scieee AI-readable full text Open interactive document viewer

Numerical study of fluidic oscillators with compressible flow

Guilleumes Mayoral, Pau

Abstract

1. Documentación y estudio del estado del arte. 2. Aprendizaje de los conceptos básicos de la Mecánica de Fluidos Computacional. 3. Aprendizaje del software OpenFOAM. 4. Mallado del oscilador fluídico de referencia. 5. Lanzamiento de las simulaciones. 7. Extracción y análisis de resultados, comparándolos con los resultados obtenidos en simulaciones con flujo incompresible. 8. Conclusiones.

Full text

ETSEIAT GrETA Grau en Enginyeria en Tecnologies Aeroespacials Numerical study of fluidic oscillators with compressible flow Author: Pau Guilleumes Mayoral Director: David del Campo Sud Co-director: Vanessa del Campo Gatell Delivery date: 10-01-2017 REPORT CONTENTS Contents List of Tables 4 List of Figures 5 1 Aim of the study 8 2 Scope of the study 9 3 Requirements of the study 10 4 Justification 11 4.1 Identificationoftheneed............................... 11 4.2 Usefulnessoftheproject ............................... 11 5 Background 12 5.1 Fluidics ........................................ 12 5.2 Fluidicoscillators................................... 15 5.2.1 Bi-stable fluidic oscillators . . . . . . . . . . . . . . . . . . . . . . . . . . 17 5.2.1.1 Double feedback loop fluidic oscillators . . . . . . . . . . . . . . 18 5.2.1.2 Single feedback loop fluidic oscillators . . . . . . . . . . . . . . . 18 5.2.2 Feedback free fluidic oscillators . . . . . . . . . . . . . . . . . . . . . . . 19 6 State of the art 21 6.1 TUBerlininvestigation................................ 21 6.2 ETSEIATinvestigation................................ 25 6.2.1 Bi-dimensional and three-dimensional studies . . . . . . . . . . . . . . . 25 6.2.2 Parameters variation studies . . . . . . . . . . . . . . . . . . . . . . . . . 28 6.2.3 Compressible flow studies . . . . . . . . . . . . . . . . . . . . . . . . . . 30 7 Theoretical framework 33 7.1 Fluid dynamics fundamentals . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 7.2 Turbulence....................................... 37 7.2.1 Boussinesq hypothesis . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 7.2.2 LES ...................................... 40 7.2.3 RANS ..................................... 41 7.2.4 Thin Shear Layer approximation (TSL) . . . . . . . . . . . . . . . . . . . 43 Pau Guilleumes Mayoral R - 1 CONTENTS 7.2.5 Parabolic approximations . . . . . . . . . . . . . . . . . . . . . . . . . . 44 7.2.6 Boundary Layer approximation . . . . . . . . . . . . . . . . . . . . . . . 44 7.2.7 Distributed Loss model . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 7.2.8 Viscous-inviscid interaction models . . . . . . . . . . . . . . . . . . . . . 45 7.2.9 Time-dependant Euler equations . . . . . . . . . . . . . . . . . . . . . . 45 7.2.10Potentialflowmodel ............................. 45 7.3 TheCoandaEffect .................................. 46 7.3.1 Mechanism of Coanda Effect . . . . . . . . . . . . . . . . . . . . . . . . . 47 7.4 CFD.......................................... 48 7.4.1 CFDdesigncycle............................... 49 7.4.2 Spacediscretization.............................. 50 7.4.2.1 The Finite Difference Method . . . . . . . . . . . . . . . . . . . 51 7.4.2.2 The Finite Element Method . . . . . . . . . . . . . . . . . . . . 53 7.4.2.3 The Finite Volume Method . . . . . . . . . . . . . . . . . . . . 55 7.4.3 Timediscretization.............................. 57 7.4.3.1 Explicit discretization scheme . . . . . . . . . . . . . . . . . . . 58 7.4.3.2 Implicit discretization scheme . . . . . . . . . . . . . . . . . . . 59 7.4.3.3 Hybrid discretization schemes . . . . . . . . . . . . . . . . . . . 59 7.4.4 IterativeMethods............................... 60 7.4.4.1 Basic iterative methods . . . . . . . . . . . . . . . . . . . . . . 60 7.4.4.2 Overrelaxation methods . . . . . . . . . . . . . . . . . . . . . . 62 7.4.4.3 Multigrid methods . . . . . . . . . . . . . . . . . . . . . . . . . 62 7.4.5 OpenFOAMR ................................. 63 8 Problem approach 66 8.1 Oscillator characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 8.1.1 Stages of the oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 8.2 Turbulencemodel................................... 69 8.3 Experimentconditions ................................ 