scieee AI-readable full text Open interactive document viewer

A path to more versatile code provisions for slab deflection control

Sanabra Loewe, Marc,Capellà Llovera, Joaquim,Ramírez Anaya, Sandra,Pujadas Gispert, Ester

Abstract

An assessment of the methods of codes ACI-318 and Eurocode 2 is performed to establish a minimum slenderness for reinforced concrete slabs, which is a simplified method for controlling the deflection of slabs. This assessment is performed by comparing these methods between themselves and with two other methods that have inspired, among others, the Australian Standard for Concrete Structures. The evaluated variables include those that most influence deflection control (span, load, and allowable deflection). The study cases include spans that range from 6 m (20 ft.) to 12 m (40 ft.) and loads that range from 5 kN/m2 (104 lb/ft2) to 15 kN/m2(313 lb/ft2). The results of the study reveal some of the key advantages and shortcomings of the ACI-318 and Eurocode 2 provisions. Suggestions are given to improve the current provisions of the codes. Methods that are not too complicated but more refined can help code provisions become more versatile. This work aims to minimize potential problems caused by designing excessively thick slabs (heavy and pollutant) or excessively slender slabs (too deformable).

Full text

A path to more versatile code provisions for slab deflection control Marc Sanabra-Loewe PhD Lecturer, Department of Architectural Technology, Polytechnic University of Catalonia (Barcelona Tech), Barcelona, Spain (Orcid:0000-0002-7920-2427) (corresponding author: [email protected]) Joaquín Capellà-Llovera PhD Tenured Lecturer, Department of Architectural Technology, Polytechnic University of Catalonia (Barcelona Tech), Barcelona, Spain Sandra Ramírez-Anaya MSc Architect, BIS Structures, Barcelona, Spain Ester Pujadas-Gispert PhD Post-doctoral researcher, Innovative Structural Design (ISD), Eindhoven University of Technology, Eindhoven, The Netherlands (Orcid:0000-0002-3882-5863) An assessment of the methods of codes ACI 318 and Eurocode 2 is performed to establish a minimum slenderness for reinforced concrete slabs, which is a simplified method for controlling the deflection of slabs. This assessment is performed by comparing these methods with each other and with two further methods that have inspired, among others, the Australian standard for concrete structures. The variables evaluated include those that most influence deflection control (span, load and allowable deflection). The study cases include spans that range from 6 m (20 ft) to 12 m (40 ft) and loads that range from 5 kN/m 2 (104 lb/ft 2 ) to 15 kN/m 2 (313 lb/ft 2 ). The results of the study reveal some of the key advantages and shortcomings of the ACI 318 and Eurocode 2 provisions. Suggestions are provided to improve the current provisions of the codes. Methods that are not too complicated but more refined can help the code provisions to become more versatile. The aim of this work is to minimise potential problems caused by designing excessively thick slabs (heavy and pollutant) or excessively slender slabs (too deformable). Notation bbreadth of the rectangular section ddead load E c elastic modulus of concrete f ck characteristic cylinder compressive strength (MPa) f r modulus of rupture hdepth of slab I e effective moment of inertia Kboundary condition factor k AR ,k DP ,k SS coefficients applying to two-way slabs L,lspan L/h span/depth ratio l/dspan/effective depth ratio l n net span l n /hnet span/depth ratio M* factored moment M a largest moment in the load history M cr cracking moment M k characteristic moment W l(var) variable portion of the live load W s sustained load αstiffness coefficient α m modified stiffness coefficient α 0 initial stiffness coefficient β ES ratio applying to two-way slabs γ c partial factor for concrete γ s partial factor for steel Δ inc incremental deflection (Δ inc /l) allow allowable incremental deflection ratio κboundary condition coefficient λmultiplier for long-term deflections under sustained loads ρreinforcement ratio ρ 0 reference reinforcement ratio (one-way) 1. Introduction In recent decades, several authors have questioned the advantages of the simplified deflection-control methods that are currently provided in some codes for the design of reinforced concrete members (Beal, 2009; Bondy, 2005; Eren and Dancygier, 2020; Pecic ´and Marinkovic ´, 2011; Scanlon and Lee, 2006; Vollum, 2009). Some of these authors have stated that simplified deflection-control methods, such as the ACI 318 method, lack transparency and scarcely define the ranges for proper application. Others have pointed out several shortcomings of Eurocode 2. Besides, some of the authors of the current provisions of Eurocode 2 have proposed a way to increase the flexibility and transparency of its provisions (Pérez et al., 2017; Pérez and Corres, 2014). In parallel, a new approach to the problem has been pioneered by the Australian codes (SA, 2001), which is based on deflection-control methods that are similar to the methods discussed in this study: methods that are independent of the reinforcement ratio of a slab. 1.1 Motivation for this study When designing a reinforced concrete member under flexure, establishing an initial geometry of the cross-section of the member is usually required in the early stages of design; this is 1 Cite this article Sanabra-Loewe M, Capellà-Llovera J, Ramírez-Anaya S and Pujadas-Gispert E A path to more versatile code provisions for slab deflection control. Proceedings of the Institution of Civil Engineers –Structures and Buildings, https://doi.org/10.1680/jstbu.20.00205 Structures and Buildings Research Article Paper 2000205 