window (s) Batch size 8 16 32 Train Test Train Test Train Test Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss 128:64 296.82 0.0964 99.66 0.0609 96.76 0.0899 93.42 0.7574 94.63 0.1355 95.01 0.2113 398.38 0.0524 100.00 0.0150 98.45 0.0433 65.10 94.3020 42.73 1.0775 62.23 0.9836 499.42 0.0174 100.00 0.0089 98.18 0.0569 100.00 0.0377 98.56 0.0564 100.00 0.0335 599.20 0.0368 75.44 4.1654 97.87 0.0634 100.00 0.0496 99.02 0.0393 91.30 3.0769 64:32 286.06 0.3660 83.77 0.4447 85.37 0.3532 77.23 0.7721 87.74 0.3270 70.31 1.1107 392.52 0.2106 97.93 0.1256 90.83 0.2544 93.75 0.2224 89.66 0.2773 87.32 0.3727 493.82 0.1615 98.00 0.0780 91.67 0.2276 89.38 0.3155 93.05 0.1894 93.20 0.3107 591.67 0.2533 92.22 0.3457 92.24 0.2187 97.75 0.1034 90.87 0.2394 78.23 1.1948 32:16 2 40.02 1.3512 80.66 0.7006 75.16 0.5479 57.12 1.1362 41.00 1.1200 57.19 1.0101 3 77.61 0.5854 74.31 0.8201 23.78 1.6896 51.97 1.0819 74.45 0.5789 69.61 0.7072 485.22 0.4142 65.00 1.5811 80.67 0.4484 72.43 0.9505 73.93 0.5892 74.11 0.7346 586.37 0.3616 77.02 0.7553 83.58 0.4027 58.85 52.6437 80.74 0.4558 79.82 0.4815 Table 5 Results obtained for HbO2signal for the three architectures when classifying Valence. Architecture Window (s) Batch size 8 16 32 Train Test Train Test Train Test Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss 128:64 297.76 0.0669 76.89 3.1621 96.64 0.1056 99.54 0.0603 94.85 0.1435 95.76 0.1545 399.50 0.0263 93.20 0.7699 97.42 0.0923 98.68 0.0714 98.15 0.0536 95.20 0.5982 4 64.16 0.7936 77.97 0.9352 99.23 0.0243 97.30 0.4014 96.55 0.1161 99.68 0.0659 599.27 0.0343 97.48 0.1278 98.87 0.0341 88.71 2.1190 98.04 0.0799 54.72 5.4271 64:32 288.09 0.3178 75.85 0.8349 88.88 0.2874 65.03 2.9453 85.31 0.3849 81.16 0.4762 391.74 0.2296 89.96 0.7649 88.80 0.2921 89.56 0.4209 87.26 0.3445 87.17 0.3021 495.54 0.1333 100.00 0.0459 94.00 0.1857 95.37 0.2365 92.48 0.1903 89.78 0.5080 595.05 0.1467 98.47 0.1198 95.76 0.1419 94.95 0.2163 88.08 0.2962 98.39 0.1497 32:16 2 70.95 0.6808 73.08 0.6246 74.35 0.5782 46.32 1.1140 76.67 0.5274 72.30 0.6236 382.09 0.4363 74.31 0.6553 75.28 0.5367 77.60 0.5379 75.89 0.5597 68.20 0.6840 482.22 0.4517 79.64 0.4986 81.84 0.4340 73.52 0.9603 74.83 0.6006 70.86 0.7179 587.94 0.3089 66.53 1.4393 83.17 0.4508 73.09 0.6896 78.68 0.4862 84.00 0.4635 About those metrics: •Accuracy: all samples classified correctly compared to all samples (see Eq. (1)). •Sensitivity (or recall): proportion of values classified as ‘‘true positive’’ that are correctly classified (see Eq. (2)). •Specificity: proportion of values classified as ‘‘true negative’’ that are correctly classified (see Eq. (3)). •Precision: proportion of values classified as ‘‘true positive’’ in all cases that have been classified as it (see Eq. (4)). •F1𝑠𝑐𝑜𝑟𝑒: It considers two of the main metrics (precision and sensitivity), calculating the harmonic mean of both parameters (see Eq. (5)). The above metrics are common to all ML systems; but there are other commonly used metrics in healthcare systems; this is the case of the ROC curve (Receiver Operating Characteristic) (Hoo, Candlish, & Teare,2017), because it is the visual representation of the True Positives Rate (TPR) versus the False Positives Rate (FPR) as the discrimination threshold is varied. Usually, when using the ROC curve, the area under the curve (AUC) is used as a value of the system’s goodness- of-fit. Therefore, the classifier system developed in this work will be evaluated according to all the metrics detailed in this subsection. 4. Results and discussions The results obtained in the four phases used to optimize the classifier will be presented in order. Similarly, as results are presented, the candidates chosen in each phase will be determined according to the evaluation metrics obtained. Once the best classifier is obtained, a thorough comparison will be made with the works detailed in Section 2. 4.1. Classifier implementation and evaluation Starting with the design and evaluation of the classifier, independent classifiers will be trained for each sensor, the best candidates will be extracted and, based on them, combinations will be made to obtain the final results. 