Full text
This content has been downloaded from IOPscience. Please scroll down to see the full text. Download details: IP Address: 155.210.94.122 This content was downloaded on 06/01/2015 at 16:39 Please note that terms and conditions apply. Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy γ-rays View the table of contents for this issue, or go to the journal homepage for more 2014 JINST 9 C04015 (http://iopscience.iop.org/1748-0221/9/04/C04015) Home Search Collections Journals About Contact us My IOPscience
2014 JINST 9 C04015 PUBLISHED BY IOP PUBLISHING FOR SISSA MEDIALAB RECEIVED:November 23, 2013 ACCEPTED:February 22, 2014 PUBLISHED:April 11, 2014 3rd INTERNATIONAL CONFERENCE ON MICRO PATTERN GASEOUS DETECTORS 1–6 JULY, 2013 ZARAGOZA, SPAIN Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy γ-rays The NEXT collaboration V. ´ Alvarez,aF.I.G.M. Borges,dS. C´ arcel,aJ. Castel,b,cS. Cebri´ an,b,cA. Cervera,a C.A.N. Conde,dT. Dafni,b,cT.H.V.T. Dias,dJ. D´ıaz,aM. Egorov,fR. Esteve,g P. Evtoukhovitch,hL.M.P. Fernandes,dP. Ferrario,aA.L. Ferreira,iE.D.C. Freitas,d V.M. Gehman,fA. Gil,aA. Goldschmidt,fH. G´ omez,b,cJ.J. G´ omez-Cadenasa,∗ D. Gonz´ alez-D´ıaz,b,c,†R.M. Guti´ errez,jJ. Hauptman,kJ.A. Hernando Morata,l D.C. Herrera,b,cF.J. Iguaz,b,cI.G. Irastorza,b,cM.A. Jinete,jL. Labarga,mA. Laing,a I. Liubarsky,aJ.A.M. Lopes,dD. Lorca,aM. Losada,jG. Luz´ on,b,cA. Mar´ı,g J. Mart´ın-Albo,aA. Mart´ınez,aG. Mart´ınez-Lema,lT. Miller,fA. Moiseenko,h F. Monrabal,aC.M.B. Monteiro,dF.J. Mora,gL.M. Moutinho,iJ. Mu˜ noz Vidal,a H. Natal da Luz,dG. Navarro,jM. Nebot-Guinot,aD. Nygren,fC.A.B. Oliveira,f R. Palma,nJ. P´ erez,oJ.L. P´ erez Aparicio,nJ. Renner,fL. Ripoll,pA. Rodr´ıguez,b,c J. Rodr´ıguez,aF.P. Santos,dJ.M.F. dos Santos,dL. Segui,b,cL. Serra,aD. Shuman,f A. Sim´ on,aC. Sofka,qM. Sorel,aJ.F. Toledo,gA. Tom´ as,b,cJ. Torrent,p Z. Tsamalaidze,hD. V´ azquez,lJ.F.C.A. Veloso,iJ.A. Villar,b,cR.C. Webb,q J.T. White,q,‡and N. Yahlalia F. Aznar,b,cD. Calvet,eF. Druillole,eE. Ferrer-Ribas,eJ. A. Garc´ıa,b,cI. Giomataris,e J. Gracia,b,cA. Le Coguie,eJ.P. Mols,eP. Pons,bE. Ruizb aInstituto de F´ ısica Corpuscular (IFIC), CSIC & Universitat de Val` encia, Calle Catedr´ atico Jos´ e Beltr´ an, 2, 46980 Paterna, Valencia, Spain bLaboratorio de F´ ısica Nuclear y Astropart´ ıculas, Universidad de Zaragoza, Calle Pedro Cerbuna 12, 50009 Zaragoza, Spain ∗Spokesperson ([email protected]). †Corresponding author. ‡Deceased. c 2014 IOP Publishing Ltd and Sissa Medialab srl doi:10.1088/1748-0221/9/04/C04015
2014 JINST 9 C04015 cLaboratorio Subterr´ aneo de Canfranc, Paseo de los Ayerbe s/n, 22880 Canfranc Estaci´ on, Huesca, Spain dDepartamento de Fisica, Universidade de Coimbra, Rua Larga, 3004-516 Coimbra, Portugal eIRFU, Centre d’ ´ Etudes Nucl´ eaires de Saclay (CEA-Saclay), 91191 Gif-sur-Yvette, France fLawrence Berkeley National Laboratory (LBNL), 1 Cyclotron Road, Berkeley, California 94720, U.S.A. gInstituto de Instrumentaci´ on para Imagen Molecular (I3M), Universitat Polit` ecnica de Val` encia, Camino de Vera, s/n, Edificio 8B, 46022 Valencia, Spain hJoint Institute for Nuclear Research (JINR), Joliot-Curie 6, 141980 Dubna, Russia iInstitute of Nanostructures, Nanomodelling and Nanofabrication (i3N), Universidade de Aveiro, Campus de Santiago, 3810-193 Aveiro, Portugal jCentro de Investigaciones en Ciencias B´ asicas y Aplicadas, Universidad Antonio Nari˜ no, Carretera 3 este No. 47A-15, Bogot´ a, Colombia kDepartment of Physics and Astronomy, Iowa State University, 12 Physics Hall, Ames, Iowa 50011-3160, U.S.A. lInstituto Gallego de F´ ısica de Altas Energ´ ıas (IGFAE), Univ. de Santiago de Compostela, Campus sur, R´ ua Xos´ e Mar´ ıa Su´ arez N´ u˜ nez, s/n, 15782 Santiago de Compostela, Spain mDepartamento de F´ ısica Te´ orica, Universidad Aut´ onoma de Madrid, Campus de Cantoblanco, 28049 Madrid, Spain nDpto. de Mec´ anica de Medios Continuos y Teor´ ıa de Estructuras, Univ. Polit` ecnica de Val` encia, Camino de Vera, s/n, 46071 Valencia, Spain oInstituto de F´ ısica Te´ orica (IFT), UAM/CSIC, Campus de Cantoblanco, 28049 Madrid, Spain pEscola Polit` ecnica Superior, Universitat de Girona, Av. Montilivi, s/n, 17071 Girona, Spain qDepartment of Physics and Astronomy, Texas A&M University, College Station, Texas 77843-4242, U.S.A. E-mail: [email protected] ABSTRACT: NEXT-MM is a general-purpose high pressure (10 bar, ∼25 l active volume) Xenonbased TPC, read out in charge mode with an 0.8 cm×0.8 cm-segmented 700 cm2plane (1152 ch) of the latest microbulk-Micromegas technology. It has been recently commissioned at University of Zaragoza as part of the R&D of the NEXT 0νββ experiment, although the experiment’s first stage is currently being built based on a SiPM/PMT-readout concept relying on electroluminescence. Around 2 million events were collected during the last months, stemming from the low energy γrays emitted by a 241Am source when interacting with the Xenon gas (Eγ=26, 30, 59.5 keV). The localized nature of such events around atmospheric pressure, the long drift times, as well as the possibility to determine their production time from the associated αparticle in coincidence, allow the extraction of primordial properties of the TPC filling gas, namely the drift velocity, diffusion and attachment coefficients. In this work we focus on the little explored combination of Xe and trimethylamine (TMA) for which, in particular, such properties are largely unknown. This gas mixture offers potential advantages over pure Xenon when aimed at Rare Event Searches, mainly
2014 JINST 9 C04015 due to its Penning characteristics, wave-length shifting properties and reduced diffusion, and it is being actively investigated by our collaboration. The chamber is currently operated at 2.7 bar, as an intermediate step towards the envisaged 10 bar. We report here its performance as well as a first implementation of the calibration procedures that have allowed the extension of the previously reported energy resolution to the whole readout plane (10.6% FWHM@30 keV). KEYWORDS: Time projection Chambers (TPC); Micropattern gaseous detectors (MSGC, GEM, THGEM, RETHGEM, MHSP, MICROPIC, MICROMEGAS, InGrid, etc); Double-beta decay detectors; Charge transport and multiplication in gas ARXIV EPRINT:1311.3535
