Evaluation of patient visual comfort and repeatability of refractive values in non-presbyopic healthy eyes

Segura, F.; Lopez de la Fuente, C; Pinilla, I.; Fuentes-Broto, L.; Sanchez-Cano, A.

Abstract

•AIM: To evaluate the intra-operator repeatability in healthy subjects using the WAM-5500 auto-kerato/refractometer and the iTrace aberrometer, to compare the refractive values and the subjective refraction obtained with both devices and to determine which of these three spherocylindrical corrections allows the subject to achieve the best visual comfort. •METHODS: Forty-two non-presbyopic healthy eyes of 42 subjects were enrolled in this prospective study. Refractive values were compared, evaluating the repeatability, the relationship between the methods and the best visual comfort obtained. •RESULTS: Sphere, cylinder and axis results showed good intraclass correlation coefficients (ICC); the highest ICC was obtained using the spherical refraction with the autorefractometer and the aberrometer, achieving levels of 0.999 and 0.998, respectively. The power vector (PV) was calculated for each refraction method, and the results indicated that there were no statistically significant differences between them (P>0.05). Direct comparison of PV measurements using the three methods showed that aberrometer refraction gave the highest values, followed by the subjective values; the autorefractometer gave the lowest values. The subjective method correction was most frequently chosen as the first selection. Equal values were found for the autorefractometer and the aberrometer as the second selection. •CONCLUSION: The iTrace aberrometer and the WAM-5500 auto-kerato/refractometer showed high levels of repeatability in healthy eyes. Refractive corrections with the aberrometer, the autorefractometer and subjective methods presented similar results, but spherocylindrical subjective correction was the most frequently selected option. These technologies can be used as complements in refractive evaluation, but they should not replace subjective refraction. Segura, F.; Sanchez-Cano, A.; Lopez de la Fuente, C; Fuentes-Broto, L.; Pinilla, I.

Full text

陨灶贼允韵责澡贼澡葬造皂燥造熏灾燥造援 8熏晕燥援 5熏Oct.18, 圆园15 www.IJO.cn 栽藻造押8629原愿圆圆源缘员苑圆 8629-82210956 耘皂葬蚤造押ijopress岳员远猿援糟燥皂 Evaluationofpatientvisualcomfortandrepeatabilityof refractivevaluesinnon-presbyopichealthyeyes 窑ClinicalResearch窑 1DepartmentofSurgery,GynaecologyandObstetrics, UniversityofZaragoza,Zaragoza50009,Spain 2AragonHealthSciencesInstitute,UniversityofZaragoza, Zaragoza50009,Spain 3DepartmentofAppliedPhysics,UniversityofZaragoza, Zaragoza50009,Spain 4DepartmentofPhysiologyandPharmacology,Universityof Zaragoza,Zaragoza50009,Spain 5DepartmentofOphthalmology,LozanoBlesaUniversity Hospital,Zaragoza50009,Spain Correspondence to: IsabelPinilla. Departmentof Ophthalmology,UniversityofZaragoza,C/PedroCerbuna, 12,Zaragoza50009,[email protected] Received:2014-05-20 Accepted:2015-02-15 Abstract ·AIM:Toevaluatetheintra-operatorrepeatabilityin healthysubjectsusingtheWAM-5500auto-kerato/ refractometerandtheiTraceaberrometer,tocomparethe refractivevaluesandthesubjectiverefractionobtained withbothdevicesandtodeterminewhichofthesethree spherocylindrical corrections allows the subject to achievethebestvisualcomfort. ·METHODS:Forty-twonon-presbyopichealthyeyesof 42subjectswereenrolledinthisprospectivestudy. Refractive values were compared, evaluating the repeatability,therelationshipbetweenthemethodsand thebestvisualcomfortobtained. ·RESULTS:Sphere,cylinderandaxisresultsshowed