70 9 Geometry 72 9.1 Geometry3Dmodelling ............................... 72 9.2 Geometrymeshing .................................. 72 9.2.1 Meshingprogress ............................... 72 9.2.2 Meshcharacteristics ............................. 75 10 Simulation 77 10.1 Simulation parameters and implementation . . . . . . . . . . . . . . . . . . . . . 77 Pau Guilleumes Mayoral R - 2 CONTENTS 10.1.1Constantparameters............................. 77 10.1.1.1 Thermophysical properties . . . . . . . . . . . . . . . . . . . . . 77 10.1.1.2 Turbulence properties . . . . . . . . . . . . . . . . . . . . . . . 78 10.1.2Initialconditions ............................... 78 10.1.2.1 U................................... 79 10.1.2.2 T................................... 79 10.1.2.3 p................................... 79 10.1.2.4 k................................... 79 10.1.2.5 ω................................... 79 10.1.2.6 αt.................................. 80 10.1.2.7 νt................................... 80 10.1.3Systemparameters .............................. 80 10.1.3.1 controlDict ............................. 80 10.1.3.2 fvSchemes.............................. 81 10.1.3.3 fvSolution.............................. 82 10.1.3.4 decomposeParDict . . . . . . . . . . . . . . . . . . . . . . . . . 83 10.2 Variations on the simulation parameters . . . . . . . . . . . . . . . . . . . . . . 83 11 Results 84 12 Organization and planning 89 12.1Workbreakdown ................................... 89 12.2Futurework...................................... 89 13 Environmental impact 91 14 Conclusions and recommendations 92 15 Bibliography 93 Pau Guilleumes Mayoral R - 3 LIST OF TABLES List of Tables 5.1 Advantages and disadvantages of fluidic flow control actuators . . . . . . . . . . 15 6.1 Oscillatior frequency comparison between the turbulent models, from Bobusch, B.[1].......................................... 24 6.2 Boundary conditions, experimental and numerical results obtained by Bobusch, B. [1] (SST turbulence model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 6.3 Numerical results obtained by Ruiz, M. [2] . . . . . . . . . . . . . . . . . . . . . 26 10.1Locationoftheprobes ................................ 81 10.2 Schemes used for the RAS K-ωSSTsimulation .................. 81 11.1 Inlet and internal field Mach values and simulation parameters . . . . . . . . . . 85 Pau Guilleumes Mayoral R - 4 LIST OF FIGURES List of Figures 5.1 Tesla’s Valvular Valve patent US-1329559 [3] . . . . . . . . . . . . . . . . . . . . 12 5.2 Tesla’s Valvular valve principle of operation, from US patent US-1329559 [3] . . 12 5.3 Classification of AFC actuators, from Cattafesta, L. N. [4] . . . . . . . . . . . . 14 5.4 Fluidic array (a) integration into the leading edge (b) or the trailing edge (c) of an airfoil, from Raghu, S. [5] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 5.5 Windshield fluid dispenser, US Patent 4157161, from Bauer, P. [6] . . . . . . . 16 5.6 Typical bi-stable fluidic oscillator configuration, from Tesař, V. [7] . . . . . . . . 17 5.7 Double feedback loop fluidic oscillator configuration, from Warren, W. [8] . . . . 18 5.8 Oscillator with single feedback loop, from Spyropoulos, C. E. [9] . . . . . . . . . 19 5.9 Feedback free fluidic oscillator schemes, US Patent 6253782 B1, from Raghu, S. [10]........................................... 19 5.10 Feedback free fluidic oscillator phases 0◦and 180◦, US Patent 6253782 B1, from Raghu,S.[10]..................................... 19 5.11 Feedback free fluidic oscillator with water supply, from Gregory, S. W. et al. [11] 20 6.1 a) Experimental sketch of the test rig used. b) Pressure ports distribution. From Bobusch,B.[1] .................................... 21 6.2 Experimental setup photograph from Bobusch, B. [1] . . . . . . . . . . . . . . . 22 6.3 3D and 2D CFD model comparison, adapted from Bobusch, B. [1] . . . . . . . . 22 6.4 Medium density 2D mesh, 166782 nodes, from Bobusch, B. [12] . . . . . . . . . 23 6.5 Linear dependence between Re and frequency, adapted from Bobusch, B. [12] . . 25 6.6 Comparison between Bobusch, B. numerical and experimental results and Ruiz, M. numerical results, from Ruiz, M. [2] . . . . . . . . . . . . . . . . . . . . . . . 26 6.7 Z-direction 12 layers distribution, from Calviño, P. [13] . . . . . . . . . . . . . . 