scieee AI-readable full text Open interactive document viewer

Fire behaviour of a mortar with different mass fractions of phase change material for use in radiant floor systems

Haurie, L.; Delgado, M.; Zalba, B.; Mazo, J.

Abstract

The present work focuses on the reaction to fire of a cement mortar containing Phase Change Material (PCM), which is embedded in a lightweight aggregate, for buildings. Several samples containing different PCM mass fractions have been prepared and tested in order to study the influence of the quantity of PCM on fire behaviour. The enthalpy-temperature of the PCM curve has been measured using the T-history method, and the effect of the PCM on the thermal behaviour of the cement mortar material has been studied using an experimental setup. With the aim of characterising the reaction of the composite material to fire, various small scale laboratory tests have been carried out, paying special attention to the production of burning drops during combustion, smoke release and flame persistence. Haurie, L.; Mazo, J.; Delgado, M.; Zalba, B.

Full text

Title Fire behaviour of a mortar with different mass fractions of phase change material for use in radiant floor systems Authors Laia Hauriea*, Javier Mazob, Mónica Delgadob, Belén Zalbab aDepartment of Architectural Technology II, Universitat Politècnica de Catalunya, Av.Dr. Marañón 44-50, 08028 Barcelona, Spain bAragón Institute for Engineering Research (I3A), Thermal Engineering and Energy Systems Group, University of Zaragoza Agustín Betancourt Building, C/María de Luna 3, 50018 Zaragoza, Spain * Corresponding Author, [email protected] Email addresses: laia.haur[email protected]u (Laia Haurie), [email protected] (Javier Mazo), [email protected] (Mónica Delgado), [email protected] (Belén Zalba). Abstract The present work focuses on the reaction to fire of a cement mortar containing Phase Change Material (PCM), which is embedded in a lightweight aggregate, for buildings. Several samples containing different PCM mass fractions have been prepared and tested in order to study the influence of the quantity of PCM on fire behaviour. The enthalpy-temperature of the PCM curve has been measured using the T-history method, and the effect of the PCM on the thermal behaviour of the cement mortar material has been studied using an experimental setup. With the aim of characterising the reaction of the composite material to fire, various small scale laboratory tests have been carried out, paying special attention to the production of burning drops during combustion, smoke release and flame persistence. Nomenclature Fo Fourier number HDPE High-density polyethylene *Manuscript Click here to view linked References HRR Heat released rate [W/g] L Thickness of the mortar samples [m] m Exponential decay constant m [s-1] PCFC Pyrolysis combustion flow calorimeter PCM Phase Change Material Pt Platinum T∞ Air flow temperature [ºC] T1 External temperature of the mortar samples in the thermal diffusivity tests [ºC] T2 Intermediate temperature of the mortar samples in the thermal diffusivity tests [ºC] T3 Internal temperature of the mortar samples in the thermal diffusivity tests [ºC] Tini Initial temperature of the mortar samples in the thermal diffusivity tests [ºC] TGA Thermogravimetric analysis TTI Time to ignition [s] t Time [s, min] Greek symbols α Thermal diffusivity [mm2·s] ξ1 First eigenvalue of heat transfer differential equation 1. Introduction Phase change materials (PCMs) can be used to improve the energy efficiency of buildings as well as provide thermal comfort to their occupants. There are several diverse applications of PCMs in the building sector. PCMs can be incorporated in building envelopes, increasing their thermal inertia and reducing the fluctuation of the interior temperature of the building and therefore its thermal load. This is known as a passive application. These PCMs can also be part of the active installations of heating and cooling systems. Their storage capacity can be exploited to make it easier the use of energies of intermittent availability. PCMs can be incorporated into building elements by their integration into conventional building materials. The main PCM materials used in buildings are composites of PCM and gypsum, composites of PCM and polymers, and composites of PCM and cement. Concrete elements have a high thermal mass in buildings. PCMs can be used to enhance this thermal mass with the objective of improving the thermal behaviour of buildings. Several techniques for incorporating PCMs in cement composite materials have been studied in the literature. PCM can be