1 Use of sewage sludge combustion ash and gasification ash for high-temperature desulphurization of different gas streams N. Gil-Lalaguna *, J. L. Sánchez, M. B. Murillo, G. Gea Thermo-chemical Processes Group, Aragón Institute of Engineering Research (I3A), Universidad de Zaragoza, c/ Mariano Esquillor s/n., 50018, Zaragoza, Spain. * Corresponding Author Tel: +34976762224 e-mail:
[email protected] Abstract Due to its metal content, sewage sludge ash appears as a potential sorbent material for H2S removal at high temperature. The desulphurization ability of the solid by-products of combustion and gasification of sewage sludge has been evaluated in this work. Ash characterization results revealed that metal fraction in sewage sludge did not remained completely inert during the combustion and gasification processes. Iron content was lower in the gasification ash and X-ray patterns showed different crystalline phases in the solids: Fe2O3 in the combustion ash and Fe3O4 in the gasification ash. These differences resulted in a lower sulphur capture capacity of the gasification ash. Desulphurization tests were carried out in a lab-scale fixed bed reactor operating at 600- 800 ºC. Different gases containing 5000 ppmv H2S (H2S/N2 mixture and synthetic gasification gas) were used. The H2S breakthrough curves were negatively affected by the reducing atmosphere created by the gasification gas and by the presence of steam in the reaction medium. However, H2S breakthrough curves alone do not provide enough information to evaluate the sulphur capture capacity of the sorbent materials. Ultimate analyses of the spent solid samples showed that the total amount of H2S removed from the gas was only partially captured in the ash. Thermodynamic data pointed to a significant fraction of sulphur forming part of other gases, such as SO2. In the best
2 operating conditions, an outlet gas with less than 100 ppmv of H2S was obtained during 300 min, thus resulting in a sulphur loading of 63 mg S·g-1ash. This experimental sulphur content was 39% lower than the maximum theoretical value predicted by equilibrium simulations. Keywords: H2S removal; hot gas cleaning; sewage sludge; combustion ash; gasification ash. 1. Introduction Sewage sludge has become an increasingly important residue needing effective management. Due to the organic nature of sewage sludge, thermal processes such as pyrolysis, gasification or combustion have attracted considerable scientific interest as a potential route to its energy valorization [1-3]. However, as occurs in most thermochemical treatments of wastes and solid fuels, various impurities are found in the products of interest deriving from these processes, which significantly limits their final uses. One of these impurities is H2S, present in the gaseous products of both the pyrolysis and the gasification of sewage sludge due to its initial content of sulphur compounds [4]. As is well known, H2S emissions to the atmosphere (or SO2 emissions in the case of burning a H2S-containing gas) entail environmental problems related to acid rain. In addition, the presence of H2S in the gas leads to operational problems such as corrosion in pipes, engines or turbines, as well as the deactivation of the common catalysts used for tar cracking and gas reforming after gasification processes [5]. Several low and high temperature processes for the elimination of H2S from products or off-gases have been described and developed at various stages. Wet scrubbing with selected solvents has been a widely used low-temperature process in the chemical process industry [6]. The use of activated carbons for H2S removal at low
3 temperature has also been extensively studied [7-9]. Given the combination of their unique surface features (high specific surface and pore volume) and surface chemistry (improved by the addition of functional groups or by its metallic content), activated carbon-based materials have been proved to work efficiently as adsorbents of sulphurcontaining species such as H2S, SO2 or methyl mercaptans from the gas phase. As a result of surface reactions, H2S can be oxidized to either sulphur or SO2 [8]. Activated carbons of different characteristics have also been prepared from sewage sludge pyrolysis or carbonization [10-13], obtaining pollutant removal results comparable to those corresponding to commercial catalytic activated carbons [13]. On the other hand, high temperature desulphurization processes are advantageous from