scieee AI-readable full text Open interactive document viewer

TVOCs and PM 2.5 in Naturally Ventilated Homes: Three Case Studies in a Mild Climate

Fernández-Agüera, Jessica; Domínguez Amarillo, Samuel; Fornaciari, Marco; Orlandi, Fabio

Abstract

In southern Europe, the present stock of social housing is ventilated naturally, with practice varying in the di erent seasons of the year. In winter, windows are kept closed most of the day with the exception of short periods for ventilation, whereas the rest of the year the windows are almost permanently open. In cold weather, air changes depend primarily on the air infiltrating across the envelope and when the temperature is warm, on the air flowing in through open windows. CO2, PM2.5, and TVOC concentration patterns were gathered over a year’s time in three social housing developments in southern Europe with di erent airtightness conditions and analyzed to determine possible relationships between environmental parameters and occupants’ use profiles. Correlations were found between TVOC and CO2 concentrations, for human activity was identified as the primary source of indoor contaminants: peak TVOC concentrations were related to specific household activities such as cooking or leisure. Indoor and outdoor PM2.5 concentrations were likewise observed to be correlated, although not linearly due to the presence of indoor sources. Ventilation as presently practiced in winter appears to be insufficient to dilute indoor contaminants in all three buildings, nor does summertime behavior guarantee air quality.

Full text

sustainability Article TVOCs and PM 2.5 in Naturally Ventilated Homes: Three Case Studies in a Mild Climate Jesica Fernández-Agüera 1, Samuel Dominguez-Amarillo 1,* , Marco Fornaciari 2and Fabio Orlandi 2 1Instituto Universitario de Arquitectura y Ciencias de la Construcción, Escuela Técnica Superior de Arquitectura, Universidad de Sevilla, 41004 Seville, Spain; [email protected] 2Dipartimento di Ingegneria Civile ed Ambientale, Universitàdegli Studi di Perugia, 06123 Perugia, Italy; [email protected] (M.F.); [email protected] (F.O.) *Correspondence: [email protected] Received: 19 September 2019; Accepted: 30 October 2019; Published: 7 November 2019   Abstract: In southern Europe, the present stock of social housing is ventilated naturally, with practice varying in the different seasons of the year. In winter, windows are kept closed most of the day with the exception of short periods for ventilation, whereas the rest of the year the windows are almost permanently open. In cold weather, air changes depend primarily on the air infiltrating across the envelope and when the temperature is warm, on the air flowing in through open windows. CO 2 , PM 2.5 , and TVOC concentration patterns were gathered over a year’s time in three social housing developments in southern Europe with different airtightness conditions and analyzed to determine possible relationships between environmental parameters and occupants’ use profiles. Correlations were found between TVOC and CO 2 concentrations, for human activity was identified as the primary source of indoor contaminants: peak TVOC concentrations were related to specific household activities such as cooking or leisure. Indoor and outdoor PM 2.5 concentrations were likewise observed to be correlated, although not linearly due to the presence of indoor sources. Ventilation as presently practiced in winter appears to be insufficient to dilute indoor contaminants in all three buildings, nor does summertime behavior guarantee air quality. Keywords: indoor air quality; social housing; TVOCs concentration; CO 2 concentration; PM2.5 concentration 1. Introduction Different national regulations have established a legally binding target of 80% reduction in carbon emissions for 2050 in response to the European regulations. This will require a major effort from countries in southern Europe and the Mediterranean arc to improve a social and ageing housing-stock, mostly obsolescent, whose performance is far from these objectives [ 1 ], as may be the case in Spain. Effective and optimized energy intervention and retrofitting techniques must be developed in order to achieve adequate performance of the indoor environments assuring energy conservation. Within the strategies to achieve the objectives emitted from the Energy Performance of Buildings Directive (EPBD), envelope airtightness and fabric insulation can be considered the key factors with the greatest impact on thermal performance, energy consumption, and indoor air quality in homes [2,3]. These considerations are applicable to a significant portion of Europe: all of the Mediterranean area, from southern Portugal to Turkey. Overall, at the European level, most dwellings are detached, but in southern countries, collective dwelling types [ 4 ] predominate, especially when it comes to social housing and the general housing stock [ 5 , 6 ]. Although regional variations are common, the architecture and construction of multi-family buildings present strong similarities throughout the Sustainability 2019,11, 6225; doi:10.3390/su11226225 www.mdpi.com/journal/sustainability Sustainability 2019,11, 6225 2 of 22 area [7], differing widely from the usual solutions in central and northern European countries. Many of these architectural solutions are a legacy of the 1960s and 1970s residential construction boom [ 8 , 9 ]. The residents of the area not only share a similar climate, but also similar architectural approaches and social and cultural habits in terms of the use and occupation of housing [ 10 ], an aspect of capital importance when analyzing the actual performance of the stock. Although both definitions and programs for social housing vary between different countries, broadly this can be understood as housing developments which have received some type of public financial support. Social housing shares a series of characteristics, such as being occupied by lower income population and usually being built to minimum construction quality standards [11]. As a rule, the area building stock has been conceived as naturally ventilated on the understanding that the climate is benign, and generally lacks built-in heating or air conditioning systems. These buildings generally lacked mechanically controlled ventilation systems until the implementation of the EPBD transpositions [ 12 ]. Ventilation was based on extraction through bathrooms and kitchens—by means of the stack effect across static vents. This approach is often ineffective due to prevailing weather conditions. Indoor air quality relies on the uncontrolled inflow of air through the building envelope (infiltration) or voluntary ventilation (manual operation of windows) with unequal results. The widespread use of reinforced concrete structures, a feature of social housing in Mediterranean cities, together with internal division systems, results in very tight internal compartmentalization in housing, with infiltration concentrated on facades and air leakage [ 13 – 15 ]. These facades are usually cavity walls built with brick or block fabric (medium to heavy weight) and a plastered interior. The environmental quality of social housing is strongly affected by the need to maintain the heat and energy of the indoor environment, primarily during the winter months. In general, these homes suffer from poor thermal comfort, especially during cold periods [ 16 – 18 ]. However, this situation is not only confined to southern Europe, but is also identified in other colder climates where one would expect a greater climate adaptation of the housing conditions [ 19 ]. This situation can be attributed to a widespread lack of heating systems and energy poverty issues affecting these social groups [ 1 ], and results in the dwellings being kept closed for most hours during winter. The pollutants of the building environment are the result of the interaction between several sources of pollution: inadequate construction materials or technical defects; furniture; occupants and the activities they carry out; moisture, dust or dirt