Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 352 Potential of ORC Systems to Retrofit CHP Plants in Wastewater Treatment Stations Ricardo Chacartegui * , Jose Muñoz de Escalona, Jose A. Becerra, Alonso Fernández, David Sánchez Department of Energy Engineering University of Seville, Seville, Spain email:
[email protected] Cite as: Chacartegui, R., Muñoz de Escalona, J., Becerra, J.A., Fernández, A., Sánchez, D., Potential of ORC Systems to Retrofit CHP Plants in Wastewater Treatment Stations, J. sustain. dev. energy water environ. syst., 1(4), pp 352-374, 2013, DOI: http://dx.doi.org/10.13044/j.sdewes.2013.01.0027 ABSTRACT Wastewater treatment stations take advantage of the biogas produced from sludge in anaerobic digesters to generate electricity (reciprocating gas engines) and heat (cooling water and engine exhaust gases). A fraction of this electricity is used to operate the plant while the remaining is sold to the grid. Heat is almost entirely used to support the endothermic anaerobic digestion and a minimum fraction of it is rejected to the environment at a set of fan coolers. This generic description is applicable to on-design conditions. Nevertheless, the operating conditions of the plant present a large seasonal variation so it is commonly found that the fraction of heat rejected to the atmosphere increases significantly at certain times of the year. Moreover, the heat available in the exhaust gases of the reciprocating engine is at a very high temperature (around 650 ºC), which is far from the temperature at which heat is needed for the digestion of sludge (around 40 ºC in the digesters). This temperature difference offers an opportunity to introduce an intermediate system between the engines and the digesters that makes use of a fraction of the available heat to convert it into electricity. An Organic Rankine Cycle (ORC) with an appropriate working fluid is an adequate candidate for these hot/cold temperature sources. In this paper, the techno-economic effect of adding an Organic Rankine Cycle as the intermediate system of an existing wastewater treatment station is analysed. On this purpose, different working fluids and system layouts have been studied for a reference wastewater treatment station giving rise to optimal systems configurations. The proposed systems yield very promising results with regard to global efficiency and electricity production (thermodynamically and economically). KEYWORDS CHP, ORC, Organic Rankine Cycle, Wastewater treatment station, Cogeneration INTRODUCTION Wastewater treatment stations, which produce biogas by processing sludge (organic matter) in anaerobic digesters, constitute an important source of biofuels worldwide as confirmed by the fact that 15% of the total production of biogas in Europe in 2007 was expected to be produced at such facilities [1]. This biogas fuel is usually employed to generate electricity in reciprocating engines (spark-ignition engines specifically adapted for biogas operation) in order to supply the plant’s internal demand of electricity and, if possible, export the excess energy to the grid. Then, the heat rejected from the engine * Corresponding author
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 353 (either in the form of hot cooling water or flue gases) is used to support the anaerobic digestion of organic matter [2]. The singular features of the fuel and the simultaneous production of heat and power pose two main challenges to these installations: (i) to be qualified as high efficiency co-generators in order to have access to the beneficial electricity sale conditions [3], and (ii) to eliminate certain impurities that are inevitably found in the biogas yield, compromising the mechanical integrity of the system (engines and others equipment). Volatile sulphur compounds and siloxanes are some of the species whose concentrations must be controlled [4, 5]. From an energy management standpoint, it is observed that the amount of heat required for sludge digestion and the operating conditions of the CHP plant present substantial seasonal variations that make it common that the fraction of heat rejected to the atmosphere (i.e. excess heat) increases significantly at certain times of the year. On top of this mismatch between available waste heat from the engine and heat demand from the digesters, a large temperature difference is found between the temperature at which heat is available in the engine exhaust gases (in the order of 650 ºC) and the operating temperature of the digestion process (around 40 ºC). Such temperature difference makes it possible to introduce an intermediate system between the engines and the digesters to make use of a fraction of the available heat and convert it into electricity, therefore increasing the efficiency of the system. An Organic Rankine Cycle (ORC) with an adequate fluid selection is a candidate for the hot/cold temperature source/sink of the reference CHP and WWT plant [6, 7]. These ORC systems are used in a variety of low and medium temperature applications such as geothermal [8, 