scieee AI-readable full text Open interactive document viewer

The naturally occurring radioactivity of ‘scalar energy’ pendants and concomitant radiation risk

Hassan, Halmat Jalal; Hashim, Suhairul; Sanusi, Mohamad Syazwan Mohd; Jamal, Mohamad Hidayat; Bradley, David Andrew; García-Tenorio García-Balmaseda, Rafael

Abstract

Forming part of a study of radiological risk arising from use of radioactive consumer products, investigation is made of pendants containing naturally occurring radioactive material. Based on use of gamma-ray spectrometry and Monte Carlo (MC) simulations, the study investigates commercially available ‘scalar energy pendants’. The doses from these have been simulated using MIRD5 mathematical phantoms, evaluation being made of dose conversion factors (DCFs) and organ dose. Metallic pendants code MP15 were found to contain the greatest activity, at 7043 ± 471 Bq from 232Th, while glass pendants code GP11 were presented the greatest 238U and 40K activity, at 1001 ± 172 and 687 ± 130 Bq respectively. MP15 pendants offered the greatest percentage concentrations of Th, Ce, U and Zr, with means of 25.6 ± 0.06, 5.6 ± 0.005, 1.03 ± 0.04 and 28.5 ± 0.08 respectively, giving rise to an effective dose of 2.8 mSv for a nominal wearing period of 2000 h. Accordingly, these products can give rise to annual doses in excess of the public limit of 1 mSv.

Full text

RESEARCH ARTICLE The naturally occurring radioactivity of ‘scalar energy’ pendants and concomitant radiation risk Halmat Jalal HassanID 1,2 *, Suhairul Hashim 1,3 , Mohamad Syazwan Mohd Sanusi 1 , Mohamad Hidayat Jamal 4☯ , Sitti Asmah Hassan 4☯ , David Andrew Bradley 5,6‡ , Rafael Garcı ´a-Tenorio 7,8‡ , Rozman Mohd Tahar 9☯ 1Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, UTM, Skudai, Johor, Malaysia, 2Department of Physics, College of Education, University of Sulaimani, Sulaimani, Kurdistan, Iraq, 3Ibnu Sina Institute for Scientific and Industrial Research (ISISIR), Universiti Teknologi Malaysia, UTM, Skudai, Johor, Malaysia, 4Faculty of Engineering, Universiti Teknologi Malaysia, UTM, Skudai, Johor, Malaysia, 5Centre for Applied Physics and Radiation Technologies, Sunway University, Bandar Sunway, Selangor, Malaysia, 6Department of Physics, University of Surrey, Guilford, United Kingdom, 7Department of Applied Physics II, ETSA, University of Seville, Seville, Spain, 8Centro Nacional de Aceleradores, CNA, University of Seville-J. Andalucı ´a-CSIC, Seville, Spain, 9Atomic Energy Licensing Board, Dengkil, Selangor, Malaysia ☯These authors contributed equally to this work. ‡ These authors also contributed equally to this work. *[email protected] Abstract Forming part of a study of radiological risk arising from use of radioactive consumer products, investigation is made of pendants containing naturally occurring radioactive material. Based on use of gamma-ray spectrometry and Monte Carlo (MC) simulations, the study investigates commercially available ‘scalar energy pendants’. The doses from these have been simulated using MIRD5 mathematical phantoms, evaluation being made of dose conversion factors (DCFs) and organ dose. Metallic pendants code MP15 were found to contain the greatest activity, at 7043 ±471 Bq from 232 Th, while glass pendants code GP11 were presented the greatest 238 U and 40 K activity, at 1001 ±172 and 687 ±130 Bq respectively. MP15 pendants offered the greatest percentage concentrations of Th, Ce, U and Zr, with means of 25.6 ±0.06, 5.6 ±0.005, 1.03 ±0.04 and 28.5 ±0.08 respectively, giving rise to an effective dose of 2.8 mSv for a nominal wearing period of 2000 h. Accordingly, these products can give rise to annual doses in excess of the public limit of 1 mSv. Introduction As with other life forms, humans are continually exposed to ionizing radiation from natural radionuclides, including