1 Parameter-dependent behavior of articular cartilage: 3D mechano-electrochemical computational model Sara Manzano1,2,3, Manuel Doblaré1,2,3 and Mohamed Hamdy Doweidar1,2,3* 1Group of Structural Mechanics and Materials Modelling (GEMM), Aragón Institute of Engineering Research (I3A), University of Zaragoza, Spain. 2Mechanical Engineering Department, School of Engineering and Architecture (EINA), University of Zaragoza, Spain. 3Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER -BBN), Spain. Corresponding author: *Mohamed Hamdy Doweidar Email:
[email protected] Mechanical Engineering Department, School of Engineering and Architecture (EINA), University of Zaragoza, María de Luna s/n, Betancourt Building, 50018 Zaragoza, SPAIN. Phone: +34 876555210
2 Abstract Background and Objective: Changes in mechano-electrochemical properties of articular cartilage play an essential role in the majority of cartilage diseases. Despite of this importance, the specific effect of each parameter into tissue behavior remains still obscure. Parametric computational modeling of cartilage can provide some insights into this matter, specifically the study of mechano-electrochemical properties variation and their correlation with tissue swelling, water and ion fluxes. Thus, the aim of this study is to evaluate the influence of the main mechanical and electrochemical parameters on the determination of articular cartilage behavior by a parametric analysis through a 3D finite element model. Methods: For this purpose, a previous 3D mechano-electrochemical model, developed by the same authors, of articular cartilage behavior has been used. Young´s modulus, Poisson coefficient, ion diffusivities and ion activity coefficients variations have been analyzed and quantified through monitoring tissue simulated response. Results: Simulation results show how Young´s modulus and Poisson coefficient control tissue behavior rather than electrochemical properties. Meanwhile, ion diffusivity and ion activity coefficients appear to be vital in controlling velocity of incoming and outgoing fluxes. Conclusions: This parametric study establishes a basic guide when defining the main properties that are essential to be included into computational modeling of articular cartilage providing a helpful tool in tissue simulations. Keywords: Parametric analysis, articular cartilage, mechano-electrochemical model, cartilage Young´s modulus, ion diffusivity, ion activity coefficient.
3 1 Introduction Articular cartilage plays a vital role in the function of diarthrodial joints (Boschetti et al. 2004). The initial event that triggers pathological process of cartilage degeneration is still unknown (Wilson et al. 2005). Hence, to investigate the initiation of cartilage diseases, most important parameters that control its behavior should be determined. So far, the common method to accomplish that, are specific experimental assays (Pearle et al. 2005; Albro et al. 2009; Virén et al. 2009). However, these techniques require high costs and elevate time consuming. Besides, experimental approaches limit the study of parameters in an individual manner. To solve these problems, in the last decade, it has emerged the use of computational models to simulate cartilage behaviour (Landinez-Parra et al. 2011; Seifzadeh et al. 2012) as well as materials mimicking cartilage (Manzano et al. 2014; Krishnan Namboori et al. 2013). Therein, the finite