27 6.8 Comparison between experimental and numerical (2D and 3D) results from Calviño,P.[13] .................................... 27 6.9 Geometry modifications of the fluidic oscillator, from Saramiento, M. [14] . . . . 28 6.10 Inlet throat angle versus frequency, adapted from Saramiento, M. [14] . . . . . . 29 6.11 Inlet throat amplitude versus frequency, adapted from Saramiento, M. [14] . . . 29 6.12 Outlet throat amplitude versus frequency, adapted from Saramiento, M. [14] . . 29 6.13 Outlet throat angle versus frequency, adapted from Saramiento, M. [14] . . . . . 29 6.16 Frequency of the oscillator against the angle variations in %, adapted from Candelo,C.A.[15].................................. 29 6.14 Outlet throat angle sketch, from Candelo, C. A. [15] . . . . . . . . . . . . . . . . 30 6.15 Outlet throat angle, simulation view by Candelo, C. A. [15] . . . . . . . . . . . . 30 Pau Guilleumes Mayoral R - 5 LIST OF FIGURES 6.17 Analysis of the axis of symmetry under compressible conditions from Candelo, C.A.[15] ....................................... 30 6.18 Analysis of the upper outlet channel under compressible conditions from Candelo, C.A.[15] ....................................... 31 6.19 Pressure distribution in the outlet channel, incompressible flow, adapted from Candelo,C.A.[15].................................. 32 6.20 Pressure distribution in the outlet channel, compressible flow, adapted from Candelo,C.A.[15].................................. 32 7.1 Hierarchy of the different dynamical levels of approximation from Hirsch, C. [16] 39 7.2 Instantaneous and average velocity in turbulent flow from Sayma, A. [17] . . . . 41 7.3 Range of application of DNS, LES, RANS models and energy spectrum of turbulence in function of k, from Hirsch, C. [16] . . . . . . . . . . . . . . . . . . 43 7.4 NOTARR system sketch by MD Helicopters [18] . . . . . . . . . . . . . . . . . 47 7.5 Explanation of the Coanda Effect from Iguchi, M. et al. [19] . . . . . . . . . . . 48 7.6 Taylor expansion of (e√x−1) up to order 5 from Hirsch, C. [16] . . . . . . . . . 52 7.7 Finite difference discretization method from Sayma, A.[17] . . . . . . . . . . . . 52 7.8 Subdivisions Ω1,Ω2,Ω3, of the volume Ωfrom Hirsch, C.[16] . . . . . . . . . . . 56 7.9 a) Jacobi method scheme, b) Gauss-Seidel method scheme. From Hirsch, C. [16] 61 8.1 Bi-stable fluidic oscillator flow regions scheme from Ruiz, M. [2] . . . . . . . . . 67 8.2 CFD simulation results of the flow in a fluidic oscillator, phase φ= 0◦from Krüger,O.[20]..................................... 68 8.3 CFD simulation results of the flow in a fluidic oscillator, phase φ= 90◦from Krüger,O.[20] .................................... 68 8.4 CFD simulation results of the flow in a fluidic oscillator, phase φ= 180◦from Krüger,O.[20] .................................... 68 8.5 CFD simulation results of the flow in a fluidic oscillator, phase φ= 270◦from Krüger,O.[20] .................................... 69 9.1 Geometry of the fluidic oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . 72 9.2 Geometry of the fluidic oscillator . . . . . . . . . . . . . . . . . . . . . . . . . . 72 9.3 Basic castellated mesh using snappyHexMesh utility................ 73 9.4 Basic snapped mesh using snappyHexMesh utility ................. 74 9.5 Finest mesh created using snappyHexMesh with irregularities on the external faces(a)........................................ 74 9.6 Finest mesh created using snappyHexMesh with irregularities on the external faces(b)........................................ 74 9.7 Final mesh by Baghaie, M. using blockMesh utility (a) . . . . . . . . . . . . . . 75 9.8 Final mesh by Baghaie, M. using blockMesh utility (b) . . . . . . . . . . . . . . 75 Pau Guilleumes Mayoral R - 6 LIST OF FIGURES 9.9 Final mesh by Baghaie, M. using blockMesh utility (c) . . . . . . . . . . . . . . 75 9.10 Final mesh by Baghaie, M. using blockMesh utility (d) . . . . . . . . . . . . . . 75 11.1 Mach values of the initial simulation internal field . . . . . . . . . . . . . . . . . 84 11.2 Pressure values of the initial simulation internal field . . . . . . . . . . . . . . . 85 11.3 Evolution of the pressure field in the probe locations of Mach 0.10 simulation . . 86 11.4 Evolution of the pressure field in the probe locations of Mach 0.10 simulation . . 86 11.5 Mach values of the internal field of the M=0.10 simulation before failure . . . . 