from terrestrial media, building materials, water, air and food. The International Atomic Energy Agency (IAEA) defines naturally occurring radioactive material (NORM) as “Radioactive material containing no significant amounts of radionuclides other than naturally occurring radionuclides”; included in this are materials in which the activity concentrations of the naturally occurring radionuclides have been changed by a process [1]. PLOS ONE PLOS ONE | https://doi.org/10.1371/journal.pone.0250528 June 1, 2021 1 / 12 a1111111111 a1111111111 a1111111111 a1111111111 a1111111111 OPEN ACCESS Citation: Hassan HJ, Hashim S, Mohd Sanusi MS, Jamal MH, Hassan SA, Bradley DA, et al. (2021) The naturally occurring radioactivity of ‘scalar energy’ pendants and concomitant radiation risk. PLoS ONE 16(6): e0250528. https://doi.org/ 10.1371/journal.pone.0250528 Editor: Domokos Ma ´the ´, Semmelweis University, HUNGARY Received: December 27, 2020 Accepted: April 7, 2021 Published: June 1, 2021 Copyright: ©2021 Hassan et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Data Availability Statement: All relevant data are within the manuscript and its Supporting Information files. Funding: This work was supported by the Ministry of Science, Technology and Innovation (MOSTI) of Malaysia using Kumpulan Wang Amanah (KWA) Majlis Sains dan Penyelidikan Kebangsaan (MSPK). The authors gratefully acknowledge the Ministry of Higher Education Malaysia and Universiti Teknologi Malaysia through UTM High Impact Research Grant (No. 09G08). We Scalar energy products, a recent health fad introduced into local and online markets in Malaysia, the country in which present study has been carried out, are positioned as pendants that when worn offer an alternative form of medicine. At the outset, let it be noted that the term scalar energy finds no conventional scientific definition, considered to be meaningless jargon by the present authors. The manufacturers of the pendants state them to be composed of volcanic materials and/or other minerals, the purveyors and manufacturers linking the supposed health benefits with negative ion technology and quantum science, also using further jargon such as energy quantum pendants and volcanic lava energy. The claimed health benefits include improved circulation, stamina and flexibility, with an ability to detoxify and enhance energy levels, also being linked with prevention of cancer [2]. Additional claims include that they are a way to maintain health, balance energy and improve emotional well-being, also protecting against electromagnetic fields [3]. As previously shown, such products contain thorium and uranium, concentrated in activity [4]. Given that over time risks have been identified, NORM has become increasingly subject to monitoring and regulation [5]; the IAEA safety guide “Radiation Safety for Consumer Products” [6] recommending the use of such items to first be justified. The pendants are apparently devoid of any scientific evidence of benefit to the general public [6,7]. In order to limit radiation exposure from NORM-added consumer products, the Malaysian Atomic Energy Licensing Board (AELB) instituted control via its technical document LEM/TEK/69 [8]. This was preceded by the United States Environmental Protection Agency (EPA) guidelines for regulation of NORM [9]. Despite such concerns, globally harmonized regulations have yet to be established, regulating and controlling radioactive content consumer products [10]. The purpose of present study has been to investigate the pendants, the activity of the longlived radionuclides 238 U, 232 Th and 40 K being measured and potential dose to wearers being evaluated via Monte Carlo (MC) simulation. In this regard, exposure was simulated via the use of MIRD5 mathematical male and female phantoms, with evaluation