soaked into concrete blocks by an immersion process [1,2]. Due to the low porosity of concrete, the maximum amount of PCM that can be absorbed is around 5% in mass [1]. The main disadvantage of this technology is that PCM leakage is not avoided. However, incorporating microencapsulated material into concrete or mortar during its mixing phase can prevent PCM leakage. A significant number of studies on the characterization of these materials [3-8] and on testing their behaviour when incorporated into building elements [9] have been published. Using these integration techniques, 5% of PCM can be retained in concrete [3-6] and nearly 25% in mortars [7-8]. As a general rule, adding PCM reduces the bulk material density, thermal conductivity and compressive strength. In most cases PCM increases the thermal inertia of the material, though the reduction in density can reduce its thermal mass. PCM can also be integrated into cement composites by impregnation into lightweight aggregates. Its absorption into different materials and its subsequent incorporation into cement composites have been analyzed in several publications. Different kinds of porous materials have been studied, including expanded shale [1,10,11], pumice [1,12], expanded clay [11,12] and expanded graphite [13,14]. By using this technique, a maximum amount of PCM of 25% can be incorporated. As in the previously described technique, the PCM normally decreases thermal conductivity and mechanical resistance. It is well-known that organic PCMs such as paraffins overcome problems such as corrosion, supercooling or segregation that hinder the use of hydrated salts in building materials [15]. Despite the benefits of these organic PCMs, several authors have reported the flammability of paraffins as one of the main drawbacks to extending the use of these PCMs to building materials [16]. The presence of organic PCMs in building materials increases the risks of fire even when incorporated in a non-flammable matrix such as gypsum or cement. To date, few works have assessed the fire performance of composite building materials with PCM. Hawes [1] used an experimental setup to make preliminary tests on different PCM concrete samples. The observed fire resistance was good and the flame spread was minimal. A moderate fume discharge was also observed in some PCM concrete samples. Salyer and Sircar [17] analysed how to retard fire in PCM-plasterboards. The authors proposed the addition of a non-flammable surface to the plasterboard, treatment with insoluble liquid fire retardant and the use of fire retardant surface coatings to prevent the wicking action of the plasterboard paper covers. Banu et al. [18] also carried out flammability tests on gypsum wallboard with approximately 24% organic PCM. Specifically, they determined the flame spread and smoke development from experiments in a Steiner tunnel, and the heat and smoke release rates using a cone calorimeter. The results showed that this PCM building material does not meet all the requirements of the National Building Code of Canada on fire characteristics for building materials. They pointed out the possibility of adding flame retardant to reduce its flammability. On the other hand, several works have analysed the flammability reduction of a form-stable phase change material based on paraffin and high density polyethylene (HDPE) when adding different types of flame retardants [19-23]. Thermogravimetric analysis and cone calorimeter tests were used. It can be concluded from the results obtained that the incorporation of flame retardants into the form-stable PCM reduces its flammability, as it was observed in the reduction of the HRR peak, having little effect on the stored thermal energy. Although in recent years many works have been presented on preparation and on thermal and mechanical properties determination of materials with cement and PCM, none of them has dealt with the fire response characterization of these materials since Hawes [1] first studied this issue in the early nineties. Nowadays, fire safety has become an important aspect for society and this is reflected in the building regulation. In this sense, fire behaviour of building materials must be tested and materials must fulfil some requirements in order to be used in certain applications. The organic nature of commonly used PCM makes necessary to include the fire performance among the parameters evaluated in studies of materials incorporating PCM. Testing methodology has to be adapted from the tests required in the standards to the laboratory scale. In this work, the fire behaviour of a mortar formulation