4.1.1. Phase 1: Grid search The results in this section will be presented as follows: for each signal, two tables will be shown: one for Arousal and the other for Valence. Each of these tables will contain the classification results (accuracy and loss) for the training and testing subsets for each combination of hyperparameter (batch size: 8, 16 and 32; and temporal window: 2, 3, 4 and 5) and for each network architecture (128:64, 64:32 and 32:16). First, results for HbO2signal are shown in Table 4 for Arousal, and in Table 5 for Valence. As can be observed in Table 4, the best results seem to be located in the temporal width of four seconds for the most complex architecture (128:64). Acceptable results are colored in yellow, good results in green and bad results in red. Even so, it can be seen how this signal with this architecture achieves good classification results. Moreover, as presented in Table 5, there are some good results with particular parameters, but it seems that this signal has more difficulty to classify Valence. Expert Systems With Applications 219 (2023) 119577 8 L. Muñoz-Saavedra et al. Table 6 Results obtained for temperature signal for the three architectures when classifying Arousal. Architecture Window (s) Batch size 8 16 32 Train Test Train Test Train Test Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss 128:64 2 76.95 0.5172 67.97 0.6919 77.30 0.5124 66.49 0.7339 73.45 0.5998 84.55 0.4458 3 78.72 0.4849 74.28 0.6006 74.71 0.5726 79.69 0.6837 77.35 0.5291 69.01 0.7845 4 72.80 0.6069 87.76 0.4371 75.11 0.5356 81.95 0.8057 79.13 0.4963 76.43 0.6124 5 76.41 0.5247 74.17 0.8297 80.18 0.4552 62.30 0.8469 78.00 0.4943 89.09 0.4082 64:32 2 67.92 0.7016 70.52 0.7744 74.17 0.5891 57.00 3.1390 69.82 0.6394 84.95 0.4721 3 60.87 0.8337 69.29 0.8742 75.36 0.5977 60.41 0.8467 73.28 0.5812 67.42 7.1094 4 75.64 0.5494 68.77 0.8640 74.05 0.5907 80.14 0.5523 74.16 0.5965 80.33 0.5245 5 48.56 1.0043 67.41 0.9441 70.73 0.6474 59.89 1.1397 73.52 0.6286 72.16 0.7214 32:16 2 59.72 0.8848 49.36 1.0804 54.92 0.9303 52.09 1.1098 68.22 0.6724 72.37 0.7119 3 62.80 0.8037 53.72 1.0854 67.18 0.7144 84.55 0.4601 61.26 0.8315 65.17 0.8217 4 72.90 0.6409 61.54 0.8814 68.73 0.7108 69.43 1.1181 35.55 3.4068 72.79 0.8866 5 66.86 0.7537 74.19 0.7535 73.58 0.6144 75.60 0.6375 67.63 0.7383 68.90 0.8337 Table 7 Results obtained for temperature signal for the three architectures when classifying Valence. Architecture Window (s) Batch size 8 16 32 Train Test Train Test Train Test Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss 128:64 2 73.59 0.5765 59.95 0.9190 70.31 0.6622 62.74 0.9986 72.18 0.6165 87.28 0.3796 3 71.53 0.6191 81.01 0.5996 74.69 0.5670 74.79 0.6597 74.40 0.6111 72.88 0.6619 4 76.59 0.5474 77.70 0.5398 72.88 0.6434 53.81 2.9568 73.33 0.6337 70.51 0.7008 5 78.81 0.4882 72.13 0.8003 78.76 0.4555 77.10 0.5534 79.45 0.4718 82.01 0.5040 64:32 2 71.77 0.6190 60.99 0.9361 69.99 0.7037 56.11 0.9875 74.14 0.5815 70.92 0.6701 3 72.53 0.6455 72.92 0.6522 71.58 0.6407 55.84 1.0169 75.24 0.5731 69.48 0.8485 4 76.94 0.5242 64.57 0.9307 71.11 0.6475 70.28 0.8665 65.66 0.7527 68.34 0.8473 5 69.73 0.6372 82.69 0.5349 67.70 0.7176 67.29 0.7782 74.75 0.5728 56.30 1.3354 32:16 2 43.80 1.0522 67.24 1.0676 70.13 0.6706 71.65 0.7320 65.17 0.7606 66.01 0.8367 3 71.46 0.6284 70.37 0.7747 67.77 0.7357 59.72 1.0666 67.16 0.6960 61.95 0.9288 4 63.07 0.8316 71.57 0.7452 71.34 0.6408 73.73 0.8750 64.45 0.7808 74.57 0.7612 5 59.34 0.8587 64.95 0.8245 72.87 0.6514 62.03 1.0203 61.74 0.8240 52.75 1.1462 For the 64:32 architecture, classifiers’ accuracy decreased due to the architecture complexity reduction, however some cases obtain acceptable results (over 90%). Finally, as expected, results are clearly worse with the 32:16 architecture than the ones obtained in the previous ones. However, accuracy stands around 85% in some cases for Arousal and Valence. Secondly, results for temperature signal are shown in Table 6 for Arousal, and in Table 7 for Valence. As can be observed in Table 6, the temperature sensor rating results for Arousal are mostly poor for the most complex architecture. Therefore, it is clear that this sensor would not be suitable in this case. Moreover, the temperature sensor does not perform well when classifying Valence. The best cases obtain