made of dose conversion factors (DCFs) and organ dose, focusing on assessing external exposure to wearers. Materials and methods Sampling and HPGe γ-spectrometry The pendants are said to contain volcanic lava, zirconium, anions and monazite, monazite and zirconium being known to contain uranium and thorium [5]. For current study a total of 20 pendants were purchased online, upon delivery there being no evidence of information on the radioactivity contained within. The products were ten ceramic-based pendants (assigned codes CP1 to CP10), four glass-based pendants (codes GP11 to GP14), five metallic-based pendants (code MP15 to MP19), and one pendant with an outer plastic cover, code PP20 (Fig 1). Using a well-shielded high purity Ge (HPGe) spectrometer, each pendant was counted for a period of 20 h, each firmly located within the shielding in a holder coaxially aligned with and 3 cm above the top cap of the HPGe detector, a geometrical configuration maintained for all pendants. The gamma emissions were directly measured using an ORTEC GEM Series P-type coaxial HPGe spectrometer (GEM20-76-LB-C-SMPCFG-SV-LB-76; 33% relative efficiency; 1.8 keV FWHM at 1332 keV), providing high-performance gamma spectroscopy within the photon energy range 40 keV to several MeV. The system, equipped with a Mobius cooling system, also uses high-resolution gamma spectroscopy software (VISION version 8) for spectral analysis. The spectra, collected over 16380 channels, were calibrated using a 152 Eu standard point source, providing a wide range of photon energies (121.78, 244.6, 344.3, 411.1, 778.9, 867, 964, 1112 and 1528 keV) see (Fig 2). PLOS ONE Naturally occurring radioactivity in ’scalar energy’ pendant products PLOS ONE | https://doi.org/10.1371/journal.pone.0250528 June 1, 2021 2 / 12 acknowledge the cooperation with the project partners i.e., International Atomic Energy Agency and Atomic Energy Licensing Board, Malaysia for expert mission and procurement support through IAEA TC programme (MAL9018: Strengthening the Regulatory Infrastructure for Radiation and Nuclear Safety). Competing interests: The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. The counting efficiencies of the 238 U series for these measurement conditions was 1.1% for 214 Pb (351.8 keV) and 0.64% for 214 Bi (609.3 keV), while for the 232 Th series, they were 1.52% for 212 Pb (238.4 keV), 1.24% for 228 Ac (338.2 keV), 0.6% for 212 Bi (727 keV), 0.71% for (583 keV), 0.16% for 208 Tl (2614 keV), and 0.2% for 40 K (1460 keV). With the exception of 40 K, all gamma lines have a high branching ratio [11]. The efficiency curve (Fig 3) covers the photon energy range 121.78–1528 keV with a fitting polynomial of order 4, as given by Alnour et al. Fig 1. Scalar energy pendant samples. https://doi.org/10.1371/journal.pone.0250528.g001 Fig 2. Calibration energy spectrum (standard point source 152 Eu). https://doi.org/10.1371/journal.pone.0250528.g002 PLOS ONE Naturally occurring radioactivity in ’scalar energy’ pendant products PLOS ONE | https://doi.org/10.1371/journal.pone.0250528 June 1, 2021 3 / 12 [12] and Gouda et al. [13], shown in (1) below: log ðεÞ ¼ P4 i¼0ci:log ðEÞið1Þ with (ε) the full energy peak efficiency at energy E and c i the fitting coefficients determined via calculations. Interpolation was used to calculate the absolute efficiency of unknown radionuclides in the samples. Elemental characterization of pendants For elemental analysis, the pendants were analysed using a Cartesian Geometry Energy Dispersive X-Ray Fluorescence (ED-XRF) spectrometer (model; NEX CG–CG1240), XRF offering non-destructive investigation in determining elemental content, including of consumer and food products [14–16]. The samples were prepared in homogenized powder form. XRF analysis of four such pendants has previously been carried out