scieee AI-readable full text Open interactive document viewer

Towards smaller gap microbulks

Attié, D; de Oliveira, R.; Giomataris, Y; Tomás, A.; Ferry, S.; Boilevin-Kayl, L.; Kebbiri, M.; Dafni, T; Herrera, D. C.; Irastorza, I. G.; Iguaz, F. J.; Seguí, L.; Papaevangelou,T.; Ferrer-Ribas, E.

Abstract

Small gap Micromegas detectors (< 50µm) are expected to be optimal for high pres- sure applications. Combining the microbulk manufacturing technique with a small gap can result in attractive detectors for rare event detection, in particular double beta decay or dark matter searches. We present novel results obtained with small gap microbulks (25 and 12.5µm) that have been manufactured recently. For the first time for this type of detectors, we show experimentally that for each amplification gap there is an optimal pressure and that smaller gaps are more suitable for higher pressures. Attié, D; Boilevin-Kayl, L.; Dafni, T; Ferrer-Ribas, E.; Ferry, S.; Giomataris, Y; Herrera, D. C.; Iguaz, F. J.; Irastorza, I. G.; Kebbiri, M.; Papaevangelou,T.; de Oliveira, R.; Seguí, L.; Tomás, A.

Full text

2014 JINST 9 C04013 PUBLISHED BY IOP PUBLISHING FOR SISSA MEDIALAB RECEIVED:December 16, 2013 ACCEPTED:February 25, 2014 PUBLISHED:April 11, 2014 3rd INTERNATIONAL CONFERENCE ON MICRO PATTERN GASEOUS DETECTORS 1–6 JULY, 2013 ZARAGOZA, SPAIN Towards smaller gap microbulks D. Atti´ e,aL. Boilevin-Kayl,aT. Dafni,bE. Ferrer-Ribas,a,∗S. Ferry,cY. Giomataris,a D.C. Herrera,bF.J. Iguaz,a,†I.G. Irastorza,bM. Kebbiri,aT. Papaevangelou,a R. de Oliveira,cL. Segu´ıb,‡and A. Tom´ asb,§ aIRFU, Centre d’ ´ Etudes Nucleaires de Saclay, (CEA-Saclay), Gif-sur-Yvette, France bInstituto de F´ ısica Nuclear y Altas Energ´ ıas, Universidad de Zaragoza, Zaragoza, Spain cEuropean Organization for Nuclear Research (CERN), Gen` eve, Switzerland E-mail: [email protected] ABSTRACT: Small gap Micromegas detectors (<50 µm) are expected to be optimal for high pressure applications. Combining the microbulk manufacturing technique with a small gap can result in attractive detectors for rare event detection, in particular double beta decay or dark matter searches. We present novel results obtained with small gap microbulks (25 and 12.5 µm) that have been manufactured recently. For the first time for this type of detectors, we show experimentally that for each amplification gap there is an optimal pressure and that smaller gaps are more suitable for higher pressures. KEYWORDS: Gaseous detectors; Micropattern gaseous detectors (MSGC, GEM, THGEM, RETHGEM, MHSP, MICROPIC, MICROMEGAS, InGrid, etc); Particle tracking detectors (Gaseous detectors); Dark Matter detectors (WIMPs, axions, etc.) ∗Corresponding author. †Present address: Instituto de F´ ısica Nuclear y Altas Energ´ ıas, Universidad de Zaragoza, Zaragoza, Spain. ‡Present address: University of Oxford, Oxford, United Kingdom. §Present address: Brackett Laboratory, Imperial College, United Kingdom. c CERN 2014, published under the terms of the Creative Commons Attribution 3.0 License by IOP Publishing Ltd and Sissa Medialab srl. Any further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation and DOI. doi:10.1088/1748-0221/9/04/C04013 2014 JINST 9 C04013 Contents 1 Introduction 1 2 Fabrication process and mesh geometry considerations 2 3 Performances of 12.5 and 25 µm gap microbulks compared to 50 µm4 3.1 Set-up description 4 3.2 Measurements at atmospheric pressure 5 3.2.1 Gain 5 3.2.2 Energy resolution measurements 7 3.3 Performance versus pressure 9 4 Conclusion and perspectives 10 1 Introduction Exploring new physics in particle or nuclear physics needs high performance detectors. The microbulk [1] is a new gaseous detector based on the Micromegas structure [2], which is now a mature technology used in different experiments such as CAST, NEXT, NTOF. The Micromegas gap is fabricated by etching of a polyimide layer, usually 50 µm thick, sandwitched between two thin metallic layers. The high accuracy of this process provides a high precision avalanche gap and it reduces gain fluctuations with improved energy resolution and detector stability. The