goodintraclasscorrelationcoefficients(ICC);thehighest ICCwasobtainedusingthesphericalrefractionwiththe autorefractometerandtheaberrometer,achievinglevels of0.999and0.998,respectively.Thepowervector(PV) wascalculatedforeachrefractionmethod,andthe results indicated that there were no statistically significantdifferencesbetweenthem ( >0.05).Direct comparison of PV measurements using the three methodsshowedthataberrometerrefractiongavethe highestvalues,followedbythesubjectivevalues;the autorefractometergavethelowestvalues.Thesubjective methodcorrectionwasmostfrequentlychosenasthe first selection. Equal values were found for the autorefractometerandtheaberrometerasthesecond selection. ·CONCLUSION:TheiTraceaberrometerandtheWAM- 5500auto-kerato/refractometershowedhighlevelsof repeatabilityinhealthyeyes.Refractivecorrectionswith theaberrometer,theautorefractometerandsubjective methodspresentedsimilarresults,butspherocylindrical subjectivecorrectionwasthemostfrequentlyselected option.Thesetechnologiescanbeusedascomplements inrefractiveevaluation,buttheyshouldnotreplace subjectiverefraction. ·KEYWORDS: repeatability; opticalcorrection; aberrometer;autorefractometer;subjectiverefraction DOI:10.3980/j.issn.2222-3959.2015.05.32 SeguraF,Sanchez-CanoA,LopezdelaFuenteC,Fuentes-BrotoL, PinillaI.Evaluationofpatientvisualcomfortandrepeatabilityof refractivevaluesinnon-presbyopichealthyeyes. 2015;8(5):1031-1036 INTRODUCTION Therearemanytechniquesforestablishingthebest opticalcorrectionofrefractionerrors.Usually,a subjectivetestisperformedfollowinganobjectivetestthat includesautorefractometryorretinoscopytodeterminethe spherocylindricalrefractionwithwhichthesubjectreaches hisbestvisualquality.Currently,measurementofvisual acuity(VA)isthemostwidespreadmethodformeasuring visualquality.Basedonthisstatement,therefractionthat allowsthesubjecttoreachhismaximumVAisconsidered thebestcorrection. Inrecentyears,advancesintechnologyhaveallowedthe commercialisationofsophisticatedinstrumentstomeasure objectiverefractioninclinicaluse.Inthisstudy,araytracing aberrometer(iTrace 誖,TraceyTechnologies,Houston, Texas, USA)andan openviewautorefractometer (WAM-5500 誖autokerato/refractometer,GrandSeikoCo. Ltd.,Japan)wereused.Previousstudieshavefocusedon discoveringifthese objectiveinstrumentscanreplace VA-basedsubjectiverefraction [1-8].Thepatient'ssubjective visualachievementshouldbeevaluated. 1031 Theaimsofthisstudyweretoevaluatetheintra-operator repeatabilityinhealthysubjectsusingtheWAM-5500 auto-kerato/refractometerandtheiTraceaberrometerto comparetherefractivevaluesobtainedwithbothdevicesand withsubjectiverefractionandtodeterminatewhichofthese three spherocylindrical corrections(obtainedfrom autorefractometer,aberrometerorsubjectivetest)allowsthe subjecttoachievethebestvisualcomfort. SUBJECTSANDMETHODS WAM-5500Auto-kerato/refractometer TheWAM-5500 auto-kerato/refractometerisanopen-viewinstrumentthat usesatwo-stepmethodforcalculatingtherefractiveerror[4,5]. First,threeinfraredlightarchesareprojectedintotheretina. Second,thereflectedlightfromtheretinapassesthrougha lenssystem(Badaloptometer)thatmovesquicklytofocus theimage.ThefinalpositionoftheBadaloptometerallows automaticsoftwaretodeterminetherefractionofthe examinedeye.Theuseofthreearcsallowsmeasurements whenthepupildiameterisreduced,withaminimumof2.3mm. Thisistheminimumpupilsizeanalysedbytheinstrumentto determinetherefractionofthestudiedeye.Thisinstrument hassignificantadvantages.Itsopen-viewconditionallows morenaturalmeasurementoftherefraction.Itisalsoableto