scieee AI-readable full text Open interactive document viewer

Repositorio Institucional de Documentos

Abstract

Axions are well motivated particles proposed in an extension of the Standard Model (SM) as a solution to the CP problem in strong interactions. On the other hand, there is the category of axion-like particles (ALPs) which appear in diverse extensions of the SM and share the same phenomenology of the axion. Axions and ALPs are hypothetical neutral particles that interact weakly with matter, being candidates to solve the Dark Matter problem. CAST, the CERN Axion Solar Telescope is looking for solar axions since 2003. CAST exploit the helioscope technique using a decommissioned LHC dipole magnet in which solar axions could be reconverted into photons. The magnet is mounted on a movable platform that allows tracking the Sun ~1.5 hours during sunset and during sunrise. The axion signal would be an excess of X-rays in the detectors located at the magnet bore ends and thus low background detectors are mandatory. Three of the four detectors operating at CAST are of the Micromegas type. The analysis of the data of the three Micromegas detectors during the 2011 data taking campaign at CAST is presented in this thesis, obtaining a limit on the coupling constant of gag < 3.90 x 10-10 GeV-1 at a 95% of confidence level, for axion masses from 1 to 1.17 eV. CAST Micromegas detectors exploit different strategies developed for the reduction of the background level: the intrinsic radiopurity of the detectors; the improvements on the manufacturing process; the event discrimination and the shielding. Moreover, different test benches have been developed in order to understand the origin of the background, in which the set-up at the LSC (Laboratorio Subterráneo de Canfranc) is the one that shows the lower background level. The state of art in low background techniques is shown in the upgrades of the Micromegas detectors at CAST, described in this work, which has led to a reduction of a factor ~6 of the background levels in the Micromegas detectors. It translates in an improvement of the sensitivity of CAST in a factor ~2.5. Beyond CAST a new generation axion helioscope has been proposed: IAXO-the International Axion Observatory. IAXO will enhance the helioscope technique by exploiting all the singularities of CAST implemented into a large superconducting toroidal magnet, dedicated X-ray optics and ultra-low background detectors attached at the end of the magnet bores. A description of the IAXO proposal and the study of the sensitivity of IAXO are presented in this thesis. IAXO will surpass the sensitivity of CAST in more than one order of magnitude, entering into an unexplored parameter space area and by first time in a favored region for axions and ALPs. The use of thin cavities inside long magnets for relic axion detection is particularly appealing, because this type of magnets are already used by the axion community in experiments looking for solar axions, like CAST and are projected in future searches like IAXO. A directional effect could be observed by the use of long thin cavities properly tuned. This case has been studied in this thesis and could provide a strong identificative signature of the direction of the CDM axions. García Pascual, Juan Antonio; García Irastorza, Igor

Full text

2015 58 Juan Antonio García Pascual Solar Axion search with Micromegas Detectors in the CAST Experiment with 3He as buffer gas Departamento Director/es Física Teórica García Irastorza, Igor Director/es Tesis Doctoral Autor Repositorio de la Universidad de Zaragoza – Zaguan http://zaguan.unizar.es UNIVERSIDAD DE ZARAGOZA © Universidad de Zaragoza Servicio de Publicaciones ISSN 2254-7606 Departamento Director/es Director/es Tesis Doctoral Autor Repositorio de la Universidad de Zaragoza – Zaguan http://zaguan.unizar.es UNIVERSIDAD DE ZARAGOZA © Universidad de Zaragoza Servicio de Publicaciones ISSN 2254-7606 Departamento Director/es Juan Antonio García Pascual SOLAR AXION SEARCH WITH MICROMEGAS DETECTORS IN THE CAST EXPERIMENT WITH 3HE AS BUFFER GAS Director/es Física Teórica García Irastorza, Igor Tesis Doctoral Autor 2015 Repositorio de la Universidad de Zaragoza – Zaguan http://zaguan.unizar.es UNIVERSIDAD DE ZARAGOZA © Universidad de Zaragoza Servicio de Publicaciones ISSN 2254-7606 Departamento Director/es Director/es Tesis Doctoral Autor Repositorio de la Universidad de Zaragoza – Zaguan http://zaguan.unizar.es UNIVERSIDAD DE ZARAGOZA © Universidad de Zaragoza Servicio de Publicaciones ISSN 2254-7606 Solar Axion search with Micromegas Detectors in the CAST Experiment with 3 He as buer gas memoria presentada por Juan Antonio García Pascual para optar al grado de doctor en Física Laboratorio de Física Nuclear y Astropartículas Área de Física Atómica, Molecular y Nuclear Departamento de Física Teórica Universidad de Zaragoza Marzo 2015 A mis padres, a mi hermano y a mi sobrino. i Acknowledgments To be added 2 Chapter 1. Axions and Axion Like Particles Several experiments have been developed for axion and ALPs detection, based on laboratory regeneration searches, galactic halo searches (haloscopes) and solar searches (helioscopes), which will be briey discussed in this chapter. The helioscope technique, which is the main topic of this work, will be detailed. 1.2 The strong CP problem in QCD The Quantum Chromodynamics (QCD) is a gauge eld theory that describes the properties of the strong interactions between quarks and gluons, being the SU(3) component of the SM. A problem appears in QCD, the so-called strong CP problem. The theory predicts a CP-symmetry violation in strong interactions which have not been observed experimentally. The strong CP problem is closely related to the U(1) A problem of QCD and to its solution proposed by 't Hooft in 1976, some features of this problem will be briey described is this section. 1.2.1 The U(1) A problem and its solution The Lagrangian of QCD can be written as: LQCD =X n ¯ Ψn(iγµDµ−mn)Ψn−1 4Ga µνGµν a (1.1) where Ga µν are the eld strength tensors of the gluon elds with a color index a=1,...,8; Ψn are the quark elds with the quark avor n and mn the corresponding quark masses. Dµ is the covariant derivative dened as Dµ=∂µ−igTaGa µ where g is the coupling constant and Ta are the generators of the group of rotations of the quark elds in the color space. The QCD Lagrangian has a large global symmetry in the limit of vanishing quark masses mn→0 ; U(N) V× U(N) A , thus it is invariant under global axial and vector transformations. In reality u and d quarks masses could be considered approximately zero because mu, mdΛQCD , being ΛQCD the dynamical scale of the theory. So strong interactions are expected to be approximately U(2) V× U(2) A invariant. Indeed U(2) V = SU(2) V× U(1) V is the vector symmetry corresponding to isospin times baryon number, being a good approximate symmetry in nature. However the corresponding axial symmetries have not been observed, this phenomenon is understood because the SU(2) A symmetry is not preserved by the QCD vacuum and by spontaneous breaking we get the Nambu-Goldstone bosons (the pions), whose mass vanishes in the limit mu,d →0 . But there is no pseudoscalar state with vanishing mass corresponding to the Nambu-Goldstone boson of a U(1) A symmetry, this is known as the U(1) A problem [2]. The resolution of the U(1) A problem came through the realization by t'Hooft [3,4] that the QCD vacuum has a more complicated structure. The problem was bypassed by introducing an anomalous breaking of the U(1) A symmetry, adding an extra term Lθ to the Lagrangian: 1.2. The strong CP problem in QCD 3 Lθ=θg2 8π2Ga µν e Gµν a (1.2) here Ga µν is the gluon eld strength tensor and e Gµν a its dual, g the coupling constant and θ is an arbitrary angle between 0 and 2 π , which arises from the complicated structure of the QCD vacuum. More precisely, this means that the ground state is a superposition of an innite number of degenerate states |ni . The ground state, also called θ -vacuum can be expressed as: |θi= ∞ X n=−∞ e−inθ |ni (1.3) Taking into account the electroweak interaction one has to substitute θ in equation 1.2 by ¯ θ : ¯ θ=θ+θweak =θ+arg(detM) (1.4) where M is the quark mass matrix, thus the Lagrangian becomes: L¯ θ=¯ θg2 8π2Ga µν e Gµν a (1.5) and the QCD Lagrangian can be written as: LQCD =Lpert +L¯ θ (1.6) This additional term in the Lagrangian solves the U(1) A problem but is not invariant under CP, which leads to the strong CP-problem. 1.2.2 The strong CP problem For a non zero choice of ¯ θ in equation 1.5 one expect the CP symmetry to be violated as electro-weak interactions actually do, but experimentally the CP violation is not observed in strong interactions. This is the case of the electric dipole moment of the neutron dn (nEDM) which has been estimated by the MIT (Massachusetts Institute of Technology) bag model [5]: dn= 32.7×10−3e3mumdms mumd+mums+mdms R2¯ θ (1.7) here R is the bag radius R≃(140 MeV )−1 , the quark mass ratios are estimated to be md/mu= 1.8 , ms/md= 20 and the bag value ms≃300 MeV, obtaining dn= 8.2×10−16 ¯ θ e cm. Experimentally the nEDM is bounded to |dn|<2.9×10−26 e cm (90 % CL) [6], it constraints ¯ θ≤10−10 . Such small value of ¯ θ is allowed in the theory, however the problem is beyond the unexplained smallness of ¯ θ because it implies that the two contributions of the equation 1.4, which are in principle unrelated, have to cancel 4 Chapter 1. Axions and Axion Like Particles each other with a precision of 10−10 . The strong CP problem is why this ¯ θ angle coming from the strong and weak interactions, is so small. There are mainly three solutions proposed in order to solve the CP-problem: the rst and least likely implies zero quark masses, the second one is to set θ= 0 , imposing CP symmetry in the QCD Lagrangian and the third and more compelling solution is the Peccei-Quinn mechanism that will be described below. 1.2.3 The Peccei-Quinn solution The Peccei-Quinn (PQ) solution was proposed in 1977 [7,8]. In order to equal ¯ θ to zero it postulates a new global and chiral symmetry U(1) PQ (the PQ symmetry) that is spontaneously broken at the energy scale of the symmetry fa . It implies the existence of a new eld a which appears as the pseudo Nambu-Goldstone boson of the new symmetry, the axion. This new eld yields an additional term La in the QCD Lagrangian LQCD LQCD =Lpert +L¯ θ+La (1.8) where La is given by La=−1 2∂µa∂µa+Lint +Ca a fa g2 32π2Ga µν ¯ Gµν a (1.9) The rst term take account of the kinetic energy, the second term represent further interactions of the axions and the third term introduces the axion eld a and its coupling to gluons. Ca is a parameter dependent of the model, g is the strong coupling constant and fa is the energy scale of the spontaneous breaking of the PQ symmetry. The third term in equatiom 1.9 provides an eective potential for the axion eld Veff , so the vacuum expectation can be obtained by calculating its minimum. ∂Veff ∂a =−Ca g2 32π2faGa µν ¯ Gµν ahai = 0 (1.10) Thus the value for the vacuum expectation of the axion eld hai , can be written as: hai=−fa Ca ¯ θ (1.11) It solves the strong CP problem by canceling the ¯ θ term for any value of fa , providing a dynamical solution to the problem. Expanding Veff around its minimum the axion get mass: m2 a=∂2Veff ∂2a=−Ca g2 32π2fa ∂ ∂a Ga µν ¯ Gµν ahai (1.12) 1.3. Axion properties. 5 So far the PQ mechanism is the more elegant solution to the strong CP problem and could be experimentally proven by the discovery of a new particle: the axion. 1.3 Axion properties. The PQ solution xes some properties of the axion that only depends on the energy scale of the spontaneous breaking of the symmetry fa . These properties are the axion mass ma and the coupling constant gai of the axion to other particles denoted by i , both of them are inversely proportional to fa . ma∝1 fa , gai ∝1 fa (1.13) 1.3.1 Axion coupling to matter Although some of the other properties of the axions are model-dependent, generically the axion couples with gluons and photons, which is a consequence of the former, it could also interact with fermions. Some features of these interactions will be described below. 1.3.1.1 Coupling to gluons The coupling of axion with gluons is given by the third term in equation 1.9, by the expression: LaG =αs 8πfa aGa µν e Gµν a (1.14) with the strong ne-structure constant αs . Due to its coupling with gluons, axions can acquire mass by mixing with pions ma=mπfπ farz (1 + z+w)(1 + z)≃6 meV 109 GeV fa (1.15) here mπ= 135 MeV is the pion mass and fπ≃92 MeV the pion decay constant, z and w are the quark masses ratios mu/md and mu/ms respectively. The coupling of gluons to axion is generic to all the models, thus the axion mass mass, given by 1.15, is inversely proportional to fa . 1.3.1.2 Coupling to photons Axion couples to photons through the mixing of pions with axions. The contribution of the axion-photon interaction to the Lagrangian is given by the expression: Laγ =−1 4gaγFµν ¯ Fµνa=gaγ ~ E~ Ba (1.16) 6 Chapter 1. Axions and Axion Like Particles here gaγ is the coupling constant from axions to photons, Fµν is the electromagnetic eld-strength tensor and ¯ Fµν its dual, ~ E and ~ B are the electric and magnetic elds and a is the axion eld. A further contribution in the coupling can appear in models in which standard fermions carry PQ-charges in addition to the electric charges. The axion-photon coupling constant can be written as: gaγ =α 2πfaE N−2(4 + z+w) 3(1 + z+w) (1.17) here α is the ne structure constant, E/N is the ratio between the electromagnetic E and color N anomalies, z and w are the quark mass ratios introduced in equation 1.15. Since E/N is a model dependent factor the terms in the parenthesis of equation 1.17 are usually presented in literature as the coecient Cγ . gaγ =α 2πfa Cγ, Cγ=E N−2(4 + z+w) 3(1 + z+w)=E N−1.92 ±0.08 (1.18) The axion-photon coupling is generic to all the models and most of axion searches strategies are based on this interaction. 1.3.1.3 Coupling to fermions Depending on the model, axions can also couple with fermions, this interaction is postulated in the second term of the Lagrangian from equation 1.9 1 , in which the interaction of an axion to a fermion f is given by: Laf =gaf 2mf¯ Ψfγµγ5Ψf∂µa (1.19) where Ψf is the fermion eld, mf the fermion mass and gaf the axion-fermion coupling constant, that can be written as [9]: gaf =Cfmf fa (1.20) The dimensionless combination of gaf plays the role of a Yukawa coupling with an eective PQ-charge Cf and a ne-structure constant of the axion αaf =g2 af /4π can be dened. The axion could also couple to electrons at tree level, this process is possible if electrons carry PQ-charge, thus the coecient Ce6= 0 . It is the case of the DSFZ model (see section 1.3.2.2) in which the axion-electron coupling constant gtree ae is given by gtree ae =Ceme fa = 0.85 ×10−10maCe eV −1 (1.21) 1 Note that the second term Lint in the Lagrangian of equation 1.9 is dened as Lint =Laγ +Laf 1.3. Axion properties. 7 Even if the eective PQ-charge Ce= 0 , axions could couple to electrons in a higher order. This is the so-called radiatively induced coupling at the one loop level, however the grad ae coupling is weaker than gtree ae . Finally an eective axion-nucleon coupling could be considered since there are no free quarks below the QCD scale ΛQCD ≈200 MeV. There are two contributions to the axion-nucleon coupling: the coupling to light quarks at tree level and the mixing with pions. The coupling constant is given by gaN =CNmN fa = 1.57 ×10−7maCN eV −1 (1.22) where CN is a model-dependent coecient of the interaction in which the coupling to protons and neutrons have dierent contributions. 1.3.1.4 Further processes There are processes involving axions quite relevant in the frame of astrophysics. The predominant emission process of axion in stars is the Primako eect γ+Ze → Ze +a , in which a photon can be converted into an axion in presence of strong electromagnetic elds (e.g. the electric eld of the charged particles inside the plasma). This process is quite relevant in axion searches because axions could be reconverted into photons (and detected) inside a strong magnetic eld via inverse Primako eect. Further processes in axion models with tree-level coupling to electrons might dominate the axion emission in white dwarfs and red giants. These processes are the Compton γ+e−→e−+a and the Bremsstrahlung emission e−+Ze →Ze+e−+a . Also is interesting the axion-nucleon Bremsstrahlung N+N→N+N+a which could be relevant in supernova explosions. These processes and its implications in astrophysics will be revisited in section 1.3.3 1.3.2 Axion models Axion could couple to dierent particles as it was presented in the previous section. These interactions are strongly model dependent and can be divided in two dierent trends: the rst postulated axion also referred to visible or PQWW (Peccei-Quinn- Weinberg-Wilczek) axion and the invisible axion model which assumes a lighter axion. 1.3.2.1 Visible axion model In the original PQ model [10], the U(1)PQ symmetry was broken at the electroweak scale fa= Λweak with Λweak ≃250 GeV. It implies axion masses larger than 150 keV and relative strong coupled to baryonic matter and radiation. Such axions would have been produced and detected in reactor and accelerator experiments. The non 8 Chapter 1. Axions and Axion Like Particles experimental observation of the PQWW axion together with the astrophysical limits on the evolution of the red giants ruled out the existence of the visible axion. 1.3.2.2 Invisible axion models After the dismiss of the visible axion, a new invisible axion model was postulated. Indeed the breaking scale of the PQ symmetry fa is an arbitrary value that could be larger than the electroweak scale. There are mainly two dierent invisible axion models, the KSVZ (Kim-Shifman-Vainshtein-Zakharov) and the DFSZ (Dine- Fischles-Srednicki-Zhitnitskii), in both of them the axion is light and interact weakly with matter. (eV) a m -5 10 -4 10 -3 10 -2 10 -1 10 1 10 ) -1 (GeV γa g -12 10 -11 10 -10 10 -9 10 -8 10 -7 10 KSVZ (E/N = 6) KSVZ (E/N = 0) DFSZ (E/N = 8/3) KSVZ (E/N = 2) (eV) a m 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 ) -1 GeV -10 10× ( γa g 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 KSVZ (E/N = 6) KSVZ (E/N = 0) DFSZ (E/N = 8/3) KSVZ (E/N = 2) Figure 1.1: Axion-photon coupling constant as a function of the axion mass for invisible axion models. Three lines for the KSVZ model are shown: E/N = 6 (solid blue line); E/N = 0 (dotted green line) and E/N = 2 (dashed black line). Also the DFSZ model with E/N = 8/3(dashed red line) has been drawn. KSVZ model In this model [11,12] the interactions of axions with matter only occurs via the axion-gluon coupling and ordinary quarks and fermions do not interact with axions. A new heavy quark Q has to be introduced, being the unique particle which carries PQ charge in the KSVZ model. However the axion would still interact with the light quarks due to the color anomaly. The axion-photon coupling is given by 1.3. Axion properties. 