an energy standpoint as a result of the elimination of gas cooling and the associated heat exchangers [14]. Different studies on the use of metal oxide based sorbents for hot gas desulphurization can be found in the literature [14-20]. Zinc, manganese, copper, iron, rare earth, and calcium sorbents are among the most promising and most extensively studied [14, 15]. Typically, metal oxides are converted to sulphides during a sulphur loading stage under reducing hot gas conditions. After sulphidation, the spent metal sulphides can be regenerated back to metal oxides by using oxygen, steam, SO2 or a combination of these [14]. Ash residues derived from thermo-chemical processes are known to contain metal oxides in different proportions, so its use as sorbent materials for H2S removal from hot gases could be an attractive alternative due to its low cost. This is the case of sewage sludge ash, in which this work focuses. An integrated process could be proposed to remove the H2S produced during thermo-chemical treatment of sewage sludge by using the own ash resulting from these processes in a downstream cleaning stage. The desulphurization capacity of the solid by-products derived from the combustion and
4 gasification of sewage sludge has been evaluated in this work. Desulphurization tests were carried out in a lab-scale fixed bed reactor and the effects of temperature, type of sewage sludge ash, presence of steam and type of H2S-containing gas were studied, thus extending an earlier work performed by our group [20]. 2. Materials and methods 2.1. Sewage sludge ash The raw material used to obtain the ash samples was anaerobically digested and thermally dried sewage sludge. Sewage sludge combustion was performed under air atmosphere in a heating muffle furnace at 900 ºC (heating rate of 20 ºC·min-1) during two hours. The sewage sludge gasification ash was obtained in a previous gasification study performed in a lab-scale fluidized bed reactor at 850 ºC, using a mixture of steam and air as gasifying agent (H2O/O2 molar ratio = 1) [4]. The fresh ash samples were characterized by various techniques. Ultimate analyses were performed using a Leco TruSpec Micro elemental analyzer. The textural properties such as the BET surface area and the average pore size and volume (BJH method) were calculated from N2 physisorption isotherms (BET volumetric method) using a Micromeritics TriStar II 3000 analyzer. The N2 adsorption-desorption isotherms were obtained at -196 ºC and room temperature, respectively, over the whole range of relative pressures. The samples were previously degasified at 200 ºC during 8 h in a N2 flow. Powder X-ray diffraction (XRD) patterns of the fresh samples were acquired with a D- Max Rigaku diffractometer equipped with a copper anode (voltage of 40 kV and current of 80 mA). The measurements were completed in the Bragg’s angle (2θ) range from 5º to 95º, using a scanning rate of 0.03º·s-1. Phases present in the solid samples were defined according to the JCPDS-International Centre for Diffraction Data 2000
5 database. Lastly, metal content in the ash samples was analyzed by inductively coupled plasma combined with optical emission spectroscopy (ICP-OES), using a Thermo Elemental IRIS Intrepid ICP-OES spectrometer. The samples were dissolved by microwave-assisted acid digestion in a CEM MARS microwave reaction system. 2.2. Experimental setup and operating conditions The desulphurization tests were performed at atmospheric pressure in a fixed-bed quartz tubular reactor of 1.2 cm internal diameter and 40 cm length. A schematic diagram of the installation used for the desulphurization tests is shown in Fig. 1. The reactor was packed with 1 g of the solid material (combustion ash or gasification ash), which was supported on a fiberglass fleece located 18.5 cm from the top of the reactor. A K-type thermocouple was located in the middle of the solid bed and the reactor was electrically heated to the final temperature (600, 700 or 800 ºC). The flow rate of the H2S-containing gas was adjusted to 50 mLSTP·min-1 (STP: standard conditions of temperature and pressure at 0 ºC and 1 atm) by means of a previously calibrated mass flow controller. Two different inlet gases containing 5000 ppmv H2S were used to evaluate the effect of the gas components on the desulphurization process: (i) a gas mixture only containing H2S and N2 and (ii) a synthetic gasification gas, similar to the dry product gas of sewage sludge gasification [4]. Table 1 shows the composition of both gas mixtures. On the one hand, the H2S/N2 mixture allows the assessment of the desulphurization process without involving any interference from other gases. On the other hand, the synthetic gasification gas simulates more real conditions for the H2S removal from a gasification gas. Steam was also added in some tests in order to evaluate its effect on the desulphurization ability of the solids. The required flow of liquid water (0-1 g·h-1) was accurately adjusted by a HPLC pump and was evaporated before entering the reactor. Steam concentration in the gas entering the reactor varied from 0 to