by Pabroa et al. [2]. Monte Carlo (MC) simulation and evaluation of Annual Effective Dose (AED) To estimate the equivalent organ doses and annual effective dose (AED) arising from use of the pendants simulation was undertaken using the Monte Carlo N-Particle radiation transport code version MCNP5 (Los Alamos National Laboratory), also involving use of Medical Internal Radiation Dose (MIRD) mathematical phantoms, male and female, with the female version shown in Fig 4 [5,17,18]. The male phantom is 178 cm tall, weight 91 kg, while the female phantom is of height 168 cm and weight 72 kg. The pendant was taken to be a sphere of 2 cm diameter, dose evaluations being carried out with the pendant located on the chest. Where, color of the phantom represents different composition and density of tissues and bone; green, yellow and aqua represent lung tissue, soft tissue, and bone, respectively. Fig 3. Energy efficiency of HPGe detector (standard point source 152 Eu). https://doi.org/10.1371/journal.pone.0250528.g003 PLOS ONE Naturally occurring radioactivity in ’scalar energy’ pendant products PLOS ONE | https://doi.org/10.1371/journal.pone.0250528 June 1, 2021 4 / 12 Dose calculation Estimation of equivalent organ dose and effective dose, using (DCFs). The radiological protection quantity equivalent dose denoted H T , defined by: HT¼SwRDT;Rð2Þ with H T (Sv) the equivalent dose of organ or tissue T, w R denoting the radiation weighting factor, for gamma radiation is unity (1), and D T,R (Gy) the mean absorbed dose in an organ or tissue T, due to gamma radiation [19], and therefore the effective dose, E (Sv), defined by a sum of weighted tissue equivalent dose as: E¼SwTHTð3Þ Where w T is the tissue weighting factor for tissue T, and summation w T is unity (1) [19–21]. The new Dose Conversion Factors (DCFs), calculated from the Monte Carlo simulation for a wearer of pendant. Where the (DCFs) formed the coefficient,F T , the equivalent dose in organ or tissue per unit integrated exposure. From this coefficient F T , the equivalent dose H T for any organ or tissue can be calculated as: HT¼A�t�FTð4Þ Where A(Bq/pendant) represents the radioactivity from the pendant, trepresents the exposure time (hours), (8 hr/day �5 days/week �50 weeks/year) [5], and coefficient F T (Sv h -1 per Bq/pendant) represents the equivalent dose in organ or tissue per unit integrated exposure [3]. Fig 4. MIRD human phantoms for a scalar pendant, as used in MC simulation. https://doi.org/10.1371/journal.pone.0250528.g004 PLOS ONE Naturally occurring radioactivity in ’scalar energy’ pendant products PLOS ONE | https://doi.org/10.1371/journal.pone.0250528 June 1, 2021 5 / 12 Estimation dose rate using HPC software. The dose-rate in air, bone, and muscle, calculated for the wearer, was obtained using Syberad’s Health Physicist’s Companion program. The program executable file is HPC.exe. Syberad’s reference number is HP-CD1. This database is a user-friendly software program designed for radiation protection professionals, useful in obtaining information in respect of more than 2800 nuclides [22]. In particular, it can be used to calculate the dose-rate for any radionuclide, for a given specific activity, at any distance, with various shielding provision [3]. Dose-rates were calculated for the radionuclides 238 U, 232 Th and 40 K in the pendant, at close-up distance from the user. Measuring dose equivalent using a survey meter. The dose equivalent from the pendants was also measured, use being made of a calibrated identiFinder 2, FLIR Survey Meter, recording exposure dose-rates (in μSv/h), also identifying the radionuclides contained in the pendants. Results and discussion Measurements of the 238 U, 232 Th and 40 K activity in the pendants Using the ORTEC GEM Series P-type coaxial HPGe detector, gamma spectrometry