scieee AI-readable full text Open interactive document viewer

β-decay half-lives and β-delayed neutron emission probabilities for several isotopes of Au, Hg, Tl, Pb, and Bi, beyond N = 126

Caballero Folch, R.; Domingo Pardo, César; Agramunt-Ros, J.; Algora, A.; Ameil, F.; Ayyad, Y.; Guerrero Sánchez, Carlos

Abstract

Background: There have been measurements on roughly 230 nuclei that are β-delayed neutron emitters. They range from 8 He up to 150La. Apart from 210Tl, with a branching ratio of only 0.007%, no other neutron emitter has been measured beyond A = 150. Therefore, new data are needed, particularly in the region of heavy nuclei around N = 126, in order to guide theoretical models and help understand the formation of the third r-process peak at A ∼ 195. Purpose: To measure both β-decay half-lives and neutron branching ratios of several neutron-rich Au, Hg, Tl, Pb, and Bi isotopes beyond N = 126. Method: Ions of interest were produced by fragmentation of a 238U beam, selected and identified via the GSI-FRS fragment separator. A stack of segmented silicon detectors (SIMBA) was used to measure ion implants and β decays. An array of 30 3 He tubes embedded in a polyethylene matrix (BELEN) was used to detect neutrons with high efficiency and selectivity. A self-triggered digital system is employed to acquire data and to enable time correlations. The latter were analyzed with an analytical model and results for the half-lives and neutron-branching ratios were derived by using the binned maximum-likelihood method. Results: Twenty new β-decay half-lives are reported for 204−206Au, 208–211Hg, 211–216Tl, 215–218Pb, and 218–220Bi, nine of them for the first time. Neutron emission probabilities are reported for 210,211Hg and 211–216Tl. Conclusions: The new β-decay half-lives are in good agreement with previous measurements on nuclei in this region. The measured neutron emission probabilities are comparable to or smaller than values predicted by global models such as relativistic Hartree Bogoliubov plus the relativistic quasi-particle random phase approximation (RHB + RQRPA).

Full text

PHYSICAL REVIEW C 95, 064322 (2017) β-decay half-lives and β-delayed neutron emission probabilities for several isotopes of Au, Hg, Tl, Pb, and Bi, beyond N=126 R. Caballero-Folch,1,2,*C. Domingo-Pardo,3J. Agramunt,3A. Algora,3,4F. Ameil,5Y. Ayyad,6J. Benlliure,6M. Bowry,7 F. Calviño,1D. Cano-Ott,8G. Cortès,1T. Davinson,9I. Dillmann,2,5,10 A. Estrade,5,11 A. Evdokimov,5,10 T. Faestermann,12 F. Farinon,5D. Galaviz,13 A. R. García,8H. Geissel,5,10 W. Gelletly,7R. Gernhäuser,12 M. B. Gómez-Hornillos,1 C. Guerrero,14,15 M. Heil,5C. Hinke,12 R. Knöbel,5I. Kojouharov,5J. Kurcewicz,5N. Kurz,5Yu. A. Litvinov,5L. Maier,12 J. Marganiec,16 M. Marta,5,10 T. Martínez,8F. Montes,17,18 I. Mukha,5D. R. Napoli,19 C. Nociforo,5C. Paradela,6S. Pietri,5 Zs. Podolyák,7A. Prochazka,5S. Rice,7A. Riego,1B. Rubio,3H. Schaffner,5Ch. Scheidenberger,5,10 K. Smith,5,17,18,20,21 E. Sokol,22 K. Steiger,12 B. Sun,5J. L. Taín,3M. Takechi,5D. Testov,22,23 H. Weick,5E. Wilson,7J. S. Winfield,5R. Wood,7 P. J. Woods,9and A. Yeremin22 1INTE, DFEN - Universitat Politècnica de Catalunya, E-08028 Barcelona, Spain 2TRIUMF, Vancouver, British Columbia V6T 2A3, Canada 3IFIC, CSIC - Universitat de València, E-46071 València, Spain 4Institute of Nuclear Research of the Hungarian Academy of Sciences, Debrecen H-4001, Hungary 5GSI Helmholtzzentrum für Schwerionenforschung GmbH, D-64291 Darmstadt, Germany 6Universidade de Santiago de Compostela, E-15782 Santiago de Compostela, Spain 7Department of Physics, University of Surrey, Guildford GU2 7XH, United Kingdom 8CIEMAT, E-28040 Madrid, Spain 9University of Edinburgh, Edinburgh EH9 3JZ, United Kingdom 10Justus-Liebig-Universität Giessen, D-35392 Giessen, Germany 11St. Mary’s University, Halifax, Nova Scotia B3H 3C3, Canada 12Physik Department E12, Technische Universität München, D-85748 Garching, Germany 13Centro de Física Nuclear da Universidade de Lisboa, 169-003 Lisboa, Portugal 14CERN Physics Department, CH-1211 Geneve, Switzerland 15Universidad de Sevilla, E-41080 Sevilla, Spain 16ExtreMe Mater Institute, D-64291 Darmstadt, Germany 17NSCL, Michigan State University, East Lansing, Michigan 48824, USA 18Joint Institute for Nuclear Astrophysics, Notre Dame, Indiana 46615, USA 19Instituto Nazionale di Fisica Nucleare, Laboratori Nazionale di Legnaro, I-35020 Legnaro, Italy 20University of Notre Dame, South Bend, Indiana 46556, USA 21University of Tennessee, Knoxville, Tennessee 37996, USA 22Flerov Laboratory, Joint Institute for Nuclear Research, 141980 Dubna, Russia 23Institute de Physique Nucléaire d’Orsay, F-91405 Orsay, France (Received 19 January 2017; published 23 June 2017) Background: There have been measurements on roughly 230 nuclei that are β-delayed neutron emitters. They range from 8He up to 150La. Apart from 210Tl, with a branching ratio of only 0.007%, no other neutron emitter has been measured beyond A=150. Therefore, new data are needed, particularly in the region of heavy nuclei around N=126, in order to guide theoretical models and help understand the formation of the third r-process peak at A∼195. Purpose: To measure both β-decay