9], waste heat recovery [10-12] and biomass [13, 14], where the performance of the cycle mainly depends on the working fluid of choice [10, 15]. In this regard, a number of working fluids as hydrocarbons and refrigerants have been studied [12, 16] even if only a few of them are commercially available nowadays. Further to the previous works referred above and for the particular case of waste heat recovery from internal combustion engines, an ample discussion of the different technologies available can be found in reference [17] for the automotive industry and in reference [18] for the case of heavy-duty stationary diesel generators. In the latter group, and concerning system integration, Vaja and Gambarotta [19] discuss different integration schemes between stationary diesel engines and bottoming Organic Rankine Cycles: recuperative versus non-recuperative cycles that recover heat from the exhaust gases only or also from the cooling water are explored. The afore listed works consider bottoming Rankine cycles working on organic species, on steam or on even more original working fluids like in the Kalina cycle (water-ammonia mixture). Concerning the former group (organic), a very complete analysis is provided by Maizza and Maizza [20], who screen twenty different species (mostly refrigerants) in order to select the candidate with the most interesting properties from the cycle efficiency standpoint. In the same sense, Quoilin et al. [21] provide a review of the many different organic fluids studied to date, along with the application and temperature ranges in which they have been considered. Nevertheless, amongst the works that concentrate on characterising the behaviour of organic working fluids, that by Angelino and Colonna must be acknowledged for its completeness and technical consistency [22]. Finally, the work by Gewald et al. [23] on the assessment of waste heat recovery from landfill-gas engines must be noted as it has many similarities with the present article. This very recently published research work discusses the interest of recuperating the waste heat carried by flue gases at a power plant comprising fifteen reciprocating engines
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 354 operating on landfill gas. This recuperated energy is then employed by an organic Rankine cycle to produce additional electricity. Nevertheless, in spite of both plants being fired by biogas coming from municipal waste (solid waste in ref. [23] and wastewater in the present article) there are substantial differences between both facilities that make it quite difficult to exchange the conclusions between one another. In this work, the incorporation of an Organic Rankine Cycle into an existing wastewater treatment station, a combination that has not been previously studied in detail to the authors’ best knowledge, is analysed. To this aim, the retrofit of the CHP plant is thoroughly studied by considering new operating modes and adaptation of certain components with the goal of maintaining the digesters’ optimal conditions for most of the operating range of the plant. The analysis yields promising results with regard to energy and economic performance. It is hence clear that the most notable singularity of the plant analysed in this work and reference [23] is the fact that the exhaust gases from the engine are released to the atmosphere at the solid waste plant whereas they supply heat to the process at a wastewater treatment plant. In other words, the incorporation of an additional bottoming system is unconstrained in the first case and constrained in the second one. These issues will be covered throughout the article. FACILITY DESCRIPTION Description The reference wastewater treatment station is located in Andalusia, South of Spain. A general overview showing how the processes are organised is shown in Figure 1. In the primary sedimentation stage, wastewater is conveyed from the collecting well to the primary sedimentation tanks where heavy solids settle by gravity whilst oil, grease and lighter solids float on the surface. In the secondary treatment, biological processes eliminate the matter suspended or dissolved in the wastewater. A final tertiary treatment provides the effluent with the specifications required by the water quality regulations applied to the market under consideration. Figure 1. Wastewater treatment processes In the wastewater station under study, sludge generated in the primary and secondary treatments is homogenised prior to the injection of ferric chloride to abate sulphur compounds by precipitation/scavenging. Then, sludge is conveyed to the anaerobic digesters where they are stored for twenty eight days at temperatures within a very narrow range in order to ensure that the rate at which the microorganisms break down the biodegradable matter is highest. Finally, sludge is dried by centrifugation and sent for final storage/disposal. In the reference plant, the anaerobic digestion of sludge takes place in three reactors (digesters) with approximated volumes 7,400, 10,500 and 21,000 m3. Within these