outcome is a low-mass detector, a key element in many applications while at the same time the use of clean raw-materials provides a unique feature of an intrinsically radiopure detector [4,5]. In solar axion search (CAST experiment at CERN [6]) the microbulk is used as a low background X-ray detector since 2008. It has shown remarkable operation stability and an extremely low background level at low energy. In neutrinoless double beta decay experiments using a high pressure Xenon TPC the microbulk could be a precious tool due to its low background and enhanced energy resolution capability; developments are in progress in the context of the NEXT experiment [7–9]. In nuclear physics investigations (NTOF experiment) the low material is of paramount importance in order to provide a “neutron transparent” detector for measuring on-line neutron flux and neutron beam profile [10–12]. In previous investigations [3], it was shown that small gap Micromegas detectors would be optimum for operation at high pressure where the gain could be maximised and fluctuations due to geometrical factors or environmental ones would be cancelled. This property is important in the field of rare event searches in order to increase the sensitivity and, in the case of Xenon gas, to enhance detection efficiency of gamma rays. In [13] characterization of microbulk detectors was investigated with different gas mixtures in Argon and neon for 50 and 25 µm gaps. In the present work the study is extended down to 12.5 µm. –1– 2014 JINST 9 C04013 Table 1. Summary of the pattern of holes diameters and pitchs for the three different amplification gaps of the tested detectors. amplification gap hole diameter hole pitch (µm) (µm) (µm) 12.5 25 80 25 30 100 50 40 90 The paper is organised as follows: section 2 describes briefly the microbulk fabrication process and the mesh geometry of the studied detectors. In addition electric field simulations are presented to understand experimental results obtained with various avalanche gaps indicating the technological roadmap for future optimization of the microbulk detector. Section 3 is devoted to the performance of 25 and 12.5 µm gap microbulks compared to 50 µm including gain and energy resolution. Novel results are shown exhibiting the relation of amplification gap versus gas pressure. Finally conclusions and perspectives are discussed in section 4. 2 Fabrication process and mesh geometry considerations The manufacturing process of a microbulk detector was described in detail in [1]. Here we only remind the main three steps in figure 1. The raw material is a thin flexible kapton foil (of 25 µm or 12.5 µm) with a 5 µm copper layer on each side (figure 1step 1). A thin photoresistive film is laminated on top of the kapton foil and it is illuminated by UV light to produce the required mask (figure 1step 2). The copper is then removed by a standard lithographic process and the nonilluminated regions produce a pattern of a thin mesh. The polyimide is then etched and partially removed in order to create tiny pillars in the shadow part of the mesh below the copper mesh. In the prototypes used here the holes are 30 (25) µm in diameter with a pitch of 100 (80)µm for the 25 (12.5) µm amplification gaps in a hexagonal pattern to optimise electron transmission. A summary of the geometry of the holes diameters and pitch for the different amplifications gaps is given in table 1. In 50 µm gap Micromegas detectors, the holes diameter is usually conceived smaller than the amplification gap to favor the funnel electric field effect. In the case of the present detectors with gaps of 25 and 12 .5 µm this is not possible. The limitation comes from the attainable precision on the mask films that define the minimum mesh holes diameter. This limitation could be exceeded by an alternative more expensive technique, using glass masks, where holes of 20 µm diameter could be achieved. Going further with the present techniques seems difficult. In order to verify that the thickness of the mesh as well as the diameter of the holes will not perturb the shape of the electric field