scieee AI-readable full text Open interactive document viewer

Non-Invasive Method to Detect Infection with Mycobacterium tuberculosis Complex in Wild Boar by Measurement of Volatile Organic Compounds Obtained from Feces with an Electronic Nose System

Beleño Sáenz, Kelvin de Jesús; Martín Cáceres-Tarazona, Juan; Nol, Pauline; Jaimes-Mogollón, Aylen Lisset; Gualdrón Guerrero, Oscar Eduardo; Durán Acevedo, Cristhian Manuel; Vicente, Joaquín; Torres Sánchez, María José

Abstract

More effective methods to detect bovine tuberculosis, caused by Mycobacterium bovis, in wildlife, is of paramount importance for preventing disease spread to other wild animals, livestock, and human beings. In this study, we analyzed the volatile organic compounds emitted by fecal samples collected from free-ranging wild boar captured in Doñana National Park, Spain, with an electronic nose system based on organically-functionalized gold nanoparticles. The animals were separated by the age group for performing the analysis. Adult (>24 months) and sub-adult (12–24 months) animals were anesthetized before sample collection, whereas the juvenile (<12 months) animals were manually restrained while collecting the sample. Good accuracy was obtained for the adult and sub-adult classification models: 100% during the training phase and 88.9% during the testing phase for the adult animals, and 100% during both the training and testing phase for the sub-adult animals, respectively. The results obtained could be important for the further development of a non-invasive and less expensive detection method of bovine tuberculosis in wildlife populations.

Full text

sensors Article Non-Invasive Method to Detect Infection with Mycobacterium tuberculosis Complex in Wild Boar by Measurement of Volatile Organic Compounds Obtained from Feces with an Electronic Nose System Kelvin de Jesús Beleño-Sáenz 1,2, Juan Martín Cáceres-Tarazona 2, Pauline Nol 3,†, Aylen Lisset Jaimes-Mogollón2, Oscar Eduardo Gualdrón-Guerrero 2, Cristhian Manuel Durán-Acevedo 2, Jose Angel Barasona 4, Joaquin Vicente 5, María JoséTorres 6, Tesfalem Geremariam Welearegay 7, Lars Österlund 7, Jack Rhyan 3 and Radu Ionescu 8,*   Citation: de Jesús Beleño-Sáenz, K.; Cáceres-Tarazona, J.M.; Nol, P.; Jaimes-Mogollón, A.L.; Gualdrón-Guerrero, O.E.; Durán-Acevedo, C.M.; Barasona, J.A.; Vicente, J.; Torres, M.J.; Welearegay, T.G.; et al. Non-Invasive Method to Detect Infection with Mycobacterium tuberculosis Complex in Wild Boar by Measurement of Volatile Organic Compounds Obtained from Feces with an Electronic Nose System. Sensors 2021,21, 584. https:// doi.org/10.3390/s21020584 Received: 9 December 2020 Accepted: 13 January 2021 Published: 15 January 2021 Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. Copyright: © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/). 1Mechatronics Engineering Department, Universidad Autónoma del Caribe, Barranquilla 080020, Colombia; [email protected] 2 GISM Group, Faculty of Engineering and Architecture, University of Pamplona, Pamplona 543050, Colombia; [email protected] (J.M.C.-T.); [email protected] (A.L.J.-M.); oscar[email protected] (O.E.G.-G.); [email protected] (C.M.D.-A.) 3Centers for Epidemiology and Animal Health, Veterinary Services, Animal and Plant Health Inspection, Service, United States Department of Agriculture, Fort Collins, CO 80526, USA; [email protected] (P.N.); [email protected] (J.R.) 4VISAVET Health Surveillance Centre, Animal Health Department, Faculty of Veterinary Medicine, Complutense University of Madrid, 28040 Madrid, Spain; [email protected] 5 SaBio Instituto de Investigación en Recursos Cinegéticos IREC, ETSIA Ciudad Real, University of Castilla La Mancha & CSIC, 13003 Ciudad Real, Spain; [email protected] 6Biomedical Institute of Sevilla (IBiS), University of Seville, University Hospital Virgen del Rocío/CSIC, 41071 Seville, Spain; [email protected] 7The Ångström Laboratory, Department of Materials Science and Engineering Sciences, Uppsala University, P.O. Box 35, 75103 Uppsala, Sweden; [email protected] (T.G.W.); [email protected] (L.