element method is the most used (Soulhat et al. 1999; Smith et al., 2013). In the literature many material models for articular cartilage can be found. These models range from relatively simple, including the biphasic nature of the tissue (Higginson et al., 1976; Chen et al. 1997), to models that include descriptions of all major individual components of the cartilage (Mow and Guo 2002; Ateshian et al. 2013; Manzano et al. 2014a; Manzano et al. 2014b; Sun et al. 2004). However, the main parameters to consider in these simulations remain still obscure since the requirements of a material model are highly dependent on the particular question under research. In general, the more features of the composition and structure of articular cartilage are included, the larger the number of material parameters that must be determined, and the more computationally expensive the model becomes. Hence, we should always try to use
4 the simplest model with the lowest number of tissue properties to obtain the required data but without compromising the predictive capacity of the computational model. The present parametric study faces important questions like: i) is the weakening of collagen matrix enough for tissue to swell or it is required to consider the proteoglycans content decrement?; ii) is Poisson coefficient an essential parameter in articular cartilage modeling?; iii) which phenomena, mechanical, chemical or electrical do manage tissue behavior?; (iv) are they combined to control tissue behavior or one of them is more relevant? To solve these questions a previous developed three-dimensional mechanoelectrochemical model (Manzano et al. 2014a; Manzano et al. 2014 b) has been used to analyze and quantify the influence of each parameter variation into cartilage behavior. Specifically, Young´s modulus (E ), Poisson coefficient (ν), cation and anion diffusivities (D+ and D- respectively), cation and anion activity coefficient (γ+ and γrespectively) changes have been addressed. To our knowledge, this is the first parametric study that determines the influence of these properties in an isolate manner in cartilage behavior, resulting in a basic guide to select the main parameters required for articular cartilage simulation. Note that the model includes essential biological phenomena, previously described in literature, that affect cartilage behaviour (diffusive-convective events and mechano-electrochemical effects) (Mow and Guo, 2002; Sun et al., 1999; Lai et al., 1991). However, it excludes those that experimentally show less influence as the viscosity of the solid matrix. Often, material models of articular cartilage exclude this effect since in short-term type of simulation the viscosity does not play a great role and articular cartilage appears as an elastic
5 solid with lower compressibility (Argatov and Mishuris 2015; Julkunen et al., 2013). Results show that (i) only collagen degradation is required to promote tissue swelling; (ii) minimal variation in ν generates significant differences in tissue swelling and water and anion fluxes; (iii) variation in D+ and D- seems to have less influence in capturing cartilage behavior than the mechanical parameters, however, they control the velocity of ion fluxes and finally, (iv) similar to D+ and D- , γ+ and γshow lower influence into tissue deformation (one order or magnitude less) than the studied mechanical properties. The presented parametric study is a helpful tool to decipher the effects on cartilage simulated behaviour when varying Young´s modulus, Poisson coefficient, and ion activity and diffusivity coefficients. Besides, the inclusion of repulsion phenomenon due to negative fixed charges attached to proteoglycans and the 3D nature of the model, present this algorithm as a new and easy method for the analysis and selection of the main parameters to include in cartilage computational models. 