9 equation 1.17 in which E/N is a model dependent parameter, in general E/N in the KSVZ model is given by: E N= 6Q2 heavy (1.23) where Qheavy is the electric charge of the new heavy quark Q and can take values of Qheavy = 2/3,−1/3,1,0 . The most common values used in the literature are E/N = 2 , E/N = 6 and the standard KSVZ model with E/N = 0 , that are shown in gure 1.1. DFSZ model In contrast with the KSVZ model, in the DSFZ model [13] the fundamental fermions carry PQ charge and no exotic quark is needed. The disadvantage of this model is that a ne tuning is necessary in order to obtain a breaking scale larger than the electroweak scale. On the other hand, the advantage of this model is that it can be easily introduced in Grand Unication Theories (GUT). In this case the model dependent parameter takes the value E/N = 8/3 (see gure 1.1). 1.3.3 Summary of relevant axion constraints The axion mass is initially arbitrary since the strong CP problem is solved for any value of the breaking scale fa . Due to its implications in astrophysics, cosmology and particle physics the axion has been thoroughly studied and the most relevant constraints come from astrophysical considerations. Indeed axions could be produced in hot and dense environments like stars, globular clusters and white dwarfs. 1.3.3.1 Solar model Axions could be produced in the solar plasma via Primako eect and electron Bremsstrahlung processes, being an additional energy loss channel that could reduce the lifetime of the star. The most relevant constraint comes from the fact that the emission of axions from the Sun implies an increment of the nuclear burning and consequently of the solar temperature distribution, that leads an increase on the 8 B neutrino ux [15]. With these considerations the axion-photon coupling is constrained to gaγ ≤7×10−10 GeV −1 . Also the axion-electron coupling is constrained to gae ≤2.5×10−11 GeV −1 by the Bremsstrahlung collisions. 1.3.3.2 Globular clusters A globular cluster is a spherical collection of ∼106 of densely packed stars that were formed about the same time. Two dierent types of stars in globular clusters are especially interesting for the axion bounds, the horizontal branch (HB) stars and the red giants branch (RGB). The RGB stars have degenerated helium burning core and a hydrogen burning shell. When the RGB helium core becomes hot and dense enough it rapidly increases the rate of fusion and becomes a HB star. Thus the 10 Chapter 1. Axions and Axion Like Particles axion production via Primako eect should be larger in HB stars in comparison with RGBs, adding a new energy loss channel which is negligible for RGB stars. So the population of RGB stars should be relatively larger than the population of HB stars inside the globular clusters. By computing the observed population of HB and RGB stars [9], the axion-photon coupling is constrained to gaγ .10−10 GeV −1 , being the most restrictive astrophysical limit on the coupling constant. Also the RGB stars are supposed to have larger brightness if the degenerate helium core losses to much energy by emission of axions or neutrinos. In this case the axion emission would be dominated by electron-Bremsstrahlung processes. Observational measurements in the globular cluster M5 [16] lead to a limit on the axion-electron coupling of gae <4.7×10−13 GeV −1 . 1.3.3.3 White dwarf cooling White dwarfs (WD) are a remnant of initial low massive stars, made of a degenerate carbon-oxygen core and a helium burning shell. A WD is very hot when is formed, but since it has no energy source it gradually cool down, by rst the emission of neutrinos and later by photons from the surface. Also WD could increase its cooling speed by the emission of axions generated mainly by axion-Bremsstrahlung processes. This axion emission could be constrained by the comparison of the observed cooling speed with WD models. One special case is the study of the cooling of the ZZ Ceti stars [17] in which the most restrictive limit on the axion-electron coupling gae <1.3×10−13 GeV −1 has been obtained. 1.3.3.4 Supernova 1987 A A supernova (SN) is a stellar explosion that expels a big quantity of stellar material with a great force. There are dierent types of SN, the most interesting one is the type II SN. When a star is massive enough to burning its carbon-oxygen core (in contrast with white dwarfs), it rapidly consumes the carbon core producing heavier nuclei and increasing the core size, at some point the core exceeds the Chandrasekhar limit 2 [18] and the star collapses. A cataclysmic implosion takes place within seconds generating a huge quantity of radiation and a burst of neutrinos. Axions could be emitted from the core of a type-II SN via axion-nucleon Bremsstrahlung shortening the neutrino burst. For a very small axion-nucleon coupling gaN , the duration of the burst is not aected, but by increasing the coupling the burst duration becomes shorter until it reaches its minimum (free streaming regime in gure 1.2). Also if gaN increases further, axions are not able to escape (trapped regime in gure 1.2) and the burst duration becomes unaected. The SN 1987A gave the rst chance to observe directly the neutrino emission from 2 The Chandrasekhar limit is the maximum mass that can be supported by electron degeneracy pressure without suering a gravitational collapse 1.3. Axion properties. 11 Figure 1.2: Relative duration of a type II supernova neutrino burst as a function of the axion-nucleon coupling gaN . The free streaming region represent axions emitted from the core, while in the trapping regime axions are not able to escape. The dotted line is a continuation to guide the eye. Plot taken from [17]. an extragalactic source, it was measured by the neutrino experiments IMB 3 and Kamiokande II 4 operating at this time. A total of 20 neutrinos ¯νe were detected with a burst duration of ∼10 s which ts the expectations without an extra axion cooling. These measurements lead to an excluded range on the axion-nucleon coupling of 3×10−10 .gaN .3×10−7 [19]. However the low statistics accumulated from the neutrino burst and some incompatibilities in the measurements of the two dierent experiments create a big uncertainty in this excluded range. 1.3.4 Axions as a Dark Matter candidate There are several observational evidences of the presence of Dark Matter (DM) in the Universe, like the rotation curves of the spiral galaxies, gravitational lensing and uctuations in the Cosmic Microwave Background (CMB). According with the latest results of the PLANCK experiment [20] the Universe is composed of a 4.2% of baryonic matter, a 27.2% of DM and a 68.6% of Dark Energy (DE); in other words, the most part of the Universe has an unknown nature. The DE takes account of the accelerated expansion of the Universe, but his nature is not well understood, it can be explained as a cosmological constant, vacuum energy or a quintessence eld. The DM would be composed by electrically neutral particles which interact weakly with matter. Popular candidates to DM are the Weakly Interacting Massive Parti- 3 Irvine-Michigan-Brookhaven detector 4 Kamioka Nucleon Decay Experiment 18 Chapter 1. Axions and Axion Like Particles from 1.9≤ma≤3.3µ eV [36], in a second phase the microwave receivers was substituted by SQUID (Superconducting QUantum Interference Device) in order to improve the sensitivity and scanning a mass range from 3.3≤ma≤3.53 µ eV [37] (see gure 1.5 bottom). However these results assume that axions are the main component of cold DM in the Universe. 1.6.1.2 Telescopes Although the decay of the cold DM axions to two-photons is expected to be extremely odd, it could be detected in thermally produced axions in the eV regime. The signal will be a closely monochromatic line emitted from galaxies and could be observed by telescopes used in astrophysics. Dierent works have excluded axion masses of 3.ma.8 eV [38,39]. 1.6.2 Laboratory searches In laboratory experiments photons could be converted into axions or ALPs inside a strong magnetic eld via Primako eect. The advantage of this technique is that do not rely in astrophysical or cosmological assumptions in the origin of the axions or ALPs. On the other hand the sensitivity of this kind of experiments is usually lower than other search strategies. There are mainly two dierent techniques in laboratory searches: the Light Shining through Wall (LSW) and the polarization experiments. 1.6.2.1 LSW searches LSW or photon regeneration experiments [40] use high intensity laser beams inside a strong transverse magnetic eld in order to produce axions or ALPS. Then a opaque wall is placed to block the photons. On the other side of the wall another magnetic eld allows the axions or ALPs, which could easily pass the wall, to transform again into photons that can be detected. Several experiments have excluded signicant regions in the ALP parameter space: the LIPSS 6 [41] experiment at the Jeerson Laboratory, the BMV 7 [42] collaboration, the GammeV 8 [43] experiment at Fermilab, the OSQAR 9 [44] experiment working at CERN and nally the most sensitive LSW so far, the ALPS 10 [45] experiment at DESY. The results of all these experiments are shown in gure 1.6. Although the experiments related before use laser beams, the same principle of detection could be adapted to the microwave regime. It is the case of the CROWS 11 experiment [46] at CERN. 6 LIght Pseudoscalar or Scalar Search 7 Birefringence Magnetic du Vide 8 Gamma to mili-eV particle search 9 Optical Search for QED vacuum magnetic birefringence 10 Axion-Like Particle Search 11 CERN Resonant Weakly Interacting sub-eV Particle Search 1.6. Axion and ALPs searches 19 Figure 1.6: Exclusion limits for axion like particles in different LSW and polarization experiments. The dashed and dotted lines correspond to the PVLAS experiment. Plot taken from [45]. 1.6.2.2 Polarization experiments In contrast with LSW experiments, it is possible to obtain an axion signal in the laser beam itself. When a polarized light passes through a transverse magnetic eld it could generate axions or ALPs and thus it would induce a detectable small rotation and ellipticity in the laser beam. Experiments like the BFRT 12 [47] at the Brookhaven National Laboratory and the PVLAS 13 experiment at the the Legnaro National Laboratory exploited this technique and excluded some regions of the parameter space (see gure 1.6). Moreover the PVLAS experiment reported a signal, but it was ruled out later, interpreted as an artifact of an instrument [49]. 1.6.3 Solar axion searches The Sun is expected to be an powerful axion source, as it was presented in section 1.3.3.1. Solar axions could be detected in the laboratory via inverse Primako eect. Two dierent techniques for the detection of solar axions have been developed: helioscopes and the Bragg scattering experiments. 12 Brookhaven Fermilab Rutherford Trieste collaboration 13 Polarizzazione del Vuoto con LASer 20 Chapter 1. Axions and Axion Like Particles 1.6.3.1 Helioscopes The helioscope technique was proposed by Sikivie [33] in 1983. The principle of detection is to reconvert the solar axions into photons in a intense transversal magnetic eld. Solar axions may have energies in the keV regime, thus the expected signal are X-rays in the detectors located at the edges of the magnet. Helioscopes can cover axion masses in a wide range of the parameter space (up to ∼ eV) because contrary to haloscopes the signal is independent of the axion mass. The helioscope technique will be revisited in more detail in section 1.7 (eV) a m -3 10 -2 10 -1 10 1 10 ) -1 (GeV γa g -10 10 -9 10 -8 10 DAMA (90%CL) CDMS EDELWEISS SOLAX, COSME Tokyo helioscope Lazarus et al. Axion models KSVZ [E/N = 0] DFSZ CAST -3 10 -2 10 -1 10 1 10 Figure 1.7: Excluded region for different experiments based on solar axion searches at 95% of C.L. Dashed lines correspond to Bragg scattering experiments; from top to bottom: SOLAX & COSME (black), CDMS (brown), EDELWEISS (blue) and DAMA (red). The solid lines represent helioscopes searches: Lazarus et al. (blue), Tokyo Axion Helioscope (green) and CAST (red). Typical axion models are contained in the orange band, the solid gray lines correspond to the KSVZ model (E/N = 0) and the DFSZ model (E/N = 8/3). Dierent experiments based on the helioscope technique have been developed, the rst one was performed by Lazarus et al. [50] validating the technique. Later on the Tokyo Axion Helioscope (SUMICO) [51] applied the same principle of detection increasing the sensitivity. Finally the CERN Axion Solar Telescope (CAST) started in 2003 being the most sensitive helioscope until now, the excluded regions of these experiments together with the Bragg scattering searches are shown in gure 1.7. 1.7. Solar axions and the helioscope technique 21 The CAST experiment, which is the main topic of this work, will be detailed in chapter 2. 1.6.3.2 Bragg scattering searches Crystalline detectors can also be used for solar axion searches. The axion-photon conversion could take place in the Coulomb eld of the nuclei in the crystal lattice. The conversion occurs when the angle of the incident axions fullls the Bragg condition with the plane of the crystal. Thus the expected signal is a characteristic Bragg pattern in the detector. Even though there are not much dedicated experiments, a great number of underground experiments developed for WIMP searches have been looked for these patterns. Such as SOLAX 14 [52], COSME 15 [53], DAMA 16 [54], CDMS 17 [55] and more recently EDELWEISS 18 [56]. However the sensitivity of this technique cannot compete with dedicated helioscope experiments, as is shown in gure 1.7. 1.7 Solar axions and the helioscope technique Axions could be generated in the core of the Sun, being the most powerful axion source closest to the Earth. The expected production of axions in the well known Solar Model will be described. The detection of the solar axions comes through its conversion into photons inside strong magnetic elds in which the probability of the axion-photon conversion has an important role and will be detailed. 1.7.1 The Solar Model and the axion production The solar axion ux can be extracted from well established Standard Solar Model. The most relevant channel in the axion emission comes from the Primako conversion which is dominant in hadronic axion models such as the KSVZ model. In the case of non-hadronic axions (DFSZ model) with a tree level interaction with electrons, other processes have to be taken into account: Bremsstrahlung, Compton and axion recombination. The contribution of these channels could be considerably larger than the Primako emission. However in the helioscope technique only the Primako contribution is usually taken into account because it is more reliable to suppose the same processes involving the generation and detection of the axions. Also the astrophysical constraints on gae are more restrictive than the limits that could be in principle reached with helioscopes. 14 SOLar AXion search in Argentina 15 Germanium detector located in the Canfranc Underground Laboratory 16 DArk MAtter searches, operating at Gran Sasso 17 Cryogenic Dark Matter Search, located in Soudan 18 Expèrience pour DEtecter Les Wimps En Site Souterrain, at Modane 22 Chapter 1. Axions and Axion Like Particles 1.7.1.1 Hadronic axion emission Axions could be generated in the core of the Sun inside the strong electric elds from the charged particles of the solar plasma by the process γ+Ze →Ze +a . Thus the energies of the converted axions correspond to the blackbody radiation of the core of the Sun (keV regime). The Primako process in non-relativistic conditions is relevant when the mass of electrons and nuclei are larger than the energies of the ambient photons. Following [9], neglecting recoil eects, the dierential cross section is given by: dσa→γ dΩ=g2 aγZ2α 8π|~pγ×~pa|2 ~q 4 (1.25) here Z is the charge ( Ze ) of the involved particle, α is the ne structure constant, ~pγ and ~pa are the momentum of the photon and the axion respectively and ~q =~pγ−~pa is the momentum transferred. The cut-o of the Coulomb interaction in vacuum for ma6= 0 is given by the minimum momentum transfer qmin =m2 a/2Ea for maEa and the total cross section can be written as: σa→γ=g2 aγZ21 2ln 2Ea ma−1 4 (1.26) In a plasma, the Coulomb potential is cut-o due to screening eects and thus the dierential cross section is modied by an additional factor in equation 1.25. dσa→γ dΩ=g2 aγZ2α 8π|~pγ×~pa|2 ~q 4|~q 2| k2 s+|~q2| (1.27) In a non degenerate medium, the screening scale ks is given by the Debye-Hückel formula ks=4πα TnB Ye+X j Z2 jYj  (1.28) where T is the temperature of the solar plasma, nB is the baryon density and Ye and Yj are respectively the fraction of electrons and dierent nuclear species j per baryon. By using equations 1.27 and 1.28, the total scattering cross section can be calculated. Summing over all the targets, the transition rate Γγ→a of a photon with energy Eγ into an axion of the same energy Ea≡Eγ is obtained. Γγ→a=gaγTk2 s 32π1 + k2 s 4Ealn 1 + 4Ea k2 s−1 (1.29) 1.7. Solar axions and the helioscope technique 23 here the eective photon mass and axion mass are negligible in comparison with Ea . The dierential axion ux at Earth can be calculated by the convolution of the transition rate and the blackbody emission of the Sun. dΦa dEa =1 4πd2 ZR 0 d3~r 1 π2 E2 a eEa/T −1Γγ→a (1.30) being d= 1.5×108 km the average distance from the Earth to the Sun and R= 7.0×105 km the solar radius. Using the Standard Solar Model from [57] an analytical approximation to the axion dierential spectrum may be derived [59]. dΦa dEa = 6.02 ×1010 gaγ 10−10 GeV −12 (Ea/ keV )2.481 e−Ea/1.205keV  cm −2 s −1 keV −1 (1.31) (keV) a E 0 2 4 6 8 10 12 14 ) -1 keV -1 s -2 cm 10 Differential solar axion flux (10 0 1 2 3 4 5 6 7 8 Bahcall et al 2004 Bahcall et al 1982 Figure 1.8: Differential solar axion flux at Earth for hadronic axion models, the calculations have been made using a coupling constant of gaγ = 10−10 GeV−1. Two different lines are drawn, corresponding to the solar model from 1982 [58] (dotted black line) and an updated solar model from 2004 [57] (solid red line). The dierential solar axion ux is proportional to the coupling constant with an average energy of < Ea>= 4.2 keV and a maximum around 3 keV (see gure 1.8). Also the total axion luminosity of the Sun can be estimated: La= 1.85 ×10−3gaγ 10−10 GeV −12 L (1.32) where L is the solar luminosity. 