scieee AI-readable full text Open interactive document viewer

Reducing the energy demand of multi-dwelling units in a Mediterranean climate using solar protection elements

León-Rodríguez, Ángel Luis; Domínguez Amarillo, Samuel; Campano, Miguel Ángel; Ramírez Balas, Cristina

Abstract

It is known that glazed openings are very important elements in the energetic behavior of buildings, especially in Mediterranean climates where there are many hours of solar radiation. The objective of this study was to determine the influence of solar protection on the energy demand of public housing structures in these climates. To this end, the reduction in energy demand achieved by fixed solar protectors in combination with mobile protectors (blinds) was quantified, including an evaluation of the influence of their geometry, dimensions, degree of openness, and the orientation of the opening. To analyze and quantify energetic demand, a block of public housing units in a neighborhood of Seville (latitude 37°23' N) was used as a model. This block is typical of public housing in the Mediterranean region. Simulated energetic models were created using DesignBuilder, achieving reductions in the annual energy demand from 10% to 27% according to the orientation chosen. The results and conclusions of the study are applicable to new construction, energetic rehabilitation projects, and/or the improvement of existing buildings

Full text

Energies 2012, 5, 3398-3424; doi:10.3390/en5093398 energies ISSN 1996-1073 www.mdpi.com/journal/energies Article Reducing the Energy Demand of Multi-Dwelling Units in a Mediterranean Climate Using Solar Protection Elements Ángel L. León *, Samuel Domínguez, Miguel A. Campano and Cristina Ramírez-Balas Institute of Architecture and Building Science, University of Seville, Avenida Reina Mercedes No.2, 41012 Seville, Spain; E-Mails: [email protected] (S.D.); [email protected] (M.A.C.); [email protected] (C.R.-B.) * Author to whom correspondence should be addressed; E-Mail: [email protected]; Tel.: +34-954-55-95-17; Fax: +34-954-55-70-24. Received: 30 June 2012; in revised form: 1 August 2012 / Accepted: 15 August 2012 / Published: 6 September 2012 Abstract: It is known that glazed openings are very important elements in the energetic behavior of buildings, especially in Mediterranean climates where there are many hours of solar radiation. The objective of this study was to determine the influence of solar protection on the energy demand of public housing structures in these climates. To this end, the reduction in energy demand achieved by fixed solar protectors in combination with mobile protectors (blinds) was quantified, including an evaluation of the influence of their geometry, dimensions, degree of openness, and the orientation of the opening. To analyze and quantify energetic demand, a block of public housing units in a neighborhood of Seville (latitude 37°23' N) was used as a model. This block is typical of public housing in the Mediterranean region. Simulated energetic models were created using DesignBuilder, achieving reductions in the annual energy demand from 10% to 27% according to the orientation chosen. The results and conclusions of the study are applicable to new construction, energetic rehabilitation projects, and/or the improvement of existing buildings. Keywords: solar protection; energy demand; energy efficiency; energy saving; social housing buildings; building design OPEN ACCESS Energies 2012, 5 3399 1. Introduction This study is part of the Research, Development and Innovation project known as Efficacia, financed by the Andalusian Government and by companies in the construction sector, with an overall objective of reducing the energy consumption and environmental impact of public housing in southern Spain [1]. To achieve this objective, the project has analyzed the incidence of each thermal envelope component in a block of public housing units with an enclosed courtyard. This methodology has involved activities planned in several stages, and the housing block has been the subject of a broader energetic description project. The first phase of this project was to monitor this housing building under real occupation conditions, with the goal of analyzing and creating parameters for energetic consumption and demand over the course of two years. This first phase was accompanied by a series of surveys regarding the consumption habits of the renters [2]. In the second phase, the reduction in energetic demand through modification of the exterior envelope components (passive systems) was evaluated [3]. The third and final phase centered on the control and automation of ventilation using active systems and solar protection elements. This final phase is the subject of this article, in particular, the influence of façade solar