simultaneouslymeasuretherefraction(sphericalequivalent) andthepupildiameteratafrequencyof5Hz.Withthis function,wecanknowtheaccommodationfluctuationduring atimeinterval,detectaccommodationanomalies,and confirmcasesofpresbyopiaoreyestrain. iTraceAberrometer Raytracingaberrometryisbasedon measuringthepositionsoflaserbeamsprojectedintothe individualretinawhentheypassthroughtheobservedpupil indifferentdirections,butalwaysparalleltothevisual axis [9-11].Eachentrancepointthroughthepupilhasitsown projectionontheretina,andasetofentrypointsgeneratesa setofprojections.Theanalysisofretinaldisplacementofthe projectedbeamallowsestimationofthewavefrontaberration (Zernikecoefficients)oftheexaminedeye.Theinstrument alsoprovidesthespherocylindricalrefractionthatwouldbe abletocompensatefortheaberration,aswellasthepupil diameter.Theadvantagesofthedeviceareasfollows:ashort measurementtimeofapproximately300ms(althoughslower thanashackhartmann-shackaberrometer)andcontrolofthe beamprojectionbythesystem,whichcanthereforemeasure pupilsizesrangingfrom2to8mm.TheiTraceallows measurementofhighlyaberratedeyesandametropiasina rangeof 依15D. SubjectiveRefraction Aconventionalphoropterandour ownsoftwarefordisplayingoptotypesona19''TFTscreen wereusedforthemeasurementofsubjectiverefraction [12]. Theprogrammeshows,sequentiallyandrandomly, high-contrastanddifferentsizeoptotypes(VAvalues between0.02and2.8).Theprogrammeparameterscouldbe modifiedtoadapttodifferentconditionsasfollows:subject distancefromthescreen,thenumberofoptotypesshownfor eachVAvalue,therateofcorrectanswersrequiredtopassa lineofVAortheoptotypewewishedtoshow.Unlikeother optotypeprojectors,thisinstrumenthas important advantages.Theluminancevalues(250cd/m2)andcontrast (550:1)ofthescreenaremuchhigherthantheminimum requirements.Itallowsmuchmorepreciseadjustmentofthe VAandspherocylindricalrefractionofthestudiedsubject, anditallowsmorereliableresultstobeobtainedbecauseit showsrandomoptotypes,althoughtesttimeisincreased. Subjects and Experimental Procedures Forty-two non-presbyopiceyesof42subjectswereenrolledinthe study.Allof the subjectsgaveinformedconsentto participateinthestudy.Thestudywasconductedin accordancewiththetenetsoftheDeclarationofHelsinki,and theexperimentalprotocolwasapprovedbythelocalEthics CommitteeoftheAragonesHealthScienceInstitute. Inclusioncriteriawerethefollowing:agebetween18and 35y,nopresbyopiaandbest-correctedVA(BCVA)of0.5or better(accordingtotheSnellenscale).Subjectswithprevious intraocularsurgery,diabetesorothersystemicdiseases, historyofocular,congenitalorneurologicaldisease,current useofamedicationthatcouldaffectvisualfieldsensitivityor inabilitytoperformanyoftheprotocoltestswereexcluded. Allofthesubjectsunderwentanoptometricexaminationthat includedaclinicalhistoryandexaminationbyWAM-5500 auto-kerato/refractometer,iTraceaberrometerandsubjective refraction. Themeasurementsweremonocular,undernatural accommodationandpupilsize,andthetestswereperformed underlowambientlightingconditions.Theinstruments (auto-kerato/refractometerandaberrometer)werecalibrated usinganartificialeyeofknownrefractiveerror,-4.75Dfora vertexdistanceof12mm,andradiusofcurvature(7.62mm) beforethetestswereconducted,aswellastheoptotype displaysystem.Measurementconditionsweremaintainedfor theentiresampleandforallinstruments. Threerefractivemeasurementswereperformedwiththe auto-kerato/refractometerwhilethepatientwasobservinga non-accommodativestimulusplaced7mfromtheevaluated eye.Themeanofthethreemeasurementswascalculatedfor fardistance,resolutionof0.12Dand12mmofdistanceto