6 30 vol. %, which led to a H2O/H2S mass ratio varying from 0 to 45 g H2O/g H2S. The weight hourly space velocity during the experiments ranged between 3.7 h-1 and 4.7 h-1 depending on the steam feed rate. The gas-solid contact time was chosen after preliminary experiments and based on earlier studies [20]. The reactor containing the ash sample was flushed with a N2 flow while heating. The experiment started when the desired temperature was reached in the solid bed. Just then the N2 flow was replaced by the synthetic gasification gas or by the H2S/N2 mixture. The composition of the outlet gas was continuously analyzed during the experiments by means of an Agilent Micro-GC 3000 (sample injection every four minutes). The H2S outlet flow (mLSTP·min-1) was calculated from the gas composition data taking the nitrogen of the gas mixture as an internal standard. The evolution of the H2S outlet flow with time is depicted in the H2S breakthrough curves. Initially, the established time for the experiments was two hours, but reaction time was extended in some cases to 240 or 390 min (Table 2) in order to reach the H2S breakthrough time. After the desulphurization tests, sulphur content in the ash samples was determined with a Leco TruSpec Micro elemental analyzer. Furthermore, one of the ash samples was morphologically and chemically characterized by scanning electron microscopy combined with energy dispersive X-ray spectroscopy (SEM/EDX) and by X-ray photoelectron spectroscopy (XPS). A FEI Inspect F50 microscope was used for the SEM/EDX analysis. External metal coating was not applied to the solid sample. The back-scattered electron imaging mode was used in the EDX analysis (acquisition time of 1 min). The XPS measurements were performed with a Kratos AXIS ultra DLD spectrometer by using monochromatic Al Kα (1486.6 eV) X-ray source and a chamber pressure of around 3·10-8 Pa. The quantification of the XPS spectra was carried out with
7 the help of the CasaXPS software and the spectra were deconvoluted by applying Gaussian-Lorentzian line-shapes with Shirley-type background. Table 2 summarizes the operating conditions for the desulphurization tests. In summary, the operating factors studied were the following: bed temperature (600-800 ºC), H2O/H2S mass ratio in the inlet gas (0-45 g/g), type of sewage sludge ash (combustion ash or gasification ash) and type of H2S-containing gas (H2S/N2 mixture or synthetic gasification gas). Blank tests (with no bed material) were also performed at the different temperatures and gas atmospheres in order to assess any side effect of the experimental setup caused, for example, by the reaction of H2S with the hot metal parts (made of steel) at the reactor inlet and outlet. On the other hand, experimental variability was evaluated through three replicates performed when feeding the H2S/N2 mixture and operating in the intermediate values of temperature (700 ºC) and H2O/H2S mass ratio (22.5 g/g). The impact of the studied factors was statistically analyzed by means of analysis of variance ANOVA (confidence level of 95% for the F-distribution). Design-Expert® 7 software (from Stat-Ease, Inc.) was used for this purpose. The use of coded levels for the factors (-1 for the lower limits and +1 for the upper limits) in the ANOVA analysis enables an easy identification of the term with the greatest influence: the higher the absolute value of the coefficient, the more influential the factor. Although the type of sewage sludge ash is not a numerical factor, a coded value of -1 was assigned to the combustion ash and +1 to the gasification ash in order to obtain comparable coefficients from the ANOVA analysis. The desulphurization tests performed at the laboratory were also theoretically simulated to determine the maximum amount of H2S that could be removed from the gas from a thermodynamic point of view. HSC Chemistry® 6.1 software was used for this purpose. This software uses the Gibbs energy minimization method to calculate the