24 Chapter 1. Axions and Axion Like Particles 1.7.1.2 Non-hadronic axion emission In non hadronic axion models with an axion-electron coupling at tree level (DFSZ model), the solar axion emission is dominated by the axion-electron coupling. Following the work of Redondo [60], the most important production comes from the interactions: electron-ion Bremsstrahlung (e+I→e+I+a) , electron-electron Bremsstrahlung (e+e→e+e+a) , Compton scattering (γ+e→γ+e+a) , axiorecombination (e+I→I−+a) and axio-deexcitation (I∗→I+a) . The Feynman diagram of these processes together with the Primako process are shown in gure 1.9. Figure 1.9: Feynman diagrams of the most relevant solar axion production channels. Plot taken from [60]. The Bremsstrahlung or free-free () electron transitions on hydrogen and helium nuclei dominates solar ux together with the electron-electron (ee) Bremsstrahlung. The axio-recombination, also know as free-bound (fb) electron transitions, of metals (mainly O, Ne, Si, S and Fe) has a signicant contribution. The axio-deexcitation, or bound-bound (bb) electron transitions, is dominated by Lyman transitions (mostly Lyα ) being signicant in the case of iron ( ∼6.4 keV). The Compton (C) production process has a poor contribution. The emission rate of solar axions for all the processes described before, can be expressed as: ΓP a=Γff a+Γfb a+Γbb a+ΓC a+Γee a (1.33) where ΓP a is the emission rate of the sum over all the process. Electron-ion Bremsstrahlung, axio-recombination and axio-deexcitation In processes in which a photon is emitted when a electron makes an atomic transition ei→ef . The spin-averaged matrix element of emitting an axion of energy Ea is 1.7. Solar axions and the helioscope technique 25 proportional to the analogous matrix element of emitting a photon of the same energy. Thus in this case the emission rates of photons and axions are proportional and can be formulated as: ΓP,i a(Ea) ΓP,i γ(Ea)=1 2 g2 aeE2 a e2m2 e ;i= , fb, bb (1.34) In the case of the electron-ion Bremsstrahlung (), the photon production rate is given by: ΓP,ff a(Ea) = α3Z264π2 3√2π nZne √Tm3/2 eE3 a e−Ea/T F(Ea, ks/p2meT) (1.35) where Z is the charge of the involved nuclei and nZ its number density, ne is the electron density, F(Ea, ks) take account of the screening eects and ks is the screening scale introduced in equation 1.28. Therefore the transition rate for electron- Bremsstrahlung process can be derived: ΓP,ff a(Ea) = α2g2 aeZ28π 3√2π nZne √Tm7/2 eEa e−Ea/T F(Ea, ks/p2meT) (1.36) Electron-electron Bremsstrahlung In this case the expression 1.34 is not valid, because the photon emission is highly suppressed in comparison with electron-ion process. The production rate involving this process has been calculated in [9] and is given by: ΓP,EEO a(Ea) = α2g2 ae 4π 3 n2 e √Tm7/2 eEa e−Ea/T F(Ea,√2ks/p2meT) (1.37) Compton scattering In the non-relativistic limit, the cross section of the axion production in Comptonlike processes is given by [19]: σa,C =αg2 aeE2 a 3m4 e (1.38) Thus the transition rate can be expressed as: ΓP,C a(Ea) = αg2 aeE2 a 3m2 e ne eEa/T −1 (1.39) here the ratio between the photon and the axion production rate is slightly dierent from equation 1.34. 26 Chapter 1. Axions and Axion Like Particles ΓP,C a(Ea) ΓP,C γ(Ea)=g2 aeE2 a e2m2 e (1.40) All the contributions to the axion emission presented before can be expressed in terms of the photon absorption coecient with the exception of the electron-electron Bremsstrahlung. Thus the total axion ux in earth can be calculated analogous to equation 1.30 dΦa dEa =1 4πd2 ZR 0 d3~r4πE2 a 2π3ΓP a(Ea) (1.41) where ΓP a is the emission rate of all the processes presented in 1.33, this term depends on the local parameters of the solar plasma. Integrating equation 1.41 using the solar model from [61] and the dierent contributions presented before, the axion ux at Earth has been extracted [60] and is shown in gure 1.10. Figure 1.10: Differential solar axion flux at Earth in non-hadronic processes using a coupling constant of gae = 10−13. Different contributions have been drawn: atomic recombination plus atomic deexcitation (FB + BB), Bremsstrahlung process (FF) and Compton. The solid blue line is the Primakoff emission with gaγ = 10−12 GeV−1which has been multiplied by a factor 50 to make it visible. Plot taken from [60] 1.7. Solar axions and the helioscope technique 27 Contrary to the hadronic axion emission, the total axion ux cannot be approximated to an analytical formula, due to the narrow lines from the bound-bound and free-bound transitions. Also the maximum of the spectrum is reached at lower energies ( ∼ 1 keV) in contrast with the Primako emission. On the other hand the Bremsstrahlung (B) and Compton (C) processes could be approximated to an analytical formula dΦa dEaB = 2.63×109gae 10−13 2Ea/ keV 1+0.667(Ea/ keV )1.1278 e−0.77Ea/keV  cm −2 s −1 keV −1 (1.42) dΦa dEaC = 1.33 ×107gae 10−13 2(Ea/ keV )−2.987 e−0.776Ea/keV  cm −2 s −1 keV −1 (1.43) here the Bremsstrahlung ux includes electron-ion and electron-electron processes. 1.7.2 Probability of the axion-photon conversion In the helioscope technique solar axions could be converted into photons inside strong magnetic elds by the inverse Primako eect. This conversion is only effective when the magnetic eld is transversal to the direction of propagation of the incoming axion. The wave equation of a particle propagating along the z-axis in a transverse magnetic eld B is given in [62] and can be formulated as: i∂zAk a= Ea−m2 γ 2Ea−iΓ 2gaγ B 2 gaγ B 2Ea−m2 a 2Ea!Ak a (1.44) here Ak is the amplitude of the photon eld parallel to the magnetic eld, a is the amplitude of the axion eld, Γ is the inverse absorption length for the photons and mγ is the eective photon mass, which is given by the plasma frequency of the medium. A rst-order solution using a perturbative approach has been derived in [59] and is given by the expression: < Ak(z)|a(0) >=gaγ 2 exp −Zz 0 dz0Γ 2×Zz 0 dz0B exp iZz0 0 dz00 "m2 γ−m2 a 2Ea−iΓ 2#! (1.45) In general B , Γ and mγ are functions of z . By considering the case in which the magnetic eld B and the density are uniform and Γ and mγ are constant. The conversion probability Pa→γ of an axion into a photon inside a magnetic eld with an eective length z=L , can be derived: 34 Chapter 2. The CAST experiment Figure 2.3: Standard cross section of a LHC dipole magnet. Figure 2.4: Orientation of the magnetic field in a dipole magnet. vated, generating a controlled increase of the magnet temperature that is uniformly distributed. The rise of the temperature provokes an overpressure in the system and the helium is purged in order to prevent damages in the magnet. 2.2. Technical description 35 2.2.2 The tracking system The tracking system is crucial for the required precision of CAST while is pointing the Sun. For this purpose an accurate hardware and software were designed [66]. Also two complementary alignment test are performed regularly, the grid measurements and the Sun lming. All these features will be described in this section. 2.2.2.1 Hardware The CAST magnet is mounted on a movable platform that allows a vertical movement of ±8◦ (polar angle) and from 46◦ to 133◦ in horizontal (azimuth angle). The rotary pivot is placed underneath the MFB in order to ensure the stability of the cryogenics while the magnet is moving. The MRB side of the magnet is supported by a trolley with four wheels mounted on rails, which allows the horizontal movement (see gure 2.2). The vertical movement is performed by two jacks spinning around two lifting screws mounted on the trolley. Figure 2.5: Left: Vertical encoder and lifting jacks. Right: Driving wheel and horizontal encoder. The horizontal motion is performed by a driving wheel connected to a motor, for the vertical movement another motor control the speed of the lifting jacks. Both horizontal and vertical motions are monitored by two dierent motor encoders (see gure 2.5). The values of the encoders can be translated in polar and azimuthal angles to check the orientation of the magnet. 36 Chapter 2. The CAST experiment 2.2.2.2 Software In order to perform the Solar tracking a Labview based software was developed (see gure 2.6). The program calculates the position of the Sun using the NOVAS 4 [67] software. During the tracking the program communicates with the hardware. It calculates the position of the Sun in the next minute, then the motor velocities are modied using the position of the magnet from the motor encoders. The expected and the real tracking position are monitored and thus the precision of the tracking is checked every minute. Figure 2.6: Labview based tracking program of the CAST experiment 2.2.2.3 Tracking system alignment The precision of the solar tracking is essential in the helioscope technique. Two dierent methods are used in order to check the reference position of the magnet and the real one: the grid measurements and the Sun lming. The Sun lming consists in monitor the visible light of the Sun through a window in the experimental area. These measurements only can be performed in March and September, when the Sun is reachable. For this purpose a photo camera is aligned with the magnet and takes photos of the Sun during morning trackings. Afterwards a software is used to compare the deviation of the center of the Sun using the reference position of the camera. 4 Naval Observatory Vector Astrometry Software 2.2. Technical description 37 Figure 2.7: Left: Photo of the Sun during the Sun filming and analysis program that calculates the center of the solar disc. Right: 2011 grid results in comparison with the 2007 grid for the two magnet bores V1 (blue points) and V2 (red points). The green circle corresponds to a deviation of 1 arcmin and the red circle represents a 10% of the solar radius. The units of the deviation are in mm per 10 m. The grid measurements are performed at least once every year. It consist in measuring dierent reference positions of the magnet and compare with dierent years. In case of any deviation of the reference position the new grid can be implemented in the software program. 2.2.3 The vacuum system The vacuum system at CAST can be divided in dierent subsystems depending on its purpose (see gure 2.8). The cryostat vacuum isolates the magnet from the environmental temperature and the general vacuum line separates the magnet from the detectors. At the end of the line four gate valves are installed (VT1, VT2, VT3 and VT4), one per detector bore end. During normal operation the gate valves are open, but they can be closed separately in case of failure. Finally in the detector side of the gate valves there are dierent vacuum subsystems for the dierent detector lines. 2.2.4 The gas system The sensitivity to higher axion masses can be restored by the addition of a buer gas inside the magnet bores. The CAST experiment has used 4 He and 3 He as buer gases in dierent periods. In order to scan a wide range of axion masses in small 38 Chapter 2. The CAST experiment Figure 2.8: Scheme of the CAST magnet vacuum. The cold windows (green) separate the buffer gas volume (red) from the general vacuum system (yellow). The cryostat vacuum (blue) provides thermal insulation from the environment. steps, precise amounts of gas has to be inserted inside the cold bores and thus an accurate gas lling system was installed. 2.2. Technical description 39 The buer gas has to be conned inside the magnetic eld region, for this purpose four cold windows were installed at the end of the magnet bores (see gure 2.8). The requirements of the cold windows are: high X-ray transmission, a low leak rate of helium from the cold bore to the vacuum side and robustness against rapid increases of the pressure (e.g. during a quench). Figure 2.9: Left: Photo of the cold window placed on the strongback. Right: Drawing of the cold window and its different parts. The cold windows are made of 14 µ m polypropylene foil glued on a stainless steel grid structure also called strongback (see gure 2.9). The cold windows was manufactured and tested by the CERN Central Cryogenics Laboratory (Cryolab). The gas system was upgraded when the 4 He was replaced by 3 He. Since the 3 He is an extremely expensive gas, additional systems were installed to prevent any leak [68]. A scheme of the lling system is shown in gure 2.10 in which the different elements are labeled: storage volume, purging system, metering volumes and expansion volume. The storage volume has a capacity of 963 l, here the gas remains below atmospheric pressure in order to preserve the gas in case of leak. The purging system is composed by two charcoal traps in order to ensure the purity of the gas. The metering volumes MV2 and MV10 have capacities of 1.63 l and 8.58 l respectively. The MV10 volume is used to ll big amounts of gas while the MV2 volume is used to insert more accurately small amounts of gas. Both metering volumes are inside a thermal bath with a constant temperature of 36.0◦ C, for a precise calculation of the amount of gas in the metering volumes. The gas is sent from the storage volume to the respective metering volume through the purging system. Later on, the gas in the metering volume is inserted inside the conversion volume of the magnet. The gas system is controlled by a PLC 5 system that allows the transfer of the gas to the dierent volumes, also is used to perform 5 Programmable Logic Controller 40 Chapter 2. The CAST experiment Figure 2.10: Scheme of the gas system. 2.3. The CAST research program 41 the recovery process. The PLC is integrated with a SCADA 6 system that provides a GUI 7 , it communicates with the pneumatic valves and pumps of the gas system. In case of quench the pressure of the conversion volume inside the magnet can rise dramatically. In order to prevent a break of the cold windows, the PLC sends a signal to open two electrovalves that connect the conversion volume to the expansion volume where the buer gas can ow. The expansion volume has a capacity of 450 l and is placed on the top of the magnet. After a quench the recovery process is started and the gas is transferred from the expansion volume to the storage volume. 2.2.5 The slow control The slow control is a centralized system designed to monitor and control the main parameters of the dierent subsystems. The CAST slow control is a Labview based data acquisition and plotting system. It communicates with multiple NI 8 data acquisition cards connected to dierent sensors of the CAST experiment. A great number of parameters are monitored such as: pressures (detectors, buer gas and vacuum systems), temperatures, magnet movement, valve status and many others. All these parameters are measured in real time and can be displayed on the program (see gure 2.11). The data is stored every minute and periodically transferred to the AFS 9 storage system. Also dierent alarms are implemented, that are triggered if some parameters are out of a given limit, in this case a SMS 10 is sent to the corresponding responsible of the system. 2.3 The CAST research program The CAST experiment started in 2003 being the most sensitive helioscope so far. The data taking at CAST was divided in two dierent phases: a Phase I with vacuum and a Phase II with a buer gas inside the magnet bores. Also two dierent periods could be distinguished during Phase II: the rst one by using 4 He as buer gas and the second with 3 He. The Phase I data taking period started in 2003 and nished in 2004. The detectors working at this time was a CCD on the focal plane of a X-ray telescope, a TPC and a Micromegas. In these conditions CAST obtained an experimental limit on the coupling constant of gaγ <8.8×10−11 GeV −1 at a 95 % of C.L. for axion masses ma<0.02 eV [69]. In order to restore the coherence to higher axion masses the magnet bores were lled with a buer gas during Phase II. From 2005 to 2006 4 He was used as buer gas, providing an experimental limit of gaγ <2.17 ×10−10 GeV −1 at 95 % of C.L. for 6 Supervisory Control and Data Acquisition 7 Graphical User Interface 8 National Instruments 9 Andrew File System 10 Short Message Service 42 Chapter 2. The CAST experiment Figure 2.11: Snapshot of the slow control program of the CAST experiment axion masses 0.02 < ma<0.39 eV [70]. Since the saturation pressure of 4 He at 1.8 ◦ K is around 17 mbar and the 4 He could liquefy, CAST did not go to higher pressures in order stay within safety limits. With the purpose of scan higher axion masses the 4 He was replaced by 3 He, in this case the saturation pressure at 1.8 ◦ K is around 135 mbar and the axion mass range could be extended up to about 1.2 eV. During 2007 the CAST gas system was upgraded and also the TPC detector was replaced by two Micromegas detectors. The 3 He phase started in 2008 and ended in 2011, scanning axion masses from 0.39 < ma<1.17 eV and obtaining an experimental limit of gaγ <2.3×10−10 GeV −1 for 0.39 < ma<0.64 eV [71] and gaγ <3.3×10−10 GeV −1 for 0.64 < ma<1.17 eV at 95 % of C.L. [72]. Crossing rst time the KSVZ line, one of the most favored theoretical models. The excluded regions in the dierent periods are represented in gure 2.12. In parallel CAST has also been looking for more exotic axions, like axions with an energy of 14.4 keV from the 57 Fe transitions [73], high energy axions from the 7 Li and D(p, γ ) 3 He nuclear decays with a gamma-ray calorimeter [74] and non-hadronic 2.3. The CAST research program 43 Figure 2.12: Axion-photon coupling limit as a function of the axion mass at the CAST experiment. Three different data taking periods are shown: Phase I (CAST Vacuum) in black, the 4He Phase II in blue and the 3He of the Phase II in red. Solar axions [75] introduced in section 1.7.1.2. Moreover during 2013 a SDD 11 was installed for more exotic particles searches [76], like chameleons. Although CAST nished its original research program in 2011, the data taking period has been extended. During 2012 the 4 He phase was revisited, improving the previous limit in a narrow mass range [77]. In 2013 CAST started a new data taking campaign revisiting the vacuum phase, motivated by the improvement of the background levels on the detectors. Also the rescanned vacuum phase continues during 2014 when a dedicated X-ray focusing device in the focal plane of a Micromegas detector has been installed and a considerable improvement of the sensitivity is expected. These features will be described in chapter 7. 