87 11.6 Initial false Mach values of the internal field of the M=0.10 simulation . . . . . . 87 11.7 Final false Mach values of the internal field of the M=0.10 simulation . . . . . . 88 Pau Guilleumes Mayoral R - 7 5.1 Fluidics Figure 5.3: Classification of AFC actuators, from Cattafesta, L. N. [4] The advantages and disadvantages of the fluidic flow control actuators can be found in table 5.1 Pau Guilleumes Mayoral R - 14 5.2 Fluidic oscillators Table 5.1: Advantages and disadvantages of fluidic flow control actuators Type Subtype Advantages Disadvantages Fluidic ZNMF Requires no external fluid source Peak velocities typically limited to low to moderate subsonic speeds Amenable to various types of drivers and sizes Resonant devicies Suitable for feedback control Valves Capable of high velocities with either fast time response or high bandwidth but generally not both May not be amenable to feedback control Requires an external flow source Oscillators Capable of producing large disturbances Standard versions not suitable for feedback control Amenable to a range of sizes and hence frequencies Requires an external flow source Potential extensions possible to enable independent control of frequency and velocity Combustion Capable of producing large perturbations in high-speed flows Currently limited to relatively low frequencies (a few hundred hertz) Requires combustion 5.2 Fluidic oscillators Fluidic oscillators are a major advance in the active flow control field. They belong to the most common type of ACF actuators, the fluidic actuators, which uses fluid suction or injection to increase momentum in the local flow field. They have been increasingly often used in numerous different applications, such as the boundary layer control on either wing and turbine airfoils 5.4, high-lift devices, and all kind of aerodynamic surfaces, but they have been commonly used for several years on automobiles as a wind-shield washer fluid dispenser [6]. Figure 5.4: Fluidic array (a) integration into the leading edge (b) or the trailing edge (c) of an airfoil, from Raghu, S. [5] Pau Guilleumes Mayoral R - 15 5.2 Fluidic oscillators Figure 5.5: Windshield fluid dispenser, US Patent 4157161, from Bauer, P. [6] Fluidic oscillators generate a periodic oscillating jet, when it is supplied with a fluid at a certain pressure and velocity. That is to say, its working principle is based on the bi-stable states of a single jet or a pair of jets of fluid inside a specially designed flow chamber. These produce sweeping or pulsing jets on the outlet. [5] The main advantage of a fluidic oscillator against other flow control devices is that it has no moving parts: the oscillating jet is created only by means of fluid-dynamic interactions. That makes it much more plausible to be used into flight vehicles rather than any other AFC system, because it has a reduced risk of failure, as well as the costs and the complexity of the device. Pau Guilleumes Mayoral R - 16 5.2 Fluidic oscillators There is three different types of fluidic oscillators: 1. Bi-stable fluidic oscillator (a) Double feedback loop (b) Single feedback loop 2. Feedback free fluidic oscillator 5.2.1 Bi-stable fluidic oscillators The bi-stable fluidic oscillators, or wall attachment devices, are based on the fluid jet attachment to an adjacent wall in a divergent nozzle or in an internal chamber, provided by the Coanda Effect (explained in section 7). The attached flow can be released and attached to the opposite wall if a feedback mechanism is used. A pressure pulse perpendicular to the attached jet from the control port induces an unattachment and the following attachment to the opposite adjacent wall due to the recirculation bubble created next to the inner blocks wall, and the process is repeated with a pressure pulse from the other control port, resulting in an oscillating flow. This behaviour was first discovered by [22]. The exiting jet can be divided by a plate in the middle, creating in this way two pulsing jets. If the control port flow comes from the outlet nozzle, it is called feedback channel or loop. Figure 5.6: Typical bi-stable fluidic oscillator configuration, from Tesař, V. [7] Pau Guilleumes Mayoral R - 17 5.2 Fluidic oscillators 5.2.1.1 Double feedback loop fluidic oscillators This is one of the oldest fluidic oscillator designs, originally discovered at the Harry Diamond Laboratories (HDL) [21]. It