presence; the use of chemical products (disinfectants, cleaning products); tobacco smoke, etc. [ 20 – 22 ]. It is also necessary to consider the pollution coming in from outdoors (pollen, dust, spores, industrial pollutants, biodiesel) [ 23 , 24 ]. This has an important influence on indoor air quality, as well as on the design of the ventilation and thermal-conditioning system. An extensive review of the evidence found in the literature has been collected in [25]. Study [ 26 ] in naturally ventilated homes shows that building structures are linked to a range of health hazards, including indoor air pollution, noise, airborne infectious diseases, and mould contamination. Of the different pollutants, Particulate Matter (PM) and Volatile Organic Compounds (VOCs) are the most commonly found in homes. PM can be generated endogenously or exogenously in housing. PM2.5 has been associated with increased respiratory and cardiovascular morbidity [27]. Total indoor volatile organic compounds are generated by household products in residences, followed by combustion processes and environmental tobacco smoke, deodorizers, and off-gassing of building materials [ 28 ]. These chemicals can cause irritation to eyes or nose, dizziness, nausea, headaches, and allergic reactions, and some of them are carcinogenic [ 29 ]. Deng et al. [ 30 ] showed that exposure to new furniture and home redecoration during pregnancy significantly increased childhood asthma. In Europe, it is worth noting studies from the UK, Denmark, Macedonia, and Slovakia which research the indoor air quality in family homes. In the UK, McGill [ 19 , 31 , 32 ] investigated the differences in indoor air quality between mechanical and naturally ventilated homes, including Passivhaus dwellings. In Macedonia, the recommended value for human exposure to TVOCs was exceeded in 32% of houses; and mean concentrations of PM2.5 from 16.80 µg/m3to 30.70 µg/m3were established [33]. Sustainability 2019,11, 6225 3 of 22 In Slovakia, thirty-five households were selected to investigate indoor environmental quality. Concentrations of TVOCs were significantly higher in the apartments than in the family houses. The average TVOC levels in the apartments and family houses were 519.7 µ g/m 3 and 330.2 µ g/m 3 , respectively. Higher TVOC levels were also observed in homes where it is not a common practice to open windows during cleaning activities [34]. More studies related CO 2 with indoor air quality [ 35 – 37 ]. For example, in Spain, thermal comfort and CO 2 (as indoor air quality index) in residential buildings with different degrees of airtightness was studied in two climates [ 38 ]. Similar studies in school buildings show there was a higher level of symptomatology, or level of discomfort perceived by the occupants, when the windows were open [ 39 ]. However, the emphasis on energy saving and the improvement of indoor thermal conditions has led many of these homes to undergo envelope repairs and energy retrofits, either individually or at whole-building level. The elimination of air draughts and the pursuit of energy conservation have led to many of these interventions focusing on improving air sealing of enclosures, thus reducing the exchanges of air with the exterior. In addition, increasing numbers of products composed of synthetic materials, plastics, compressed wood products, glues, and varnishes, etc., are now being introduced into buildings. Indoor renewal actions with new flooring, paint, and other materials are modifying the constructive materiality of the original design of these dwellings [ 26 , 27 ]. This situation raises concerns regarding the possibility of a negative impact on the healthiness of the interior spaces traditionally associated with housing in colder parts of Europe [ 28 – 30 ], although it may also be affecting the mild areas after renovations [18,31]. The mild climate of the area, usually temperate but with hot summers, contributes to the development of a specific mixed natural ventilation mode, with a window-opening pattern that is very different from the rest of central and northern Europe. In winter, the dwellings remain closed most of the day. However, during mild seasons, the windows—or some windows at least—are almost continuously open, and this is also frequent during the summer—except during high temperatures—as different studies have previously established [ 17 , 32 ]. This scenario plays a vital role in the pollution-situation of the indoor atmosphere, with a more direct relationship between both environments, stronger than that found in colder areas. Although the possibility of finding higher levels of pollutants [ 40 , 41 ] in more airtight dwellings is generally recognized, there are insufficient data—both qualitative and quantitative—about this behavior in the homes of southern Europe. These homes present different modes of ventilation (warm /cold period) and are generally perceived as very open dwellings [ 42 – 45 ]. A notable aspect is the potential relationship between different environmental parameters and species in contributing more detailed information for predictive tools. While the introduction of mechanical ventilation in homes has been developed following current national regulatory standards (CTE 2006) [ 46 ], the building stock analyzed was built prior to the implementation of the EPBD directives and represents more than half of existing homes. These dwellings are usually ventilated through infiltration and window operation. The possibility of incorporating mechanical ventilation into this housing stock is very limited due to physical and morphological restrictions, especially given the predominance of social housing in these regions. This paper aims to analyze the indoor air quality (CO 2 , TVOC, and PM 2.5 ) in three representative case studies in Andalusia, in order to establish whether there is a correlation between indoor air quality and different parameters or occupant behavior. 2. Materials and Methods 2.1. Context and Location Seville is a city in the south of Spain with the largest housing stock, of which more than one third can be classified as social type and over half was built before 1979 [ 9 ]. The population of the city is about 700,000, although considering the floating population, and the metropolitan area this figure Sustainability 2019,11, 6225 4 of 22 exceeds 1,500,000 inhabitants [ 47 ], hence its special representativeness and impact. Located at latitude 37 ◦ 25 ´ N and at a height of 26 meters, this city [ 48 ] has a temperate climate with an annual average temperature of 18.6 ◦ C. Although, in general, the winters are mild with minimum average temperatures of 5 ◦ C, the cold period may generate discomfort and inadequate indoor conditions —even temperature related health-issues— in low-standard housing [ 49 ]. Summers are hot and dry with peak temperatures reached from May to September, usually with broad daily thermal oscillation [ 50 ]. The midseason is long, with many hours of mild temperatures throughout the year. This climatic context promotes the use of natural ventilation and the half-open dwelling state for a considerable number of hours per year. This situation makes the area significant as a model for behavior analysis in the building stock, sharing many characteristics with other urban areas in the south of Europe. The traffic levels in the city can be considered high although they do not reach the levels of traffic of large European cities. 