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 355 vessels, biogas is generated with an average composition of 60% methane and 35% CO2 (volume percentage) and a mean Lower Heating Value (LHV) of 23 MJ/Nm3. Nevertheless, special attention must be paid to the siloxanes and volatile sulphur compounds (VSCs) that are also present in the biogas inasmuch as they can seriously damage the engines and heat exchangers even if found in very small quantities [4, 24]. As indicated before, there are different technologies for the abatement of VSCs and siloxanes [4, 25] though, in the context of this work, a treatment with ferric chloride ensures that the concentration of hydrogen sulphur in the clean biogas is below 20 ppm. The CHP power plant comprises three engine generator sets that typically operate on clean biogas even though biogas/natural gas blends can also be used. Tables 1 and 2 present the main specification of the engines and their part-load performance as provided by the manufacturer. Table 1. Engine specifications at rated conditions Model GUASCOR FGLD 480/80 Configuration V-16 Shaft speed [rpm] 1,500 rpm Brake/ Electrical Power (ISO conditions) 690/667 kW Heat input [kW] 1,860 Heat rejected by cooling water [kW] 548 Heat rejected by oil cooler [kW] 81 Heat rejected by intercooler [kW] 61 Heat rejected by radiation [kW] 43 Intake air flow [kg/h] 3,670 Exhaust gas flow [kg/h] 3,810 Electric efficiency [%] 35.1 Table 2. Part-load performance of the engine Load 100% 75% 50% Electrical power [kWel] 667 495 330 Exhaust temperature [ºC] 404 379 354 Efficiency [-] 0.351 0.308 0.264 Heat from cooling water [kWt] 548 496 445 The CHP plant, shown in Figure 2, includes the following equipment and subsystems in addition to the generator sets: Figure 2. Layout of the reference CHP plant
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 356 An intermediate closed water loop to convey heat from engines to digesters. Plate heat exchangers for low temperature heat recovery from engine cooling jackets and lube oil system (PHXi). Shell and tube heat exchangers for high temperature heat recovery from the exhaust gases (HXi). Plate heat exchangers for low temperature heat supply to the anaerobic digesters (PHXDi) Pressurised storage and supply of biogas for the engines. Air coolers to reject excess heat from the water loop CHP performance The design goals of the current CHP installation are as follows: Highest utilisation of biogas. Temperature of digesters close to optimum value (for highest biogas production rate) across the entire range of operation. Highest net electricity delivered to the grid during peak hours. Under these considerations, the default operating mode of the CHP plant is based on running two engines only in ordinary market conditions and starting-up the third one during peak price periods. Table 3 presents some relevant performance parameters of the CHP plant. The “design” values correspond to the predicted operating conditions of the original project (i.e. the rated operating conditions) whereas “operation 2007” stands for mean deviation from the former values as obtained from the operation of the digesters in year 2007 (there were no data available for the rest of the equipment). Table 3. Rated vs. real performances of the CHP installation Design Operation 2007 Hot side Cold side Hot side Cold side Engine cooling jackets Flow [m3/h] 67.2 59.9 - - Inlet Temperature [ºC] 85 70 - - Exhaust Temperature [ºC] 78 77.8 - - Digester A Flow [m3/h] 61 25.5 -26.2% 96.1% Inlet Temperature [ºC] 81.8 59 -18.1% 3.4% Exhaust Temperature [ºC] 78 68 -17.3% -5.9% Digester B Flow [m3/h] 59.9 48.8 -24.9% -9.8% Inlet Temperature [ºC] 81.8 59 -18.1% 2.5% Exhaust Temperature [ºC] 74.4 68 -16.7% -5.7% Digester C Flow [m3/h] 59.8 90.7 -24.7% 34.5% Inlet Temperature [ºC] 81.8 59 -18.1% 2.5% Exhaust Temperature [ºC] 68 68 -7.2% -5.6% The values in Table 3 confirm that the performances obtained in real operating conditions differ substantially from the corresponding design values, both in flow and temperature. As a general rule of thumb, it is observed that there is a trend to reduce the mass flow rate of water in the hot side of the water loop and also to maintain the temperature drop of this hot water though at a lower average temperature level. In other words, the temperatures of hot water entering and leaving the heat exchangers of digesters A, B and C are lower than the rated values even though the temperature drops are at their design values (just a slight deviation with respect to this general pattern is observed in digester C).
