Mechanical Performance Based Rationalization Research on Steel-concrete Double Composite Action Hang Su a,b, Qingtian Su a,c, Chen Xu a*, Joan R. Casas b, Guandong Zhou d a Department of Bridge Engineering, Tongji University, 1239 Siping Road, Shanghai, China 200092 b School of Civil Engineering. Department of Civil and Environmental Engineering, Technical University of Catalunya, c/Jordi Girona 1-3. Campus Nord. Modulo C-1, Barcelona (Spain) 08034 c Shanghai Engineering Research Center of High Performance Composite Bridge, 901 Zhongshanbeier Road, Shanghai, China 200092 d Guangdong Communication Planning & Design Institute Group Co., LtdοΌNo.22 Xinghua Road, Guangzhou, China 510507 Abstract Casting an extra concrete bottom layer to a steel-concrete composite box girder in a hogging moment region can increase sectional stiffness and prevent steel buckling. However, a lower sectional neutral axis may not be favorable to concrete slab cracking and steel flange stress control. To this end, a double composite girder segment was proposed and investigated. Particularly, a static loading test on a large-scaled two-span continuous girder specimen with the double composite action in hogging moment region was conducted for mechanical investigation. Meanwhile, parametric analysis was carried out as well for a rational design scheme of the double composite section. The test results revealed that the load-carrying capacity of double composite section could be increased due to the contribution of extra bottom concrete layer. The transverse deformation of steel parts was favorably constraint. The parametric analysis results indicated that slab thickness
that was 15 % of steel girder height could provide most obvious contributions to the improvements of both sectional load-carrying capacity and cracking moment. Due to the additional reinforcement, the steel web thickness of double composite girder can be saved 16.7% and the steel bottom flange thickness only needs to meet the constructing requirement compared with common composite girder. Besides, the analysis also showed replacing the tub section with steel box section in the hogging moment region can reduce the stress on top flange by 24.4%. These results are an important basis for establishing a rational design scheme for the novel double composite section. Keywords: Steel-concrete composite structure; Double composite; Numerical study; Largescaled experiment; Hogging moment region Nomenclature fy: Tensile yield strength of the steel material fu: Ultimate strength of the steel material Vu: Stud shear strength Ks1, Ks2: Secant modulus corresponding to 1/3 Vu, 1/2 Vu LVDT: Linear Variable Differential Transducer D: deflection sensor S: steel-concrete interlayer slip sensor LSοΌlongitudinal stiffening rib TS: transverse stiffening rib FEM: finite element method Ec, Es: Elasticity modulus of concrete and steel πΈπΈππ β²: Reduced elasticity modulus
π΄π΄ππ: Artificial Energy πΌπΌππ: Inertia Energy πΎπΎππ: Kinetic Energy ππππ: Strain in concrete slab πΌπΌπ‘π‘, πΌπΌππ: Regulation coefficient of the descending part of the concrete dc, dt: Compressive and tensile damage factor of the concrete ft,r, fc,r: Ultimate tensile and compressive strength of the concrete πππ‘π‘,ππ, ππππ,ππ: Strain corresponding to the ultimate tensile and compressive strength of the concrete E0: Initial elasticity modulus of concrete πππ¦π¦π¦π¦: Stress at yield point πππ’π’π¦π¦: Stress at ultimate point πππ¦π¦π¦π¦: Strain at yield point πππ’π’π¦π¦: Strain at ultimate point Mi: Bending moment under different construction stages 2LS: Specimen of web with upper and lower longitudinal stiffening ribs 1LS: Specimen of web with upper longitudinal stiffening rib πππ¦π¦π‘π‘ ππ, πππ¦π¦π π ππ, ππππ ππ: Steel top flange, steel bottom flange and reinforcement stress under different construction stages ππππ ππ: Concrete top edge stress under different construction stages Ii: Sectional bending moment of inertia under different construction stages yi: Vertical distance from the sectional neutral axis to the upper fiber under different construction stages hs, hcs, hbc: Height of the steel girder, the concrete deck slab and the concrete bottom slab n: Modulus ratio of concrete to steel
Ac, As, Abc, Ar: Section area of the concrete deck slab, the steel girder, the concrete bottom slab and the reinforcement Ic, Is, Ibc: Sectional bending moment of inertia of the concrete deck slab, the steel girder and the concrete bottom slab fct: Concrete tensile strength Mcr: Bending moment corresponding to cracking stage Rcr: Cracking moment ratio between specimen with different hbc and specimen without concrete bottom slab 1 Introduction Compared with steel and prestressed concrete structures, a continuous steel-concrete composite girder has merits in concrete compression and steel tension in sagging moment regions. However, steel compression and concrete tension confronted in hogging moment regions can easily result in steel buckling and concrete cracking. In order to improve mechanical responses of hogging moment regions in steel-concrete composite girders, a number of methods have been proposed. Applying initial prestress in the concrete slab of composite girder is one of the common techniques to prevent the concrete tension in hogging moment region. Ryu[1] conducted static test on a continuous composite box-girder and revealed the inelastic behaviour of externally prestressed continuous composite box-girder bridge with prefabricated slabs. Moscoso[2] analyzed the mechanical behavior of pre-stressed steel concrete composite beams through numerical simulation and revealed its stress distribution and cracking pattern. Lu[3] optimized the pre-stress operation on the composite girder with corrugated webs for global deflection reduction and steel local buckling
