Design of a Thomson scattering diagnostic for the SMall Aspect Ratio Tokamak (SMART)

Kaur, M.; Diallo, A.; LeBlanc, B.; Segado Fernández, Jorge; Viezzer, Eleonora; Huxford, R. B.; Mancini, Alessio; Cruz Zabala, Diego José; Podestà, M.; Berkery, J. W.; García Muñoz, Manuel

Abstract

We describe the design of a Thomson scattering (TS) diagnostic to be used on the SMall Aspect Ratio Tokamak (SMART). SMART is a spherical tokamak being commissioned in Spain that aims to explore positive triangularity and negative triangularity plasma scenarios at a low aspect ratio. The SMART TS diagnostic is designed to operate at high spatial resolution, 6 mm scattering length in the low-field side and 9 mm in the high-field side regions, and a wide dynamic range, electron temperature from 1 eV to 1 keV and density from 5 × 1 0 18 m − 3 to 1 × 1 0 20 m − 3 , to resolve large gradients formed at the plasma edge and in the scrape-off layer (SOL) under different triangularities and low aspect ratios. A 2 J @ 1064 nm laser will be used that is capable of operating in the burst mode at 1, 2, and 4 kHz to investigate fast phenomena and at 30 Hz to study 1 s (or more) long discharges. The scattered light will be collected over an angular range of 60 ° - 120 ° from 28 spatial points in the midplane covering the entire plasma width and the outer midplane SOL. Each scattering signal will be spectrally resolved on five wavelength channels of a polychromator to obtain the electron temperature measurement. We will also present a method to monitor in situ laser alignment in the core during calibrations and plasma operations.

Full text

Thomson Scattering diagnostic for SMART Design of a Thomson scattering diagnostic for the SMall Aspect Ratio Tokamak (SMART) M. Kaur,1A. Diallo,1B. LeBlanc,1J. Segado-Fernandez,2E. Viezzer,2R. B. Huxford,3A. Mancini,2D. J. Cruz-Zabala,2M. Podesta,1, 4 J. W. Berkery,1and M. Garcia-Muñoz2 1)Princeton Plasma Physics Laboratory, Princeton, NJ 08540, USA. 2)Department of Atomic, Molecular and Nuclear Physics, University of Seville, Seville, Spain. 3)RBH Optics, Burgess Hill, West Sussex RH15 8HL, United Kingdom 4)Presently at Ecole Polytechnique Fédérale de Lausanne, Swiss Plasma Center, CH-1015 Lausanne, Switzerland. (*Electronic mail: [email protected]) We describe the design of a Thomson scattering (TS) diagnostic to be used on the SMall Aspect Ratio Tokamak (SMART). SMART is a spherical tokamak being commissioned in Spain that aims to explore positive triangularity (PT) and negative triangularity (NT) plasma scenarios at a low aspect ratio. The SMART TS diagnostic is designed to operate at high spatial resolution, 6 mm scattering length in the low-field side (LFS) and 9 mm in the high-field side (HFS) regions, and a wide dynamic range, electron temperature from 1 eV to 1 keV and density from 5 ×1018 m−3to 1 ×1020 m−3, to resolve large gradients formed at the plasma edge and in the scrape-off layer (SOL) under different triangularities and low aspect ratios. A 2 Joule @1064 nm laser will be used that is capable of operating in the burst mode at 1 kHz, 2 kHz, and 4 kHz to investigate fast phenomena and at 30 Hz to study 1 sec (or more) long discharges. The scattered light will be collected over an angular range of 60◦– 120◦from 28 spatial points in the midplane covering the entire plasma width and the outer midplane SOL. Each scattering signal will be spectrally resolved on five wavelength channels of a polychromator to obtain the electron temperature measurement. We will also present a method to monitor in situ laser alignment in the core during calibrations and plasma operations. I. INTRODUCTION The production of high density plasmas without triggering magnetohydrodynamic instabilities like Edge Localized Modes (ELMs) is an important requirement for realizing magnetic confinement fusion in a tokamak. Among the various tokamak configurations, spherical tokamaks (ST) offer compact-configuration plasmas. Moreover, negativetriangularity (NT)-shaped tokamak plasmas offer a wide range of advantages such as high-energy confinement, nonELMing plasmas, and