has been widely used since then in multiple applications. It is also called "seeping jet actuator" because of the characteristic flow at the outlet, or "Warren’s circuit", due to the denomination of the feedback channels, called Warren feedback loops [8]. Part of the flow is removed from the output (or at the end of the mixing chamber) and brought back upstream by the feedback channel into the control port nozzle of the same side. Recent investigations are implementing it in arrays for flow control purposes with air, after some tests a V-22 wing showed promising results [23]. Figure 5.7: Double feedback loop fluidic oscillator configuration, from Warren, W. [8] 5.2.1.2 Single feedback loop fluidic oscillators It is, by far, less used than the double feedback configuration. The single feedback loop fluidic oscillator uses the pressure difference between the two control ports when the jet is deflected, in order to generate the recirculating bubble that unattaches the main flow from the wall and create the oscillations. It was presented by Spyropoulos [9] (this is where the loops name come from, figure 5.8) but the device was patented by Warren. Pau Guilleumes Mayoral R - 18 5.2 Fluidic oscillators Figure 5.8: Oscillator with single feedback loop, from Spyropoulos, C. E. [9] 5.2.2 Feedback free fluidic oscillators On the other hand, there is the feedback free fluidic oscillators, or jet interaction devices. These come from recent studies and research, and consist in the interaction of two fluid jets inside the mixing chamber, specially designed to achieve the desired properties of the oscillator (frequency, amplitude, etc.). The power nozzles are connected to at least one source of fluid under pressure. The exit throat can be off axis (off the central axis of the symmetry) by a small fraction to the left or right to move the leftward or rightward yaw angles in the spray. Figure 5.9: Feedback free fluidic oscillator schemes, US Patent 6253782 B1, from Raghu, S. [10] Figure 5.10: Feedback free fluidic oscillator phases 0◦and 180◦, US Patent 6253782 B1, from Raghu, S. [10] Pau Guilleumes Mayoral R - 19 5.2 Fluidic oscillators Figure 5.11: Feedback free fluidic oscillator with water supply, from Gregory, S. W. et al. [11] Pau Guilleumes Mayoral R - 20 Section 6: State of the art 6 State of the art Several studies have been done on fluidic actuators, a lot of them performing numerical or CFD models, under laminar conditions as well as considering a turbulent flow. 6.1 TU Berlin investigation The most recent work which this study is based on was carried on by the Technische Universität Berlin, leaded by Bernhard Bobusch [1]. It is either a numerical and experimental study. The methodology used in the experimental part was a PIV (particle image velocity), used in fluidics with the purpose of visualisation instantaneous velocities and other physical magnitudes. Even though in his applications in the aeronautic field (for flight vehicles) the inner flow of the device is air, this study was made with water due to its superior optical characteristics, in order to make easier the data acquisition (it makes the measurements with laser easier to make). In figures 6.1 and 6.2 the experimental setup can be appreciated. The flow comes through a pipe pumped by a small pump from the aquarium and enters into the device, made of acrylic glass, placed in the water tank 10cm underneath the fluid surface. A CCD-Camera together with a laser, and a hydrophone are used for the data acquisition. Figure 6.1: a) Experimental sketch of the test rig used. b) Pressure ports distribution. From Bobusch, B. [1] Pau Guilleumes Mayoral R - 21 6.1 TU Berlin investigation Figure 6.2: Experimental setup photograph from Bobusch, B. [1] In figure 6.1 b) and 6.2, it can be seen the pressure ports around the mixing chamber, the feedback channels and the outlets where data acquisition is made, and where velocity distribution comparisons are considered. Figure 6.3: 3D and 2D CFD model comparison, adapted from Bobusch, B. [1] Regarding the numerical approach of Bobusch, B. [1], a bi-dimensional and a three-dimensional mesh were used (to find out the significance of the differences between the two models - figure 6.3), and the simulations were carried out using ANSYS FluentR . At the beginning, three meshes of different density were designed: Pau Guilleumes Mayoral R - 22 