scieee AI-readable full text Open interactive document viewer

Neutron capture cross section measurement of U 238 at the CERN n-TOF facility in the energy region from 1 eV to 700 keV

Mingrone, F.; Massimi, C.; Vannini, Gianni; Colonna, Nicola; Gunsing, Frank; Žugec, P.; Altstadt, Sebastian G.; Andrzejewski, J.; Audouin, Laurent; Cortés Giraldo, Miguel Antonio

Abstract

The aim of this work is to provide a precise and accurate measurement of the 238U(n,γ ) reaction cross section in the energy region from 1 eV to 700 keV. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behavior of the reactor core. In particular, fast reactors, which are experiencing a growing interest for their ability to burn radioactive waste, operate in the high energy region of the neutron spectrum. In this energy region most recent evaluations disagree due to inconsistencies in the existing measurements of up to 15%. In addition, the assessment of nuclear data uncertainty performed for innovative reactor systems shows that the uncertainty in the radiative capture cross section of 238U should be further reduced to 1–3% in the energy region from 20 eV to 25 keV. To this purpose, addressed by the Nuclear Energy Agency as a priority nuclear data need, complementary experiments, one at the GELINA and two at the n_TOF facility, were proposed and carried out within the 7th Framework Project ANDES of the European Commission. The results of one of these 238U(n,γ ) measurements performed at the n_TOF CERN facility are presented in this work. The γ -ray cascade following the radiative neutron capture has been detected exploiting a setup of two C6D6 liquid scintillators. Resonance parameters obtained from this work are on average in excellent agreement with the ones reported in evaluated libraries. In the unresolved resonance region, this work yields a cross section in agreement with evaluated libraries up to 80 keV, while for higher energies our results are significantly higher.

Full text

PHYSICAL REVIEW C 95, 034604 (2017) Neutron capture cross section measurement of 238Uat the CERN n_TOF facility in the energy region from 1 eV to 700 keV F. Mingrone,1,2,3,*C. Massimi,2,3G. Vannini,2,3N. Colonna,4F. Gunsing,5P. ˇ Zugec,6S. Altstadt,7J. Andrzejewski,8 L. Audouin,9M. Barbagallo,4V. B ´ ecares,10 F. Beˇ cv´ aˇ r,11 F. Belloni,5E. Berthoumieux,5,1J. Billowes,12 D. Bosnar,6 M. Brugger,1M. Calviani,1F. Calvi ˜ no,13 D. Cano-Ott,10 C. Carrapic¸o,14 F. Cerutti,1E. Chiaveri,1,12 M. Chin,1G. Cort´ es,13 M. A. Cort´ es-Giraldo,15 M. Diakaki,16 C. Domingo-Pardo,17 I. Duran,18 R. Dressler,19 C. Eleftheriadis,20 A. Ferrari,1 K. Fraval,5S. Ganesan,21 A. R. Garc´ ıa,10 G. Giubrone,17 I. F. Gonc¸alves,14 E. Gonz´ alez-Romero,10 E. Griesmayer,22 C. Guerrero,1A. Hern´ andez-Prieto,1,13 D. G. Jenkins,23 E. Jericha,22 Y. Kadi,1F. K¨ appeler,24 D. Karadimos,16 N. Kivel,19 P. Koehler,25 M. Kokkoris,16 M. Krtiˇ cka,11 J. Kroll,11 C. Lampoudis,5C. Langer,7E. Leal-Cidoncha,18 C. Lederer,26 H. Leeb,22 L. S. Leong,9S. Lo Meo,27,3R. Losito,1A. Mallick,21 A. Manousos,20 J. Marganiec,8T. Mart´ ınez,10 P. F. Mastinu,28 M. Mastromarco,4E. Mendoza,10 A. Mengoni,27 P. M. Milazzo,29 M. Mirea,30 W. Mondalaers,31 C. Paradela,18 A. Pavlik,26 J. Perkowski,8A. Plompen,31 J. Praena,15 J. M. Quesada,15 T. Rauscher,32 R. Reifarth,7A. Riego,13 M. S. Robles,18 C. Rubbia,1,33 M. Sabat´ e-Gilarte,15 R. Sarmento,14 A. Saxena,21 P. Schillebeeckx,31 S. Schmidt,7D. Schumann,19 G. Tagliente,4 J. L. Tain,17 D. Tarr´ ıo,18 L. Tassan-Got,9A. Tsinganis,1S. Valenta,11 V. Variale,4P. Vaz,14 A. Ventura,3M. J. Vermeulen,23 V. Vlachoudis,1R. Vlastou,16 A. Wallner,26 T. Ware,12 M. Weigand,7C. Weiß,22 and T. Wright12 (n_TOF Collaboration) 1European Organization for Nuclear Research (CERN), Geneva, Switzerland 2Dipartimento di Fisica e Astronomia, Universit` a di Bologna, Bologna, Italy 3Istituto Nazionale di Fisica Nucleare, Bologna, Italy 4Istituto Nazionale di Fisica Nucleare, Bari, Italy 5Commissariat ` al’´ Energie Atomique (CEA) Saclay - Irfu, Gif-sur-Yvette, France 6Department of Physics, Faculty of Science, University of Zagreb, Croatia 7Johann-Wolfgang-Goethe Universit¨ at, Frankfurt, Germany 8Uniwersytet Ł´ odzki, Lodz, Poland 9Centre National de la Recherche Scientifique/IN2P3 - IPN, Orsay, France 10Centro de Investigaciones Energeticas Medioambientales y Tecnol´ ogicas (CIEMAT), Madrid, Spain 11Charles University, Prague, Czech Republic 12University of Manchester, Oxford Road, Manchester, United Kingdom 13Universitat Politecnica de Catalunya, Barcelona, Spain 14Instituto Tecnol´ ogico e Nuclear, Instituto Superior T´ ecnico, Universidade T´ ecnica de Lisboa, Lisboa, Portugal 15Universidad de Sevilla, Sevilla, Spain 16National Technical University of Athens (NTUA), Athens, Greece 17Instituto de F´ ısica Corpuscular, CSIC-Universidad de Valencia, Valencia, Spain 18Universidade de Santiago de Compostela, Spain 19Paul Scherrer Institut, Villigen PSI, Switzerland 20Aristotle University of Thessaloniki, Thessaloniki, Greece 21Bhabha Atomic Research Centre (BARC), Mumbai, India 22Atominstitut, Technische Universit¨ at Wien, Wien, Austria 23University of York, Heslington, York, United Kingdom 24Karlsruhe Institute of Technology, Campus Nord, Institut f¨ ur Kernphysik, Karlsruhe, Germany 25Department of Physics, University of Oslo, N-0316 Oslo, Norway 26University of Vienna, Faculty of Physics, Vienna, Austria 27Agenzia nazionale per le nuove tecnologie, l’energia e lo sviluppo economico sostenibile (ENEA), Bologna, Italy 28Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, Italy 29Istituto Nazionale di Fisica Nucleare, Trieste, Italy 30Horia Hulubei National Institute of Physics and Nuclear Engineering - IFIN HH, Bucharest - Magurele, Romania 31European Commission, Joint Research Centre, Retieseweg 111, B-2440 Geel, Belgium 32Department of Physics and Astronomy - University of Basel, Basel, Switzerland 33Laboratori Nazionali del Gran Sasso dell’INFN, Assergi (AQ), Italy (Received 30 November 2016; published 10 March 2017) *[email protected] Published by the American Physical Society under the terms of the Creative Commons Attribution 4.0 International license. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI. 2469-9985/2017/95(3)/034604(14) 034604-1 Published by the American Physical Society F. MINGRONE et al. PHYSICAL REVIEW C 95, 034604 (2017) The aim of this work is to provide a precise and accurate measurement of the 238U(n,γ ) reaction cross section in the energy region from 1 eV to 700 keV. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behavior of the reactor core. In particular, fast reactors, which are experiencing a growing interest for their ability to burn radioactive waste, operate in the high energy region of the neutron spectrum. In this energy region most recent evaluations disagree due to inconsistencies in the existing measurements of up to 15%. In addition, the assessment of nuclear data uncertainty performed for innovative reactor systems shows that the uncertainty in the radiative capture cross section of 238Ushould be further reduced to 1–3% in the energy region from 20 eV to 25 keV. To this purpose, addressed by the Nuclear Energy Agency as a priority nuclear data need, complementary experiments, one at the GELINA and two at the n_TOF facility, were proposed and carried out within the 7th Framework Project ANDES of the European Commission. The results of one of these 238U(n,γ ) measurements performed at the n_TOF CERN facility are presented in this work. The γ-ray cascade following the radiative neutron capture has been detected exploiting a setup of two C6D6liquid scintillators. Resonance parameters obtained from this work are on average in excellent agreement with the ones reported in evaluated libraries. In the unresolved resonance region, this work yields a cross section in agreement with evaluated libraries up to 80 keV, while for higher energies our results are significantly higher. DOI: 10.1103/PhysRevC.95.034604 I. INTRODUCTION In modern society energy has become one among the main fuels for social and economic development. Nowadays, the amount of energy used is massive, and it is destined to rise as population and wealth increase. Needless to say, energyrelated activities have significant environmental impacts. The main and most addressed issue is the emission of greenhouse gas that follows the production of energy through fossil fuels as coal, oil, and natural gas, and which results in serious damage to climate, biodiversity, and human health [1]. To avoid the business-as-usual dependence on fossil fuels, a map of future energy mix that incorporates alternative sources is needed. Several low-carbon resources should be part of this sustainable energy portfolio, and among them nuclear energy seems to be one of the few options available at scale to reduce carbondioxide emissions while providing a baseload generation [2]. In this scenario, the development of improved reactor technologies that will lead to an intrinsically safe nuclear energy production is regarded as a necessary step to ensure a long term sustainable energy supply [3]. Towards this direction, the Generation IV International Forum (GIF) [4] has worked since 2001 to identify and select six nuclear energy systems that will be commercially available by 2030–2040. In addition, the concept of a nuclear subcritical device called accelerator driven system (ADS) is being developed both for energy production and radioactive waste disposal [5]. The research and development of these new reactor concepts require a level of accuracy and precision that challenges the present knowledge of nuclear data. The prediction of the behavior of the reactor cores strongly depends on neutroninduced reaction cross-section data. In this context, the measurement of the 238Uradiative capture cross section is of high priority and is part of the NEA High Priority Request List [6], a compilation of the most relevant nuclear data requirements maintained by the Nuclear Energy Agency of the Organisation for Economic Co-operation and Development (OECD). In fact, 238Uconstitutes more than 90% of nuclear fuel in power reactors, being one of the most important isotopes for neutron transport calculations in the active zone. In particular, for ordinary thermal nuclear reactors the uncertainties on fundamental design parameters such as the multiplication factor, the power peak, and the reactivity coefficient significantly depend on the 238U(n,γ ) reaction cross section for incident neutron energies from 0.0253 eV to 25 keV. Furthermore, the 238Ucapture cross section uncertainty affects the uncertainty of the Pu isotope density at the end of the fuel cycle (1.1% for 239Pu, 0.2% for 240Pu, and 0.1% for 241Pu [7]). The importance of the radiative capture reaction on 238U initiated many measurements of this cross section, mainly at the Oak Ridge Electron Linear Accelerator (ORELA) [8] and at the Geel Linear Accelerator (GELINA) [9] facilities. In particular, an evaluation has been made by Derrien et al. in 2005 including the most