detached-divertors along with highdensity operations1,2. Here triangularity (δ) refers to a parameter of the shape of the poloidal cross-section of the last closed flux surface of a tokamak3. To combine the benefits of spherical tokamaks and negative-triangularity, the SMall Aspect Ratio tokamak (SMART) is currently being commissioned at the University of Seville in Spain that aims to explore the physics of NT plasmas and compare it with PT counterpart scenarios4,5. We describe the design of the TS diagnostic for SMART to measure the spatially and temporally resolved electron temperature (Te) and density (ne)6. A TS diagnostic works by accelerating free plasma electrons using a linearly-polarized short-pulse laser beam. Accelerated electrons emit electromagnetic radiation. The scattered radiation is called TS radiation, which is collected and resolved spectrally on different wavelength bands to obtain Tefrom spectral broadening and nefrom the amplitude7. Knowledge of Teand neallows one to understand the effects of various plasma heating and confinement techniques on tokamak plasmas and the underlying physics in different regimes, for example, electron heat transport, particle transport, etc. The primary goal of the TS diagnostic on SMART is to facilitate physics studies by precisely resolving the core and the edge (pedestal) for both NT and PT configurations. This diagnostic provides detailed measurements across the HFS and LFS regions of the magnetic axis of SMART, as well as in the core plasma. The rest of the article is arranged as follows. In section II, we provide an overview of SMART and briefly describe the operational requirement of the TS diagnostic. The design of the TS diagnostic along with all its major components is given in section III, followed by a summary in section IV. II. OVERVIEW SMART is designed for physics studies by shaping plasma with δranging from −0.6 to +0.6, and the aspect ratio can be varied from 1.4 to 34. The operation of SMART is foreseen in three phases, see Table I. The toroidal magnetic field (Bt) will be varied from 0.1 T in Phase 1 to 1 T in Phase 3, and the plasma current (Ip) ranges from 100 kA in Phase 1 to 1 MA in Phase 3. The SMART plasmas will be heated in Phases 2 and 3 with neutral beam injection (NBI) to attain high temperatures. Parameters Phase 1 Phase 2 Phase 3 Ip[kA]100 200 −500 >500 Bt[T]0.1 0.4 1.0 τpulse [sec]0.15 0.5 >1 PECH [kW]6 6 200 PNBI [MW]- 0.3 - 1 1 TABLE I. Table of operating parameters in different SMART phases. Here PECH stands for launched electron cyclotron heating. Reproduced with permission from Podestà et al.8. CC BY 4.0. This is the author’s peer reviewed, accepted manuscript. However, the online version of record will be different from this version once it has been copyedited and typeset. PLEASE CITE THIS ARTICLE AS DOI: 10.1063/5.0219308 Thomson Scattering diagnostic for SMART 2 Based on the operational parameters given in Table I, a literature survey of STs is conducted to estimate the Terange of SMART plasmas in different phases of operation. The expected Terange strongly influences the design of the diagnostic for a typical density, ne∼1019 m−3. For example, the values of Tedetermine the wavelength ranges of the TS radiation that need to be measured. The survey to estimate Teand neis summarized in Table II. A comparison of Table Iand II shows that in Phase 1, SMART is expected to produce a minimum core Teof up to 100 eV and neup to 2.5×1019 m−3based on results from VEST/VEST-II9–11 under similar Ipand Btranges. GlobusM12 and START13 results suggest core Teand nein the range from 300 eV to 600 eV and up to 6 ×1019 m−3, respectively in Phase 2 in the presence of an external heating source and higher Ipand Bt. In Phase 3, SMART is anticipated to achieve Teup to 1 keV and neup to 10×1019 m−3based on data from Globus-M214–16 and ST4017. In the scrape-off layer (SOL), Teand nemay drop to a few eV and 0.5×1019 m−3or a lower value, respectively. Therefore, the SMART TS diagnostic is optimized for a wide range of expected SMART parameters under different operational phases to