2.2. Sampling The buildings studied were selected after a lengthy process designed to suitably represent the building stock. The first phase identified and characterized 250 social housing developments built within the city limits in the period studied (1940–1979). This totalled 99,437 of an expected total of 100,510 units: in other words 98.93% of the entire population, which for all practical purposes can be regarded as the whole. The procedure for identifying and classifying these units is described in [6]. Subsequent analysis led to grouping the developments into particularly representative types characterized by the features found in each sub-period. A second grouping (covering 83 developments and 46,476 units, or 47% of the population) established the essential morpho-constructional features of these developments, identifying subject types by sub-period and building a matrix of typical characteristics also by sub-period, all of which are described in [ 9 ]. Inductive analysis was used to define the population parameters by intervals. Temperature, humidity, and Carbon dioxide (CO 2 ) level measurements were analyzed for 16 social housing units [ 18 ]. In addition, air tightness tests were conducted on the units [ 13 , 15 ] and relationships between this parameter and CO 2 concentration were analyzed in this study. A review of the state of the art of this topic suggested that additional parameters such as PM 2.5 and VOC should be studied to determine whether indoor CO 2 concentration could be used as an indicator of indoor air quality, as shown in other studies. Due to the limited availability of measuring equipment, of the 16 units monitored for CO 2 , three dwellings representative of different degrees of airtightness and different user behavior were chosen for the study. It represents 3 very common dwelling types in the area —representing extreme and average values airtightness and representative of the social housing stock. They were monitored under normal operative conditions (Table 1). 2.3. Data Collection Data were collected from July 2017 to June 2018. Daily data were recorded at 10-minute intervals. Instrumentation and methods were monitored following the ISO7726:2002 specifications [ 51 ]. This monitoring was conducted in occupied flats. Data were recorded using three sensor sets per unit: one located in the living-room (day zone) and two in the bedroom (night zone) (Figure 1). The CO 2 loggers were calibrated by the research group, and the TVOC and PM logger were factory calibrated and provided sufficient accuracy [ 52 ]. A Wöhler CDL 210 datalogger recorded the air temperature and relative humidity with an accuracy of 0.5 ◦ C and 3%, respectively, and measured CO 2 over a range of 0–9000 ppm, with an accuracy of 50 ppm ± 5%. A Foobot datalogger recorded the PM 2.5 and TVOC with an accuracy of 4 µg/m3and 5 %, respectively. Data were downloaded every month in situ. As indoor CO 2 concentration, temperature, and Relative Humidity (RH) are never the same throughout a room [ 53 ], the sensor was positioned to detect a mean value, i.e., in the area where occupants would be breathing. That is, between 1 and 1.5 meters high on the living room, and on the bedside table on bedrooms. Sustainability 2019,11, 6225 5 of 22 Table 1. Features of the homes in the study sample. Case Study CS1 CS2 CS3 Year of construction 1965 1978 1993 N◦inhabitants 2 2 4 Floor area (m2)49 75 73 Indoor volume (m3)113 178 191 Height 2.3 2.37 2.62 Windows gross area (m2)13 19 15 Heating system Electric heater (portable) Electric heater (portable) Ducted XD Heat pump (whole house unit) Cooling system Split XD unit in bedroom Split XD unit in living-room Ducted XD Heat pump (whole house unit) Ventilation system Natural ventilation operable windows Natural ventilation operable windows Natural ventilation operable windows n50 (h−1)9.5 14 15.5 Smokers No No No Gas stove Yes No No Carpets No No No DHW boiler (indoor) No No Yes Urban location Urban square, middle town Secondary streets Boulevard, outskirt area Floor 3 4 4 Facades exposed to the wind 2 2 2 Occupied schedule 00–10 h(miao) and (miao)17–24 h 00–07 h (miao)and (miao)19–24 h 00 –24 h Sustainability 2019, 10, x FOR PEER REVIEW 6 of 24 Figure 1. Location of the sensor sets in each dwelling. TVOC and PM2.5 (red) and CO2, air temperature and humidity (blue). Height: 0.8 m. 2.4. Threshold Level The limit values, tolerance margins, and warning thresholds for concentrations in ambient air are intended to provide guidance on how to reduce the effects of air pollution on health. 2.4.1. CO2 Concentration Although the main source of emission for carbon dioxide (CO2) is usually the building occupants, it should be noted that open combustion elements such as gas stoves and Domestic hot water (DHW) heaters — and their combustion gases — are often found within these dwellings. Many indoor air quality (IAQ) studies adopt CO2 concentration as an indicator of actual ventilation rates and as IAQ-index. It is generally accepted that CO2 keeps 'bad company' and that levels above 1000 ppm are indicative of poor ventilation rates [54]—which corresponds to a ventilation rate of 8 l/s per person. This standard continues to be relevant, with a threshold referenced in many national and international guidelines [55], which will be the reference value adopted in this work. Even though carbon dioxide is not normally considered an indoor air pollutant, some adverse health effects have been associated with room levels above 5000 ppm due to the displacement of oxygen in the air [56]. 2.4.2. PM2.5 Concentration Airborne particulates are solid or liquid substances suspended in the air flow, and can include dust, fumes, smoke, microorganisms, mist, and fog [57]. These particles can range widely in diameter, the most harmful in domestic environment are respirable suspended particulates (RSPs), especially the fine inhalable particle fraction, 2.5 µm or smaller—PM2.5 [58–61]. The figures used as the control limit for the analysis proposed will be based on those established by the World Health Organization (WHO) [62], which proposes an annual limit of the concentration of PM2.5 of 10 µg/m3 and a daily limit of 25 µg/m3. Reference values inside dwellings were documented by Gotschi [63], with the lowest concentration (9.5 µg/m3) measured in Finland, and the highest (50 µg/m3) in Italy. 2.4.3. TVOCs Concentration Together, with the aforementioned, the most common fraction of pollutants within homes is the volatile carbon compound family (VOCs). While there may be thousands of chemicals within this group, almost 900 of them have been identified in the indoor environment, mainly linked to indoor furnishings, finishes, and other building elements such as paint, solvents, adhesives, carpets, fabrics, and textiles. Exposure to elevated airborne concentrations of VOCs can lead to a range of toxicological effects, including fatigue, headaches, drowsiness, and eye irritation among many others [64], both in the short and long term [65]. However, the wide variety of potential sources and compositions renders it impractical to measure the concentrations of each chemical individually. Accordingly, the concept of total volatile organic compound (TVOC) attempts to address this practical limitation by Figure 1. Location of the sensor sets in each dwelling. TVOC and PM 2.5 (red) and CO 2 , air temperature and humidity (blue). Height: 0.8 m. Outdoor conditions (outdoor dry air temperature, relative humidity, dew point, wind, and others) were provided by the Spanish National Meteorological Office (AEMET), while the conditions of outdoor PM 2.5 distribution and TVOC were obtained from the Consejer í a de Medio Ambiente y Ordenaci ó n del Territorio of the Regional Andalusian Government. Periodic contrast measures were taken using portable reference sensors to ensure consistent and accurate measurements. 2.4. Threshold Level The limit values, tolerance margins, and warning thresholds for concentrations in ambient air are intended to provide guidance on how to reduce the effects of air pollution on health. 2.4.1. CO2Concentration Although the main source of emission for carbon dioxide (CO 2 ) is usually the building occupants, it should be noted that open combustion elements such as gas stoves and Domestic hot water (DHW) heaters — and their combustion gases — are often found within these dwellings. Many indoor air quality (IAQ) studies adopt CO 2 concentration as an indicator of actual ventilation rates and as IAQ-index. It is generally accepted that CO 2 keeps ‘bad company’ and that levels above 1000 ppm are indicative of poor ventilation rates [ 54 ]—which corresponds to a ventilation rate of 8 l/s per person. Sustainability 2019,11, 6225 6 of 22 This standard continues to be relevant, with a threshold referenced in many national and international guidelines [ 55 ], which will be the reference value adopted in this work. Even though carbon dioxide is not normally considered an indoor air pollutant, some adverse health effects have been associated with room levels above 5000 ppm due to the displacement of oxygen in the air [56]. 