protection elements on the energetic demand of the analyzed housing units. Façade solar protection elements are known to play a relevant role in the energetic demand of buildings because they have a large influence on one of the factors that greatly impacts this demand: solar radiation. There are many published architectural studies on solar protection elements [4–7]. In general, the majority of these studies focused on the influence of façade solar protectors on light regulation, and thus, solar protectors were discussed in the context of natural lighting [8]. However, the study of Jaber et al. [9], similar to the present work, is focused on the variation of the energy consumption through the use of different types of orientation of the building, window sizes and thermal insulation thickness, for typical residential buildings located in the Mediterranean region. They concluded that, using best orientation, optimum size of windows and shading devices, and optimum insulation thickness in dwellings, energy annual consumption can be reduced by about 27.59%. There are studies in the field of energy that use simple, generic models of a rectangular parallelepiped enclosure containing only one window. The objective of these is to determine the optimal angle for the slats in a horizontal overhang, using only latitude as a variable [10]. In the case of housing units, the work of Chan et al. [11], in which the percentages of total energy savings achieved by a climate control system in a typical Hong Kong dwelling were sampled, is especially important. Using simulation models, Chan studied the energetic consumption of the typical dwelling with and without solar protection elements (balconies) in different orientations. In Mediterranean climates, studies of energy savings using rectangular dwelling models that are 3 × 4 × 3 m (width × length × height) [12] are also worth examining. Among the studies that have analyzed the influence of certain types of solar protection on the interior thermal environment (operative and radiant temperature), we highlight those of Bessoudo et al. [13]. They performed experimental measurements of an office building located in Montreal using two types of solar protection: rolling-type cloth shades and horizontal aluminum blinds. This study, applicable to office enclosures with two thirds of the south-facing façade composed of glass, was later complemented by another study of which the objective was to quantify the capacity of different types Energies 2012, 5 3400 of glass, with varying thermal resistance and solar factors, to achieve interior thermal comfort in this type of space [14]. Lee and Tavil [15] studied the total energy demand and peak consumption in office buildings by analyzing the influence of horizontal overhangs. They varied dimensions and position relative to the window for the different ratios of glazing surface to total façade area in Chicago (41°50' N) and Houston (29°46' N). This study uses a real housing unit of which the initial energetic behavior has been contrasted and validated to generate a base model of the behavior and evolution of energy demand. The two most common types of solar protection were used: (a) horizontal overhangs above the openings (HO), simple (Ss) and double (Sd) side fins, and protections combining overhangs and side fins (BX); and (b) fixed and mobile horizontal louvres (L) and mobile exterior blinds (B). Independent of the existence of some type of exterior solar protection, in Mediterranean dwellings, the use of opaque blinds or some other form of external shading (e.g., Roman-type shades or Venetian blinds) is very widespread, therefore, this study examined the potential reduction in energetic demand by combining several types of fixed solar protector elements with the usual mobile ones (blinds), to more closely reflect reality. Energetic demand is defined as the useful energy required for maintaining the interior of the dwelling within the indicated temperature conditions and hours of use. Based on different theoretical models, the energetic influence and the energy saving potential of solar protection elements were analyzed for facades in the four cardinal directions. The results shown are representative of buildings in housing units with glazed openings that constitute approximately 20% of the total façade surface and with windows that have an average height of 1.2 m (typical parameters in public housing dwellings in the Mediterranean area). 