2014 JINST 9 C04015 Contents 1 Introduction 1 2 Overall TPC behaviour and performance of the Micromegas readout at 1–2.7 bar 2 2.1 Description of the experimental setup 2 2.2 Data taking and analysis 5 2.3 Gain calibration and system behavior 8 3 Extraction of the parameters of the electron swarm 11 3.1 Pulse-shape analysis 11 3.2 Determination of the total Drift Time 12 3.3 Drift velocity and diffusion coefficients of Xe/TMA mixtures 14 3.4 Attachment coefficient in Xe/TMA mixtures 17 4 Discussion 18 5 Conclusions 20 1 Introduction NEXT-100 is a 0νββ experiment to be located at the Laboratorio Subterr´ aneo de Canfranc (LSC) in the Spanish Pyrenees [1,2], with its first stage currently undergoing construction [3]. Notably, it is the only next generation 0νββ experiment that uses a ββ-isotope in gaseous phase (136Xe, 100–150 kg) and thus it aims at maximally exploiting the topological features of the 2e−ββ-decay mode [4]. The ability to recognize and separate the golden 2-blob signal from spurious (singleblob) γbackgrounds is one of the experiment’s key features, relying for that on a Time Projection Chamber (TPC) architecture. Its second strength, as compared to earlier approaches [5], is the use of proportional light multiplication (namely, electroluminescence/EL), a technique capable of providing near-intrinsic energy resolution in pure Xenon, down to 0.5% FWHM@Qββ [6]. The design goals as of the technical design report released by the collaboration [2] have been confirmed for 1 kg-scale demonstrators in a series of papers [4,6–8]. The fact that Xenon is in gas phase at standard P,Tconditions reduces the cost of the enrichment process (the isotopic content of 136Xe in natural Xenon is 9%), making it one of the ββ-isotopes with the lowest price/mass ratio. However the gas phase offers yet additional advantages, for instance allowing readily for the combination with suitable gas dopants. Admixtures of some % (sometimes sub-%), specially in noble gases, are known to intensely modify the characteristics of the main gas by quenching or wavelength-shifting its scintillation spectrum [9], enhancing energy-transfer ionizing (Penning) reactions [10], modifying the charge recombination process [11] –1–
2014 JINST 9 C04015 or affecting generic properties of the electron swarm like diffusion and drift velocity [12], or attachment [13]. A remarkable example currently under study, the trimethylamine molecule (TMA), potentially exhibits a desirable behaviour concerning all the above aspects when teaming up with Xenon [14], such mixtures being however poorly known [15–17]. As an example, despite the electron drift velocity for pure Xenon (see [6] for instance) and pure TMA [18] being long measured, data for Xe/TMA mixtures were not available until recently [17] to the best of the authors’ knowledge. We make use in this work of the recently commissioned NEXT-MM TPC [19] that, thanks to its large drift distance (38 cm) and finely segmented charge readout, allows a more exhaustive characterization of Xe/TMA mixtures as compared to [17], thus providing the diffusion and attachment coefficients. On the other hand, and perhaps most notably, NEXT-MM currently features the largest pixelated readout plane world-wide (700 cm2) based on the novel microbulk-Micromegas technology [20]. Hence, except for the pioneering work realized on 10 cm2-readout TPCs in [16], nothing is known about the performance of large systems based on this kind of readouts when operated in high pressure Xenon mixtures. In order to further scrutinize this latter aspect, as well as to properly substantiate some of the analysis procedures here described, this contribution is structured as follows: in section 2the experimental setup, the data taking and calibration procedures are introduced, together with a description of the main TPC performance in the pressure range 1– 2.7 bar; in section 3the extraction of some relevant parameters of the electron swarm for Xe/TMA is performed and a short discussion follows. 2 Overall TPC behaviour and performance of the Micromegas readout at 1–2.7 bar 2.1 Description of the experimental setup The experimental setup used is very similar to the one described in [19], that is shown in figure 1. A radioactive source consisting of a thin layer of 241Am (A=500 Bq) electro-deposited in one of the two large faces of a cylindrical metal disk (2.5 mm-thick) was employed. The disk itself was opaque to α’s. It was enclosed in a PTFE structure attached to the TPC cathode (figure 1, up-right) with its radioactive deposit facing the cathode of a silicon diode. The signal produced by an αparticle traversing the diode (εα=5.5 MeV) provided the start time (T0) of the event, thus tagging the nuclear decay. Due to the limited solid angle coverage of the (extended) source, the diode rate reached only rT0∼40 Hz. For these measurements we made use of the fact that 241Am αparticles are emitted largely in coincidence with 59.5 keV γ’s from the 237Np daughter nuclei, that were able to enter and ionize the active volume of the TPC for about a fraction f=1/15 of all events. The relatively large mean free path of this emission (λ59.5,Xe =20 cm@1 bar, table 2) provided a sizeable ionization probability over the full TPC volume. The trigger signal was built with the T0-signal from the diode in coincidence with a positive signal from the TPC itself, in order to enhance the γcontent in data. The latter was formed by an ‘OR’ of the signals induced at the cathode of each Micromegas quadrant (hereafter referred to as ‘mesh’). Application of an energy threshold of 10 keV on the mesh signals required operating the Micromegas plane with a gain around 2000, close to the spark limit previously reported in [16]. The trigger rate rtrigger =f×rT0≃2 Hz amounted to one million events for each regular week of data taken, out of which 10% were fake noise triggers and nearly 30% random, typically (figure 2). –2–