containing granulated PCM is tested. This material has been designed for a radiant floor application, similar to that described in [24]. The addition of PCM to the radiant floor slabs increases significantly their thermal storage capacity in the temperature range in which it usually works. This effect can be used in applications where there is a high delay between thermal energy supply and demand or in case of integration energy sources with intermittent time availability such as renewable energy. In previous works [24,25] the thermal performance and economic feasibility of a radiant floor coupled to a heat pump was studied. In this case, thermal energy storage is used in order to level the energy demand, shifting electric energy consumption to night hours. The influence of PCM mass fraction in radiant floor slab on the operation of the system was analysed. It was concluded that the amount of PCM included in the radiant slab composite material has a relevant influence on the profitability of the investment [25]. Therefore, the effect of the quantity of PCM in the composite material on its reaction to fire is analysed; for this purpose, different PCM mass fractions have been tested. The fire testing methodology as well as the trends observed when paraffin based PCM are incorporated in non-combustible materials could be used and extrapolated when other combinations of paraffin PCM and building material matrix are used. 2. Materials The mortar samples were prepared using Portland cement with limestone, with denomination CEM II/B-L 32.5N, according to the standard UNE-EN 197-1:2000 [26], fine sand as aggregate, the granulated PCM GR 27 supplied by Rubitherm [27], and water. The granulated PCM (GR) is a compound in which the phase change material is bound by a clayey matrix. The compound material forms granules of a size between 1-3 mm whose phase change temperature is near 27ºC. The enthalpy-temperature curve of the granulated material has been measured. Since the sample must be representative of the material that is being investigated, the volume of the sample should be of at least a few cubic centimetres or more if possible [28]. For this reason an installation of the T-history method was chosen. This method was originally proposed by Zhang et al. [29] and later improved by Marín et al. [30] and Lázaro et al. [28]. The basic characteristics are the following: one-dimensional heat transfer in the radial direction; the system formed by the container, the reference substance and the PCM are lumped heat capacity systems; and the heat transfer from the containers of the reference substance and the PCM to the air in the chamber is by natural convection. The experiment proposed by Zhang entails recording the chamber temperature and the temperatures during the phase change of the PCM inside two equal tubes that contain respectively the substance that changes phase and the reference substance whose specific heat is known. After obtaining the temperature-time curves of the PCM and of the reference substance, these data can be used to estimate the thermophysical properties. Figure 1 shows the Enthalpy-Temperature curve of GR 27 obtained with an installation of the T-history method. The sample was ground and compacted in the sample holder for an accurate measurement. The composition of the mortar follows the prescription of the heating floor manufacturer Uponor [31]. In the reference formulation, the cement to aggregate ratio is around 1:4 and the water/cement ratio is 0.32. The PCM GR27 has been added replacing the corresponding part of the aggregate. Table 1 shows the composition of each one of the samples obtained. According to the previous results of numerical analysis [24,25], two PCM mortars with different compositions where prepared. The amount of PCM in these samples was selected within the range of optimal solutions predicted in the previous work [25]. The setting times observed for the samples with PCM were similar to that of the conventional mortar sample. The dimensions of the mortar samples are 150x100x100 mm. The samples obtained can be observed in figure 2. It can be seen that the samples with PCM show a darker tonality in the colour. This may be due to the diffusion of the liquid PCM through the mortar. 