Full text
energies Article Assessment of a Universal Reconfiguration-less Control Approach in Open-Phase Fault Operation for Multiphase Drives Federico Barrero 1,* , Mario Bermudez 2, Mario J. Duran 3, Pedro Salas 3and Ignacio Gonzalez-Prieto 3 1Electronic Engineering Department, University of Seville, 41092 Sevilla, Spain 2Electrical and Thermal Engineering Department, University of Huelva, 21007 Huelva, Spain; [email protected] 3Electrical Engineering Department, University of Málaga, 29071 Málaga, Spain; [email protected] (M.J.D.), [email protected] (P.S.), [email protected] (I.G.-P.) *Correspondence: fbarrer[email protected]; Tel.: +34-954-48-13-04 Received: 7 November 2019; Accepted: 5 December 2019; Published: 10 December 2019 Abstract: Multiphase drives have been important in particular industry applications where reliability is a desired goal. The main reason for this is their inherent fault tolerance. Different nonlinear controllers that do not include modulation stages, like direct torque control (DTC) or model-based predictive control (MPC), have been used in recent times to govern these complex systems, including mandatory control reconfiguration to guarantee the fault tolerance characteristic. A new reconfiguration-less approach based on virtual voltage vectors (VVs) was recently proposed for MPC, providing a natural healthy and faulty closed-loop regulation of a particular asymmetrical six-phase drive. This work validates the interest in the reconfiguration-less approach for direct controllers and multiphase drives. Keywords: multiphase induction motor drives; natural fault tolerance; virtual voltage vectors 1. Introduction The use of variable-speed drives has grown in the last few decades because of microprocessor and power converter development, with an expectation that 80% of all the produced energy will be used in locomotive traction, electric ship propulsion, more-electric aircraft and renewable energy applications. Although three-phase machines are the common trend, the interest of the research community has recently focused on machines with more than three phases, named multiphase machines, due to their advantages in terms of reliability and postfault usage [ 1 ]. This is the case of safety applications, where the fault-tolerant ability of multiphase drives has attracted the interest of the scientific community. Having more than three phases allows the faulty operation of the drive under specific voltage, current and/or power limits, which makes multiphase drives an interesting solution in critical industry applications, i.e., offshore wind generators, more-electric aircraft and field or traction applications, e.g., the Royal Navy Type-45 destroyer [ 2 ]. Thus, multiphase drives can still be operated without the need for heavy topological changes in the power converter, even if a phase is missing, provided that the number of remaining phases is equal to or greater than three [3–5]. Most of the recent multiphase drive research has been focused on the extension of the control methods usually applied in conventional three-phase drives, along with their enhancement to provide the best performance of the system [ 6 , 7 ]. Compared to classical three-phase drives, multiphase ones reduce the electrical stress in drives and power electronic components, since they can manage more power with lower torque pulsation and current harmonic contents [ 8 ]. In this context, the most common control strategy is the field-oriented control (FOC) technique, based on linear cascaded control Energies 2019,12, 4698; doi:10.3390/en12244698 www.mdpi.com/journal/energies