vertex.Fluctuationinaccommodationandpupildiameter weremeasuredfor20consecutiveseconds. TheiTraceaberrometerwasusedtoperformthree measurementsofrefractionandtocollectaberrationdata underthesameconditions(stimulus,distance,numberof measurementsandresolution). Evaluationofpatientvisualcomfortinhealthyeyes 1032 陨灶贼允韵责澡贼澡葬造皂燥造熏灾燥造援 8熏晕燥援 5熏Oct.18, 圆园15 www.IJO.cn 栽藻造押8629原愿圆圆源缘员苑圆 8629-82210956 耘皂葬蚤造押ijopress岳员远猿援糟燥皂 TheBCVA ofthepatientwasdeterminedby spherocylindricalsubjectiverefraction. Tocomparethespherocylindricalcorrectionsprovidedby thethreemethods,thepowervector(PV)parameterwas used [13,14]: M=S+C 2 J0=-(C 2)·cos2琢 J45 =-(C 2)·sin2琢 PV= M2+J0 2+J45 2 姨 whereS isthevalueofthesphere,C isthevalueofthe cylinderand 琢istheangleofthecylinder. Spherocylindrical correctionsobtainedfromthethree differentmethodsweremountedinthreetrialframes.An optotype (withaVAvaluelessthanthemaximumineach case)wasprojectedonthescreen.Subjectscomparedtheir perceivedvisualqualityoftheoptotypeprojectionwiththe threedifferentprescriptions(eachonewaspresentedina randomfashionduringtenseconds).Theindividualswere askedtochooseamongthethreerefractions,givinga numericvalueof"1"totheonewithwhichtheyfeltmost comfortable,avalueof"2"tothenext,andavalueof"3"to theonewithwhichtheyfeltleastcomfortable. StatisticalAnalysis Statisticalanalyseswerecarriedout withtheStatisticalPackagefortheSocialSciences(SPSS 17.0,SPSSInc.,Chicago,IL,USA).Toassessthereliability oftherepeatedmeasurementswithbothinstruments, intraclasscorrelationcoefficients(ICC)wereused.Thisis definedastheratioofthebetween-subjectsvariancetothe sumofthe pooled within-subjectsvarianceandthe between-subjectsvariance.InterpretationoftheICC consideredslightreliabilityforvaluesbetween0and0.2,fair reliabilityforvaluesbetween0.21and0.4,moderate reliabilityforvaluesbetween0.41and0.6,substantial reliabilityforvaluesbetween0.61and0.8andalmostperfect reliabilityforICCvaluesgreaterthan0.81. Fortheinter-refractionstudy,thevaluesofeachPVobtained fromtheautorefractometer,theaberrometerandsubjective refractionwerecomparedbyanon-parametricpaired Wilcoxontest.BlandandAltman[15] plotswereusedtoassess agreement; thethreeprocedureswerecomparedby displayingthedifferencesbetweenmeasurementsbytwo methodsagainstthemeanofthetwomeasurements.The comfortlevelsamongthethreerefractionsandtheir classificationwerecompared. RESULTS Table1showstherepeatabilityfindings,andnostatistically significantdifferenceswerefoundamongrepeated measurements ( >0.05).Allmeasuredparametersshowed goodICCs,andallofthemwerehighlyrepeatablewithICCs higherthan0.88.ThehighestICCwasobtainedusingthe sphericalrefractionwiththeautorefractometerandthe aberrometer,achievinglevelsof0.999and0.998,respectively. ThePV(mean依standarddeviation)wascalculatedforeach refractionmethod,PVsub(subjective PV),PVauto (autorefractometerPV),andPVabe(aberrometerPV):PVsub 1.341 依1.560D,PVauto1.334依1.452DandPVabe1.374依 1.675D.Theresults(mean 依standarddeviation)indicated thattherewerenostatisticallysignificantdifferencesbetween PVsubandPVauto( =0.985),PVsubandPVabe( =0.480) orbetweenPVautoandPVabe( =0.587). Figures1,2and3showtheBland-AltmanplotsofPV reproducibilitybetweenthemethods.Thefiguresillustrate theagreementbetweenthePVsub,PVautoandPVabe values,andthescatterplotsdemonstratetheagreement amongthe measurements;more than90%ofthe measurementswerewithin 依0.5D.Thesedifferenceswere relatedtothePVvaluesandwerehigherinthosewithhigher totalrefractions.Insomecases,directcomparisonofPV valuesfromthethreemethodsshowedthataberrometer refractiongavethehighestvalues,followedbysubjective