significative previous capture and transmission measurements [10,11]. Nevertheless, in the fast region of the neutron spectrum, which is fundamental for fast neutron reactor calculations, inconsistencies between published experimental data can reach 15%, and the most recent evaluations disagree with each other by more than the uncertainties of the standards evaluation by Carlson et al. [12]. In addition, a recent project has started, the Collaborative International Evaluated Library Organization (CIELO) [13], which aims at producing an evaluated library common to Europe, North America and Asia. The focus of this project will initially be on a small number of the highest-priority isotopes, including 238Udue to its key relevance within the nuclear industry. To solve the present inconsistencies and to lower the uncertainty in the cross section down to 1–3% in the energy range from 20 eV to 25 keV, complementary experiments, one at the EC-JRC laboratory GELINA and two at the CERN n_TOF facility, were scheduled within task 1.2 of the FP7 project ANDES of the European Commission [14]. The proposed objective was to combine results from different detection systems and independent experimental principles, obtained from measurements performed independently in different facilities, so as to minimize the overall systematic uncertainty. This work presents the determination of high-accuracy radiative capture cross section of 238U, starting from the measurement performed at the n_TOF facility with an array 034604-2 NEUTRON CAPTURE CROSS SECTION MEASUREMENT OF . . . PHYSICAL REVIEW C 95, 034604 (2017) of two C6D6liquid scintillators, which has been optimized with respect to the background induced by sample-scattered neutrons, and takes advantage of the total energy detection technique. This experimental setup, together with the extremely high instantaneous neutron flux of the n_TOF facility, opens the possibility of measuring the 238Ucapture cross section also for neutron energies above 100 keV, an energy range of extreme interest for new nuclear technologies. In this work the 238U(n,γ ) cross section has been analyzed from 1 eV up to 700 keV. II. EXPERIMENT The measurement was performed at the neutron time- of-flight (TOF) facility of CERN, n_TOF, which became operative in 2001 and has since been at the cutting edge of neutron cross section measurements. The pulsed neutron beam at n_TOF is produced by spallation of 20 GeV/c protons from the CERN Proton Synchrotron accelerator on a water-cooled Pb target. A complete description of the n_TOF facility can be found in Refs. [15,16]. Since the spallation mechanism is a remarkably powerful source of neutrons, the instantaneous intensity of the n_TOF neutron source of ∼2×1015 neutrons/pulse, is one of the highest worldwide. The pulsed neutron source is used together with a moderation system, so that the n_TOF neutron beam covers about eleven orders of magnitude in energy from thermal to GeV. In 2012, when the 238U(n,γ ) measurement was performed, borated water was used as moderator to minimize the production of 2.2-MeV γrays originating from neutron capture in water, which constitutes the main source of background in measurements of capture cross-sections in the keV neutron-energy region. The facility has been designed on the basis of Monte Carlo FLUKA [17,18] simulations, and in particular the neutron source has been fully characterized together with its related γbackground. The measurement takes advantage of the first beam line operative at n_TOF, which is about 200 m long and is designed to clean as much as possible the neutron beam from secondary particles profusely produced in spallation reactions. To this purpose, a sweeping magnet is placed at 145 m from the spallation target to deflect the remaining charged particles in the beam, and the beam tube is embedded in massive iron and concrete shielding to stop particles around the beam pipe. Two collimators 72 and 175 m downstream of the spallation target are used for shaping the neutron beam. For capture measurements the inner diameter of the second collimator is reduced to 1.8 cm to allow for a close geometry between sample and detectors. The first experimental area (EAR1), where the samples and detection systems are placed, is a 7.9 m long room starting at 182.3 m downstream of the spallation target. The neutron beam of the n_TOF facility is constantly monitored by two independent low-background devices, without significantly affecting the neutron beam: the Silicon Monitor (SiMON) [19], with four silicon detectors looking at a 300 μm thick 6Li foil in the beam, and two MicroMegas detectors [20,21], with 235Uand 10Bas neutron converter. The neutron flux of the n_TOF facility for the 2009, 2010, and 2011 campaigns has been evaluated combining five independent measurements performed with different detectors, so as to cover the entire energy range with the highest precision reachable. A detailed description of the method can be found in Ref. [22]. The flux related to this measurement, performed in 2012, was not included in the evaluation procedure, but it has been monitored at the experimental area with SiMON, showing that the shape of the flux has remained constant within 2% (i.e., within uncertainties) between 0.1 eV and 150 keV. In addition, the proton current, used to normalize the total neutron output, has been monitored with the pick-up detection system of the CERN Proton Synchrotron. For capture measurements at n_TOF, two different detection systems are available: a 4πBaF2total