measure a wide Terange from 1 eV to 1 keV and nerange of 0.5−10 ×1019 m−3. Parameters VEST/ VEST-II START Globus-M Globus-M2 ST40 Ip[kA]50−150 200 120 −250 200 − 300 350 500− 580 Bt[T]0.15 0.3 0.4 0.7 0.9 <1.0 External Heating [MW] - 0.5 (NBI) 0.1 (RF power) 0.85 (NBI) 0.7 (two NBIs) 1.8 Te[keV]0.1 0.3 0.55 0.7− 0.9 1.5 0.9 ne[1019 m−3]2.5 6 6 8 −10 8 10 TABLE II. Table of achieved core Teand nein comparable STs at operating parameters similar to different SMART phases. Please note that the operation windows of comparable STs beyond the planned operation phases of SMART are not considered for comparison. III. THE SMART TS DIAGNOSTIC The TS diagnostic is designed to cover the first three operational phases of SMART, featuring multiple subsystems that enable the measurements of Teand neat various spatial locations and times during a plasma discharge. These subsystems are detailed in this section. A. High-repetition rate laser and beam transport An InnoLas-made Nd:YAG laser (model SL2500) operating with 2 Joule nominal energy per pulse at 30 Hz and pulse width of 10 ns at the fundamental wavelength of 1064 nm is purchased. The beam divergence and the pointing stability of this laser are 11.68 µrad and 0.5 mrad (full angle), respectively. This laser is capable of operating in a burst mode at reduced energy per pulse to achieve measurements at a highrepetition rate during a discharge. Here, a burst represents a FIG. 1. Here is a schematic of the laser beam transport and dump. group of pulses (4 to 6 in our case) fired at a fast rate. The frequency of pulses in a burst can be set at 1 kHz, 2 kHz or 4 kHz. For four pulses in a burst, the laser delivers 1.88 J energy per pulse at 4 kHz, 1.7 J at 2 kHz, and 1.57 J at 1 kHz burst. The energy per pulse drops further for 6 number of pulses in a burst. Moreover, the burst can be repeated at every ∼200 ms during a shot. This mode will be beneficial for exploring several fast phenomena and short-pulse discharges, for example, Phase 1 of SMART. The laser and ancillary instruments will be located in a room 10 m away from the SMART test cell. A schematic of the laser beam transport is shown in Fig. 1. The laser is equipped with a energy meter to make measurements at 30 Hz operations. However, the fast burst pulse energy measurements will be done at the laser head using a Coherent energy meter (model EnergyMax-USB J-50MT-10KHZ Energy Sensor) operating at 10 kHz repetition rate. The laser beam will be expanded from 12 mm diameter to 25 mm using a Galilean beam expander to reduce beam divergence and to keep the energy load on to the entry window below the damage threshold. After that, a set of mirrors and lenses will focus the vertically polarized laser beam into the midplane through a Brewster window to make Teand nemeasurements. Upon its exit from the main vessel, the laser beam energy will be measured, and the beam will be dumped on a Kentek-made beam dump housed outside the vacuum vessel. The laser is equipped with a visible alignment laser that will be used along with a camera for alignment of the laser prior to calibrations and operations. B. TS scattering-location selection and collection optics The optimal measurement locations and spacing between adjacent scattering points are determined by considering the expected variation in radial plasma pressure profiles at difThis is the author’s peer reviewed, accepted manuscript. However, the online version of record will be different from this version once it has been copyedited and typeset. PLEASE CITE THIS ARTICLE AS DOI: 10.1063/5.0219308 Thomson Scattering diagnostic for SMART 3 FIG. 2. This image shows the location of the TS measurement (the red empty rectangles) and alignment (the green rectangles) points along the major radius of SMART. These TS locations are determined from the qualitative variation of the plasma pressure along the SMART major radius at different PT and NT values. The plasma pressure profiles are obtained in ASTRA simulations using a GyroBohm model. ferent triangularity values as predicted in ASTRA simulation using a GyroBohm model4. The TS