Energies 2019,12, 4698 2 of 12 loops and assisted by coordinate transformations and modulation stages. The multiphase machine is decomposed into multiple orthogonal d–qsubspaces (fundamental and harmonics components), with each set of d–qvariables being independently controlled. The reference voltages are determined by proportional–integral (PI) controllers, which are inputs for the modulation stage to generate pulse-width-modulation (PWM) switching signals to a power converter, usually a voltage-source converter (VSC). Alternatives to this technique are the ‘direct control’ methods, including direct torque and model-based predictive controllers (DTC and MPC, respectively). They directly switch the VSC state, avoiding the PWM stage and forcing the controlled variables to rapidly track the reference, while achieving normal operation of the drive [1,2,5,8]. Since the healthy operation of the multiphase drive is a significant and complex issue, important and recent research papers also analyze the implications of faulty operation from the control perspective, where FOC, DTC and MPC methods have been studied. It is interesting to note that control techniques based on ‘nonlinear’ controllers (DTC and MPC methods or ‘direct’ controllers) appear as promising control alternatives due to their flexibility and simple formulation, competing with FOC techniques for leading the control solution in the field of multiphase machines and drives [ 5 , 8 ]. The term ‘fault tolerance’ has broad application since the fault can occur in many elements of the system, including VSC and machine faults that lead to short-circuit (i.e., phase [ 9 ], VSC switch [ 10 ], interturn [ 11 ]) or open-circuit (i.e., phase [ 12 ], VSC switch [ 13 ], or line [ 14 ]) faults. This work analyzes the field of multiphase drives and their use in open-phase fault operations, where the recent definition of a reconfiguration-less MPC controller for asymmetrical six-phase drives, based on virtual voltage vectors (VVs) and useful in healthy and faulty operation, seems to be an interesting advance for using direct controllers [ 15 , 16 ]. This work goes beyond [ 15 , 16 ], extending and experimentally validating the idea to different direct controllers and multiphase drives. 2. Basis of Natural Fault-Tolerant Controllers Using MPC The research activity in the application of MPC techniques in the field of multiphase drives has recently given rise to numerous control approaches, the most popular being the finite control set MPC (FCS-MPC) method due to the limited number of possible switching states of the power converter. The most common use is the result of its combination with FOC methods, with the outer speed control loop being maintained while the inner current regulators are substituted by FCS-MPC controllers. This control scheme is depicted in Figure 1, where a distributed-winding five-phase Induction Motor (IM) drive is used as a case example. Energies 2019, 12, x FOR PEER REVIEW 3 of 12 5φ IM VSI i sa i sc i sb i sd i se abcde αβxy ω m θ αβ dq PI * i sq * i sx * i sy ω m * * i sd * i sβ * i sα * i s (k+2) Position Estimator * i sq * i sd JMinimizer min(J) Cost function computation PREDICTIVE MODEL FCS-MPC s i (k+2) p S opt Possible Switching Vectors i s (k) Figure 1. Finite control set model-based predictive control (FCS-MPC) control scheme for a five-phase IM drive fed using a voltage-source inverter (VSI). -1 -0.5 00.5 1 -1 -0.8 -0.6 -0.4 -0.2 0 0.2 0.4 0.6 0.8 1 31 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 α–β 0 βb c d e α a 13 -1 -0.5 00.5 1 -1 -0.8 -0.6 -0.4 -0.2 0 0.2 0.4 0.6 0.8 1 31 1 8 12 2 6 3 7 15 16 20 17 21 24 28 25 22 19 23 27 0 yb c d e x a 14 x–y 4 5 9 13 10 11 29 18 26 30 V0, V31 α β 2 3 4 5 6 7 8 1 9 10 VV1(16,25) VV2(29,24) VV3(8,28) VV4(30,12) VV5(4,14) VV6(15,6) VV7(2,7) VV8(23,3) VV9(1,19) VV10(27,17) Figure 2. Voltage vectors (VVs) in a five-phase IM drive: (upper plots) α–β and x–y subspaces; (lower plot) defined VVs. 3. Extension of the Reconfiguration-less Approach to the DTC Case DTC-based controllers have been also recently proposed and studied in the multiphase drive field for healthy and faulty modes of operation (Figure 3) [18–21]. The basis is to select a stator voltage vector, according to Table 1 and the VV concept, using hysteresis-based controllers for every control period, to obtain reference torque and stator flux tracking. For such purpose, the model of the machine is used to estimate the stator flux and the electromagnetic torque for the DTC controller [22]. In fact, the VVs concept was originally introduced as a way to extend DTC to the multiphase field, maximizing the torque production while minimizing harmonic components in the x–y plane. Hence, the use of VVs in DTC also avoids the problems with full-order closed-loop controllers when openphase faults occur. This work demonstrates that DTC strategies using VVs can also provide the Figure 1. Finite control set model-based predictive control (FCS-MPC) control scheme for a five-phase IM drive fed using a voltage-source inverter (VSI). The fault-tolerant capability of multiphase drives was first studied in [ 17 ], where it was shown that n-phase machines can operate after one or several fault occurrences, as long as the number of