Ö.) 8Institute of Veterinary Medicine and Animal Sciences, Estonian University of Life Sciences, 51006 Tartu, Estonia *Correspondence: [email protected] † Current address: Colorado Division of Parks and Wildlife, Wildlife Health Program, Fort Collins, CO 80521, USA. Abstract: More effective methods to detect bovine tuberculosis, caused by Mycobacterium bovis, in wildlife, is of paramount importance for preventing disease spread to other wild animals, livestock, and human beings. In this study, we analyzed the volatile organic compounds emitted by fecal samples collected from free-ranging wild boar captured in Doñana National Park, Spain, with an electronic nose system based on organically-functionalized gold nanoparticles. The animals were separated by the age group for performing the analysis. Adult (>24 months) and sub-adult ( 12–24 months ) animals were anesthetized before sample collection, whereas the juvenile (<12 months) animals were manually restrained while collecting the sample. Good accuracy was obtained for the adult and sub-adult classification models: 100% during the training phase and 88.9% during the testing phase for the adult animals, and 100% during both the training and testing phase for the sub-adult animals, respectively. The results obtained could be important for the further development of a non-invasive and less expensive detection method of bovine tuberculosis in wildlife populations. Keywords: Sus scrofa; bovine tuberculosis; Mycobacterium bovis; diagnosis; feces; volatile organic compounds; chemical gas sensors; gold nanoparticles; organic ligands Sensors 2021,21, 584. https://doi.org/10.3390/s21020584 https://www.mdpi.com/journal/sensors Sensors 2021,21, 584 2 of 14 1. Introduction Bovine tuberculosis (bTB), caused by Mycobacterium bovis (M. bovis), is an emerging disease among wild animals in many parts of the world, and threatens to spill back as a potential source of infection for livestock and humans [ 1 ]. bTB can be easily transmitted from an infected animal to a non-infected one with whom it shares the same habitat, prevailing the aerogenic transmission. It can also be transmitted from animals to humans through consumption of meat products of infected animals, by contact with the blood of infected animals during slaughter, or through inhalation of air exhaled by infected animals [ 2 , 3 ]. In humans, bTB causes severe morbidity and even death, especially in the case of people involved in hunting and slaughter of animals without sufficient sanitary control. Standard bTB testing in live animals consists of single intradermal tuberculin tests for screening (caudal fold test or single cervical skin test) with a comparative cervical test, or an interferon gamma release assay test, as supplemental or confirmatory tests [ 4 – 6 ]. The final diagnosis of bovine tuberculosis requires post-mortem laboratory confirmation of the disease via histopathology, polymerase chain reaction, and bacteriological culture [ 5 , 6 ]. The detection of bovine tuberculosis in wildlife is generally done through techniques such as hunter-kill surveys, road-kill surveys, or actively capturing and/or killing animals for serologic testing and/or post-mortem examination [ 7 – 9 ]. There is need for less invasive, less expensive techniques to remotely detect bTB disease in wildlife populations. The detection of disease-specific volatile organic compounds (VOCs) from the feces may provide a solution for remote surveillance of wildlife. They reflect metabolomic changes produced by the disease in the host, and their analysis emerged as a promising approach for disease diagnosis and monitoring [10]. Two complementary methods are generally applied for VOC analysis: analytical techniques and electronic nose systems. The analytical techniques allow for the identification of disease-specific biomarkers. Yet, the concentration of many compounds emitted by biological samples is below the limit of detection of the analytical equipment and not all possible biomarkers are detected [ 11 ]. The electronic nose systems are formed of an array of cross-reactive chemical gas sensors, where each sensor lacks sufficient selectivity for detecting individual VOCs in a gaseous mixture, but, instead, the electronic nose system is trained to detect a disease-specific VOC pattern [ 12 ]. The electronic nose systems present advantages such as portability, easy operation, easy interpretation of results, and low cost [12]. Apparently, unique VOCs or patterns of VOCs were detected through analytical studies in the feces of cattle and white-tailed deer infected with M. bovis [ 13 , 14 ], and in the feces of goats infected with Mycobacterium avium paratuberculosis [ 15 , 16 ]. Very recently, in the first study of this kind performed on wild boar (Sus scrofa), we reported the identification of M. bovis-specific VOC patterns in the feces and breath of wild boar [ 17 ]. Similarly, electronic nose systems were also shown to be able to detect the VOC pattern of M. bovis in the headspace of serum from cattle and badgers [18,19], and in the breath of cattle [20]. In the present study, we report for the first time the detection of M. bovis from the measurement of the VOCs emitted from feces with an electronic nose system. This study was performed on free-ranging wild boar living in Doñana National Park, Spain, where bTB is endemic in the ungulate host community, including wild boar [ 21 ]. The successful development of this technology could lead to devices designed to remotely and noninvasively detect M. bovis and other pathogens in wildlife populations. 2. Materials and Methods 2.1. Animals and Samples The realization of this study was approved by the Commission of Animal Experiments from the University of Castilla-La Mancha, Spain (PR-2015-03-08). The procedures that were applied in this study were designed and implemented by scientists with experience in the field, after approval from the Spanish Ethics Committee in accordance with the European Commission Directive 86/609/EEC for animal experiments. Sensors 2021,21, 584 3 of 14 Fecal samples were obtained from 37 wild boars that were captured in Doñana National Park, Spain, as described in Nol et al. [ 17 ] and Barasona et al. [ 22 ]. The animals were captured at different sites from the park, located on a radius of 4.4 km, including Martinazo, Palacio, Santa Olalla, and Fuente del Duque. Boar were trapped in a portable cage and corral traps, as described in Barasona et al. [ 14 ]. Age determination was based on the recommendations given in Sáenz de Buruaga et al. [ 23 ]. Sub-adult and adult animals ( 12–24 months and >24 months, respectively) were sedated using a combination of tiletamine-zolazepam (100 mg/mL Zoletil ® , Virbac, Carros, France, 3 mg/kg dose) and medetomidine (Medetor ® , Virbac, Carros, France, 0.05 mg/kg dose), intramuscularly administered in the lateral region of animal’s gluteus with 5-mL darts (Telinject ® , Römerberg, Germany) using a 14-mm diameter blowpipe (Telinject ® , Römerberg, Germany) [ 22 ]. Juvenile animals (<12 months) were manually restrained. Fecal samples were collected from all animals, either manually per rectum or postmortem when no feces could be obtained per rectum during live animal handling. Volatile organic compounds were collected from the VOC headspace formed by approximately 5 g of a fecal sample inside a 125-mL glass jar, as described by Nol et al. [ 9 ], via a vacuum pump (AirChek XR5000, SKC Inc., Eighty-Four, PA, USA) into a glass cartridge containing sorbent material suitable for VOC preconcentration and storing (Tenax TA, Sigma Aldrich, St. Louis, MO, USA). The samples were stored at 4 ◦C before analysis. Once the fecal samples were collected, the animals were euthanized via captive bolt and exsanguination as part of Doñana National Park population control and healthmonitoring program. The wild boars were necropsied, and blood, lung lobes, lymph nodes, and any other tissue displaying lesions compatible with M. bovis infection were cultured and analyzed for identification of M. bovis, as described by Nol et al. [ 9 ] and Safianowska et al. [24]. Full characterization of the animals included in this study and number of fecal VOC samples analyzed per animal are presented in Table 1. Animal grouping on age, disease, sex, and location is summarized in Table 2. Table 1. Information about animals and samples analyzed in this study. Animal No. M. bovis Infection Sex Age 1Location Number of Samples 2 1 Positive Male Adult Martinazo 2 2 Negative Male Juvenile Santa Olalla 2 3 Positive Male Juvenile Palacio 2 4 Positive Male Juvenile Palacio 2 5 Positive Female Adult Palacio 2 6 Positive Female Sub-adult Palacio 2 7 Negative Male Sub-adult Santa Olalla 2 8 Negative Female Sub-adult Santa Olalla 2 9 Positive Male Adult Santa Olalla 2 10 Negative Male Juvenile Santa Olalla 2 11 Negative Female Adult Santa Olalla 2 12 Positive Male Adult Santa Olalla 2 13 Negative Male Adult Santa Olalla 2 14 Negative Female Adult Martinazo 2 15 Positive Female Juvenile Martinazo 2 16 Negative Male Juvenile Martinazo 2 17 Positive Male Sub-adult Martinazo 2 18 Positive Male Sub-adult Martinazo 2 19 Negative Female Juvenile Palacio 2 20 Negative Female Juvenile Palacio 2 Sensors 2021,21, 584 4 of 14 Table 1. Cont. Animal No. M. bovis Infection Sex Age 1Location Number of Samples 2 21 Negative Female Juvenile Martinazo 2 22 Negative