measurement locations and simulation data are shown in Fig. 2. Please note that the simulation profiles in the NT configuration are calculated by running ASTRA in predictive mode and using transport coefficients corresponding to ST plasmas with PT, as no machine has ever explored the combination of NT and low aspect ratio. Recently, more advanced simulations are performed using the TRANSP code and the Multi-Mode Model that provide similar core parameters8,18. Simulations suggest a narrow pedestal width, ∼1.2 cm, on LFS of the magnetic axis, and a slightly wider pedestal, ∼2 cm, on HFS due to the Shafranov shift. Additionally, the pedestal position on LFS shifts radially with a change in triangularity; however, this shift is not very prominent on HFS. The measurement points are therefore judiciously distributed to ensure dense coverage in both the LFS and the HFS regions, enabling detailed resolution of the edge pedestal in both PT and NT configurations. The details of the TS measurement points distribution in SMART is shown in Table III. More than a third of the measurement points are dedicated to LFS of the magnetic axis, six to the HFS pedestal, and a third are uniformly arranged in the core region. Radial coverage of 52 cm is achieved with 28 TS measurement points with a scattering angle (θsc) ranging from 60◦to 120◦, as shown in Fig. 3. The wide radial coverage is made possible using a custom reentrant quartz viewport that is designed to bring the collection optics closer to the laser line, and hence the measurement points. The distance of the measurement points from the collection optics varies from 50 cm to 70 cm. The clear diameter of quartz in the reentrant viewport is larger than 18 cm, enabling the use of lens elements Location LFS HFS Core Scattering length [mm] 5.8 9.2≤9.2 Separation between measurement points [mm] 7 10 35.4 No. of measurement points 12 6 10 TABLE III. This table shows the distribution of TS measurement points along the major radius of SMART. Here the scattering length refers to the light collection length along the laser beam that determines the scattered signal strength. Twelve measurement points on LFS are dedicated to providing a spatial resolution of 7 mm, and six on the HFS pedestal achieve 10 mm spatial resolution. Ten measurement points are uniformly arranged in the core region to provide a spatial resolution of 35.4 mm. with large aperture. There are six elements in the collection optics with their diameter varying from 9.2 cm (for the first and smallest element) to 15.7 cm (for the last and largest element). These design considerations ultimately enable us to employ fast collection optics and collect a strong light signal. Furthermore, the collection optics is designed to offer a low optical magnification, M, of 2.5×for the entire LFS measurement range, as shown in Fig. 4. Low M ensures that the projection of the optical fiber onto the laser line does not exceed the desired scattering length of 6 mm on LFS and hence provides us with 7 mm spatial resolution (i.e., the center-to-center separation between adjacent measurement points). The optical M increases to 4×for the HFS pedestal and some of the core scattering locations. This makes the scattering length to vary along the laser beam from 5.8 mm at the outboard edge to 9.2 mm at the inboard edge. The collection optics assembly will be housed in a dark enclosure stationed outside the vacuum vessel, and light will be collected from the midplane. An achromatic prism is used in front of lens elements in the collection optics to deviate its optical axis by 10◦. This prevents the optical path from clashing with the nearby poloidal coils. Decentered and tilted optical elements are used to correct asymmetric aberrations arising FIG. 3. This image shows the lines of sight of the Thomson scattering diagnostic in the mid-plane (the top view). There are 30 scattering locations, 28 of which are for measuring localized plasma parameters, and two are dedicated to monitoring the laser alignment with respect to the collection optics. This is the author’s peer reviewed, accepted