Energies 2019,12, 4698 3 of 12 healthy phases remains greater than or equal to three and at the expense of a reduction in the torque production. The FCS-MPC control system technology finds itself currently at a paradigm-changing tipping point, where emerging applications are under development. In this context, FCS-MPC has proven to be a promising alternative in the fault-tolerance control of the drive, where it was recently shown [ 16 ] that it is possible to skip any control reconfiguration if virtual voltage vectors (VVs) are used. The main idea, shown in Figure 2for our case example, is to substitute the available voltage vectors with new virtual voltage vectors. Large and medium voltage vectors, which are aligned in the α – β plane with opposite directions in the x–yplane, are combined to provide zero average voltage in the x–ysubspace, so harmonic currents in the x–ysubspace are reduced. This has been termed natural fault-tolerance capability, and it has been verified so far by using FCS-MPC strategies and six-phase drives [ 16 ], where the use of VVs introduces an open-loop control of the stator current in the x–yplane, avoiding the main problems of full-order closed-loop controllers when the open-phase fault occurs and the current cannot flow through a damaged phase, e.g., searching for incompatible control goals and voltage vectors that are no longer available. Energies 2019, 12, x FOR PEER REVIEW 3 of 12 5φ IM VSI i sa i sc i sb i sd i se abcde αβxy ω m θ αβ dq PI * i sq * i sx * i sy ω m * * i sd * i sβ * i sα * i s (k+2) Position Estimator * i sq * i sd JMinimizer min(J) Cost function computation PREDICTIVE MODEL FCS-MPC s i (k+2) p S opt Possible Switching Vectors i s (k) Figure 1. Finite control set model-based predictive control (FCS-MPC) control scheme for a five-phase IM drive fed using a voltage-source inverter (VSI). -1 -0.5 00.5 1 -1 -0.8 -0.6 -0.4 -0.2 0 0.2 0.4 0.6 0.8 1 31 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 α–β 0 βb c d e α a 13 -1 -0.5 00.5 1 -1 -0.8 -0.6 -0.4 -0.2 0 0.2 0.4 0.6 0.8 1 31 1 8 12 2 6 3 7 15 16 20 17 21 24 28 25 22 19 23 27 0 yb c d e x a 14 x–y 4 5 9 13 10 11 29 18 26 30 V0, V31 α β 2 3 4 5 6 7 8 1 9 10 VV1(16,25) VV2(29,24) VV3(8,28) VV4(30,12) VV5(4,14) VV6(15,6) VV7(2,7) VV8(23,3) VV9(1,19) VV10(27,17) Figure 2. Voltage vectors (VVs) in a five-phase IM drive: (upper plots) α–β and x–y subspaces; (lower plot) defined VVs. 3. Extension of the Reconfiguration-less Approach to the DTC Case DTC-based controllers have been also recently proposed and studied in the multiphase drive field for healthy and faulty modes of operation (Figure 3) [18–21]. The basis is to select a stator voltage vector, according to Table 1 and the VV concept, using hysteresis-based controllers for every control period, to obtain reference torque and stator flux tracking. For such purpose, the model of the machine is used to estimate the stator flux and the electromagnetic torque for the DTC controller [22]. In fact, the VVs concept was originally introduced as a way to extend DTC to the multiphase field, maximizing the torque production while minimizing harmonic components in the x–y plane. Hence, the use of VVs in DTC also avoids the problems with full-order closed-loop controllers when openphase faults occur. This work demonstrates that DTC strategies using VVs can also provide the Figure 2. Voltage vectors (VVs) in a five-phase IM drive: ( upper plots ) α – β and x–ysubspaces; (lower plot) defined VVs. 3. Extension of the Reconfiguration-less Approach to the DTC Case DTC-based controllers have been also recently proposed and studied in the multiphase drive field for healthy and faulty modes of operation (Figure 3) [ 18 – 21 ]. The basis is to select a stator voltage vector, according to Table 1and the VV concept, using hysteresis-based controllers for every control period, to obtain reference torque and stator flux tracking. For such purpose, the model of the machine is used to estimate the stator flux and the electromagnetic torque for the DTC controller [ 22 ]. In fact, the VVs concept was originally introduced as a way to extend DTC to the multiphase field, maximizing the torque production while minimizing harmonic components in the x–yplane. Hence, the use of VVs in DTC also avoids the problems with full-order closed-loop controllers when open-phase faults occur. This work demonstrates that DTC strategies using VVs can also provide the natural fault-tolerant