Female Juvenile Santa Olalla 2 23 Negative Female Adult Santa Olalla 2 24 Negative Female Juvenile Santa Olalla 2 25 Positive Female Juvenile Martinazo 2 26 Positive Male Juvenile Martinazo 2 27 Positive Female Juvenile Martinazo 2 28 Positive Female Juvenile Martinazo 1 29 Positive Male Adult Santa Olalla 1 30 Positive Female Adult Santa Olalla 1 31 Positive Male Juvenile Martinazo 2 32 Negative Female Adult Martinazo 1 33 Negative Male Adult Santa Olalla 2 34 Positive Male Sub-adult Santa Olalla 2 35 Negative Female Juvenile Santa Olalla 2 36 Negative Male Juvenile Fuente del Duque 1 37 Negative Female Sub-adult Martinazo 1 1 Adult: >24 months, Subadult: 12–24 months, Juvenile: <12 months. 2 The second VOC sample was collected from the same fecal sample introduced in the same jar, immediately after the collection of the first sample. In some cases, one of the samples was damaged during transport and/or handling. Therefore, for some animals, only one sample was available for the analysis. Table 2. Animal grouping on age, disease, sex, and location. Age Location bTB Negative bTB Positive Male Female Male Female Adult Santa Olalla 2 2 3 1 Martinazo - 2 1 - Palacio - - - 1 Total 2 4 4 2 Sub-adult Santa Olalla 1 1 1 - Martinazo - 1 2 - Palacio - - - 1 Total 1 2 3 1 Juvenile Santa Olalla 2 3 - - Martinazo 1 1 2 4 Palacio - 2 2 - Fuente del Duque 1 - - - Total 4 6 4 4 2.2. Electronic Nose and Sensing Measurements The electronic nose employed in this study consisted of 10 chemical gas sensors based on monolayers of ultrapure organically-functionalized gold nanoparticles fabricated employing the Advanced Gas Deposition (AGD) technique, as described in Welearegay et al. [ 25 ]. The sensors were fabricated on 13 × 8 mm 2 one-side polished p-type silicon substrates provided with two parallel gold electrodes on their polished side, forming a 15- µ m-gap active area region, where the sensing material was deposited. The characteristics of the sensors with different organic functionalities are presented in Table 3. Differences in their resistance are due to variations of the Au nanoparticle assembly structure and conductivity of the cross-linked functional organic groups attached to the Au nanoparticles. For the sake of exemplification, two sensing nanomaterials are presented in Figure 1. Sensors 2021,21, 584 5 of 14 Table 3. Information about the sensors employed in this study. Sensor No. Organic Functionality Electrical Resistance S1 2-Mercaptobenzoxazole 347 kΩ S2 Methyl-3- mercaptopropionate 253 kΩ S3 1-Decanethiol 506 kΩ S4 1-Decanethiol 641 kΩ S5 2-Mercaptobenzoxazole 1.5 kΩ S6 11-Mercaptoundecanoic acid 1.6 kΩ S7 4-Methoxy-α-toluenethiol 11 kΩ S8 4-Methoxy-α-toluenethiol 6.8 MΩ S9 1-Butanethiol 759 kΩ S10 Octadecylamine 6.2 MΩ Sensors 2021, 21, x FOR PEER REVIEW 5 of 14 Sensors 2021, 21, x. https://doi.org/10.3390/xxxxx www.mdpi.com/journal/sensors resistance are due to variations of the Au nanoparticle assembly structure and conductivity of the cross-linked functional organic groups attached to the Au nanoparticles. For the sake of exemplification, two sensing nanomaterials are presented in Figure 1. (a) (b) Figure 1. Surface Electron Microscopy (SEM) images of gold nanoparticles functionalized with: (a) 2-Mercaptobenzoxazole and (b) 4-Methoxy-α-toluenethiol. Table 3. Information about the sensors employed in this study. Sensor No. Organic Functionality Electrical Resistance S1 2-Mercaptobenzoxazole 347 kΩ S2 Methyl-3-mercaptopropionate 253 kΩ S3 1-Decanethiol 506 kΩ S4 1-Decanethiol 641 kΩ S5 2-Mercaptobenzoxazole 1.5 kΩ S6 11-Mercaptoundecanoic acid 1.6 kΩ S7 4-Methoxy-α-toluenethiol 11 kΩ S8 4-Methoxy-α-toluenethiol 6.8 MΩ S9 1-Butanethiol 759 kΩ S10 Octadecylamine 6.2 MΩ The setup employed for performing the measurement of the fecal VOC samples with the electronic nose system is shown in Figure 2. The sensors were placed inside a 26-cm3 inner volume Teflon test chamber provided with two openings for the sample inlet and sample outlet, respectively (Figure 2a(E),b). The Tenax TA sorbent tube storing the fecal VOC sample (Figure 2a(G)) was heated at 250 °C for 5 min inside a home-built temperature-controlled thermal desorption unit (Figure 2a(D),c) to desorb the VOCs from the Tenax TA matrix. Sample measurements comprised the following cycles. (i) 5 min of continuous N2 flow (delivered from a commercial N2 gas bottle, Cryogas S.A., Colombia—Figure 2a(F)) passed at 5 L/min flow rate through the sensor test chamber for purging purposes