prevention. Partial shear connection achieved by adopting connector with an initial lower stiffness or reducing connector number could decrease the level of composite action and make a reduction of stresses on the concrete slab. Zhuang[4] conducted push-out tests on studs wrapped with rubber sleeves and revealed an obviously lower stiffness and larger bending deformation of rubber-sleeved stud as compared with a normal stud, while the strength varied little. Su[5] conducted 15 push-out tests and analyzed the connector stiffness effect on a continuous composite girder, showing a 39% reduction of concrete slab stress in the hogging moment region. Xu[6] and He[7] respectively conducted analytical study and presented the calculation methods of rubber-sleeved stud connector and composite girder with partial shear connection. Moreover, fiber reinforced concrete has also been applied for improving the material cracking stiffening performance. Lin[8] conducted four girder tests and revealed the contribution of steel fiber reinforced concrete (SFRC) to the composite girders subjected to hogging moment. Zhu[9] investigated the cracking behavior of curved composite girder with steel fiber reinforced concrete and engineered cementitious composites (ECC) under a hogging moment. Xu[10] studied the fatigue behavior of steel fiber reinforced concrete composite girder under high cycle negative bending action and revealed the crack restrain effect of SFRC during fatigue loading. Zhang[11] replaced the normal strength concrete in composite girder with ultra-high performance concrete (UHPC) in the hogging moment regions and presented its cracking and flexural improvement. Cheng[12] investigated the flexural improvement of composite bridge decks with corrugated steel deck and ultra-high-performance concrete slab through six composite bridge deck specimens. Besides the cracking issue in a hogging moment region, out-plane deformation of the steel
bottom flange in the region is another challenging issue. Increasing steel bottom flange thickness is a normal alternative for strength and stability needs. However, a steel plate with a large thickness has lower strength and is difficult to weld, while the additional steel can markedly increase the cost. German engineers firstly proposed a double composite girder[15][16] including an additional layer of concrete to the bottom flange of a steel girder. It could prevent steel buckling, increase sectional stiffness and limiting concrete crack propagations in hogging moment regions. The pioneer application was reported in Ciervana bridge in Spain in 1978. Kim[18] proposed a railway bridge with a double composite section and investigated the behavior of the shear connection in the double composite section. In addition, Kim[19] proposed a study on a double composite bridge and analyzed the mechanical behavior of the double composite girder with high strength steel. Shim[20] conducted tests on double composite girder with high strength steel, showing the steel high strength can be better utilized due to the prevention of the local buckling. Jiang[21] proposed a study on a composite girder with the web encased in the concrete for steel buckling prevention. Xu[22] tested two continuous composite girders and studied the mechanical behavior of double composite action in hogging moment region. In addition to the cracking performance, there is another problem which is the large stress on steel top flanges in the hogging moment region of a steel tub girder. This is because the steel top flanges have much smaller section area compared with bottom flanges, while steel top flange with large thickness also has a lower quality of fabrication and welding. This paper proposes a replacement of a steel tub in a double composite section by a steel box in hogging moment region to address the large stress issue. Compared with steel tub double composite section, the proposed steel box double composite section has larger section area of steel top flange. And it can further
strengthen the sectional flexure resistance. In addition, the steel top flange can work as a formwork for concrete casting, which is favorable for construction. Though applications of double composite actions have been reported in particular bridge practices, there have been few particular design criteria in the design codes so far. The global mechanical behavior of composite girder with double composite action was concerned by some previous researches. However, large-scaled experimental study focused on its detailed mechanical behavior is rare. In this paper, an experimental study on a large scaled composite girder was conducted for detailed mechanical investigation on double composite action, and a parametric study was executed as well for rational design criteria of the additional slab thickness in a double composite section. 2 Experimental set-up 2.1 Specimen design A two-span continuous composite girder specimen with double composite action in the hogging moment region was prepared and tested. Fig. 1 shows the specimen dimensional details, which obeyed one third shrunk scale to an actual 5Γ40m continuous composite bridge. Considering the limitation of the laboratory space and loading equipment, the longitudinal dimension of the specimen and length of each span was decided based on the intercepted segment between the two reverse bending points under dead load. Fig. 1 (a) shows the two spans, with span-lengths of 13.33m and 10.85m, including a 0.19 m free extension at each end. A 4.55m long and 160mm thick extra concrete slab was cast on the steel bottom flange in the hogging moment region. A steel box section in the hogging moment region was
adopted while a steel tub section was used in the rest. The angle-bar braces were installed to strengthen lateral stiffness and stability. Fig. 1 (b) shows that the composite girder height was 731 mm and the steel girder height was 626 mm. The concrete slab and haunch underneath were respectively 105 mm and 20 mm. The width of concrete slab was 2110 mm. Fig. 1 (c) and Fig. 1 (d) respectively show the reinforcement configuration and connection details in the bottom and top side concrete slab. There were two layers of longitudinal reinforcement. The diameter of the longitudinal reinforcement is 12 mm within the region with the double composite action and 8mm in the rest of the specimen. The stud height and shank diameter were 60 mm and 13 mm, respectively. The longitudinal and transverse stud spacing in sagging moment region were 60 mm and 100 mm, while in hogging moment region were both 100mm. Fig. 2 shows the real specimen components (Fig. 2(a), Fig. 2 (c) and Fig. 2 (d)) and casting situation (Fig. 2 (b)). (a) Specimen layout
(b) Composite sections (c) Concrete bottom slab (d) Reinforcement configuration and stud arrangement Fig. 1 Description of test specimen (mm) (a) Steel girder (b) Pouring concrete (c) Shear connector of concrete bottom slab (d) Reinforcement of concrete bottom slab
transverse direction, and the cracks developed a little faster in short span than in long span. Besides, the stirrup spacing and the observed crack spacing were approximately equal to each other. Fig. 8 shows the maximum concrete crack width development. As mentioned before, since a crack may stop developing at a certain load stage, the presented crack width may correspond to a different crack at different load stage. A crack was initially detected at 55kN, whose width was 0.04mm. Many cracks over the entire range of slab width could be observed in the hogging moment region at load stage of 200kN and developed over the entire range of slab width at 300kN. And the maximum crack width among them was nearly 0.17mm when the load was around 450kN. (a) Cracking at 100kN (b) Cracking at 200kN (c) Cracking at 300kN (d) Cracking at 450kN Fig. 7 Crack pattern development in hogging moment region(mm)
0100 200 300 400 0.00 0.05 0.10 0.15 0.20 Maximum crack width (mm) Load (kN) Fig. 8 Maximum crack width observation Fig. 9 reflects the load-strain curves of concrete slab at mid support position of the specimen before 200kN. An obvious stress mutation at load step of around 60kN can be observed due to concrete cracking. 0 200 400 600 800 0 50 100 150 200 Load (kN) Strain (ΞΌΞ΅) C1-1 C1-2 C1-3 C1-4 C1-5 C1-6 C1-7 Fig. 9 Loadβstrain curves of concrete slab at mid support (see figures 4 for location of strain gauges) 3.3 Sectional strain profiles The sectional strain distributions at internal support and mid spans are shown in Fig. 10. The distributions generally matched with the plane section assumption. When the load level was beyond 500kN, the section at internal support began to yield. Meanwhile, sections at mid spans were in elastic stage when the load level was below 600kN. Table 3 lists the neutral axis position translation feature in terms of Fig. 10 (a), showing it became lower due to concrete cracking. In the case of constant bending moment and sectional bending moment of inertia, the neutral
axis position and the elasticity modulus are the main parameters affecting the concrete stress (as shown in Eq. 1). Therefore, a reduced elasticity modulus ratio πΈπΈππ β²/πΈπΈππ could be calculated according to the decreasing neutral axis position for reflecting the decreasing mechanical contribution of the concrete slab due to cracking (as shown in Table 3). Consider the concrete slab reaches the ultimate state when the reinforcement yields, the relationship between the reduced elasticity modulus ratio and the reinforcement stress is presented in Fig. 11. As the increasing of the reinforcement stress, variation trend of the reduced elasticity modulus ratio was stable at about 0.2 before the reinforcement yielding. It can be concluded that the load-carrying capacity of the concrete slab remained about 20% of the original after the full development of cracking. i st i ' == i c c i My I E ΟΞ΅ Eq. 1
0 100 200 300 400 500 600 -1600 -1200 -800 -400 0 400 800 1200 1600 Strain (ΞΌΞ΅) Height (mm) 50kN 100kN 200kN 300kN 400kN 500kN 600kN 0 100 200 300 400 500 600 700 -1200 -600 0 600 1200 1800 2400 3000 3600 Strain (ΞΌΞ΅) Height (mm) 50kN 100kN 200kN 300kN 400kN 500kN 600kN 0 100 200 300 400 500 600 700 -1000 -500 0 500 1000 1500 2000 2500 3000 Strain (ΞΌΞ΅) Height (mm) 50kN 100kN 200kN 300kN 400kN 500kN 600kN (a) Mid support (b) Mid-span of the long span (b) Mid-span of the short span Fig. 10 Sectional strain distributions Table 3 Neutral axis position (from the bottom) and corresponding reduced elasticity modulus ratio at several load steps at mid support Load level (kN) 50 100 200 300 400 Neutral axis position(mm) 382 374 317 293 271 Reduced elasticity modulus ratio 1 0.77 0.4 0.22 0.19 Neutral axis position: the distance from the bottom of the girder to the neutral axis 050 100 150 200 0.0 0.2 0.4 0.6 0.8 1.0 Reduced elasticity modulus ratio Reinforcement stress (MPa) Fig. 11 Relationship between reduced elasticity modulus ratio and reinforcement stress 3.4 Load-slip results Load-slip distribution under several load stages is presented in Fig. 12, where the positive value indicates the slip of the concrete slab from the steel girder at the side support of the long-span. It
can be inferred that there is no slip at the mid support and mid-span. The maximum slip was attained at the quarter-span position from the mid support, with a maximum value of 0.26mm at load level of 600kN. 0 2 4 6 8 10 12 14 16 18 20 22 24 -0.3 -0.2 -0.1 0.0 0.1 0.2 0.3 Slip (mm) Distance from side support (m) 55kN 100kN 160kN 200kN 250kN 300kN 400kN 500kN 600kN Side support Mid span Mid support Mid span Side support Fig. 12 Load-slip distribution 4 Numerical and analytical analysis 4.1 Numerical model It has been proved that the double composite action conduces to prevent steel buckling and increase integral rigidity. However, the additional concrete slab may also increase the dead load and lower the neutral axis height. To further study the effect of the concrete bottom slab, finite element models (FEM) were established through Abaqus for parametric analysis. Fig.13 shows the element type and mesh of each component in the model. The concrete deck slab and concrete bottom slab were discretized with solid element C3D8R, the steel girder with shell element S4R, the open diaphragm with beam element B31, and the reinforcements with truss element T3D2. The overall mesh size of the model was 50mm. Tie commend was introduced to simulate the steel-concrete interlayer interactions[5]. As shown in reference [5], the stress in the concrete slab and the steel girder tend to be constant with the increase of the shear stiffness. Especially when βtieβ commend is used in the model instead of inputting the shear stiffness, the
stress is almost unchanged compared with inputting the shear stiffness obtained by push-out tests. Therefore, the βtieβ commend was adopted to accelerate the computational efficiency while at the same time to ensure a good accuracy of the results, Embedded region was set to constrain the reinforcement with the concrete block. Besides, displacement boundary condition was applied corresponding to the supporting positions, while loading method adopted uniform load. Sensitivity analyses were carried out. In addition, the thickness of the steel plates in the tested specimen was measured and a 0.2mm deviation in the steel plates with a thickness of 5mm and 8mm was detected. This geometric imperfection of the steel plate thickness was also considered in the model. Fig. 13 Element type and mesh of the model To ensure the accuracy of the model, sensitivity analyses were carried out as shown in Table 4. The listed nine models were all well converged since π΄π΄ππ/πΌπΌππ and πΎπΎππ/πΌπΌππ were lower than 5%. It can be seen that the dilation angle, the layers of the concrete and the concrete constitutive model have little effect on the accuracy. However, the structural damage pattern changes when the mesh size of the steel girder exceeds 100mm. To divide the concrete slab into two layers and simplify the meshing work, mesh size of both concrete and steel took 50mm. The parameters for simulation were determined as the second model in Table 4. Table 4 Sensitivity analysis results
No. Dilation angle (Β°) Layers of the concrete Concrete constitutive model Mesh size(mm) π΄π΄ππ/πΌπΌππ (%) πΎπΎππ/πΌπΌππ (%) Concrete Steel 1 25 2 fib 50 50 3.3% 2.0% 2 37.5 2 fib 50 50 0.98% 0.41% 3 50 2 fib 50 50 0.5% 0.3% 4 37.5 3 fib 50 50 2.4% 0.9% 5 37.5 4 fib 50 50 2.9% 1.0% 6 37.5 2 fib 100 100 0.6% 0.2% 7 37.5 2 fib 50 100 0.6% 0.3% 8 37.5 2 fib 75 75 0.6% 0.3% 9 37.5 2 Secant Modulus 50 50 2.5% 1.1% π΄π΄ππ: Artificial Energy πΌπΌππ: Inertia Energy πΎπΎππ: Kinetic Energy 4.2 Material properties 4.2.1 Concrete Concrete damaged plasticity model[28][29] was introduced for concrete. Fig. 14 presents the uniaxial stress-strain curve determined by Eq.2~Eq.7[30]. The plastic strain inputting into Abaqus equals to the total strain minus the elastic strain, where πππ‘π‘,ππ and 0.4ππ ππ,ππ were respectively taken as the tensile and compressive elastic strain[31]. Eq. 8 defines the damage factor d proposed by Sidoroff [32].
0123456 0.0 0.5 1.0 1.5 2.0 2.5 3.0 (ft,r,Ξ΅t,r) (Οt,Ξ΅t) Stress (MPa) Strain (10 -4 ) 0123456 0 10 20 30 40 (0.5f c,r, Ξ΅) (Ο c, Ξ΅ c ) (f c,r, Ξ΅ c,r ) Stress (MPa) Strain (10 -3 ) (a) Tensile stress (b) Compressive stress Fig. 14 The stressβstrain curve of concrete (1 ) tc dE ΟΞ΅ = β Eq. 2 5 1.7 1 [1.2 0.2 ] 1 11 ( 1) t tt t xx dx xx Ο Ο Ξ± ο£±ββ † =ο£²β> β+ ο£³ Eq. 3 Where ,tr x Ξ΅ Ξ΅ = , , tr t c tr f E ΟΞ΅ = Eq. 4 (1 ) cc dE ΟΞ΅ = β Eq. 5 2 11 1 11 ( 1) c n c c c nx nx d x xx Ο Ο Ξ± ο£±β†β+  =ο£² β> β+  ο£³ Eq. 6 Where ,cr x Ξ΅ Ξ΅ = , , , cr c c cr f E ΟΞ΅ = , , ,, c cr c cr cr E nEf Ξ΅ Ξ΅ =β Eq. 7 0 d1 E Ο Ξ΅ = β Eq. 8 4.2.2 Steel Fig. 15(a) presents a trilinear stressβstrain curve used to model the material of the steel plate. Stress at yield point πππ¦π¦π¦π¦ and ultimate point πππ’π’π¦π¦ of the steel plates with different thickness took reference from the material property test. The ultimate strain πππ’π’π¦π¦ was 0.6% and yield strain πππ¦π¦π¦π¦was
derived by πππ¦π¦π¦π¦/πΈπΈπ¦π¦, where πΈπΈπ¦π¦ was 207GPa. Fig. 15(b) shows a bilinear stressβstrain model for the reinforcement. Yield stress of the reinforcement was taken as 400 MPa, with Youngβs modulus of 200 GPa. Ξ΅ us Ξ΅ ys E s Ο us Ο ys Ultimate point Yield point 0 1 2 3 4 0 100 200 300 400 Yield point Stress (MPa) Strain (10 -3 ) (a) Steel plate (b) Reinforcement Fig. 15 The stress-strain model for steel material 4.3 Validation of FEM analysis Fig. 16 and Fig. 17 compares the load-deο¬ection curves and loadβstrain curves between the analysis and the test results. They matched with each other in general. The difference was believed mainly due to the material constitution accuracy and full interlayer interaction assumption. 0 20 40 60 80 100 120 140 0 100 200 300 400 500 600 700 800 Load (kN) Deflection (mm) FEM Experiment 0 10 20 30 40 50 60 70 80 0 100 200 300 400 500 600 700 800 Load (kN) Deflection (mm) FEM Experiment (a) Long span (b) Short span Fig. 16 Comparison of loadβdeο¬ection curves at mid-spans
0500 1000 1500 2000 0 100 200 300 400 500 600 700 800 Load (kN) Strain (ΞΌΞ΅) Top edge- FEM Top edge- Test 0-500 -1000 -1500 -2000 0 100 200 300 400 500 600 700 800 Load (kN) Strain (ΞΌΞ΅) Bottom edge- FEM Bottom edge- Test Fig. 17 Comparison of loadβstrain curves of steel flange at mid support Fig. 18 shows shear stress distribution on the steel web in the FEM model. The shear stress was particularly large in the hogging moment regions. Meanwhile, the shear stress of the steel web within the range of concrete bottom slab was relatively smaller, indicating that the double composite action helped to reduce the web stress level in the hogging moment region. Fig. 18 compares the failure appearance derived from analysis and test results. It was in consistency that the shear buckling appeared on the steel web adjacent to the additional concrete bottom slab. Fig. 18 Shear stress distribution of the steel web at failure (a)FEM result (b)Test result Fig. 19 Failure mode comparison
4.5 Evaluation of the double composite section at service stage The numerical study presented above only concerned the effect of concrete bottom slab on ultimate limit capacity. The serviceability limit state had not been investigated. It was also necessary for proposing a well-established design criteria of double composite section. Therefore, the sectional cracking moment and stress level in the service state were evaluated as well in this study. 4.5.1 Uncracked state The uncracked sectional stress distribution can be evaluated by transformed section method. Moreover, the stress evaluation takes several construction stages into account, which is shown in Fig. 23. At first, the self-weight of steel and concrete bottom slab was supported by steel girder. Then, the weight of concrete deck slab was supported by steel girder with bottom concrete slab. Afterwards, the additional external dead and live loads were supported by the entire composite section. Fig. 23 Sectional strain distribution under different construction phases The steel top flange stress πππ¦π¦π‘π‘, the steel bottom flange stress πππ¦π¦π π and the concrete top edge stress ππππ can be derived by Eqs.9-11. i st i i 1, 2, 3 i i My I Ο =β= Eq. 9 Phase 3 Phase 2 st sb st M sb Phase 1 1 3 1 3 1 2 2 2 st c M M M M Msb 3 3 1 2 3
i sb i ( ) i 1, 2, 3 i si Mhy I Ο = β= Eq. 10 i c ( )3 i ic ii Myh i nI Ο = += Eq.11 The cross-section area, vertical distance from the neutral axis to the upper fiber of the steel girder and moment of inertia under different construction phases can be derived by Eqs.12-15. Fig. 24 illustrates the geometrical parameters for the calculations in Eqs.12-15. 2 bc s A AA n = + Eq. 12 2 2 1bc bc ss Ay y Ay An  = +  ο£ο£Έ Eq. 13 3 bc c s AA AA nn =++ Eq. 14 3 3 1 bc bc c c ss A y Ay y Ay A nn  = +β  ο£ο£Έ Eq. 15 Fig. 24 Definition of cross-sectional parameters of double composite section before concrete cracking Considering cracking begins when ππππ 3 reaches the concrete tensile strength fct, the bending moment corresponding to cracking stage Mcr can be derived by Eq. 16. 3 3 ct cr c f M nI hy = β + Eq. 16 c y bc A I A , C c c s bc s A , h bc s c y s y , I S I h
4.5.2 Cracked state The contribution of cracked concrete deck slab can be ignored, while the steel girder, concrete bottom slab and the reinforcements in concrete deck slab are still in elastic stage. Section parameters during this stage can be derived by Eqs.17-18, and Fig. 25 illustrates the geometrical parameters for the calculations. 4 bc sr c A AA A n =++ Eq. 17 4 4 1 bc bc ss rr c Ay y Ay Ay An  = +β  ο£ο£Έ Eq. 18 Fig. 25 Definition of cross-sectional parameters of double composite section after concrete cracking After concrete cracking, πππ¦π¦π‘π‘, πππ¦π¦π π and reinforcements stress ππππ can be derived by Eq.19-21 using linear superposition method. 412 4 24 24 st s s MM M yyy III Ο =ββ β Eq. 19 412 4 24 24 ()( )( ) sb s s s s s MM M hy hy hy III Ο =β+β+β Eq. 20 44 4 4 () rr Myy I Ο =β+ Eq. 21 y bc bc s s , I y A I A , A r yS bc s r
4.6 Case study and parameter optimization A three span (35+60+35) m continuous composite girder bridge was taken as an example to evaluate the double composite performance and rationalize the critical component dimensions. Fig. 26 and Table 5 provide the sectional details. The sectional cracking moment Mcr can be derived by substituting necessary parameters into Eq. 17. And the variation feature of Mcr indicated by Rcr with concrete bottom slab thickness was depicted in Fig. 27. Rcr is the cracking moment ratio of a double composite section to a conventional composite section. The development of it experiences increase and decrease stages with an increasing hbc. During the increasing stage, the sectional moment of inertia growth was greater than the decline of the neutral axis. When hbc reached beyond 250mm, the sectional cracking moment decreased because of an obvious downward translation of sectional neutral axis. It meant that the optimal hbc for cracking moment improvement was around 250mm. Besides, it can also be concluded that with the decrease of steel bottom flange thickness, the cracking moment improvement became obvious. Fig. 26 Definition of the example bridge (mm) Table 10 Section detail of the (35+60+35) m continuous composite girder (mm)
Steel top flange Steel bottom flange Web Reinforcements Width Thickness Width Thickness Height Thickness Diameter quantity 4100 24 3800 26 2000 20 22 138 0 100 200 300 400 500 600 700 800 1.00 1.05 1.10 1.15 1.20 1.25 Rcr hbc (mm) 16mm 20mm 24mm 28mm 32mm 36mm 40mm 44mm 48mm Fig. 27 Relationship between cracking moment ratio and concrete bottom slab thickness for different steel bottom flange thickness A FEM of continuous composite girder, which included construction process[34], was established as shown in Fig. 28. It was for extracting the bending moments during three construction or loading phases. Particularly, M1=21813kNΒ·m, M2=3630kNΒ·m, M3=26049kNΒ·m. In terms of Eq. 21-23, the steel top flange stress πππ¦π¦π‘π‘ 4, the steel bottom flange stress πππ¦π¦π π 4 and reinforcements stress ππππ 4 can be derived. And the relationship between πππ¦π¦π‘π‘ 4, πππ¦π¦π π 4, ππππ 4 and hbc is shown in Fig. 29. It can be deduced from Fig. 29 (a) and Fig. 29 (c) that the concrete bottom slab thickness has little influence on πππ¦π¦π‘π‘ 4 and πππ¦π¦π π 4, as the stress change was within 5%. However, the steel bottom flange stress decreased up to 20% with the growth of hbc, and the rapid descent stage was before hbc reached 300mm. Based on the results obtained for the cracking moment and stress state of different representative points of the cross-section in the mid support, the conclusion is that the optimal concrete bottom slab thickness is 300mm, which represents around 0.15hs. The result also coincides
with the parametric analysis. Fig. 28 Linkage FEM model 100 150 200 250 300 350 400 450 500 192 196 200 204 208 212 216 220 Ο 4 bc (MPa) h bc (mm) 40mm 36mm 32mm 28mm 24mm 20mm 16mm 100 150 200 250 300 350 400 450 500 -120 -140 -160 -180 -200 -220 -240 -260 -280 Ο 4 tc (MPa) hbc (mm) 40mm 36mm 32mm 28mm 24mm 20mm 16mm 100 150 200 250 300 350 400 450 500 100 102 104 106 108 110 112 Ο4 r (MPa) h bc (mm) 40mm 36mm 32mm 28mm 24mm 20mm 16mm (a) Steel top flange stress (b) Steel bottom flange stress (c) Reinforcements stress Fig. 29 Relationship between stress value and concrete bottom slab thickness 5 Conclusions A large scaled (1:3) two-span continuous girder specimen with double composite action in the hogging moment region was fabricated and tested. A numerical analysis was also conducted. Based on the experimental and analytical results, the following conclusions can be drawn. (1) According to the test observations, the concrete bottom slab helps to restrain lateral deformation of steel web and steel bottom flange. It can effectively improve the anti-buckling ability of the continuous girder. (2) Based on the parametric analysis, the additional concrete slab helps to increase the cracking load and ultimate strength by 12% and 4%. However, the additional gravity load can accelerate the crack development. Besides, the optimal concrete slab thickness was found around 15 % of
the height of the steel girder. The ultimate strength decreases afterwards mainly due to a continuing downward translation of the sectional neutral axis. In addition, the concrete bottom slab can also replace the function of the lower longitudinal stiffening ribs. (3) Based on the parametric analysis, the steel web thickness can be saved 16.7%, while the steel bottom flange thickness only needs to meet the constructing requirement after using the double composite action. Besides, the box section could contribute to a 24.4% and 3.2% stress decline respectively in steel top flange and concrete slab compared with tub section. (4) According to the concrete bottom slab optimization, the cracking moment was increasing to a maximum and after that decreasing with the increase of the concrete bottom slab thickness, while the steel bottom flange stress can be decreased up to 20%. Taking into account both the cracking moment and stress state at the service stage, the optimal concrete bottom slab thickness was 15% of steel girder height. This is also in agreement with the optimal thickness obtained according to conclusion 2. Due to its advantage of steel flange stress reduction and buckling prevention, the novel double composite system is particular economical for long-span continuous composite bridge which bears high stress level in the hogging moment region. Furthermore, the double composite action can be applied together with high strength steel. Since the local buckling is prevented, the high strength of the steel material can be better utilized Acknowledgement This research is sponsored by the National Natural Science Foundation of China (No. 51978501) and the China Scholarship Council (No. 202106260050). The supports are gratefully appreciated. References
[1] Ryu H K , Shim C S , Chang S P . Inelastic behaviour of externally prestressed continuous composite box-girder bridge with prefabricated slabs[J]. Journal of Constructional Steel Research, 2004, 60(7):989-1005. [2] Morsch, Inacio, B, et al. Numerical simulation of external pre-stressed steel-concrete composite beams[J]. Computers & Concrete, 2017. [3] Lu Y , Ji L . Behavior of optimized prestressed concrete composite box-girders with corrugated steel webs[J]. Steel and Composite Structures, 2018, 26(2):183-196. [4] Zhuang B, Liu Y , Yang F . Experimental and numerical study on deformation performance of Rubber-Sleeved Stud connector under cyclic load[J]. Construction and Building Materials, 2018, 192:179-193. [5] Su H , Su Q , Xu C , et al. Shear performance and dimension rationalization study on the rubber sleeved stud connector in continuous composite girder[J]. Engineering Structures, 2021, 240(OCT.30):112371. [6] Xu X , Liu Y . Analytical and numerical study of the shear stiffness of rubber-sleeved stud[J]. Journal of Constructional Steel Research, 2016, 123(aug.):68-78. [7] He J , Lin Z , Liu Y , et al. Shear stiffness of headed studs on structural behaviors of steel-concrete composite girders[J]. Steel and Composite Structures, 2020, 36(5):553-568. [8] Lin W , Yoda T , Taniguchi N . Application of SFRC in steelβconcrete composite beams subjected to hogging moment[J]. Journal of Constructional Steel Research, 2014, 101(oct.):175-183. [9] Zhu L , Wang J J , Li X , et al. Experimental and Numerical Study of Curved SFRC and ECC composite beams with Various Connectors[J]. Thin-Walled Structures, 2020,
155:106938. [10] Xu C , Xiao H , Zhang B , et al. Fatigue behavior of steel fiber reinforced concrete composite girder under high cycle negative bending action[J]. Engineering Structures, 2021, 241(3):112432. [11] Zhang Y , Cai S , Zhu Y , et al. Flexural responses of steel-UHPC composite beams under hogging moment[J]. Engineering Structures, 2020, 206(2020):1-15. [12] Cheng Z , Zhang Q , Bao Y , et al. Flexural behavior of corrugated steel-UHPC composite bridge decks[J]. Engineering Structures, 2021, 246(3):113066. [13] Mohammed A A , Manalo A C , Ferdous W , et al. Experimental and numerical evaluations on the behaviour of structures repaired using prefabricated FRP composites jacket[J]. Engineering Structures, 2020, 210. [14] Al-Qaralleh M , Toutanji H , Eljufout T . Overloading impact on the flexural behavior of RC beams strengthened with FRP composites under fatigue: Experimental study[J]. Engineering Structures, 2020, 221:111045. [15] Saul, Reiner. Bridges with Double Composite Action[J]. Structural Engineering International, 1996, 6(1):-. [16] Stroh S , Sen R . STEEL BRIDGES WITH DOUBLE-COMPOSITE ACTION: INNOVATIVE DESIGN[J]. Transportation Research Record Journal of the Transportation Research Board, 2000, 1696:299-309. [17] Martinez-Calzon, J. Strict Box Composite Bridges. A New Design of the Optimum Use of Composite Topology. Proc., 12th Annual International Bridge Conference and Exhibition, June 19β21, 1995, Pittsburgh, Pa., Engineersβ Society of Western Pennsylvania, pp.
258β264. [18] Kim H H , Shim C S . Experimental investigation of double composite twin-girder railway bridges[J]. Journal of Constructional Steel Research, 2009, 65(6):1355-1365. [19] Kim, Choong-Eon, Yun. Structural behavior of a continuous composite truss with a composite bottom chord[J]. Journal of Constructional Steel Research, 2015, 10, 1-11. [20] Shim C S , Whang J W , Chung C H , et al. Design of Double Composite Bridges using High Strength Steel[J]. Procedia Engineering, 2011, 14(12):1825-1829. [21] Jiang, Yuchen, Xiamin, et al. Experimental study and theoretical analysis of partially encased continuous composite beams[J]. Journal of Constructional Steel Research, 2016, 117, 152-160. [22] Chen Xu, Qingtian Su, Chong Wu, Kunitomo Sugiura. Experimental study on double composite action in the negative flexural region of two-span continuous composite box girder[J]. Journal of Constructional Steel Research, 2011, 67(10):1636-1648. [23] Chinese Standard GB/T 50081-2019 Standard for test methods of concrete physical and mechanical properties, China, 2019 [24] Chinese Standard GB/T 228-2002 Metallic materials- Tensile testing at ambient temperature, China, 2002 [25] Japanese Society of Steel Construction. Standard on push-out test for headed stud [S]. Japanese Society of Steel Construction, 1996. [26] Oehlers DJ, Coughlan CG. The shear stiο¬ness of stud shear connections in composite beams. Journal of Constructional Steel Research 1986; 6:273β84. [27] Oehlers DJ, Bradford MA. Elementary behaviour of composite steel & concrete