Energies 2019,12, 4698 4 of 12 capability, allowing a ripple-free postfault operation with no reconfiguration of the control strategy. Then, opposite to [ 21 ], lookup tables (see Table 1) are not reconstructed after a fault occurrence, and the same control scheme and VVs are used in the pre- and postfault situations. Energies 2019, 12, x FOR PEER REVIEW 4 of 12 natural fault-tolerant capability, allowing a ripple-free postfault operation with no reconfiguration of the control strategy. Then, opposite to [21], lookup tables (see Table 1) are not reconstructed after a fault occurrence, and the same control scheme and VVs are used in the pre- and postfault situations. 5-phase 2-level VSI λ s * ω m i bs i cs i ds i es V dc ω m PI Sector identification T e *dT e dλ s Lookup Table Table I Torque and Flux estimators ω m *+1 -1 0 +1 -1 Flux position λ s ^ 5-PHASE IM Clarke Transformation i αs i xs i βs i ys T e ^ λ s ^ T e ^ ω mth ω m dω m +1 -1 i as Figure 3. Control scheme of a five-phase IM drive using the direct torque controller (DTC) technique. Table 1. Lookup table for the DTC controller in healthy operation. 𝒅𝝀𝒔 𝒅𝑻𝒆 𝒅𝝎𝒎 Position of stator flux (Sector) 1 2 3 4 5 6 7 8 9 10 +1 +1 +1 VV3 VV4 VV5 VV6 VV7 VV8 VV9 VV10 VV1 VV2 −1 VV2 VV3 VV4 VV5 VV6 VV7 VV8 VV9 VV10 VV1 −1 +1 VV9 VV10 VV1 VV2 VV3 VV4 VV5 VV6 VV7 VV8 −1 VV10 VV1 VV2 VV3 VV4 VV5 VV6 VV7 VV8 VV9 0 +1 V0 V31 V0 V31 V0 V31 V0 V31 V0 V31 −1 V0 V31 V0 V31 V0 V31 V0 V31 V0 V31 −1 +1 +1 VV4 VV5 VV6 VV7 VV8 VV9 VV10 VV1 VV2 VV3 −1 VV5 VV6 VV7 VV8 VV9 VV10 VV1 VV2 VV3 VV4 −1 +1 VV8 VV9 VV10 VV1 VV2 VV3 VV4 VV5 VV6 VV7 −1 VV7 VV8 VV9 VV10 VV1 VV2 VV3 VV4 VV5 VV6 0 +1 V31 V0 V31 V0 V31 V0 V31 V0 V31 V0 −1 V31 V0 V31 V0 V31 V0 V31 V0 V31 V0 4. Experimental Work The performance of the DTC controller using VVs was experimentally tested in healthy and open-phase operation, with no reconfiguration of the controller. The experimental test bench is shown in Figure 4. It was composed of a five-phase IM fed by two conventional three-phase VSCs from Semikron. The DC-link was set to 300 V by an external DC power supply. The controller was programmed on a MSK28335 board and a TMS320F28335 microcontroller. The mechanical speed was measured by a digital encoder and the microcontroller’s peripherals. Additionally, a variable load torque was applied by a mechanically coupled DC machine. An open-phase fault condition in phase ‘a’ was emulated in the provided tests by opening a power relay connected in series with the phase. The IM characteristics are listed in Table 2; the reference stator flux was set to 0.389 Wb, the sampling time used was 100 µs and the hysteresis bands of the torque and flux regulators were fixed at 1.06% and 1.29% of the rated values, respectively. Note that a limitation in the integral part of the controller and an anti-windup scheme were included in the implemented control algorithm to prevent integration windup in the PI-based speed controller when the actuator is saturated. Figure 3. Control scheme of a five-phase IM drive using the direct torque controller (DTC) technique. Table 1. Lookup table for the DTC controller in healthy operation. dλsdTedωm Position of Stator Flux (Sector) 12345678910 +1 +1 +1 VV3VV4VV5VV6VV7VV8VV9VV10 VV1VV2 −1 VV2VV3VV4VV5VV6VV7VV8VV9VV10 VV1 −1 +1 VV9VV10 VV1VV2VV3VV4VV5VV6VV7VV8 −1 VV10 VV1VV2VV3VV4VV5VV6VV7VV8VV9 0 +1 V0V31 V0V31 V0V31 V0V31 V0V31 −1 V0V31 V0V31 V0V31 V0V31 V0V31 −1 +1 +1 VV4VV5VV6VV7VV8VV9VV10 VV1VV2VV3 −1 VV5VV6VV7VV8VV9VV10 VV1VV2VV3VV4 −1 +1 VV8VV9VV10 VV1VV2VV3VV4VV5VV6VV7 −1 VV7VV8VV9VV10 VV1VV2VV3VV4VV5VV6 0 +1 V31 V0V31 V0V31 V0V31 V0V31 V0 −1 