measurements were made for each of the 20 pendants, with an example shown in Fig 5 for pendant MP15, identifying 40 K activity as well as U and Th series nuclides, including 214 Pb, 214 Bi, 212 Pb, 228 Ac, 208 Tl (Table 1). The results for 238 U were estimated from the average of results for gamma emissions from 214 Pb (295 keV and 351.8 keV) and 214 Bi (609 keV and 1764 keV). The results for 232 Th were estimated from the average of the gamma emissions of 212 Pb (238 keV), 228 Ac (338 keV and 911 keV), 212 Bi (727 keV), and 208 Tl (583 keV and 2614 keV), secular equilibrium being assumed [23]. Pendant MP15 showed the greatest activity, at 7043 ±471 Bq from 232 Th, while glass pendant GP11 presented the greatest activity for 238 U and 40 K, at 1001 ±172 and 687 ±130 Bq respectively. Across the same category of pendant considerable difference in radioactivity Fig 5. Example spectra obtained from an MP15 metallic scalar pendant sample. https://doi.org/10.1371/journal.pone.0250528.g005 PLOS ONE Naturally occurring radioactivity in ’scalar energy’ pendant products PLOS ONE | https://doi.org/10.1371/journal.pone.0250528 June 1, 2021 6 / 12 content can be observed. For elemental content, four pendants were analysed via use of an XRF spectrometer (Table 2). Table 2 shows pendants CP6 and GP11 to be made primarily of Si and Al, while Al is the primary constituent of CP8 and for MP15 the primary component is Zr. NORM and rare earth elements (REEs) are found in all four analysed samples, MP15 recording the greatest concentration percentage of Th, Ce, U and Zr, at 25.6 ±0.06, 5.6 ±0.005, 1.03 ±0.04 and 28.5 ±0.08, respectively. The concentration (and activity) of U and Th for pendant MP15 were 10,090 ppm (872 Bq) and 260,000 ppm (7389 Bq) respectively. The results for samples MP15, as shown in (Tables 1and 2) are comparable. Organ equivalent dose For pendants CP8, GP11 and MP15, Fig 6 shows results for 21 organs, the organ equivalent dose being calculated using the MIRD5 mathematical male and female phantoms. The thymus, thyroid, oesophagus, lung and heart are among the organs most greatly exposed, a result of their close distance to the source. For CP8, the highest organ equivalent dose was shown to be the heart, at 2.81 and 2.31 mSv y -1 for the male and female phantom respectively, assuming a nominal wearing period of 2000 hours in one year. The equivalent dose to the breast is also greater than that of other organs due to the area of exposure and close distance from the pendant, the pendant being simulated to be on the chest. In the case of GP11, the greatest organ equivalent dose was for the female breast, at 5.32 mSv y -1 . For MP15 the muscle equivalent Table 1. Activity (in Bq/pendant) of U-238, Th-232 and K-40 in the pendants. Sample U-238 Th-232 K-40 Ceramic Pendants CP1 13.4 ±2.3 148 ±10 155 ±27 CP2 459 ±77 885 ±59 308 ±56 CP3 75 ±12 652 ±66 278 ±50 CP4 138 ±23 992 ±104 313 ±56 CP5 185 ±32 1515 ±169 293 ±53 CP6 106 ±18 748 ±147 104 ±19 CP7 172 ±29 1158 ±122 295 ±53 CP8 373 ±63 2785 ±180 260 ±50 CP9 53 ±9 356 ±23 97 ±18 CP10 55 ±10 265 ±18 116 ±21 Glass Pendants GP11 1001 ±172 6969 ±483 687 ±130 GP12 447 ±76 2805 ±185 262 ±48 GP13 288 ±48 1906 ±124 164 ±30 GP14 440 ±75 2499 ±166 262 ±51 Metallic Pendants MP15 927 ±157 7043 ±471 536 ±100 MP16 702 ±120 5348 ±363 514 ±95 MP17 9 ±1.5 73 ±5 73 ±11 MP18 6 ±1 41 ±3 20 ±3.5 MP19 22 ±3 167 ±11 20 ±4 Oute Plastic Pendant PP20 14 ±3 3552 ±239 395 ±72 https://doi.org/10.1371/journal.pone.0250528.t001 PLOS ONE Naturally occurring radioactivity in ’scalar energy’ pendant products PLOS ONE | https://doi.org/10.1371/journal.pone.0250528 June 1, 2021 7 / 12 dose is also relatively high, at 2.65 and 2.45 mSv y -1 for the male and female respectively, due to the area exposed. Comparison of MC simulations were made with the only other known