around 80%–89% accuracy for Arousal and even less for Valence. For the 64:32 architecture, the results are even worse: The best cases obtain around 80%–84% accuracy. And, finally, for the lighter architecture, accuracy results obtained are around 60%–70%. In third place, results for GSR signal are shown in Table 8 for Arousal, and in Table 9 for Valence. As can be observed in Table 8, the classification results for the GSR signal with Arousal are not very good. There are cases where acceptable results are obtained with the 128:64 architecture, but the vast majority are low results. For Valence, the GSR signal seems to obtain acceptable classification results with the heavier architecture, exceeding 94% in most cases. Summarizing, GSR sensor may be used for Valence classification, but next results will show if there is no other sensor that obtains better results. After some promising results with the 128:64 architecture, the middle architecture’s results continues the same tendency by obtaining very good results (over 90% in most cases). And, finally, for the lighter architecture, although some results are not acceptable, in the most cases results over 85% are obtained. These results give this sensor the first position in terms of accuracy so far. The fourth signal evaluated if the deoxygenated hemoglobin (Hb). Its results for Hb signal are shown in Table 10 for Arousal, and in Table 11 for Valence. Results in Table 10 shown that there are acceptable results for classifying Arousal with Hb signal using the heavier architecture, although Loss values are too high. Results for Valence show that acceptable results are obtained for Hb signal, but there are several values with high Loss values. Although, with the 128:64 architecture, results were very promising, with the 64:32 architecture the accuracy plummet this time. There are some cases where accuracy surrounds 90%, but most of them are around 80%–85%, and worse results are obtained for Arousal. Finally, for the lighter architecture, as happened before, results obtained are lower. In comparison with the other signals, it obtains worse results than HbO2and GSR sensors, but not as low as temperature sensor. The results presented are summarized as follows: •Regarding the results obtained exclusively for the 128:64 architecture, two signals stand out: HbO2and sweating (GSR sensor). Temperature sensor is the one with the worst results, and Hb signal presents too high Loss values. •Regarding the results with the other architectures, some conclusions could be made: temperature sensor is not suitable to be used, and Hb signal experiments a high decreasing from the first architecture to this one. So, HbO2and GSR seems to be the signals that provide the most information. Expert Systems With Applications 219 (2023) 119577 9 L. Muñoz-Saavedra et al. Table 8 Results obtained for GSR signal for the three architectures when classifying Arousal. Architecture Window (s) Batch size 8 16 32 Train Test Train Test Train Test Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss 128:64 298.90 0.0368 80.58 4.2113 97.53 0.0711 74.23 4.6345 96.97 0.0795 72.62 11.3095 397.11 0.0787 99.33 0.0538 94.62 0.1527 65.98 6.7071 96.45 0.1113 99.02 0.0912 497.75 0.0706 100.00 0.0401 95.98 0.1020 100.00 0.0347 92.07 0.2168 90.91 0.3499 596.20 0.0779 99.12 0.0556 97.45 0.0721 81.61 3.0394 93.84 0.1424 92.80 0.4396 64:32 293.29 0.1840 94.86 0.1909 91.37 0.2325 89.35 0.3223 93.76 0.1744 70.72 1.9500 389.39 0.2680 92.05 0.2439 90.49 0.2840 92.37 0.5006 84.16 0.3977 90.71 0.2729 492.27 0.1972 78.76 0.7776 90.66 0.2498 92.22 0.4018 87.44 0.3114 92.69 0.3024 592.82 0.2053 96.05 0.1896 91.04 0.2189 89.15 0.4125 85.42 0.3828 88.56 0.3544 32:16 284.02 0.4255 87.33 0.3317 83.39 0.4428 82.56 0.4626 76.54 0.6018 69.82 0.8183 387.14 0.3266 86.85 0.3478 82.29 0.4534 67.28 1.3948 82.56 0.4612 65.79 0.7522 485.35 0.3774 79.55 0.5427 83.31 0.4070 80.31 0.5278 79.33 0.5642 62.15 1.0934 584.72 0.4255 82.07 0.5128 75.24 0.6139 75.69 0.6652 77.06 0.5643 75.76 0.6351 Table 9 Results obtained for GSR signal for the three architectures when classifying Valence. Architecture Window (s) Batch size 8 16 32 Train Test Train Test Train Test Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss 128:64 296.66 0.1079 100.00 0.0228 97.75 0.0641 100.00 0.0298 98.12 0.0539 100.00 0.0076 396.11 0.1018 100.00 0.0404 97.32 0.0773 100.00 0.0391 95.32 0.1373 100.00 0.0489 494.31 0.1522 100.00 0.0454 96.73 0.0858 95.96 2.3339 94.27 0.1246 100.00 0.0495 596.48 0.0932 75.00 7.4356 94.60 0.1398 68.71 10.5939 95.56 0.1158 89.17 0.8851 64:32 294.22 0.1612 97.78 0.0715 91.47 0.2465 94.42 0.2036 91.00 0.2455 87.06 0.4023 393.05 0.1812 97.47 0.1212 90.94 0.2261 75.94 6.6802 85.92 0.3749 86.83 0.3579 493.42 0.2030 94.74 0.1974 89.71 0.2897 75.00 2.2000 88.55 0.3019 91.39 0.3123 591.58 0.2197 93.89 0.1981 86.35 0.3734 85.09 1.2349 87.35 0.3415 63.81 4.3691 32:16 2 71.63 0.6483 81.98 0.6813 85.15 0.3947 84.80 0.4549 40.60 2.3906 60.47 0.9503 383.89 0.3918 70.50 0.9630 80.41 0.5014 89.77 0.4212 86.33 0.3597 57.45 4.6116 485.51 0.3623 66.18 1.0666 47.10 1.0689 68.75 1.0017 77.52 0.5355 75.54 0.6656 5 48.62 1.1818 73.15 1.0565 81.32 0.4861 63.80 3.1625 79.37 0.5235 80.98 0.5281 Table 10 Results obtained for Hb signal for the three architectures when classifying Arousal. Architecture Window (s) Batch size 8 16 32 Train Test Train Test Train Test Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss Acc (%) Loss 128:64 293.33 0.1752 97.27 0.1558 92.36 0.2106 95.58 0.1473 92.75 0.1938 92.53 0.2251 398.19 0.0511 66.53 4.2423 95.28 0.1421 96.69 0.1441 92.02 0.2109 89.25 0.7027 497.24 0.0733 87.60 6.8105 95.31 0.1245 66.12 6.5035 96.45 0.1089 83.92 1.7006 597.90 0.0730 99.53 0.0606 97.38 0.0617 76.99 3.4677 93.46 0.1698 80.08 1.5687 64:32 2 77.75 0.5148 77.55 0.5431 82.70 0.4061 80.43 0.4695 75.80 0.5554 77.12 0.7400 388.71 0.2999 91.05 0.2867 85.22 0.3742 90.07 0.3927 84.96 0.3967 86.78 0.7335 485.66 0.3368 84.08 0.9400 91.13 0.2647 81.82 0.7712 84.47 0.4056 80.20 0.5402 590.20 0.2706 72.86 2.7277 89.80 0.3212 89.45 0.3221 90.69 0.2457 51.16 5.8066 32:16 2 62.05 0.7986 60.42 0.9100 65.90 0.7420 75.38 0.6226 48.42 1.0092 69.16 0.9327 3 72.54 0.6568 60.96 0.8193 76.11 0.5575 58.85 1.3655 70.59 0.6886 69.58 0.8468 4 77.69 0.5409 58.90 0.8819 67.35 0.7183 72.92 0.7040 73.65 0.6118 47.87 1.1607 5 79.51 0.4971 55.94 1.0931 73.72 0.5942 74.23 0.7133 72.87 0.6297 74.24 0.6313 Therefore, concluding a first reflection on the results obtained individually by each sensor, the temperature sensor would be the first to be discarded, while the Hb sensor would have to be compared more closely with the other two. In the following subsection, the best results obtained by each of these three sensors (definitely discarding the temperature sensor) will be summarized and the best candidates to be used in the combination phase will be discussed. 4.1.2. Phase 2: Best individual candidates The objective of this section is to present, in a more summarized form, the information previously presented. Due to the large amount of information previously shown, it is not easy to simplify it much (so results per sensor and architecture will be presented equally), but the worst sensor (temperature) and the worst results of the remaining ones will be eliminated. In summary, one table per sensor will be presented. Expert Systems With Applications 219 (2023) 119577 16 L. Muñoz-Saavedra et al. by this research group has demonstrated that the computational complexity of an RNN compared to a system with a classical neural network and prior feature extraction is practically 10 times higher when run in an environment without a graphical accelerator (Escobar-Linero, Luna-Perejón, Muñoz-Saavedra, Sevillano, & Domínguez-Morales,2022). Therefore, as this work uses a more complex classifier than a basic RNN, the computational complexity will be more than 10 times that the one needed to run our classifier. •Finally, for the case of Sepúlveda et al. (2021), the results obtained are lower than the best in our work (89.1%–89.3% versus 98.72%–98.63%), although slightly better than those obtained in the mean of the final tests of our work. Even so, the main drawback, apart from only classifying two classes, is that the neural network used for classification is an ensemble of several independent networks, which multiplies the complexity of the system used. Then, if we analyze those works in which three classes are classified, we find Domínguez-Jiménez et al. (2020), García et al. (2016) and Zheng et al. (2017). There is a fourth paper in this case, which is Muñoz-Saavedra et al. (2020), although this paper corresponds to a previous study carried out by the main authors of this paper. In that previous work, the DEAP dataset was also used (like most of the works with which we compare ourselves) with three classes and two sensors, obtaining promising results (90.4% for Valence and 91.7% for Arousal for the best case). If we compare the work presented here with that previous work, we find several significant differences: •The dataset used for this work has been collected by this research group using a device and a protocol developed specifically for the occasion. This is because we wanted to demonstrate that the results obtained with a commercial device (DEAP dataset) were applicable to a customized, low-power device so that, after this work, we could integrate the classifier in the embedded device (this could not be done in the case of the commercial device used in the DEAP dataset). •The development and optimization process of the classifier carried out for this work is much more exhaustive and robust than the one used for the previous work. The use of techniques such as cross-validation and the training of networks combining several sensors are techniques that were not performed in the previous work (in which one sensor was used to classify Arousal and another to classify Valence). •The features extracted in this work, unlike the previous work, are based on a previous study performed over previous work and those who gave the best results in the previous work developed by this group. •The best results obtained in this work improve on those obtained in the previous work (shown in Table 20). It is true that the average results of this work are lower than the best results obtained in previous work; however, the average results of the previous work did not exceed 85%. Finally, comparing ourselves with the works that classify three classes (except for the previous work of this group), we can make the following analysis: •For the case of Domínguez-Jiménez et al. (2020), the classification of this work does not follow the two-dimensional emotional theory of Arousal and Valence, but establishes three clearly differentiated emotions and classifies based on them. If we determine the number of classes of our classifier based on how many different emotions it can distinguish, we can indicate that up to 9 different categories would be classified (3 possible values of Valence ×3 possible values of Arousal). Therefore, although this work has been indicated as a 3-class classifier, the information it provides is inferior even to a 2-class classifier using two-dimensional emotional theory (since, in that case, up to 4 emotional classifications could be distinguished). •For the case of Zheng et al. (2017), three different classifiers are used, and none of them is a neural network. Moreover, the results obtained in this work are much lower that the ones obtained in our work (79.3% versus 98.63%–98.72% for the best case). •And, finally, for the case of García et al. (2016), this is the work with the most similarities with our work. In this work, three classes are used (same as our classifier) and the results obtained are very similar to those obtained in our work in average (although the best case of our work surpasses it a 9%). In this case, the sensors used are not similar to ours: while we use the GSR and PPG signal, this work uses EEG (discarded by us in the previous work due to poor results), EMG and EOG. It is interesting to note that, using a classifier based on SVM, the results are quite good. Therefore, even if our work obtains better results, we will analyze the sensors used in this work for future developments to see if improvements in the classifier are achieved. Finally, it should be noted that the purpose of our work is to integrate the classifier in a non-invasive wearable system; but, in the case of this work, the device should be placed on the head to capture oculography information, facial muscle activity and electrical activity of the cerebral cortex. Therefore, our system is much less invasive than the one indicated in this work. In summary, an analysis of the most important studies of recent years shows that very few studies actually distinguish between the three classes and, among those that do, the results obtained are inferior to those obtained in our study. Even so, for future work we will carry out more exhaustive comparisons with different types of classifiers and sensors according to what has been observed in previous works. 