half-lives and neutron branching ratios of several neutron-rich Au, Hg, Tl, Pb, and Bi isotopes beyond N=126. Method: Ions of interest were produced by fragmentation of a 238U beam, selected and identified via the GSI-FRS fragment separator. A stack of segmented silicon detectors (SIMBA) was used to measure ion implants and β decays. An array of 30 3He tubes embedded in a polyethylene matrix (BELEN) was used to detect neutrons with high efficiency and selectivity. A self-triggered digital system is employed to acquire data and to enable time correlations. The latter were analyzed with an analytical model and results for the half-lives and neutron-branching ratios were derived by using the binned maximum-likelihood method. Results: Twenty new β-decay half-lives are reported for 204−206Au, 208–211Hg,211–216Tl,215–218Pb, and 218–220Bi, nine of them for the first time. Neutron emission probabilities are reported for 210,211Hg and 211–216Tl. *[email protected]; [email protected] Published by the American Physical Society under the terms of the Creative Commons Attribution 4.0 International license. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI. 2469-9985/2017/95(6)/064322(16) 064322-1 Published by the American Physical Society R. CABALLERO-FOLCH et al. PHYSICAL REVIEW C 95, 064322 (2017) Conclusions: The new β-decay half-lives are in good agreement with previous measurements on nuclei in this region. The measured neutron emission probabilities are comparable to or smaller than values predicted by global models such as relativistic Hartree Bogoliubov plus the relativistic quasi-particle random phase approximation (RHB +RQRPA). DOI: 10.1103/PhysRevC.95.064322 I. INTRODUCTION Very-neutron-rich nuclei may emit one or more neutrons when they disintegrate via βdecay. This is the so-called βdelayed neutron (βn) emission process, which is energetically allowed when the Qβvalue of the decay exceeds the neutron separation energy Snof the daughter nucleus. The βnemission hasbeenexperimentallydetermined for about 230 neutron-rich nuclei, spanning from 8He up to 150La [1–4]. Most of these measurementstook advantageofthelarge fission yields around the two fission peaks at A∼95 and A∼138 in thermal neutron-induced fission. However, β-delayed neutron emission has remained essentially inaccessible for nuclei heavier than A=150, where only a minuscule value of 0.007% has been reported for the βn-emission probability of 210Tl [5,6]. Because of the scarce or nonexistent βndata in the heavy-mass region, rapid neutron capture r-process [7] calculations have to rely entirely on theoretical models [8–10]. However, the performance of such models for reproducing the features of the βdecay in r-process waiting-point nuclei has been tested with experimental data only for the two shell closures at N=50 and N=82 from measurements such as those reported in Refs. [11–17]. The comparison is much more limited in the N=126 region, where only half-lives in the neighborhood of the doubly magic 208Pb were available (see, e.g., Ref. [18]). The neutron-rich nuclei “south” of 208Pb are difficult to study experimentally because of the very small production cross sections and the large background induced by the heavy primary beam. In the present work it was possible to produce and identify reliably secondary neutron-rich nuclei in the region “south-east” of 208Pb in the chart of nuclides thanks to the high-energy (1 GeV/u) 238U beams available at the GSI facility.Extendedmotivationand results for this experimentwere recently published in Ref. [19]. Here we present more details on the experimental apparatus in Sec. II, the analysis methodology and results, which are reported in Sec. III and, finally, Secs. IV and Vsummarize the main results and conclusions. II. EXPERIMENTAL SETUP AND ION IDENTIFICATION The present measurements were carried out at the GSI Helmholtz Center for Heavy Ion Research. A 238U beam was accelerated to an energy of 1 GeV/ubytheUNILAC linear accelerator coupled to the SIS 18 synchrotron. The average beam intensity was 2 ×109ions/spill, with a pulsed beam structure of 1 s spill duration (SIS extraction) and a repetition cycle of 4 s. The beam impinged on a 9Be target with a thickness of 1.6 g/cm2at the entrance of the fragment separator (FRS) [20]. The selection of the ions of interest, from this point to the detection system, was done with the Bρ-E-Bρ method by using the FRS as an achromatic spectrometer. Neutron-rich nuclei “south-east” of 208Pb in the chart of nuclides were produced by using two FRS settings centered on 211Hg and 215Tl. To minimize the number of ionic charge states of the secondary beam a niobium layer with a thickness of 223 mg/cm2was placed behind the Be target. In addition, a homogeneous Al degrader with a thickness of 2.5 g/cm2was placed at the first FRS focal plane (S1) in combination with thick Cu slits, which served to reduce the contribution of fission fragments and primary beam charge states with magnetic rigidity Bρ initially similar to that of the setting isotope. A wedge-shaped Al degrader with a thickness of 3874 mg/cm2was employed as achromatic degrader at the intermediate focal plane S2 (see Fig. 1). Ion species