before the sample measurement, (ii) 5 min of exposure to the fecal VOCs carried by continuous N2 flow that passed at 100 mL/min flow rate at first through the thermal desorption unit for taking the thermally released VOCs (see Figure 2c) and then through the sensor test chamber together with the fecal VOCs, (iii) 5 min of continuous N2 flow passed at 5 L/min flow rate through the sensor test chamber for purging purposes after the sample measurement. Figure 1. Surface Electron Microscopy (SEM) images of gold nanoparticles functionalized with: ( a ) 2-Mercaptobenzoxazole and (b) 4-Methoxy-α-toluenethiol. The setup employed for performing the measurement of the fecal VOC samples with the electronic nose system is shown in Figure 2. The sensors were placed inside a 26-cm 3 inner volume Teflon test chamber provided with two openings for the sample inlet and sample outlet, respectively (Figure 2a(E),b). The Tenax TA sorbent tube storing the fecal VOC sample (Figure 2a(G)) was heated at 250 ◦ C for 5 min inside a home-built temperaturecontrolled thermal desorption unit (Figure 2a(D),c) to desorb the VOCs from the Tenax TA matrix. Sample measurements comprised the following cycles. (i) 5 min of continuous N 2 flow (delivered from a commercial N 2 gas bottle, Cryogas S.A., Colombia—Figure 2a(F)) passed at 5 L/min flow rate through the sensor test chamber for purging purposes before the sample measurement, (ii) 5 min of exposure to the fecal VOCs carried by continuous N 2 flow that passed at 100 mL/min flow rate at first through the thermal desorption unit for taking the thermally released VOCs (see Figure 2c) and then through the sensor test chamber together with the fecal VOCs, (iii) 5 min of continuous N 2 flow passed at 5 L/min flow rate through the sensor test chamber for purging purposes after the sample measurement. Sensors 2021,21, 584 6 of 14 Sensors 2021, 21, x FOR PEER REVIEW 6 of 14 Sensors 2021, 21, x. https://doi.org/10.3390/xxxxx www.mdpi.com/journal/sensors During the entire measurement process, the sensors were successively operated at 8 V for 10 s in a switching mode. Thus, during the operation period of one of the sensors, the other ones remained inactive by not supplying an operation voltage to them. Therefore, all sensors were once active every 100 s, implying 30 s of operation of each sensor during the 5 min duration of each measurement cycle. A high precision power source (B2902A, Keysight Technologies, Hungary—Figure 2a(C)) controlled the sensor supply, as well as the thermal desorption unit. The dc current through each sensor during each operation period was acquired at nine samples/s acquisition rate employing a high resolution data acquisition system (34992A LXI/Data Acquisition Keysight Technolgies, Hungary—Figure 2a(B)) and stored in a computer (Figure 2a(A)) for further analysis. The measurement process consisted of three complete operation periods per sensor for each 5-min measurement cycle (see Figure 3). (a) (b) (c) Figure 2. (a) Measurement setup: A—computer, B—data acquisition system, C—power source, D—thermal desorption unit, E—sensor test chamber, F—N 2 gas bottle, and G—Tenax TA storage tube. (b) Inner view of the sensor test chamber with the chemical gas sensors. (c) Schematic representation of the thermal desorption unit, illustrating released fecal VOCs transported by the N 2 gas flow. Figure 2. ( a ) Measurement setup: A—computer, B—data acquisition system, C—power source, D—thermal desorption unit, E—sensor test chamber, F—N 2 gas bottle, and G—Tenax TA storage tube. ( b ) Inner view of the sensor test chamber with the chemical gas sensors. ( c ) Schematic representation of the thermal desorption unit, illustrating released fecal VOCs transported by the N2gas flow. During the entire measurement process, the sensors were successively operated at 8 V for 10 s in a switching mode. Thus, during the operation period of one of the sensors, the other ones remained inactive by not supplying an operation voltage to them. Therefore, all sensors were once active every 100 s, implying 30 s of operation of each sensor during the 5 min duration of each measurement cycle. A high precision power source (B2902A, Keysight Technologies, Hungary— Figure 2a(C) ) controlled the sensor supply, as well as the thermal desorption unit. The dc current through each sensor during each operation period was acquired at nine samples/s acquisition rate employing a high resolution data acquisition system (34992A LXI/Data Acquisition