Received 17/08/2020; Accepted 11/01/2021 ICE Publishing: All rights reserved Keywords: codes of practice & standards/design methods & aids/ slabs & plates Downloaded by [ Kirsten Buchanan] on [21/03/22]. Copyright © ICE Publishing, all rights reserved. different from what happens when designing a steel member or a timber member under flexure. This difference is due to the fact that reinforced concrete is a composite material that cracks under the tension caused by flexure and its design is not as linear as that of a steel member or a timber member. In the case of concrete, the required amount of steel reinforcement can only be determined based on a pre-established geometry of the concrete cross-section. In addition, deflections can only be calculated when the amount of steel reinforcement is known. Thus, deflection calculations are typically performed at the end of the design process. However, deflection checks typically govern the design of most reinforced concrete members under flexure. Given the importance of deflections, they should be considered from the earliest design stages even if they cannot be actually calculated at that time, as the amount reinforcement of the member is an unknown. This paradox is solved by establishing an initial geometry of the cross-section of the member that implicitly considers allowable deflection requirements. For this reason, picking a correct initial geometry for the cross-section can be considered a deflection-control method. The selection of an initial geometry in the early stages of the design of a slab is currently achieved by establishing its depth (h). Expressing the depth (h) as a function of span (L) by the concept of slenderness of the slab (L/h) is a common approach. The codes ACI 318 (ACI, 2014) and Eurocode 2, EN 1992-1-1 (CEN, 2004) currently have provisions to establish a minimum slenderness of the slab and state that following these provisions may be sufficient to guarantee that the required deflection limits of the same codes are satisfied. This approach of codes is very helpful because it allows a designer to establish the depth of a slab in the early stages of design and solve the previously mentioned paradox. However, in some cases in current practice, these provisions of codes may cause inappropriate use, which may happen when designers disregard the results of detailed deflection calculations in the case where they contradict the depths given by the minimum slenderness provisions provided in the codes. For example, in countries such as Spain, some insurance companies ask designers to use the minimum slenderness provisions of Eurocode 2, even if thinner slabs that satisfy the deflection limits allowed by the code can be employed. Selecting slabs that are thicker than those strictly necessary means that floors are more expensive, heavier and more polluting than strictly necessary; which may, in turn, cause unnecessarily large, expensive and pollutant-generating foundations. The opposite situation may also occur, such as designing excessively slender and deformable slabs, as Bondy (2005) demonstrated when following minimum slenderness provisions for slabs, as established in the ACI 318 code. 2. Design of the study To assess the performance of the simplified deflection-control methods for one-way and two-way slabs, as outlined in ACI 318 (ACI, 2014) and in Eurocode 2 (CEN, 2004), this study compares these methods to two other methods that are based on analytical simplified computation of deflections. The latter methods are based on research initiated by Andrew Scanlon in the early 1980s (Scanlon and Murray, 1982). In contrast, the deflection-control method, which is referred to in this study as the ‘long Rangan–Scanlon method’,was proposed by Scanlon in 1999 (Scanlon and Choi, 1999) based on previous studies by Rangan (1982) and Gilbert (1985). Furthermore, a method developed by Scanlon and Lee (2006) is referred to in the present study as the ‘short method of Rangan–Scanlon’. 3. Description of the deflection-control methods studied 3.1 Method of ACI 318 The ACI 318 method (ACI, 2014) was developed by the American Concrete Institute (ACI) in the mid-1900s and has not undergone many changes since that time. This method is primarily based on experience (ACI, 2014; Bondy, 2005). The method proposes to determine the depth (h) of a member based on a simple constant ratio: 1:L=h¼nor Ln=h¼nðÞ where ntakes different values depending on the boundary conditions, the type of structural member, the density of concrete and the strength of steel. This method and similar methods will be termed ‘constant slenderness methods’(CS methods) in this study. In the code, one-way slabs and two-way slabs are treated separately. For one-way slabs, the code provisions are given in section 7.3 and table 7.3.1.1, only for those slabs that are ‘not supporting or attached to partitions or other construction likely to be damaged by large deflections’(ACI, 2014: p. 83). These slabs are referred to in this study as slabs that are ‘not supporting non-structural damageable elements’. For two-way slabs, provisions are given in section 8.3 and table 8.3.1.1, both for slabs that may and for slabs that may not ‘support or be attached to non-structural elements likely to be damaged by large deflections’(ACI, 2014). According to the ACI 318 provisions, the slenderness of slabs thus obtained serves as an alternative method to control deflections as opposed to the detailed calculations of deflections. By way of detailed deflection computation examples, 2 Structures and Buildings A path to more versatile code provisions for slab deflection control Sanabra-Loewe, Capellà-Llovera, Ramírez-Anaya and Pujadas-Gispert Downloaded by [ Kirsten Buchanan] on [21/03/22]. Copyright © ICE Publishing, all rights reserved. Bondy (2005) showed that the L/hratios offered by the ACI may produce excessive slenderness of slabs, which do not conform to the ACI allowable deflection requirements. Thus, although this ‘CS’method has the advantage of being simple and has been validated by extensive experience with reasonably good results, it is not applicable in all cases. This situation may be linked to the fact that the results of this simplified deflection-control method do not consider the influence of several factors that do have a significant influence on deflection (refer to Table 1). 