8 amounts of products at equilibrium in isothermal and isobaric conditions. The reaction system must be specified for the calculations. 3. Results and discussion The characterization results of the fresh ash samples are presented in subsection 3.1. After that, desulphurization performance results are shown and discussed in two different subsections according to the gas mixture used (3.2 and 3.3). The H2S breakthrough curves and the sulphur content in the solid samples (expected and measured data) are the main results evaluated. 3.1. Characterization of the fresh ash samples Table 3 summarizes the characterization results of the fresh ash samples resulting from combustion and gasification of sewage sludge. Both solids contained a small fraction of sulphur and some amount of carbon was also present in the gasification ash (around 3 wt. %). The surface properties of sewage sludge ash are not good enough for its use as an adsorbent material, but its desulphurization potential is based on its metallic content. The main metallic elements detected by ICP-OES were Fe, Si, Ca and Al. According to the thermodynamic study reported by Westmoreland and Harrison [21] concerning the desulphurization potential of different metal oxides, Ca and Fe oxides are able to react with H2S to form metal sulphides, so both ash samples are potential sulphur sorbents. Some differences were found in the metal content of the solids, which might indicate that the ash fraction of sewage sludge did not remained completely inert during the combustion and gasification processes. Heterogeneity of sewage sludge may also explain these differences. Particularly striking is the case of Fe content which was much lower in the gasification ash. Part of the Fe content in the raw sewage sludge could be in the form of iron chloride (FeCl3) as a result of the use of this compound as a
9 coagulant agent in the wastewater treatment plant. During combustion, the excess oxygen appears to favor the retention of Fe in the ash in the oxide form. However, part of the Fe content could remain as FeCl3 during the gasification process due to the reduced presence of oxygen, so this amount of Fe could leave the reactor in the gas phase due to the low boiling point of FeCl3 (315 ºC) [22]. Fig. 2 shows the XRD patterns of the combustion ash and gasification ash before the desulphurization tests. Species such as quartz, calcite, iron oxides and different calcium and iron phosphates were detected in the ash samples. The oxidation state of Fe is one of the main differences in the XRD patterns: Fe appears in the form of hematite (Fe2O3) in the combustion ash and in the form of magnetite (Fe3O4) in the gasification ash. Concordantly, the reddish color characteristic of hematite was only observed on the combustion ash. 3.2. Desulphurization performance: H2S/N2 mixture as inlet gas Different tolerable levels of sulphur in gas products can be found in the literature depending on the gas application. For instance, the H2S concentration limit ranges between 20 and 750 ppmv for gas turbine applications [14]. An intermediate value of 100 ppmv has been used in this work to define the H2S breakthrough time. The H2S breakthrough curves obtained for the dry and moist H2S/N2 mixtures are depicted in Fig. 3 as a function of temperature and type of ash. A gas essentially free of H2S was obtained during 300 min and 260 min when using the combustion ash and the gasification ash, respectively, at 800 ºC and under dry conditions (Fig. 3a). However, when steam was present in the reaction medium, the H2S breakthrough time corresponding to the combustion ash was reduced to 50 min, while an abrupt increase in the H2S outlet flow was observed from the beginning of the experiment when using the gasification ash (Fig. 3b). According to the general reaction of metal oxides with H2S