Keysight Technolgies, Hungary—Figure 2a(B)) and stored in a computer ( Figure 2a(A) ) for further analysis. The measurement process consisted of three complete operation periods per sensor for each 5-min measurement cycle (see Figure 3). Sensors 2021,21, 584 7 of 14 Sensors 2021, 21, x FOR PEER REVIEW 7 of 14 Sensors 2021, 21, x. https://doi.org/10.3390/xxxxx www.mdpi.com/journal/sensors (a) (b) (c) (d) Figure 3. Sensor response (current) as a function of sampling time showing all measurement cycles of the sensors that responded to the fecal VOC samples, when the electronic nose was exposed to one of the samples from wild boar #2 (see Table 1): (a) Sensor S5, (b) Sensor S6, (c) Sensor S8, and (d) Sensor S9. Sensor details are found in Table 3. 2.3. Data Analysis A 20-point moving average filter was applied to the acquired sensor signals in order to reduce the noise generated by the electronic devices. Three features were extracted on the filtered signals from sensor responses to each sample analyzed (see Figure 4b). • F1: A 1 /A 0 , where A 1 is the area under the curve calculated from the first 70 data points of the filtered signal for the first operation period of the sensor exposure to the fecal VOC sample, and A 0 is the area under the curve calculated from the first 70 data points of the filtered signal obtained in the last operation period of the same sensor during the purging process immediately prior to sample exposure, • F2: (I m1 − I m0 )/I m0 , where I m1 is the averaged current calculated with the first 70 current values of the filtered signal for the first operation period of the sensor exposure to the fecal VOC sample, and I m0 is the average current calculated with the first 70 current values of the filtered signal obtained in the last operation period of the same sensor during the purging process immediately prior to sample exposure, • F3: (∆I 1 − ∆I 0 )/∆I 0 , where ∆I 1 = I f1 − I i1 and ∆I 0 = I f0 − I i0 , and where I f1 and I i1 are the 70th and 1st current values, respectively, of the filtered signal for the first operation period of the sensor exposure to the fecal VOC sample, and I f0 and I i0 are the 70th and 1st current values, respectively, of the filtered signal obtained in the last operation period of the same sensor during the purging process immediately prior to sample exposure. One of the two samples collected from each wild boar was employed for building classification models for bTB positive and bTB negative animals. The Discriminant Function Analysis (DFA) pattern recognition algorithm was used for this aim [26]. The analysis was separately performed for each age group of animals: adult, sub-adult, and juvenile. The selection of the most discriminative sensors and features for building the classification models for each age group was heuristically achieved by calculating the discrimination Figure 3. Sensor response (current) as a function of sampling time showing all measurement cycles of the sensors that responded to the fecal VOC samples, when the electronic nose was exposed to one of the samples from wild boar #2 (see Table 1): (a) Sensor S5, (b) Sensor S6, (c) Sensor S8, and (d) Sensor S9. Sensor details are found in Table 3. 2.3. Data Analysis A 20-point moving average filter was applied to the acquired sensor signals in order to reduce the noise generated by the electronic devices. Three features were extracted on the filtered signals from sensor responses to each sample analyzed (see Figure 4b). • F1: A 1 /A 0 , where A 1 is the area under the curve calculated from the first 70 data points of the filtered signal for the first operation period of the sensor exposure to the fecal VOC sample, and A 0 is the area under the curve calculated from the first 70 data points of the filtered signal obtained in the last operation period of the same sensor during the purging process immediately prior to sample exposure, • F2: (I m1 − I m0 )/I m0 , where I m1 is the averaged current calculated with the first 70 current values of the filtered signal for the first operation period of the sensor exposure to the fecal VOC sample, and I m0 is the average current calculated with the first 70 current values of the filtered signal obtained in the last operation period of the same sensor during the purging process immediately prior to sample exposure, • F3: ( ∆ I 1−∆ I 0 )/ ∆ I 0 , where ∆ I 1 = I f1 − I i1 and ∆ I 0 = I f0 − I i0 , and where I f1 and I i1 are the 70th and 1st current values, respectively, of