3.2 Methods of Eurocode 2 (CEN, 2004) In section 7.4.2 of Eurocode 2 (CEN, 2004), which is referred to as ‘Cases where calculations may be omitted’, provisions are established to control deflections and avoid actual deflection computations. In this study, these provisions are regarded as two distinct methods, even if the code presents them as one sole consistent method. On the one hand, the main method of Eurocode 2, is classified as a ‘reinforcement-dependent slenderness method’(RDS) in this study. On the other hand, there is a‘CS method’, which is similar to that of ACI 318. The Eurocode 2 presents this latter method only as a design aid of the main method. The Eurocode 2 main method, which is based on Corres and others (Corres et al., 2003), is designed to control deflection by establishing the slenderness of members and considers a larger number of factors than the ACI method (refer to Table 1). Thus, a better degree of accuracy in the results is expected. The formula to calculate the slenderness (l/d) for members with low reinforcement ratios, such as slabs, is described in section 7.4.2 of the Eurocode 2, where it is numbered 7.16.a, but numbered as Equation 2 here. 2: l d¼K11 þ1:5ffiffiffiffiffiffiffi fck pρ0 ρþ3:2ffiffiffiffiffiffiffi fck pρ0 ρ1  3=2 "# if ρρ0 with ρ0¼ffiffiffiffiffiffiffi fck p103 where l/dis the span/effective depth ratio; Kis the boundary condition factor (refer to table 7.4N for details) (CEN, 2004); ρ 0 (defined above) is the reference reinforcement ratio (oneway); ρis the one-way required tension reinforcement ratio at mid-span to withstand service loads; and f ck is the characteristic cylinder compressive strength (MPa). The method appears to be simple: use the closed-form Equation 2. However, this method requires previous knowledge of the actual steel reinforcement ratio of the member, which is typically unknown in the early stages of design, when depth is also an unknown. Therefore, the iterative nature of the calculation for reinforced concrete, as previously mentioned, cannot be solved unless the code has provided reference values for reinforcement ratios. The only reference to reinforcement ratio that has been found by the authors is included in the Spanish code EHE (CPH, 2008), which is consistent with Eurocode 2. The EHE code does not explicitly suggest reinforcement ratios that should be applied in Equation 2, but suggests that the reinforcement ratio ρ= 0.50% can be used for slabs when using table 50.2.2.1 of EHE, which is said to be consistent with the results of Equation 2 of the Eurocode 2. This study tests the Table 1. Factors that influence the establishment of the depth of slabs in the early stages of design that are considered in several deflection-control methods Factors ACI (2014) CEN (2004) a ‘Short method of Rangan–Scanlon’(2006) ‘Long method of Rangan–Scanlon’(1999–2014) Span Yes Yes Yes Yes Boundary conditions Yes Yes Yes Yes Total loads —Indirectly Yes Yes Sustained loads —Indirectly Yes Yes Load history —Indirectly Indirectly Indirectly Allowable deflection —— Yes Yes Yield strength of steel Indirectly Yes Indirectly Yes Required amount of reinf. (M+) —Yes Indirectly Yes Actual amount of reinf. (M+) —Yes —— Required amount of reinf. (M−)—Only cantilevers Indirectly Yes Actual amount of reinf. (M−)—Only cantilevers —— Density of concrete Indirectly —Yes Yes Elastic modulus of concrete Indirectly Indirectly Yes Yes Concrete compressive strength —Yes Indirectly Yes Tensile strength of concrete —— Indirectly Yes Moment redistribution —— — — Safety introduction method —— Indirectly Yes a The support document Corres et al. (2003) is considered to obtain the column of data for Eurocode 2 3 Structures and Buildings A path to more versatile code provisions for slab deflection control Sanabra-Loewe, Capellà-Llovera, Ramírez-Anaya and Pujadas-Gispert Downloaded by [ Kirsten Buchanan] on [21/03/22]. Copyright © ICE Publishing, all rights reserved. reinforcement ratio ρ= 0.50% as a possible constant ratio to avoid iterative computations when using Equation 2. In addition to this main method of Eurocode 2, a second method exists: the ‘CS method’described in table 7.4.N of the code. In general terms, this method is similar to that of the ACI code but the slenderness values obtained when using each method differ in most cases. The Eurocode 2 presents this second method as a design aid for the main method. However, the present study could not find consistency between the two methods. Thus, they were analysed separately. It must be pointed out that some of the main authors of the current provisions of Eurocode 2 have proposed an evolved version (Pérez et al., 2017) of the formulas currently included in Eurocode 2 that can certainly increase the consistency between the formula and the table. The evolved formula is designed to include a larger number of factors influencing deflection control, including several of the factors that this study considers. Therefore, there is currently an interest in optimising the deflection control provisions and thereby improving future codes and structures. 