6.1 TU Berlin investigation •High density mesh: 442986 nodes •Medium density mesh: 166782 nodes •Low density mesh: 41000 nodes Figure 6.4: Medium density 2D mesh, 166782 nodes, from Bobusch, B. [12] After validating the results of each one of the meshes, and doing the computational balance, a conclusion was reached that the optimal mesh was the medium density mesh (figure 6.4). In order to perform the simulations, various turbulence models were tested and compared in terms of accuracy: •Spallart-Almaras model •Reynolds Stress model (RSM) •Shear Stress Transport (SST) •Scale Adaptative Simulation (SAS) •Detached Eddy Simulation (DES) The difference between the frequency values obtained with each turbulence model can be appreciated in the following table 6.1. The optimal turbulent models are the Shear Stress model (SST) and the Detached Eddy Simulation (DES). It was finally decided to use the SST model due to the shorter time required for computing. Pau Guilleumes Mayoral R - 23 6.2 ETSEIAT investigation Figure 6.14: Outlet throat angle sketch, from Candelo, C. A. [15] Figure 6.15: Outlet throat angle, simulation view by Candelo, C. A. [15] 6.2.3 Compressible flow studies In addition, the project made by Candelo, C. A. [15] included a numerical analysis with compressible flow, to evaluate how does the fluidic oscillator work under different conditions. As in the aerospace industry (among other fields), it shall be used with air, it was very important to not simply test it with water, but also with this gas. The study comprehends just one simulation with a reference velocity of the flow of 0.67 m/s, and a detailed study of the effects on the device. The results of the analysis correspond to two different lines in the geometry: •Axis of symmetry of the fluidic oscillator 6.17 •Upper outlet channel of the fluidic oscillator 6.18 Figure 6.17: Analysis of the axis of symmetry under compressible conditions from Candelo, C. A. [15] Pau Guilleumes Mayoral R - 30 6.2 ETSEIAT investigation Figure 6.18: Analysis of the upper outlet channel under compressible conditions from Candelo, C. A. [15] On the one side, according to the the axial symmetry analysis, it was concluded that the pressure distribution is completely different in both cases, compressible and incompressible. When feeded with air (compressible), the fluidic oscillator presents two clear high pressure zones, the inlet throat and the walls of the outlet throat where the fluid collides at the end of the mixing chamber. This high pressure areas cannot be distinguished in the incompressible case. On the other side, referring to the upper outlet channel analysis, both cases presented again a completely different pressure distribution. The incompressible case experimented a sudden drop of the pressure, but it recovered as fast as it had dropped, to reach the final value that remains almost constant until the end of the outlet (figure 6.19). But in the compressible case, the pressure dropped at light strokes, maintaining at certain points a constant value (figure 6.20). Pau Guilleumes Mayoral R - 31 6.2 ETSEIAT investigation Figure 6.19: Pressure distribution in the outlet channel, incompressible flow, adapted from Candelo, C. A. [15] Figure 6.20: Pressure distribution in the outlet channel, compressible flow, adapted from Candelo, C. A. [15] Pau Guilleumes Mayoral R - 32 Section 7: Theoretical framework 7 Theoretical framework 7.1 Fluid dynamics fundamentals In the fluid dynamics field, the fluid is considered as continuum, and it has properties such as density, pressure or temperature. It means that the behaviour of individual molecules is neglected, so what matters is an average over the fluid elements. The fundamental equations that govern the behaviour of a fluid flow are made basically of differential equations which represent the interdependence between the different variables, and how they evolve in time and space. Also, they can be complemented by algebraic relations, like when working with compressible flow with the equation of state. The governing equations for compressible flow are: •The continuity equation 7.2 •The momentum equations (Navier-Stokes) 7.3 7.4 7.5 •The energy equation 7.8 The terms of these equations are u, ν, w, the velocity components in the x, y, z directions, the density ρ, the temperature T, the static pressure p, the dynamic viscosity µand Cpthe specific