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 357 With respect to the cold side, the general pattern shows that the mass flow rate of water is largely increased with respect to the rated value whereas the temperature drop decreases: higher inlet temperature and lower outlet temperature at the cold side of heat exchangers A, B and C. In conclusion, the differences observed in Table 3 suggest that the rated conditions are probably wrongly selected (the plant is not sized correctly) or, conversely, that there is room for increasing the efficiency of the plant by taking advantage of the unused waste heat from the biogas engines. This is further assessed below. The annual energy balance for year 2007 is presented in Figures 3 and 4 where the main energy consumptions of the wastewater treatment station, the energy balances in the CHP plant and some indicators of the cogeneration power block are given [26]. The global electricity demand was of 15.56 GWhel, the annual electricity production 10.99 GWhel and the biogas generated in terms of energy capacity 32.74 GWht. Figure 3 presents the monthly variation of the energy balance in the existing wastewater treatment station (key symbols are W for the production of electricity, Q for the recuperated heat energy from the engine and F for the primary/chemical energy in the biogas fuel produced by the anaerobic digesters). Figure 3. Monthly variation of energy parameters in the wastewater treatment station (2007) The indicators used to characterize the cogeneration are equivalent electric efficiency (EEE) [3] and energy utilization factor (EUF) [26], defined as follows: ( ) (1) ( ⁄) (2) Where W, F and Q stand for electricity, fuel primary energy (heat input) and used waste heat (useful process heat) respectively. The global values of EEE and EUF were 65.3% and 67.4% respectively. The current cogeneration facility complies with the requirements to be certified as a highly efficient cogeneration plant, which is set by the minimum EEE specified by the applicable legislation depending on the characteristics of the CHP unit [3]; for wastewater biogas with internal combustion engines this value is 0.5 as defined in the Royal Decree RD 661/2007 [3]. The classification is not dependent on the current moratorium of electricity generation for special regime in Spain. Nevertheless, in spite of this reasonably good performance, there is still room for performance
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 358 enhancement as suggested by the aforementioned analysis of the operating modes and data. Amongst the potential actions to be taken, the following can be cited: Operate with three engines running at 95% continuous rating. This is possible given the current production of biogas. Implement a control system to monitor the heat exchangers and, ultimately, the flow of hot water to each digester in order to maintain temperatures closer to the design values. Upgrade the air coolers to avoid excessive cooling of water (it currently works 10 ºC below the design point with an outlet temperature of 60 ºC). Add an intermediate system to take advantage of the temperature difference between the engine’s exhaust gas temperature and the operating temperature of the digesters. The incorporation of new operating strategies and a new intermediate system based on Organic Rankine Cycles to recuperate surplus energy from the engine exhaust gases is analysed in the next sections. ORC PLANT The previous section has presented the most relevant characteristics of the existing CHP plant along with a discussion on the potential for efficiency improvement if changes in the operational modes and/or in the plant layout were incorporated. In the latter regard, the integration of an Organic Rankine Cycle (ORC) into the existing CHP plant is now proposed. Such a cycle is suitable for facilities operating at moderate to low temperatures (at turbine inlet), to which they adapt by an appropriate selection of the working fluid. Model description The model of the CHP plant is implemented in Engineering Equation Solver (EES) [27]. It consists of a lumped volume approach where mass and energy conservation equations are applied to each component of the plant. The latter are presented below: Heat exchangers: (3) Turbine (ORC): (4) Pumps: (5) In addition to heat and mass balances, the performance of heat exchangers is modelled by means of the ε-NTU method: (6) ( ) (7) ( ) (8)
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 359 where C is the heat capacity (specific heat at constant pressure times mass flow rate), NTU the number of transfer units and U is a global heat transfer coefficient evaluated with Gnielinski’s correlation [28]: ( )( ) ( ) ( ) (9) ( ) (10) (11) ( ) ( ) ( ) (12) where f is the friction factor coefficient that can be determined by Eq. (10) for smooth surfaces and LMTD is the logarithmic mean temperature difference. Fouling effects within the heat exchangers are also accounted for as indicated by the TEMA standard code, Table 4 [29]. Table 4. Fouling resistances for the fluids in the plant [29] Fluid Fouling resistance [m2K/W] Engine exhaust gases 0.001-0.002 Water (non-demineralised) 0.0001-0.0002 Industrial organic heat transfer media 0.0001-0.0002 The performances of the engine at rated and partial loads are summarized in Tables 1 and 2, whose data are later corrected to account for variable ambient conditions as per the following equations taken from the ISO 3046 standards [30]: (13) ( ) (14) [( ) ( )⁄ ][ ⁄ ] (15) ( ⁄ ) (16) where Ps stands for saturation pressure at the corresponding temperature. The reference conditions for pressure P, temperature T and relative humidity φ in Eqs. (13-16) are 100 kPa, 298 K and 30% respectively [30]. ORC plant performance In the course of the analysis, which is performed with a lumped volume model of the type described in Section 3.1, recuperative and non-recuperative cycle layouts are considered and the selection of the most appropriate working fluid is done on the basis of previous works by the authors: in combined cycles with gas turbines [6, 11], new concepts of solar plants [10] or compound systems with high temperature fuel cells [31]. In effect, the performance of these systems is strongly dependent on the thermo physical