3.3 ‘Short method of Rangan–Scanlon’(1999–2006) This method considers an extensive range of factors that influence deflection computation (refer to Table 1). The ‘short method of Rangan–Scanlon’is classified in this study as a ‘reinforcement-independent slenderness method’, which is also termed the RIS method. The independence of the amount of reinforcement is a relevant advantage of this method, given that the reinforcement ratio is unknown in the early stages of design. One of Scanlon’s last works on this subject (Scanlon and Lee, 2006) describes the method as derived from an earlier work of Rangan (1982). Among its primary advantages is the rationality of the method. The slenderness of slabs is obtained by using a formula derived from classical formulas of deflection of one-way members. The method focuses on computing incremental deflection, which is considered to be the governing factor in the design of slabs: 3:Δinc ¼κl4 384EcIe λWsþWl varðÞ  where Δ inc is the incremental deflection; κis the boundary condition coefficient (= 5 for simply supported, = 1,4 for continuous members, = 2 for one continuous end, and = 48 for cantilevers); lis the span; E c is the elastic modulus of concrete; I e is the effective moment of inertia (after Branson); λis the multiplier for long-term deflections under sustained loads; W s is the sustained load; and W l(var) is the variable portion of the live load. Scanlon’s proposal in 2006 (Scanlon and Lee, 2006) is a generalisation, for a variety of one- and two-way floors, of a method that he developed in 1999 (Scanlon and Choi, 1999) for oneway slabs (described as the ‘long method of Rangan– Scanlon’). To transform the original one-way formulation of 1999 into the more general two-way formula of 2006, Scanlon incorporated the crossing beam method (ACI, 1995; Scanlon and Murray, 1982) and works by Timoshenko (Timoshenko and Woinowsky-Krieger, 1959), Branson (1963), Rangan (1982) and Gilbert (1985). Equation 4 is obtained by transforming I e of Equation 3 into αI b (=αbh 3 /12), dividing Equation 3 by land setting the righthand side of the resulting equation as equal to (Δ inc /l) allow . Finally, l 3 /h 3 is isolated, and both sides of the equation are cube-rooted. 4:ln h¼βES fgΔinc l  allow 32αEcb κλWSþWL varðÞ  kDP fg kARkSS fg "# 1=3 where Δ inc ,l,E c ,I e ,λ,W s and W l(var) have the same meaning defined for Equation 3; l n /his the net span/depth ratio; (Δ inc /l) allow is the allowable incremental deflection divided by the span; αis the stiffness coefficient (typically between 0 and 1); and bis the breadth of the rectangular section. The ratio {β ES } and the coefficients enclosed in curly braces {k AR ,k DP ,k SS } apply only to two-way slabs as they convert an equation for one-way deflection into an equation that considers two-way deflection (refer to section A1.4.2 of the Appendix and Scanlon and Lee (2006) for more detail). According to Scanlon, αcan be taken as a constant, which is one of his major contributions to Rangan’s formulations. Scanlon proposed a value of 0.4 in 1999 (Scanlon and Choi, 1999) and later proposed a value of 0.52 in 2006 (Scanlon and Lee, 2006) based on a new parametric study. The latter value is used in the present study, since it is the value recommended by Scanlon in his latest study. For simplicity, given the extensive experience of Scanlon in this field, in the present study, the values of all coefficients of Equations 3 and 4 are considered adequate (more details provided in A1.4 of the Appendix). Despite its advantages, this method has a disadvantage: it requires iteration because the weight of the slab (which is a part of the sustained load W s ) influences the determination of depth. However, iterations typically converge very quickly. For example, when the depth obtained by the CS method of ACI 4 Structures and Buildings A path to more versatile code provisions for slab deflection control Sanabra-Loewe, Capellà-Llovera, Ramírez-Anaya and Pujadas-Gispert Downloaded by [ Kirsten Buchanan] on [21/03/22]. Copyright © ICE Publishing, all rights reserved. 318 is considered for the first iteration, more than three iterations in total are rarely necessary (Scanlon and Lee, 2006). 3.4 ‘Long method of Rangan–Scanlon’ In this study the ‘long method of Rangan–Scanlon’refers to a method that was developed by Scanlon earlier than the ‘short method’, as described in the previous section. This method can either be used for the same purpose as the methods mentioned above (as is done throughout this study), or as a method complementary to the ‘short method’in order to improve it and prepare it to be fully operational, as clarified next. Scanlon investigated the value of the coefficient αin detail in his 1999 paper (Scanlon and Choi, 1999), in which he performed an extensive parametric study. This study did not consider αas a constant but instead included the calculation of the effective moment of inertia (I e ) in the iteration process. Subsequently, the value of αwas calculated based on I e :α=I e /I g . As a result of the systematic use of this ‘long method’, in 2006 Scanlon (Scanlon and Lee, 2006) proposed the use of a constant value of αand developed what in this study is termed the ‘short method of Rangan–Scanlon’. However, an analysis of the ‘long method of Rangan–Scanlon’ (Scanlon and Choi, 1999) shows that the value of αis not constant but has small variations that fundamentally depend on the reinforcement ratio and the tensile strength of the concrete. Consequently, the ‘long method’cannot be strictly considered a‘RIS method’. In this study, however, the ‘long method’is grouped with the ‘short method’because it is considered a complement to it that will facilitate the future development