V31 V0V31 V0V31 V0V31 V0V31 V0 4. Experimental Work The performance of the DTC controller using VVs was experimentally tested in healthy and open-phase operation, with no reconfiguration of the controller. The experimental test bench is shown in Figure 4. It was composed of a five-phase IM fed by two conventional three-phase VSCs from Semikron. The DC-link was set to 300 V by an external DC power supply. The controller was programmed on a MSK28335 board and a TMS320F28335 microcontroller. The mechanical speed was measured by a digital encoder and the microcontroller’s peripherals. Additionally, a variable load torque was applied by a mechanically coupled DC machine. An open-phase fault condition in phase ‘a’ was emulated in the provided tests by opening a power relay connected in series with the phase. The IM characteristics are listed in Table 2; the reference stator flux was set to 0.389 Wb, the sampling time used was 100 µ s and the hysteresis bands of the torque and flux regulators were fixed at 1.06% and
Energies 2019,12, 4698 5 of 12 1.29% of the rated values, respectively. Note that a limitation in the integral part of the controller and an anti-windup scheme were included in the implemented control algorithm to prevent integration windup in the PI-based speed controller when the actuator is saturated. Energies 2019, 12, x FOR PEER REVIEW 5 of 12 abd e c RS232 Serial Ports 5-PHASE IM DRIVE Current Sensors DC MOTOR DRIVE DC MOTOR 5-PHASE IM CONTROL BOARD POWER ELECTRONIC CONVERTERS (VSIs) Switching Signals Phase Currents a b V dc Speed Encoder (ω m ) DC-LINK Figure 4. Experimental system. Table 2. Electrical and mechanical parameters of the five-phase IM. Parameter Value Unit Stator resistance, Rs 12.85 Ω Rotor resistance, Rr 4.80 Ω Stator leakage inductance, Lls 79.93 mH Rotor leakage inductance, Llr 79.93 mH Mutual inductance, Lm 681.7 mH Moment of inertia, J 0.02 kg·m2 Number of pole pairs, p 3 - Rated torque, Tn 4.70 N·m Rated stator flux, λs* 0.389 Wb The transition from prefault to postfault operation was first analyzed when the speed was maintained at 500 rpm and a load torque around 60% of the nominal one was imposed. The results obtained are shown in Figures 5 and 6. Although the speed decreases a little when the fault occurs, it can be observed that the DTC controller is capable of controlling the speed and the torque of the system even using the prefault voltage vectors and system model (see Figures 5a,b). Since the MMF remains the same in both healthy and faulty operation, a circular trajectory is obtained in the α–β currents, as can be seen in Figure 5c. However, a horizontal line appears in the x–y plane because ixs = −iαs and iys = 0. In accordance with the well-known minimum copper loss criterion [23], stator phase currents ‘b’ and ‘e’ are equal in magnitude but present unequal peak values compared to ‘c’ and ‘d’ phase currents, as shown in Figure 6. Figure 4. Experimental system. Table 2. Electrical and mechanical parameters of the five-phase IM. Parameter Value Unit Stator resistance, Rs12.85 Ω Rotor resistance, Rr4.80 Ω Stator leakage inductance, Lls 79.93 mH Rotor leakage inductance, Llr 79.93 mH Mutual inductance, Lm681.7 mH Moment of inertia, J0.02 kg·m2 Number of pole pairs, p3 - Rated torque, Tn4.70 N·m Rated stator flux, λs* 0.389 Wb The transition from prefault to postfault operation was first analyzed when the speed was maintained at 500 rpm and a load torque around 60% of the nominal one was imposed. The results obtained are shown in Figures 5and 6. Although the speed decreases a little when the fault occurs, it can be observed that the DTC controller is capable of controlling the speed and the torque of the system even using the prefault voltage vectors and system model (see Figure 5a,b). Since the MMF remains the same in both healthy and faulty operation, a circular trajectory is obtained in the α – β currents, as can be seen in Figure 5c. However, a horizontal line appears in the x–yplane because i xs = − i αs and i ys =0. In accordance with the well-known minimum copper loss criterion [ 23 ], stator phase currents ‘b’ and ‘e’ are equal in magnitude but present unequal peak values compared to ‘c’ and ‘d’ phase currents, as shown in Figure 6.