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 360 properties of the working fluid [32] and, following this rationale, the fluids considered in this work are Toluene, Cyclohexane, R245fa and Isobutane, whose critical conditions and stability limits are presented in Table 5 [10, 15]. It gives the critical pressure and temperature, the maximum operating pressure, the maximum temperature as saturated vapour and the maximum temperature for the fluid stability. Table 5. Temperature and pressure limits for the fluids under analysis Fluid Tcrit [K] Pcrit [bar] Tmaxsat [K] Pmax [bar] Tlim [K] Toluene 591.75 41.3 569.05 31.2 671.95 Cyclohexane 553.65 40.8 536.05 32.7 560.75 R245fa 427.25 36.5 403.05 23.3 433.65 Isobutene 407.85 36.4 380.05 25.5 413.35 Figure 4 presents the ORC recuperative layout and the T-s diagram. The recuperative layout is feasible when organic (dry) fluids are used since they are found in superheated state at the turbine exhaust section. Hence, as a general rule of thumb, it can be considered that ORC recuperative cycles are of interest when the temperature difference between the turbine exhaust and the pump impulse section is above 50 ºC (if not, the added cost of this device is not compensated by the increased efficiency) [10, 11]. Figure 4. ORC recuperative layout and T-s diagram Table 6 presents the specifications of the reference ORC cycle used for comparison (ΔTrec is the pinch point in the recuperator). Table 6. ORC cycle parameters Value ηt 0.85 ηp 0.8 Ti [ºC] Depends on the ORC fluid Tc [ºC] Depends on the month (Reference June 30) ΔTrec [ºC] 10 The bottoming cycle global efficiency (BC) results of the combined effects on the efficiencies of the Heat Recovery Vapour Generator (HRVG) and the ORC cycle: (17)
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 367 The information presented in Table 10 is shown graphically in Figure 10 where the scattering of specific costs coming from different references is more visible. As indicated by Walsh and Thornley [42], logarithmic functions replicate the behaviour of specific cost vs. power output for these power systems (i.e. provide the best curve fitting to the data in Table 10). Thus, the fitting given by the solid line and equation shown in Figure 10 is used henceforth. Figure 10. Specific capital cost vs. capacity (power output) of the system. Curve fitting. Due to the inevitable uncertainty associated with the specific cost, the economic appraisal of the plant is based on a sensitivity analysis of this variable. To this aim, the following economic assumptions are defined: Financial scenario presented in Table 11. Market prices for the electricity exported to the grid are determined from the applicable Spanish legislation. The recent RDL 9/2013, 12th of July of 2013 [44], changes drastically the special regimen electricity production although it maintains electricity tariffs for a transient period. Table 11. Main assumptions of the financial and economic analysis Installed capacity ORC unit [kWel] 120.1 Lifetime [years] 15 Discount rate [%] 10 Inflation [%] 2.5 Taxes [%] 30 Interest rate (loan) [%] 10 Loan payback time [years] 15 Debt share (loan/total cost) [%] 50 Amortisation [%] 100 Electricity sale price for cogeneration, [€/kWh] 0.16061 O&M cost annual [% initial cost] 1.5 Capacity factor [%] 90 Figure 11 presents the effect of varying the cost of the ORC skid on the plant’s NPV and IRR. It is shown that, in spite of the expected negative effect of increasing the ORC cost, high Net Present Values are still obtained even for high variations of this parameter (i.e. high uncertainty). Therefore, the benefits derived from retrofitting the conventional reference plant are ensured even if strong deviations from the normal economic scenario were to take place. y = 5,556,2·x-0,1264 R² = 0,6293 0 1000 2000 3000 4000 5000 6000 7000 0 500 1000 1500 2000 2500 Capital cost [€/kW] Output [kWel]