were identified by means of standard FRS tracking detectors. Two plastic scintillators located at S2 and at the final focal plane S4 were used to measure the time of flight (tTOF) of the ions. Two systems of time projection chambers (TPCs) [21] placed at S4 and S2 allowed us to determine accurate Bρ values for each ion by measuring their trajectory with respect to the central fragment. The measured tTOF in combination with the Bρ provided the necessary information to calculate the mass-to-charge ratio (A/q)on an event-by-event basis. The resolution thus obtained in A/q was 2.5‰full width at half maximum (FWHM). To determine the atomic number Z, two fast multiple sampling ionization chambers (MUSICs) [22] were placed in the S4 experimental area. Although the detected nuclei were mainly bare, H- and He-like charge states were also detected in the MUSICs. These events were corrected by combining the information of the two MUSICs and calculating the energy loss in the S2 degrader following the method applied in previous studies in this mass region [23–26]. In addition, it was needed to treat the gain fluctuations in the MUSIC detectors caused by the variations of the temperature in the experimental hall, and consequent changes in gas pressure, which were also corrected numerically [27]. The final resolution obtained in Zfor the Pb-Bi region was of 6‰FWHM. Finally, the Zversus A/q particle identification diagram (PID) was experimentally validated with a dedicated run. 205Bi ions were implanted into a passive plastic stopper and the decays of well-known isomeric transitions [28] were measured with HPGe detectors. The PID obtained, including nuclei produced in both FRS settings with all the statistics accumulated during the FIG. 1. Scheme of FRS facility (see text for details). 064322-2 β-DECAY HALF-LIVES AND β-DELAYED . . . PHYSICAL REVIEW C 95, 064322 (2017) A/Z 2.58 2.6 2.62 2.64 2.66 2.68 2.7 2.72 Z 77 78 79 80 81 82 83 84 85 86 87 88 0 1 2 3 4 5 6 7 8 9 Au 206 Hg 209 Tl 212 Pb 215 Bi 218 Po 221 At 224 Rn 227 Fr 230 FIG. 2. Particle identification diagram (PID) with the total statistics of the 211Hg and 215Tl settings. experiment, is shown in Fig. 2. All identified nuclei were already reported in previous experiments [29,30]. A. Implantation and decay-detection system The secondary beam of neutron-rich isotopes was focused at the final focal plane S4 of the FRS. A third Al degrader with variable thickness was adjusted in order to slow down the ions of interest and to implant them into the central region of an active stopper named “silicon implantation beta absorber” (SIMBA) [31,32]. SIMBA enabled position and energy measurement of heavy charged ions as well as charged particles from αand βdecays. The main difference between the SIMBA system employed here and previous versions was the smaller number of Si detectors required to stop and implant the ions in the present experiment, which had a higher atomic number (Z∼82) than those measured in the past (Z∼50, [31]). In addition, the geometry and overall size of SIMBA were also modified in order to optimize neutron detection (see FIG. 3. Picture of SIMBA without its cylindrical coverage of 11.5 cm diameter. below). The present SIMBA version consisted of a stack of nine highly segmented Si detectors (see Figs. 3and 4). Thefirst twolayers,called XY-trackingdetectors,consisted of single-sided Si-strip detectors (SSSDs) with their strips in orthogonal orientation with respect to each other. They were used for determining accurately the ion position in the transversal plane of the beam. A center-of-gravity method applied to the charge shared over all the strips allowed us to determine the ion position with an accuracy of ±1mm 2[27,34], corresponding to one pixel in a silicon layer of SIMBA. The implant and decay-sensitive region consisted of two SSSD layers (front absorbers), three double-sided silicon stripped detectors (DSSSDs) designated as implantation layers A, B, and C, and two SSSD layers (rear absorbers). The energy deposited by the ions along these seven Si detectors was used to detect whether the ion was implanted or if it punched through, as well as to determine the corresponding implant layer or depth. The segmentation of the DSSSDs was 60-fold in the Xand 40-fold in the Ydirection, with a strip width of 1 mm. Figure 5shows the total number of implanted ions for each isotope in the DSSSDs of SIMBA. The energy deposited by βdecays in each Si-electrode showed, as expected, a continuum spectrum which extended up to ∼2–3 MeV. The energy deposited in the DSSSDs was determined from the response of the Ystrips, which were readout via logarithmic preamplifiers. The latter allowed clear separation of the ion implants and decays in the spectrum [see Table Iand Figs. 6(a) and 6(b)]. A pulse generator was used to perform the gain-matching of the Ystrips. An accurate energy calibration of layers A and B was accomplished using well-known αdecays from several At, Bi, Rn, and Po isotopes produced in the decay of implanted Tl, Pb, and Bi nuclei [see Figs. 6(a) and 6(b)]. No αemitter was implanted in layer C and, therefore, a coarse energy calibration of the latter was made by using only the broad βspectrum [Fig. 6(d)]. Nevertheless, for implant-βtime correlations only an energy window covering the broad βspectrum is required and, therefore, an accurate energy calibration is of secondary relevance for this data analysis. SIMBA was placed inside the cylindrical hole (23 cm diameter) of the beta delayed neutron (BELEN) detector [46– 49]. BELEN consisted of an array of 30 3He counters of FIG. 4. Schematic view of SIMBA: From left to right (beam direction) the two XY-tracking silicons, the front absorber, the implantation layers A,B,andCand the rear absorber layers. Adapted from Refs. [32,33]. 064322-3 R. CABALLERO-FOLCH et al. PHYSICAL REVIEW C 95, 064322 (2017) Pt 200-205 Au 203-209 Hg 206-213 Tl 209-216 Pb 212-219 Bi 215-222 Number of implants per isotope 1 10 2 10 3 10 FIG. 5. Number of implanted nuclei of each isotope in the DSSSDs of SIMBA. 2.54 cm diameter, embedded in a high-density polyethylene (PE) matrix (Fig. 7). The 3He tubes were distributed in two rings: an inner one with a radius of 14.5 cm and 10 tubes of 10 atm, and the outer ring with a radius of 18.5 cm and 20 tubes of 20 atm. This configuration was designed by means of GEANT4 [50,51] and MCNPX [52–54] Monte Carlo (MC) simulations in order to achieve a high and flat detection efficiency (see Fig. 8). At a neutron energy up to 1 MeV the detection efficiency was 40(2)%, and it decreased to 25% at 5 MeV. The MC codes were experimentally validated at En=2.3 MeV with a dedicated measurement of a wellcalibrated 252Cf source. The Qβn window of the exotic nuclei involved in the present measurement spans neutron energies up to 2.5 MeV [55,56]. In this energy range, the average neutron detection efficiency TABLE I. αlines observed in SIMBA in layers A and B and their associated nuclei [see some of them in Figs. 6(b) and 6(c)]. αenergy SIMBA αemitter Precursor (keV) layer implanted 5304.3 [35]A,B 210Po (Implanted) 5869.5 [36]A 211At (Implanted) 6002.4 [37]A 218Po 218Bi, 218Pb 6050.8 [38]A 212Bi 212Tl 6208.0 [39]A 219At 219Bi 6288.1 [40]A 220Rn 220Bi 6300.0 [38]B 212Bi 212Tl 6340.0 [38]B 212Bi 212Tl 6537.0 [41]A 217Po 217Pb 6622.9 [36]A 211Bi 211Tl 6778.3 [42]A 216Po 216Pb 7386.1 [43]A 215Po 215Pb 7450.3 [36]A 211Po 211At 7686.82 [44]A,B 214Po 214Pb, 214Tl 8375.9 [45]A,B 213Po 213Tl was 38%; this value was used in the data analysis (see Sec. III). By using the calibrated 252Cf source a gain matching of the responseofall 30 counters wascarried out before the experiment. The stability of the overall detector response was checked regularly during the experiment. The accumulated spectrum for all 30 tubes during the 211Hg setting is shown Fig. 9. The energy window considered in the data analysis as neutron events comprises the range from a low threshold of the 191 keV peak up to the end of the main peak of the reaction [see Eq. (1)] at 765 keV. The latter peak corresponds to the kinetic energy of the two reaction products, a triton and a proton: 3He +n−→ 3H+1H+765 keV.(1) To reduce the neutronbackgroundinBELENtwoadditional elements were implemented in the setup. On one hand, a PE wall with a thickness of 30 cm was installed upstream from BELEN to shield the detector from neutron background induced by the secondary beam (see Fig. 7). This wall had a central hole of 180 mm in the Xdirection and 70 mm in the Y direction to let the beam into SIMBA. In addition, a layer of borated rubber was attached to the rear of the PE wall in order to absorb thermalized neutrons that could eventually reach the rear side of the wall. On the other hand, the BELEN detector wassurroundedby20cmof PE shielding (see Fig. 7) in order to moderate and absorb scattered neutrons from the surroundings. The GSI multibranch system (MBS) [57] was used to acquire data from the FRS tracking detectors and SIMBA. This data-acquisition system (DACQ) was triggered by a scintillator at S4 with an efficiency of ∼100% for heavy ions. The MBS was also triggered by high-energy implant and low-energy β-decay events in SIMBA. On the other hand, the neutron data from BELEN were acquired by using a digital self-triggered system [58] based on SIS3302 VME digitizers from Struck Innovative Systems [59]. Each module had 8 input channels running at 100 MHz sampling rate with an ADC resolution of 16 bit. A common clock was used for time stamping the events acquired in the BELEN and MBS DACQ systems with 20 ns resolution. In this way, ion-implant versus β-decay time correlations and ion-β-neutron time correlations could be built over an arbitrarily long time window and in both forward (increasing) and backward (decreasing) time directions. The latter aspect was a key feature in the analysis stage to determine reliably the background level (see Sec. III). III. DETERMINATION OF β-DECAY HALF-LIVES AND P1nVALUES The methodology followed here for the analysis of the β-decay half-lives is similar to the approach successfully applied in previous experiments at isotope separator on-line (ISOL) and fragmentation facilities, such as described in Refs. [16,31]. There are two fundamental aspects to this data analysis; namely, a reliable background characterization of β and neutron events and the spatial- and temporal-correlation approach. We describe first the analysis methodology from a rather general perspective and afterwards we show in detail its application to one of the largest implant statistics case, which is 213Tl. The latter is also used to illustrate the background treatment in the analysis. 