Energies 2019,12, 4698 6 of 12 Energies 2019, 12, x FOR PEER REVIEW 6 of 12 Fault ocurrence (a) (b) (c) 00.5 11.5 22.5 3 400 450 500 550 600 Time (s) Speed (rpm) ω m ω * m Fault occurrence ω m ω m * 00.5 11.5 22.5 3 -1 1 3 5 7 Time (s) Torque (N·m) TeTe * T e * T e ^ -3 -1.5 01.5 3 -3 -1.5 0 1.5 3 i α s , i xs (A) i β s , i ys (A) i αβ s i xys i αβs i xys i αs , i xs i βs , i ys Figure 5. Transition from prefault to postfault operation using a DTC controller with VVs. The fault occurs at t = 0.2 s; the speed is set to 500 rpm and a load torque around 60% of the nominal one is applied. (a) Measured speed (𝜔) and its reference (𝜔 ∗); (b) estimated torque (𝑇 ) and its reference (𝑇 ∗); and (c) stator currents in the α–β and x–y planes (𝑖,𝑖 ) Figure 5. Transition from prefault to postfault operation using a DTC controller with VVs. The fault occurs at t=0.2 s; the speed is set to 500 rpm and a load torque around 60% of the nominal one is applied. ( a ) Measured speed ( ωm ) and its reference ( ω∗ m ); ( b ) estimated torque ( ˆ Te ) and its reference (T∗ e); and (c) stator currents in the α–βand x–y planes (iαβs,ixys).
Energies 2019,12, 4698 7 of 12 Energies 2019, 12, x FOR PEER REVIEW 7 of 12 i bs i es i cs i ds Fault instant i as = 0i as = −(i bs + i cs + i ds + i es ) Figure 6. Phase currents 𝑖, 𝑖, 𝑖 and 𝑖 in the transition from prefault to postfault operation using DTC with VVs (the faulty phase, 𝑖, has similar behavior before the fault appears, being null after the fault). The fault occurs at 𝑡=0.2 s, the speed is set to 500 rpm and a load torque around 60% of the nominal one is applied. Next, the dynamic performance of the DTC controller in faulty operation was analyzed. A speed step from 0 to 500 rpm was forced with a null-load torque condition. Figure 7 shows the speed, torque and flux performance (Figure 7a–c), and it can be seen that the DTC scheme provides an accurate tracking performance of all variables. It is necessary to highlight that the electrical torque is limited to 3 N·m, since nominal torque is not reachable in a postfault situation. The phase current evolution is also depicted in Figure 7d. Figure 6. Phase currents ibs , ics , ids and ies in the transition from prefault to postfault operation using DTC with VVs (the faulty phase, ias , has similar behavior before the fault appears, being null after the fault). The fault occurs at t= 0.2 s, the speed is set to 500 rpm and a load torque around 60% of the nominal one is applied. Next, the dynamic performance of the DTC controller in faulty operation was analyzed. A speed step from 0 to 500 rpm was forced with a null-load torque condition. Figure 7shows the speed, torque and flux performance (Figure 7a–c), and it can be seen that the DTC scheme provides an accurate tracking performance of all variables. It is necessary to highlight that the electrical torque is limited to 3 N · m, since nominal torque is not reachable in a postfault situation. The phase current evolution is also depicted in Figure 7d.