2. Description of the Studied Climate and Building The building studied, Cros-Pirotecnia, is a multi-dwelling block located in Seville (Spain), with an enclosed courtyard (Figure 1) containing 218 dwellings, retail units, and a garage. This building, developed by the Municipal Housing Company of Seville, was built in 2005. All the dwellings are rental units, with an average usable area of 58 m2. The total building surface area is 5216 m2. Figure 1. Aerial view of the studied building. Energies 2012, 5 3401 2.1. Weather Data Seville, located in southern Spain, (37°25' N) (5°54' W), has a Mediterranean climate, corresponding to Csa in a Koppen climate classification, and its altitude is 6–7 msnm above sea level. The climatic profile was obtained from an EnergyPlus weather file (EPW), developed by the U.S. Department of Energy. The file selected for Seville, SEVILLA SWEC (Spanish Weather for Energy Calculations) was created from data originating from Luis Pérez-Lombard at the Spanish National Institute of Meteorology. The climate is characterized as B4 climatic severity (Spanish National Climatic Zonification for Energy Savings, CTE DB-HE1), with mild winters and hot summers [16]. 2.2. Study Site A typical dwelling, consisting of two bedrooms, a living room, a bathroom, and a kitchen, was used as the geometric, functional, and energetic model (Figure 2). The bedrooms each had glazed windows with dimensions of 1.20 m × 1.20 m (width × height), and the dining room had one window measuring 1.80 m × 1.20 m. Figure 2. Floor plan of the typical dwelling unit studied. 2.3. Structural Conditions The structural elements of the thermal envelope and interior partitions were typical for this type of building. The surface mass, thermal transmittance (U), and solar factors (in this case, of the windows) are shown in Table 1. All dwelling unit windows were of the sliding type and were single pane, 6 mm in thickness (Ug = 5.40 W/m2K), with metal aluminum frames without a thermal break (Uf = 5.88 W/m2K). All windows had external blinds that modified the global thermal effects of the opening. As previously shown [17], the use of these elements reduces both thermal transmittance and the solar factor of the window. In the series of simulations for the HO, BX, Sd, Ss, and L solar protectors, both parameters were corrected to obtain the most realistic results for energy demand. When the only solar protection was the blind itself (series B), the original transmittance (U) and solar factor (g┴) for the opening were assumed to not duplicate their reductive effects. Energies 2012, 5 3402 Table 1. Envelope description. Element Weight per unit area (kg/m2) Transmittance U (W/m2K) Solar factor Façade 176 0.81 - Roof 728 0.49 - Diving wall 189 1.54 - Partition 25 1.79 - Floor 519 2.02 - Glazing with solar protection: series HO, BX, Sd, Ss and L with solar protection: series B 4.64 0.66 5.40 0.82 The thermal transmittance and solar factor modified by the presence of window blinds were obtained adopting the average approximation included in the Spanish Official Energy Demand Limitation procedure (LIDER) [18–20] [Equations (1)–(3)], for an average modification value for the transmittance (U) and solar factor (g┴) due to the partial action of the elements distributed among the various façades (a window coverage of 30% is understood): Umod = Uorig·FactorU (1) FactorU = 0.70 + [0.30/(1 + 0.165 × Uorig)] (2) g┴mod = g┴orig·Factorg; Factorg = 0.8 (3) 3. Description of the Methodology 3.1. Energy Models The energy simulation models were generated and evaluated using DesignBuilder (Version 2.3.6.005). To analyze the influence of balconies, a very typical architectural element in this type of building, two typical dwelling models were used, with and without balconies. In Figure 3, both models are shown, with the dwelling unit studied in this paper highlighted using a darker color. Figure 3. (a) M1: Models with and (b) M2: without a balcony. (a) (b) Before continuing with the energy simulation, the energetic base models used in the study were developed after a calibration and validation process. Calibration of the models was done during the Energies 2012, 5 3403 Efficacia project by tuning the energetic simulation models, supported by an 18 months monitoring, energy consumption and inhabitants behavior campaign in the control dwellings, as described in [1–3]. The usage and operation variables for the dwelling were previously described in [3]. The model construction accounted for the units and spaces adjacent to the model dwelling unit. The adjacent habitable spaces had usage and operation conditions similar to the model unit. The non-habitable spaces and community areas had null occupation and standard lighting and ventilation conditions. The models were considered free of shadows produced by exterior elements (vegetation and/or nearby buildings), as is frequently seen in dwellings situated in the upper stories of these buildings. The shadows projected by parts of the building itself (jutting elements and laundry-terraces) were included in the analysis. For the effects of the energetic demand simulations for each hypothesis, the model unit was considered thermally treated for winter and summer. The influence of natural lighting conditions in the spaces was not considered in the results. 