work, that of Lee et al. [5], using the ICRP reference phantom and MCNPX. Table 3 shows equivalent doses (in mS/y), using Syberad’s Health Physicist’s Companion program, MP15 recording the highest annual doses, at 3.99, 4.08 and 4.24 mSv/y in air, bone and muscle, respectively. The HPC program calculated dose based on the wearer being exposed for a nominal period of 2000 hours per year. For CP8, the equivalent dose in muscle is 1.47 and 1.27 mSv/y for males and females respectively, comparable with the HPC result of 1.85 mSv/y (Table 3), in support of results obtained using the HPC program. Table 2. Elemental composition of pendants. Element Samples (% Concentration) CP6 CP8 GP11 MP15 Na 1.95 ±0.2 ND�6.10 ±0.01 ND Al 13.9 ±0.02 76.5 ±0.07 5.95 ±0.02 8.15 ±0.01 Si 63.0 ±0.06 7.78 ±0.01 62.3 ±0.07 9.99 ±0.01 K 0.75 ±0.02 1.10 ±0.03 2.30 ±0.02 2.10 ±0.02 Ti 0.36 ±0.01 3.20 ±0.01 0.70 ±0.001 0.90 ±0.01 Cr 0.55 ±0.003 0.82 ±0.03 0.30 ±0.002 0.20 ±0.02 Fe 8.32 ±0.003 2.90 ±0.03 1.20 ±0.003 2.49 ±0.03 Co 0.03 ±0.002 0.03 ±0.001 0.02 ±0.001 ND Sr 0.04 ±0.001 0.03 ±0.001 0.02 ±0.001 ND Zr 0.60 ±0.003 0.56 ±0.003 1.80 ±0.06 28.5 ±0.08 U 0.05 ±0.001 0.05 ±0.001 0.45 ±0.001 1.03 ±0.04 Ra 0.02 ±0.001 0.02 ±0.001 0.01 ±0.001 0.04 ±0.001 Pb 0.03 ±0.001 0.02 ±0.001 0.10 ±0.001 0.03 ±0.001 La 0.06 ±0.001 0.03 ±0.001 0.10 ±0.001 2.53 ±0.003 Ce 0.12 ±0.006 0.13 ±0.01 0.70 ±0.009 5.60 ±0.005 Th 0.89 ±0.002 1.10 ±0.06 12.6 ±0.005 25.6 ±0.06 Eu 0.24 ±0.005 ND ND 1.0 ±0.005 Ba 0.02 ±0.001 0.03 ±0.001 0.10 ±0.01 0.20 ±0.001 Gd 0.07 ±0.003 0.07 ±0.001 0.70 ±0.01 0.40 ±0.002 ND�: Not Detected https://doi.org/10.1371/journal.pone.0250528.t002 Fig 6. Organ equivalent dose (mSv/y) for 21 organs using the MIRD5 mathematical male and female phantoms, for: (a) CP8; (b) GP11; (c) MP15. https://doi.org/10.1371/journal.pone.0250528.g006 PLOS ONE Naturally occurring radioactivity in ’scalar energy’ pendant products PLOS ONE | https://doi.org/10.1371/journal.pone.0250528 June 1, 2021 8 / 12 Evaluation of annual effective dose The annual effective dose for the 20 pendants are presented in Fig 7, MP18 recording the lowest annual effective dose, at 10.6 μSv y -1 , while pendant MP15 indicated the highest annual effective dose, at 2.81 mSv y -1 . As in Fig 7, close contact with the pendants can infer annual effective doses in excess of the annual dose limit of 1 mSv/y for members of the public [6,7]. The alpha emissions are essentially absorbed within the pendant, posing no threat to health, while beta emissions from the pendants will be mostly absorbed within the epidermal layers of the skin. Conversely, gamma radiation is deeply penetrating, involving large areas of tissue and organs. The dose equivalent was also measured for the eight pendants capable of giving rise to annual effective doses in excess of 1 mSv/y. For this, use was made of a calibrated IdentiFinder 2, FLIR Survey Meter, recording dose rates in μSv/h and identifying the radionuclides contained within the pendants (Table 4). The highest dose equivalent, at 0.74 ±0.1 μSv/h, was from MP15. Regarding the wearing period, we suggest 8 hours per day, 2000 hours per year, to be likely for those who purchase such items. For this, the annual dose reaches a value of 1.5 mSv y -1 Table 3. Annual dose (in mSv/y) due to U-238, Th-232 and K-40, obtained using the HPC program. Sample Air Bone Muscle Ceramic Pendant CP6 0.88 0.93 0.98 CP8 1.64 1.71 1.85 Glass Pendant GP11 3.59 3.74 4.02 Metallic Pendant MP15 3.99 4.08 4.24 https://doi.org/10.1371/journal.pone.0250528.t003 Fig 7. Annual effective dose for the 20 scalar pendants demonstrating measurable gamma activity. https://doi.org/10.1371/journal.pone.0250528.g007 PLOS ONE Naturally occurring radioactivity in ’scalar energy’ pendant products PLOS ONE | https://doi.org/10.1371/journal.pone.0250528 June 1, 2021 9 / 12