2 Material and methods Based on our previous work (Manzano et al. 2014a) four phases are considered: negatively charged porous-elastic solid (s), fluid (f), cations (+) and anions (-). These phases dynamically interact with each other triggering essential mechanoelectrochemical phenomena for cartilage maintenance (for more details see (Sun et al. 2004; Manzano et al. 2014a; Manzano et al. 2014b)).
6 2.1 Mechano-electrochemical model 2.1.1 Governing equations The governing equations of the model are based in the momentum and mass balance for the whole mixture and the charge balance for each ion. The relation between the four basic unknowns (us the displacement of the solid matrix, 𝜀𝜀𝑤𝑤 the chemical potential of water, 𝜀𝜀+ and 𝜀𝜀− the electrochemical potentials for cations and anions respectively) are summarized below, Momentum balance equation for the whole mixture ∇·𝛔𝛔⏟ 𝛔𝛔𝑓𝑓+𝛔𝛔𝑐𝑐+𝛔𝛔𝑠𝑠=𝟎𝟎. (1) Mass balance equation for the whole mixture ∇·𝐯𝐯𝑠𝑠+∇·𝐉𝐉𝑤𝑤= 0. ( 2) Charge balance equation for each studied ion 𝜕𝜕(𝛷𝛷𝑤𝑤𝑐𝑐+) 𝜕𝜕𝜕𝜕 +∇·𝐉𝐉+ ⏟ 𝑑𝑑𝑑𝑑𝑑𝑑𝑑𝑑𝑑𝑑𝑠𝑠𝑑𝑑𝑑𝑑𝑑𝑑 +∇·(𝛷𝛷𝑤𝑤𝑐𝑐+𝐯𝐯𝑠𝑠) � � � � � � � 𝑐𝑐𝑑𝑑𝑑𝑑𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑑𝑑𝑑𝑑𝑑𝑑 = 0, ( 3) 𝜕𝜕(𝛷𝛷𝑤𝑤𝑐𝑐−) 𝜕𝜕𝜕𝜕 +∇·𝐉𝐉− ⏟ 𝑑𝑑𝑑𝑑𝑑𝑑𝑑𝑑𝑑𝑑𝑠𝑠𝑑𝑑𝑑𝑑𝑑𝑑 +∇·(𝛷𝛷𝑤𝑤𝑐𝑐−𝐯𝐯𝑠𝑠) � � � � � � � 𝑐𝑐𝑑𝑑𝑑𝑑𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑑𝑑𝑑𝑑𝑑𝑑 = 0. ( 4) In these equations, σ corresponds to the stress tensor related to the total mixture while and 𝛔𝛔𝑑𝑑 , 𝛔𝛔𝑐𝑐 and 𝛔𝛔𝑠𝑠 are the stress tensors of the fluid, chemical and solid phases respectively. 𝐯𝐯𝑠𝑠=𝜕𝜕𝐮𝐮𝑠𝑠 𝜕𝜕𝑐𝑐 refers to the velocity of the solid matrix. Note that in equation 1, body and inertial forces are neglected. Moreover, small strain formulation is adopted. Besides, 𝑐𝑐+ and 𝑐𝑐− are cation and anion concentrations respectively. Finally, 𝛷𝛷𝑤𝑤 corresponds to the porosity of the tissue (Sun et al. 2004). Regarding the different
7 fluxes, the water flux, 𝐉𝐉𝑤𝑤, cation flux, 𝐉𝐉+ , and anion flux, 𝐉𝐉−, can be written as a combination of the electrochemical potentials, 𝐉𝐉𝑤𝑤=−𝑅𝑅 𝑇𝑇𝛷𝛷𝑤𝑤 𝛼𝛼�∇𝜀𝜀𝑤𝑤+𝑐𝑐+ 𝜀𝜀+∇𝜀𝜀++𝑐𝑐− 𝜀𝜀−∇𝜀𝜀−�, ( 5) 𝐉𝐉+=−𝑅𝑅 𝑇𝑇𝛷𝛷𝑤𝑤𝑐𝑐+ 𝛼𝛼∇𝜀𝜀𝑤𝑤−�𝛷𝛷𝑤𝑤𝑐𝑐+𝐷𝐷+ 𝜀𝜀++𝑅𝑅 𝑇𝑇𝛷𝛷𝑤𝑤(𝑐𝑐+)2 𝛼𝛼𝜀𝜀+�∇𝜀𝜀+−𝑅𝑅 𝑇𝑇𝛷𝛷𝑤𝑤𝑐𝑐+𝑐𝑐− 𝛼𝛼𝜀𝜀+∇𝜀𝜀−, ( 6) 𝐉𝐉−=−𝑅𝑅 𝑇𝑇𝛷𝛷𝑤𝑤𝑐𝑐− 𝛼𝛼∇𝜀𝜀𝑤𝑤−�𝛷𝛷𝑤𝑤𝑐𝑐−𝐷𝐷− 𝜀𝜀−+𝑅𝑅 𝑇𝑇𝛷𝛷𝑤𝑤(𝑐𝑐−)2 𝛼𝛼𝜀𝜀−�∇𝜀𝜀−−𝑅𝑅 𝑇𝑇𝛷𝛷𝑤𝑤𝑐𝑐+𝑐𝑐− 𝛼𝛼𝜀𝜀+∇𝜀𝜀+, ( 7) Here, α refers to the drag coefficient between the solid and the water phases. Atmospheric conditions are assumed where R is the universal gas constant and T is the absolute temperature (Garcia and Cortes 2006). The corresponding constitutive equations associated to the state variables, referring to equations 1-7, are also given by, 𝛔𝛔=−𝑃𝑃𝐈𝐈� 𝛔𝛔 𝑓𝑓 � 𝑜𝑜𝑠𝑠𝑜𝑜𝑜𝑜𝑜𝑜𝑜𝑜𝑐𝑐 𝑝𝑝𝑝𝑝𝑝𝑝𝑠𝑠𝑠𝑠𝑝𝑝𝑝𝑝𝑝𝑝 −𝑇𝑇𝑐𝑐𝐈𝐈 � 𝛔𝛔 𝑐𝑐 � 𝑃𝑃𝑃𝑃𝑠𝑠 𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑝𝑟𝑟𝑠𝑠𝑜𝑜𝑜𝑜𝑟𝑟 +𝜆𝜆𝑠𝑠𝜃𝜃𝐈𝐈+ 2µ𝑠𝑠𝛜𝛜 � � � � � � � � � , 𝛔𝛔 𝑠𝑠 � 𝑝𝑝𝑟𝑟𝑙𝑙𝑠𝑠𝑜𝑜𝑜𝑜𝑐𝑐 𝑠𝑠𝑜𝑜𝑝𝑝𝑝𝑝𝑠𝑠𝑠𝑠 (8) 𝜀𝜀𝑤𝑤=𝑃𝑃 𝑅𝑅 𝑇𝑇−𝛷𝛷(𝑐𝑐++𝑐𝑐−)+𝐵𝐵𝑤𝑤 𝑅𝑅 𝑇𝑇𝜃𝜃, (9) 𝜀𝜀+=𝛾𝛾+𝑐𝑐+𝑒𝑒𝑒𝑒𝑝𝑝�𝐹𝐹𝑐𝑐𝜓𝜓 𝑅𝑅 𝑇𝑇�, (10) 𝜀𝜀−=𝛾𝛾−𝑐𝑐−𝑒𝑒𝑒𝑒𝑝𝑝�−𝐹𝐹𝑐𝑐𝜓𝜓 𝑅𝑅 𝑇𝑇�, (11) where 𝜓𝜓 is the electrical potential, 𝐵𝐵𝑤𝑤 is the fluid-solid coupling coefficient, 𝐹𝐹𝑐𝑐 is the Faraday constant, 𝛷𝛷 is the osmotic coefficient, and 𝐈𝐈 is the identity tensor. Here, P