absorption calorimeter (TAC) [23] and an array of deuterated benzene liquid scintillator detectors (C6D6detectors). The measurement of this work has been carried out with two C6D6 scintillators placed face to face at 90◦with respect to the beam, 9 mm upstream of the sample: one commercial Bicron and one custom-made developed at Forschungszentrum Karlsruhe (FZK) [24]. Both detectors are optimized to have a very low sensitivity to background signals induced by scattered neutrons. To this purpose the amount of detector material has been minimized, and only materials with low neutron capture cross section have been used. For instance, the window of the photomultiplier is a custom boron-free quartz window, and the housing of the FZK detector is entirely made of carbon fiber. The total energy detection technique has been exploited, combining the detection system described above with the pulse height weighting technique (PHWT) [25] in order to assure the proportionality between the detection efficiency and the total energy released in the capture event. The 238Usample, which has been provided by the EC-JRC laboratory [9], consists of an extremely pure metal plate, 6.125 ±0.006 g in mass, containing less than 1 ppm of 234U, about 11 ppm of 235Uand less than 1 ppm of 236U.The sample is approximately rectangular in shape, with an area of 1621.2±0.1mm 2, and covers about 97% of the neutron beam. The effective area has been determined by an optical surface inspection with a microscope-based measurement system from Mitutoyo [26]. To act in accordance with CERN radio protection regulations, the sample has been encased in ∼60 μm and ∼75 μm thick Al and kapton foils. The effects of this canning have been studied during the measurement campaign by means of dedicated runs and were found to be negligible. The high-quality sample used for the measurement was instrumental for the accuracy of the results obtained. In order to cover the same fraction of the neutron beam, all samples used in this experiment have been chosen with the same dimensions. A summary of the main features of the samples is reported in Table I. The data acquisition system (DAQ) of the n_TOF facility, presented in detail in Ref. [27], is fully digital, flexible, and almost dead-time free. It has been designed based on 8-bit flash-ADCs with sampling rates of up to 2 GHz and 32 Mbyte memory buffer. For the 238U(n,γ ) measurement two channels of Acqiris-DC282 digitizers working at 500 MSamples/sare used per detector. This system corresponds to 96 ms long data 034604-3 F. MINGRONE et al. PHYSICAL REVIEW C 95, 034604 (2017) TABLE I. Characteristics of the samples. Sample Size Mass Atomic density (mm) (g) (atoms/barn) 238U53.825 ×30.12 6.125 ±0.006 (9.56 ±0.04)10−4 natPb 53.77 ×30.19 9.44 1.725 ×10−3 197Au 53.30 ×29.65 9.213 1.773 ×10−3 197Au 53.30 ×29.65 1.547 2.9 ×10−4 natC53.35 ×30.20 28.89 8.94 ×10−2 natC53.35 ×30.20 14.638 4.49 ×10−2 buffers containing digitized signals of the C6D6detectors for neutron energies between 0.02 eV and 20 GeV. III. OPERATION AND PERFORMANCES OF THE EXPERIMENTAL APPARATUS To reach the aim of a precise and accurate 238U(n,γ ) cross section the experimental setup has been precisely characterized, with particular attention to the stability and the performances of the scintillators. Moreover, in the present work we took advantage of the GEANT4 [28] simulation toolkit for the study of the experimental area and of the detection system. A. Stability of the detectors The stability of the apparatus has been monitored with respect to the neutron flux and to the capture detectors. Concerning the neutron flux stability, we investigated the ratio between the counting rate of the silicon monitors and the number of protons derived from the current measurement via the pick-up signal. Runs were selected for further analysis only if this ratio was within 2% of the mean. The stability of the two C6D6detectors has been investigated by looking at the ratio of the C6D6counting rate for different runs in the strongest resonances. This ratio has been recorded bunch per bunch, taking into account the corresponding number of protons. At most, the normalized number of entries per run deviates by about 6% from the mean value, and those runs with percentage deviations greater than 3.5% have been rejected in order to reduce the dispersion of the data set. With this constraint the distribution of the deviation was less than 2% for 90% of the runs. By these conditions we rejected in total 1.5% of the data from the Bicron and 5% from the FZK detector, not significantly affecting the statistics of the measurement. More details can be found in Ref. [29]. B. Amplitude to deposited energy calibration As the PHWT requires the accurate energy calibration of the capture detectors, a careful study of the calibrations between the flash-ADC channels and the deposited energy has been performed on a weekly basis using three standard γ-ray sources: 137Cs (661.7 keV), 88Y(898 keV and 1.836 MeV), and Am/Be (4.44 MeV). The peaks in the amplitude spectra, corresponding to the respective Compton edge of the different γrays, are broadened by the detector resolution. This effect FIG. 1. Calibrated amplitude spectra for 137Cs (Eγ=661.7 keV), 88Y(Eγ=898 keV and Eγ=1.836 MeV), and Am/Be (Eγ= 4.44 MeV) γ-ray sources. The green lines correspond to the broadened simulations, while the black dots are the experimental points. In the inset the different curves for the channel to depositedenergy calibration are shown. needs to be taken