the filtered signal for the first operation period of the sensor exposure to the fecal VOC sample, and I f0 and I i0 are the 70th and 1st current values, respectively, of the filtered signal obtained in the last operation period of the same sensor during the purging process immediately prior to sample exposure. Sensors 2021,21, 584 8 of 14 Sensors 2021, 21, x FOR PEER REVIEW 8 of 14 Sensors 2021, 21, x. https://doi.org/10.3390/xxxxx www.mdpi.com/journal/sensors accuracy of the models through leave-one-out cross-validation, which is an error estimation that was extensively employed in the literature when analyzing small sample biological datasets [27]. Only the sensors that responded to the fecal VOC samples (see the Results section) were considered for building the classification models. All possible combinations of at least two features extracted from these sensors were assessed, and those that achieved the best classification result for each age group were finally selected. The discrimination potential of the models built was verified by assessing the classification accuracy of the second sample of those animals for which two samples were available (see Table 1). (a) (b) Figure 4. (a) Exposure of sensor S9 to the fecal VOC samples of a bTB negative wild boar (blue curve—boar #2 in Table 1) and a bTB positive wild boar (red curve—boar #12 in Table 1). (b) Parameters used to calculate sensor response features, indicated on the filtered signal of sensor S9 to the fecal VOC sample of wild boar #12. Sensor details are found in Table 3. 3. Results 3.1. Sensor Responses Four sensors from the electronic nose employed in this study responded to the fecal VOC samples analyzed. These sensors were S5, S6, S8, and S9 (see Table 3 for details), and their characteristic responses to a representative VOC sample are presented in Figure 3. Only the three operation periods in the active mode of the sensors, acquired during each measurement cycle, are indicated in this figure (initial purging process (first three operation periods), sample exposure (next three operation periods), and purging process after a sample measurement (last three operation periods)). Current modulation during the 90 data points acquired during every operation period of a sensor can be clearly observed in this figure. Sensors’ exposure to the fecal VOC samples of bTB positive and bTB negative boar revealed slightly different response patterns, as visible in Figure 4a. In general, a good repeatability between the three operation periods of the same measurement cycle was observed for all sensors and samples analyzed, as denoted by sensors’ responses presented in Figures 3 and 4. However, in some cases, a drift was noticed during the three operation periods of sample exposure, as it was the case presented in Figure 3d. For this reason, only the first operation period of the sensors acquired during sample exposure and the last operation period acquired during the purging process immediately prior to sample exposure were considered for feature extraction. The parameters used to calculate sensor response features are presented in Figure 4b. 3.2. Classification Results During the training phase, classification models were separately built for each age group of animals with one sample acquired from each animal. The classification models obtained are presented in Figure 5 (left panels), while the sensors and features used to build each one of the models are presented in Table 4. Leave-one-out cross-validation of 0 102030405060708090 Time (s) 0 0.5 1 1.5 2 2.5 S9 bTB negative bTB positive Sample exposure Purging Purging 0 102030405060708090 Time (s) 0.5 1 1.5 2 S9 A0 Ii0 A1 Im1 If1 Ii1 If0 Im0 Figure 4. ( a ) Exposure of sensor S9 to the fecal VOC samples of a bTB negative wild boar (blue curve—boar #2 in Table 1) and a bTB positive wild boar (red curve—boar #12 in Table 1). ( b ) Parameters used to calculate sensor response features, indicated on the filtered signal of sensor S9 to the fecal VOC sample of wild boar #12. Sensor details are found in Table 3. One of the two samples collected from each wild boar was employed for building classification models for bTB positive and bTB negative animals. The Discriminant Function Analysis (DFA) pattern recognition algorithm was used for this aim [ 26 ]. The analysis was separately performed for each age group of animals: adult, sub-adult, and juvenile. The selection of the most discriminative sensors and features for building the classification