2.4.2. PM2.5 Concentration Airborne particulates are solid or liquid substances suspended in the air flow, and can include dust, fumes, smoke, microorganisms, mist, and fog [ 57 ]. These particles can range widely in diameter, the most harmful in domestic environment are respirable suspended particulates (RSPs), especially the fine inhalable particle fraction, 2.5 µ m or smaller—PM 2.5 [ 58 – 61 ]. The figures used as the control limit for the analysis proposed will be based on those established by the World Health Organization (WHO) [ 62 ], which proposes an annual limit of the concentration of PM 2.5 of 10 µ g/m 3 and a daily limit of 25 µ g/m 3 . Reference values inside dwellings were documented by Gotschi [ 63 ], with the lowest concentration (9.5 µg/m3) measured in Finland, and the highest (50 µg/m3) in Italy. 2.4.3. TVOCs Concentration Together, with the aforementioned, the most common fraction of pollutants within homes is the volatile carbon compound family (VOCs). While there may be thousands of chemicals within this group, almost 900 of them have been identified in the indoor environment, mainly linked to indoor furnishings, finishes, and other building elements such as paint, solvents, adhesives, carpets, fabrics, and textiles. Exposure to elevated airborne concentrations of VOCs can lead to a range of toxicological effects, including fatigue, headaches, drowsiness, and eye irritation among many others [ 64 ], both in the short and long term [ 65 ]. However, the wide variety of potential sources and compositions renders it impractical to measure the concentrations of each chemical individually. Accordingly, the concept of total volatile organic compound (TVOC) attempts to address this practical limitation by providing a simple measurement for the aggregate of all volatile organic compounds without making distinctions between individual chemicals. Typically, the concentrations of VOC detected indoors are higher than outdoors and have increased over the past decade, so that outdoor contribution may be considered negligible most of the time. Although there is no common regulation on the admissible TVOCs exposure inside homes, it is possible to establish some general thresholds from which inhabitants’ sensitivity may arise (physiological responses and pathological processes can be identified in occupants). In the range of 120 to 1200 ppb, symptoms of irritation and discomfort can begin to appear in some occupants. Up to 10,000 ppb, these symptoms are generalized, taking different forms depending on the degree of sensitivity of the inhabitants and the species present, developing toxicity levels of up to 10,000 ppb [ 66 ]. A maximum level of 120 ppb is usually recommended for the indoor environment to be considered healthy [ 67 ]. We have considered this figure a desirable target and figures up to 1200 ppb as a potential-risk indoor environment. These considerations require a general approach and are highly sensitive to the types of VOC compound present, some of which will be very harmful in very low concentrations. 3. Results 3.1. CO2 In all three cases, CO 2 concentrations have shown wide fluctuations over time. Winter concentrations oscillate between minimums around 400 ppm (barely equivalent to outdoor concentration) and maximums above 2000 ppm. There are some peaks above 4500 ppm in the living rooms and concentrations above 3000 ppm, with peaks above 7500 ppm, in the bedrooms. Typical value (median) for daytime living rooms ranged between 853 ppm (CS1) and 882 ppm (CS2), while for bedrooms this varied between 1199 (CS2) and 2385 ppm (CS1), mostly at night (Figure 2). Sustainability 2019,11, 6225 7 of 22 Sustainability 2019, 10, x FOR PEER REVIEW 7 of 24 providing a simple measurement for the aggregate of all volatile organic compounds without making distinctions between individual chemicals. Typically, the concentrations of VOC detected indoors are higher than outdoors and have increased over the past decade, so that outdoor contribution may be considered negligible most of the time. Although there is no common regulation on the admissible TVOCs exposure inside homes, it is possible to establish some general thresholds from which inhabitants’ sensitivity may arise (physiological responses and pathological processes can be identified in occupants). In the range of 120 to 1200 ppb, symptoms of irritation and discomfort can begin to appear in some occupants. Up to 10,000 ppb, these symptoms are generalized, taking different forms depending on the degree of sensitivity of the inhabitants and the species present, developing toxicity levels of up to 10,000 ppb [66]. A maximum level of 120 ppb is usually recommended for the indoor environment to be considered healthy [67]. We have considered this figure a desirable target and figures up to 1200 ppb as a potential-risk indoor environment. These considerations require a general approach and are highly sensitive to the types of VOC compound present, some of which will be very harmful in very low concentrations. 3. Results 3.1.CO 2 In all three cases, CO 2 concentrations have shown wide fluctuations over time. Winter concentrations oscillate between minimums around 400 ppm (barely equivalent to outdoor concentration) and maximums above 2000 ppm. There are some peaks above 4500 ppm in the living rooms and concentrations above 3000 ppm, with peaks above 7500 ppm, in the bedrooms. Typical value (median) for daytime living rooms ranged between 853 ppm (CS1) and 882 ppm (CS2), while for bedrooms this varied between 1199 (CS2) and 2385 ppm (CS1), mostly at night (Figure 2). Figure 2. Daily CO 2 concentration average for an annual period. Figure 2. Daily CO2concentration average for an annual period. CO 2 concentration in winter usually exceeds WHO recommendations—a limit value of 1000 ppm for healthy environments [ 68 ]—indicating low ventilation rates and a potential risk of air-quality related issues. This aspect is of great significance in bedrooms with conditions below the threshold no more than 50% of the time, (which really corresponds to unoccupied daytime). Even living rooms usually have high figures for several hours (lower values for CS1 may be attributed to low use intensity due to work schedules). There is a clear relationship between infiltration and CO 2 concentration values, stronger in bedrooms at night. The least airtight dwelling (CS3) remains below 1000 ppm more often (for a similar emission source of two people during sleep time) than the two more airtight dwellings. In mild season conditions, the frequent operation of windows in a semi-open situation for extended periods allows CO 2 concentration to fall below 1000 ppm in living rooms most of the time, between 95% and 99% of the hours. Although the values in the bedrooms are much lower than in winter, they present a wider distribution. Users often close windows at night, increasing CO 2 concentrations, with 10% to 20% of the hours over the 1000 ppm line (Figure 3). Sustainability 2019, 10, x FOR PEER REVIEW 8 of 24 Figure 3. Percentage of hours that CO2 concentration is below the threshold in winter. CO2 concentration in winter usually exceeds WHO recommendations—a limit value of 1000 ppm for healthy environments [68]—indicating low ventilation rates and a potential risk of airquality related issues. This aspect is of great significance in bedrooms with conditions below the threshold no more than 50% of the time, (which really corresponds to unoccupied daytime). Even living rooms usually have high figures for several hours (lower values for CS1 may be attributed to low use intensity due to work schedules). There is a clear relationship between infiltration and CO2 concentration values, stronger in bedrooms at night. The least airtight dwelling (CS3) remains below 1000 ppm more often (for a similar emission source of two people during sleep time) than the two more airtight dwellings. In mild season conditions, the frequent operation of windows in a semi-open situation for extended periods allows CO2 concentration to fall below 1000 ppm in living rooms most of the time, between 95% and 99% of the hours. Although the values in the bedrooms are much lower than in winter, they present a wider distribution. Users often close windows at night, increasing CO2 concentrations, with 10% to 20% of the hours over the 1000 ppm line (Figure 3). There is a clear indoor state shift between the cold season and the intermediate one in terms of quality if carbon dioxide is assumed as IAQ indicator. This is clearly related to the evolution from closed environment to the semi-open model. 