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 368 Figure 11. Sensitivity analysis to the capital cost of the ORC system In addition to the specific cost of the ORC system, there are other parameters in Table 11 that affect the economic performance of the retrofitted plant and whose values are difficult to estimate. To account for this, the authors have deemed it convenient to perform a “Monte Carlo” analysis incorporating the uncertainties shown in Table 12 below. Table 12. Sensitivity parameters for the Monte Carlo analysis Parameter Mean value Uncertainty Specific cost ORC [€/kWel] 3033 ± 750 Capacity factor [%] 90 ± 5 Sale price of electricity, [€/kWh] 0.16061 ± 0.025 Inflation [%] 2.5 ± 0.5 Interest rate [%] 10 ± 2.5 The results obtained from running ten thousand cases with the restrictions of Table 12 are shown in Figure 12. This figure shows the number of cases (percentage) for which the NPV and IRR take the values given horizontally. For the Net Present Values, the highest probability corresponds to the interval from 550 k€ to 625 k€ (cumulative probability in the order of 50%), whereas this most probable Internal Rate of Return is in the order of 45 to 60% (cumulative probability over 50%). Figure 12. Net Present Value resulting from the Monte Carlo analysis 30% 40% 50% 60% 70% 80% 90% 400.000,0 € 450.000,0 € 500.000,0 € 550.000,0 € 600.000,0 € 650.000,0 € 700.000,0 € 2000 2500 3000 3500 4000 IRR NPV ORC cost [€/kW] NPV IRR
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 369 CONCLUSIONS This work analyses the retrofitting of a CHP in a wastewater treatment plant with an Organic Rankine Cycle. The following considerations should be highlighted from this analysis: The introduction of an adequate Organic Rankine Cycle to take advantage of the temperature difference between the available heat and the anaerobic digestion process allows an increase of the recuperated heat in the CHP plant. For the reference wastewater treatment station the retrofitting, combined with an adequate change in the operation mode of the existing engines, increases the power production while maintains the high efficiency cogeneration qualification that brings about complementary incentives and trading conditions. Two different CHPORC integrations were selected for the retrofitting: a recuperative ORC plant with toluene working with superheated vapour (31.3 bar, 320 ºC) and a non-recuperative cycle with R245fa working with saturated vapour (23.3 bar, 129.9 ºC). The toluene ORC plant was selected because its high performance characteristics while the R245fa ORC was selected because its commercial development, higher stability, lower toxicity and flammability and condenser pressure above the atmospheric. The integration of both layouts was designed with the objective of maintaining the temperatures of the digesters at their rated values. For this reason in layout 1, with toluene, the Heat Recovery Vapour Generator (HRVG) is placed at the exhaust of the engines and a set of air coolers maintain the temperature in the digesters while in the layout 2, with R245fa, the HRVG is installed downstream of the digesters heat exchangers. The proposed retrofitted CHP & ORC plants yield an average efficiency for the reference year 2007 of 38.7% for the layout1 and 36.5% for the layout 2. The change in the operating mode for the retrofitted CHP plant produces more electricity from the existing engines, changing the net electricity balance of the plant from purchase to sale. The equivalent annual electricity savings totalize 7880.8 MWh for the layout 1 with toluene and 6811.4 MWh for the layout 2 with R245fa. The R245 layout would be the preferred option because only minor modifications in the existing power plant are required. The plant with R245fa is simpler (absence of deaerator and recuperator) with reduced investment and probability of problems in the plant operation. Regarding the working fluid, it has higher stability and lower toxicity and flammability. In addition there is ORC technology currently operating with R245fa; i.e. it is off-the-shelf technology. The economic analysis confirms the interest of the proposed retrofitting. The effect of the ORC cost is relatively small due to the little economic weight of the investment compared with the change in the electricity production of the whole CHP plant. Therefore, the benefits derived from retrofitting the conventional reference plant are ensured even if strong deviations from the normal economic scenario were to take place. A Monte Carlo analysis accounting for uncertainty in
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 370 determining the financial and economic scenario confirms the robustness (generality) of this conclusion. For the Net Present Values, the highest probability corresponds to the interval from 550 k€ to 625 k€ (cumulative probability in the order of 50%), whereas the most probable Internal Rate of Return is in the order of 45 to 60% (cumulative probability over 50%). NOMENCLATURE C - heat capacity, kW/ºC EEE - equivalent electric efficiency, % EUF - energy utilisation factor, % F - Fuel Heat Input, kWh H - enthalpy, kJ/kg LCOE - levelized cost of electricity LHV - Lower Heating Value, kJ/kg m - mass flow, kg/s NTU - number of transfer units P - pressure, kPa Q - heat, kWh T - temperature, ºC U - global heat transfer coefficient, kW/ºC W - electricity, kWh Greek symbols - effectiveness, % - thermal efficiency, % Subscripts c - condenser e - evaporator el - electric CF - cold flow HF - hot flow i - turbine inlet max - maximum p - pump r - reference ambient conditions rec - recuperative cycle s - isentropic t - turbine or thermal x - current ambient conditions Abbreviations AERO - aero-refrigerator CHP - Combined Heat and Power plant DIG - digester EES - Engineering Equation Solver HRVG - Heat Recovery Vapour Generator HXi - shell and tube heat exchangers for heat recovery at engine exhaust ICE - Internal Combustion Engine