manuscript. However, the online version of record will be different from this version once it has been copyedited and typeset. PLEASE CITE THIS ARTICLE AS DOI: 10.1063/5.0219308 Thomson Scattering diagnostic for SMART 4 FIG. 4. This image shows M (in the red circles), the optical magnification, of the collection optics along the major radius of SMART. The blue dotted line corresponds to M =2.5. from the achromatic prism. Using decentred and tilted elements also avoids using a shallow cylindrical optical surface on the prism, which is difficult to manufacture. The resultant optical system uses all conventional spherical lens elements, which are both easier to manufacture and assemble, while achieving the same optical performance as a more complicated system with toroidal surfaces. At the end of the collection optics, a wire grid polarizer will be installed to reduce randomly polarized plasma background light and collect only the polarized TS light. The collection optics images the laser beams onto a continuous fiber bundle holder for mounting 30 rectangular Optical Fiber Bundles (OFB). All OFBs are made up of low-OH pure silica core/polymer cladding 210/230-micrometer diameters with their jackets removed and a numerical aperture (NA) of 0.285. The rectangular side of each OFB has an area of 2.3×1.44 mm2and contains 66 fibers. The other end of the OFB that goes to the polychromator comprises fibers of two OFBs in a circular cross section of 3 mm diameter in a random distribution. The two legs of the composite OFB have different lengths, permitting time multiplexing of the data. More details are provided in the next subsection. C. Measurement of TS spectrum from collected light Parameters Ch 1 Ch 2 Ch 3 Ch 4 Ch 5 CWL (nm) 1061.1 1057.7 1047.5 1017.5 917 Bandwidth (nm) 2 5.5 15 45 155 Quantum efficiency (%) 36.2 38.9 44.5 62.5 87.6 TABLE IV. This table lists CWL and bandwidth (full-width at halfmaxima) of five interference filters mounted onto the polychromators and the quantum efficiencies of the APDs at CWL. Measuring the TS spectrum involves recording the intensity of scattered light at different wavelengths. The wavelength range that needs to be measured depends on the Terange to be measured. To resolve the expected Terange of SMART, discussed in section II, we purchased 14 polychromators from UKAEA19. Each polychromator is designed to accommodate up to seven spectral channels (Ch), but is currently equipped with five optical interference filters. The central wavelength (CWL) and bandwidth of these interference filters and the quantum efficiency of the avalanche photodiodes (APD that converts the optical signal into voltages) at CWL are listed in Table IV, and the TS spectrum for the expected Terange is FIG. 5. The TS spectrum is plotted for different values of Teand θsc. Low Te(1 - 10 eV) is expected in the SOL region, where θsc is 60◦ in LFS or 120◦in HFS. Moderate (100 eV) to high Te(0.5 - 1 keV) is expected near the outer plasma edge and in the core region, where θsc is 115◦in HFS (or 65◦in LFS) and 90◦, respectively. The alternate pink and yellow colors in the background represent the passing wavelength bands of five interference filters, as detailed in Table IV. The narrow bandwidth filter, i.e., Ch 1 of Table IV, enables low Te measurements. shown in Fig. 5. The TS spectrum is calculated for the combinations of Teand θsc that are expected at different radial locations, as guided by Fig. 2. Each polychromator is equipped with a narrow bandwidth filter, i.e., Channel 1 of Table IV, to enables low Temeasurements. The additional two channels on each polychromator can be populated in the future to cover an extended Te range. Based on the future SMART data and physics of interest, the core polychromator channels can be populated with lower wavelength filters to measure Tehigher than 1 keV and edge channels with higher wavelength filters to improve the low Teand nerange measurements. To optimize the use of polychromators, each polychromator will collect a scattered light signal from two scattering locations in the mid-plane using an unequal