16 of ash. The H2S concentration in the outlet gasification gas remained below 100 ppmv for less time than in the previous case (H2S/N2 mixture). Unlike occurring with the H2S/N2 mixture, a significant H2S flow was detected in the outlet synthetic gasification gas from almost the beginning of all the experiments (Fig. 7). In this case, the H2S breakthrough time was longer than 20 min only by operating with the combustion ash at 600 ºC and dry conditions (165 min). This breakthrough time was in turn significantly lower than that obtained for the H2S/N2 mixture under the same operating conditions (260 min). Reduction of iron oxides present in sewage sludge ash may explain this observed behavior. As discussed in the literature [17,21,25], the presence of CO and H2 in the gasification gas creates a reducing atmosphere that causes the conversion of Fe3O4 and Fe2O3 to FeO or even to Fe0 in the temperature range of 700-1000 ºC. FeO and Fe0 show less favorable sulphidation equilibrium, which led to a reduction in the sulphur capture capacity [25].. The temperature rise from 600 to 800 ºC was found to be detrimental for the H2S removal capacity of the combustion ash, probably as a consequence of the higher reduction rate of Fe2O3 to FeO at 800 ºC (Fig. 7a). However, the H2S removal capacity of the gasification ash improved at higher temperature. Thus, the impact of temperature on the H2S removal from the gasification gas is the result of the competition of reduction and sulphidation reaction rates. The influence of the other factors (presence of steam and type of sludge ash) on the H2S removal from the gasification gas was similar to the previous case. Table 4 shows the results of the sulphur content measured in the samples after the experiments performed with the synthetic gasification gas, as well as data calculated according to the sulphur mass balance (3). Even though the longest H2S breakthrough time was obtained for the combustion ash at 600 ºC, the highest sulphur loading was detected in the ash used at 800 ºC (46 vs. 55 mg S·g-1ash after 240 min). The different
17 shape of the H2S breakthrough curves explains this result. After the desulphurization of the moist gasification gas, the highest sulphur content was found in the combustion ash operating at 600 ºC (26.8 mg S·g-1ash after 120 min). This value was slightly higher than that obtained after the desulphurization of the moist H2S/N2 mixture. Therefore, although the gasification gas reduced the H2S breakthrough time, sulphur loading in the solid was not negatively affected. Thermodynamic data obtained for the synthetic gasification gas feed are shown in Fig. 8. In this case, neither SO2 nor CaSO4 are present at equilibrium conditions since the reducing atmosphere created by the gasification gas prevents its formation. H2S, CaS and FexSy are the main sulphur-containing species. Some authors have experimentally detected the formation of COS in the reducing environment of the gasification gas (H2S + CO2 ↔ COS + H2O) [26], which could explain the observed differences in the expected and measured sulphur contents in the ash samples.The comparison of Figs. 4 and 8 shows a great impact of the gas atmosphere on the distribution of sulphur between CaS and FexSy. The presence of CO2 in the gasification gas can explain this difference since this is the responsible gas for the carbonation reaction of CaO (CaO + CO2 ↔ CaCO3). Excess CO2 shifts the reaction to the formation of CaCO3, especially at low temperatures, thus limiting the formation of CaS from CaO. Maximum sulphur loadings of 85, 84, 42 and 41 mg S·g-1ash were predicted for experiments 20, 21, 22 and 23, respectively. Experimental results were 46%, 35%, 36% and 79% lower than the theoretical results, respectively (Table 4). Besides the H2S removal, the composition of the inlet gasification gas was modified during the desulphurization process under certain operating conditions, thus some catalytic activity could be attributed to sewage sludge ash. The evolution of the outlet concentrations of H2, CO, CO2 and C2Hx when feeding the moist synthetic gasification
18 gas is depicted in Fig. 9. As can be noted, the use of both types of sewage sludge ash at 800 ºC led to a slight increase in the fractions of H2 and CO2 and a decrease in the percentage of CO with respect to the inlet gasification gas composition. This could be attributed to an enhancement of the water-gas shift reaction (CO + H2O ↔ CO2 + H2). Fe content in sewage sludge ash may explain this catalytic activity [27]. Furthermore, the fraction of C2Hx was slightly reduced, suggesting an enhancement of steam reforming reactions. The fraction of CH4 (not shown in Fig. 9) was not modified in any case (4.0 vol. %). As shown in Fig. 9, the composition of the synthetic gasification gas was hardly modified during the blank runs and during the experiments performed at 600 ºC. 4. Conclusions The use of the solid by-products of combustion and