5. Conclusions The affective or emotional state of a person can be measured by variations of physiological signals and is related to the two-dimensional emotional theory theorized by Mehrabian and Russell (1974). In this work, a non-invasive wearable device is developed, composed of several physiological sensors, which is capable of capturing such information in real time and storing it in a computer. With this, a protocol is designed, endorsed by an ethical committee, in which emotions are induced in a group of participants using audiovisual information while the physiological data information registered in real time by the wearable device is recorded. This collected dataset is labeled based on Arousal and Valence values according to the two-dimensional emotional theory, and an automatic classifier is designed based on neural networks with prior extraction of frequency characteristics of the physiological signals. For the design of this classifier, a meticulous process consisting of four phases is followed: first, all the sensors are evaluated; second, the most suitable sensors are determined; third, combinations of different sensors are performed; and, finally, the robustness of the final classifier is evaluated by applying cross-validation techniques on the developed neural network. The test subset classification results of the designed neural network exceed, for the best case, 98% for both Arousal and Valence. If we compare the results obtained with previous works, improvements are observed in the number of classes used by the classifier, its accuracy, system architecture complexity, and the non-invasive wearable. These results demonstrate the feasibility of using a wearable system for the classification of the user’s emotional state. Furthermore, the results obtained, the network simplicity, and the non-invasive wearable allow our system to be analyzed in order to integrate it into the embedded system in future work. Expert Systems With Applications 219 (2023) 119577 17 L. Muñoz-Saavedra et al. CRediT authorship contribution statement Luis Muñoz-Saavedra: Software tests, Writing. Elena Escobar- Linero: Tests, Writing. Lourdes Miró-Amarante: Conceptualization, Methodology, Writing. M. Rocío Bohórquez: Protocol, Data collection, Interviews. Manuel Domínguez-Morales: Conceptualization, Methodology, Writing, Coordination, Supervision. Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. Data availability Data will be made available on request. Acknowledgments This work was supported by the Spanish AEI project MINDROB, Spain (PID2019-105556GB-C33), and by the Andalusian Regional I+D+i FEDER, Spain Projects DAFNE US-1381619 and MSF-PHIA, Spain US- 1263715. References Ardern, C. L., Kvist, J., & Webster, K. E. (2016). Psychological aspects of anterior cruciate ligament injuries. Operative Techniques in Sports Medicine,24, 77–83. Ayata, D., Yaslan, Y., & Kamasak, M. E. (2020). Emotion recognition from multimodal physiological signals for emotion aware healthcare systems. Journal of Medical and Biological Engineering,40, 149–157. Biagetti, G., Crippa, P., Falaschetti, L., Tanoni, G., & Turchetti, C. (2018). A comparative study of machine learning algorithms for physiological signal classification. Procedia Computer Science,126, 1977–1984. Civit-Masot, J., Domínguez-Morales, M. J., Vicente-Díaz, S., & Civit, A. (2020). Dual machine-learning system to aid glaucoma diagnosis using disc and cup feature extraction. IEEE Access,8, 127519–127529. Civit-Masot, J., Luna-Perejón, F., Corral, J. M. R., Domínguez-Morales, M., Morgado- Estevez, A., & Civit, A. (2021). A study on the use of edge TPUs for eye fundus image segmentation. Engineering Applications of Artificial Intelligence,104, Article 104384. Civit-Masot, J., Luna-Perejón, F., Domínguez