11 Silicon Drift Detector 50 Chapter 2. The CAST experiment The Micromegas bulk detectors are robust and inexpensive, also it is possible to construct large areas. They have an acceptable energy resolution and a high gain. The advantages of this manufacturing technique motivate the replacement of the classical Micromegas of the Sunrise side at CAST by this novel bulk technology. However the performance of the bulk detectors is not as good as the microbulk Micromegas. Also the PCB readout is not radiopure which is not desirable for low background experiments. 2.4.3.3 Microbulk Micromegas In the microbulk Micromegas [89] the anode and the mesh are produced together during the manufacturing process (see gure 2.19 left) by the use of a double sided copper coated kapton foil (copper-kapton-copper) of about 50 µ m thick. The pattern anode readout is made by removing the copper with a photolithographic process. In addition several single side coated kapton foils may be attached for the requirements of the readout, these foils are etched and biased in concordance with the readout pattern. Finally the mesh grid is made by a photochemical process creating a hole pattern (see gure 2.19 right) and then the kapton is etched and removed in order to cpreate small pillars. Figure 2.19: Left: Scheme of the microbulk manufacturing process. Right: Microscopic view of the mesh holes pattern in a microbulk detector. Plots taken from [89]. The manufacturing process of the microbulk Micromegas detectors shows the highest homogeneity in the amplication gap. This leads on the best energy resolution reached in a Micromegas detector with a high gain. Also the materials used in the construction, mainly copper and kapton, are radiopure. The better performance of this technology motivates the replacement of the bulk Micromegas working at CAST. In contrast with bulk detectors, microbulk Micromegas are more expensive and large areas cannot be easily constructed. The Micromegas detectors are very versatile and are used in dierent experiments 2.4. X-ray detectors in the CAST experiment 51 such as T2K 17 [90], nTOF 18 [91], COMPASS 19 [92] and it is projected in many others experiments like in MAMA 20 [93] for the ATLAS detector upgrade at the LHC and MIMAC 21 [94]. These experiments include accelerator and rare event searches and dierent technologies as bulk and microbulk are used. Also CAST is the best representative experiment for Micromegas detectors in which three of the four detectors currently installed are of the microbulk type. A more detailed description of the Micromegas detectors working at CAST together with the dierent detector systems will be introduced in next chapter. 17 Tokai to Kamioka 18 neutron time-of-ight 19 Common Muon and Proton Apparatus for Structure and Spectroscopy 20 Muon Atlas Micromegas Activity 21 MIcro TPC MAtrix of Chambers Chapter 3 The Micromegas detectors in the CAST experiment Contents 3.1 Introduction ............................ 53 3.2 The Micromegas detectors .................... 53 3.2.1 Interactions of particles in gaseous detectors .......... 54 3.2.2 Working principles of Micromegas detectors .......... 59 3.3 Micromegas detectors at CAST ................. 63 3.3.1 Sunrise Micromegas system ................... 65 3.3.2 Sunset Micromegas system ................... 67 3.4 Micromegas background history at CAST. .......... 68 3.1 Introduction The Micromegas detectors at CAST have shown an extraordinary evolution in terms of background level and detector performance since the beginning of the experiment. These improvements could be explained by the development of new manufacturing techniques as it was shown in section 2.4.3.3. For a better understanding of the processes involving this kind of detectors, a briey description of the interaction of particles in gaseous detectors will be presented. Also the working principle of the Micromegas detectors will be detailed. The understanding of the processes involving the detection of axions at CAST comes through a deep knowledge of the detector systems. For this reason the main features of the dierent lines at the Sunset and Sunrise side will be described. Finally the evolution of the background levels of the Micromegas detectors in dierent data taking campaigns will be presented. 3.2 The Micromegas detectors Micromegas are gaseous ionization detectors with two dierent regions separated by a mesh: the conversion region and the amplication region. In the conversion region the interacting particles ionize the gas generating primary charges, these interactions 54 Chapter 3. The Micromegas detectors in the CAST experiment will be described in section 3.2.1. In the conversion region an electric eld is applied and the electrons are drifted to the amplication region. In this region an avalanche of the primary electrons occurs, due to the strong electric eld present in the gap, generating a readable signal. These processes which involve the signal generation in the Micromegas detectors will be detailed in section 3.2.2 3.2.1 Interactions of particles in gaseous detectors In order to detect a particle, it must interact with the detector and transfer energy in a readable manner. This energy transfer can be translated in ionization, generating electron-ion pairs (in ionizing detectors) and the excitation of the atoms of the detector. Also the deexcitation of these atoms can be performed mainly via three dierent channels that can be measured: heat (or phonons) in bolometers, light in scintillators and electron-ion pairs in ionization detectors. The Micromegas detectors are included in the gaseous ionization detectors and thus this section will focus on the related processes. 3.2.1.1 Interaction of charged particles The energy transfer of charged particles through gaseous detectors is mainly done by electromagnetic interactions in which the most dominant process is the Coulomb scattering. This process could be explained by the interaction of a charged particle in the Coulomb eld of the atoms of the detector. It yields an energy transfer from the incoming particle to the detector ionizing the gas. The energy loss of the charged particles per unit length is given by the Bethe-Bloch [95,96] equation: −dE dx =NAρZ A 4πz2e4 β2mec2ln 2mec2β2 I(1 −β2)−β2 (3.1) here NA is the Avogadro's number, Z and A are the atomic number and weight while ρ is the density of the target material; z is the charge and β the velocity relative to c of incoming particle ( v=βc ); me and e are the electron mass and charge respectively and I is the mean ionization potential in the target material. Although the Bethe-Bloch equation is valid for moderate relativistic charged heavy particles additional corrections are necessary in equation 3.1 for the density eect at high energies and shell corrections at low energies. The shape of the Bethe-Bloch equation is shown in gure 3.1. The energy loss decreases as the energy increases until a minimum followed by an almost constant value also called Fermi plateau. Thus for soft relativistic particles ( 10 ≤βγ ≤100 where γ= (1 −β2)−1/2 ) the energy loss is independent of the energy of the particle and relatively weak. This kind of particles are called minimum ionizing particles (MIPs) and generically the energy loss can be approximated to ∼ 2 MeV g −1 cm −1 . The main task in the Bethe-Bloch equation is the determination of the mean excitation energies that have to be estimated by experimental stopping powers measure- 3.2. The Micromegas detectors 55 Energy (MeV) -2 10 -1 10 1 10 2 10 3 10 4 10 ) -1 dE/dx (MeV cm 0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 e µp Figure 3.1: Bethe-Bloch parameterization of the stopping power in Ar for different particles: electrons (red), muons (blue) an photons (black). Equation 3.1 has been used for protons and muons while equation 3.2 is used for electrons. ments [97] (see gure 3.2 left). Also the energy loss is the average value of many collisions into the absorber and it is only valid for thick or dense enough materials. In the case of thin absorbers the energy loss can be described by the Landau distribution [98], in which the most probable value is lower than the one extracted from the Bethe-Block equation. However for very thin absorbers such as TPC's, the distributions are wider than the original Landau function (see gure 3.2 right). Also strong electronic collisions may transfer a big kinetic energy to single electrons, generating a secondary ionization. These electrons are known as δ -rays and its energy could be large enough to be distinguished as tracks. Moreover electron collisions have a dierent behavior than heavier particles, because in this case the collisions are between particles with similar masses and thus the Bethe-Bloch equation from 3.1 needs some modications. −dE dx =NAρZ A 4πz2e4 β2mec2ln mec2(γ−1) 2I−β2 (3.2) The energy loss of high energy electrons (above 10 MeV) is dominated by radiative interactions (see gure 3.3 top) called Bremsstrahlung. In this interaction an incoming electron is deected in the electric eld of a nucleus and a portion of the kinetic energy of the electron is converted into a photon. On the other hand the energy 56 Chapter 3. The Micromegas detectors in the CAST experiment Figure 3.2: Left: Mean excitation energies (I/Z) for different materials, plot taken from [97]. Right: Cumulative energy loss (straggling function) for particles with βγ = 3.6 in 1.2 cm of Ar (solid line), where ∆pis the most probable energy loss, h∆iis the mean energy loss from the Bethe-Bloch equation and wis the full width half maximum (FWHM) of the distribution. The dashed curve represents the original Landau function. Plot taken from [98]. loss of low energy electrons (such as δ -rays) is dominated by collisions in which the electrons are continuously deected and its trajectories are not straight, in contrast with heavy ions. In this case it is more practical the use of the range of electrons, dened as the average path length traveled for a charged particle with a given energy. A parameterization of the range of low energy electrons (up to ∼ 100 keV) can be empirically extracted: R= 0.71E1.72 (3.3) here R is the range in g cm −2 and E is the energy of the electron in MeV. Although equation 3.3 reproduces the shape of the range of the electrons, more accurate parameterizations can be found in the literature, like the CSDA 1 range from the ESTAR 2 [99] database from NIST 3 . The dierences between both parameterizations are shown on the bottom of gure 3.3. 3.2.1.2 Interaction photons In contrast with charged particles, photons can travel some considerable distance without interacting. Also the interactions of the photons lead to a partial or total energy transfer to the medium. So in this case is more appropriate the use of the interaction probability of a photon and its cross section. Which is usually parameterized by the intensity I(x) of a beam of photons of a given energy after crossing a material with a thickness x , by the expression: 1 Continuous Slowing Down Approximation 2 Stopping power and range tables for electrons 3 National Institute of Standards and Technology 3.2. The Micromegas detectors 57 Figure 3.3: Top: Stopping power of electrons in Ar. The dashed red line represents the energy loss from the electronic collisions and the red dotted line is the contribution of the radiative losses (Bremsstrahlung). The solid black line is the total stopping power. Bottom: Range (R/ρ) of electrons in Ar as a function of the energy. The black line is the parameterization from equation 3.3 while the red triangles have been extracted from the ESTAR database. I(x) = I0e−µρx (3.4) where I0 is the intensity of the beam before crossing the material, ρ is the density of the material and µ is the mass attenuation coecient in cm 2 g −1 . Also in the literature there are dierent denitions of this interaction with other interpretations related with µ , such as: the cross section σ=µρ/N (where N is the density of atoms in the material) or the mean free path λ= 1/(µρ) . 58 Chapter 3. The Micromegas detectors in the CAST experiment Figure 3.4: Mass attenuation coefficient of photons in Ar as a function of the energy of the incident photon. Three different processes are drawn: photoelectric (red dashed line), Compton (blue dotted line) and pair production (green dashed and dotted line). The solid black line corresponds to the total mass attenuation, which is the addition of the different contributions. Data taken from the XCOM [100] database. Photons can interact with matter via mainly three processes: photoelectric eect which dominates at low energies, Compton scattering that becomes signicant at mid energies and pair production at high energies (see gure 3.4). The total cross section is given by the sum of the dierent cross sections of these processes µTotal = µPhoto +µCompton +µPair In the photoelectric process a photon transfers its entire energy to a bound electron of an atom in the medium. It results in the emission of a photo-electron with the energy of the incoming photon minus the binding energy of the electron in the atom Epe =Eγ−Eshell . The total cross section is given by the sum of the dierent shells contributions in which the K-shell dominates the cross section of the process. For instance this eect can be observed in gure 3.4, it causes a sharp increase of the mass attenuation above ∼ 3 keV that correspond to the K-shell binding energy of the Argon. After the photoelectric interaction, the atom may return to its ground state via two processes: uorescence or the emission of an Auger electron . In the uorescence process the vacancy of an inner i th shell is lled with an electron from an upper j th shell with lower binding energy and a photon with and energy Ei−Ej is emitted. 3.2. The Micromegas detectors 59 On the other hand the total energy available could be released by the emission of an Auger electron, however this process is more unlikely. The uorescence processes in the detector may cause the occurrence of additional peaks in the spectra. If the photoelectric eect occurs inside the conversion region and the X-ray from the uorescence is not absorbed, the detected energy would be Eescape =Eγ−Eshell , this is the so-called escape peak . If the photoelectric eect occurs outside the conversion region, only the X-ray from the uorescence could be detected. These processes only represent a few percent of the events and are strongly dependent of the geometry of the detector, also it can be distinguished as dierent depositions of energy in a TPC detector. In general the photo-electron and the uorescence photon are absorbed at the same point in the detector and thus the total amount of energy from the photon is detected. The Compton scattering becomes dominant at higher energies than the photoelectric does. In the Compton interaction a photon is scattered in presence of an electron, transferring a part of its energy to the electron. In a rst approximation the electron can be considered free (not bounded to a nucleus) and the interaction could be parameterized by: E0 γ=Eγ 1 + (1−cos θ)Eγ mec2 (3.5) here E0 γ is the energy of the scattered photon while Eγ the energy of the original photon; mec2 is the mass of the electron and θ the dispersion angle of the scattered photon. This expression yields a maximum energy transfer ETmax from the photon to the electron for θ=π : ETmax =2E2 γ mec2+ 2Eγ (3.6) So it is not possible for a photon to transfer more energy to an electron in a single collision via Compton scattering. It causes a sharp cut-o at this energy which is commonly named Compton edge . Low energy transfers to electrons via Compton scattering are relatively common and can have an important contribution to the background at low energies. Finally in the pair production process a high energy photon can generate an elementary particle and its antiparticle in a presence of a nucleus, usually electron-positron pairs are created. Because of the required energy of the process the pair production is only possible at high energies, in principle far away from the γ 's of the natural radioactivity and thus this process will not be treated. 3.2.2 Working principles of Micromegas detectors As it was explained previously, Micromegas detectors could be divided in two different regions, the conversion region and the amplication region, separated by a 66 Chapter 3. The Micromegas detectors in the CAST experiment Manometer Mass flow controller Electro valves Figure 3.9: Left: Photo of the Sunrise Micromegas shielding. Middle: Photo of the gas panel in which the different parts are labeled. Right: Sketch of the Sunrise manipulator installed on the line during a calibration. For background runs the source is retracted and hidden inside the flange. per day, with a 55 Fe source (main peak at ∼ 6 keV). Calibrations are essential in order to apply a discrimination criterion to the background events (see chapter 4 for further details). The calibrations are performed by a pneumatic manipulator attached to the vacuum line (see gure 3.9 right). During background runs the source is hidden inside the ange, while during calibrations the manipulator moves the source to the middle of the pipe and thus the X-rays can be detected. The manipulator is controlled remotely by the DAQ 7 . Insulator Bad vacuum Good vacuum Differential window Micromegas Magnet Gate valve VT3 Bypass Pump 1 Pump 2 Figure 3.10: Scheme of the vacuum system of the Sunrise Micromegas line. 7 Data AcQuisition system 3.3. Micromegas detectors at CAST 67 The vacuum in the line is performed by a dierential pumping system. The two dierent regions are connected by a bypass (see gure 3.10). When the pump starts, the bypass has to be opened in order to ensure the integrity of the dierential window. Only is able to close the bypass when both regions reach a good vacuum level and then the dierent systems are pumped separately. Just in this case is possible to open the gate valve VT3 directly connected to the magnet vacuum. Also the pressures in the dierent volumes are monitored and a protection system is implemented. In case of failure the bypass is automatically opened to prevent the break of the dierential window, also the gate valve is closed to avoid any contamination in the magnet bores. Furthermore an X-ray focusing device has been installed in the Sunrise Micromegas line during 2014. With a new detector design and a shielding upgrade, these features will be described in chapter 7. 