gasification of sewage sludge for high-temperature desulphurization (600-800 ºC) of different gases containing 5000 ppmv H2S has been evaluated in this work. The best results were obtained by using the combustion ash for H2S removal from a dry mixture of H2S/N2 at 800 ºC. The H2S breakthrough time (< 100 ppmv H2S) was around 300 min and the sulphur loading in the spent ash was 63 mg S·g-1ash. The presence of 30% steam drastically reduced the H2S breakthrough time by 85%. Thus, the use of sewage sludge ash for H2S removal at 600-800 ºC is only suitable for dry gases cleaning. In general, the gasification ash showed worse desulphurization ability than the combustion ash. Iron content was lower in the gasification ash (116 mg Fe·g-1ash) than in the combustion ash (192 mg Fe·g-1ash) and different crystalline species were detected in the ash samples: Fe2O3 in the combustion ash and Fe3O4 in the gasification ash. The reducing atmosphere created by the gasification gas negatively affected the H2S removal due to the simultaneous reduction of Fe2O3 and Fe3O4 to FeO, whose sulphur capture capacity has been proved
19 to be lower. H2S was the only sulphur-containing gas analyzed during the experiments. However, thermodynamic data pointed to the possible formation of other sulphurcontaining gases during the desulphurization process, such as SO2 or COS (this latter in a very low proportion). Therefore, the analysis of the H2S breakthrough curves alone can lead to misleading conclusions about the sulphur capture capacity of a sorbent material. In most cases, sulphur loading detected by the elemental analyzer in the spent combustion ash was 35-50% lower than the maximum thermodynamic data calculated assuming that the total content of calcium and iron in the solid was in the form of CaO and Fe2O3, respectively. Acknowledgements The authors gratefully acknowledge the financial support provided by the Spanish Ministry of Science and Technology (research project CTQ2010-20137) and the Spanish Ministry of Education (pre-doctoral grant awarded to N. Gil-Lalaguna, AP2009-3446). Authors would also like to acknowledge the use of Servicio General de Apoyo a la Investigación (SAI, Universidad de Zaragoza) and the use of the X-ray photoelectron spectrometer and the scanning electron microscope available in the Laboratorio de Microscopías Avanzadas (LMA) at Instituto de Nanociencia de Aragón (Universidad de Zaragoza). References [1] Rulkens W. Sewage sludge as a biomass resource for the production of energy: Overview and assessment of the various options. Energy Fuel. 2008; 22:9-15. [2] Fytili D, Zabaniotou A. Utilization of sewage sludge in EU application of old and new methods - A review. Renew. Sust. Energ. Rev. 2008; 12:116-40.
20 [3] Manara P, Zabaniotou A. Towards sewage sludge based biofuels via thermochemical conversion - A review. Renew. Sust. Energ. Rev. 2012; 16:2566-82. [4] Gil-Lalaguna N, Sánchez JL, Murillo MB, Rodríguez E, Gea G. Air-steam gasification of sewage sludge in a fluidized bed. Influence of some operating conditions. Chem. Eng. J. 2014; 248:373-82. [5] Abu El-Rub Z, Bramer EA, Brem G. Review of catalysts for tar elimination in biomass gasification processes. Ind. Eng. Chem. Res. 2004; 43:6911-9. [6] Yildirim O, Kiss AA, Hüser N, Leßmann K, Kenig EY. Reactive absorption in chemical process industry: a review on current activities. Chem. Eng. J. 2012; 213:371-91. [7] Bagreev A, Bandosz TJ. On the mechanism of hydrogen sulfide removal from moist air on catalytic carbonaceous adsorbents. Ind. Eng. Chem. Res. 2005; 44:530-8. [8] Bandosz TJ. On the adsorption/oxidation of hydrogen sulfide on activated carbons at ambient temperatures. J. Colloid. Interf. Sci. 2002; 246:1-20. [9] Primavera A, Trovarelli A, Andreussi P, Dolcetti G. The effect of water in the lowtemperature catalytic oxidation of hydrogen sulfide to sulfur over activated carbon. Appl. Catal. A-Gen. 1998; 173:185-92. [10] Gutiérrez-Ortiz FJ, Aguilera PG, Ollero P. Biogas desulfurization by adsorption on thermally treated sewage-sludge. Sep. Purif. Technol. 2014; 123:200-13. [11] Ros A, Montes-Morán M, Fuente E, Nevskaia DM, Martin MJ. Dried sludges and sludge-based chars for H2S removal at low temperature: influence of sewage sludge characteristics. Environ. Sci. Technol. 2006; 40:302-9. [12] Ansari A, Bagreev A, Bandosz TJ. Effect of adsorbent composition on H2S removal on sewage sludge-based materials enriched with carbonaceous phase. Carbon 2005; 43:1039-48.