lines, a field simulation was effectuated using the Lorentz software package [14]. In figure 2the field line configuration is shown for the 12.5 and 25 µm amplification gap with a simplified geometry. The insulating kapton pillars have not been considered for these simulations. The typical funnel shape of the field lines at the mesh hole entrances seems well preserved. However figure 3shows the magnitude of the electric field at different heights within the amplification gaps across the hole as indicated in the sketch of figure 3. The depicted –2– 2014 JINST 9 C04013 Figure 1. Summary of the manufacturing process of a single anode microbulk, described in the text. electric field ranges from 99% (black points) to 1% (pink points) of the amplification gap for the three different cases (12.5, 25 and 50 µm). The 99% correspond to heights at the level of the mesh while heights of 1% correspond to heights close to the anode, where the electric field is the strongest. The voltage applied is the same for the different gaps and only relative differences are pertinent here. If we compare the ratio of the field at 99% and 1% of the amplification gap for the different gaps, we observe that for the 50 µm gap this ratio is 1.77 while for the 12.5 µm is 1.49. This means that the increase of the field near the anode for the small gaps is smaller than for the larger gaps with this hole geometry. This will probably lead to reduced gains for the small gaps. This effect would be corrected if the diameter of the holes could be reduced. The second consideration is that for the small gaps there is greater dispersion of the magnitude of the electric field close to the anode i.e for the 50 µm the magnitude of the electric field is nearly constant from heights greater than 50%. Another way of seeing this effect, is by looking at the integration of the electric field across the amplification gap. Figure 4shows the integrated electric field across the amplification gap at two different positions: at the middle of the hole and a position shifted of 15% to one side as shown in the sketch. The difference between the two curves is greater for the small gaps than for the 50 µm. In particular the difference between the integration of the two positions at the level of the anode at the maximum of the electric field is only of 1% while for the 12.5 µm amplification gap the difference reaches 8%. In addition, the averaged integrated field ratio between the two positions is of 12% for the 12.5 µm amplification gap and only of 5% for the 50 µm amplification gap meaning that the avalanche will take place in a similar manner regardless –3– 2014 JINST 9 C04013 Figure 2. Field line simulation of a 12.5 and 25 µm amplification gap Micromegas detector with the hole and pitch dimensions described in table 1. of position within the hole for the 50 µm amplification gap. This fact will probably have an effect on the energy resolution. 3 Performances of 12.5 and 25 µm gap microbulks compared to 50 µm The microbulks of 50 µm are relatively well-known. They have been well characterised [1,7,13] and are being used in the CAST experiment [1], in the R&D for the NEXT experiment [8] and in the NTOF [10]. In the next section we will compare the performance of the novel small gap microbulk with respect to the well known 50 µm amplification gap ones. In particular, it is the first time that the behaviour of smaller gap microbulks as a function of pressure (from 0.4 bar to 1.7 bar) is studied in Argon-Isobutane mixtures. 3.1 Set-up description The detectors were installed in an aluminium vessel with an aluminized mylar window allowing calibration by X-rays from an 55Fe source. The prototypes used in these tests are single anode round detectors with an active zone of a diameter of 35 mm. A picture of the detector and a zoom of the active area are shown in figure 5. The gas mixture was allowed to circulate for several hours before each measurement and at every change of the gas mixture or the pressure. To maintain the drift gap, a mesh frame is layed on 10 mm pillars. The mesh signal was read out by an ORTEC 142B preamplifier followed by a CANBERRA 2022 Spectroscopy amplifier. The pulse height distributions are recorded by a multi-channel analyzer AMPTEK MCA-8000A. Each spectrum –4– 2014 JINST 9 C04013 Anode Mesh E @ 75% E @ 50% E @ 25% E @99% E @ 1% m)µDistance from the center of the hole ( -20 -15 -10 -5 0 5 10 15 20 Amplification field (V/m) 10 20 30 40 50 6 10× __ E @ 99% ampl. gap E @ 75% ampl. gap E @ 50% ampl. gap E @ 25% ampl. gap E @ 1% ampl. gap m gapµ12.5 m)µDistance from the center of the hole ( -20 -15 -10 -5 0 5 10 15 20 Amplification field (V/m) 5 10 15 20 25 6 10× __ E @ 99% ampl. gap E @ 75% ampl. gap E @ 50% ampl. gap E @ 25% ampl. gap E @ 1% ampl. gap m gapµ25 m)µDistance from the center of the hole ( -30 -20 -10 0 10 20 30 Amplification field (V/m) 2 4 6 8 10 12 6 10× __ E @ 99% ampl. gap E @ 75% ampl. gap E @ 50% ampl. gap E @ 25% ampl. gap E @ 1% ampl. gap m gapµ50 Figure 3. Sketch to illustrate the electrostatic simulation (top left). Magnitude of the electric field at different heights within the amplification holes for the 12 (top right), 25 (bottom left) and 50 (bottom right) µm amplification gaps. was fitted by two Gaussian functions, corresponding to the Kα(5.9 keV) and Kβ(6.4 keV) lines of the 55Fe source; the mean position and width of the main peak were obtained for each fit. 3.2 Measurements at atmospheric pressure 3.2.1 Gain The 25 and 12.5 µm detectors were tested at atmospheric pressure with different percentages of Isobutane. A scan of the drift field was done at fixed amplification field in order to obtain the electron transmission and to find the range of optimal operation. The result is shown in figure 6 exhibiting a similar behaviour for the two different gaps. It is noteworthy that there is a wide range of ratios of drift and amplification fields, where the relative electron transmission is greater than 90%. The region where the electron transmission is constant, called the plateau, is extended when the percentage of Isobutane is increased [15]. This effect is correlated with the diffusion coefficient and was already verified in [7,13,20]. On the other hand, there is a steady increase of the gain with the drift field that is more prominent at high Isobutane concentrations and for the 12.5 µm gap. This effect was already observed in [13] and has been simulated with the neBEM and Garfield [16,17]. At high drift fields, the mesh stops being transparent as some of the field lines stop at the mesh and part of the electrons are lost. In order to obtain the gain of the detector as a function of amplification field, the ratio of drift and amplification field is set at the maximum of transmission. Figure 7shows the gain versus –5– 2014 JINST 9 C04013 Anode Mesh E center of the hole E off center of the hole Integration from mesh to anode Distance accross the hole (µm) 0 2 4 6 8 10 12 Integrated Electric Field (V/m) 10 12 14 16 18 20 6 10× __ Center of the hole Off center of hole (15%) m gapµ12.5 Distance accross the hole (µm) 0 5 10 15 20 25 Integrated Electric Field (V/m) 4 5 6 7 8 9 10 11 12 6 10× __ Center of the hole Off center of hole (15%) m gapµ25 Distance accross the hole (µm) 0 5 10 15 20 25 30 35 40 45 50 Integrated Electric Field (V/m) 2000 2500 3000 3500 4000 4500 5000 5500 6000 3 10× __ Center of the hole Off center of hole (15%) m gapµ50 Figure 4. Integrated electric field across the amplification gap for the 12 (a), 25 (b) and 50 (c) µm amplification gaps. The full line corresponds to the integrated electric field at the center of the hole whilst the dashed line corresponds to the integrated field shifted of 15% from the center of the hole. Figure 5. Left: picture of a 3.5 cm diameter circular microbulk used in these tests. Right: zoom of the active area. The hexagonal pattern of the 30 µm diameter mesh holes with a pitch of 100 µm can be observed. amplification fields for different gas mixtures for 12.5 µm (left) and 25 µm (right) amplification gaps. Gains greater than 7 ×103are obtained for the 12.5 µm gap. For the 25 µm, the maximum gains reach 104for concentrations of 15% and 20%. The maximum gains observed are below the