0 10 20 30 40 50 60 70 80 90 100 400 1000 1600 >1600 % of hours CO2concentration (ppm) Living-room ( CS1) Living-room ( CS2) Living-room ( CS3) Bedroom (CS1) Bedroom (CS2) Bedroom (CS3) Figure 3. Percentage of hours that CO2concentration is below the threshold in winter. There is a clear indoor state shift between the cold season and the intermediate one in terms of quality if carbon dioxide is assumed as IAQ indicator. This is clearly related to the evolution from closed environment to the semi-open model. Sustainability 2019,11, 6225 8 of 22 Hours of occupancy in bedrooms and living rooms and the number of occupants in each, along with reported ventilation times, are shown in Figure 4. CO 2 concentration by time of day is also presented in the figure in order to determine whether users’ replies to the surveys were consistent with CO2analysis. Sustainability 2019, 10, x FOR PEER REVIEW 9 of 24 Figure 4. Hourly CO 2 concentration and number of occupants in bedrooms and living room in summer and winter for all case studies. Hours of occupancy in bedrooms and living rooms and the number of occupants in each, along with reported ventilation times, are shown in Figure 4. CO 2 concentration by time of day is also presented in the figure in order to determine whether users’ replies to the surveys were consistent with CO 2 analysis. Figure 4. Hourly CO 2 concentration and number of occupants in bedrooms and living room in summer and winter for all case studies. Sustainability 2019,11, 6225 9 of 22 Hours of occupancy and number of occupants reported varied widely. In winter, Seville dwellings were ventilated for 10 to 30 min in the morning. In contrast, in summer, windows remained open all night in CS2 and CS3. In CS2, the number of occupants tended to be small, as the users were not usually present at the same time. This dwelling also had the lowest CO2concentration. 3.2. Particle Concentration (PM2.5) During measurement, PM 2.5 indoor concentrations present a wide oscillation without a clear pattern. Annual average values are 16.09 µ g/m 3 (CS1), 7.1 µ g/m 3 (CS2), and 9.66 µ g/m 3 (CS3). CS1 exceeds the annual limit for the concentration of PM 2.5 of 10 µ g/m 3 . Although dwelling CS1 presents strong peaks, it is not representative of the average internal situation. The dwelling ambient reaches values as high as 1402 µ g/m 3 although normal values usually remain below 50 µ g/m 3 (95th percentile representation). Even so, these values are high in relation to the recommendations of the WHO [ 68 ] and the European Environmental Agency (EEA) [ 69 ]. During winter, the less airtight dwelling tends to have higher median PM 2.5 concentrations (95th percentile =25.14 µ g/m 3 ) (Table 2). Users exceed the PM2.5 threshold of 10 µg/m3between 45% and 15% of the hours (Figure 5). Table 2. PM2.5 concentration in the three case studies. CS1 CS2 CS3 Annual Average (µg/m3)16.09 7.10 9.66 Median (µg/m3)8.76 4.40 8.60 Standard deviation 53.85 13.20 6.84 Range (µg/m3)0÷1402 0÷367 0÷283 Mild season Average (µg/m3)14.83 7.30 11.17 Median (µg/m3)8.40 4.50 9.80 Standard deviation 46.99 12.40 7.41 Range (µg/m3)0÷1396 0÷367 0÷283 Winter Average (µg/m3)13.5 6.4 9.4 Median (µg/m3)7.6 4.3 9.1 Standard deviation 52.7 11.2 7.3 Range (µg/m3)0÷1402 0÷324 0÷103 Summer Average (µg/m3)25.47 5.34 7.62 Median (µg/m3)22.10 3.26 6.76 Standard deviation 22.19 9.72 5.04 Range (µg/m3)10÷1200 0÷298 0÷99 In all three cases, the PM 2.5 daily average reference value is not exceeded, except for peak episodes of particles of indoor origin in dwelling CS1 during the winter. However, the usual values are relatively high (Table 3). Table 3. PM2.5 daily concentration average. Mild Season Winter Day Exterior (µg/m3) CS1 (µg/m3) CS2 (µg/m3) CS3 (µg/m3) Exterior (µg/m3) CS1 (µg/m3) CS2 (µg/m3) CS3 (µg/m3) Monday 35.4 17.6 9.6 12.6 27.2 21.1 5.6 11.5 Tuesday 53.2 17.9 3.6 14.2 40.8 6.7 4.3 10.6 Wednesday 38.7 16.1 0.2 20.7 15.1 5.3 1.2 10.4 Thursday 45.0 11.9 0.6 15.6 25.5 6.3 1.6 10.7 Friday 29.0 17.8 4.0 8.5 26.9 9.3 3.7 13.8 Saturday 10.9 6.0 2.1 11.8 27.2 88.3 3.1 13.5 Sunday 15.0 13.0 3.4 12.3 18.8 49.8 2.4 11.3 Weekly 32.5 14.3 3.4 13.7 25.9 26.7 3.1 11.7 Sustainability 2019,11, 6225 16 of 22 highlighted by the correlations between indoor related parameters (CO 2 , VOC, and RH) and the outdoor evolution of temperature. The most obvious case is the positive correlation (0.50) between CO 2 indoor-concentration and the outdoor–indoor temperature difference ( ∆ T), similar to outdoor air-temperature (–0.46), which is negative in this case. These relationships would be highlighted if unoccupied periods were excluded (Figure 13). Sustainability 2019, 10, x FOR PEER REVIEW 19 of 25 (a) (b) Figure 13. TVOC and CO2 concentration evolution in a week in January in CS1 (a) and CS2 (b). In the mild season, the relationship between indoor/outdoor environments is strengthened and becomes clearly dependent (outdoor > indoor) (Table 6). This can be seen in the downward shift of the concentration pattern of indoor-origin pollutants due to a greater ventilation-driven dilution, and also to the indoor mirroring of outdoor thermal oscillations. Humidity and air temperature evolution couple with outside conditions with little to no thermal decrease and time lag due to the high air interchange rate. However, indoor species show specific dynamics with slight correlations between the parameters relating to the pollutants. This does not apply to RH and indoor-air temperature, which are mostly collinear. However, interior species characterized by very specific dynamics differ greatly and are much more unique than those in winter. Only weak correlations are found between indoor physical parameters and pollutant concentration. It should be noted that despite the expected colinearity between PM 2.5iIND -PM 2.5OUT , this is somewhat weak (0.37) and slightly distorted, indicating the presence of different mechanisms of particle distribution and indoor-capture, including those relating to indoor emissions (internal sources of particle emission) and those linked to infiltration through the envelope and surface absorption of particulate matter in the indoor environment. Figure 13. TVOC and CO2concentration evolution in a week in January in CS1 (a) and CS2 (b). Indoor parameters show a significant cross-relationship between humidity and VOCs, which may be associated to indoor home activity. The weaker CO 2 dependency shows a closer link to specific task emissions, especially those related to activities in the kitchen and bathroom, than to normal inhabitant presence. Cold season, even in mild climate areas, shows indoor environments isolated from the exterior much of the time, with no linear link to the outdoor air quality daily evolution beyond external temperature inverse ventilation rate dependency leading to worse indoor air-quality parameters. The stronger probabilistic parameter is external temperature, with a clear inverse dependency with natural ventilation. Natural ventilation rate shows a clear inverse-dependency to outdoor temperature and thus indoor air quality indicators (Table 5). Sustainability 2019,11, 6225 17 of 22 Table 5. Correlation matrix in