3.3.2 Sunset Micromegas system The related system was installed during the 2007 upgrade, when the TPC was replaced by two Micromegas detectors. The main features are the same as described for the Sunrise Micromegas line. However in this case both detectors share the same shielding, vacuum and gas system. These peculiarities will be described below. Figure 3.11: Left: Drawing of the Sunset system. Right: Lead shielding covering the two detectors. The shielding was inherited from the former TPC. A drawing of the Sunset system and a photo of the shielding are shown in gure 3.11. In the innermost part, a copper box with a thickness of 5 mm covers the two detectors. A second layer made of archaeological lead covers the copper box, it has a thickness of 50 mm on the top, bottom and on the back of the detectors, in the laterals it is only 25 mm thick and the side to the magnet is not shielded. The lead is surrounded by a cadmium sheet of 2 mm thick and polyethylene blocks in the outermost part. A new shielding design was installed during 2012, improving the background level in a factor ∼ 4.5, the advantages of the new shielding will be described in chapter 7. 68 Chapter 3. The Micromegas detectors in the CAST experiment 5 l MM1MM2 Bad vacuum pump Good vacuum pump 1 Good vacuum pump 2 VT2VT1 Bypass Differential window Good vacuum Bad vacuum Insulator Flowmeter Manometer Electrovalves Figure 3.12: Scheme of the vacuum system and gas system for Sunset Micromegas detectors. The gas system is composed by a manometer in the input and a owmeter in the output. Also a gas reservoir with a volume of 5 l is installed in the line in order to avoid big uctuations in the pressure. Both detectors are connected in series, working with the same gas. In order to perform the vacuum a dierential pumping system is implemented, it has the same characteristics explained before for the Sunrise line. However in the Sunset side the two pipes are connected and pumped at the same time. A scheme of the gas and vacuum system of the Sunset Micromegas line is shown in gure 3.12. The calibrations are performed with two pneumatic manipulators of the same type as described for the Sunrise system. However in the Sunset line the sources are closer to the detectors (see gure 3.13) and the calibrations are made one after the other. 3.4 Micromegas background history at CAST. The Micromegas detectors at CAST have experimented a background reduction of about two orders of magnitude since the beginning of the experiment. These improvements are mainly due to the better performance of the novel Micromegas 3.4. Micromegas background history at CAST. 69 Figure 3.13: Left: Photo of the Sunset Micromegas in which the calibrators are visible. Right: Photo of the sources inside the pipes when the manipulators are in the calibration position. technologies and its radiopurity, a better discrimination of X-ray like events in the analysis and dierent shielding upgrades. Figure 3.14: Micromegas background evolution in the CAST experiment. 70 Chapter 3. The Micromegas detectors in the CAST experiment The evolution of the background level of the Micromegas detectors at CAST is shown in gure 3.14. The blue dots correspond to the rst Micromegas detectors installed at CAST of the classical technology and the background reduction is due to the improvement of the discrimination algorithms. During 2007 the Micromegas detectors were shielded, also novel technologies as bulk and microbulk were introduced. These improvements result in a background reduction of a factor 4.5 represented by the green squares in gure 3.14. Finally the red triangles correspond to the shielding upgrade of the Sunset detectors during 2012, also new electronics for the readout were installed during 2013. These features together with the dierent contributions to the background will be described in chapter 7. Chapter 4 CAST Micromegas data analysis Contents 4.1 Introduction ............................ 71 4.2 Micromegas readout and electronics .............. 71 4.2.1 Sunrise acquisition and software ................ 73 4.2.2 Sunset acquisition and software ................. 73 4.3 Data analysis ............................ 75 4.3.1 Pulse shape analysis ....................... 77 4.3.2 Cluster analysis .......................... 78 4.4 Background discrimination method .............. 80 4.1 Introduction Once described the physical processes involving the signal generation in the Micromegas detectors, this chapter will focus on the signal processing. For this purpose a detailed description of the electronics implemented for the mesh and strips readout will be presented. Also the processing of the data from the DAQ to the denition of the dierent observables will be described. Finally this chapter will focus on the discrimination method developed in order to select X-ray like events in the background runs. 4.2 Micromegas readout and electronics As it was described in section 3.2.2 there are two dierent signals in the Micromegas detectors: the mesh signal, generated by the ions in the avalanche process and the strips signals, induced by the electrons in the anode readout. The mesh signal gives information of the deposited energy in the detector and also its shape is related with the distribution of the primary charges along the perpendicular direction to the readout. Also is used to generate the main trigger of the acquisition. The mesh signal is preamplied in a rst stage using a Canberra 2004 preamplier. Afterwards the signal is shaped and amplied in an ORTEC 471 NIM 1 timing ltering amplier, which allows the tuning of dierent timing parameters. The 1 Nuclear Instrumentation Module 72 Chapter 4. CAST Micromegas data analysis amplied signal is duplicated in a linear Fan In-Fan Out module, one signal is sent to a quad discriminator in order to generate the main trigger and other signal is sent to a digitizer. The digitizing of the mesh signal is performed by a VME 2 Matacq 3 [105] board, in which the signal is recorded in a 2500 ns window with a sampling rate of 1 GHz and a dynamic range of 12 bits. The strips signals give spatial resolution and energy information of the event. The strips are readed by the front end Gassiplex cards [106], that allows the processing of 96 channels each and thus four Gassiplex cards are used to read the 106 × 106 strips readout. The Gassiplex cards integrate the charge of the strips that are stored it in dierent analog memories. In order to perform the acquisition of the strips the Gassiplex are controlled by three digital inputs: track & hold , clock and clear signals (see gure 4.1). When the DAQ is triggered a delayed track & hold signal is sent to the Gassiplex and the strips charges are integrated, later on when the rst clock signal becomes low the analog memories are frozen. Conforming the 96 clocks signal arrive (one per channel) the analog values of the memories are sent through the output of the Gassiplex and multiplexed. When the clocks ends, the track & hold signal stops and a clear signal is sent in order to reset the analog memories. The input signals are controlled by a VME sequencer (CAEN V551B) and the output signals are digitized and stored in the CRAMS 4 (CAEN V550) modules. Figure 4.1: Left: Scheme of the Gassiplex input and output signals. Right: Photo of a Gassiplex card. The dierent delays in the input signals (T1 and T2 in gure 4.1 left) can be optimized in order to get the maximum peaking in the output signal. In this set-up one nds experimentally that the output is maximized when the trigger and the track & hold signal are delayed ∼ 900 ns and the delay between the track & hold and the clock is about ∼ 100 ns. 2 Versa Module Europa bus 3 MATrix for ACQuisition 4 CAEN Readout for Analog Multiplexed Signals 4.2. Micromegas readout and electronics 73 During the acquisition of an event there is a period in which the DAQ cannot record more events because is busy, this period is called dead time . A busy signal is implemented in the DAQ and the incoming triggers are rejected in this period. The dead time is given mainly by the CRAMS and is about 10 ms, limiting the acquisition rate up to 100 Hz. Although the features described before are common for Sunset and Sunrise Micromegas DAQs, there are signicant dierences between them and have to be described separately. 4.2.1 Sunrise acquisition and software In this case the interface between the computer and the VME is performed by a NI 5 VME-MXI2 controller with a GPIB 6 connection. The DAQ software controls and communicates with the dierent VME modules in order to perform the acquisition. Apart of the Matacq, sequencer and the CRAMS described above, there are additional modules like a CAEN V560 scaler to count the total number of triggers and a CAEN V262 input-output register in order to control the manipulator for the calibrators. Also several NIM modules are used to process the dierent signals. A scheme of the electronic chain is shown in gure 4.2. A Labview based software with a GUI 7 was developed in order to perform the acquisition, also dierent tools for on-line visualization were implemented (see gure 4.3). There are predened dierent types of runs such as pedestals , calibration and background . During background and calibration runs the DAQ performs a normal acquisition, the only dierence is that the source is moved to the proper position. For the pedestal runs an external trigger is generated and only the strips values are stored. These values are used to estimate the noise level in the readout, dening a pedestal value for every strip. This method will be explained in section 4.3. The data is stored in a binary le of 4 bytes array words. It starts with a le header that contains information about the run (start time, conguration, type, etc). Moreover every single event is provided with an event header and an event footer, between them, mesh and strips info is written. The events are stored in sequentially until the footer of the le which marks the end. 4.2.2 Sunset acquisition and software The main dierence with Sunrise is that in the Sunset DAQ both detectors are acquired together at the same time. The dierent mesh signals are processed separately. After the discriminator, the resulting logic signals are passed through a logic OR gate that gives the general trigger to the DAQ. Also in this case four CRAMS are used to acquire the strips from both detectors. Another dierence is 5 National instruments 6 General-Purpose Instrumentation Bus 7 Graphical User Interface 74 Chapter 4. CAST Micromegas data analysis Figure 4.2: Sunrise Micromegas electronic diagram. that a CAEN V718 bridge with and optical link is used to communicate with the computer, instead of the GPIB connection in Sunrise. A detailed scheme of the electronic chain is shown in gure 4.4. The acquisition software is a modied version of the Sunrise DAQ, which was extended in order to acquire two detectors (see gure 4.5). In the Sunset DAQ two dierent calibration types, one per detector, are dened. Also an autopilot mode is implemented in which the DAQ acquires in a predened schedule and the different run types are acquired automatically. When the detector is in autopilot, calibrations, pedestals and background runs of both detectors are written in the same binary le. It creates a more complex le, however the dierent run types and detectors are labeled and in the rst stage of the data processing the le is split and the related data are separated. Although the electronic chain and the software presented before were installed at CAST until 2012 a novel front end AFTER 8 [108] electronic for the strips readout was installed during 2013 in the Micromegas detectors at CAST, consequently the electronic chain was modied and a new DAQ software was developed. This upgrade will be described in chapter 7. 8 ASIC For TPC Electronic Readout 4.3. Data analysis 75 Figure 4.3: Snapshot of the Labview based GUI in the Sunrise DAQ. Different windows are shown: RunControlAll.vi (top left) to start and stop the acquisition, RunControlMonitor.vi (top right) to set the different parameters in the DAQ and RunEv.vi (bottom) for the on-line visualization of the events. 4.3 Data analysis In a rst stage of the analysis the information from the DAQ is processed and dierent observables are dened, the analysis software is written using standard C++ and ROOT [109] libraries. Also the gain is calculated with the information of the observables related with the deposited energy in the calibrations les. This gain factor is applied later on to the corresponding background runs. Finally a ROOT le is generated in which the dierent observables, that dene dierent parameters of the event, are stored. For the mesh signal a pulse shape analysis (PSA) is implemented, in which the pulse is dened by dierent parameters. For the strips a cluster analysis is performed after the pedestal subtraction, dening additional observables related with the strip readout. Both analysis methods will be described below. 82 Chapter 4. CAST Micromegas data analysis Figure 4.9: Normalized probability for several observables used in the analysis. The different observables have been labeled. 4.4. Background discrimination method 83 where P(x) is the probability of a given observable to have a value x and O(x) are the odds for . The ratio of the probability of an event to have dierent observables values xi is given by the multiplication of the odds: Π = Y i Oi(xi) (4.3) here Π is the multiplication of the odds of the dierent observables denoted by i . Computing the logarithm of the odds log-odds analogous to the log-likelihood, a value is obtained for every single event that gives information about how likely is the event to an X-ray. −log(Π) = −X i log(Oi(xi)) = −X i log Pi(xi) 1−Pi(xi)=−X i log(Pi(xi))+X i log(1−Pi(xi)) (4.4) -Log Odds 0 20 40 60 80 100 Counts 1 10 2 10 3 10 Figure 4.10: Distribution of the log-odds for the 5.9 keV peak (blue), 3 keV peak (green) and background events (red). The blue filled area corresponds to a software efficiency of a 75%(cut-value = 12.8) at 5.9 keV and the green area to a 50%(cut-value = 13.9) of efficiency at 3 keV. Finally the log-odds value is computed for calibration and background events. For the calibration events two dierent cumulative distributions are obtained, one for the 5.9 keV peak and another for the 3 keV escape peak. It allows to dene a cut-value 84 Chapter 4. CAST Micromegas data analysis in the log-odds distribution below which a certain number of events are accepted. For background events with energies above 4 keV the cut-value from the 5.9 keV distribution is used, while for events with energies below 4 keV the cut-value from the 3 keV distribution is applied. This discrimination method is shown in gure 4.10 in which the distribution of the X-ray events during the calibrations is peaked to the leftmost part of the gure. On the other hand the background events are uniformly distributed with a bump on the right part. It results in a rejection factor of about the 99 % of the background events. The cut-values are determined by requiring a given software eciency , dened as the number of accepted events divided by the total number of events at 3 and 5.9 keV during the calibrations. The software eciency and its implications in the analysis will be revisited in section 5.3.2. Chapter 5 Sunrise and Sunset Micromegas results for 2011 data taking campaign Contents 5.1 Introduction ............................ 85 5.2 CAST Micromegas detectors performance .......... 85 5.2.1 Gain stability ........................... 86 5.2.2 Energy resolution ......................... 86 5.2.3 Spatial resolution ......................... 88 5.3 Micromegas eciency ....................... 90 5.3.1 Quantum eciency ........................ 91 5.3.2 Software eciency ........................ 91 5.4 2011 Micromegas background and tracking results ..... 93 5.4.1 Tracking denition and data taking overview ......... 93 5.4.2 2011 Micromegas background and tracking data ....... 95 5.1 Introduction This chapter will focus on the results of the analysis of the Micromegas detectors during the 2011 data taking campaign at CAST using the background selection method presented in section 4.4. Moreover the capabilities of the background rejection have dependence with the detector performance and will be studied. Also the analysis leads to the denition of a software eciency that has to be optimized in order to maximize the sensitivity. Finally the determination of the tracking times and a study of the compatibility of the tracking and background counts will be presented. 5.2 CAST Micromegas detectors performance In this section the performance of the microbulk Micromegas detectors taking data during 2011 at CAST will be presented. Three dierent detectors were working at 86 Chapter 5. Sunrise and Sunset Micromegas results for 2011 data taking campaign this time: the M11 in the Sunrise side, the M14 in the Sunset1 side and the M9 in the Sunset2 side. The gain evolution, energy resolution and the spatial resolution of these detectors will be presented. 