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 371 ORC - Organic Rankine Cycle PHXi - plate heat exchangers (cooling jackets) PHXDi - plate heat exchangers (digesters) VSC - volatile sulphur compounds REFERENCES 1. European Biomass Association Biogas roadmap, www.aebiom.org, [Accessed: Jan-2012] 2. Abbasi T., Tauseef SM., Abbasi SA., Biogas Energy, Springer, pp 11-23, 2012., http://dx.doi.org/10.1007/978-1-4614-1040-9_2 3. Royal Decree 661/2007, dated 25 May, regulating the production of electricity in the special regime. (BOE number 126, dated 26 May 2007) 4. Rasi S, Läntelä J, Rintala J. Trace compounds affecting biogas energy utilisation – A review. Energy Conversion and Management, 52, pp 3369-3375, 2011., http://dx.doi.org/10.1016/j.enconman.2011.07.005 5. Matsui T, Imamura S. Removal of siloxane from digestion gas of wastewater sludge. Bioresource Technology, 101, pp 29-32, 2010., http://dx.doi.org/10.1016/j.biortech.2009.05.037 6. Chacartegui R, Sánchez D, Muñoz de Escalona JM, Sánchez T. Alternative ORC bottoming cycles FOR combined cycle power plants. Applied Energy, 86, pp 2162-2170, 2009., http://dx.doi.org/10.1016/j.apenergy.2009.02.016 7. Chen, DH., Goswami Y., Stefanakos EK., A review of thermodynamic cycles and working fluids for the conversion of low-grade heat. Renewable and Sustainable Energy Reviews, 14, pp 3059-3067, 2010., http://dx.doi.org/10.1016/j.rser.2010.07.006 8. Guzovic Z., Loncar D., Ferdelj N., Possibilities of electricity generation in the Republic of Croatia by means of geothermal energy. Energy, 35, pp 3429-3440, 2010., http://dx.doi.org/10.1016/j.energy.2010.04.036 9. Franco A. Power production from a moderate temperature geothermal resource with regenerative Organic Rankine Cycles. Energy for Sustainable Development, 15, pp 411-419, 2011., http://dx.doi.org/10.1016/j.esd.2011.06.002 10. Chacartegui R., Muñoz de Escalona JM., Sánchez D., Monje B., Sánchez T., Alternative cycles based on carbon dioxide for central receiver solar power plants. Applied Thermal Engineering, 31, pp 872-879, 2011., http://dx.doi.org/10.1016/j.applthermaleng.2010.11.008 11. Muñoz de Escalona JM., Sánchez D., Chacartegui R., Sánchez T., Part-load analysis of gas turbine & ORC combined cycles. Applied Thermal Engineering, 36, pp 63-72, 2012., http://dx.doi.org/10.1016/j.applthermaleng.2011.11.068 12. Wang EH., Zhang HG., Fan BY., Ouyang MG., Zhao Y., Mu QH., Study of working fluid selection of organic Rankine cycle (ORC) for engine waste heat recovery. Energy, 36, pp 3406-3418, 2011., http://dx.doi.org/10.1016/j.energy.2011.03.041 13. Schuster A., Karellas S., Kakaras E., Spliethoff H., Energetic and economic investigation of Organic Rankine Cycle applications. Applied Thermal Engineering, 29, pp 1809-1817, 2009., http://dx.doi.org/10.1016/j.applthermaleng.2008.08.016
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 372 14. Drescher U., Bruggeman D., Fluid selection for the Organic Rankine Cycle (ORC) in biomass power and heat plants. Applied Thermal Engineering, 27, pp 223-228, 2007., http://dx.doi.org/10.1016/j.applthermaleng.2006.04.024 15. Aljundi IH., Effect of dry hydrocarbons and critical point temperature on the efficiencies of organic Rankine cycle. Renewable Energy, 36, pp 1196-1202, 2011., http://dx.doi.org/10.1016/j.renene.2010.09.022 16. Quoilin S., Declaye S., Bertrand F., Tchanche BF., Lemort V., Thermo-economic optimization of waste heat recovery Organic Rankine Cycles. Applied Thermal Engineering, 31, pp 2885-2893, 2011., http://dx.doi.org/10.1016/j.applthermaleng.2011.05.014 17. Saidur R., Rezaei M., Muzammil WK., Hassan MH., Paria S., Hasanuzzaman M., Technologies to recover exhaust heat from internal combustion engines. Renewable and Sustainable Energy Reviews, 16, pp 5649-5659, 2012., http://dx.doi.org/10.1016/j.rser.2012.05.018 18. Bombarda P., Invernizzi C.M., Pietra C., Heat recovery from Diesel engines: A thermodynamic comparison between Kalina and ORC cycles. Applied Thermal Engineering; 30, pp 212-219, 2010., http://dx.doi.org/10.1016/j.applthermaleng.2009.08.006 19. Vaja I., Gambarotta A., Internal Combustion Engine (ICE) bottoming with Organic Rankine Cycles (ORCs). Energy, 35, pp 1084-1093, 2010., http://dx.doi.org/10.1016/j.energy.2009.06.001 20. Maizza V., Maizza A., Unconventional working fluids in Organic-Rankine cycles for waste energy recovery systems. Applied Thermal Engineering, 21, pp 381-390, 2001., http://dx.doi.org/10.1016/S1359-4311(00)00044-2 21. Quiukun S., Declaye S., Tchanche B.F., Lemort V., Thermo-economic optimization of waste heat recovery