models for each age group was heuristically achieved by calculating the discrimination accuracy of the models through leave-one-out cross-validation, which is an error estimation that was extensively employed in the literature when analyzing small sample biological datasets [ 27 ]. Only the sensors that responded to the fecal VOC samples (see the Results section) were considered for building the classification models. All possible combinations of at least two features extracted from these sensors were assessed, and those that achieved the best classification result for each age group were finally selected. The discrimination potential of the models built was verified by assessing the classification accuracy of the second sample of those animals for which two samples were available (see Table 1). 3. Results 3.1. Sensor Responses Four sensors from the electronic nose employed in this study responded to the fecal VOC samples analyzed. These sensors were S5, S6, S8, and S9 (see Table 3for details), and their characteristic responses to a representative VOC sample are presented in Figure 3 . Only the three operation periods in the active mode of the sensors, acquired during each measurement cycle, are indicated in this figure (initial purging process (first three operation periods), sample exposure (next three operation periods), and purging process after a sample measurement (last three operation periods)). Current modulation during the 90 data points acquired during every operation period of a sensor can be clearly observed in this figure. Sensors’ exposure to the fecal VOC samples of bTB positive and bTB negative boar revealed slightly different response patterns, as visible in Figure 4a. In general, a good repeatability between the three operation periods of the same measurement cycle was observed for all sensors and samples analyzed, as denoted by sensors’ responses presented in Figures 3and 4. However, in some cases, a drift was noticed during the three operation periods of sample exposure, as it was the case presented in Figure 3d. For this reason, only the first operation period of the sensors acquired during sample exposure and the last operation period acquired during the purging process immediately prior to sample exposure were considered for feature extraction. The parameters used to calculate sensor response features are presented in Figure 4b. Sensors 2021,21, 584 9 of 14 3.2. Classification Results During the training phase, classification models were separately built for each age group of animals with one sample acquired from each animal. The classification models obtained are presented in Figure 5(left panels), while the sensors and features used to build each one of the models are presented in Table 4. Leave-one-out cross-validation of these models provided 100% accuracy, 100% sensitivity, and 100% specificity in the case of the adult and sub-adult animals, and 88.9% accuracy, 75% sensitivity, and 100% specificity in the case of the juvenile animals. Sensors 2021, 21, x FOR PEER REVIEW 9 of 14 Sensors 2021, 21, x. https://doi.org/10.3390/xxxxx www.mdpi.com/journal/sensors these models provided 100% accuracy, 100% sensitivity, and 100% specificity in the case of the adult and sub-adult animals, and 88.9% accuracy, 75% sensitivity, and 100% specificity in the case of the juvenile animals. (a) (d) (b) (e) (c) (f) Figure 5. Classification models built for: (a) adult animals, (b) sub-adult animals, and (c) juvenile animals. Projection of the test samples on the classification models for: (d) adult animals, (e) sub-adult animals, and (f) juvenile animals. CV1 and CV2: canonical variables of the DFA model, calculated as a linear combination of sensor features, as described in Ionescu et al. [26]. Legend: control—bTB negative animals, target—bTB positive animals, filled symbols—samples used in the training phase, and empty symbols—samples used in the testing phase. Figure 5. Classification models built for: ( a ) adult animals, ( b ) sub-adult animals, and ( c ) juvenile animals. Projection of the test samples on the classification models for: ( d ) adult animals, ( e ) sub-adult animals, and ( f ) juvenile animals. CV1 and CV2: canonical variables of the DFA model, calculated as a linear combination of sensor features, as described in Ionescu et al. [ 26 ]. Legend: control—bTB negative animals, target—bTB positive animals, filled symbols—samples used in the training phase, and empty symbols—samples used in the testing phase.