of a more definitive version of the ‘short method’. In this study, the ‘long method’of 1999 (Scanlon and Choi, 1999) has been slightly modified, because the values of αand L n /hare formulated as a function of the main variables that affect α. This modification has been performed using the following iterative process. (a) Compute the slenderness of the slab using the ‘short method’and the initial stiffness coefficient, α 0 = 0.52. (b) Compute the required reinforcement ratio for a unit width of the one-way slab (or a unit with of the support band of the two-way slab). (c) Compute the effective moment of inertia (I e ) and the corresponding stiffness coefficient, which is referred to as the modified stiffness coefficient α m =I e /I b . (d) Compare the value of α m that is obtained in step (c) with the value of α 0 that is obtained in step (a). If α 0 =α m , the slenderness can be considered adequate, and α 0 is considered valid. Otherwise, the process is repeated until convergence with α 0 equal to the α m computed in step (c). Despite the work-intensive nature of this version of the ‘long method’, it is useful in this study because it provides slenderness values that are more accurate than would be obtained by the ‘short method’. A considerable number of values of αhave been obtained using this method for the slabs included in this study. Although they are not listed here, the values vary between 0.25 and 0.45, with most of the results concentrated between 0.30 and 0.40. This interval is slightly different from the value 0.52 that was proposed by Scanlon in 2006 (Scanlon and Lee, 2006). Although applying αas a constant is very useful because it enables the use of the ‘short method of Rangan– Scanlon’, the value of αin the ‘short method’should not always take the same value for all members and situations. The values of this coefficient αshould be further evaluated and tabulated as a function of some key variables that control deflection (Sanabra Loewe and Scanlon, 2014). Improvements to the classical equations to calculate deflections are permanently being studied to consider, among other factors, the behaviour of non-rectangular cross-sections (Shaaban and Mustafa, 2019) and the behaviour of new reinforcement solutions (Ge et al., 2020), or to perfect the calculation of the effective moment of inertia (Nguyen et al., 2020). Thanks to the rationality of the method of Rangan–Scanlon, it may be adapted to these advances or to future needs, basically by finding proper values of coefficient α(and potentially of other parameters of the equation). 4. Comparative study of the deflectioncontrol methods A comparative study has been performed to understand better the four deflection-control methods described above and their sensitivities to different parameters. The study is divided into two parts. In the first part, the depths obtained with the different methods are compared considering different typical boundary conditions (simply supported and continuous). In the second part, the sensitivity of the methods is assessed with reference to several key parameters that influence the deflection control (magnitude and duration of superimposed loads, allowable deflection limit and moment redistribution). The methods analysed were developed for different codes that are not directly comparable. Consequently, in this study, materials (concrete and steel) and deflection-control limits are selected to make comparisons possible while maintaining compatibility with the corresponding codes. (Details are provided in Sections A1.1, A1.2 and A1.3 of the Appendix.) 4.1 First part of the study In total, eight variants of the previously discussed methods are examined, as listed below. 5 Structures and Buildings A path to more versatile code provisions for slab deflection control Sanabra-Loewe, Capellà-Llovera, Ramírez-Anaya and Pujadas-Gispert Downloaded by [ Kirsten Buchanan] on [21/03/22]. Copyright © ICE Publishing, all rights reserved. &Method 1: the ACI method, which is a CS method. &Method 2: four variants of the Eurocode 2 methods, as listed next. □Method 2a: the CS method, following Table 7.4N of the Eurocode. □Method 2b: Equation 2, which is a ‘RDS method.’The required tensile reinforcement ratio at mid-span (ρ), which is employed in Equation 2, is based on computing moments considering an elastic behaviour (no moment redistribution). A different ρis obtained for each case, depending on the corresponding diagram of moments. □Method 2c: equivalent to method 2b, but considering a moment redistribution of 15% of the elastic negative moments on bearings. □Method 2d: Equation 2 with a constant tensile reinforcement ratio: ρ= 0.50%. &Method 3: the ‘short method of Rangan–Scanlon’with α= 0.52 (‘RIS method’). &Method 4: two variants of the ‘long method of Rangan– Scanlon’, which is considered a RIS method even if it is not, in the strictest sense. □Method 4a: the required amount of tensile reinforcement is based on computing moments considering an elastic behaviour (no moment redistribution). □Method 4b: the same as method 4a considering a limited moment redistribution of 15% of the negative elastic moments. Results of the first part of the study are displayed in Figures 1 and 2. Figure 1 shows the results for simply supported oneway slabs. Figure 2 shows the results for the interior panels of two-way slabs. Some differences exist in the design and behaviour of one-way and two-way slabs. 