8 refers to the fluid pressure, 𝜃𝜃=𝑑𝑑𝑑𝑑𝑑𝑑 𝐮𝐮𝐬𝐬 corresponds to the solid matrix dilatation related to the infinitesimal strain tensor of the solid matrix, 𝛜𝛜 is the solid matrix deformation, and finally, 𝜆𝜆𝑠𝑠 and µ𝑠𝑠 are the Lame constants (Garcia and Cortes 2006). The chemical expansion due to proteoglycan repulsion phenomenon, 𝑇𝑇𝐶𝐶, is considered into the computational model though the following constitutive equation. 𝑇𝑇𝐶𝐶=𝑎𝑎0𝑐𝑐𝐹𝐹𝑒𝑒𝑒𝑒𝑝𝑝�−𝑘𝑘 𝛾𝛾∓ 𝛾𝛾∓∗��𝑐𝑐(𝑐𝑐+𝑐𝑐𝐹𝐹). Here, where 𝑎𝑎0 and 𝑘𝑘 are the proteoglycan repulsion coefficients. 𝛾𝛾∓ and 𝛾𝛾∓∗ are the mean activity coefficient of ions along the process and in the reference state, respectively. 𝑐𝑐 refers to the neutral external salt concentration (Manzano et al. 2014b; Lai et al. 1991). Tissue anisotropy has been mathematically incorporated though the depth-dependent distribution of fixed charges attached to proteoglycans, porosity and ion concentrations within the tissue (Manzano et al. 2014a; Manzano et al. 2014b). 2.1.2 Numerical implementation Three-linear 8-noded hexahedral elements with 2×2×2 Gaussian integration points are used. The selected average mesh results in a total of 1680 elements. The highly nonlinear finite element formulation has been implemented in a user defined element subroutine of the commercial software package Abaqus 6.11. A detailed description of the discretization developed for the formulation is collected in the previous work (Manzano et al. 2014a).
9 2.2 Numerical application The geometry reproduced as well as the experimental procedure corresponds to those assays described by Lai et al. (1991). Therefore, this experimental situation is computationally reproduced to analyze and monitor the effect of mechanoelectrochemical parameters in cartilage behavior (Figure 1). Dimensions of cartilage specimen correspond to 1.5 mm diameter and 0.5 mm depth and the sample is fixed in a confining ring where the z-displacement of the sample is free. Under these conditions, external bath solution is modified from 0.15 M to 0.125 M to reach similar cartilage swelling observed in physiological conditions. No loads are applied onto the sample in z-direction. The ranges of the studied parameters variation are, Young´s modulus (from 0.35 to 1 MPa), Poisson coefficient (from 0.12 to 0.36), ion diffusivities (0.79·10-9 to 1.65·10-9 m2/s) and/or ion activity coefficients (from 0.527 to 0.72), while the rest of model parameters included into the computational model are fixed (Table 1). Accurate quantification of ion fluxes within the samples and motorization of tissue changes along the swelling processes are obtained.
16 (b) Figure 2: (a) Surface displacement obtained with the 3D computational model as function of the tissue Young´s modulus (E). The rest of model´s parameters are included in Table 1. (b) Z-displacement (uz), water (Jw), cation (J+) and ion (J-) fluxes obtained with the 3D computational model during 90 seconds of simulated time for E = 0.6 MPa and E = 1.0 MPa. Note that negative fluxes for each studied species correspond to the emergence of that component from the sample to the external bath. Conversely, positive fluxes refer to the entrance of the different components (water or ions) into the sample (tissue gain of material). Rest of parameters included in Table 1.