into account when extracting the channel numbers associated to the Compton edges, in order to properly calibrate the flash-ADC channels. To this purpose, the GEANT4 simulations of the detector response have been broadened to match the measured spectra. This procedure is important to further check the stability of the detector gain over the whole campaign. Comparing the different calibration spectra for each source we actually noticed a small variation of the gain, which has been adjusted by applying different calibration curves. In Fig. 1the Monte Carlo (MC) simulations of the detector response, broadened by the experimental resolution, are plotted together with experimental data. In the inset of Fig. 1the different calibration lines are shown. For the 238U(n,γ ) measurement the thresholds used for the analysis have been chosen to be Emin dep =0.250 MeV and Emax dep =5.53 MeV, corresponding to the Compton edge of γ-ray energies of 407 keV and 5.77 MeV, respectively. The upper threshold exceeds the neutron separation energy of 239U,Sn=4.806 MeV, by 20% to account for the resolution broadening. C. Weighting functions The PHWT technique requires a mathematical manipulation of the response function of the detection system to achieve proportionality between detection efficiency and deposited energy. To this purpose a weighting function WF(Ed)is defined, and the detector response for different γ-ray energies, which depends on γ-ray transport both in the detection system 034604-4 NEUTRON CAPTURE CROSS SECTION MEASUREMENT OF . . . PHYSICAL REVIEW C 95, 034604 (2017) and within the sample itself, has been simulated by means of the GEANT4 Monte Carlo simulation code. In these simulations, the γrays are emitted randomly within the sample following the Gaussian xy distribution of the neutron beam profile, z being the direction of the neutron beam. The neutron transport within the sample can affect the γ-ray spectrum recorded by the detector and becomes significant only for high values of the product nσtot, where nis the areal density in atoms/barn and σtot is the total cross section. In the present case, where the 238Usample has an areal density n=9.56 ×10−4atoms/barn, this condition is fulfilled only near the peak-energy of the first three s-wave resonances. Since it is not possible to account for this effect, which depends on the cross section to be measured, we produced two different weighting functions for each detector, one considering an homogeneous distribution in the zdirection of the γ-ray emission within the sample, i.e. valid everywhere except for the saturated resonances, and another with an exponential attenuation, valid only in the saturation region of the resonances. The first WF has been used for the resonance shape analysis (RSA) and the analysis of the unresolved resonance region, as well as to weight the background counting rate. The second WF has been applied for the extraction of the normalization factor through the saturated resonance technique [30] (see Sec. IV C). The polynomial dependence of the weighting function WF on the energy deposited by γrays is determined by a leastsquares fit to a number of γ-ray responses in the energy range of interest, i.e., from 250 keV up to 10 MeV. In the calculation the loss of counts due to the discrimination level has been taken into account as discussed in Ref. [25]. IV. DATA REDUCTION The experimental capture yield has been extracted dividing the weighted counts Cw, after correction for the dead time and subtraction of the corresponding background Bw,bythe incident neutron fluence φn[25,31]: Yexp(En)=N Sn+EnA A+1 Cw(En)−Bw(En) φn(En),(1) where Nis the normalization factor, Enthe energy of the incident neutron, Snthe neutron separation energy of the compound nucleus, and Athe mass number of the target nucleus. To achieve proportionality between deposited energy and detection efficiency by the PHWT, means also to take the efficiency of the two C6D6scintillators for capture events into account. Therefore, the normalization factor Nincludes the effective area of the 238Usample intercepted by the neutron beam, which is ∼97%, and the absolute value of the incident neutron flux. A detailed explanation on the technique used to extract the normalization factor will be addressed in Sec. IV C. A. Time-of-flight to energy calibration The neutron velocity and therefore the kinetic energy were derived from the measured time-of-flight and the flight-path length, which is nominally 185 m. The effective flight path FIG. 2. 238U(n,γ ) capture yield compared with the total background and its individual components discussed in the text. The analytical functions which reproduce the beam-related background and the contribution of in-beam γrays are superimposed to the measured components. length L(E) is not a fixed value but depends on the neutron energy according to the neutron flight time distribution in the spallation target and moderator assembly. This energy dependent distribution is also known as the resolution function (RF). For a given energy E, the effective flight path can be split up as the sum of a fixed flight path length L0and an additional component λ(E), which corresponds to the expectation value of the equivalent distance for a neutron of energy E.The value of L0, valid in combination with the used RF obtained by simulations, was fitted with the multilevel multichannel R-matrix code SAMMY [32] using the first five resonances and their corresponding energies. It is important to notice that in this low energy region