5.2.1 Gain stability The gain of the background runs is dened using the closest calibration and also the background discrimination is performed with the related calibration run. The stability of the gain is a good indicator of the detector performance, so it is desirable a stable gain during the data taking period. The evolution of the gain during the 2011 data taking campaign is shown in gure 5.1. The gain of the three detectors shows a good stability along time. However there are some uctuations whose eect is related with understood events: the reduction of the gain in Sunset1 on the 29 th of May is related with the decrease of the mesh voltage, while the reduction of the strips gain in Sunrise from the 6 th to the 8 th of June is due to an intervention in which the gassiplex digital inputs were modied, also the period without data in Sunrise from the 10 th to the 15 th of June corresponds to a power cut in the line. 5.2.2 Energy resolution The energy resolution of the detectors is a good indicator of the detector performance. Indeed the Sunrise detector shows the best energy resolution while the Sunset detectors have a modest resolution. A normalized spectrum for a set of calibrations in the dierent detectors is shown in gure 5.2. The energy resolution is also measured for every single calibration run. A Gaussian t is performed to the 5.9 keV peak and the FWHM (Full Width Half Maximum) is extracted, given by the dierence between the two values at which the distribution is equal to the half of it maximum value. It is related with the Gaussian distribution by the expression: FWHM (%) = 1002√2 log 2σ µ≃235σ µ (5.1) here σ is the standard deviation and µ the mean value of the Gaussian. The evolution of the FWHM during the 2011 data taking campaign is shown in gure 5.3. The energy resolution shows a good stability along time for all the detectors. However the Sunset2 detector shows a improvement of the resolution on the 1 st of May, related with an intervention in which the noise was reduced. The Sunrise detector has a very good energy resolution of about a 18 % , being one of the best detectors working at CAST. On the other hand the Sunset detectors show a poor energy resolution, which also could be translated in a worst discrimination capabilities of the background events. Due to its modest performance, the Sunset detectors were replaced for the 2012 data taking campaign. 5.2. CAST Micromegas detectors performance 87 Sunset 1 Sunset 2 Sunrise Figure 5.1: Gain as a function of time during the 2011 data taking campaign. The three Micromegas detectors are shown: Sunset1 (top left), Sunset2 (top right) and Sunrise (bottom). The blue circles correspond to the ADC value of 5.9 keV peak in the mesh during the calibrations and the red squares show the gain of the strips after the cluster analysis. 88 Chapter 5. Sunrise and Sunset Micromegas results for 2011 data taking campaign Figure 5.2: Normalized spectra for a set of calibrations. Different detectors are shown: Sunset1 on the top, Sunset2 on the middle and Sunrise in the bottom. The plots on the left show the spectra of the mesh (black bars) while the plots on the right side correspond to the spectra in the strips readout. 5.2.3 Spatial resolution The spatial resolution of the strips readout is also a good indicator of the detector performance. Some detectors show dead areas which correspond to defects in the strip readout, usually related with disconnected strips because of a problem during the manufacturing process or strips in shortcut with the mesh that have to be removed. The spatial resolution of the dierent Micromegas detectors is shown in gure 5.4, in which the cumulative distribution of the mean cluster position for a set of calibration, also called hit-map , has been computed. 5.2. CAST Micromegas detectors performance 89 Sunset 1 Sunset 2 Sunrise Figure 5.3: FWHM as a function of the time during 2011 data taking period. The three Micromegas detectors working at this time are shown: Sunset1 (top left), Sunset2 (top right) and Sunrise (bottom). The blue circles correspond to the mesh and the red squares to the strips FWHM at the 5.9 keV peak. The hit-map has a characteristic pattern that corresponds to the metallic grid cath- 90 Chapter 5. Sunrise and Sunset Micromegas results for 2011 data taking campaign Sunset 1 Sunset 2 Sunrise Figure 5.4: Hit-map distribution for a set of calibrations in the Micromegas detectors at CAST. The three different detectors are shown: Sunset1 (top left), Sunset2 (top right) and Sunrise (bottom). The black ring corresponds to the colbore area, where the axion signal is expected. Note that the z-axis is in logarithmic scale. ode of the detector also called strongback described in section 3.3. In the Sunrise detector the strongback is clearly visible, due to its high spatial resolution, however some strips in the y-axis are missing inside the coldbore area. The Sunset detectors have a poor spatial resolution and the strongback is barely visible, also some strips are missing, but outside of the coldbore area. Moreover this eect can be caused because the calibration sources are relatively closer to Sunset than in Sunrise (20 cm and 1.5 m respectively). 5.3 Micromegas eciency The detection eciency of X-rays events from the magnet bores has to be taken into account in order to discriminate an axion signal, these features will be described in chapter 6. Two dierent eciencies can be distinguished in the Micromegas detectors: the quantum eciency in which the loss of eciency inside the detector 5.3. Micromegas eciency 91 chamber and through the detector line is computed and the software eciency, introduced in section 4.4, that takes into account the eciency of the discrimination method at dierent energies. While the quantum eciency is xed, the software eciency can be optimized in order to maximize the sensitivity in axion searches. The quantum and the software eciency and its implications in the axion searches will be described below. 5.3.1 Quantum eciency The Micromegas detector eciency was measured in the PANTER facilities of the MPE 1 . These results showed a good agreement with the simulations [110,111] performed with the Geant4 [112] toolkit. In the simulations the dierent elements present in the line, described in previous chapters have been implemented: the aluminium cathode strongback with its characteristic square grid and the 4 µ m of aluminized polypropilene window with a coating of 50 nm of deposited aluminium; the detector chamber with a drift distance of 3 cm lled with an Ar+iC 4 H 10 mixture working at a pressure of 1.4 bar; the dierential window made of polypropylene with a thickness of 4 µ m and the cold window strongback with a 14 µ m of polypropylene layer. Finally the detector response was implemented by introducing the energy resolution, to do it the eciency has been convoluted with a Gaussian function [113]. The results of the simulation with the eciency loss in the dierent elements are shown in gure 5.5. Figure 5.5: Quantum efficiency of the of the Micromegas detectors in the CAST experiment. Left: Results from the Geant4 simulation with the different efficiency loss: chamber efficiency (black line), strongback cathode (green line) and differential and cold windows (blue line). Rigth: Quantum efficiency convoluted with a Gaussian function. 5.3.2 Software eciency The background selection leads to the denition of a software eciency, which take account of the calibration X-ray events that are not accepted in the analysis. Also 1 Max Planck Institute for Extraterrestial Physics, Munich 98 Chapter 5. Sunrise and Sunset Micromegas results for 2011 data taking campaign Sunset 1 Sunset 2 Sunrise Figure 5.10: Spatial distribution of the background (blue dots) and tracking (red dots) events during the 2011 data taking campaign in the Micromegas detectors. Only the events inside the coldbore area and in the RoI ([2 −7] keV) are represented. caused by the uorescence of the external particles on the copper anode readout; the 6.4 keV peak due to uorescence in the stainless steel pipe through the detector and the 3 keV peak, which correspond to the uorescence of the Argon in the detector. A more detailed study of these events will be described in chapter 7. Finally the spatial distribution of the background and tracking events in the anode readout are represented in gure 5.10. In a close look to gure 5.10 there are small regions without events. It is related with some dead strips described in section 5.2.3, the Micromegas on the Sunrise side has the larger dead area, however this region is negligible in comparison with the coldbore area. Apart of these issues background and tracking events are homogeneously distributed inside the Micromegas detectors. As shown, background and tracking data are compatible in terms of rate, spectrum and spatial distribution. However additional statistical processing of the data has been performed in order to check the compatibility of the tracking and the background. Being events with a low probability, its occurrence should follow the Poisson 5.4. 2011 Micromegas background and tracking results 99 Figure 5.11: Time binning schema used to study the statistics compatibility of tracking (red) and background (blue) data. distribution. In order to verify it, background and tracking events are divided in time bins (see gure 5.11) and the distribution of the events inside the time bins is extracted. Figure 5.12: Distribution of the number of counts using a time binning of 15 minutes. The distribution has been obtained following the schema from figure 5.11. The distribution of the background and tracking events in the time bins are shown in gure 5.12 in which a binning of 15 minutes has been used. The black line is the expected Poissonian, calculated with the mean value of the background level, the 100 Chapter 5. Sunrise and Sunset Micromegas results for 2011 data taking campaign blue dots correspond to the background and the red squares are the distribution of the tracking events with an errorbar of 1 σ . For instance tracking and background distributions seems to t properly to the expected Poissonian. Chapter 6 A limit on the Axion photon coupling Contents 6.1 Introduction ............................101 6.2 Unbinned likelihood method. ..................101 6.2.1 The likelihood function ..................... 102 6.2.2 The unbinned likelihood ..................... 103 6.3 3 He as buer gas ..........................105 6.3.1 Gas density ............................ 105 6.3.2 Eective coherence length .................... 106 6.3.3 X-rays absorption in 3 He .................... 107 6.4 Coupling limit for the 2011 Micromegas data ........108 6.4.1 Axion mass coverage ....................... 108 6.4.2 Search for axion signature .................... 109 6.4.3 Coupling limit .......................... 111 6.5 Coupling limit for the 3 He phase ................114 6.1 Introduction In order to distinguish the presence of an axion signal, the data is analyzed by using an unbinned likelihood method. In the case of absence of signal, a limit on the axion to photon coupling is extracted. All these features will be described in this chapter. Moreover the gas dynamics of the 3 He inside the magnet bores is not trivial and could aect the calculations of the axion mass and will be described. Finally the constraints on the coupling limit for the 2011 CAST Micromegas data together with the limit of the 3 He phase will be presented. 6.2 Unbinned likelihood method. In order to take in account the variations of the density inside the coldbore during the tracking, an unbinned likelihood method was developed for the statistical analysis of the data of the 3 He phase. Before the explanation of the unbinned likelihood method the likelihood function will be introduced. 102 Chapter 6. A limit on the Axion photon coupling 6.2.1 The likelihood function The likelihood function is given by the probability density function (p.d.f.) evaluated with the data y , as a function of parameters f(y;θ) . For a set of independent yi measurements, the joint p.d.f. factorizes and the likelihood function is given by: L(θ) = n Y i=1 f(yi;θ) (6.1) here L(θ) is the likelihood function, that is maximized for a given value of θ , this feature is used to perform a maximum likelihood estimator in the likelihood ts. For the CAST analysis the p.d.f is given by the Poisson distribution and thus the likelihood function can be written as: L=1 L0 n Y i=1 e−µiµni i ni!, L0= n Y i=1 e−ninni i ni! (6.2) where L0 is the normalization factor, the index i is referred to the energy bin, ni is the number of counts measured in the i bin and µi is the expected number of counts in the i bin, given by the addition of the background and signal counts, by the expression: µi=bi+si (6.3) here bi is the expected number of background counts and si is the expected number of X-rays from the axion-photon conversion. The expected signal si has a dependence on the gas density ρ , axion mass ma and coupling constant gaγ and is given by: si(gaγ, ma, ρ) = ZE+∆E E dΦa dE Pa→γεiA∆tdE =g4 aγ ZE+∆E E dnaγ dE ∆tdE (6.4) where dΦa dE is the solar axion ux, given by equation 1.31. Pa→γ is the conversion probability of the axion into a photon in a strong magnetic eld, presented in equation 1.46. εi is the detector eciency for the bin i , in the case of Micromegas detectors quantum and software eciencies have to be taken into account. A is the magnet bore area and ∆t the time exposure. The integral is performed between E and E+ ∆E , referred to the corresponding energy bin i . In the second identity of equation 6.4 the formula have been reduced, indeed the expected number of counts are proportional to g4 aγ and dnaγ dE , the expected number of signal counts per time and energy unit. Instead of use the natural likelihood, it is easier to work with the logarithm of the likelihood ln L , also called log-likelihood . Maximizing the likelihood is equivalent to maximizing the likelihood ratio λ(θ) = f(n;µi)/f(n, n) or to minimize in this case the equivalent quantity −2 ln L . According to Wilks' theorem [116], if certain general 6.2. Unbinned likelihood method. 103 conditions are satised, the minimum of −2 ln L approaches a χ2 distribution. By computing the logarithm of equation 6.2, the following expression could be derived 1 : −χ2 2= ln L= n X i=1 ni−µi+nilog µi ni (6.5) This equation is valid in order to calculate the log-likelihood with a xed density inside the magnet bores and for a given axion mass. For instance it was used for the analysis of the vacuum and the 4 He phase. However for the 3 He phase an unbinned likelihood method was developed, in order to compute the variations of the gas density inside the magnet bores during the tracking. 6.2.2 The unbinned likelihood In this case the likelihood is given by the product over the events, not the bins. The unbinned likelihood is calculated using innitesimal time bins, in the limit of zero counts contribution and one count contribution, by the expression: ln L=X k Lk(ni= 0) | {z } Zero counts cont. +X k Lk(ni= 1) | {z } One count cont. (6.6) here the index k is referred to the time bins, which are short enough to have either 0 or 1 count ( ni= 0 or ni= 1 ). Indeed, equation 6.5 can be written as: ln L=−X k;ni=0 µi | {z } Zero counts cont. +X k;ni=1 (1 −µi) + ln µi | {z } One count cont. (6.7) Using equation 6.3, the expression introduced before can be rewritten: ln L=nc−X k;ni=0 k;ni=1 bi+X k;ni=0 k;ni=1 si+X k;ni=1 ln (bi+si) (6.8) here nc is the number of tracking counts. Moreover the equation from above can be expanded applying equation 6.4: ln L=nc−X k;ni=0 k;ni=1 bi+g4 aγ ZEf Ei dnaγ dE ∆tdE+X k;ni=1 ln dbi dt ∆t+g4 aγ∆tZEi+∆E Ei dnaγ dE dE (6.9) here ∆t is the corresponding time bin and Ei and Ef are the initial an nal energy of the RoI used in the analysis ( [2 −7] keV in the Micromegas detectors). Some terms 1 Using the approach ln n!∼nln n−n 104 Chapter 6. A limit on the Axion photon coupling are not considered in the calculations, since they do not depend on the coupling constant. However in order to perform a likelihood t they have to be taken into account, because the resulting χ2 has to be compared with the number of degrees of freedom. Nevertheless this fact does not aect the calculations performed in this work and those terms have been considered as a constant value, obtaining: ln L=nc−X k;ni=0 k;ni=1 bi−g4 aγ ZEf Ei dnaγ dE ∆tdE+X k;ni=1 ln dbi dt +g4 aγ ZEi+∆E Ei dnaγ dE dE−X k;ni=1 ln ∆t (6.10) C=nc−X k;ni=0 k;ni=1 bi−X k;ni=1 ln ∆t (6.11) Note that the fourth term in equation 6.10 is the sum over the tracking counts nc . Finally the log-likelihood can be reduced to the expression: −χ2 2= ln L=−g4 aγ ZEf Ei dnaγ dE ∆tdE | {z } Expected axion events + nc X i=0 ln dbi dt +g4 aγ ZEi+∆E Ei dnaγ dE dE | {z } Counts over the background +C (6.12) here the rst term is proportional to the expected number of X-rays from the axion to photon conversion. The second term is the sum of the number of expected counts over the background for the detected tracking counts. In order to perform the analysis, the axion mass is xed and a χ2 is obtained for several coupling constant values. Finally the presence or absence of signal can be evaluated in the χ2 - g4 aγ parameter space and in the case of absence of signal a coupling limit can be derived. These features will be described in section 6.4. The method described below is explained for the case of one detector. However the analysis is made by taking into account the data in all the detectors. The contribution of the dierent detectors can be added in the log-likelihood, by the expression: Ltot =Y dLdln Ltot =X d ln Ld (6.13) here d is referred to the corresponding detector. Using this method the detectors can be treated separately until the last stage of the analysis. Each detector has dierent background levels or eciencies that can be easily computed in this way. 6.3. 3 He as buer gas 105 6.3 3 He as buer gas In this section the dynamics of the 3 He inside the coldbore will be treated. There are mainly two dierent issues concerning the buer gas: the gas density and the eective coherence length inside the magnet bores. Both of them are related with the density prole in the magnet bores during the tracking and will be introduced. On the other hand the absorption coecient of the X-rays inside the 3 He is related with the density inside the magnet bores and will be described. 