2014 JINST 9 C04015 Figure 1. Experimental setup used for the characterization of NEXT-MM with low energy γphotons, under a Xe/TMA mixture. Left: transverse section of NEXT-MM showing the field cage, source position and readout plane. Right-up: close-up of the 241Am source in its PTFE enclosure. Right-down: photo of the readout plane, showing the arrangement in 4 separate quadrants. 0 20 40 60 80 100 120 140 160 180 200 220 240 260 0 2000 4000 6000 8000 tevt [µs] events (in µs bin) To after delay (trigger time) fake coincidences (with MM−mesh noise) post−trigger To before delay end of DAQ window random coincidences pre−trigger coincidence window γ interactions from 241Am source Xe/TMA (97.8/2.2), P=1 bar Edrift = 145.5 V/cm εth,mesh ∼ 10keV mMM = 2×103 εth,pixel = 1keV Figure 2. Distribution of event times registered at NEXT-MM when triggering in coincidence with α’s from a241Am source, detected in an auxiliary Si-diode. The observed exponential shape is dominated by the mean free path of the 59.5 keV γemitted in the decay of 237Np to its ground state, modulated by solid angle and other geometrical effects. The edges of the TPC cathode and the readout plane are clearly discernible over a flat background. The chosen settings reflect typical working conditions described in the text. –3–
2014 JINST 9 C04015 For each triggered event the signals from the segmented anode plane of the Micromegas were amplified, sampled and stored with the help of a data acquisition system (DAQ) based on the one developed for the T2K experiment [21], whose front end card (FEC) relies on the AFTER chip. This electronics, intrinsically capable of providing an accurate signal sampling down to 20 ns time bins and low (sub-1000e- ENC) noise figure, is at the core of the NEXT-MM TPC concept. In the present experimental conditions it was convenient to select a time sampling in the range 0.3- 0.9µs as well as the largest shaping time available (τ=2µs). The lowest amplification of the FEC was chosen, providing a dynamic range of 600 fC. Recorded events are shown later (figure 7) and several examples of extended tracks can be found in [19]. An absolute time can be associated to each event, defined as the mean of the pulses’ peaking times (tpeak) obtained from all pulses (Nfired) above a given threshold (εth,pixel): tevt =1 Nfired Nfired ∑ i=1 tpeak,i(2.1) The synchronization of the acquisition system with the arrival times of the γ-ray charge deposits to the readout plane (tevt, from eq. (2.1)) can be illustrated with the help of figure 2, resorting for that to a raw sample of 5 ×105events. The procedure can be summarized as follows. First, each mesh signal was amplified through a Canberra chain (models 2004 and 2022) and later discriminated. An ‘OR’ signal was produced by a coincidence module (CAEN-N455) and its output enlarged with a dual timer (CAEN-2255B) to a width comfortably exceeding the anticipated drift time region. This procedure set the coincidence window, to which the T0diode signal (200 ns wide) was incorporated under an ‘AND’ condition. In order for the resulting trigger signal to convey the T0on its rising edge, the diode signal had been previously delayed by a time exceeding the drift region but smaller than the coincidence window. At last, the window of the data acquisition system was opened upon the trigger arrival, by defining a certain amount of pre and post-trigger time, with the pre-trigger time chosen to exceed the duration of the coincidence window. The main merit of this experimental configuration is to allow for the accurate identification of the positions of the TPC cathode and the readout plane without resorting to external information. They appear as the edges of a nearly exponential distribution superimposed on a flat background, with a large fraction of coincidences coming from the source itself (after background subtraction the edge corresponding to the readout plane, situated around the arrow labeled ‘Tobefore delay’ in figure 2, is further enhanced as shown in figure 8). A detailed description of the gas system can be found in [17]. For the present measurements Xenon (purity grade 6) and trimethylamine were used. Special care was taken with the latter, supplied in a bottle for which a large O2contamination was determined before hand with the help of a mass spectrometer. Purification was realized by first cryo-pumping the gas into a 2 l stainlesssteel bottle immersed in a Dewar flask filled with liquid N2. After been reclaimed, the residual vapor in the bottle was pumped (still at cryogenic temperature) under the assumption that the O2 present in the system remained in gas phase or with a sizeable vapor pressure. Whenever TMA was injected in the gas system this purification procedure was followed, and iterated if evidence was found of any O2contamination remaining. In case the chamber had been previously opened in air (for maintenance or reparation works) a single bake-out cycle as described in [19] followed. In order to further enhance the quality of the gas, recirculation in close-loop through a FaciliTorr filter –4–
2014 JINST 9 C04015 Table 1. Summary of the experimental campaigns conveyed in this work. The reduced field in the multiplication region (EMM) is estimated through division of the voltage at the Micromegas cathode by the amplification gap, normalized to the working pressure. It corresponds to a gain of ×2000 for the 1 bar campaigns and ×1600 for the 2.7 bar one. campaign # runs evts Edrift/P[V/cm/bar] EMM/P[kV/cm/bar] P[bar] Xe/TMA I 2 8 ×105145.5 54 1.0 97.8/2.2 II 5 10666.6-164.0 54 1.0 97.8/2.2 III 2 6 ×105103.6 25 2.7 97.6/2.4 by SAES was performed at around 10 Nl/h, and about 1–2 days were awaited before data taking started. According to the provider the filter can be operated under TMA, however an unwelcome reactive behaviour was observed, reaching stationary conditions only after several minutes [16]. In this respect, due to the large gas volume employed in these measurements no effect could be noticed. The maximum pressure reached for the present campaigns (2.7 bar) in our ∼70 l-TPC roughly corresponds to the pressure limit of the gas system in the neighborhood of the 2 l recovery bottle (about 60–70 bar, far from the ideal gas behaviour). The possibility of a fast recovery is a valuable asset of this type of system in view of the high amount of Xenon gas employed (nearing MXe =5kg at 10 bar).1 2.2 Data taking and analysis Around 2 ×106events were stored during 3 experimental campaigns, summarized in table 1: i) a high statistics campaign