dwellings in the low ventilation period (cold season). CO2IND PM2.5IND VOCIND HRIND TIND TOUT ∆T CO2IND 0.04 0.48 0.2 0.18 −0.46 0.5 PM2.5IND 0.04 0.2 0.18 0.13 −0.05 0.07 VOCIND 0.48 0.2 0.68 −0.02 −0.33 0.33 HRIND 0.2 0.18 0.68 −0.09 −0.59 0.59 TIND 0.18 0.13 −0.02 -0.09 0.23 −0.06 TOUT −0.46 −0.05 −0.33 −0.59 0.23 −0.99 ∆T 0.5 0.07 0.33 0.59 −0.06 −0.99 In the mild season, the relationship between indoor/outdoor environments is strengthened and becomes clearly dependent (outdoor >indoor) (Table 6). This can be seen in the downward shift of the concentration pattern of indoor-origin pollutants due to a greater ventilation-driven dilution, and also to the indoor mirroring of outdoor thermal oscillations. Humidity and air temperature evolution couple with outside conditions with little to no thermal decrease and time lag due to the high air interchange rate. However, indoor species show specific dynamics with slight correlations between the parameters relating to the pollutants. This does not apply to RH and indoor-air temperature, which are mostly collinear. However, interior species characterized by very specific dynamics differ greatly and are much more unique than those in winter. Only weak correlations are found between indoor physical parameters and pollutant concentration. Table 6. Correlation matrix in dwellings in ventilation period (mild season). PM2.5IND VOCIND TIND HRIND PM2.5OUT PM2.5IND 0.11 −0.06 0.41 0.37 VOCIND 0.11 0.2 −0.08 0.18 TIND −0.06 0.2 −0.38 0.11 HRIND 0.41 −0.08 −0.38 0.26 PM2.5OUT 0.37 0.18 0.11 0.26 It should be noted that despite the expected colinearity between PM 2.5iIND -PM 2.5OUT , this is somewhat weak (0.37) and slightly distorted, indicating the presence of different mechanisms of particle distribution and indoor-capture, including those relating to indoor emissions (internal sources of particle emission) and those linked to infiltration through the envelope and surface absorption of particulate matter in the indoor environment. While some of the peak episodes can be understood as unique, they represent potential stages within households where high figures are often present due to internal activity. These cases can be understood as beacons of current trends, identifying a transition to an indoor-source scenario. This trend has also been identified in the literature, linked to the increasing use of furniture made of synthetic materials, as well as to the growing tendency to use chemicals at home for both cleaning and personal care [55–59]. 5. Conclusions The parameters that define IAQ in the indoor environment in the dwellings under survey show figures far from those generally accepted as healthy for most of the year. This situation results in the overall excessive exposure of home inhabitants. However, these figures vary greatly, due mainly to the variable occupancy pattern in the dwelling and the relationship with window opening response. Indoor CO 2 concentrations clearly correlate with airtightness but typically exceed the 1000 ppm limit recommended by the WHO for healthy environments in all cases. Indoor particle (PM 2.5 ) levels are highly variable. This parameter is strongly related to outdoor conditions, so no regular pattern can be established. Indoor levels are relatively high when dwellings are in a half-open situation in the mild season and periods in which the windows usually remain Sustainability 2019,11, 6225 18 of 22 open due to weather and urban environment conditions. During cold periods, the less airtight flats usually present the highest PM 2.5 particle concentration figures. Otherwise, the most airtight properties usually show higher TVOC concentrations, although this parameter is highly distorted by the irregular patterns of indoor-source emission rates linked to indoor activities. In winter, most of the time, these usually remain below the recommended threshold of 1200 ppb, when the effects of TVOCs are usually noticed. However, peak episodes above these limits are not unusual in the homes analyzed, but they remain under the toxicity threshold of 10,000 ppb. Although these homes cannot be considered actual healthy environments in long-term exposure, they do not reach potentially hazardous short-term exposure situations, except for short time-frames. The building interface system (envelope and windows) of these dwellings is no longer able to guarantee adequate indoor environments for a significant number of hours per year, even in locations traditionally identified as lightly-polluted environments, such as those of southern Spain. The current approach for housing energy retrofitting relies heavily on the addition of insulation layers to the fabric, new airtight windows, and air-seal enhancement of joints. The current ability of dwelling stock to incorporate mechanical ventilation and thermal appliances into these dwellings, as promoted by some strategies such as Passivhaus, is very limited and is restricted by factors such as interval height or lack of technical spaces. Consequently, the disruption of the air-interchange dynamics resulting from increasing air-tightness and supported by the progressive change in lifestyle can become a growing risk-factor for inhabitants’ health, even in regions where traditionally the opening of windows has been fully established. A final question arises: Do current energy conservation approaches lead to scenarios where the health of the indoor environment is put at risk? As has been emphasized, current air-exchange rates must be increased for a better indoor dilution and removal of pollutants, something which is difficult to achieve in the absence of mechanical ventilation systems. This also contradicts the usual techniques of improving the energy conservation approach, mainly based on increasing thermal resistance and airtightness, as these measures become less effective as a significant portion of the total energy transfer is linked to the interchange of air masses. Therefore, there is a need for further research and discussion to identify the appropriate rates of air-exchange for contemporary stock-dwellings and how these could be made compatible with energy saving needs. Whole-house mechanical ventilation, such as that required by ASHRAE Standard 62.2, has proven to be an effective strategy for some contaminants. In keeping with this assumption, higher levels of ventilation air have been shown to reduce concentrations of many VOCs. However, this measure is difficult to follow in the housing stock in need of retrofitting. Despite the difficulty, it would be advisable for further research to focus on identifying good practice in ventilation and the optimization of envelope airtightness. This would serve as a basic step for the development of specific guides, with the potential for specialization by building type and features [ 75 – 77 ]. These could provide tailored ventilation protocols and calendars which would allow users to modify their current customs, which are often counterproductive to maintaining good conditions. In addition, it would also make it possible to work on airtightness to ensure optimum conditions are obtained, especially when working on retrofits. This would prevent instances of insufficient ventilation in spaces, as long as no mechanical ventilation systems were installed. However, the implementation of this measure as a widespread solution is unlikely at present. Finally, this would also allow the development of information systems, via APPs or personal devices, to adapt ventilation needs and their integration with new control domotics systems and If This Then That (IFTTT )protocols for instance. Author Contributions: Conceptualization, J.F.-A. and S.D.-A.; Data curation, J.F.-A. and S.D.-A.; Formal analysis, J.F.-A., S.D.-A., M.F.and F.O.; Investigation, J.F.-A. and S.D.-A.; Methodology, J.F.-A., S.D.-A., M.F.and F.O.; Supervision, J.F.-A.; Writing–original draft, J.F.-A., S.D.-A., M.F.and F.O.; Writing–review & editing, J.F.-A., S.D.