21 [13] Yuan W, Bandosz TJ. Removal of hydrogen sulfide from biogas on sludge-derived adsorbents. Fuel 2007; 86:2736-46. [14] Meng X, Jong W, Pal R, Verkooijen AHM. In bed and downstream hot gas desulphurization during solid fuel gasification: a review. Fuel Process. Technol. 2010; 91:964-81. [15] Cheah S, Carpenter DL, Magrini-Bair KA. Review of mid- to hightemperature sulfur sorbents for desulphurization of biomass- and coal-derived syngas. Energy Fuel 2009; 23:5291-307. [16] Park NK, Lee DH, Lee JD, Chang WC, Ryu SO, Lee TJ. Effects of reduction of metal oxide sorbents on reactivity and physical properties during hot gas desulphurization in IGCC. Fuel 2005; 84:2158-64. [17] Tamhankar SS, Hasatani M, Wen CY. Kinetic studies on the reactions involved in the hot gas desulfurization using a regenerable iron oxide sorbent - I: Reduction and sulfidation of iron oxide. Chem. Eng. Sci. 1981; 36:1181-91. [18] Álvarez-Rodríguez R, Clemente-Jul C. Hot gas desulphurisation with dolomite sorbent in coal gasification. Fuel 2008; 87:3513-21. [19] Elseviers WF, Verelst H. Transition metal oxides for hot gas desulphurization. Fuel 1999; 78:601-12. [20] García G, Cascarosa E, Ábrego J, Gonzalo A, Sánchez JL. Use of different residues for high temperature desulphurisation of gasification gas. Chem. Eng. J. 2011; 174:644-51. [21] Westmoreland PR, Harrison DP. Evaluation of candidate solids for hightemperature desulfurization of low-btu gases. Environ. Sci. Technol. 1976; 10:659- 61.
22 [22] Perry RH, Green DW. Perry’s Chemical Engineer’s Handbook. 7th ed. New York: McGraw-Hill; 1999. [23] Kim K, Jeon SK, Vo C, Park CS, Norbeck JM. Removal of H2S from steamhydrogasifier product gas by zinc oxide sorbent. Ind. Eng. Chem. Res. 2007; 46:5848-54. [24] Yoshimura Y, Yasuda H, Sato T, Shimada H. Utilization of thermodynamic database in the systems using molybdate and iron based catalysis. Coal Sci. Technol. 1995; 24:1275-8. [25] Tseng TK, Chang HC, Chu H, Chen HT. Hydrogen sulfide removal from coal gas by the metal-ferrite sorbents made from the heavy metal wastewater sludge. J. Hazard. Mater. 2008; 160:482-8. [26] Hepola J, Simell P. Sulphur poisoning of nickel-based hot gas cleaning catalysts in synthetic gasification gas. I. Effect of different process parameters. Appl. Catal. B- Environ. 1997; 14:287-303. [27] Liu QS, Zhang QC, Ma WP, He RX, Kou LJ, Mou ZJ. Progress in water-gas-shift catalyst. Prog. Chem. 2005; 17:389-98.
23 Table 1. Composition of the gas mixtures (dry basis). Gas component H2S/N2 mixture (vol. %) Synthetic gasification gas (vol. %) CO -- 10.0 CO2 -- 15.0 H2 -- 10.0 CH4 -- 4.0 C2H6 -- 0.2 C2H4 -- 1.5 C2H2 -- 0.2 H2S 0.5 0.5 N2 99.5 58.6
24 Table 2. Operating conditions in the desulphurization tests. Experiment Origin of sewage sludge ash Synthetic gas mixture Temperature (ºC) H2O/H2S mass ratio Test duration (min) 1 Combustion H2S/N2600 0 300 2 Combustion H2S/N2800 0 390 3 Combustion H2S/N2600 45 120 4 Combustion H2S/N2800 45 120 5,6,7 Combustion H2S/N2700 22.5 120 8 Gasification H2S/N2600 0 120 9 Gasification H2S/N2800 0 390 10 Gasification H2S/N2600 45 120 11 Gasification H2S/N2800 45 120 12,13,14 Gasification H2S/N2700 22.5 120 15 Blank run H2S/N2600 0 120 16 Blank run H2S/N2800 0 120 17 Blank run H2S/N2600 45 120 18 Blank run H2S/N2800 45 120 19 Blank run H2S/N2700 22.5 120 20 Combustion Gasification g as 600 0 240 21 Combustion Gasification g as 800 0 240 22 Combustion Gasification gas 600 45 120 23 Combustion Gasification g as 800 45 120 24 Gasification Gasification g as 600 0 120 25 Gasification Gasification g as 800 0 240 26 Gasification Gasification g as 600 45 120 27 Gasification Gasification g as 800 45 120 28 Blank run Gasification g as 600 0 120 29 Blank run Gasification g as 800 0 240 30 Blank run Gasification g as 600 45 120 31 Blank run Gasification g as 800 45 120