and ii) a drift-field scan, both at P=1 bar, and iii) a high statistics campaign at P=2.7 bar. For all three an internal insulation problem in the anode signal distribution of the first quadrant limited the TPC readout to 3/4 of its total area, out of which 92% was fully operational (for details see [19]). The data analysis described in this section is based on simple algorithms and no detailed pulse shape analysis (PSA) has been attempted. It starts from the DAQ- stored 511-point waveforms of all 288 ×3 active electronic channels/pixels containing the raw information to be analyzed. Upon pedestal subtraction, a threshold in amplitude corresponding to ∼1 keV was set for each channel. When crossing the threshold, the initial estimate of the pulse charge (obtained from the pulse amplitude) was refined through the determination of the pulse area, in order to correct for any residual ballistic deficit, providing Qi. The position of the event in the transverse plane, xevt,yevt, could be then obtained through a standard linear weighting procedure based on the estimated charge: Qevt = Nfired ∑ i Qi(2.2) xevt =1 Qevt Nfired ∑ i Qixi(2.3) yevt =1 Qevt Nfired ∑ i Qiyi(2.4) 1Meanwhile the gas system has been upgraded and is currently operating at 10 bar. –5–
2014 JINST 9 C04015 40 60 80 100 120 140 160 0 500 1000 1500 2000 2500 3000 tM [µs] events (in 1µs bin) Figure 8. Timing characteristics of localized energy deposits in the TPC at Edrift =145.5 V/cm (P=1bar) for a mixture of Xe/TMA in proportion 97.8/2.2. Left: width-time correlation curve (σ2 t,M−tM) for the pixel containing the highest fraction of the event charge, for events gated around the escape peak energy (25keV< εevt <35keV). Right: time distribution for those events before (black) and after (red) the correlation cut (red lines on left-figure) used to suppress random coincidences from the source itself. The magnitude tMhas an offset relative to the start-time of the DAQ window. The offset in σ2 t,Mis mainly due to the electronics response function, with a small contribution coming from the size of the ionization cloud. Naturally, the values of ¯ tjand σt,jobtained from the fit to eq. (3.1) are related to the electron drift velocity and longitudinal diffusion. In order to minimize the contribution of the size of the initial ionization cloud to the estimate of these parameters we focus on 30 keV events, in particular on the pixel carrying the highest fraction of the event charge (about 70% in average, figure 10- right). Signals from those pixels are nearly always described by a single Gaussian fit and hence they allow for the simplified notation tM≡¯ tjand σt,M≡σt,j, used hereafer. The σ2 t,M−tMcharacteristics of 30 keV events in the TPC are shown for illustration in figure 8- left, for a drift field Edrift =145.5 V/cm and a mixture of Xe/TMA at 97.8/2.2 and P=1 bar. The observed straight line is expected from longitudinal diffusion: σ2 t,M=σ2 0+2DL v2 d (tM−tano)(3.2) with DLreferring to the longitudinal diffusion coefficient and vdto the electron drift velocity. The offset σ2 0contains the effect of the convolution with the electronics response function and, to a lesser extent, the space extension of the ionization cloud, both being z-independent (see the discussion section). The σ2 t,M−tMcorrelation is so strong in present conditions that all remaining random coincidences with events originated at the source can be easily suppressed (figure 8-right). 3.2 Determination of the total Drift Time The time (tM) distributions obtained for 30 keV events are characterized by a sharp left edge, attributed to the readout plane, and by a relatively smooth right edge near the cathode. The cathode edge is smoothed due to the ‘shadow’ created by the extended 241Am source (1 cm diameter) when illuminating the cathode hole edge. Additionally, for radii smaller than the cathode hole (revt <2 cm) fringe fields slow down the primary electron swarm, further enhancing the time spread – 12 –
2014 JINST 9 C04015 40 60 80 100 120 140 160 0 500 1000 1500 2000 2500 3000 tM [µs] events (in 1µs bin) cathodeanode Figure 9. Sketch of the procedure used for determining the TPC drift region under γirradiation at Edrift/P= 145.5 V/cm/bar, P=1 bar. Left: time distribution and fit to the function introduced in the text (red line). Right-up: approximate sketch of the geometry in the source region. Right-down: the apparent position of the cathode for different slices in the radial position of the energy deposit (revt) as obtained from the left fit. The estimate of the cathode position (tcat =150 µs) from this differential analysis exceeds by about 3µs the value obtained from a global fit. (figure 9-right). For the extraction of the parameters of the swarm as here intended, a fiducial cut was applied by removing events having any charge deposit within 2.5 cm of the boundaries of the active region of the readout plane (given by figure 3-left), leaving a usable area of around 400 cm2 for the present analysis. A convenient parameterization of the time distribution can be found by resorting to the convolution of an exponential function (approximating the physical distribution of events along the drift region) with a Gaussian distribution that characterizes the aforementioned geometrical effect through its width σg. The resulting distribution can be expressed as the difference of two error functions (erf): f(tM) = CetM/τ∗"erf tcat −σ2 g/τ∗−tM √2σg!−erf tano −σ2 g/τ∗−tM √2σg!#Θ(tM−tano)+B(3.3) The pre-factor Cstands for a normalization constant, Bis the background level and tcat(ano)refer to the absolute times (provided by the DAQ) assigned to the cathode and anode edge, respectively. The dominant attenuation law behavior is parameterized through an effective electron life-time τ∗. A sharp step-function Θ(tM−tano)is introduced at the anode edge as seen in data. An example of a typical fit to eq. (3.3) is shown in figure 9-left for a drift field Edrift =145.5 V/cm and 1 bar pressure, yielding a drift region enlarged by about 5% with respect to a naive estimate from the position of the cathode peak. Besides smoothing the cathode region, the geometrical ‘shadow effect’ causes an apparent shift in the cathode position as a function of the radial coordinate of the charge deposit, approximately following a straight line (figure 9-right). This makes the estimate of the drift region differ by about 2% relative to that obtained through a direct fit performed without any radial selection, and so tcat must be corrected accordingly. The time span of the drift region can be finally obtained as ∆T=tcat −tano. – 13 –
2014 JINST 9 C04015 3.3 Drift velocity and diffusion coefficients of Xe/TMA mixtures The statistical uncertainty on the determination of the drift region resulting from the fit to eq. (3.3) as well as the mechanical accuracy in the drift region (D=38 cm) are around 1%, that directly translate into the corresponding uncertainty in the drift velocity vd=D/∆T. Nevertheless, the present uncertainty of our experimental setup is presumably dominated by the procedure used to identify the cathode position, therefore we assign in the following a maximum 5% systematic uncertainty to vd, the typical difference observed between an estimate from the fit and one from the cathode peak position. More systematic studies and/or a single measurement in a well known gas will expectedly reduce the present uncertainty in future measurements to near the statistical levels. By studying the properties of localized charge deposits as a function of the drift distance, zM= vd×(tM−tano), it is possible to extract information about the diffusion and attachment coefficients. Figure 10-left shows the behaviour of σt,M−zMin narrow z-slices obtained for various runs that are later used for the extraction of the longitudinal diffusion coefficient. The reduction of diffusion with increased pressure (points) is apparent, as expected. Another relevant feature is that for most of the data sets, except for Edrift/P=66.6 V/cm/bar (diamonds), a consistent value of the vertical intercept (σ0) is observed (the deviation arises from the much reduced drift velocity in this case, a fact that has been used in the discussion section to estimate the size of the initial ionization cloud). The previous observation suggests that σ0stems fundamentally from the electronics response function with little contribution from the ionization cloud (whose time duration is both field and pressure dependent). This hypothesis was partly addressed for a reference case (Edrift =145.5 V/cm/bar) by using for the PSA a computing-intense fit to all pulses based on a numerical convolution of a Gaussian function with the known FEE response function (obtained from [26]), characterized by a shaping time τ. The σt,M−zMslope obtained in this way agreed with the one coming from a standard Gaussian PSA (eq. (3.1)) within 5%. The fit of the σt,M−tMcorrelation plots (as those of figure 8) to eq. (3.2) returns a slope given by q2DL v2 d without previous knowledge of the drift velocity vd. This is to be preferred to a σt,M−zM fit since it simplifies the propagation of uncertainties. Starting from the known value of the velocity vdand this slope, the longitudinal diffusion coefficient can be defined for convenience (note the √P pre-factor) as: D∗ L=r2PDL vdµm √cm ×√bar (3.4) and analogously for the transverse diffusion coefficient. The spatial spread of a point-like ionization cloud propagating along a distance zcan be obtained after this definition as: σL,T=D∗ L,T √z √P(3.5) Except for the definition used in eq. (3.4), this analysis resembles the one previously followed in [6,8]. The reason for this particular choice relies on the fact that D∗ L,Tcan be expected to depend on E/Palone in virtue of an approximate scaling law (rigurously exact in the termal limit), and this allows a direct comparison with measurements taken at higher pressures (e.g. 10 bar) in other NEXT prototypes. For pure Xenon in the pressure regime 1–10 bar support for this scaling can be found in [27,28] (DT) and [6,8,29] (DL), as long as Edrift/P>12.5 V/cm/bar, that comfortably – 14 –
2014 JINST 9 C04015 0 5 10 15 20 25 30 35 1 1.25 1.5 1.75 2 2.25 2.5 2.75 3 zM [cm] σt,M [µs] Xe/TMA (97.8/2.2), Edrift/P=66.6 V/cm/bar, P=1.0 bar Xe/TMA (97.8/2.2), Edrift/P=93.0 V/cm/bar, P=1.0 bar Xe/TMA (97.8/2.2), Edrift/P=119.2 V/cm/bar, P=1.0 bar Xe/TMA (97.8/2.2), Edrift/P=145.5 V/cm/bar, P=1.0 bar Xe/TMA (97.8/2.2), Edrift/P=164.0 V/cm/bar, P=1.0 bar Xe/TMA (97.6/2.4), Edrift/P=103.6 V/cm/bar, P=2.7 bar 0 5 10 15 20 25 30 35 0.65 0.7 0.75 0.8 0.85 0.9 0.95 1 zM [cm] εM/εevt Figure 10. Left: width-time correlation in z-slices for all runs used in this section. Right: highest charge fraction contained in a single pixel for a 30 keV event as a function of the position of the charge deposit within the drift region. The decreasing trend towards high zvalues indicates the presence of transverse diffusion: the highest reduction seen for about the highest field, the lowest reduction seen for the highest pressure (nearly flat), following the behaviour shown in left figure. For increased clarity only 3 data sets are shown. contains the range of interest for NEXT. It is later shown that it represents indeed a reasonable scaling law for Xe/TMA mixtures up to 2.7 bar, also. It must be noted in pass that DLderived at high pressures from recent experiments with α-particles in [30] is at odds with the aforementioned works for Edrift/P>12.5 V/cm/bar, although in the authors words ‘further detailed studies will be needed’ [31]. Besides the longitudinal diffusion, the transverse diffusion coefficient D∗ Tcan be a priori studied thanks to the fine pixelated readout of the TPC. However, the observed pixel multiplicity of 2–4 (figure 5) for 30 keV energy deposits complicates the standard analysis based on a barycenter calculation. In order to illustrate the trend we chose to study the behaviour, as a function of the drift distance, of the highest charge fraction per pixel εM/εevt (figure 10-right). A high purity sample was provided by applying a width-time correlation cut (figure 8-left) to remove the biasing contribution of random coincidences. The average value of εM/εevt is indeed reduced as a function of the distance to the readout plane as expected from the increased transverse diffusion. This observable, being the ratio of two charges, is immune to attachment and is not sensitive to longitudinal diffusion. The trends show how the transverse size of the ionization cloud decreases with pressure, as given by eq. (3.5), and increases with the drift field similarly to the behaviour of the longitudinal diffusion in this range of reduced fields and TMA admixtures. The compilation of the drift velocity and longitudinal diffusion coefficient obtained in this work is given in figure 11 and table 3. For the longitudinal diffusion coefficient the statistical uncertainty of the fit to eq. (3.2) is typically 1%, to be added to the uncertainty in the drift velocity (5%) propagated through eqs. (3.2) and (3.4), and 5% from the reported difference between different PSA methods, adding to about 5.5%. We assign a 2% uncertainty to the estimate of the reduced field (smaller than the data points), arising from the sum in quadrature of the accuracy of the pressure gauge (∼1%) and the present mechanical accuracy in the definition of the drift region (1.7%). The statistical uncertainty in the TMA concentration, obtained from a dedicated calibration – 15 –
2014 JINST 9 C04015 101102103 0.1 1 Edrift/P [V/cm/bar] vd [cm/µs] 500 1000 1500 2000 DL *[µm/cm0.5×bar0.5] 25 50 75 100 125 150 175 200 0 1000 2000 3000 4000 Edrift/P [V/cm/bar] DT *[µm/cm0.5×bar0.5] Xe/TMA(97.8/2.2) Xe/TMA(99.1/0.9) pure Xenon pure TMA Xe/TMA(99.9/0.1) this work, this work, Ref. [17], D. C. Herrera et al., Ref. [17], D. C. Herrera et al., Ref. [6], NEXT−DBDM, Ref. [33], NEXT−DEMO, Ref. [27], S. Kobayashi et al., Ref. [32], S. R. Hunter et al., Ref. [29], H. Kusano et al., Ref. [28], T. Koizumi et al., Ref. [18], L. G. Christophorou et al., data simulation (Magboltz 10.0.1, P=1.0bar) P=1bar, pure Xe P=10bar, pure Xe P=10bar, pure Xe P=10bar, pure Xe P=4−6bar, Xe/TMA(97.8/2.2) P<1bar, pure TMA P=1bar, pure Xe P=3−6bar, pure Xe P=3−6bar, Xe/TMA(99.1/0.9) P=1.0bar, Xe/TMA(97.8/2.2) P=2.7bar, Xe/TMA(97.6/2.4) Figure 11. Left: world-compilation of drift velocity data for Xe/TMA mixtures including the results from the present work (full red circles, star).(Note: blue triangles have been obtained in an analysis performed after publication of [17]). Right: longitudinal and transverse diffusion, for which only data from pure Xenon and from the present work are available. The estimate of the transverse diffusion is based on the approximate method discussed in section 4, for which only statistical uncertainties are given (smaller than the data points). All measurements have been taken (or extrapolated, using ideal gas law) to 20◦C. Magboltz simulation performed at 20◦C and 1 atm. of the mass spectrometer with known Xe/TMA proportions, is 2% (relative, hence 2.20%±0.04% typically). Systematic uncertainties in the calibrating/measuring procedure were assessed by performing measurements of identical admixtures under different conditions (history, input pressure at the capillary and mixing procedure). The maximum relative deviation found was 10%, that can be interpreted as the present systematic uncertainty on the TMA estimate. Figure 11 includes the latest Magboltz (v10.0.1) microscopic simulations [34] (performed at P=1013 mbar and T=20◦C), that are seen to provide a reasonable description of Xe/TMA data at 1 bar as well as 2.7 bar after the √Pscaling of DL,T. The agreement with Magboltz can be – 16 –
2014 JINST 9 C04015 further improved by artificially decreasing the TMA concentration from 2.2% to 1.4%, seemingly well beyond the experimental uncertainty of our mass spectrometer. On the other hand, a simultaneous description of vdand D∗ Lwithin the reported uncertainties does not seem to be possible with Magboltz at the moment even if leaving the TMA concentration free. It must be noted that, in simulation, the overall level of uncertainty of the TMA characterization at low fields is dominated by the (unknown) inelastic cross-section. It is very suggestive that the present best guess for the latter has an estimated uncertainty around 20% [35] thus at the same level than the reported 30% effect. A reduction of the longitudinal diffusion coefficient in Xe/TMA (97.8/2.2) by a factor 2-3 relative to that in pure Xenon can be clearly observed in figure 11-right, besides showing an increasing trend with field (contrary to pure Xenon). According to Magboltz the transverse diffusion may be reduced up to a factor 10 in Xe/TMA mixtures. The increasing behaviour seen in simulation as a function of the electric field as well as the decreasing behaviour with pressure are qualitatively observed in our data (figure 10-right). Figure 11 shows also for illustration a quantitative estimate of the transverse diffusion coefficient as obtained from a simplified analytical description of the behaviour of the magnitude εM/εevt (see next section for details). Notably, and contrary to the general behaviour expected for quenched noble gases, at the intended fields in the NEXT experiment (Edrift/P=25-100 V/cm/bar) the addition of TMA can modestly reduce the drift velocity relative to that of pure Xenon for 1%TMA admixtures, while DLcan exceed the values for pure Xenon in 0.1%TMA ones. Generally, diffusion-wise, the best characteristics of the Xe/TMA mixture in the Edrift/P=25-100 V/cm/bar range are found for ∼1 %TMA admixtures or beyond. For completeness, figure 11 conveys results from the works [27–29,32] for pure Xenon to illustrate the approximate pressure-independence of the chosen observables in the pressure regime 1–10 bar. The coefficients as presented in [27,28] have been translated to the ones used here by resorting to the values of vdin [32]. A large independency from the operating pressure can be inferred for vd,D∗ Land D∗ Talso for Xe-TMA mixtures in this pressure and drift field regime. A detailed discussion of this type of scalings requires considering compressibility factors Z(both neglected in simulation and when adapting data from [27–29,32]), however for Xenon it generally represents a sub-5% correction in this pressure range and therefore the simpler ideal gas law has been used. 3.4 Attachment coefficient in Xe/TMA mixtures The attachment coefficient of the gas mixture can be obtained from the behaviour of the event charge/energy as a function of the drift position zM, obtained once random coincidences have been subtracted in order to enhance the sample purity (figure 8). Therefore, the z-position was sliced and a Gaussian fit in the 30 keV region performed for each slice, resulting in the data sets shown in figure 12 for two typical cases. An exponential fit yields attachment coefficients of the order of 10% per meter, showing little dependence with the operating pressure and field. This figure, likely dominated by impurities in the present system, sets an important upper bound to Xe/TMA mixtures whose attachment properties are not known. The (tolerable) 10% observed effect sets an important benchmark value for the usability of Xe/TMA mixtures in m-scale experiments as NEXT-100. A compilation of the attachment coefficients together with the fit errors is given in table 3. – 17 –
2014 JINST 9 C04015 0 5 10 15 20 25 30 35 26 27 28 29 30 31 zM [cm] εevt [keV] Edrift/P=66.6 V/cm/bar, P=1bar Edrift/P=103.6 V/cm/bar, P=2.7bar Figure 12. Charge loss as a function of the drift distance for typical drit fields at P=1 bar (2.2% TMA), squares, and P=2.7 bar (2.4% TMA), circles. The trend is fitted to an exponential law that allows extracting the attachment coefficient. The data has been up-scaled by ∼5% relative to the energy calibration procedure described in the text (that does not use zinformation at the moment), in order to provide agreement at z=0 with the known escape peak energy. Table 3. Table with some parameters for Xe/TMA mixtures extracted from this work. The dominant source of the reported uncertainties is systematic, within the range 2.0–5.5%, except for ηwhere uncertainties proceed from the fit. The relative uncertainty in the TMA concentration is 2%(sta) and 10%(sys), the accuracy of the pressure gauge is 10 mbar. The pressures reported correspond to about 20◦C with a maximum 5◦C uncertainty. Although we attribute the observed attachment to impurities, it can be interpreted as an upper bound to the one inherent to the Xe/TMA mixture. E/P[V/cm/bar] vd[cm/µs] D∗ L[µm/√cm ×√bar] η[m−1] TMA(%) P[bar] 66.6±1.3 0.097 ±0.005 340 ±19 0.10 ±0.01 2.2 1.0 93.0±1.9 0.151 ±0.007 368 ±20 0.08 ±0.02 2.2 1.0 119.2±2.4 0.227 ±0.011 456 ±25 0.08 ±0.01 2.2 1.0 145.5±2.9 0.345 ±0.017 579 ±32 0.10 ±0.01 2.2 1.0 164.0±3.3 0.442 ±0.022 649 ±36 0.07 ±0.04 2.2 1.0 103.6±2.1 0.179 ±0.009 351 ±18 0.14 ±0.01 2.4 2.7 4 Discussion A full experimental characterization of the dynamics of the primary electron cloud needs of a quantitative estimate of the diffusion coefficient in the direction perpendicular to the electric field, D∗ T. It must be noted that according to simulation the transverse diffusion coefficient in present conditions is of the order of D∗ T=250 µm/√cm ×√bar (figure 11, red line). Therefore, the anticipated radial width of a point-like electron cloud is 1.5(0.94) mm for 1(2.7) bar when bridging the full anode-cathode distance, considerably smaller than the pixel size of the readout plane. On top of this difficulty, the initial size of the ionization cloud stemming from ∼30keV γinteractions needs to be considered, provided it is expected to be also at the mm-scale (table 2). – 18 –
2014 JINST 9 C04015 We tentatively use here a simple method to estimate the transverse diffusion coefficient for cases where the typical charge spread is considerably smaller than the pixel size, a condition that makes a standard analysis based on a barycenter calculation particularly difficult. The main strength of the approach is that it does not rely on simulation and it is based on a simple parameterization of the ratio εM/εevt earlier defined, namely, the highest charge fraction contained in a single pixel as a function of the drift distance. The starting point of the method is the expression for the average behaviour of this observable in the absence of instrumental effects: <εM εevt >=1 LZL/2 −L/2 dxZL/2 −L/2 1 √2πˆvr e−(x−x0)2 2ˆvrdx02 (4.1) where L=8mm is the pixel side and ˆvrstands for the transverse (radial) variance of the cloud: ˆvr=D∗ T 2×zM P+ˆvr,0(4.2) The effect introduced by the initial electron cloud is therefore contained in ˆvr,0. The square in eq. (4.1) reflects the fact that the double-integral over the 2 dimensions of the pixel (x,y) factors out in two equal pieces. The solution to eq. (4.1) simply reads: <εM εevt >=2ˆvre−L2 2ˆvr−1+√2πL√ˆvrerfL √2ˆvr2 2πL2ˆvr (4.3) A 2-parameter fit to the experimental values of <εM εevt >returns D∗ Tand ˆvr,0. Two exemplary cases for high and low pressure are shown in figure 13-left for Edrift/P=103.6 V/cm/bar at 2.7 bar (points), and for Edrift/P=145.5 V/cm/bar at 1 bar (crosses). The fit returns the following values: D∗ T/√P=125±10 µm/√cm, pˆvr,0=0.49±0.03 mm (2.7 bar) and D∗ T/√P=300±10 µm/√cm, pˆvr,0=1.01 ±0.02 mm (1 bar). The overall results from the fit to all available data are shown in figure 13-right with only statistical uncertainties (as derived from the weighted fit) shown, and compared with Magboltz simulations. In line with the previous observations for vdand D∗ Lan approximate agreement is found, improving if slightly increasing the TMA concentration in simulation. Some caveats are worth being noted at this point: the initial transverse size of the ionization cloud ˆvr,0is expected to be independent from the drift field, however up to 20% deviations are observed in the fitted data, well above the statistical uncertainty. At 1 bar, this magnitude averaged over all drift fields is pˆvr,0(1bar) = 1.0±0.1 mm, considerably smaller than the csda range (assuming straight propagation) expected from table 2. This value is within a factor of 2 of the one extracted at 2.7 bar, showing a scaling behaviour somewhere in between 1/Pand 1/√P, a fact difficult to assess without a detailed microscopic simulation. On another hand, the values for the electron cloud obtained from inspection of the intercepts in the σt,M−zMcorrelation curve (figure 10-left) slightly differ from this analysis: pˆvz,0=qσ2 0−σ2 0,FEE ×vd(4.4) Taking as an estimate for σ0,FEE =1.15 µs (the smallest intercept observed in data) and using the σ0 measured at the lowest field returns pˆvz,0(1bar) = 0.6 mm, about 40% smaller than the result from – 19 –