3. Experimental methodology and results 3.1 Thermal response of the mortar with PCM samples The thermal response of the mortar with PCM samples has been analysed in an experimental installation where the phenomenon of 1-D transitory conduction is reproduced. The dimension of the samples in these tests was 150x100x45 mm, taking into account the particular restrictions of the experimental installation and trying to minimize the three-dimensional effects on the heat transfer. The test methodology is as follows. The sample is placed at an initial temperature Tini, facing an air flow at a set temperature maintaining the opposite side thermally insulated. The temperature at the centre of the two faces and in the interior of the sample is measured ∞ T with a 4-wire Pt 100. Figure 3 shows the schematic arrangement of the test and figure 4 shows the measurements for the melting test with an initial temperature of the different mortar samples of 5ºC and an air flow temperature of 32ºC. The effect of the phase change material on the heat transfer process is significant, since the response time of the sample increases considerably. The response time is here defined as the time until the temperature of the insulated face reaches 90% of the temperature step to which the sample is subjected, in this case when it reaches 28ºC. In the analysis of transient heat conduction through a PCM composite material, response time cannot be used for characterizing the sample, since it depends on the boundary conditions, mainly on the difference between the air and PCM melting temperature. However it can be used to show qualitatively the effect of PCM by comparing tests of different materials with equivalent boundary conditions. For this temperature step, the response time for the PCM mortar samples with GR27 mass fractions of 10 and 25% is 9000 and 15000 seconds, respectively, compared to 5000 seconds for a mortar sample without PCM. An estimation of the thermal diffusivity of the sample can be obtained using the analytical solution for the transitory heat transfer by conduction. The analysis presented here is only applicable to materials with linear behaviour. It is thus carried out on the sample without PCM and at the beginning of the test of the PCM mortar samples before the phase change takes place. If the approximation of just one term of the solution is considered (valid for Fo>0.2), equations 1 and 2 provide the external and internal temperatures, respectively. (eq. 1) (eq. 2) where the value ξ1 is the first eigenvalue of heat transfer equation, the first positive root of the transcendental equation (equation 3). The relationship between the parameters C1 and ξ1 is defined by equation 4. t L ini eCTTTT · 111 2 2 1 )··cos()·( α ζ ζ − ∞∞ −+= t L ini eCTTTT ·· 13 2 2 1 ·)·( α ζ − ∞∞ −+= tan  (eq. 3) (eq. 4) The value of ξ1 can be obtained from the experimental results calculating the dimensionless temperatures relationship given in equation 5. (eq. 5) A least squares fitting of the evolution of the internal temperature has been accomplished, obtaining the constant C1 and the exponential decay constant (m [s-1]), that is to say, the value of the term . Table 2 shows the thermal diffusivity calculated for each sample in each one of the tests. It must be pointed out that the estimation has a significant uncertainty since the uncertainty of the parameter ξ1 is amplified because of being squared in the formula of the thermal diffusivity calculation. The uncertainty on estimation of thermal diffusivity can be calculated using equation 6 from the deviation of the experimentally determined variables m (3.5%) and ξ1 (5.3%). An uncertainty of 8.3% has been obtained.    2  (eq. 6) However, these calculated values of thermal diffusivity can be useful for the observation of the tendency of the influence of the PCM in the mortar. As expected, the addition of PCM in the mortar causes a reduction in the thermal diffusivity compared to the traditional material, since the addition of PCM has the double effect of increasing the specific heat and reducing the thermal conductivity of the bulk composite material. The thermal response of a radiant floor slab with PCM depends mainly on its latent heat thermal capacity and its thermal diffusivity. As it has been seen the addition of PCM causes a delay on the response time of radiant floor due to the phase change process and the reduction of thermal diffusivity. This effect can be attractive for thermal energy storage in the radiant floor slab. )ζ·sin(ζ·)ζ·sin( C11 1 122 4 + = 3 1 1)cos( TT TT − − = ∞ ∞ ζ 2 2 1· L α ζ 3.2 Fire reaction The characterization of the properties of materials subjected to high temperatures is complex and it is necessary to evaluate several parameters in order to study their behaviour. Some of the most important occurrences that could increase the hazards in case of fire are the presence of sustained flames, the production of burning drops during combustion or the release of dense smoke that hinders visibility. The addition of an organic flammable material such as paraffin PCM makes necessary to classify the fire reaction of the mortar prior to its use in real buildings. In this case, dripping tests, smoke release tests, small-scale fire resistance tests and analysis with a pyrolysis combustion flow calorimeter have been performed to assess the fire behaviour of mortars containing PCM. 3.2.1 Dripping test A radiator device described in the Spanish UNE 23725-90 standard [32] was employed to measure the melting behaviour of the material and the degree of extinguishability once combustion occurs. The device is shown in figure 5. Samples of 100x100x10 mm were placed on a metallic grid 3 cm below a heat source of 500 W, which was taken away and put back after each ignition and extinction. Three samples of each composition were tested and the parameters determined were the time to ignition, the number of ignitions and the average time of flame persistence during the first 5 minutes of combustion. The results of the dripping test are summarized in table 3. As expected, the mortar without PCM was not flammable and did not undergo any change during the test. The samples containing 10 and 25% PCM showed a similar time to ignition (TTI) of approximately 38 s. The TTI indicates the moment when the first ignition occurs after the heat source is applied to the samples. Despite the coincidence in the TTI, the samples with 10% PCM showed shorter average flame persistence and a higher number of ignitions. Short combustion times and a high number of ignitions are characteristic of a material that easily auto-extinguishes the flame when the heat source is removed. It should be noted that one of the parameters that negatively affects the fire reaction classification of the material is the occurrence of dripping during the test. In this case, none of the studied samples produced drops. The mortar with 10% PCM exhibited low flame [22] P. Zhang, Y. Hu, L. Song, J. Ni, W. Xing, J. Wang, Effect of expanded graphite on properties of high-density polyethylene / paraffin composite with intumescent flame retardant as a shape-stabilized phase change material, Solar Energy Materials and Solar Cells 94 (2010) 360-365. [23] P. Sittisart, M.M. Farid, Fire retardants for phase change materials, Applied Energy 88 Spanish Association for Standardization and Certification (AENOR), 1990. [24] J. Mazo, M. Delgado, J.M. Marin, B. Zalba, Modeling a radiant floor system with Phase Change Material (PCM) integrated into a building simulation tool: Analysis of a case study of a floor heating system coupled to a heat pump, Energy and Buildings 47 (2012) 458-466. [25] J. Mazo, M. Delgado, J.M. Marin, B. Zalba, Analysis of a floor heating system with PCM coupled to a heat pump. Study of its technical and economic feasibility, in: Innostock 2012 The 12th International Conference on Energy Storage, Lleida, Spain, 2012. [26] UNE-EN 197-1:2000, Cement-Part 1: Composition, specifications and conformity criteria for common cements. Spanish Association for Standardization and Certification (AENOR), 2000. [27] Rubitherm, http://www.rubitherm.de/english/index.htm (access date: May 2014) [28] A. Lázaro, E. Günther, H. Mehling, S. Hiebler, M.J. Martin, B. Zalba, Verification of T-history installation to measure enthalpy versus temperature curves of phase change materials, Measurement Science and Technology 17 (8) (2006) 2168–2174.. [29] Y. Zhang, Y. Jiang, Y. Jiang, A simple method, the T-history method, of determining the heat of fusion, specific heat and thermal conductivity of phase-change materials, Measurement Science and Tecnology 10 (3) (1999) 201-205. [30] J.M. Marin, B. Zalba, L.F. Cabeza, H. Mehling, Determination of enthalpy temperature curves of phase change materials with the temperature-history method: improvement to temperature dependent properties, Measurement Science and Technology 14 (2) (2003) 184–189. [31] Uponor, http://www.uponor.es/ (access date: May 2014) [32] UNE 23725:1990, Reaction to fire tests of building materials. Dripping test with electrical radiator used for melting materials (complementary test), Spanish Association for Standardization and Certification (AENOR), 1990. [33] ASTM D7309–13, Standard test method for determining flammability characteristics of plastics and other solid materials using microscale combustion calorimetry, ASTM International, 2013. [34] L. Bayés-García, L. Ventolà, R. Cordobilla, R. Benages, T. Calvet, M.A. Cuevas-Diarte, Phase Change Materials (PCM) microcapsules with different shell compositions: Preparation, characterization