Organic Rankine Cycles. Applied Thermal Engineering, 31, pp 2885-2893, 2011., http://dx.doi.org/10.1016/j.applthermaleng.2011.05.014 22. Angelino G., Colonna P., Multicomponent Working Fluids for Organic Rankine Cycles (ORCs). Energy, 23, pp 449-463, 1998., http://dx.doi.org/10.1016/S0360-5442(98)00009-7 23. Gewald D., Siokos K., Karellas S., Spliethoff H., Waste heat recovery from a landfill gas-fired power plant. Renewable and Sustainable Energy Reviews, 16, pp 1779-1789, 2012., http://dx.doi.org/10.1016/j.rser.2012.01.036 24. Kymäläinen M., Lähde K., Arnold M., Kurola JM., Romantschuk M., Kautola H., Biogasification of biowaste and wastewater sludge e Measurement of biogas quality. Journal of Environmental Management; 95, pp 122-127, 2012., http://dx.doi.org/10.1016/j.jenvman.2011.01.003 25. Osorio F., Torres J.C., Biogas purification from anaerobic digestion in a wastewater treatment plant for biofuel production, Renewable Energy, 34, pp 2164-2171, 2009., http://dx.doi.org/10.1016/j.renene.2009.02.023 26. EU Directive 2004/8/EC. On the promotion of cogeneration based on a useful heat demand in the internal energy market and amending Directive 92/42/EEC. (2004) Official Journal of the European Union of 11 February 2004. 27. Engineering Equation Solver, http://www.fchart.com/ees/, Accessed: [10-Feb-2013]
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 373 28. Incropera F.P., DeWitt D.P., Fundamentals of Heat and Mass Transfer. 3rd Ed., Wiley, NY, 1990. 29. Standard of tubular exchanger manufacturers association (TEMA), ninth edition; 2007. 30. ISO 3046-1. Reciprocating internal combustion engines - performance; 2002. 31. Sánchez D., Muñoz de Escalona J.M., Monje B., Chacartegui R., Sánchez T., Preliminary analysis of compound systems based on high temperature fuel cell, gas turbine and Organic Rankine Cycle. Journal of Power Sources; 196, pp 4355-4363, 2011., http://dx.doi.org/10.1016/j.jpowsour.2010.07.060 32. Kuo C.-R., Hsu S.-W., Chang K.-H., Wang C.-C., Analysis of a 50 kW organic Rankine cycle system, Energy, 36, pp 5877-5885, 2011., http://dx.doi.org/10.1016/j.energy.2011.08.035 33. Kang S.H., Design and experimental study of ORC (organic Rankine cycle) and radial turbine using R245fa working fluid. Energy, 41, pp 514-524, 2012., http://dx.doi.org/10.1016/j.energy.2012.02.035 34. Capstone Clean Cycle brochure, Capstone Turbine Corporation, available at http://www.horizonpowersystems.com/Amend/images/pdfs/CapstoneCleanCycle12 1kW_331062B_lowres.pdf, Accessed: [10-Jul-2013] 35. Infinity IT10 ORC brochure, Infinity Turbine, available at http://www.infinityturbine.com/pdf/Infinity_Turbine_Brochure.pdf, Accessed: [01-Jun-2013] 36. Tchanche B.F., Quoilin S., Declaye S., Papadakis G., Lemort V., Economic Feasibility Study of a Small Scale Organic Rankine Cycle System in Waste Heat Recovery Application. Proceedings of 10th Biennial Conference on Engineering Systems Design and Analysis (ESDA2010), July 12–14th, Istanbul, Turkey, pp 249-256, 2010., http://dx.doi.org/10.1115/ESDA2010-24828 37. Invernizzi C, Iora P, Silva P. Bottoming micro-rankine cycles for micro-gas turbines. Applied Thermal Engineering; 27, pp 100-110, 2007., http://dx.doi.org/10.1016/j.applthermaleng.2006.05.003 38. Peretti I. Application of ORC units in sawmills, Technical - economic considerations, 2008, Paper Turboden, http://www.turboden.eu/en/public/downloads/08A03722_paper_turboden_segherie. pdf, Accessed: [03-Jun-2013] 39. Bruno J.C., López-Villada J., Letelier E., Romera S., Coronas A., Modelling and optimisation of solar organic rankine cycle engines for reverse osmosis desalination. Applied Thermal Engineering; 28, pp 2212-2226, 2008., http://dx.doi.org/10.1016/j.applthermaleng.2007.12.022 40. Obernberger I., Thonhofer P., Reisenhofer E., Description and evaluation of the new 1,000 kWel Organic Rankine Cycle process integrated in the biomass CHP plant in Lienz, Austria. Euroheat & Power, 10, pp 1-17, 2002. 41. Tchanche B.F., Lambrinos Gr., Frangoudakis A., Papadakis G., Lowgrade heat conversion into power using organic Rankine cycles – A review of various applications. Renewable and Sustainable Energy Reviews, 15, pp 3963-3979, 2011., http://dx.doi.org/10.1016/j.rser.2011.07.024
Journal of Sustainable Development of Energy, Water and Environment Systems Year 2013 Volume 1, Issue 4, pp 352-374 Page 374 42. Walsh C., Thornley P., The environmental impact and economic feasibility of introducing an Organic Rankine Cycle to recover low grade heat during the production of metallurgical coke. Journal of Cleaner Production, 34, pp 29-37, 2012., http://dx.doi.org/10.1016/j.jclepro.2011.12.024 43. Walsh C., Thornley P., Cost effective greenhouse gas reductions in the steel industry from an Organic Rankine Cycle. Chemical Engineering Transactions, 25, pp 905-910, 2011., http://dx.doi.org/DOI:10.3303/CET1125151 44. Royal Decree 9/2013, dated 12 July, Measures for the financial stability of the electricity system (BOE number 167, dated 12 July 2013) Paper submitted: 19.07.2013 Paper revised: 30.08.2013 Paper accepted: 05.09.2013