-A., M.F.and F.O. Funding: This research received no external funding. Sustainability 2019,11, 6225 19 of 22 Acknowledgments: The wind velocity and outdoor temperature data were furnished by Spain’s National Meteorology Agency (AEMET), and outdoor PM 2.5 distribution and TVOC ´ s by the Consejeria de Medio Ambiente y Ordenaci ó n del Territorio of the Regional Andalusian Government. The authors wish to thank to Dipartimento di Ingegneria Civile ed Ambientale, Universit à degli Studi di Perugia for their welcome in the authors research stay. Conflicts of Interest: The authors declare no conflict of interest. References 1. Sendra, J.J.; Dom í nguez-Amarillo, S.; Bustamante, P.; Le ó n, A.L. Energy intervention in the residential sector in the south of spain: Current challenges. Inf. Constr. 2013,65, 457–464. [CrossRef] 2. Fern á ndez-Agüera, J.; Sendra Salas, J.J.; Su á rez Medina, R.; Dom í nguez-Amarillo, S. Airtightness and Indoor Air Quality in Subsidised Housing in Spain. In Proceedings of the 36th AIVC Conference, Madrid, Spain, 23–24 September 2015. 3. Dom í nguez, S.; Sendra, J.J.; Le ó n, A.L.; Esquivias, P.M. Towards Energy Demand Reduction in Social Housing Buildings: Envelope System Optimization Strategies. Energies 2012,5, 2263–2287. [CrossRef] 4. Eurostat. Living Conditions in Europe; European Union: Luxembourg, 2014; p. 1. 5. Pennestr ì , D. The energy and Enviromental requalification of post-war housing: Problematics and innovative solutions for the building envelope. In Central Europe Towards Sustainable Buildings 2013: Sustainable Refurbishment of Existing Building Stock; CESB13: Prague, the Czech Republic, 2013; pp. 1–7. Available online: http://www.cesb.cz/cesb13/proceedings/1_refurbishment/CESB13_1243.pdf (accessed on 7 November 2019). 6. Dom í nguez-Amarillo, S.; Sendra, J.J.; Fern á ndez-Agüera, J.; Escand ó n, R. La Construcci ó n de la Vivienda Social en Sevilla y su Catalogación 1939–1979; Universidad de Sevilla: Sevilla, Spain, 2017. 7. Ferrari, S.; Zanotto, V. Building Energy Performance Assessment in Southern Europe; Springer: Milano, Italy, 2015. 8. Matteis, D. Affordable Housing Praxis for Urban Sustainability; Ipertesto. Europen Programme for Urban Sustainable Development: Verona, Italy, 2008. 9. Dom í nguez-Amarillo, S.; Sendra, J.J.; Oteiza San Jos é , I. La Envolvente T é rmica de la Vivienda Social: El Caso de SEVILLA, 1939 a 1979 Title, 1st ed.; Editorial Consejo Superior de Investigaciones Cient í ficas: Madrid, Spain, 2016. 10. Allen, J.; Barlow, J.; Leal, J.; Maloutas, T.; Padovani, L. Housing and Welfare in Southern Europe; Blackwell Publishing Ltd: Hoboken, NJ, USA, 2008. 11. BPIE. Europe’s Buildings under the Microscope; European Union: Bruxelles, Belgium, 2011. 12. C ó digo T é cnico de la Edificaci ó n (CTE); Real Decreto 314/2006 de 17 de marzo: Madrid, Spain, 2006; Volume BOE 74 Ministerio de vivienda, pp. 1816–11831. 13. Fern á ndez-Agüera, J.; Dom í nguez-Amarillo, S.; Sendra, J.J.; Su á rez, R. An approach to modelling envelope airtightness in multi-family social housing in Mediterranean Europe based on the situation in Spain. Energy Build. 2016,128, 236–253. [CrossRef] 14. Fern á ndez-Agüera, J.; Sendra, J.J.; Dom í nguez, S.; Dom í nguez-Amarillo, S. Protocols for measuring the airtightness of multi-dwelling units in Southern Europe. Procedia Eng. 2011,21, 98–105. [CrossRef] 15. Fern á ndez-Agüera, J.; Dom í nguez-Amarillo, S.; Sendra, J.J.; Su á rez, R.; Oteiza, I. Social housing airtightness in Southern Europe. Energy Build. 2019,183, 377–391. [CrossRef] 16. Santamouris, M.; Kolokotsa, D.; Santamouris, M. On the impact of urban overheating and extreme climatic conditions on housing, energy, comfort and environmental quality of vulnerable population in Europe. Energy Build. 2015,98, 125–133. [CrossRef] 17. Giancola, E.; Soutullo, S.; Olmedo, R.; Heras, M.; Celemin, M.D.R. Evaluating rehabilitation of the social housing envelope: Experimental assessment of thermal indoor improvements during actual operating conditions in dry hot climate, a case study. Energy Build. 2014,75, 264–271. [CrossRef] 18. Dom í nguez-Amarillo, S.; Fern á ndez-Agüera, J.; Sendra, J.J.; Roaf, S. Rethinking User Behaviour Comfort Patterns in the South of Spain—What Users Really Do. Sustainability 2018,10, 4448. [CrossRef] 19. McGill, G.; Oyedele, L.O.; McAllister, K. Case study investigation of indoor air quality in mechanically ventilated and naturally ventilated UK social housing. Int. J. Sustain. Built Environ. 2015 ,4, 58–77. [CrossRef] 20. European Commission. Risk Assessment on Inddor Air Quality; Eurpean Union: Brussels, Belgium, 2007. Sustainability 2019,11, 6225 20 of 22 21. Begum, B.A.; Hopke, P.K. Identification of Sources from Chemical Characterization of Fine Particulate Matter and Assessment of Ambient Air Quality in Dhaka Bangladesh. Aerosol Air Qual. Res. 2018 ,19, 118–128. [CrossRef] 22. Koz á kov á c, J.; Leoni, C.; Kl á n, M.; Hovorka, J.; Racek, M.; Kostejn, M.; Ondr á ˇcek, J.; Moravec, P.; Schwarz, J. Chemical Characterization of PM1-2.5 and its Associations with PM1, PM2.5-10 and Meteorology in Urban and Suburban Environments. Aerosol Air Qual. Res. 2018,18, 1684–1697. [CrossRef] 23. Vormittag, E.M.; Rodrigues, C.G.; De Andr é , P.A.; Saldiva, P.H.N. Assessment and Valuation of Public Health Impacts from Gradual Biodiesel Implementation in the Transport Energy Matrix in Brazil. Aerosol Air Qual. Res. 2018,18, 2375–2382. [CrossRef] 24. Sarigiannis, D.A.; Kermenidou, M.; Nikolaki, S.; Zikopoulos, D.; Karakitsios, S.P. Mortality and Morbidity Attributed to Aerosol and Gaseous Emissions from Biomass Use for Space Heating. Aerosol Air Qual. Res. 2015,15, 2496–2507. [CrossRef] 25. Patino, E.D.L.; Siegel, J.A. Indoor environmental quality in social housing: A literature review. Build. Environ. 2018,131, 231–241. [CrossRef] 26. Vardoulakis, S.; Dimitroulopoulou, C.; Thornes, J.; Lai, K.-M.; Taylor, J.; Myers, I.; Heaviside, C.; Mavrogianni, A.; Shrubsole, C.; Chalabi, Z.; et al. Impact of climate change on the domestic indoor environment and associated health risks in the UK. Environ. Int. 2015,85, 299–313. [CrossRef] [PubMed] 27. Arvanitis, A.; Kotzias, D.; Kephalopoulos, S.; Carrer, P.; Cavallo, D.; Cesaroni, G.; De Brouwere, K.; de Oliveira-Fernandes, E.; Forastiere, F.; Fossati, S.; et al. The INDEX-PM project: Health risks from exposure to indoor particulate matter. Fresenius Environ. Bull. 2010,9, 2458–2471. 28. Bari, M.A.; Kindzierski, W.B.; Wheeler, A.J.; H é roux, M.-E.; Wallace, L.A. Source apportionment of indoor and outdoor volatile organic compounds at homes in Edmonton, Canada. Build. Environ. 2015 ,90, 114–124. [CrossRef] 29. Jones, A.P. Indoor air quality and health. Atmos. Environ. 1999,33, 4535–4564. [CrossRef] 30. Deng, Q.; Lu, C.; Ou, C.; Liu, W. Effects of early life exposure to outdoor air pollution and indoor renovation on childhood asthma in China. Build. Environ. 2015,93, 84–91. [CrossRef] 31. McGill, G.; Qin, M.; Oyedele, L. A case study investigation of indoor air quality in UK Passivhaus dwellings. Energy Procedia 2014,62, 190–199. [CrossRef] 32. McGill, G.; Oyedele, L.O.; McAllister, K.; Qin, M. Effective indoor air quality for energy-efficient homes: A comparison of UK rating systems. Archit. Sci. Rev. 2016,59, 159–173. [CrossRef] 33. Vilˇcekov á , S.; Apostoloski, I.; Meˇciarov á , L’.; Burdov á , E.; Kisel’ á k, J. Investigation of Indoor Air Quality in Houses of Macedonia. Int. J. Environ. Res. Public Health 2017,14, 37. [CrossRef] [PubMed] 34. Meˇciarov á , L’; Vilˇcekov á , S.; Burdov á , E.K.; Kisel á k, J. Factors Effecting the Total Volatile Organic Compound (TVOC) Concentrations in Slovak Households. Int. J. Environ. Res. Public Health 2017,14, 1443. 35. Satish, U.; Mendell, M.J.; Shekhar, K.; Hotchi, T.; Sullivan, D.; Streufert, S.; Fisk, W.J. Is CO 2 an indoor pollutant? Direct effects of low-to-moderate CO 2 concentrations on human decision-making performance. Environ. Health Perspect. 2012,120, 1671–1677. [CrossRef] [PubMed] 36. Hesaraki, A.; Myhren, J.A.; Holmberg, S. Influence of different ventilation levels on indoor air quality and energy savings: A case study of a single-family house. Sustain. Cities Soc. 2015,19, 165–172. [CrossRef] 37. Derbez, M.; Berthineau, B.; Cochet, V.; Lethrosne, M.; Pignon, C.; Ribéron, J.; Kirchner, S. Indoor air quality and comfort in seven newly built, energy-efficient houses in France. Build. Environ. 