and thermal stability, Solar Energy Materials and Solar Cells, 94, (7) (2010) 1235–1240. [35] Charles Q. Yang, Qingliang He, Richard E. Lyon, Yuan Hu, Investigation of the flammability of different textile fabrics using micro-scale combustion calorimetry, Polymer Degradation and Stability 95 (2010) 108-115 [36] Yaru Shi, Takashi Kashiwagi, Richard N. Walters, Jeffrey W. Gilman, Richard E. Lyon, Dotsevi Y. Sogah, Ethylene vinyl acetate/layered silicate nanocomposites prepared by a surfactant-free method: Enhanced flame retardant and mechanical properties, Polymer 50, (15) (2009) 3478–3487 [37] R. E. Lyon, R.N. Walters, S.I. Stoliarov, Screening Flame Retardants for Plastics Using Microscale Combustion Calorimetry, Polymer Engineering and Science, (2007) 1501-1510 [38] UNE-EN 1363-1:2000, Fire resistance tests. Part 1: General requirements. Spanish Association for Standardization and Certification (AENOR), 2000. Figure captions Figure 1. Enthalpy-temperature curves for the melting and solidification of GR 27 obtained with a T-history installation. Figure 2. Comparative image of the obtained samples. From left to right: Mortar without PCM, with 10% PCM and with 25% PCM. Figure 3. Diagram of the thermal response test Figure 4. Comparison of tests for the three PCM mortar samples Figure 5. Radiator device used in the dripping test Figure 6. Transmitted light percentage of the different mortar samples measured in the smoke test. Figure 7. Heat released rate vs. temperature for the different samples. Figure 8. Oven used for the small-scale fire resistance tests Figure 9. Temperatures of the exposed and unexposed surfaces in the small scale resistance test Figure 10. Detail of the temperatures of the exposed surfaces in the small scale resistance test Figure 11. Detail of the temperatures of the unexposed surfaces in the small scale resistance test Highlights  Thermal behaviour and fire reaction of cement mortars with GR27 have been analyzed  The GR27 enthalpy-temperature curves have been obtained with a T-history installation  An estimation of the thermal diffusivity of these PCM mortars has been accomplished  The PCM mortars have shown low capacity to spread the flame in case of fire  10% GR27 mortar could be used in radiant floor systems with convenient protection *Highlights (for review) Figure captions Figure 1. Enthalpy-temperature curves for the melting and solidification of GR 27 obtained with a T-history installation. Figure 2. Comparative image of the obtained samples. From left to right: Mortar without PCM, with 10% PCM and with 25% PCM. Figure 3. Diagram of the thermal response test Figure 4. Comparison of tests for the three PCM mortar samples Figure 5. Radiator device used in the dripping test Figure 6. Transmitted light percentage of the different mortar samples measured in the smoke test. Figure 7. Heat released rate vs. temperature for the different samples. Figure 8. Oven used for the small-scale fire resistance tests Figure 9. Temperatures of the exposed and unexposed surfaces in the small scale resistance test Figure 10. Detail of the temperatures of the exposed surfaces in the small scale resistance test Figure 11. Detail of the temperatures of the unexposed surfaces in the small scale resistance test List of Figure Captions Sample Cement (g) Aggregate (g) GR 27 (g) 0% PCM 343 1393 0 10% PCM 283 972 144 25% PCM 310 809 378 Table 1. Mortar samples composition. Table(s) with Caption(s) Sample Test number Estimation of thermal diffusivity (mm2 /s) 1 0.79 2 0.82 1 0.61 2 0.57 1 0.54 2 0.48 0% PCM 10% PCM 25% PCM Table 2. Estimation of thermal diffusivity of the samples Table(s) with Caption(s) TTI (s) Number of ignitions Average combustion extent (s) 0% PCM - - - 10% PCM 38.5 35 5 25% PCM 38 17 13 Table 3. Dripping test results. Table(s) with Caption(s) PHRR (W/g) TPHRR (ºC) HRC (J/gºC) THR (kJ/g) GR27 186 208 376 14.43 0% PCM - - - - 10% PCM 15 178 17 0.77 25% PCM 50 206 94 4.29 Table 4. Flammability parameters from the PCFC test. Table(s) with Caption(s) Figure(s) Click here to download high resolution image Figure(s) Click here to download high resolution image Figure(s) Click here to download high resolution image Figure(s) Click here to download high resolution image Figure(s) Click here to download high resolution image Figure(s) Click here to download high resolution image Figure(s) Click here to download high resolution image Figure(s) Click here to download high resolution image Figure(s) Click here to download high resolution image Figure(s) Click here to download high resolution image Figure(s) Click here to download high resolution image