refraction;autorefractometerrefractiongave thelowest values. Lastly,thesubjectswereaskedfortheirpreferredchoiceof spherocylindricalcorrectiononatrialframe.Thepreference percentagesofspherocylindricalcorrectionarepresentedin Figure4.ThemeanAVmaxreachedwiththepreferred correctionwas1.28 依0.23.Thesubjectivemethodwasthe mostvaluedcorrectionasthefirstselection(62%),andthe autorefractometerwasthethird(19%).Equalvalues(43%) werefoundfortheautorefractometerandaberrometerasthe secondselection(Figure4). Table 1 ICC for three repeated measurements in healthy eyes with the WAM-5500 autorefractometer and the iTrace aberrrometer WAM-5500 iTrace Parameters (D) ICC Lower 95% CI Upper 95% CI ICC Lower 95% CI Upper 95% CI Axis 0.905 0.856 0.943 0.892 0.820 0.938 Cylinder 0.937 0.904 0.962 0.939 0.898 0.965 Sphere 0.999 0.999 0.999 0.998 0.997 0.999 ICC: Intraclass correlation coefficients; CI: Confidence interval. 1033 DISCUSSION Ourstudyfollowedproceduressimilartothosepreviously describedforassessingcorrelatedrefractivemeasurements obtainedbyaberrometer,autorefractometerandsubjective refraction [1,2,6-8,16].ThisstudysuggeststhatboththeiTrace and theWAM-5500 havesatisfactoryintraobserver reproducibilityformeasuringocularrefractioninnonpresbyopichealthysubjects;therepeatability,withanICC over0.9,wasexcellent.Differentdataontherepeatability ofrefractionmeasurementsinhealthysubjectshavebeen previouslyreported,but,toourknowledge,therehavebeen nopreviousstudiesinvestigatingthetoleranceandthe selectionofthesubjects'prescriptionsusingourstudy conditions.TheiTraceaberrometerusedinthepresent studyrecordedmorepositivePVresultsthandidsubjective refraction,andatthesametime,morepositivevaluesthan the refractometer;however,therewasnosignificant differencebetweenthem. Onthetrialframe,spherocylindricalcorrectionsobtained fromthethreedifferentmethodsweremountedinthreetrial frames.Subjectscomparedsimultaneouslytheirperceived visualqualitywiththethreedifferentprescriptionsduringa fewseconds.Thesubjectiverefractionprescriptionwas chosenmostoften,by26subjects;thesecondmost frequentlychosenwastheaberrometricprescription,by10 subjects;andtheleastfrequentlychosenwasthe autorefractometric prescription,by8subjects. Similar percentages(43%)werefoundbetweenaberrometerand autorefractometerassecondelection;theautorefractometric prescriptionwaschosenmostoftenasthirdelection,by16 subjects.Differentselectionscanbeduetolowlevelsof accommodationwhileobjectivemeasurementsweretaken. Slightchangesinvisualcomfortcanaffectthefinal refraction,butopen-fieldinstrumentscanimprovetheresults ofrefractioncomparedtoclosed-fieldonesbecausethey Figure4Preferencepercentageofspherocylindricalcorrection for the three methods (subjective, aberrometer and autorefractometer),aftersubjectscomparedtheirperceived visual quality of the optotype projection withthe three differentprescriptions(presentedinarandomfashion),taking intoaccounttheresponsesofalloftheeyes. Figure1Bland-Altmananalysisshowingthedistributionof PVdifferences(PVsub-PVauto)onthey-axisandtheaverage oftheinstrumentreadingsPVsub+PVauto)/2onthex-axis Theoverallagreementislow(mean 依1.96SD:+0.0073依0.2898D, with95%limitsofagreementbetween-0.5636and+0.5782). Figure2Bland-Altmananalysisshowingthedistributionof PVdifferences(PVsub-PVabe)onthey-axisandtheaverage oftheinstrumentreadingsPVsub+PVabe)/2onthex-axis Theoverallagreementislow(mean依1.96SD:-0.0331依0.2514D, with95%limitsofagreementbetween-0.5258and+0.4590). Figure3Bland-Altmananalysisshowingthedistributionof PVdifferences(PVauto-Pvabe)onthey-axisandtheaverage