λcan be considered as a constant. The procedure has been verified with the well known lowenergy s-wave resonances of 197Au as in Ref. [33]. B. Background evaluation and subtraction A precise background subtraction is fundamental for the accuracy desired for this work, as outlined in Ref. [34]. Two different methods were considered for the study of the background, in order to assess its contribution and its uncertainty. Both methods are based on the identification of the individual background components, either determined through dedicated measurements or extrapolated from background measurements with the use of MC simulations. In Fig. 2the 238Ucapture yield is shown together with the background decomposed into the different contributions. The total background has been calculated as B=CU BO +FEF −CEF BO+finBFγ-inB +SNS +Sfiss.(2) 034604-5 F. MINGRONE et al. PHYSICAL REVIEW C 95, 034604 (2017) The time independent source of background CBO comes from natural and sample radioactivity, and from air activation. Because this contribution turned out to be sensitive to the position of the sample on the vertical ladder of the sample changer, it has been routinely studied with different beam-off measurements corresponding to the different positions of the samples. This contribution dominates for low energies up to few eV. The main component of the beam-related background has been evaluated without any sample in beam, in order to take all sources of background in the experimental area into account that are not related to the presence of the sample. In order to avoid statistical fluctuations, the resulting shape, as a function of TOF, has been fitted with an analytical function based on a sum of parametrized exponentials [FEF in Eq. (2)], and an uncertainty of 5% has been associated to that function. The beam-related background due to in-beam γrays, although strongly suppressed by the borated water moderator, plays an important role in the keV energy region. Its shape can be deduced by means of a n+natPb measurement properly subtracted by beam-off and sample-out contributions. The difference in areal density between uranium and lead sample as well as the different charge number were taken into account as a scaling factor [finB in Eq. (2)], obtained through GEANT4 Monte Carlo simulations using the implemented geometry for the calculation of the weighting functions. The initial in-beam γ-ray distribution has been provided by Monte Carlo FLUKA simulations (see Ref. [16] for more details about the simulated γ-ray spectra in the experimental area). To avoid statistical fluctuations the analytical form of this background has been calculated and was fitted to the measured spectrum of Pb after applying the scaling factor obtained with the simulations [Fγ-inB in Eq. (2)]. Another source of background for (n,γ ) measurements is related to the detection of γrays coming from sample-scattered neutrons captured in the ambient material. This background follows the same energy dependence as the true capture events and may therefore compromise the analysis of resonances. To properly evaluate it, GEANT4 simulations have been performed with a complete description of the geometry of the experimental area. All the details of the procedure can be found in Ref. [35]. The output of the simulation has been analyzed using the same conditions as for the experimental data [SNS in Eq. (2)]. The same simulations have been used to evaluate the contribution of γrays coming from fission events [Sfiss in Eq. (2)]. They can be due to prompt γrays and γrays from the decay of fission-fragment. We used the models and data sets as reported in Ref. [35], which for 238Uprovide data only up to 20 MeV. Therefore we had to account for the missing part of the neutron spectrum with a scaling procedure, assuming that the shape of the γbackground coming from fission events does not change with increasing energy. We multiplied the reference 238U(n,f ) cross section from Ref. [36] with the simulated n_TOF neutron flux to obtain an estimated count rate, and we scaled the simulated background for the ratio between the integral of the expected count rate up to 20 MeV and up to 1 GeV. The overall background is dominated by the general background, independent of the sample itself. Only in the unresolved resonance region (URR) above about 10 keV the FIG. 3. Background yield in the URR obtained by summing the individual background components shown in Fig. 2(red dots) and by using the black-resonance filters in the neutron beam (blue circles). The bottom panel shows that the ratio deviates by less than 5% from unity, except in the neighbourhood of the two big Al resonances at 34.23 and 84.27 keV, because the amount of aluminum in the windows of the beam line was not precisely known. in-beam γrays start to contribute a comparable fraction. All other background components are of minor importance. The favorable signal/background ratio in the resolved resonance region (RRR) is shrinking at higher energies but remains always better than 2 : 1 throughout the URR. To validate the level of the background in the URR we exploited measurements with Ag, W, Co, and Al black resonance filters in beam [31]. The shape of the time-dependent background has been evaluated in a n+natPb measurement, and the beam-off contribution was added in order to obtain the complete background function. The resulting background has been properly scaled to reproduce the background during the measurement according to the procedure introduced by Aerts et