064322-4 β-DECAY HALF-LIVES AND β-DELAYED . . . PHYSICAL REVIEW C 95, 064322 (2017) Energy (keV) 5000 10000 15000 20000 Counts 2 10 3 10 4 10 5 10 Bi setting 205 during a peaksα Main region Implantation 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 15000 16000 keV 7450 keV 5869.5 Layer A (a) Energy (keV) 2000 4000 6000 8000 10000 Counts 1 10 2 10 3 10 4 10 decaysβ linesα 8375.9 keV 7686.8 keV 6778.5 keV 5304.4 keV 5869.5 keV 7450.3 keV Layer A (b) Energy (keV) 2000 4000 6000 8000 10000 Counts 1 10 2 10 3 10 4 10 decaysβ linesα 5304.3 keV 7686.8 keV 8375.9 keV 6300.0 + 6340 keV Layer B (c) Energy (keV) 2000 4000 6000 8000 10000 Counts 1 10 2 10 3 10 4 10 decaysβ Layer C (d) FIG. 6. Calibrated energy spectra for SIMBA layers: A (top), B and C (bottom). Let us consider one specific isotope i.TheBateman analytical expression [60] describes the time evolution of its abundance Ni(t). In this analysis we assumed that only the parent (N1) and daughter (N2) decays are contributing to the decay curve. This assumption is justified because FIG. 7. (left) Top view of BELEN and the front PE shielding wall (beam enters from the right-hand side). (right) Picture of BELEN detector showing the two rings of counters, the central hole where SIMBA(seeFig.3) was placed, and the extra 20 cm of PE shielding around. all granddaughters of the analyzed nuclei are either stable nuclei or have a half-life much longer than that of the parent and daughter nuclei. The resulting expression based on this assumption is given by 2  i=1 λiNi(t)=[λ1N1(t)+λ2N2(t)],(2) where λ1=ln(2)/T1/2is the decay constant for the implanted nucleus (i=1), with unknown half-life T1/2, and λ2is the decay constant of the daughter nucleus (i=2). As shown below, in many cases even the contribution of the daughter nucleus was very small. Regarding the spatial correlation, we considered an implant and a decay event to be spatially associated when the β-decay position measured in layers A, B, or C of SIMBA was within a correlation region of 3 mm2around the implant position measured in the same layer. Extending this condition to neighboring layers did not improve noticeably the statistics and was therefore disregarded. In general, smaller and larger 064322-5 R. CABALLERO-FOLCH et al. PHYSICAL REVIEW C 95, 064322 (2017) Energy (MeV) 4− 10 3− 10 2− 10 1− 10 1 Neutron detection efficiency (%) 5 10 15 20 25 30 35 40 45 Total efficiency Inner ring Outer ring FIG. 8. MCNPX simulation of the neutron detection efficiency of BELEN as a function of the neutron energy. The lower curves refer the two rings of 3He counters. See text for details. correlation areas were not found to provide a better result in terms of statistics and signal-to-background ratio in the time-correlation diagrams [27]. Regarding the time correlation, the methodology followed here consisted of building a correlation histogram for every implantofacertainspecies icontaining its time differencewith respect to all, forward and backward, βevents within a broad time window tT1/2. In this analysis we used ten times the expected half-life, t≃10T1/2. As demonstrated below, the uncorrelated background rate is a constant value, which can be referred to as b. In this case, the probability density function describing the time dependence of the correlation distribution is given by [61] ρ(λ1,t)=εβb+εβλ1e−λ1t +εβ λ1λ2 λ1−λ2 (e−λ2t−e−λ1t),(3) where εβis the β-detection efficiency in SIMBA. Thus, for a certain number N1(0) of implanted events, the total number Nβof βparticles detected at a time twith respect to the implantation time (t=0) is given by NAllβ β(t)=N1(0)ρ(λ1,t)t =εβ[λ1N1(t)+λ2N2(t)+b]t, (4) where NAllβ β(t) is the total number of detected decays at a time t,b is the βbackground normalized and corrected by εβ, and t corresponds to the bin time width used in the implant-βtime-correlation histogram. The time evolution of the parent abundance is described by N1(t)=N1(0)e−λ1t, whereas the contribution of the daughter is given by N2(t)= N1(0) λ1 λ1−λ2(e−λ2t−e−λ1t), assuming N2(0) =0. In the data Energy (keV) 100 200 300 400 500 600 700 800 900 1000 Counts 0 5000 10000 15000 20000 25000 30000 35000 FIG. 9. Energy spectrum measured with all 30 3He tubes of BELEN during the run with the 211Hg setting. analysis, the common factor N1(0)εβin Eq. (4) is derived from the first bin in the correlation diagram [27]. In this way the quantity of interest (T1/2) can be reliably determined without knowing explicitly the β-detection efficiency. A. Reference analysis of 213Tl half-life The thallium isotope 213Tl was implanted with large statistics (1015 implants), so we used this case to establish the analysis methodology on a reliable statistical basis. The βbackground showed a dependency with the time structure of the pulsed primary beam. Indeed, during beam extraction from SIS (1 s) the overall background level of β-like events in SIMBA was ∼40% higher than during the time-interval between spills [27]. This feature led to a better signal-to- background ratio in the implant-βtime-correlation histograms when only β-events outside of the spill time intervals were considered in the correlations, when compared with the same diagram including β-events inside and outside the spill. With this restriction in mind, the background level evaluation was based on time backward (t<0) implant-βcorrelations, i.e., the time difference between each implant and all the βevents occurring before it, within a broad time window (t ≃10T1/2) and in the same correlation area used in the forward analysis of 3×3mm 2. The background level thus determined allows one to adjust the parameter bin Eq. (3). This approach is illustrated in Fig. 10 for the case of 213Tl, which shows backward (negative) and forward (positive) implant-βcorrelations. The contribution to the measured βactivity from decays of other nuclei can be assumed to be negligible due to the very low average implantation rate of 2 ×10−5ions s−1pixel−1. By using Eq. (4), a binned maximum likelihood (ML) [62] analysis of the time correlation histogram was carried out, which yielded a half-life for 213Tl of T1/2=23.8± 4.4 s. Comparison with other literature values is made in Sec. IV. 064322-6 β-DECAY HALF-LIVES AND β-DELAYED . . . PHYSICAL REVIEW C 95, 064322 (2017) Time (s) 300−200−100−0 100 200 300 Counts 0 5 10 15 20 25 30 35 40 45 4.4) s±= (23.8 1/2 Tl: T 213 Fit data (bin = 6s) Tl 213 Decay of Daughter decay Background FIG. 10. 213Tl implant-βtime diagram using a correlation area of 3 ×3mm 2and βevents detected outside of the spill. The red line shows the result of a binned maximum likelihood (ML) analysis. The decay curve shows mostly the contribution of 213Tl decay (green line), with a minor contribution from the daughter 213Pb (dashed blue line). B. Neutron branching ratio for 213Tl The implant-βneutron correlations were analyzed by selecting a correlation window of n t=400 μs forward and backward in time, following each βdetection. This time interval was determined according to the expected neutron moderation time in polyethylene. Considering the βefficiency εβas a constant value over the range of energies of interest, the P1nvalue can be directly obtained from the subtraction of time-forward and time-backward β-neutron correlated events, P1n(%)=1 εn Nfwd βn −Nbkd βn Nβ ×100,(5) where εnis the BELEN neutron efficiency, Nfwd βn is the number of forward correlated implant-β-neutron events, and Nβis the number of parent βdecays. Nbkd βn designates the backward β-neutron correlations, which were used to define the uncorrelated neutron background level. The efficiency can be considered flat over the energy range of interest according to the Qβn values of the implanted isotopes (100 keV to 2.5 MeV; [55,56]), with a constant value of 38% and a relative uncertainty of 5% (see Fig. 8). This overall uncertainty includes the contributions of statistical errors for Nfwd βn ,Nbkd βn , and Nβtogether with the uncertainty for the BELEN detector efficiency from the fluctuations over the energy range. For 213Tl we measured five forward and no backward correlated neutrons (Fig. 11), which yielded a P1nvalue of 7.6% ±3.4%. C. Thallium isotopes: 211–216Tl Five more thallium isotopes were measured and their β-decay half-lives and neutron-branching ratios were analyzed s)μTime ( 400−300−200−100−0 100 200 300 400 Counts 0 0.2 0.4 0.6 0.8 13.4) %±= (7.6 1n Tl: P 213 FIG. 11. β-neutron correlation events during the 213Tl implant-β correlation time. following the approach described above for 213Tl. The implantβtime-correlation histograms for all of them, 211,212,214–216Tl are shown in Fig. 12. The binned ML analysis (dashed-dotted line on diagrams) yields T1/2=76.5±17.8sfor211Tl, T1/2=30.9±8.0sfor212Tl, and T1/2=11.0±2.4sfor 214Tl. An almost negligible contribution from the much slower decay of the daughter nuclei (211,212,214Pb) can be observed in these three cases. The most exotic thallium species implanted, 215,216Tl, were measured with rather limited statistics of only 281 and 99 implants, respectively. In this case, we noticed a slight improvement in the signal-to-background ratio in the correlation histograms when the correlation area was enlarged from 3 ×3mm 2to 5 ×5mm 2.The ML analysis also shown in diagrams of Fig. 12 yielded a half-lives T1/2=9.7±3.8sfor215Tl and T1/2=5.9±3.3s for 216Tl. The neutron-data analysis showed the presence of only one correlated implant-β-neutron event for each of 211,212,215Tl, which yields neutron-branching ratios of 2.2(2.2)%, 1.8(1.8)% and 4.6(4.6)%, respectively. For these three cases, given the low number of events compatible with the physical boundary, we have alternatively calculated a conservative upper limit based on the Bayesian approach [63], which yields upper limits of 10%, 8%, and 20% at a confidence level (CL) of 95%. On the other hand, with BELEN we were able to observe a rather large number (10) of implantβ-neutron correlated events for 214Tl (histogram also shown in Fig. 12), resulting in a P1nvalue of 34.3% ±12.2%. No single correlated or uncorrelated event was detected for 216Tl which, according to the implantation statistics obtained, led to an upper limit of 11.5% and a Bayesian upper limit of P1n<52% at the 95% CL. Concerning the other implanted species, 209,210Tl, the implantation statistics was not enough to determine either their half-lives or the neutron-branching ratios. 