4.2 Analysis of results of the first part of the study Regarding the two CS methods 1 and 2a, a certain level of agreement is obtained for simply supported one-way slabs (Figure 1), where Eurocode 2 depths are only 12% smaller than ACI depths. For the interior panels of slabs (Figure 2), the depths of Eurocode 2 are 31% larger than those of ACI. This difference is relevant considering that both codes establish that these depths entitle a designer to avoid actual deflection computations. While actual reinforced concrete deflection computations are not too controversial, such a difference in the two methods, which claim to ‘replace’actual deflection calculations, can only mean that both codes are taking different choices, even if these choices are not explicitly acknowledged. These choices will be further explained in the analysis of the second part of the study. Concerning the sets of data that correspond to Eurocode 2 methods, numerous revealing observations are noted, as shown in Figures 1 and 2. The three sets of data based on the RDS method (methods 2b, 2c and 2d) consistently yield very different results when compared. In both figures, methods 2b and 2d yield the most different depths. The depths of 100 200 300 400 500 600 700 800 900 1000 1100 6 8 10 12 Depth, h: mm Span, L: m Method 1 ACI [L/17.7] Method 2a EC [L/20] Method 2b EC (elastic) (ρ ≈ 0.40–0.30%) {5.4} [Ln/250] Method 2d EC (ρ = 0.50%) Method 3 Short R–S {5.4} [Ln/240] Method 4a Long R–S (elastic) {5.4} [Ln/240] Figure 1. Depth (h) plotted against span (L) for simply supported one-way slabs that are ‘not supporting non-structural damageable elements’(100 mm = 3.94 in; 2 m = 6.56 ft. Note on annotation in key: ACI refers to ACI 318; EC refers to Eurocode 2; short R–S refers to short Rangan–Scanlon method; long R–S refers to long Rangan–Scanlon method; {5.4} is the load case where total superimposed load is 5 kN/m 2 , where sustained loads are 40% of superimposed loads; [L n /…] indicates the allowable incremental deflection of a series; ‘elastic’indicates moment diagrams without moments redistribution; (ρ=…%) indicates reinforcement ratio or range of reinforcement ratios of a series) 6 Structures and Buildings A path to more versatile code provisions for slab deflection control Sanabra-Loewe, Capellà-Llovera, Ramírez-Anaya and Pujadas-Gispert Downloaded by [ Kirsten Buchanan] on [21/03/22]. Copyright © ICE Publishing, all rights reserved. method 2d, on average, are more than 50% larger than those of method 2b, while the ratios of reinforcement of method 2d are only approximately 25% larger than those of method 2b. This finding raises questions regarding the applicability of the method based on Equation 2 without some guidance about the amount of reinforcement, given the considerable influence of this variable. For example, watching the results of series under method 2d for the constant ratio ρ= 0.50%, the large depths that are yielded indicate that the ratio ρ= 0.50% can be considered an upper limit instead of a mean value of ρfor slabs. So, the ratio ρ= 0.50% seems too conservative to be utilised on a general basis to obtain the initial dimension of the depth of slabs. Thus, the series of method 2d with a constant reinforcement ratio of ρ= 0.50% is disregarded for the second part of the study. A notable difference in the results between the sets of data for method 2b and the sets of data for method 2c is observed (Figure 2), particularly for larger spans (10 m (33 ft) or more). A 15% moment redistribution, which is the difference between method 2b and method 2c, causes an increase of 40% in positive reinforcement and an increase of almost 80% in the depth of the slab. This finding shows the enormous influence of an accurate computation of the actual redistribution of moments, which is surprising for a method that establishes the depth of a slab in the early stages of its design. To avoid the high influence of the redistribution of moments on the prediction of depth, one possible approach is suggested: Equation 2 could include the amount of negative moment reinforcement at the bearings, not focusing the formula exclusively on the amount of positive moment reinforcement at the midspan. Considering the four sets of data of Eurocode 2 as a whole, methods 2a, 2b, 2c and 2d in Figures 1 and 2, none of the three sets of data based on the RDS method (methods 2b, 2c and 2d) shows a clear relation with the depths yielded by the CS method (method 2a) of the same Eurocode 2. These results could raise questions regarding the consistency of the two methods (RDS and CS), which are presented as a sole method in this code. Additional observations of the sets of data of the ‘long method of Rangan–Scanlon’(methods 4a and 4b) are feasible. For example, no significant difference is observed between the results of the ‘long method’for elastic diagrams of moments (method 4a) and the results of the ‘long method’for diagrams with a moments redistribution of 15% of the elastic negative moment (method 4b). The results obtained in the two cases are similar. In Figure 2, method 4a cannot be distinguished from method 4b because they are overlapped. Although this situation might be considered a shortcoming of the method, the results are consistent with the fact that Scanlon does not describe the effect of the moments redistribution in the method. Beyond this limitation, the series of the ‘long method’ (methods 4a and 4b) are the series that show better agreement with the results of the two CS methods (methods 1 and 2a), as 100 200 300 400 500 600 700 6 8 10 12 Depth, h: mm Span, L: m Method 1 ACI [Ln/31.3] Method 2a EC [L/24] Method 2b EC (elastic) (ρ ≈ 0.45–0.35%) {5.4} [Ln/500] Method 2c EC (15% moment redistribution) (ρ ≈ 0.65–0.50%) {5.4} [Ln/500] Method 2d EC (ρ ≈ 0.50%) Method 3 Short R–S {5.4} [Ln/480] Method 4a Long R–S (Elastic) {5.4} [Ln/480] Method 4b Long R–S (15% moment redistribution) {5.4} [Ln/480] Figure 2. Depth (h) plotted against span (L) for interior panels of two-way slabs that are ‘supporting non-structural damageable elements.’ (100 mm= 3.94 in; 2 m = 6.56 ft. Note on annotation in key: ACI refers to ACI 318; EC refers to Eurocode 2; short R–S refers to short Rangan–Scanlon method; long R–S refers to long Rangan–Scanlon method; {5.4} is the load case where total superimposed load is 5 kN/m 2 , where sustained loads are 40% of superimposed loads; [Ln/480] and [Ln/500] indicate the allowable incremental deflection of a series; ‘elastic’indicates moment diagrams without moments redistribution; (15% moment redistribution) indicates moments diagrams that consider a 15% of negative moment redistribution; (ρ=…%) indicates reinforcement ratio or range of reinforcement ratios of a series) 7 Structures and Buildings A path to more versatile code provisions for slab deflection control Sanabra-Loewe, Capellà-Llovera, Ramírez-Anaya and Pujadas-Gispert Downloaded by [ Kirsten Buchanan] on [21/03/22]. Copyright © ICE Publishing, all rights reserved. shown in both figures (Figures 1 and 2), especially for short spans. This situation may be a certain proof of its right guess, given the vast experience of the CS methods. Additional details in this are provided in the second part of the study. The results of the ‘short method of Rangan–Scanlon’ (method 3) consistently yield depths that are smaller than those of the ‘long method’(method 4a). For simply supported one-way slabs (Figure 1), approximately 30% smaller depths are obtained; for interior panels of two-way slabs (Figure 2), approximately 10% smaller depths are obtained. This finding may suggest that the value of alpha (α= 0.52) proposed by Scanlon in 2006 (Scanlon and Lee, 2006) and applied in this study in the ‘short method of Rangan–Scanlon’is slightly unconservative. Further investigation may be needed to obtain proper values of αdepending on the main variables that influence deflection calculation and deflection control (Sanabra Loewe and Scanlon, 2014). Considering that the value of α selected for the ‘short method’in this study does not seem to be perfectly tuned, the ‘short method’is not employed in the second part of the study. 4.3 Second part of the study In this part of the study, an assessment is made of the sensitivity of the RDS method of the Eurocode 2 (methods 2b and 2c) and the sensitivity of the ‘long method of Rangan– Scanlon’(method 4a), which is considered an RIS method, to certain key variables: the magnitude and duration of the superimposed loads, the allowable deflection limit and the moment redistribution. As a background the data of series from methods 2b, 2c and 4a are displayed, which are the depths yielded by the CS methods of ACI (method 1) and Eurocode 2 (method 2a). To avoid surcharging the figures with information, the focus has been the ‘long method of Rangan– Scanlon’(method 4a), while series of data of method 2b and method 2c, of Eurocode 2, have been limited to the most representative cases. 4.4 Analysis of results of the second part of the study In Figure 3, devoted to studying the influence of the magnitude of the superimposed loads in the interior panels of twoway slabs, it can be observed how the ‘long method of Rangan–Scanlon’–two curves (method 4a) –regardless of the span, provides an increase in the depths of the slabs of + 20% to + 25% as the superimposed loads are increased 200%, from 5 kN/m 2 to 15 kN/m 2 . Similar increases are observed for the RDS method of Eurocode 2 (methods 2b and 2c). For superimposed loads of 15 kN/m 2 , the curves for method 2b and method 2c of Eurocode 2 in Figure 3 are above and below the curve (method 4a) of the ‘long method of Rangan–Scanlon’. Curves for method 2b and method 2c of Eurocode 2 show similar results for superimposed loads of 5 kN/m 2 . However, the results of the Eurocode 2 for 5 kN/m 2 are not displayed in Figure 3 to avoid excess of data in the figure. 100 200 300 400 500 600 700 800 6 8 10 12 Depth, h: mm Span, L: m Method 1 ACI [Ln/31.3] Method 2a EC [L/24] Method 2b EC (elastic) (ρ ≈ 0.55–0.45%) {15.4} [Ln/500] Method 2c EC (15% moment redistribution) (ρ ≈ 0.85%–0.65%) {15.4} [Ln/500] Method 4a Long R–S (elastic) {5.4} [Ln/480] Method 4a Long R–S (elastic) {15.4} [Ln/480] Figure 3. Depth (h) plotted against span (L) of interior panels of two-way slabs ‘supporting non-structural damageable elements’;to assess the variation in depths yielded by method 2b, method 2c and method 4a to changes in the magnitude of superimposed loads and to changes in the moments redistribution. (100 mm = 3.94 in; 2 m = 6.56 ft. Note on annotation in key: ACI refers to ACI 318; EC refers to Eurocode 2; long R–S refers to long Rangan–Scanlon method; {5.4} is the load case where total superimposed load is 5 kN/m 2 , where sustained loads are 40% of superimposed loads; {15.4} is the load case where total superimposed load is 15 kN/m 2 , where sustained loads are 40% of superimposed loads; [Ln/480] and [Ln/500] indicate the allowable incremental deflection of a series; ‘elastic’indicates moment diagrams without moments redistribution; (15% moment redistribution) indicates moments diagrams that consider 15% of negative moment redistribution; (ρ=…%) indicates reinforcement ratio or range of reinforcement ratios of a series) 8 Structures and Buildings A path to more versatile code provisions for slab deflection control Sanabra-Loewe, Capellà-Llovera, Ramírez-Anaya and Pujadas-Gispert Downloaded by [ Kirsten Buchanan] on [21/03/22]. Copyright © ICE Publishing, all rights reserved. In Figure 3, the method of Eurocode 2 (methods 2b and 2c) is dependent on knowing in advance the amount of moment redistribution, which is consistent with the findings in the first part of the study. A 15% moment redistribution increases the positive reinforcement by 50%, and causes an increase in the depth of floors of 30%. Beyond the particular issue with the moment redistribution that the method of Eurocode 2 has, both methods (Eurocode 2 and the ‘long method of Rangan–Scanlon’) yield reasonable increases in depth when the loads are increased. This result contrasts with constant depth methods of the ACI (method 1) and Eurocode 2 (method 2a), which have no criteria or poor criteria for addressing the magnitude of the load. Comparing the results of the CS methods of the ACI (method 1) and Eurocode 2 (method 2a) with those of the other two more refined methods, in particular with the ‘long Rangan–Scanlon method’, several observations are noted. First, the depths of the ACI method (method 1) seem slightly unconservative or tuned only for short spans (around 6 m) and light loads (less than 5 kN/m 2 ). This result is consistent with the findings of Bondy 1 and the comment in section R8.3.1 of the ACI code, which acknowledges that the constant slenderness given in the code may not be suitable in the case of ‘unusually heavy’loads. However, ‘usual’or ‘unusual’loads are not defined. Second, the depths of Eurocode 2 (method 2a) seem well tuned for moderate spans (just under 10 m) with superimposed loads of 5 kN/m 2 , similar to those in the lower bound curve of the ‘long Rangan–Scanlon method’ (method 4a) in Figure 3. In the same figure, for short spans (6 m), Eurocode 2 seems to be tuned for higher loads (nearer 10 kN/m 2 ). This result is consistent with note 1 in table 7.4N of Eurocode 2, which is the table that defines method 2a. Note 1 acknowledges that the values in table 7.4N ‘have been chosen to be generally conservative and calculation may frequently show that thinner members are possible’. The two short comments in the previously mentioned codes, in addition to the comparison with the results of the refined methods, would put forward the very different choices taken by the two codes (31% in difference of depths) to address the same problem: the poor capacity of CS methods to adjust the results to an increase in the superimposed loads. In both codes, the constant depth ratios (methods 1 and 2a) are primarily tuned for short or moderate spans (less than 10 m). These ratios seem to disregard the fact that the increase in span exponentially affects the deflection and should cause increases in depth accordingly, just as more refined methods are able to do: the RDS method of Eurocode 2 (methods 2b and 2c) and the ‘long method of Rangan–Scanlon’(method 4a). The ACI seems to be tuned for short spans (around 6 m) and light loads, while Eurocode 2 seems to be tuned for moderate spans (around 8 m) and moderately high loads. Thus, following the ACI provisions without calculating deflections may produce economic floors for domestic spans and loads, while following the Eurocode 2 provisions may produce uneconomic floors for domestic spans and loads. However, possibly the ACI does not clearly warn of potential excessive deflection for larger spans or larger loads, and Eurocode 2 does not clearly warn of potentially expensive and unnecessarily polluting floors for domestic loads and spans. Figure 4 shows that an increase in the proportion of sustained superimposed load without varying the total load has a negligible influence on the depths of slabs that are obtained with the ‘long method’(method 4a). The RDS method of Eurocode 2 (methods 2b and 2c) continues yielding very different depths depending on the redistribution of moments. The results of the RDS method of Eurocode 2 (methods 2b and 2c) are approximately above and below the results of the ‘long method of Rangan–Scanlon’(method 4a). Figure 5 shows that a less restrictive deflection limitation (e.g. L n /250 for roofs) reduces the depths obtained with the ‘long method of Rangan–Scanlon’(method 4a). Allowing a double deflection causes a 20% reduction in the depth of the slab, which seems reasonable. In contrast, the RDS method of Eurocode 2 (methods 2b and 2c) does not adequately address this situation. This is explained because a relaxation of the allowable deflection typically causes a reduction in depth, while superimposed loads are kept constant. As a result, the amount of reinforcement is increased. In the RDS method of Eurocode 2, additional reinforcement causes an increase in depth (refer to Figure 5), which is not the desired result. 5. Conclusions and recommendations for codes provisions Establishing the depth of a slab as the first step of its design is a common practice as a means to control its deflection. This decision in the early stages of design has a major importance from both the economic point of view and the environmental point of view, as well as from the serviceability point of view. Thus, improvements in this simple early phase of design can have a relevant influence and should be regarded by code developers as a way to improve the efficiency and sustainability of structures. Improving this part of the codes should not be too labour intensive from the scientific point of view, but could be highly influential on general practice. This study compares three families of simplified deflectioncontrol methods for the design of one-way and two-way reinforced concrete slabs, including the provisions of the ACI 318 code and the Eurocode 2 code for minimum depth provisions. In these codes, the depth (h) of the slab is established as related to the span (L) using the concept of slenderness (L/h). 9 Structures and Buildings A path to more versatile code provisions for slab deflection control Sanabra-Loewe, Capellà-Llovera, Ramírez-Anaya and Pujadas-Gispert Downloaded by [ Kirsten Buchanan] on [21/03/22]. Copyright © ICE Publishing, all rights reserved.