al. [37]. In particular, the total background, in counts per log-equidistant time-of-flight bin, can be reproduced by the function B(t)=atb+k1 k2(t)Pb(t),(3) where atbreproduces the constant beam-off background, with bfixed to 1 because of the units of B(t). To take into account the attenuation of both the neutron beam and the in-beam photons, two scaling factors have been identified: a time-independent factor k1to scale the contribution of n+natPb without filters to the n+238Uwith filters, and a time-dependent factor k2(t) to take the attenuation of the in-beam γrays by the filters into account. The time-dependence reflects the fact that the relative intensities of the in-beam γrays change with time-of-flight. As shown in Fig. 3, the background yields agree for 3 < En<100 keV within less than 5% except for energies in the 034604-6 NEUTRON CAPTURE CROSS SECTION MEASUREMENT OF . . . PHYSICAL REVIEW C 95, 034604 (2017) TABLE II. Summary of the correlated uncertainties in the 238U(n,γ ) cross section measurement. The uncertainties on the neutron flux shape are from Ref. [22]. Source of uncertainty Uncertainty RRR Uncertainty URR Uncertainty URR (3 <E n<100 keV) (En>100 keV) Sample mass 0.1% 0.1% 0.1% Neutron flux - shape 1–2% 4–5% ∼2% Normalization 1% 1% 1% Background subtraction 1–2% 3% ∼7% Total 2–3% 5–6% 8% neighbourhood of the two strong Al resonances at 34.23 and 84.27 keV. For neutron energies above 100 keV, it is impossible to determine the background with the Al filter reliably because of the increasing resonance structure of the Al cross section. C. Capture yield normalization The experimental capture yield has been internally normalized to the peaks of the first three well-isolated saturated resonances at 6.67 eV, 20.9 eV, and 36.7 eV. Since nσtot 1 at the resonance peak, all the incident neutrons with energies close to the resonance interact with the sample and therefore the effects of neutron transport cannot be neglected in the region of a saturated resonance. For this reason the weighting function that includes an exponential attenuation within the sample has been used. A spectrum with a weighting function was also calculated for homogeneous γ-ray production inside the sample, corresponding to nσtot 1. The ratio of the weighted spectra obtained with the two weighting functions deviated from unity by less than 0.5%. For this reason we neglected the energy-dependent yield correction as in Ref. [38]. The normalization factor Nin Eq. (1) has been extracted via the saturated resonance method, evaluating the expected capture yield through a least-squares adjustment of the experimental data with the SAMMY code [32]. Because an internal normalization is applied, i.e., exploiting a resonance of the nucleus under investigation, the systematic uncertainties due to changes in the experimental conditions are significantly reduced. The two detectors have been treated separately, and for each one the final normalization factors have been chosen as the average of the three resonances. The mean deviation of these factors of 1% has been adopted as the normalization uncertainty. D. Discussion of uncertainties The total uncertainty in the 238U(n,γ ) cross section is a combination of several components related to the sample characteristics and the analysis procedure. Along with the uncorrelated uncertainty due to the counting statistics, correlated uncertainties are involved as well. The uncertainty related to sample characterization is almost negligible since the sample mass has been determined at the EC-JRC with an accuracy of about 0.1%. An important source of correlated uncertainty is the yield normalization. As discussed in Sec. IV C, the uncertainty in the normalization factor is reduced to less than 1% by the internal normalization. This correlated uncertainty component has to be combined with the uncertainty of the neutron flux shape between 1 and 5%, depending on neutron energy [22]. The uncertainty related to the background subtraction propagates to the final capture yield in correlation to the signal-to-background ratio, and it depends on the energy range considered. Within the RRR the signal to background ratio varies from a factor of 4 to a factor of 100, depending on the strength of the resonance. In the URR the signal to background ratio is about a factor of 2, resulting in a 3% uncertainty of the background subtraction for 3 <E n<100 keV. For higher energies from 100 to 700 keV the level of the background strongly depends on the γ-ray component, which has been estimated from MC simulations. An uncertainty of ∼7% has been attributed to the background level for this energy range. The estimation of the uncertainty has been based on the comparison between the GEANT4 full simulations (i.e., considering all background contributions) and the experimental data for 197Au. The agreement between the two, within a few percent, provided confirmation of the level of accuracy of the simulated background. In Table II all the correlated uncertainties are listed for the different energy ranges. V. R E S U LT S A. Resolved resonance region The energy resolution of the n_TOF spectrometer gives an upper energy limit of 20 keV to the RRR, since the experimental broadening becomes comparable with the level spacing. However, due to the decrease of the signal-to- background ratio with neutron energy together with the limited counting statistics, resonances could be reliably resolved only up to 3 keV. Within this energy region a resonance shape analysis has been performed by means