25 Table 3. Characterization of the ash derived from sewage sludge combustion and sewage sludge gasification. Sewage sludge combustion ash Sewage sludge gasification ash Ultimate analysis C (wt. %) 0.15 3.14 H (wt. %) n.d.a n.d.a N (wt. %) 0.28 0.77 S (wt. %) 0.46 0.41 BET surface (m2·g-1) 6.5 6.7 Pore volume (cm3·g-1) 0.02 0.02 Average pore size (nm) 12.0 10.9 Metal content (mg·g-1ash) Al 52 61 Ca 65 84 Fe 192 116 K 14 n.a. b P 63 51 Mg 17 n.a. b Na 4 n.a. b Si 122 n.a. b Ti 4 n.a. b a not detected; b not analyzed
32 (a) Dry H2S/N2 mixture; 600 ºC (b) Dry H2S/N2 mixture; 800 ºC (c) Moist H2S/N2 mixture; 600 ºC (d) Moist H2S/N2 mixture; 800 ºC FexSy CaS CaSO4 H2S SO2 Fig.4. Evolution of the sulphur distribution into the main sulphur-containing species at equilibrium conditions (H2S/N2 mixture as inlet gas). 0 10 20 30 40 50 60 70 80 90 100 Sulphur distribution (%) 0 10 20 30 40 50 60 70 80 90 100 Sulphur distribution (%) 0 10 20 30 40 50 60 70 80 90 100 Sulphur distribution (%) 0 10 20 30 40 50 60 70 80 90 100 Sulphur distribution (%)
33 Fig. 5. Back-scattered electron image of the ash resulting from experiment 2.
34 Fig. 6. XPS spectra in the S 2p region corresponding to the ash resulting from experiment 2.
35 (a) Dry synthetic gasification gas (b) Moist synthetic gasification gas (30 vol. % H2O) Gas feed ; Blank run: 800 ºC, 600 ºC Sewage sludge combustion ash: 800 ºC, 600 ºC Sewage sludge gasification ash: 800 ºC, 600 ºC Fig. 7. H2S breakthrough curves: evolution of the H2S flow rate (mLSTP·min-1) leaving the reactor when feeding the synthetic gasification gas. 0 50 100 150 200 250 0.00 0.05 0.10 0.15 0.20 0.25 H 2 S outlet flow rate (mL STP / min) Time (min) 0 20406080100120 0.00 0.05 0.10 0.15 0.20 0.25 H 2 S outlet flow rate (mL STP / min) Time (min)
36 (a) Dry synthetic gasification gas; 600 ºC (b) Dry synthetic gasification gas; 800 ºC (c) Moist synthetic gasification gas; 600 ºC (d) Moist synthetic gasification gas; 800 ºC FexSy CaS H2S Fig. 8. Evolution of the sulphur distribution into the main sulphur-containing species at equilibrium conditions (synthetic gasification gas as inlet gas). 0 10 20 30 40 50 60 70 80 90 100 Sulphur distribution (%) 0 10 20 30 40 50 60 70 80 90 100 Sulphur distribution (%) 0 10 20 30 40 50 60 70 80 90 100 Sulphur distribution (%) 0 10 20 30 40 50 60 70 80 90 100 Sulphur distribution (%)
37 Gas feed ; Blank run: 800 ºC, 600 ºC Sewage sludge combustion ash: 800 ºC, 600 ºC Sewage sludge gasification ash: 800 ºC, 600 ºC Fig. 9. Evolution of the outlet fractions of H2, CO, CO2 and C2Hx (dry basis) when feeding the moist synthetic gasification gas. 20 40 60 80 100 120 9 10 11 12 13 14 H 2 (vol. %) Time (min) 20 40 60 80 100 120 7 8 9 10 11 CO (vol. %) Time (min) 20 40 60 80 100 120 14 15 16 17 CO 2 (vol. %) Time (min) 20 40 60 80 100 120 0.0 0.5 1.0 1.5 2.0 C 2 H x (vol. %) Time (min)