length bifurcated OFB. The length of two bifurcated bundle legs is 12 m and 22 m. The length difference is kept as 10 m to introduce a time separation of 48 ns between the signals from two scattering locations. This scheme enables 14 polychromators to provide information on plasma parameters from 28 different radial locations, and hence offers better spatial resolution and coverage than that provided by 14 radial locations. Rotational Raman calibration will be used to determine the sensitivity of the light signal from different scattering locations in the midplane that will be used in density determination20. Because of the sensitive nature of the calibration on the laser alignment and the possibility of quartz window degradation overtime due to coating, the calibration will be performed both during the installation of the TS system and at the start of every major SMART campaign. D. Laser alignment monitoring We developed a novel set up to actively monitor in situ laser alignment during each shot such that corrective actions can be taken in between shots if any misalignment occurs. In this setup, two scattering locations in the core, indicated in the green color in Fig. 2, are dedicated to monitoring This is the author’s peer reviewed, accepted manuscript. However, the online version of record will be different from this version once it has been copyedited and typeset. PLEASE CITE THIS ARTICLE AS DOI: 10.1063/5.0219308 Thomson Scattering diagnostic for SMART 5 FIG. 6. This image shows a quad-OFB that is used with a onechannel polychromator for monitoring laser alignment with respect to the collection optics. The quad-OFB has four unequal-length OFB legs to introduce a time delay between the signals from different points. laser alignment using a quad-OFB and a one-channel polychromator. The quad-OFB has four unequal-length legs, as shown in Fig. 6, to introduce time delay between signals from four legs. Each scattering location is covered by two legs of the quad-OFB arranged vertically in a rectangle, of area 1.44 mm×2.3 mm, such that one bundle collects a light signal from the top half of the laser line, whereas the second collects light from the bottom half. The one-channel polychromator is purchased along with the other 14 polychromators. It is equipped with one interference filter with a passing wavelength band of 1040−1055 nm (i.e., Channel 3 of Table IV). The radial position of the alignment fibers and passing wavelength band of the interference filter are selected such that the two measurement points are farthest apart in the core and gather a strong signal during Raman calibrations and day-to-day operations while ensuring least contribution from Rayleigh light. Using the same polychromator on all the OFB legs ensures that the four positions (radial and vertical) record equal signal strength for a perfectly aligned laser beam with respect to the collection optics. IV. SUMMARY We described the design of a multipulse Thomson scattering system to measure the electron temperature and density profiles in the mid-plane of SMART. Special emphasis was laid on measuring the pedestal region on LFS and HFS of the magnetic axis with a high spatial resolution to compare PT and NT plasma scenarios. The diagnostic will operate with (i) a high spatial resolution of 7 mm (separation between 12 adjacent points) in the LFS pedestal region and 10 mm in the HFS region, and (ii) a wide dynamic range, 1 eV to 1 keV, to resolve large gradients formed at the plasma edge and in SOL under different triangularity conditions and low aspect ratios. A fast collection optics enables efficient use of the fourteen polychromators available to collect the plasma information at 28 spatial locations covering the entire plasma width along with the outer midplane SOL. In addition, the collection optics offer a low M in the LFS region, allowing tight spacing between measurement points and a high spatial resolution, as mentioned above. A novel setup is developed to monitor in situ laser alignment using a polychromator equipped with one interference filter and a quad-OFB at two