of the SAMMY code [32]. The theoretical reaction yield is obtained through the Reich-Moore approximation of the multilevel R-matrix formalism, and convoluted with the experimental resolution. This latter is implemented in SAMMY via a numerical description derived from Monte Carlo FLUKA simulations. Moreover, the code includes the corrections for multiple-scattering effects and uses 034604-7 F. MINGRONE et al. PHYSICAL REVIEW C 95, 034604 (2017) FIG. 4. Statistical distribution of resonance kernel ratios of this work over JEFF-3.2 and this work over ENDF/B-VII.1. The gaussian best-fit curve is also plotted as a dashed line. the free-gas model to take the Doppler broadening due to thermal motion of atoms inside the sample for an effective temperature of 305 K into account, according to the room temperature which was continuously monitored during the measurement [31]. The resonance parameters (i.e., the capture width γand the neutron width n) are determined by a least-square fit to the experimental data, while the resonance spins are taken from literature. In this work, starting from initial values taken from the JEFF-3.2 library [39], only the smaller parameter, either γor n, has been left free in the fitting procedure. In a few cases both partial widths were left free to improve the description of the resonance shape analysis. The results from this work have been compared with the evaluated data libraries JEFF-3.2 [39] and ENDF/B-VII.1 [40]. The ratio of kernels [defined as κ=gnγ/(n+γ)] from this work to the ones obtained from evaluated parameters from JEFF-3.2 and ENDF/B-VII.1 has been studied as a function of resonance energy to test the accuracy of the measurement. Because of the large number of measurements carried out so far and the effort spent in producing an accurate 238U(n,γ ) evaluation, significant deviation from the evaluated data are not expected. As can be seen in Fig. 4, the statistical distributions are found to be Gaussians centered at 0.99 and 1.00, respectively, both with a standard deviation of 0.06, showing the excellent agreement between data from this work and evaluated libraries. The measured capture yield together with the SAMMY best-fit curve is shown in Fig. 5. Below 1.5 keV, the JEFF-3.2 and ENDF-B/VII.1 libraries present sizable differences for some resonances. In this energy region, there are two resonances from this work, at 721.68 eV and 1211.31 eV, respectively, which strongly differ from those indicated in the ENDF/B-VII.1 library, while they are in good agreement with JEFF-3.2. In particular, the ENDF/B-VII.1 evaluation gives γ=3.15 meV and 6.6 meV for these resonances, whereas JEFF-3.2 reports γ=23.0 meV and γ=17.55 meV, respectively. As can be seen in Fig. 6,the partial widths obtained from this work are in agreement with the ones reported by JEFF-3.2. Nevertheless, the difference with ENDF/VII.1 can be explained to some extent with a different treatment of the fission contribution [41,42]. Residual systematic effects related to neutron scattering or to the resonance strength have been evaluated studying kernel ratios as a function of the ratio gn/ γand of the resonance kernel itself. In the former case, no evidence of systematic effects are visible as expected from the optimized detection set-up used. Regarding effects due to the resonance strength, it has been seen that for weak resonances, characterized by very small kernels (κ⩽2.3 meV), resonance parameters obtained from this work are systematically larger than the evaluated ones. Despite the low strength of these resonances, three of them are in the low energy region, ER=145.66,311.35,488.89 eV, where the statistics is very high. The fitting procedure is therefore quite accurate, and Fig. 7shows that data from this work are actually higher than what is predicted by using the JEFF-3.2. parameters The same conclusion can be drawn for the resonance at ER=1565.54 eV, a stronger resonance, which is ∼27% higher than predicted from JEFF-3.2 parameters. The kernels of critical resonances obtained from this work are compared with the evaluated parameters in Table III. B. Unresolved resonance region As the experimental conditions are limiting the energy region where the cross section can be analyzed through a RSA to about 3 keV, the capture cross section at energies up to 700 keV is obtained from the measured yield by applying a correction factor determined from average parameters. To extract the cross section the thin-sample approximation Y≈nσγis used. At high energies, in fact, the total cross section becomes quite low (σtot ∼1 b) so that the areal density n=9.56 ×10−4at/b is sufficiently low to fulfill the condition nσtot 1. The sample-related effects, i.e., self-shielding and multiple scattering followed by capture, are taken into account applying a correction factor obtained from Monte Carlo simulations. TABLE III. Resonance kernels (κ)for238U+ncalculated from parameters obtained from this work, and from ENDF/B-VII.1 and JEFF-3.2 libraries. ER(eV) This work ENDF/B-VII.1 JEFF-3.2 κ(meV) κ/κ (%) κ(meV) κ(meV) 145.66 0.93 ±0.02 2 0.85 0.85 311.35 1.14 ±0.04 3 1.01 1.00 488.89 1.0 ±0.4 44 0.83 0.83 721.68 1.45 ±0.09 6 1.12 1.36 1211.32 6.5 ±4 61 4.01 6.54 1565.54 6.1 ±0.7 12 4.71 4.71 034604-8 NEUTRON CAPTURE CROSS SECTION MEASUREMENT OF . . . PHYSICAL REVIEW C 95, 034604 (2017) FIG. 5. Experimental capture yield for 238U(n,γ ) with a resolution of 5000 bin/decade. The SAMMY calculation based on JEFF-3.2 [39] resonance parameters is represented by the solid line. 034604-9