2014 ,72, 173–187. [CrossRef] 38. Fern á ndez-Agüera, J.; Dom í nguez-Amarillo, S.; Alonso, C.; Mart í n-Consuegra, F.; Dom í nguez, S. Thermal comfort and indoor air quality in low-income housing in Spain: The influence of airtightness and occupant behaviour. Energy Build. 2019,199, 102–114. [CrossRef] 39. Fern á ndez-Agüera, J.; Campano, M. Á .; Dom í nguez-Amarillo, S.; Acosta, I.; Sendra, J.J. CO 2 Concentration and Occupants’ Symptoms in Naturally Ventilated Schools in Mediterranean Climate. Buildings 2019 ,9, 197. 40. Missia, D.A.; Demetriou, E.; Michael, N.; Tolis, E.; Bartzis, J. Indoor exposure from building materials: A field study. Atmos. Environ. 2010,44, 4388–4395. [CrossRef] 41. Rosch, C.; Kohajda, T.; Röder, S.; Von Bergen, M.; Schlink, U. Relationship between sources and patterns of VOCs in indoor air. Atmos. Pollut. Res. 2014,5, 129–137. [CrossRef] Sustainability 2019,11, 6225 21 of 22 42. Sharpe, T.; Farren, P.; Howieson, S.; Tuohy, P.G.; McQuillan, J. Occupant interactions and effectiveness of natural ventilation strategies in contemporary new housing in Scotland, UK. Int. J. Environ. Res. Public Health 2015,12, 8480–8497. [CrossRef] [PubMed] 43. Langer, S.; Bekö, G. Indoor air quality in the Swedish housing stock and its dependence on building characteristics. Build. Environ. 2013,69, 44–54. [CrossRef] 44. D’Ambrosio Alfano, F.R.; Dell’Isola, M.; Ficco, G.; Palella, B.I.; Riccio, G. Experimental air-tightness analysis in mediterranean buildings after windows retrofit. Sustainability 2016,8, 991. [CrossRef] 45. Imessad, K.; Derradji, L.; Mokhtari, F.; Chenak, A.; Kharchi, R.; Messaoudene, N.A. Impact of passive cooling techniques on energy demand for residential buildings in a Mediterranean climate. Renew. Energy 2014 ,71, 589–597. [CrossRef] 46. De Vivienda, M. Real Decreto 314/2006, de 17 de Marzo, por el que se Aprueba el C ó digo T é cnico de la Edificaci ó n; BOE-A-2006-5515; Gobierno de España, España, 2006; Available online: https://www.boe.es/buscar/doc.php? id=BOE-A-2006-5515 (accessed on 7 November 2019). 47. Instituto Nacional de Estadistica. Encuesta Continua de Hogares Año 2017; INE: Madrid, Spain, 2017. 48. Rubel, F.; Kottek, M. Observed and projected climate shifts 1901-2100 depicted by world maps of the Köppen-Geiger climate classification. Meteorol. Z. 2010,19, 135–141. [CrossRef] 49. Vasconcelos, J.; Freire, E.; Morais, J.; Machado, J.; Santana, P. The health impacts of poor housing conditions and thermal discomfort. Procedia Environ. Sci. 2011,4, 158–164. [CrossRef] 50. AEMET. Gu í a Resumida del Clima en España (1981–2010); Agencia Estatal de Meteorolog í a: Madrid, Spain, 2012. 51. UNE-EN ISO 7726:2002. Ergonom í a de los Ambientes T é rmicos. Instrumentos de Medida de las Magnitudes F í sicas; Asociación Española de Normalización–ISO: Madrid, Spain, 2002. 52. Sousan, S.; Koehler, K.; Hallett, L.; Thomas, P. Evaluation of consumer monitors to measure particulate matter. J. Aerosol Sci. 2017,107, 123–133. [CrossRef] 53. Seppanen, O.A.; Fisk, W.J.; Mendell, M.J. Association of ventilation rates and CO 2 concentrations with health and other responses in commercial and institutional buildings. Indoor Air 1999,9, 226–252. [CrossRef] 54. Porteus, C.D. Sensing a historic low CO 2 future. In Chemistry, Emission Control, Radioactive Pollution and Indoor Air Quality; Books on Demand: Norderstedt, Germany, 2011. 55. CEN EN Standrad 15251. Indoor Environment Input Parameters for Design and Assessment of Energy Performance of Buildings; New CEN standard: EN: Madrid, Spain, 2007. 56. Witorsch, P.; Spagnolo, S.V. Air Pollution and Lung Disease in Adults; CRC Press: Boca Raton, FL, USA, 1994. 57. Karagulian, F.; Belis, C.A.; Dora, C.F.C.; Prüss-Ustün, A.M.; Bonjour, S.; Adair-Rohani, H.; Amann, M. Contributions to cities’ ambient particulate matter (PM): A systematic review of local source contributions at global level. Atmos. Environ. 2015,120, 475–483. [CrossRef] 58. ISO. ISO 23210: Stationary Source Emissions—Determination of PM10/PM2,5 Mass Concentration in Flue Gas—Measurement at Low Concentrations by Use of Impactors; International Organization for Standardization: Geneva, Switzerland, 2009. 59. Henschel, S.; Chan, G.; World Health Organization. Health Risks of Air Pollution in Europe—HRAPIE Project New Emerging Risks to Health from Air Pollution—Results from the Survey of Experts; World Heath Organization (WHO): Geneva, Switzerland, 2013. 60. Katsouyanni, K. Ambient air pollution and health. Br. Med. Bull. 2003,68, 143–156. [CrossRef] 61. Autrup, H. Ambient air pollution and adverse health effects. Procedia Soc. Behav. Sci. 2010 ,2, 7333–7338. [CrossRef] 62. OMS. Gu í as de Calidad del aire de la OMS Relativas al Material Particulado, el Ozono, el Di ó xido de Nitr ó geno y el Di ó xido de Azufre. Actualizaci ó n Mundial 2005; Organizaci ó n Mundial de la Salud: Geneva, Switzerland, 2005; p. 25. 63. Gotschi, T.; Oglesby, L.; Mathys, P.; Monn, C.; Manalis, N.; Koistinen, K.; Jantunen, M.; Hanninen, O.; Polanska, L.; Kunzli, N. Comparison of black smoke and PM2.5 levels in indoor and outdoor environments of four European cities. Environ. Sci. Technol. 2002,36, 1191–1197. [CrossRef] [PubMed] 64. European Collaborative Action. Sampling Strategies for Volatile Organic Compounds in Indoor Air; Publications Office of the European Union: Brussels, Belgium, 1995. 65. Larsen, L. Environmental Health Sourcebook; Omnigraphics: Detroit, MI, USA, 2010. 66. Fujiwara, D. Indoor Air Quality Assessment; Ontoario Association of Architects: Toronto, ON, Canada, 2014. Sustainability 2019,11, 6225 22 of 22 67. U.S. EPA. Exposure Factors Handbook 2011 Edition (Final Report); EPA/600/R-09/052F; U.S. Environmental Protection Agency: Washington, DC, USA, 2011. 68. Penney, D.; Benignus, V.; Kephalopoulos, S.; Kotzias, D.; Kleinman, M.; Verrier, A. Guidelines for Indoor Air Quality; National Institutes for Healt: Bethesda, MD, USA, 2010. 69. EEA. Air Quality in EUROPE—2016 Report; European Environment Agency: København, Denmark, 2016. 70. Mart í n-Olmedo, P.; S á nchez-Villegas, P.; Daponte, A. Improving Knowledge and Communication for Decision Making on Air Pollution and Health in Europe: Local City Report Seville; Public Health Agency of Barcelona: Barcelona, Spain, 2008. 71. Alonso, E.F.; Mart í nez, T.R.; Cambra, K.C.; Lopez, L.C.; Boldo, E.P.; Zorrilla, B.T.; Daponte, A.C.; Aguilera, I.J.; Toro, S.C.; Iñiguez, C.H.; et al. Health impact evaluation of particle air pollution in five Spanish cities. European APHEIS project. Rev. Esp. Salud Publica 2005,79, 297–308. 72. Tan, C.C.; Finney, K.N.; Chen, Q.; Russell, N.V.; Sharifi, V.N.; Swithenbank, J. Experimental investigation of indoor air pollutants in residential buildings. Indoor Built Environ. 2013,22, 471–489. [CrossRef] 73. Gens, A.; Hurley, J.F.; Tuomisto, J.T.; Friedrich, R. Health impacts due to personal exposure to fine particles caused by insulation of residential buildings in Europe. Atmos. Environ. 2014,84, 213–221. [CrossRef] 74. Asikainen, A.; Carrer, P.; Kephalopoulos, S.; Fernandes, E.D.O.; Wargocki, P.; Hanninen, O. Reducing burden of disease from residential indoor air exposures in Europe (HEALTHVENT project). Environ. Health 2016 ,15, S35. [CrossRef] 75. Fern á ndez-Agüera, J.; Dom í nguez-Amarillo, S.; Sendra, J.J.; Suarez, R. Predictive models for airtightness in social housing in a Mediterranean region. Sustain. Cities Soc. 2019,51, 101695. [CrossRef] 76. Norton, T.; Grant, J.; Fallon, R.; Sun, D.-W. Optimising the ventilation configuration of naturally ventilated livestock buildings for improved indoor environmental homogeneity. Build. Environ. 2010 ,45, 983–995. [CrossRef] 77. Prignon, M.; Van Moeseke, G. Factors influencing airtightness and airtightness predictive models: A literature review. Energy Build. 2017,146, 87–97. [CrossRef] © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).