Morales, M., & Civit, A. (2020). Deep learning system for COVID-19 diagnosis aid using X-ray pulmonary images. Applied Sciences,10, 4640. Diener, E., & Chan, M. Y. (2011). Happy people live longer: Subjective well-being contributes to health and longevity. Applied Psychology: Health and Well-Being,3, 1–43. DiMaria, C. H., Peroni, C., & Sarracino, F. (2020). Happiness matters: Productivity gains from subjective well-being. Journal of Happiness Studies,21, 139–160. Domínguez-Jiménez, J. A., Campo-Landines, K. C., Martínez-Santos, J. C., Delahoz, E. J., & Contreras-Ortiz, S. H. (2020). A machine learning model for emotion recognition from physiological signals. Biomedical Signal Processing and Control,55, Article 101646. Domínguez-Morales, M. J., Luna-Perejón, F., Miró-Amarante, L., Hernández- Velázquez, M., & Sevillano-Ramos, J. L. (2019). Smart footwear insole for recognition of foot pronation and supination using neural networks. Applied Sciences,9, 3970. Escobar-Linero, E., Domínguez-Morales, M., & Sevillano, J. L. (2022). Worker’s physical fatigue classification using neural networks. Expert Systems with Applications,198, Article 116784. Escobar-Linero, E., Luna-Perejón, F., Muñoz-Saavedra, L., Sevillano, J. L., & Domínguez- Morales, M. (2022). On the feature extraction process in machine learning. An experimental study about guided versus non-guided process in falling detection systems. Engineering Applications of Artificial Intelligence,114, Article 105170. Frey, B. S., & Stutzer, A. (2016). Policy consequences of happiness research. In Policies for Happiness (pp. 21–35). Oxford: Oxford University Press. García, H. F., Álvarez, M. A., & Orozco, Á. A. (2016). Gaussian process dynamical models for multimodal affect recognition. In 2016 38th A nnual international conference of the ieee engineering in medicine and biology society (pp. 850–853). IEEE. Girardi, D., Lanubile, F., & Novielli, N. (2017). Emotion detection using noninvasive low cost sensors. In 2017 seventh international conference on affective computing and intelligent interaction (pp. 125–130). IEEE. Hammad, D. S., & Monkaresi, H. (2022). ECG-based emotion detection via parallelextraction of temporal and spatial features using convolutional neural network. Traitement du Signal,39. Harmon-Jones, C., Bastian, B., & Harmon-Jones, E. (2016). The discrete emotions questionnaire: A new tool for measuring state self-reported emotions. PLoS One, 11, Article e0159915. Hoo, Z. H., Candlish, J., & Teare, D. (2017). What is an ROC curve? Emergency Medicine Journal,34, 357–359. Howell, R. T., Kern, M. L., & Lyubomirsky, S. (2007). Health benefits: Metaanalytically determining the impact of well-being on objective health outcomes. Health Psychology Review,1, 83–136. Hu, T. -Y., Xie, X., & Li, J. (2013). Negative or positive? The effect of emotion and mood on risky driving. Transportation Research Part F: Traffic Psychology and Behaviour, 16, 29–40. Jalal, L., & Peer, A. (2022). Emotion recognition from physiological signals using continuous wavelet transform and deep learning. In International conference on human-computer interaction (pp. 88–99). Springer. Kwon, Y. -H., Shin, S. -B., & Kim, S. -D. (2018). Electroencephalography based fusion two-dimensional (2D)-convolution neural networks (CNN) model for emotion recognition system. Sensors,18, 1383. Lee, M. S., Lee, Y. K., Pae, D. S., Lim, M. T., Kim, D. W., & Kang, T. K. (2019). Fast emotion recognition based on single pulse PPG signal with convolutional neural network. Applied Sciences,9, 3355. Lee, J., & Yoo, S. K. (2018). Design of user-customized negative emotion classifier based on feature selection using physiological signal sensors. Sensors,18, 4253. Lee, J., & Yoo, S. K. (2020). Recognition of negative emotion using long short-term memory with bio-signal feature compression. Sensors,20, 573. Li, X., Song, D., Zhang, P., Yu, G., Hou, Y., & Hu, B. (2016). Emotion recognition from multi-channel EEG data through convolutional recurrent neural network. In 2016 IEEE international conference on bioinformatics and biomedicine (pp. 352–359). IEEE. Liu, J., Meng, H., Nandi, A., & Li, M. (2016). Emotion detection from EEG recordings. In 2016 12th international