6.3.1 Gas density As it was presented in section 1.7.2.2 the eective photon mass and consequently the coherence condition is determined by the density of the buer gas inside the magnet bores, given by equations 1.52 and 1.53. The gas density inside the magnet bores is calculated using the cold bore pressure, measured at the MRB side and the magnet temperature, by computing the equation of state (EoS) of the 3 He gas [72]. However during tracking the pressure changes continuously due to the variations of the hydrostatic pressure inside the magnet bores and convection eects close to the cold windows, these eects are related with the 3 He dynamics inside the magnet bores. Moreover the magnet temperature has small changes of about 15 mK due to the tilt of the magnet. Time 05h30 05h45 06h00 06h15 06h30 06h45 07h00 ) -3 Temperature (K) / Density (kg m 1.66 1.68 1.7 1.72 1.74 1.76 1.78 1.8 1.82 1.84 Pressure (mbar) 66 68 70 72 74 76 78 80 82 CB Pressure Magnet temperature Calculated density Figure 6.1: Evolution of different observables during a tracking: pressure inside the cold bore (black line), temperature of the magnet (blue line) and calculated density (red line). The data correspond to the morning tracking on the 12th of May of 2011. In order to take into account these eects, the density inside the magnet bores is 106 Chapter 6. A limit on the Axion photon coupling calculated continuously. The pressure at the center of the magnet is determined from the measured pressure and the hydrostatic pressure dierence. The density in the center is calculated from the central pressure and magnet temperature using the EoS of the 3 He. In this way, the dynamics eects of the 3 He inside the magnet bores are taken into account by using the measured pressure. The variations of the magnet temperature, pressure and the calculated density during a single tracking are represented in gure6.1. 6.3.2 Eective coherence length The axion to photon conversion probability is computed using the magnet length, (see equation 1.46). However the dynamics of the 3 He inside the magnet bores may cause a reduction of the conversion region. This problem was solved by the introduction of an eective coherence length and the axion to photon conversion can be properly parameterized. The eective coherence length was introduced in order to take account the variations of the density inside the magnet bores. The density prole is not a constant value along the cold-bore, this eect has been included in the analysis by introducing the eective coherence length, that could be dened as the region inside the magnet bores in which the density is constant. Moreover the problem is more complex when the tilting of the magnet is introduced. Since the density prole cannot be measured directly it has to be calculated by Computational Fluid Dynamics (CFD) simulations. Figure 6.2: Left: Density profile inside the magnet bores at a pressure of 83 mbar (red Line).The dashed blue lines represent the allowed region for the density while the dashed black lines mark the effective length. Right: Effective coherence length as a function of the cold bore pressure. The black dots are the result of the CFD simulations and the blue line is a linear fit. The CFD simulations take account of the geometry of the magnet including the cold windows and link volumes, together with physical phenomena such as gravity, convection and the EoS of the buer gas. A detailed study of the density prole 6.3. 3 He as buer gas 107 using the CFD simulations at dierent pressures and tilting was performed and the eective length of the magnet has been parameterized [117]. In this case the coherence criterion is that the variation of density along magnet bore is less than ∆ρ < 0.001 kg m −3 [72,118]. The density proles and thus the eective coherence length are extracted from the CFD simulation results with the magnet in a horizontal position. For this purpose several CFD simulations at dierent pressures were computed. The eective coherence length is dened as the region in which the deviations from the central density are below ∆ρ < 0.001 kg m −3 (see gure 6.2 left). Finally the results of the dierent simulations were tted to a line (see gure 6.2 right). So the eective coherence length is parameterized using the coldbore pressure, by the expression: Leff = 8.611 −0.021PCB (6.14) here Leff is the eective coherence length in meters and PCB is the cold bore pressure in mbar. The dependency of the eective length with the cold bore pressure has been included in the statistical analysis of the data. 6.3.3 X-rays absorption in 3 He The absorption coecient Γ of the X-rays in the buer gas is included in the conversion probability, given by equation 1.46. This term takes account of the X-rays from the axion to photon conversion that are absorbed in the buer gas. The absorption of X-rays in a medium is given by: I I0 =e−ΓL; Γ = µρ (6.15) here I I0 is the fraction of X-rays that are absorbed in the medium and L is the magnet length. The absorption coecient Γ is parameterized by the attenuation coecient µ and the gas density ρ . The attenuation coecients at dierent energies have been extracted from the NIST 2 X-COM database and can be parameterized by the expression: µ(E) = exp −1.5832 + 5.9195e−0.353808E+ 4.03598e−0.970557E (6.16) The agreement between the NIST X-COM data and the t is shown in gure 6.3. For the statistical analysis of the data, the absorption coecient Γ is calculated using equation 6.16 and the gas density is estimated with the method presented in section 6.3.1. 2 National Institute of Standards and Technology 114 Chapter 6. A limit on the Axion photon coupling 6.5 Coupling limit for the 3 He phase The data of the 3 He phase of the CAST experiment have been computed and a coupling limit has been extracted. These results correspond to the data taking campaigns from 2008 to 2011 which have been already published in [71] and more recently in [72]. Although the data of all the operative Micromegas detectors have been taken into account in order to obtain the limit, the data of the CCD-telescope system, from 2009 to 2011, have not been included. The results of the 3 He phase are shown in gures 6.10 and 6.11. (eV) axion m -2 10 -1 10 1 ) -1 (GeV γa g -11 10 -10 10 -9 10 SUMICO HB stars Axion models KSVZ [E/N = 0] HDM CAST Vacuum He 4He 3 -2 10 -1 10 1 Figure 6.10: Parameter space ma−gaγ excluded by the CAST experiment for the vacuum and 4He phase (black line) and the latest results of the 3He period (red line). The yellow band is the most favored region for the axion models and the green solid line corresponds to the KSVZ model (E/N = 0). Plot taken from [72]. During the 3 He phase CAST extended its previous limit towards higher axion masses, obtaining an average value on the coupling constant of: gaγ ≤2.94 ×10−10 GeV −1 for 0.37 ≤ma≤1.17 eV (6.21) On the other hand, the limit shown in gure 6.11 has a characteristic shape. The high-frequency structure is because the dierent axion masses have a dierent ex- 6.5. Coupling limit for the 3 He phase 115 (eV) axion m 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 ) -1 GeV -10 (x10 γa g 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 Figure 6.11: Coupling limit for the CAST 3He phase at a 95%of C.L., corresponding to an axion mass range of 0.37 < ma<1.17 eV (solid red line). The green line is the KSVZ benchmark model (E/N = 0). posure time, also statistical uctuations of the data may cause this behavior. The worsening of the coupling limit for higher axion masses can be explained by dierent reasons: the time exposure was reduced to the half for axions masses above 1 eV; the continuous decrease of the eective coherence length and the increase of the absorption coecient Γ with the density, also the data from the CCD-telescope for axion masses above 0.64 eV have not been not included in the analysis. CAST nished the 3 He phase extending the axion search up to ma= 1.17 eV, being the rst time that an helioscope crosses the KSVZ ( E/N = 0 ) model, one of the most favored ones. Although there was no axion signal, CAST currently is rescanning the vacuum phase with an improved sensitivity. However the goal is to scan more favored regions for axions and ALPs, this achievement cannot be reached with the existing CAST apparatus. It will require a dedicated magnet, optics and improved detectors, as it is proposed for IAXO that will be described in chapter 8. Chapter 7 Low background techniques in Micromegas detectors Contents 7.1 Introduction ............................117 7.2 Low background techniques ...................118 7.2.1 Radiopurity ............................ 118 7.2.2 Manufacturing technology .................... 118 7.2.3 Event discrimination ....................... 119 7.2.4 Shielding ............................. 119 7.3 Test benches and simulations ..................121 7.3.1 Underground measurements ................... 121 7.3.2 Surface measurements ...................... 123 7.3.3 Simulations ............................ 124 7.4 CAST Micromegas upgrades: State of art ..........126 7.4.1 Sunset Micromegas upgrade ................... 126 7.4.2 The new Sunrise Micromegas + XRT system ......... 127 7.5 Future prospects ..........................132 7.1 Introduction Low background X-ray detectors are mandatory for axion searches or more generically for rare event searches experiments. In this chapter the low background techniques developed in order to reduce the background level of the Micromegas detectors will be introduced. Moreover, the dierent set-ups for the Micromegas detectors together with the simulations, developed in order to study the dierent contributions of the background will be presented. These special set-ups were crucial in order to reduce the background level in the Micromegas detectors in the CAST experiment. Finally the dierent upgrades of the CAST Micromegas detectors and the background reduction will be described. 118 Chapter 7. Low background techniques in Micromegas detectors 7.2 Low background techniques CAST microbulk Micromegas exploit dierent strategies, developed for the background reduction: the intrinsic radiopurity of the detectors; the detector performance, which is related with the improvements on the manufacturing process; the event discrimination of the background events in which the front end electronics has an important role and nally the shielding strategy. All these techniques have been developed in the context of the TREX project, by the University of Zaragoza group [120] and will be described in this section. 7.2.1 Radiopurity The intrinsic radioactivity of the materials used in the construction of the detector may be a source of background. As it was presented in section 2.4.3.3 the microbulk Micromegas readout is made of kapton and copper, two radiopure materials. The intrinsic radiopurity of the microbulk Micromegas readout has been measured in the Canfranc Underground Laboratory (LSC) with a high purity Ge detector [121]. These results have been conrmed recently by the measurements performed by the BiPo [123] detector at the LSC. On the other hand, the materials used in the construction of the Micromegas chamber may have an impact on the background. The chamber design was presented in section 3.3, the body of the chamber is made of Plexiglas which is intrinsically radiopure. However the strongback is made of aluminum which has a non negligible contribution of 238 U and 232 Th [122]. The impact of the aluminum strongback in the background was measured at the LSC in an special set up, this contribution will be discussed in section 7.3.1. Moreover an on-going program is measuring the contribution to the background of the dierent materials in the set-up (screws, gas gaskets, connectors, electronics, etc). The thorough study of the intrinsic radiopurity of the detectors and the chamber lead to a new detector and chamber design which was installed at CAST during 2014 in the Sunrise side. The features of this set-up will be described in section 7.4.2. 7.2.2 Manufacturing technology The performance of the Micromegas detectors may have an impact on the background and consequently in the sensitivity of the detectors. Indeed, as it was presented in section 5.2, during 2011 the Sunrise detector shows clearly a better performance than the Sunset ones. And the capabilities of the Sunrise Micromegas for axion discovery were higher. It is remarkable the progressive improvement of the performance of the Micromegas detectors that is closely linked to the development of the Micromegas technology. CAST has been one of the most demanding test-bench for Micromegas detectors from the classical Micromegas until the novel microbulk technology. Also a sys- 7.2. Low background techniques 119 tematic study on the microbulk Micromegas mesh and anode readout has been performed, optimizing the dierent parts of the structure of the detectors, such as: the anode layout, the mesh pattern, the size and shape of the mesh holes and the pitch of the strips anode. This continuous improvement on the manufacturing process of the microbulk technology is reected in the latest detector design for the Sunrise Micromegas, the one with the best detector performance working at CAST, which will be presented in section 7.4.2. 7.2.3 Event discrimination The algorithms implemented in order to discriminate the X-ray like events have been improved since the beginning of the CAST experiment. The power of this discrimination is highly coupled to the quality of the readout, so improvements in the readout design or in the manufacturing process yield improvements in discrimination power. On the other hand the rejection capabilities can be improved by the upgrade of the front-end electronics and the acquisition system. For this reason the novel front-end AFTER [108] electronics was installed at CAST during 2013 for all the Micromegas detectors. The main advantage of the new electronics is that every strip pulse is digitized and stored, in contrast with the Gassiplex-based electronics in which only the integrated charge was stored. The event information of the AFTER electronics is displayed in gure 7.1. The upgrade of the front end electronics in the strips readout leads to the modication of the electronic chain of the Micromegas detectors described in chapter 3. Also a new acquisition software has been developed, based on C++ and ROOT libraries. Moreover a new software analysis has been written, in this case the pulse shape analysis has been extended to every single strip and yields the denition of more parameters related with the strips pulses. Additionally the cluster analysis has been extended to the z direction, which allows the denition of new observables: cluster size Z and sigma Z . These new parameters can be easily included in the discrimination method introduced in section 4.4. The upgrade of the front end electronics on the strips readout supposed a reduction of the background level of about a ∼ 25 % in the Micromegas detectors at CAST. 7.2.4 Shielding The shielding design of the Micromegas detectors during 2011 at CAST has been described in sections 3.3.1 and 3.3.2. The shielding was made of an innermost layer of copper 5 mm thick, 25 mm of lead shielding and a 2 mm thick cadmium sheet. After a thorough study of the dierent background sources from simulations (see section 7.3.3) and some measurements in special set-ups (see section 7.3.1 and 7.3.2), a shielding upgrade was proposed. The shielding strategy is to increase the thickness of the dierent copper and lead 120 Chapter 7. Low background techniques in Micromegas detectors Figure 7.1: Left: Pulses from a 5.9 keV calibration event digitized by the AFTER electronics. Right: The 2D view of a background event acquired with the AFTER electronics in which the two different projections XZ (left) and YZ (right) are shown. layers in the set-up. However in the CAST experiment there are space and weight constraints on the magnet movable platform. Taking into account these constraints a new shielding design was projected with 10 mm of copper and 100 mm of external lead, in contrast with the previous set-up the cadmium sheet was removed because the contribution of neutrons is negligible. Moreover the stainless steel pipe to the magnet bore has been replaced by a copper one due to the low intrinsic radioactivity of the copper and to avoid the stainless steel uorescence from 5−7 keV that is in the RoI. Also a PTFE 1 cylinder is installed inside the pipe in order to attenuate the copper uorescence. Finally an active muon veto was installed in order to distinguish events related with 1 Polytetrauoroethylene 7.3. Test benches and simulations 121 cosmic muons. Although muons that interact directly with the detector are easily rejected by the analysis, cosmic muons may provoke uorescence in the surrounding materials, which can contribute to the background. 7.3 Test benches and simulations The CAST Micromegas set-up described in sections 3.3.1 and 3.3.2 has been replicated and some measurements were performed underground at the LSC 2 and at surface level in the laboratories of the University of Zaragoza. The main purpose of these test benches is to determine the dierent contributions to the background. The measurements performed in special set-ups together with the simulations were crucial for the upgrade of the shielding in the Micromegas detectors at CAST and will be detailed. 7.3.1 Underground measurements A CAST detector replica was installed at the LSC in order to understand the origin of the background in the Micromegas detectors. The Canfranc Underground Laboratory (LSC) is situated at Canfranc (Huesca) in the Spanish Pyrenees with a depth of 2500 m.w.e. 3 , here the muon ux is reduced by a factor 104 relative to surface [124]. So in this set-up we may consider negligible the contribution of the muons to the nal background level, however there are another sources of background that have to been taken into account, in contrast with surface operation, such as: the concentration of 222 Rn is several times higher than in surface and the environmental γ and neutron ux could be considerably larger. Figure 7.2: Left: CAST Micromegas replica at the LSC, in which the different parts are inside the Faraday cage are labeled. Right: Set-up with 100 mm of external lead, in which the electronics and the dewar used to flush nitrogen are shown. Dierent measurements have been performed in the set-up at the LSC in which 2 Laboratorio Subterráneo de Canfranc 3 meter water equivalent 122 Chapter 7. Low background techniques in Micromegas detectors nitrogen is ushed to reduce the environmental 222 Rn level inside the shielding. In a rst stage the CAST Micromegas shielding (5 mm of copper and 25 mm of lead) was installed (see gure 7.2 left), obtaining a background level of ∼6×10−6 c cm −2 keV −1 s −1 , the same level reached at surface with the same set-up. Later on, the lead shielding was increased to 200 mm and 100 mm (see gure 7.2 right), these upgrades diminished the background to ∼2×10−7 c cm −2 keV −1 s −1 [125], the lowest level reached with a Micromegas detector. Moreover dierent contributions to the background have been measured at the LSC, such as the aluminum strongback and the 222 Rn (see gure 7.3). In order to see the impact of the aluminum cathode in the background, two dierent measurements were performed, one with a radiopure copper cathode and another with the aluminum strongback, obtaining a dierence of (5.2±1.2) ×10−7 c cm −2 keV −1 s −1 between them. In addition the nitrogen ux was stopped in order to see the eect of the environmental 222 Rn in our set-up , measuring a value of (3.0± 0.8) ×10−8 c cm −2 keV −1 s −1 per Bq/m 3 of air-borne 222 Rn in the surrounding atmosphere; this level has been quantied by measuring the 222 Rn concentration inside the Faraday cage with an alphaGUARD detector [127]. Figure 7.3: Background level in the LSC during 2011. An the ultra-low background level (red arrows) was interrupted due to the measurements of the aluminum cathode (blue arrow) and the 222Rn intrusion (green arrow). Plot taken from [120]. The set-up at the LSC continues taking data measuring the contributions of the nonradiopure materials (viton gaskets, brass gas connectors,...) close to the detector, which have been replaced by radiopure ones. These upgrades on the set-up lead to a low limit closer to 10−7 c cm −2 keV −1 s −1 [120]. The set-up at Canfranc is an essential test bench for the Micromegas detectors in order to measure the intrinsic radiopurity of the materials surrounding the detector. 