2014 JINST 9 C04015 0 5 10 15 20 25 30 35 0.55 0.6 0.65 0.7 0.75 0.8 0.85 0.9 0.95 1 zM [cm] εM/εevt × 0.8 × 1.2 × 0.8 × 1.2 DT*/P0.5 = 300 µm/cm0.5 DT*/P0.5 = 125 µm/cm0.5 40 60 80 100 120 140 160 180 200 150 200 250 300 350 400 450 500 Edrift/P [V/cm/bar] DT *[µm/cm0.5 × bar0.5] this work, P=1.0bar, Xe/TMA(97.8/2.2) this work, P=2.7bar, Xe/TMA(97.6/2.4) Magboltz 10.0.1, Xe/TMA(97.8/2.2) Figure 13. Left: behaviour of the highest charge fraction contained in a single pixel εM/εevt as a function of the z-position of the deposit for Edrift/P=145.5 V/cm/bar at P=1 bar (crosses) and Edrift/P= 103.6 V/cm/bar at P=2.7 bar (points). The transverse diffusion coefficients extracted from the fit proposed in the text are indicated together with the trends for 20% variations around it, to illustrate the sensitivity of the method. Right: transverse diffusion coefficient obtained from this analysis including statistical uncertainties only. Systematic effects related to the naive treatment of the initial ionization cloud have not been evaluated. the transverse analysis. Despite these potential biasing effects not being accounted for, the present analysis seems to soundly set a scale for the transverse coefficient D∗ T∼250-300 µm/√cm×√bar in the reduced field range Edrift/P=50-200 V/cm/bar for ∼2 %TMA admixtures, largely pressureindependent on account of the expected 1/√Pscaling of DT. It should be mentioned that a new simulation software (Degrad) has been recently developed by S. Biagi in order to calculate the spatial distribution of electron clouds stemming from X-ray interactions in gases [34], so in principle it should be possible to accurately evaluate the proposed method (based on eq. (4.1)) against simulation in the near future, as well as using bench-marking reference data to allow for a more accurate determination of D∗ T. During the peer-reviewing of this work, it became known to us that this software provides a value for pˆvz,0(1bar) = 0.617 ± 0.005 mm in Xenon at 1 bar for 30 keV electrons, with a distribution largely Gaussian [36]. This preliminary result is in good agreement with the aforementioned values and about a factor 10 less than the Rcsda, confirming the localized nature of the charge deposits used in this analysis. 5 Conclusions Several system aspects of a 70 l high pressure Xenon TPC operated with a microbulk Micromegas readout plane have been presented. The TPC was operated under low energy γrays with energies around the characteristic Xenon Kα,βemission (30 keV), collecting about 2.4×106events. Apart from a temporary technical problem affecting one quadrant, the TPC achieved an energy resolution after calibration of 10.6% FWHM(1 bar) and 12.5% FWHM(2.7 bar) over its entire active volume (∼25 l). Inter-quadrant gain variations around 10% were observed, while the inter-pixel gain spread stayed within 20%, underlining the excellent uniformity of response of this type of readouts when aiming at large area coverage (700cm2in this case). No special issues related to – 20 –
2014 JINST 9 C04015 the pressure increase were observed except for a 25% reduction of the workable gain at 2.7 bar (m=1.6×103). The chamber has been conceived for operation under high energy γ’s at 10 bar, a step that is currently being preceded by an upgrade of the gas system. For the first time the longitudinal diffusion coefficient in Xe/TMA mixtures has been extracted, in particular for a 2.2% TMA admixture. A reduction of its value by about ×2-3 with respect to pure Xenon was observed in the 50–100 V/cm/bar reduced drift field regime, roughly as expected from microscopic modeling (Magboltz v10.0.1). On the other hand, the qualitative behaviour observed for the transverse diffusion coefficient agrees with the one obtained from Magboltz (that anticipates a reduction by a factor 10) and indeed a pressure-normalized value at the ∼250-300 µm/√cm ×√bar level as predicted by simulation is strongly hinted by present data. No evidence of strong pressure dependence was observed for the pressure-normalized coefficients. A significant improvement of the 2-blob topological signature in the ββ0 decay of 136Xe is not guaranteed by the reduced diffusion and requires further studies, but its potential makes the case appealing. Generally, diffusion-wise, the best characteristics for Xe/TMA mixtures in the Edrift/P=25-100 V/cm/bar range are found for ∼1% TMA admixtures or beyond, however it is necessary to verify that such TMA concentrations are compatible with the fluorescence yields and Penning transfer rates required for 0νββ searches, and this is currently under investigation. The observed attachment coefficient is little dependent on pressure and electric field, showing values around 10% for a 1 meter electron drift (correspondingly, 10.0±1.1ms electron life-time for the lowest reduced field studied Edrift/P=66.6 V/cm/bar). This level is presumably dominated by impurities in the gas and hence it should be interpreted as an upper bound to the attachment inherently coming from the Xe/TMA mixture. In the seemingly unlikely case that such an upper bound would be saturated, a 1 m scale experiment (as NEXT-100) could still make use of it at a very mild charge loss if Xe/TMA finally proves to be a golden combination for this type of physics. Acknowledgments NEXT is supported by the following agencies and institutions: the Ministerio de Econom´ ıa y Competitividad (MINECO) of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04-04 and FIS2012-37947-C04; the Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02- 05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, projects PTDC/FIS/103860/2008 and PTDC/FIS/112272/2009. J. Renner (LBNL) acknowledges the support of a US DOE NNSA Stewardship Science Graduate Fellowship under contract no. DE-FC52- 08NA28752. The development of NEXT-MM in particular has important contributions from the European Research Council T-REX Starting Grant ref. ERC-2009-StG-240054 of the IDEAS program of the 7th EU Framework Program; and also MINECO under grants FPA2008-03456, FPA2011-24058 and CPAN under grant CSD2007- 00042. This work would not have been possible without the encouragement of our RD51 colleages and the dedicated effort of R. de Oliveira and his team at CERN to provide these unique detectors. Discussions with O. Sahin, R. Veenhof, S. Biagi and C. Acevedo are greatly acknowledged. DGD gratefully acknowledges the ‘Charpak award’ for this work. – 21 –