scattering locations in the core during Raman calibrations and day-to-day operations. The design and order of most major parts of the SMART TS diagnostic (laser, polychromators, collection optics, fiber bundles, data acquisition, etc.) are complete. ACKNOWLEDGMENTS This work was primarily supported by the U.S. Dept. of Energy, Office of Fusion Energy Sciences under contract number DE-AC02-09CH11466. A part of the work is carried out within the EUROfusion Consortium framework, partially funded by the EU via the Euratom Research and Training Program (Grant Agreement No 101052200 — EUROfusion). The Swiss contribution to this work has been funded by the Swiss State Secretariat for Education, Research and Innovation. DATA AVAILABILITY STATEMENT The data that support the findings of this study are available from the corresponding author upon reasonable request. 1Y. Camenen, A. Pochelon, R. Behn, A. Bottino, A. Bortolon, S. Coda, A. Karpushov, O. Sauter, G. Zhuang, and the TCV team, Nucl. Fusion 47, 510 (2007). 2M. Austin, A. Marinoni, M. Walker, M. Brookman, J. Degrassie, A. Hyatt, G. McKee, C. Petty, T. Rhodes, and S. Smith et al., Phys. Rev. Lett. 122, 115001 (2019). 3T. C. Luce, Plasma Phys. and Controlled Fusion 55, 095009 (2013). 4A. Mancini, L. Velarde, E. Viezzer, D. J. Cruz-Zabala, J. F. RiveroRodriguez, M. Garcia-Muñoz, L. Sanchis, A. Snicker, J. SegadoFernández, and J. Garcia-Dominguez et al., Fusion Eng. Des. 192, 113833 (2023). 5J. Segado-Fernandez, A. Mancini, J. Garcia-Dominguez, J. Ayllon-Guerola, D. Cruz-Zabala, L. Velarde, M. Garcia-Muñoz, E. Viezzer, C. Navarro, M. Agredano-Torres, and P. Vicente-Torres et al., Fusion Eng. Des. 193, 113832 (2023). 6M. Kaur, A. Diallo, B. LeBlanc, M. Podesta, J. Berkery, J. SegadoFernandez, E. Viezzer, M. Garcia-Munoz, A. Mancini, and D. CruzZabala, in 65th Annual Meeting of the American Physical Society Division of Plasma Physics (Denver, Colorado) (2023) pp. AP01–031. 7S. Prunty, Physica Scripta 89, 128001 (2014). 8M. Podestà, D. Cruz-Zabala, F. Poli, J. Dominguez-Palacios, J. Berkery, M. Garcia-Muñoz, E. Viezzer, A. Mancini, J. Segado, and L. Velarde et al., Plasma Phys. and Controlled Fusion 66, 045021 (2024). 9D. Kim, Y.-G. Kim, J.-H. Lee, Y.-S. Na, and Y. Hwang, Fusion Eng. Des. 146, 1131 (2019). 10J.-H. Kim, Y.-G. Kim, D. Kim, J.-h. Lee, and Y. Hwang, Rev. Sci. Instrum 92, 043549 (2021). 11E. Jung, Y. Na, S. Kim, W. Jeong, J.-K. Park, T. Hahm, Y.-c. Ghim, and Y. Hwang, Nucl. Fusion 62, 126029 (2022). 12V. Gusev, N. Bakharev, V. Belyakov, B. Y. Ber, E. Bondarchuk, V. Bulanin, A. Bykov, F. Chernyshev, E. Demina, and V. Dyachenko et al., Nucl. Fusion 55, 104016 (2015). 13A. Sykes, R. Akers, L. Appel, P. G. Carolan, N. J. Conway, M. Cox, A. R. Field, D. A. Gates, S. Gee, and M. Gryaznevich et al., Plasma Phys. Control. Fusion 39, B247 (1997). 14A. Telnova, G. Kurskiev, I. M. Balachenkov, N. N. Bakharev, V. K. Gusev, N. S. Zhil’tsov, A. A. Kavin, E. O. Kiselev, V. B. Minaev, I. Miroshnikov, et al.,Technical Physics 66, 401 (2021). 15N. Bakharev, I. Balachenkov, F. Chernyshev, I. Chugunov, V. Dyachenko, V. Gusev, M. Iliasova, E. Khilkevitch, N. Khromov, and E. Kiselev et al., Plasma Phys. Reports 46, 675 (2020). 16G. Kurskiev, I. Miroshnikov, N. Sakharov, V. Gusev, Y. V. Petrov, V. Minaev, I. Balachenkov, N. Bakharev, F. Chernyshev, and V. Y. Goryainov et al., Nucl. Fusion 62, 104002 (2022). 17M. Gryaznevich, T. L. P. Team, and T. L. H. T. for Tokamak Energy Ltd, Nucl. Fusion 62, 042008 (2022). 18D. J. Cruz-Zabala, M. Podesta, F. Poli, S. Kaye, M. Garcia-Munoz, E. Viezzer, and J. Berkery, Nucl. Fusion (under preparation). 19R. Scannell, M. Walsh, P. Carolan, A. Darke, M. Dunstan, R. Huxford, G. McArdle, D. Morgan, G. Naylor, and T. O’Gorman et al., Rev. Sci. Instrum 79, 10E730 (2008). 20J. Howard, B. W. James, and W. I. B. Smith, Journal of Physics D: Applied Physics 12, 1435 (1979). This is the author’s peer reviewed, accepted manuscript. However, the online version of record will be different from this version once it has been copyedited and typeset. PLEASE CITE THIS ARTICLE AS DOI: 10.1063/5.0219308