7.3. Test benches and simulations 123 7.3.2 Surface measurements The measurements performed in the Zaragoza laboratory were a crucial key in order to verify the impact of the muons in the background. Moreover this set-up was an important test bench to develop the DAQ for the new AFTER front end electronics. The most signicant measurements performed at Zaragoza were the ones made with a replica of the shielding upgrade of Sunset Micromegas proposed for CAST that will be described in section 7.4.1. From the results obtained at the LSC, presented before, an important background reduction was expected. After the rst measurements in this set-up the background level was ∼2×10−6 c cm −2 keV −1 s −1 , one order of magnitude higher than the level measured at the LSC in the same conditions. Indeed it indicates that the muons, that are highly suppressed underground, have a contribution in surface operation. Muon scintillators Muons Figure 7.4: Left: Set-up at the Zaragoza lab, both plastic scintillators for the muon rejection are shown. Right: Time difference between the delayed Micromegas trigger and the scintillator. The black dashed lines delimit the region for the rejection of events induced by muons in the off-line analysis. The shape of the distribution is due to the drift velocity in the Micromegas detectors. In order to see the eect of the muons in the set-up, one a plastic scintillator was installed on the top and another in one side of the Micromegas shielding (see gure 7.4 left). The signal from the scintillators is sent to a quad discriminator and the time dierence between the delayed trigger from the Micromegas and the trigger from the scintillators is stored in a VME scaler CAEN V560. Computing this time dierence, events in coincidence with a muon can be easily rejected (see gure 7.4 right). After the subtraction of the events related with muons, the background level diminished to ∼1×10−6 c cm −2 keV −1 s −1 [126]. The resulting background spectrum is shown in gure 7.5, is remarkable the reduction of the 8 keV peak, from the copper uorescence. It may indicate uorescence produced by the muons or muon showers, in a region surrounding the detector. The excellent results obtained in this set-up motivate the installation of a dedicated muon veto for the Micromegas detectors at CAST. 130 Chapter 7. Low background techniques in Micromegas detectors Field shaper PTFE coating Cu strongback Cu chamber Cu raquette PTFE gasket PTFE gasket HV connectors Figure 7.10: Top: Step file of the novel Sunrise Micromegas design in which the different parts or the chamber are labeled. Bottom: Photo of the new Sunrise Micromegas detector glued on the copper raquette. The active area is on the left while the strips signals are extracted from the central connector on the right. The HV is fed by the lines situated on the right. right). In the new design the quantum eciency in the Micromegas chamber has been enhanced, because the expected region for the axion signal is minimized after being focused by the XRT. Consequently the cathode pattern has been modied, now it has a spider web design with a central hole of 8.5 mm of diameter, big enough to contain the expected axion signal. Indeed the X-rays focused by the XRT go through the 4 µ m aluminized polypropylene window avoiding the grid structure, which was responsible of a ∼ 10 % of eciency loss in previous set-ups. The new strongback together with its projection during calibrations in the Micromegas are shown in gure 7.13. The expected focusing spot region for the X-rays has been measured using an Amptek COOL-X [130] X-ray generator, placed on the other extreme of the magnet ( ∼ 14 m far away), the result of this measurements are shown in the right part of gure 7.13. Also the DAQ is equipped with the AFTER front-end electronics for the strips readout and a new acquisition software has been developed, based on C++ and 7.4. CAST Micromegas upgrades: State of art 131 Figure 7.11: Scheme of the XRT+Micromegas line in which the different parts of the line have been labeled. Figure 7.12: Left: 55Fe calibration spectrum of the Sunrise Micromegas. Right: Gain uniformity of the Sunrise Micromegas. The dead areas (in purple) show lower values than the unity (in green) and lie outside the axion-sensitive area ROOT. Although the mesh pulse is acquired with the Matacq board as the previous acquisition, the electronic chain has been modied in order to implement the standalone electronics for the strips. After the implementation of all the features described before, the background level of the Sunrise Micromegas detector drops to (0.8±0.2)×10−6 c cm −2 keV −1 s −1 , in this case only a ∼ 25 % of the background events are rejected by the muon veto. This issue could be due to the non optimum coverage of the plastic scintillator in the set-up, because of geometrical constraints in the experimental area only a plastic scintillator has been installed. The background spectra shown in gure 7.14 is dominated by 132 Chapter 7. Low background techniques in Micromegas detectors Figure 7.13: Left: Photo of the new copper strongback with the spider web design. Center: Projection of the cathode in the Micromegas detector during the calibrations. Right: Spot generated during the X-ray finger run in the Micromegas detector, the blue circle represents the central hole in the cathode with a diameter of 8.5 mm. Energy(keV) 2 4 6 8 10 12 ) -2 cm -1 s -1 Background level (keV 0 2 4 6 8 10 -6 10× VETO OFF VETO ON Figure 7.14: Background spectrum of the Sunrise Micromegas detector during the 2014 data taking campaign. The blue line corresponds to the spectrum generated before the muons subtraction while the red line is the final spectrum after the veto cut. the 8 keV copper uorescence, which can be a hint of the eect of the muons in our set-up. Nevertheless it is the best background level reached in the CAST experiment with a Micromegas detector, the rst time below the 10−6 c cm −2 keV −1 s −1 level in stable conditions. 7.5 Future prospects The new XRT + Micromegas line in the CAST experiment has set a milestone in axion research. For the rst time an X-ray focusing device has been constructed 7.5. Future prospects 133 specically designed for axion searches, in its focal plane a low background Micromegas detector has been placed, showing an excellent background level and detector performance. (eV) axion m -8 10 -7 10 -6 10 -5 10 -4 10 -3 10 -2 10 -1 10 1 10 ) -1 (GeV γa g -11 10 -10 10 -9 10 Hot DM Transparency hint Solar (CAST) Vacuum prospects HB stars KSVZ ALP CDM -8 10 -7 10 -6 10 -5 10 -4 10 -3 10 -2 10 -1 10 1 10 Figure 7.15: Prospects of the expected sensitivity of the new vacuum phase in the CAST experiment (red line), in contrast with the current CAST limit (blue line). ALP hints and theoretical limits presented in chapter 1are also drawn. CAST will nish the rescanned vacuum phase at the end of 2015 improving his previous limit, due to the reduction of the background levels of the detectors and the use of a new XRT. Lowering the coupling limit to an expected value of ∼6×10−11 GeV −1 , this number has been obtained by a realistic Monte Carlo simulation, implementing the background levels of the detectors described before and the unbinned likelihood method presented in section 6.2. The results of the simulation, together with the current CAST limit are shown in gure 7.15. Although CAST will improve its sensitivity for axions reducing the background level of the detectors, the discovery potential of CAST is limited by the size of the magnet. In order to scan a wider region on the ma−gaγ parameter space the IAXO experiment has been proposed. The design and the potential of IAXO will be detailed in next chapter, in which ultra-low background X-ray detectors are required. It will push the low background techniques to another stage opening unexplored R & D lines that will be described below. Chapter 8 The future IAXO Contents 8.1 Introduction ............................135 8.2 The IAXO proposal ........................135 8.2.1 The IAXO superconducting magnet .............. 136 8.2.2 X-ray optics for IAXO ...................... 138 8.2.3 Ultra-low background X-ray detectors for IAXO . . . . . . . 139 8.3 Physics potential ..........................141 8.3.1 Expected sensitivity for solar axions and ALPs ........ 141 8.3.2 Search for relic CDM axions in IAXO ............. 144 8.1 Introduction The CAST experiment is the most sensitive axion helioscope so far, although its main components have been "recycled" for axion physics. Beyond CAST a new helioscope with an improved sensitivity, specically built for axion and ALPs searches, has been proposed: IAXO-the International AXion Observatory. The Letter of Intent [132] for IAXO has been submitted to CERN with a positive recommendation and the Conceptual Design Review [133] has been already published. IAXO will exploit the helioscope technique with a dedicated magnet, optics and low background detectors, which will be detailed in this chapter. IAXO will have sensitivity to the axion-photon coupling of more than one order of magnitude beyond CAST, entering a large fraction of unexplored parameter space. IAXO could become a generic facility for axion research. The possibility of hosting dark matter axion detectors in IAXO is under study. The details of the physics potential of IAXO will be also described. 8.2 The IAXO proposal IAXO will enhance the helioscope technique by exploiting all the singularities of CAST presented in previous chapters, implemented into a large superconducting toroidal magnet, together with X-ray optics and low background detectors attached at the end of the magnet bores. In this section these three main elements proposed for IAXO will be described. 136 Chapter 8. The future IAXO 8.2.1 The IAXO superconducting magnet The sensitivity of CAST is currently limited by the size of the magnet, a decommissioned LHC dipole magnet, recycled for axion searches. Indeed the helioscope technique could be enhanced using a longer magnet with a bigger aperture, specifically designed for axion physics. A new toroidal magnet, inspired by the ATLAS design, has been proposed for IAXO. Equipped with eight magnet bores, with an aperture of 60 cm of diameter each and a length of 21 m. Taking advantage of the NbTi superconducting technology, that allows peak magnetic elds up to 5.4 T with an stored energy of 500 MJ at an operational current of 12.3 kA. Figure 8.1: Left: Mid plane cut of the cryostat of the proposed IAXO magnet, the different parts are labeled. Right: Magnetic field simulation of the IAXO magnet, the rectangles are the toroid’s coils while the circles represent the position of the optics. Plots taken from [132]. An optimization study [134] shows that the sensitivity of IAXO is aected considerably by the fraction of the aperture of the telescopes exposed to X-rays. So it is preferable to use thinner coils, increasing the open aperture in front of the telescopes (see gure 8.1 right), however in this conguration the average magnetic eld drops to 2.5 T. On the other hand, the design features the decoupling of the magnet system from the optical detection systems, which simplies the system integration (see gure 8.1 left). Also it allows open bores, that are centered and aligned in between the racetrack coils in accordance with the geometrical study. The inclusion of the eight warm bores will simplify the use of experimental instrumentation and the periodic maintenance of the system. The coil windings will be cooled by conduction at a temperature of 4.5 K. The conceptual design of the cryogenic system is based on a forced ow of sub-cooled liquid helium at supercritical pressure. The cold mass operating temperature is 4.5 K and its mass is approximately 130 tons. It consists of eight coils, with two double pancakes per coil, which form the toroid geometry, and a central cylinder is designed to support the magnetic force load. 8.2. The IAXO proposal 137 The IAXO detectors will be placed in a light and conned structure, such as a dome or a framed tent that will serve as the main site for the experiment. IAXO will need to track the Sun for the longest possible period in order to increase the data-taking eciency. Thus, the magnet needs to be rotated both horizontally and vertically by the largest possible angles. A vertical inclination of ±25◦ is required, while the horizontal rotation should be stretched to a full 360 ◦ that will allow IAXO to perform trackings of about 12 h. The 250 tons magnet system will be supported at the center of mass of the whole system at the cryostat central post (see gure 8.2). The vertical movement is performed by two semi-circular structures while the rotation of the disk is generated by a set of roller drives on a circular rail system. The required magnet services, providing vacuum, helium supply, current and controls, are placed on top of the disk to couple their position to the horizontal rotation of the magnet. Figure 8.2: Schematic view of the IAXO proposal. The different parts of the magnet, magnet support, and feeds are labeled. Plot taken from [132]. Although the design of the magnet is based on the experience gained on the ATLAS toroid, the IAXO magnet will deal with a peak magnetic eld of 5.4 T, which is not trivial in terms of superconductor development and training behavior of the coil. In order to validate the design a single short prototype coil, named T0, has been proposed. The assembly of the T0 prototype for IAXO is under study, waiting for the approval of CERN. 138 Chapter 8. The future IAXO 8.2.2 X-ray optics for IAXO As it was described before, the purpose of the X-ray optics is to focus the expected X- ray signal to a small spot in the detector, by projecting the signal in a tiny region, and thus increasing the signal-to-noise ratio. The performance of X-ray optics is characterized mainly by its eciency, dened as the fraction of the X-rays focused by the optics and the size of the spot in the detector. In order to archive the smallest spot a , the optics should have a short focal length f , since the spot area grows quadratically with the focal length. At the same time, the individual mirrors that compose the optic should have the highest reectivity to X-rays, which increases by decreasing the graze angle α , since f∝α−1 , the optics should have a long enough focal length. Indeed the complication of the optical design is that the eciency and the size of the spot have a complex dependence on the incident energy E and grazing angle α . There are dierent manufacturing technologies for reective optics, in the case of IAXO the segmented and slumped glass optics has been selected, it is a consolidated technology, used recently for the NuSTAR satellite mission. Also this approach facilitates the deposition of single-layer or multi-layer reective coatings, being the least expensive of the fabrication techniques. Moreover the requirements for the angular resolution of IAXO are gentle, although other optics technologies may have better resolution than slumped glass, they would not produce a signicantly smaller spot of the solar core. Figure 8.3: Left: Focal length versus spot size √a(red squares) and the throughput of the optics (blue dots) which is calculated by dividing the a quantity related with the efficiency of the optics (DAF) by √a. The optimum is found for f= 5 m. Right: Isomorphic side view of the telescope, in which the "spider-web" structure is shown. Plots taken from [132]. After a systematic study of the throughput of the optics (see gure 8.3 right), the optimal focal length for IAXO is f= 5 m with a focusing spot of about a≃0.2 cm 2 . A detailed calculation of the optimization process can be found in [135]. The IAXO optics will be composed by 123 nested layers with a W/B 4 C coating, covering the 8.2. The IAXO proposal 139 total magnet aperture of 60 cm of diameter. All the eight magnet bores will be equipped by an X-ray optics that will be mounted on a support structure with a "spider-web" design, as it is shown in the left part of gure 8.3. For instance the manufacturing process and the technology of the new X-ray optics installed at CAST during 2014 in the Sunrise side, presented in section 7.4.2, are the same that the one proposed for IAXO. Although it has a small size, it can be considered as the rst prototype of a telescope for axion research. 8.2.3 Ultra-low background X-ray detectors for IAXO The baseline technology of the low background X-ray detectors for IAXO ir the Micromegas detectors described before. The CAST microbulk detectors have achieved record levels in terms of background and they oer the best prospects to meet the requirements of IAXO. Date 12/2004 12/2009 12/2014 ) -1 s -2 cm -1 Background level (c keV -8 10 -7 10 -6 10 -5 10 -4 10 IAXO GOAL Figure 8.4: Micromegas background history since 2002. The blue dots correspond to the unshielded Micromegas with the classic technology at CAST, the green squares are the background levels after the installation of the shielding, the black triangles correspond to the shielding upgrade from 2012 to 2014 and the red dots are the levels reached at the LSC. The dashed black line marks the goal for IAXO. Although the research in low background techniques on Micromegas detectors, pre-