17 3.1.2 Effects of Poisson coefficient variation z-displacement To study ν the three most used values for articular cartilage modeling have been analyzed. For ν =0.36, simulation results showed a maximal z-displacement of 9.45·10-4 m. When, the value of this parameter is reduced to ν =0.28, the displacement reaches a maximum value of 3.04·10-4 m (Figure 3.a). Despite of expecting an increment of tissue swelling when decreasing ν, the difference between the three studied values show three orders of magnitude. Consistently, ν seems to represent, in combination with E, an essential parameter to include and thus, its accurate determination is essential to also obtain accurate results in simulation. Importantly, increment in ν is observed in osteoarthritic tissue even in the first stage of the disease (Pearle et al., 2005). Besides this increase in the tissue rigidity is also shown in aged articular cartilage (Bhosale et al., 2008). Water and ion fluxes Interestingly, water and ion fluxes showed even higher influence in morphological changes of the samples than E since they also control the stiffness of the tissue in an indirect manner. Thus, according to experimental measures, the physiological values commonly used in computational simulation of articular cartilages are ν = 0.28 and ν = 0.36. Both values have been considered in the present computational model resulting into significant differences in the simulated swelling process. For ν = 0.28 the incoming water flux goes from 5·10-8 m3/s (at the lower surface of the sample) to 6.37·10-7 m3/s (at the upper surface of the sample) (Figure 3.b). Note that, as explained before, these values are one order of magnitude higher than the water fluxes obtained with
18 previously studied E variation. Regarding ion fluxes, Figure 3.b shows how outgoing cation ranged from 1.80·10-5 mol/s to 5.46·10-5 mol/s while anion fluxes present a maximum of 1.87·10-5 mol/s at the upper surface and reduced to 4.43·10-5 mol/s at the bottom of the sample. In contrast, when ν is increased to 0.36, maximal water flux toward the external bath is reduced to 3.76·10-7 m3/s at the upper surface and the cation and anion fluxes exhibit a wide range from 1.80·10-5 mol/s to 1.28·10-4 mol/s. (a)
19 (b) Figure 3: (a) Surface displacement obtained with the 3D computational model as function of the tissue Poisson coefficient (ν). The rest of model parameters are included in Table 1. (b) Z-displacement (uz), water (Jw), cation (J+) and ion (J-) fluxes obtained with the 3D computational model during 90 seconds of simulated time for ν = 0.28 and ν = 0.36. Note that negative fluxes for each studied species correspond to the emergence of that component from the sample to the external bath. Conversely, positive fluxes refer to the entrance of the different components (water or ions) into the sample (tissue gain of material). Rest of parameters included in Table 1.
20 3.2 Analysis of the effect of the electrochemical parameters in the free cartilage swelling In this study, the model has been also applied to analyze the effect of the main electrochemical parameters that affect cartilage behavior such as ion diffusivities and ion activity coefficients, since cartilage maintenance is based in mediated diffusive processes controlled by these parameters. Simulation results show a lower influence of these coefficients in comparison with those related to mechanical properties of the articular cartilage. 3.2.1 Ion diffusivities Ion diffusivities control the flux velocity of cations and anions in the tissue when a gradient in ion concentrations is produced. As mentioned above, the external solution is diluted to 0.125 M NaCl which generates an imbalance between the inner and the outer medium of the sample. z-displacement Physically, to balance of difference in ion concentration created between inside and outside of the tissue, two flows appear: (i) water incoming flow that causes swelling of the sample and (ii) outgoing ion flows. When ion diffusivity is high, the increment of the velocity in outgoing flux of ions produces that these ions flow toward the external bath to equilibrate the concentration disbalance. Thus, water entrance to the sample is reduced. Figure 4.a shows this tendency. When D+ = D- = 0.79·10-9 m2/s, the maximal zdisplacement obtained is 1.99·10-6 m. When diffusivities are reduced, the model shows lower swelling of the sample reaching its minimum level at 7.08·10-10 m for D+ = D- =
21 1.34·10-9 m2/s. High values of ion diffusivity coefficients are related to different cartilage pathologies such as the osteoarthritis (Deng et al., 2007; Filidoro et al., 2005). Water and ion fluxes Again water, cation and anion fluxes at 90 s are shown again. Three-dimensional computational simulation results show the typical flux pattern exhibited in previous studies. Samples clearly highlights the upper as the one with higher outflow zone of cations with J+ = -7.83·10-5 mol/s and J- = -8.90·10-5 mol/s for anions when considering lower values of D+ = D- = 1.34·10-9 m2/s. When diffusivities are increased, simulations show how both cation and anion fluxes increase J+ = -1.78·10-5 mol/s and J- = -1.93·10-5 mol/s) while outflow of water is reduced in the upper surface (Figure 4.b). (a)
22 (b) Figure 4: (a) Surface displacement obtained with the 3D computational model as function of the tissue ion diffusivity coefficients (D+, D-). The rest of model parameters are included in Table 1. (b) Z- displacement (uz), water (Jw), cation (J+) and ion (J-) fluxes obtained with the 3D computational model during 90 seconds of simulated time for D+ = D- = 1.34·10-9 m2/s and D+ = D- = 1.44·10-9 m2/s. Note that negative fluxes for each studied species correspond to the emergence of that component from the sample to the external bath. Conversely, positive fluxes refer to the entrance of the different components (water or ions) into the sample (tissue gain of material). Rest of parameters included in Table 1.
23 3.2.2 Ion activity coefficients Finally, activity coefficients of cations and anions are also analyzed. Ion activity coefficients give a measure of the amount of ions that react in the solution. These parameters are of special interest in degenerative processes. Dai et al. in 1996 in their pioneer work demonstrated that in cartilage degenerative processes (Dai et al. 1996), where a sharp reduction of proteoglycans occurs and the subsequent decrement in fixed charge density, an increment in activity coefficient of ions was evidenced. Thus, in the present parametric study the effects of activities variation have been modelled to analyze its effect in articular cartilage behavior. Similar to ion diffusivity coefficients, high ion activity coefficients are commonly associated to cartilage pathologies such as osteoarthritis (Sun et al., 2004; Mow and Guo 2002; Sun et al., 1999). z-displacement Similar to diffusivity of ions, ion activity coefficients increase in case of cartilage degeneration. For high values of ion activity coefficients, the amount of ions that react inside the tissue is higher. Subsequently, the formation of salt generates higher disbalance between inside and outside the tissue. Then, the flux of water required to return the steady-state of the tissue is higher. So, simulation results show a maximal upper surface displacement of 8.79·10-8 m after 200 s of simulated time for 𝛾𝛾+ = 𝛾𝛾−= 0.72 (see Figure 5.a). When this value decreases, swelling of the sample is significantly reduced. Anyhow, ion activity coefficients seem to have a lesser effect in cartilage behavior than the other parameters. Water and ion fluxes
24 The influence of ion activity coefficients in water and ion fluxes has also been considered. Results demonstrate that, similar to diffusivity, higher values of 𝛾𝛾+ and 𝛾𝛾− yield the highest water incoming flow, 3.26·10-9 m3/s and cation (J+ = 5.50·10-5 mol/s) and anion (J- = 6.24·10-5 mol/s) outflows. A slight reduction of all fluxes is evidenced when decreasing these ion activity coefficients as shown is Figure 5.b. (a)
25 (b) Figure 5: (a) Surface displacement obtained with the 3D computational model as function of the tissue ion activity coefficients (γ+, γ-). The rest of model parameters are included in Table 1. (b) Z-displacement (uz), water (Jw), cation (J+) and ion (J-) fluxes obtained with the 3D computational model during 90 seconds of simulated time for γ+ = γ- = 0.72 and γ+ = 0.527; γ- = 0.677. Note that negative fluxes for each studied species correspond to the emergence of that component from the sample to the external bath. Conversely, positive fluxes refer to the entrance of the different components (water or ions) into the sample (tissue gain of material). Rest of parameters included in Table 1.
32 unconfined compression. Journal of Biomechanical Engineering-Transactions of the Asme 126(1): 6-16. Sun DN, Gu WY, Guo XE, Lai1 WM and Mow VC. 1999. A mixed finite element formulation of triphasic mechano-electrochemical theory for charged, hydrated biological soft tissues. International Journal for Numerical Methods in Engineering. 45(10): p. 1375-1402. Virén T, Saarakkala S, Kaleva E, Nieminen HJ, Jurvelin JS, Töyräs J. 2009. Minimally Invasive Ultrasound Method for Intra-Articular Diagnostics of Cartilage Degeneration, Ultrasound in Medicine & Biology 35(9): 1546-1554. Wilson W, van Donkelaar CC, van Rietbergen R, Huiskes R. 2005. The role of computational models in the search for the mechanical behavior and damage mechanisms of articular cartilage. Medical engineering & physics 27(10): 810-826. Wong M, Ponticiello M, Kovanen V, Jurvelin JS. 2000. Volumetric changes of articular cartilage during stress relaxation in unconfined compression. Journal of Biomechanics. 33(9): 1049-54.