conference on natural computation, fuzzy systems and knowledge discovery (pp. 1722–1727). IEEE. Luna-Perejón, F., Domínguez-Morales, M. J., & Civit-Balcells, A. (2019). Wearable fall detector using recurrent neural networks. Sensors,19, 4885. Luna-Perejón, F., Domínguez-Morales, M., Gutiérrez-Galán, D., & Civit-Balcells, A. (2020). Low-power embedded system for gait classification using neural networks. Journal of Low Power Electronics and Applications,10, 14. Luna-Perejón, F., Muñoz-Saavedra, L., Civit-Masot, J., Civit, A., & Domínguez- Morales, M. (2021). AnkFall—Falls, falling risks and daily-life activities dataset with an ankle-placed accelerometer and training using recurrent neural networks. Sensors,21, 1889. Megías, C. F., Mateos, J. C. P., Ribaudi, J. S., & Fernández-Abascal, E. G. (2011). Validación española de una batería de películas para inducir emociones. Psicothema, 778–785. Mehrabian, A., & Russell, J. A. (1974). An approach to environmental psychology. The MIT Press. Mirmohamadsadeghi, L., Yazdani, A., & Vesin, J. -M. (2016). Using cardio-respiratory signals to recognize emotions elicited by watching music video clips. In 2016 IEEE 18th international workshop on multimedia signal processing (pp. 1–5). IEEE. Muñoz-Saavedra, L., Luna-Perejón, F., Civit-Masot, J., Miró-Amarante, L., Civit, A., & Domínguez-Morales, M. (2020). Affective state assistant for helping users with cognition disabilities using neural networks. Electronics,9, 1843. Neumann, W. P., & Dul, J. (2010). Human factors: Spanning the gap between OM and HRM. International Journal of Operations & Production Management. Ødegaard, F., & Roos, P. (2014). Measuring the contribution of workers’ health and psychosocial work-environment on production efficiency. Production and Operations Management,23, 2191–2208. Santamaria-Granados, L., Munoz-Organero, M., Ramirez-Gonzalez, G., Abdulhay, E., & Arunkumar, N. (2018). Using deep convolutional neural network for emotion detection on a physiological signals dataset (AMIGOS). IEEE Access,7, 57–67. Sepúlveda, A., Castillo, F., Palma, C., & Rodriguez-Fernandez, M. (2021). Emotion recognition from ECG signals using wavelet scattering and machine learning. Applied Sciences,11. Sokolova, M., et al. (2009). A systematic analysis of performance measures for classification tasks. Information Processing & Management,45, 427–437. Sonkusare, S., Ahmedt-Aristizabal, D., Aburn, M. J., Nguyen, V. T., Pang, T., Frydman, S., et al. (2019). Detecting changes in facial temperature induced by a sudden auditory stimulus based on deep learning-assisted face tracking. Scientific Reports, 9, 1–11. Tabbaa, L., Searle, R., Bafti, S. M., Hossain, M. M., Intarasisrisawat, J., Glancy, M., et al. (2021). VREED: Virtual reality emotion recognition dataset using eye tracking & physiological measures. In Proceedings of the ACM on interactive, mobile, wearable and ubiquitous technologies:vol. 5, (pp. 1–20). NY, USA: ACM New York. Te Wierike, S., van der Sluis, v. d. A., van den Akker-Scheek, I., Elferink-Gemser, M., & Visscher, C. (2013). Psychosocial factors influencing the recovery of athletes with anterior cruciate ligament injury: A systematic review. Scandinavian Journal of Medicine & Science in Sports,23, 527–540. Tenney, E. R., Poole, J. M., & Diener, E. (2016). Does positivity enhance work performance?: Why, when, and what we don’t know. Research in Organizational Behavior,36, 27–46. Expert Systems With Applications 219 (2023) 119577 18 L. Muñoz-Saavedra et al. Ton, Z. (2014). The good jobs strategy: How the smartest companies invest in employees to lower costs and boost profits. Houghton Mifflin Harcourt. Wiese-Bjornstal, D. M., Smith, A. M., Shaffer, S. M., & Morrey, M. A. (1998). An integrated model of response to sport injury: Psychological and sociological dynamics. Journal of Applied Sport Psychology,10, 46–69. Zhang, J., Chen, M., Hu, S., Cao, Y., & Kozma, R. (2016). PNN for EEG-based emotion recognition. In 2016 IEEE international conference on systems, man, and cybernetics (pp. 002319–002323). IEEE. Zheng, W. -L., Zhu, J. -Y., & Lu, B. -L. (2017). Identifying stable patterns over time for emotion recognition from EEG. IEEE Transactions on Affective Computing.