064322-7 R. CABALLERO-FOLCH et al. PHYSICAL REVIEW C 95, 064322 (2017) Time (s) 600 −400 −200 − Counts 5 10 15 20 25 30 35 40 17.8) s±= (76.5 1/2 Tl: T 211 Fit data (bin = 20s) Tl 211 Decay of Daughter decay Background Time (s) 300 −200 −100 − Counts 0 5 10 15 20 25 30 35 40 45 8.0) s±= (30.9 1/2 Tl: T 212 Fit data (bin = 8s) Tl 212 Decay of Daughter decay Background Time (s) 100 −80 −60 −40 −20 − Counts 0 5 10 15 20 25 30 2.4) s±= (11.0 1/2 Tl: T 214 Fit data (bin = 4s) Tl 214 Decay of Daughter decay Background Time (s) 120 −100 −80 −60 −40 −20 − Counts 0 5 10 15 20 25 3.8) s±= (9.7 1/2 Tl: T 215 Fit data (bin = 4s) Tl 215 Decay of Daughter decay Background Time (s) 80 −60 −40 −20 − Counts 0 2 4 6 8 10 12 3.3) s±= (5.9 1/2 Tl: T 216 Fit data (bin = 5s) Tl 216 Decay of Daughter decay Background s) μ Time ( 400 −300 −200 −100 − 0 200 400 600 0 100 200 300 0 20 40 60 80 100 0 20 40 60 80 100 120 0 20 40 60 80 0 100 200 300 400 Counts 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 212.2) %±= (34.3 1n Tl: P 214 FIG. 12. Implant-βcorrelation histograms for 211,212,214–216Tl. The diagrams for 215,216Tl were obtained by using a correlation area of 5×5mm 2. The last histogram corresponds to the implant-β-neutron time correlations for 214Tl. D. Lead isotopes: 215–218Pb The lead isotopes 212–219Pb were identified in the FRS and implanted in SIMBA. The 215–218Pb nuclei were implanted with enough statistics for a reliable half-life analysis. 214Pb was also implanted with large statistics (see Fig. 5), but its half-life of 1608 ±54 s [64] was too long for our analysis methodology and instrumentation. The ML analyses for the implant-β correlation diagrams of 215–218Pb are shown in Fig. 13.The 215Pb analysis yielded a half-life of T1/2=98.4±30.8s.As 064322-8 β-DECAY HALF-LIVES AND β-DELAYED . . . PHYSICAL REVIEW C 95, 064322 (2017) Time (s) 1500 −1000 −500 − Counts 80 100 120 140 160 180 30.8) s±= (98.4 1/2 Pb: T 215 Fit data (bin = 64s) Pb 215 Decay of Daughter decay Background Time (s) 1000 −800 −600 −400 −200 − Counts 30 40 50 60 70 80 90 100 110 17.5) s±= (99.4 1/2 Pb: T 216 Fit data (bin = 32s) Pb 216 Decay of Daughter decay Background correlations βimplant- Time (s) 250 −200 −150 −100 −50 − Counts 0 5 10 15 20 25 30 5.3) s±= (19.9 1/2 Pb: T 217 Fit data (bin = 8s) Pb 217 Decay of Daughter decay Background Time (s) 250 −200 −150 −100 −50 − 0 500 1000 1500 0 200 400 600 800 1000 0 50 100 150 200 250 0 50 100 150 200 250 Counts 0 2 4 6 8 10 12 14 16 6.8) s±= (14.8 1/2 Pb: T 218 Fit data (bin = 8s) Pb 218 Decay of Daughter decay Background FIG. 13. Half-life analysis for implant-βcorrelation diagrams of 215–218Pb. can be observed on its diagram, contributions from 215Pb and its daughter 215Bi are present in the correlation histogram. For the case of the measurement of 216Pb, it allowed us to carry out a cross-check of the aforementioned analysis methodology, because its half-life can be determined by means of two different methods: implant-βand implant-αcorrelations. The former is also illustrated in Fig. 13, which shows the implant-βcorrelation and the result of the ML analysis. On the other hand, the peak of αparticles at 6778.3 keV, clearly identified in the energy spectrum of SIMBA [see Fig. 6(b)], corresponds to the decay of its granddaughter nucleus 216Po. Taking into account that the half-life of 216Po, 145 ±2 ms [40], is much shorter than that of the direct daughter 216Bi, 2.25 ±5min[40], it was possible to apply the method described in Ref. [65] to obtain the half-life of 216Pb. With this method we determined a half-life of T1/2=99.4±11.7s(see diagram of Fig. 14) which is in perfect agreement with the one obtained applying the conventional method described above for implant-βtime correlation, T1/2=99.4±17.5s.The accuracy in the analysis of 217Pb and 218Pb was mainly limited by the implantation statistics, where there was 436 and 235 implants, respectively. However, a reliable ML analysis was possible from their implant-βcorrelation diagrams, as shown in the low diagrams of Fig. 13. The resulting half-lives were T1/2=19.9±5.3sfor217Pb and T1/2=14.8±6.8sfor 218Pb. According to the negative Qβn values for all these lead isotopes, no neutron branching emission is expected for them. Time (s) 2000−1500−1000−500−0 500 1000 1500 2000 Counts 0 5 10 15 20 25 30 11.7) s±= (99.4 1/2 Pb T 216 Fit data (bin = 32s) Pb 216 Decay of Daughter decay Background correlations αimplant- FIG. 14. Half-life analysis of 216Pb via implant-αcorrelations. 064322-9 R. CABALLERO-FOLCH et al. PHYSICAL REVIEW C 95, 064322 (2017) [33] C. B. Hinke, Ph.D. thesis, Technische Universität München, 2010 (unpublished). [34] K. Smith, Ph.D. thesis, University of Notre Dame, 2014 (unpublished). [35] F. Kondev, Nucl. Data Sheets 109,1527 (2008). [36] F. Kondev and S. Lalkovski, Nucl. Data Sheets 112,707 (2011). [37] S.