3.2. Solar Protection Series Six series of solar protection elements (Table 2 and Figure 4) were considered to evaluate their influence on the energetic demand of the model dwelling unit in its two modes (with and without balcony). Each series was coded with letters and numbers according to the dimensions and variables of each protection type. Fixed protections, such as horizontal overhangs (HO), vertical side fins (Ss and Sd), and their combination (BX), were analyzed while varying their primary dimensions. The mobile protection elements (L and B) were studied while varying their dimensions, grade, and opening schedule. Table 2. Series of solar protectors studied. Series Type of Protection (variables parameters) Variables of the solar protection coding HO Overhang (L, W, H) L = depth of horizontal element (m) W = lateral extension (m) H = height over opening lintel (m) D = depth of vertical element (m) α = louvre angle (degrees over horizontal) I = vertical separation between louvres (cm) % = opening percentage (0:closed; 50:middle; 100:open) T = timing schedule (see Table 3) BX Box type protection (L, D, H) Sd Double side fin (D, H) Ss Simple side fin (D, H) L Horizontal louvres (α, I, %, T) B Blinds (%, T) The different protection series were available for all of the windows in habitable spaces (living room, bedrooms, and kitchen). When the model dwelling unit was studied with the balcony included for the living room-dining area (model M2), no additional protection for its openings was considered, aside from the effect of the balcony itself. Because all windows were on the same face (single orientation), each simulation analyzed one type of solar protection for all windows. Mobile solar protection elements (series L and B) were studied with automatic opening controls based on incident solar radiation; this function was guided by the schedule indicated in Table 3. Energies 2012, 5 3404 Figure 4. Geometric dimensions of the solar protection elements. Table 3. Annual timing schedule for louvres and blinds according to orientation. 3.3. Geometric Optimization of Protections Because of the different seasonal sun elevations for the 12 hours of daylight, the approach shown in Figure 5 was followed to optimize the depth (L) and height (H) of the horizontal protection elements of the HO and BX series. The longest and shortest values for (L) were established through two optimization processes: (i) Optimization by summer and winter solstice: Lines were drawn at the angle of solar incidence of the summer and winter solstices in relation to the interior face of the opening; the intersection point of both lines provided the optimal height of the protection element with respect to the opening lintel (H) and its minimum length (L) (H = 0.08 m and L = 0.19 m for an opening of 1.2 m in Seville). For Facing Timing schedule Timing 0 Year-round Timing 1 Summer (May to September) Timing 2 Summer (May to September) Timing 1 and 2Winter (October to April) North 0:00 to 24:00 % Closed 00:00 to 24:00 % Closed 00:00 to 10:00 Opened 00:00 to 24:00 Opened 10:00 to 22:00 % Closed 22:00 to 24:00 Opened South 0:00 to 24:00 % Closed 00:00 to 24:00 % Closed 00:00 to 10:00 Opened 00:00 to 24:00 Opened 10:00 to 18:00 % Closed 18:00 to 24:00 Opened East 0:00 to 24:00 % Closed 00:00 to 24:00 % Closed 00:00 to 09:00 Opened 00:00 to 24:00 Opened 09:00 to 15:00 % Closed 15:00 to 24:00 Opened West 0:00 to 24:00 % Closed 00:00 to 24:00 % Closed 00:00 to 15:00 Opened 00:00 to 24:00 Opened 15:00 to 22:00 % Closed 22:00 to 24:00 Opened Energies 2012, 5 3405 12 hours of daylight, this overhang allowed the complete entry of all solar radiation during the winter solstice and projected complete shade during the summer solstice. For the days in between, the sun entered the opening according to its height relative to the horizon. (ii) Optimization by winter solstice and equinoxes: To obtain greater solar control of the opening, two lines for the winter solstice and the spring/fall equinoxes were drawn. Their point of intersection denoted the height of the overhang from the window lintel (H) and its maximum length (L) (1.29 m and 0.86 m, respectively). During the 12 hours of daylight, this protection projected shade over the entire opening from the spring equinox until the autumn equinox, impeding increases in thermal gains due to solar radiation during times of demand for cooling. After this moment, the opening began to fall under sunlight till the winter solstice, when solar incidence was at a maximum level. Figure 5. Determining the maximum and minimum length of the overhangs and lateral fins. To determine the influence of the (L) and (H) dimensions, three additional positions intermediate to those above were used, as shown in Figure 5. The (W) dimension for the HO protections was fixed to guarantee shade during the least favorable summertime hours. For this, the stereographic solar chart for Seville was used. With the goal of simplification, the (W) dimensions for the solar protections were designed to be symmetrical with respect to the opening and varied according to each half hour of daylight. Energies 2012, 5 3406 4. Analysis of Results 4.1. Energetic Demand of the Model Dwelling in Its Original State Before analyzing the energetic influence of the different types of solar protection, in Figure 6, the favorable (winter) and unfavorable (summer) impacts of thermal gains from solar radiation through the openings for the model dwelling unit in the two modes (with and without balcony) are shown. The values are shown for a south-facing model unit. In the same manner, in Figure 7, the annual thermal demands (kWh/m 2 ) for the model dwelling unit based on geographic orientation are shown. Figure 6. Annual contribution of solar gains in the original dwelling unit (south-facing). Figure 7. Annual thermal demand by geographic orientation. The presence of balconies on the façade mostly reduced the demand because the balcony provided optimized solar protection for blocking radiation during the summer, whereas its geometry and dimensions allowed for the benefits of radiation during the cold months. The presence of the balcony created a reduction in demand for the original unit (OU). This reduction was greatest in the south-facing orientation (8.36%) and least when facing west and north (−1.75% and −1.43%), with the eastern façade having a non-significant effect. Energies 2012, 5 3413 Appendix 1 Table A1. Envelope description. Element Composition Transmittance (W/m2K) Façade ½ foot face brick + PUR Insulation + Air chamber + Plasterboard cladding. 0.81 Roof Gravel + XPS Insulation + Lightweight aggregate concrete + Concrete waffle slab + Plaster coating. 0.49 Diving wall Plaster coating + Low density ceramic block + Plaster coating. 1.539 Partition Plaster coating + Ceramic brick + Plaster coating. 1.79 Floor Plaster coating + Concrete waffle slab + Cement mortar + Artifical stone. 2.024 Glazing Thickness Frame Single glass 6 mm Aluminum windows frame without thermal break Table A2. Protocols used for the demand calculations. Activity Value Schedule Winter Summer Occupation 0.056 pers/m2 00:00 to 07:00 07:00 to 16:00 16:00 to 23:00 100% 25% 50% 00:00 to 07:00 07:00 to 16:00 16:00 to 23:00 100% 25% 50% Weekends & holidays: 00:00 to 24:00 50% Weekends: 00:00 to 24:00 Holidays: 00:00 to 24:00 100% 0% Equipment & Lighting 4.44 W/m2 +4.44 W/m2 00:00 to 08:00 08:00 to 19:00 19:00 to 20:00 20:00 to 23:00 23:00 to 24:00 10% 30% 50% 100% 50% 00:00 to 08:00 08:00 to 19:00 19:00 to 20:00 20:00 to 23:00 23:00 to 24:00 10% 30% 50% 100% 50% Infiltration 1 ac/h 00:00 to 24:00 100% 00:00 to 24:00 100% Ventilation 3 ac/h 00:00 to 24:00 0% 00:00 to 08:00 08:00 to 24:00 100% 0% Operative set-point temperature 00:00 to 16:00 16:00 to 23:00 23:00 to 24:00 - 20 °C - 00:00 to 08:00 08:00 to 23:00 23:00 to 24:00 - 26 °C - Notes: Winter: from last Sunday in October to last Saturday in March; Summer: from last Sunday on March to last Saturday on October. Data obtained from CAPALYC document [19]. When building the study model in the program to make the nodal calculation, it is necessary to create the boundary conditions, i.e., the spaces with which the complete dwelling makes contact, they are:  The dwelling on its left (same floor);  The dwelling on its left (same floor);  The dwelling immediately above;  The dwelling immediately below;  Access corridor and common areas. Energies 2012, 5 3414 The characteristics of these spaces will be the same as the study location, except the hall, which represents an area without air conditioning and zero occupation and activity. The boundaries of these adjacent areas, which are the exterior and the other dwellings. The latter connection is represented by adiabatic partitions, since the energy exchange with these other rooms is not of great relevance, given the predominance of energy flows to the exterior via the envelope compared to those that occur between the partitions. Appendix 2 Figure A1. BX Series: Annual thermal demand. Energies 2012, 5 3415 Figure A1. Cont. Figure A2. HO Series:Annual thermal demand. Energies 2012, 5 3416 Figure A2. Cont. Energies 2012, 5 3417 Figure A2. Cont. Figure A3. Sd Series: Annual thermal demand. Energies 2012, 5 3418 Figure A3. Cont. Energies 2012, 5 3419 Figure A3. Cont. Energies 2012, 5 3420 Figure A4. Ss Series: Annual thermal demand. Energies 2012, 5 3421 Figure A4. Cont. Energies 2012, 5 3422 Figure A5. L Series: Annual thermal demand.