sparking point of the detector, i.e the detectors have not been pushed to the limit. The results for the 25 µm detectors corroborate the previous measurements in [13]. In order to have a common point of comparison, figure 8shows the gain for the three different gaps in the same conditions, at atmospheric pressure in an Ar + 10% Isobutane mixture showing that the highest gains are obtained for the 50 µm gap despite the lowest electric field applied as the distance for the avalanche to develop is larger. –6– 2014 JINST 9 C04013 Ratio of drift and amplification fields  0.000 0.002 0.004 0.006 0.008 0.010 Electron transmission 0.70 0.75 0.80 0.85 0.90 0.95 1.00 1.05 __ Ar+Iso10% Ar+Iso15% Ar+Iso20% Ar+Iso30% Ar+Iso35% m gapµ12.5 Ratio of drift and amplification fields  0.000 0.002 0.004 0.006 0.008 0.010 Electron transmission 0.70 0.75 0.80 0.85 0.90 0.95 1.00 1.05 __ Ar+Iso2.5% Ar+Iso5% Ar+Iso7.5% Ar+Iso10% Ar+Iso15% Ar+Iso20% m gapµ25 Figure 6. Electron transmission versus ratio of drift and amplification fields for different gas mixtures for 12.5 µm (left) and 25 µm (right) amplification gaps. Amplification field (kV/cm) 200 210 220 230 240 250 260 270 280 Absolute gain 3 10 4 10 __ Ar+Iso10% Ar+Iso15% Ar+Iso20% Ar+Iso30% Ar+Iso35% m gapµ12.5 Amplification field (kV/cm) 90 100 110 120 130 140 150 160 Absolute gain 3 10 4 10 __ Ar+Iso2.5% Ar+Iso5% Ar+Iso7.5% Ar+Iso10% Ar+Iso15% Ar+Iso20% m gapµ25 Figure 7. Gain versus amplification fields for different gas mixtures for 12.5 µm and 25 µm amplification gaps. 3.2.2 Energy resolution measurements The energy resolution has been studied for different concentrations of Isobutane. The results are shown in figure 9. For a given gas mixture the energy resolution increases with gain as the signal to noise ratio is increased. Normally a minimum is reached and at high gain a degradation can be observed due to the extra fluctuations [18]. This degradation is not observed neither for the 12.5 µm nor for the 25 µm. As in the gains studies, detectors have not been pushed to the sparking limit. Regarding the percentage of quencher, at low concentrations the energy resolution is worse as not all the UV photons in the avalanche are absorbed. The best energy resolution is obtained at Ar + 10% Isobutane and Ar + 20% mixtures for the 25 µm and12.5 µm respectively. These concentrations, that seem optimum for the energy resolution, will be the reference ones to study the performance as a function of pressure in the next section. In order to obtained the ultimate energy resolution we have repeated the measurement using a chrome foil in order to select the Kα(5.9 keV) line of the 55Fe. This is shown in figure 10. We can see that these values, 12% and 11% for the 25 and 50 µm gaps respectively are close to the theoretical limitations and do not depend on our fitting procedure. –7– 2014 JINST 9 C04013 Amplification field (kV/cm) 50 100 150 200 250 Absolute gain 3 10 4 10 5 10 __ mµbulk 12.5 µ mµbulk 25 µ mµbulk 50 µ Patm with 10%Iso Figure 8. Comparison of gain for the different gaps at atmospheric pressure in Ar + 10% Isobutane. Amplification field (kV/cm) 200 210 220 230 240 250 260 270 280 Energy resolution (%FWHM) 10 15 20 25 30 35 __ Ar+Iso10% Ar+Iso15% Ar+Iso20% Ar+Iso30% Ar+Iso35% m gapµ12.5 Amplification field (kV/cm) 90 100 110 120 130 140 150 160 Energy resolution (%FWHM) 10 15 20 25 30 35 __ Ar+Iso2.5% Ar+Iso5% Ar+Iso7.5% Ar+Iso10% Ar+Iso15% Ar+Iso20% m gapµ25 Figure 9. Resolution versus amplification fields for different gas mixtures for 12.5 µm and 25 µm amplification gaps. This is observed by calculating the lower limit on the obtainable energy resolution in gas detectors taking into account primary and avalanche fluctuations. It can be written as follows: σE E(FWHM) = 2.35rW E0 (F+b),(3.1) where Wis the mean energy per ion pair, E0is the initial total energy of the ionization particle, Fis the Fano factor and bis the relative variance for the distribution of the number of electrons produced in a single avalanche. Using typical values of F=0.2, W=25 eV and b=0.5 [19], the minimum resolution at 5.9 keV is 10.8% (FWHM). –8–