oftheinstrumentreadingsPVauto+PVabe)/2onthex-axis Theoverallagreementislow(mean 依1.96SD:-0.0404依0.3002D, with95%limitsofagreementbetween-0.6288and+0.5480). Evaluationofpatientvisualcomfortinhealthyeyes 1034 陨灶贼允韵责澡贼澡葬造皂燥造熏灾燥造援 8熏晕燥援 5熏Oct.18, 圆园15 www.IJO.cn 栽藻造押8629原愿圆圆源缘员苑圆 8629-82210956 耘皂葬蚤造押ijopress岳员远猿援糟燥皂 producelessinstrumentalmyopia [17].Thisdoesnotoccurin thesubjectivemethodsbecausetheaccommodativestateis bettercontrolled.Preferencepercentageofsubjectivemethod wasparticularlyhighinhyperopiceyes.Despitethisfact,and referringtothecharacterisationofthesample,thesubjects hadnormalfluctuationinaccommodationvalues.Some peaksoffluctuationinaccommodationwereobservedinthe rangeof0.5D,butmostofthesewereunder0.2D.The minimumvalueswereintherangeof0.075D,whichisthe averagevalueattributedto microfluctuationsof accommodation [18].Theaveragesofhigh-orderZernike aberrationcoefficientswerealsocalculatedandachieved valuesclosetozeroexceptforanormalsphericalvalueof 0.11m,androot-mean-squarevaluesweresimilarto previouslyreportedresults [19,20].Therefore,thefinalselection cannotbeattributedtointrinsiccharacteristicsofthesample. TherepeatabilityoftheiTraceaberrometerhasbeen previouslyevaluatedbyWang [21],whoreportedresults consistentwithourdata:ICCsof0.992and0.764forthe sphereandastigmatism,respectively;andbyPinero [22] whofound excellent repeatabilitywithwithin-subject standarddeviationsforthesphereequalto0.18Dand0.15D forthecylinder. PreviousversionsoftheiTracesystemhavebeenstudied, andgoodrepeatabilitywasalsofoundwithstandard deviationsforanequivalentsphereof 依0.14Dand 依0.10D [23,24]. TherepeatabilityoftheWAM-5500hasbeenevaluatedby SheppardandDavies [25] withmeanintrasessionrepeatability of0.14Dforthecylindricalcomponentand0.09Dforthe sphericalone.Theresultsofthepresentstudyarecomparable totheseotherstudiesbecausetheobtainedICCswere excellentinbothcases:0.937and0.999,respectively.Other open-fieldautorefractometershavebeen previously evaluated;thestandarddeviationoftheresultswas0.16Dor betterfortheShin-NipponSRW-5000and0.13Dorbetter fortheShin-NipponNVision-K5001,bothofwhichwere highlyrepeatable[4,5]. SheppardandDavies [25] evaluatedtheWAM-5500tofind prescriptionssimilartosubjectiverefraction.Themean sphericalcomponent(=0.77),sphericalcomponent(= 0.21)andJ45cylindricalvector( =0.92)showedsignificant differences,buttheJ0cylindricalvector(=0.01)didnot, althoughithadnoclinicalimplications.Ourresultsare consistentwiththeirfindingsbecausetheydidnotshow differencesbetweenPVsubandPVauto(=0.871). However,differenceswerefoundwhenhyperopicand myopiceyeswerestudiedseparately.Subjectiverefraction providedlowersphereandcylindervaluesinhyperopiceyes. Inmyopiceyes,theautorefractometerobtainedspherevalues thatweremorepositivethandidothermethods. Intermsofmeasurementsandinagreementwithprevious studies,the iTraceaberrometerandtheWAM-5500 autorefractometershowedhighlevelsofrepeatabilityin healthyeyes.Refractivecorrectionsfromtheaberrometer, theautorefractometerandsubjectiverefractionpresented similarresults,butspherocylindricalsubjectivecorrection wasthe most selectedoption.In conclusion,these technologiescanbeusedascomplementstorefractive evaluationbutshouldnotreplacesubjectiverefraction. ACKNOWLEDGEMENTS WethankJ.M.Bueno,PhD(UniversityofMurcia),E.Pailos, PhD(UniversityofSantiagodeCompostela),andJ.Ares, PhD (UniversityofZaragoza)forprovidinghelpful suggestionstotheresearch. Foundations: SupportedbytheGovernmentofAragon, GroupB99;FundofHealthResearchfromInstituteofHealth CarlosIII(SpanishMinistryofHealth)PS0901854and PI13/01124;UniversityofZaragozagrant FPUZ-2011- BIO-02. ConflictsofInterest:SeguraF,None; Sanchez-CanoA, None; LopezdelaFuenteC,None; Fuentes-BrotoL, None; PinillaI,None. REFERENCES 1PesudovsK,ParkerKE,ChengH,ApplegateRA.Theprecisionof wavefrontrefractioncomparedtosubjectiverefractionandautorefraction. 