Energies 2019,12, 4698 8 of 12 Energies 2019, 12, x FOR PEER REVIEW 8 of 12 -2 0 2 i as (A) -2 0 2 i bs (A) -2 0 2 i cs (A) -2 0 2 i ds (A) 00.5 11.5 22.5 3 -2 0 2 Time (s) i es (A) (a) (b) 00.5 11.5 22.5 3 0 0.2 0.4 0.6 0.8 1 Time (s) Flux (Wb) | λ αβ s || λ αβ s * | (c) 00.5 11.5 22.5 3 0 200 400 600 Time (s) Speed (rpm) ω m ω * m ω m * ω m 00.5 11.5 22.5 3 -2 0 2 4 6 Time (s) Torque (N·m) T e T e * T e * T e ^ (d) Figure 7. Speed step response in open-phase fault operation of the proposed DTC controller. The reference speed is changed from 0 to 500 rpm at 𝑡=0.2 s and no load torque is imposed. (a) Measured speed (𝜔) and its reference (𝜔 ∗); (b) estimated torque (𝑇 ) and its reference (𝑇 ∗); (c) stator flux in the α–β plane; (d) phase currents. Figure 7. Speed step response in open-phase fault operation of the proposed DTC controller. The reference speed is changed from 0 to 500 rpm at t= 0.2 s and no load torque is imposed. ( a ) Measured speed ( ωm ) and its reference ( ω∗ m ); ( b ) estimated torque ( ˆ Te ) and its reference ( T∗ e ); ( c ) stator flux in the α–βplane; (d) phase currents.
Energies 2019,12, 4698 9 of 12 The rejection properties of the system are also studied and the results presented in Figure 8. A change in the load torque is applied at t=0.8 s while the speed reference is fixed to 500 rpm. The tracking performance of the electrical torque is quite accurate, even in the transitory. On the other hand, a decrease in the rotor speed is observed when the fault occurs, but the controller successfully manages the disturbance in a short period of time. Energies 2019, 12, x FOR PEER REVIEW 9 of 12 The rejection properties of the system are also studied and the results presented in Figure 8. A change in the load torque is applied at t = 0.8 s while the speed reference is fixed to 500 rpm. The tracking performance of the electrical torque is quite accurate, even in the transitory. On the other hand, a decrease in the rotor speed is observed when the fault occurs, but the controller successfully manages the disturbance in a short period of time. Finally, a reversal test is reproduced and shown in Figure 9. In this experiment, the reference speed is first settled in at 500 rpm and then changed to −500 rpm at t = 0.2 s. The system is again operated in open-phase fault condition, with a null load torque applied to the system. An appropriate tracking of the speed, the estimated torque and the stator flux is obtained, with a good crossing by zero performance. The evolution of phase currents during this test is depicted in Figure 9d. (a) ( b ) 00.5 11.5 22.5 3 400 450 500 550 600 Time (s) Speed (rpm) ω m ω * m ω m * ω m 00.5 11.5 22.5 3 -2 0 2 4 6 Time (s) Torque (N·m) T e T e * T e * T e ^ Figure 8. Load-torque rejection response in open-phase fault operation of the DTC controller with VVs. A change from 0 N·m to around 60% of the nominal torque is applied at t = 0.8 s. (a) The measured speed (𝜔) and its reference (𝜔 ∗). (b) The estimated torque (𝑇 ) and its reference (𝑇 ∗). Figure 8. Load-torque rejection response in open-phase fault operation of the DTC controller with VVs. A change from 0 N · m to around 60% of the nominal torque is applied at t=0.8 s. ( a ) The measured speed (ωm) and its reference (ω∗ m). (b) The estimated torque ( ˆ Te) and its reference (T∗ e). Finally, a reversal test is reproduced and shown in Figure 9. In this experiment, the reference speed is first settled in at 500 rpm and then changed to − 500 rpm at t=0.2 s. The system is again operated in open-phase fault condition, with a null load torque applied to the system. An appropriate tracking of the speed, the estimated torque and the stator flux is obtained, with a good crossing by zero performance. The evolution of phase currents during this test is depicted in Figure 9d.