-C. Wu, Nucl. Data Sheets 110,681 (2009). [38] M. Martin, Nucl. Data Sheets 108,1583 (2007). [39] B. Singh, G. Mukherjee, D. Abriola, S. Basu, P. Demetriou, A. Jain, S. Kumar, S. Singh, and J. Tuli, Nucl. Data Sheets 114, 2023 (2013). [40] S.-C. Wu, Nucl. Data Sheets 108,1057 (2007). [41] M. Basunia, Nucl. Data Sheets 108,633 (2007). [42] E. Browne, Nucl. Data Sheets 104,427 (2005). [43] B. Singh, D. Abriola, C. Baglin, V. Demetriou, T. Johnson, E. McCutchan, G. Mukherjee, S. Singh, A. Sonzogni, and J. Tuli, Nucl. Data Sheets 114,661 (2013). [44] M. Basunia, Nucl. Data Sheets 121,561 (2014). [45] J. Chen and F. Kondev, Nucl. Data Sheets 126,373 (2015). [46] M. Gómez-Hornillos, J. Rissanen, J. Taín, A. Algora, K. Kratz, G. Lhersonneau, B. Pfeiffer, J. Agramunt, D. Cano-Ott, V. Gorlychev, R. Caballero-Folch, T. Martínez, L. Achouri, F. Calvino, G. Cortès, T. Eronen, A. García, M. Parlog, Z. Podolyak, C. Pretel, and E. Valencia, Hyperfine Interact. 223, 185 (2014). [47] J. Agramunt, A. Garcia, A. Algora, J. Äystö, R. Caballero-Folch, F. Calvino, D. Cano-Ott, G. Cortes, C. Domingo-Pardo, T. Eronen et al.,Nucl. Data Sheets 120,74 (2014). [48] V. Gorlychev, Ph.D.thesis, UniversitatPolitècnica deCatalunya, 2014 (unpublished). [49] A. Torner, J. Agramunt, A. Algora, L. Batet, R. Caballero-Folch, F. Calviño, D. Cano-Ott, A. García, G. Cortés, I. Dillmann, C. Domingo-Pardo, M. Gómez-Hornillos, V. Gorlychev, M. Marta, T. Martínez, A. Poch, C. Pretel, A. Riego, and J. Taín, Technical Design Report of the Beta-Delayed Neutron Detector (BELEN) for NUSTAR (DESPEC), Tech. Rep. (Universitat Politècnica de Catalunya, Barcelona, 2014). [50] A. Riego, Ph.D. thesis, Universitat Politècnica de Catalunya, 2016 (unpublished). [51] S. Agostinelli, J. Allison, K. Amako, J. Apostolakis, H. Araujo, P. Arce, M. Asai, D. Axen, S. Banerjee, G. Barrand et al., Nucl. Instrum. Methods Phys. Res., Sect. A 506,250 (2003). [52] D. B. Pelowitz et al.,MCNPX Users Manual Version 2.5.0, Tech. Rep. (Los Alamos National Laboratory, 2005). [53] G. Fishman, Monte Carlo Concepts, Algorithms and Applications (1996). [54] R. Y. Rubinstein and D. P. Kroese, Simulation and the Monte Carlo Method (1981). [55] G. Audi, M. Wang, A. Wapstra, F. Kondev, M. MacCormick, X. Xu, and B. Pfeiffer, Chin. Phys. C 36,1287 (2012). [56] M. Wang, G. Audi, A. Wapstra, F. Kondev, M. MacCormick, X. Xu, and B. Pfeiffer, Chin. Phys. C 36,1603 (2012). [57] H. N.Kurz, GSI Data Acquisition System MBS, Release Notes v5.1 (2010). [58] J. Agramunt, J. Tain, M. Gómez-Hornillos, A. Garcia, F. Albiol, A. Algora, R. Caballero-Folch, F. Calviño, D. Cano-Ott, G. Cortés et al.,Nucl. Instrum. Methods Phys. Res., Sect. A 807, 69 (2016). [59] http://www.struck.de/sis3302.htm [60] H. Bateman, Proc. Cambridge Philos. Soc. 15, 423 (1910). [61] M. Bernas, P. Armbruster, J. Bocquet, R. Brissot, H. Faust, C. Kozhuharov, and J. Sida, Z. Phys. A 336,41 (1990). [62] J. G. Proakis, M. Salehi, N. Zhou, and X. Li, Communication Systems Engineering (Prentice-Hall, Englewood Cliffs, 1994), Vol. 1. [63] A. Gelman, J. B. Carlin, H. S. Stern, and D. B. Rubin, Bayesian Data Analysis (Taylor & Francis, 2014), Vol. 2. [64] Brookhaven National Laboratory, USA, http://www. nndc.bnl.gov/nudat2/indx_dec.jsp. [65] A. Morales, G. Benzoni, A. Gottardo, J. Valiente-Dobón, N. Blasi, A. Bracco, F. Camera, F. Crespi, A. Corsi, S. Leoni et al., Phys. Rev. C 89,014324 (2014). [66] D. Fink, T. Cocolios, A. Andreyev, S. Antalic, A. Barzakh, B. Bastin, D. Fedorov, V. Fedosseev, K. Flanagan, L. Ghys et al., Phys. Rev. X 5,011018 (2015). [67] P. Möller, B. Pfeiffer, and K.-L. Kratz, Phys. Rev. C 67,055802 (2003). [68] I. Borzov, Nucl. Phys. A 777,645 (2006). [69] H. Koura, T. Tachibana, M. Uno, and M. Yamada, Prog. Theor. Phys. 113,305 (2005). [70] T. Marketin, L. Huther, and G. Martínez-Pinedo, Phys.Rev.C 93,025805 (2016). [71] I. N. Borzov (private communication). [72] M. Mumpower, T. Kawano, and P. Möller, Phys. Rev. C 94, 064317 (2016). [73] D. Craig and H. Taylor, J. Phys. G: Nucl. Phys. 10,1133 (1984). [74] A. Pakkanen, T. Komppa, and H. Helppi, Nucl. Phys. A 184, 157 (1972). [75] C. Wennemann, W.-D. Schmidt-Ott, T. Hild, K. Krumbholz, V. Kunze, F. Meissner, H. Keller, R. Kirchner, and E. Roeckl, Z. Phys. A: Hadrons Nucl. 347,185 (1994). [76] A. Morales, G. Benzoni, N. Al-Dahan, S. Vergani, Z. Podolyák, P. Regan, T. Swan, J. Valiente-Dobón, A. Bracco, P. Boutachkov et al.,Europhys. Lett. 111,52001 (2015). [77] Z. Li, Z. Jinhua, Z. Jiwen, W. Jicheng, Q. Zhi, Y. Youngfeng, Z. Chun, J. Genming, G. Guanghui, D. Yifei et al.,Phys. Rev. C 58,156 (1998). [78] G. Benzoni, A. Morales, J. Valiente-Dobón, A. Gottardo, A. Bracco, F. Camera, F. Crespi, A. Corsi, S. Leoni, B. Million et al.,Phys. Lett. B 715,293 (2012). [79] H. Sagawa, A. Arima, and O. Scholten, Nucl. Phys. A 474,155 (1987). [80] P. Goddard, P. D. Stevenson, and A. Rios, Phys. Rev. Lett. 110, 032503 (2013). [81] H. Nakada, Phys. Rev. C 92,044307 (2015). [82] A. Gottardo, J. Valiente-Dobón, G. Benzoni, R. Nicolini, A. Gadea, S. Lunardi, P. Boutachkov, A. Bruce, M. Górska, J. Grebosz et al.,Phys. Rev. Lett. 109,162502 (2012). [83] Zs. Podolyák (private communication). [84] T. Kurtukian-Nieto, J. Benlliure, and K.-H. Schmidt, Nucl. Instrum. Methods Phys. Res., Sect. A 589,472 (2008). 064322-16