heat at constant pressure. These equations are all conservation laws. The conservation law for a quantity U states: The variation of the total amount of a quantity U inside a given domain is equal to the balance between the amount of that quantity entering and leaving the considered domain, plus the contributions from eventual sources generating that quantity [16]. The equation of the integral form of the previous statement can be written as: ∂ ∂t ZΩUdΩ + IS ~ F·d~ S=ZΩQdΩ (7.1) The continuity equation (also known as Mass Conservation Equation, or 1st conservation law) defends the empirical fact that matter is conserved in a fluid system, it cannot be created nor destroyed. That is to say: Pau Guilleumes Mayoral R - 33 7.1 Fluid dynamics fundamentals Per unit volume, the sum of all masses flowing in and out per unit time must be equal to the change of mass due to change in density per unit time [17] It can be applied at each point in a fluid and to all fluids, both compressible and incompressible flows, and Newtonian and non-Newtonian fluids: −∂ρ ∂t =∂(ρu) ∂x +∂(ρν) ∂y +∂(ρw) ∂z (7.2) The momentum equation 7.3 7.4 7.5 is defined as the product of the density and the velocity, so it is a vector with three components in space that make a total of three equations. They are also called Navier-Stokes equations, and together with the continuity equations are the basis for the fluid dynamics analysis. They follow Newton’s second law of motion, that can be equally applied to solids, as well as to liquids and gases, with the only difference that fluids distort without limit. Navier-Stokes equations state that: The inertial forces acting on a fluid element are balanced by the surface and body forces [17] ρ ∂u ∂t +u∂u ∂x +ν∂u ∂y +w∂u ∂z !=−∂p ∂x +µ ∂2u ∂x2+∂2u ∂y2+∂2u ∂z2!+Fx(7.3) ρ ∂ν ∂t +u∂ν ∂x +ν∂ν ∂y +w∂ν ∂z !=−∂p ∂y +µ ∂2ν ∂x2+∂2ν ∂y2+∂2ν ∂z2!+Fy(7.4) ρ ∂w ∂t +u∂w ∂x +ν∂w ∂y +w∂w ∂z !=−∂p ∂z +µ ∂2w ∂x2+∂2w ∂y2+∂2w ∂z2!+Fz(7.5) It is necessary to define the sources that influence the variation of momentum, in order to understand the physical significance of each term of the equations. The sources of the variation of momentum are the forces acting on the physical system that can be external (~ fe) or internal (~ fi). The internal forces act as sources in the surface, as all the other internal forces are cancelled due to the action = reaction rule. The terms placed in the left side of the equation correspond to the inertial terms, arising from the changes in the momentum. They give a measure of the velocity change of one fluid element through space (∂/∂t is the local derivative and gives the variation at a fixed point, Pau Guilleumes Mayoral R - 34 7.1 Fluid dynamics fundamentals and the remaining three terms grouped together are called convective terms or convective differential). On the other side of the equation, the countering terms are the pressure gradient (∂p/∂x), the viscous shear stress (always retarding the flow) and if there are any, body forces such as the gravitational or magnetic force, among many others. The Navier-Stokes equations can be applied too in a turbulent flow analysis, if the appropriate modifications are introduced. It has to be noticed that the convective term is non-linear. This term has great responsibility for the appearance of turbulence. The vectorial form of the momentum conservation equations in an inertial frame of reference, with the forces acting on the body decomposed, is the following: ∂ ∂t(ρ~v) + ∇ · (ρ~v~v) = −∇p+∇ · (τ) + ρ~g +~ F(7.6) where ρg is the gravitational body force, ~ Frepresents the external body forces and τis the stress tensor, defined as follows with Ias a unit tensor: τ=µ(∇~v +∇~vT)−2 3∇ · ~vI(7.7) Finally, the Energy Conservation Equation 7.8, which follows the 1st law of thermodynamics, state that: The total energy within the domain remains constant, so the rate of change equals the sum of the heat addition and the work done. The volume sources (as they have been defined in the general transport law), correspond to the sum of the work of the volume forces ~ feand the heat sources other than conduction (chemically released heat, radiation, etc.). The surface sources, similar to the momentum equation, are the result of the work done on the fluid by the internal shear stresses acting on the surface of the volume [16]. ρcp ∂T ∂t +u∂T ∂x +ν∂T ∂y +w∂T ∂z != Φ + ∂ ∂x "k∂T ∂x #+∂ ