Abstract
During the investigations performed after the publication of the original article, a mistake in the calibration procedure was revealed, resulting in a 50% relative increase of the estimate of the concentration of trimethylamine (TMA) in the mixtures employed. In this erratum we provide the correct concentrations after a careful re-evaluation, and therefore the statistical and systematic uncertainties are now included. The calibration procedure was performed by pre-mixing TMA with Xenon for known concentrations of the former in the range 0.5% to 50%. Several external conditions were altered, like the time before sampling and the time required for proper mixing (done with a recirculation pump), yielding deviations of about 10%. The overall statistical uncertainty was obtained from the one derived for the calibration factor, once combined with the statistical uncertainty in the estimate of the most prominent peaks of the involved species: TMA(A = 59) and Xe(A = 132), illustrated in figure 1. Generally, where it had been previously stated that the optimum for operation of Micromegas (i.e., maximum Penning transfer before excessive electron cooling) corresponded to about 1:5%TMA admixture, it should be modified to ~1%TMA after this revision. A compilation of the new concentrations can be be found in tables Cebrián, S.; Dafni, T.; Ferrer-Ribas, E.; Giomataris, I.; Gonzalez-Diaz, D.; Gómez, H.; Herrera, D.C.; Iguaz, F.J.; Irastorza, I.G.; Luzon, G.; Rodríguez, A.; Segui, L.; Tomás, A.
Full text
This content has been downloaded from IOPscience. Please scroll down to see the full text. Download details: IP Address: 155.210.94.114 This content was downloaded on 15/12/2015 at 16:41 Please note that terms and conditions apply. Erratum: Micromegas-TPC operation at high pressure in xenon-trimethylamine mixtures View the table of contents for this issue, or go to the journal homepage for more 2015 JINST 10 E07001 (http://iopscience.iop.org/1748-0221/10/07/E07001) Home Search Collections Journals About Contact us My IOPscience
2015 JINST 10 E07001 PUBLISHED BY IOP PUBLISHING FOR SISSA MEDIALAB RECEIVED:May 27, 2015 ACCEPTED:June 1, 2015 PUBLISHED:July 13, 2015 Erratum: Micromegas-TPC operation at high pressure in xenon-trimethylamine mixtures S. Cebri´ an,aT. Dafni,aE. Ferrer-Ribas,bI. Giomataris,bD. Gonzalez-Diaz,a,c,1 H. G´ omez,a,dD.C. Herrera,a,1F.J. Iguaz,aI.G. Irastorza,aG. Luzon,aA. Rodr´ıguez,a L. Seguiaand A. Tom´ asa aLaboratorio de F´ ısica Nuclear y Astropart´ ıculas, Universidad de Zaragoza, C/ Pedro Cerbuna 12, 50009, Zaragoza, Spain bIRFU, Centre d’Etudes Nucleaires de Saclay (CEA-Saclay), 91191 Gif sur Yvette, France cDepartment of Engineering Physics, Tsinghua University, Liuqing building, 10084, Beijing, China dLaboratoire de l’Acc´ el´ erateur Lin´ eaire (LAL), Universit´ e Paris-Sud 11, Bˆ atiment 200 91898 Orsay Cedex, France E-mail: [email protected] ERRATUM TO:2013 JINST 8 P01012 During the investigations performed after the publication of the original article, a mistake in the calibration procedure was revealed, resulting in a ∼50% relative increase of the estimate of the concentration of trimethylamine (TMA) in the mixtures employed. In this erratum we provide the correct concentrations after a careful re-evaluation, and therefore the statistical and systematic uncertainties are now included. The calibration procedure was performed by pre-mixing TMA with Xenon for known concentrations of the former in the range 0.5% to 50%. Several external conditions were altered, like the time before sampling and the time required for proper mixing (done with a recirculation pump), yielding deviations of about 10%. The overall statistical uncertainty was obtained from the one derived for the calibration factor, once combined with the statistical uncertainty in the estimate of the most prominent peaks of the involved species: TMA(A=59) and Xe(A=132), illustrated in figure 1. Generally, where it had been previously stated that the optimum for operation of Micromegas (i.e., maximum Penning transfer before excessive electron cooling) corresponded to about ∼1.5%TMA admixture, it should be modified to ∼1%TMA after this revision. A compilation of the new concentrations can be be found in tables 1–6. Additionally, the Micromegas pitch of 115µm quoted in the original article was found to be 100µm after microscope inspection. 1Corresponding autor. Content from this work may be used under the terms of the Creative Commons Attribution 3.0 License. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. doi:10.1088/1748-0221/10/07/E07001
2015 JINST 10 E07001 Figure 1. Spectrograms obtained from the mass spectrometer for the case of pure Xenon and for Xenon mixed with TMA. If the peaks A=59(TMA) and A=132(Xe) are selected, there is neither interference between these two species nor with impurities. Table 1. Admixtures used for the transmission scan provided in figure 2 of the original article. Detailed concentrations were not explicitly given but generally stated as ∼1.5% TMA. series P[bar] %TMA(published) %TMA(corrected) transmission 1 1.50 0.99 ±0.02(sta)±0.10(sys) 2 1.67 1.01 ±0.03(sta)±0.10(sys) 3 1.85 1.15 ±0.03(sta)±0.11(sys) 4 1.45 0.86 ±0.02(sta)±0.09(sys) 5 1.45 0.86 ±0.02(sta)±0.09(sys) 6 1.45 0.86 ±0.02(sta)±0.08(sys) 7 1.32 0.79 ±0.02(sta)±0.08(sys) 8 1.32 0.79 ±0.02(sta)±0.08(sys) 9 1.32 0.79 ±0.02(sta)±0.08(sys) 10 1.32 0.79 ±0.02(sta)±0.07(sys) –2–
2015 JINST 10 E07001 Table 2. Admixtures used for the gain scan provided in figure 5a of the original article. Table 1 and figure 7 should be modified accordingly. series P[bar] %TMA(published) %TMA(corrected) gain 1 0.4 0.25 ±0.01(sta)±0.03(sys) 1 1.4 0.91 ±0.03(sta)±0.09(sys) 1 1.7 1.22 ±0.22(sta)±0.12(sys) 1 2.4 1.51 ±0.05(sta)±0.15(sys) 1 3.4 2.30 ±0.06(sta)±0.23(sys) 1 6.4 4.52 ±0.11(sta)±0.45(sys) 1 12.4 9.28 ±0.23(sta)±0.92(sys) 1 15.5 10.41 ±0.24(sta)±1.04(sys) Table 3. Admixtures used for the gain scan provided in figure 5b of the original article. Table 1 and figure 7 should be modified accordingly. series P[bar] %TMA(published) %TMA(corrected) gain 5 0.4 0.25 ±0.01(sta)±0.02(sys) 5 0.8 0.45 ±0.01(sta)±0.05(sys) 5 1.0 0.66 ±0.02(sta)±0.07(sys) 5 1.5 0.86 ±0.02(sta)±0.09(sys) 5 2.0 1.24 ±0.03(sta)±0.12(sys) 5 2.6 1.61 ±0.04(sta)±0.16(sys) 5 3.3 2.05 ±0.05(sta)±0.20(sys) 5 4.0 2.50 ±0.06(sta)±0.24(sys) 5 5.0 2.86 ±0.07(sta)±0.28(sys) 5 6.0 3.83 ±0.09(sta)±0.37(sys) Table 4. Admixtures used for the gain scan provided in figure 5c of the original article. Table 1 and figure 7 should be modified accordingly. series P[bar] %TMA(published) %TMA(corrected) gain 8 0.3 0.20 ±0.02(sta)±0.02(sys) 8 1.2 0.76 ±0.02(sta)±0.08(sys) 8 1.9 1.17 ±0.03(sta)±0.12(sys) 8 2.3 1.43 ±0.04(sta)±0.14(sys) 8 3.3 2.04 ±0.06(sta)±0.20(sys) 8 3.7 2.34 ±0.06(sta)±0.23(sys) 8 4.4 2.71 ±0.07(sta)±0.27(sys) 8 5.0 3.27 ±0.08(sta)±0.33(sys) –3–
2015 JINST 10 E07001 Table 5. Admixtures used for the gain scan provided in figure 5d of the original article. Table 1 and figure 7 should be modified accordingly. series P[bar] %TMA(published) %TMA(corrected) gain 10 0.8 0.35 ±0.01(sta)±0.04(sys) 10 1.1 0.68 ±0.04(sta)±0.07(sys) 10 1.6 1.02 ±0.04(sta)±0.10(sys) 10 1.8 1.08 ±0.03(sta)±0.11(sys) 10 1.9 1.17 ±0.19(sta)±0.12(sys) 10 2.7 1.71 ±0.04(sta)±0.17(sys) 10 6.2 3.79 ±0.09(sta)±0.38(sys) Table 6. Admixtures used for the gain scan provided in figure 8 of the original article. Table 2 should be modified accordingly. series P[bar] %TMA(published) %TMA(corrected) gain 1 1.7 1.22 ±0.22(sta)±0.12(sys) 2 1.7 1.01 ±0.03(sta)±0.10(sys) 3 1.5 0.92 ±0.02(sta)±0.09(sys) 4 1.6 0.99 ±0.02(sta)±0.10(sys) 5 2.0 1.24 ±0.03(sta)±0.12(sys) 6 2.0 1.24 ±0.03(sta)±0.12(sys) 7 2.0 1.26 ±0.03(sta)±0.12(sys) 8 1.9 1.17 ±0.03(sta)±0.12(sys) 9 1.9 1.17 ±0.03(sta)±0.12(sys) 10 1.8 1.08 ±0.04(sta)±0.17(sys) –4–