2007;84(5):387-392 2CooperJ,CitekK,FeldmanJM.Comparisonofrefractiveerror measurementsinadultswithZ-viewaberrometer,humphreyautorefractor, andsubjectiverefraction. 2011;82(4):231-240 3JinabhaiA,O'DonnellC,RadhakrishnanH.Acomparisonbetween subjectiverefractionandaberrometry-derivedrefractioninkeratoconus patientsandcontrolsubjects. 2010;35(8):703-714 4MallenEA,WolffsohnJS,GilmartinB,TsujimuraS.Clinicalevaluation oftheshin-nipponSRW-5000autorefractorinadults. 2001;21(2):101-107 5DaviesLN,MallenEA,WolffsohnJS,GilmartinB.Clinicalevaluationof theshin-nipponNVision-K5001/GrandSeikoWR-5100Kautorefractor. 2003;80(4):320-324 6TangWC,TangYY,LamCS.Howrepresentativeisthe'representative value'ofrefractionprovidedbytheShin-NipponNVision-K5001 autorefractor? 2014;34(1):89-93 7McGinnigleS,NarooSA,EperjesiF.Evaluationoftheauto-refraction functionoftheNidekOPD-ScanIII. 2014;97(2):160-163 8LowryEA,LuiR,EnanoriaW,KeenanJ,deAlbaCampomanesAG. RepeatRetinomaxscreeningchangespositivepredictivevalue. 2014;18(1):45-49 9MolebnyVV,PallikarisIG,NaoumidisLP,ChyzhIH,MolebnySV, SokurenkoVM.Retinaray-tracingtechniqueforeye-refractionmapping. 1997;2971:175-183 10MolebnyVV,PanagopoulouSI,MolebnySV,WakilYS,Pallikaris IG.Principlesofraytracingaberrometry. 2000;16(5): S572-575 1035 11KruegerR.Wavefrontcustomizedvisualcorrection,thequestforsuper visionII.2004 12DalimierE,PailosE,RiveraR,NavarroR.Experimentalvalidationofa bayesianmodelofvisualacuity. 2009;9(7):12 13HarrisWF.Testinghypothesesondioptricpower. 1992; 69(11):835-845 14ThibosLN,WheelerW,HornerD.Powervectors:Anapplicationof fourieranalysistothedescriptionandstatisticalanalysisofrefractiveerror. 1997;74(6):367-375 15BlandJM,AltmanDG.Statisticalmethodsforassessingagreement betweentwomethodsofclinicalmeasurement. 1986;1(8476): 307-310 16MartinezAA,PandianA,SankaridurgP,RoseK,HuynhSC,MitchellP. Comparisonofaberrometerandautorefractormeasuresofrefractiveerrorin children. 2006;83(11):811-817 17WanXH,LinZ,CaiXG,QiaoLY,YangXD,WangNL,LiangYB. Comparisonbetweenbinocular,open-fieldautoref/keratometerand conventionalautorefractor. 2012;48(6):519-523 18ArnulfA,SantamariaJ,BescosJ.Acinematographicmethodforthe dynamicstudyoftheimageformationbythehumaneye.microfluctuations oftheaccommodation. 1981;12:123-128 19ThibosLN,HongX,BradleyA,ChengX.Statisticalvariationof aberrationstructureandimagequalityinanormalpopulationofhealthy eyes. 2002;19(12):2329-2348 20PorterJ,GuiraoA,CoxIG,WilliamsDR.Monochromaticaberrationsof thehumaneyeinalargepopulation. 2001;18(8):1793-1803 21WangL,WangN,KochDD.Evaluationofrefractiveerror measurementsoftheWaveScanWaveFrontsystemandthetraceywavefront aberrometer. 2003;29(5):970-979 22PineroDP,Sanchez-PerezPJ,AlioJL.Repeatabilityofmeasurements obtainedwitharaytracingaberrometer. 2011;88(9): 1099-1105 23PallikarisIG,PanagopoulouSI,MolebnyVV.Clinicalexperiencewith thetraceytechnologywavefrontdevice. 2000;16(5): S588-591 24WangL,MisraM,PallikarisIG,KochDD.Comparisonofaray-tracing refractometer,autorefractor,andcomputerizedvideokeratographyin measuringpseudophakiceyes. 2002;28(2): 276-282 25SheppardAL,DaviesLN.Clinicalevaluationofthegrandseikoauto ref/keratometerWAM-5500. 2010;30(2):143-151 Evaluationofpatientvisualcomfortinhealthyeyes 1036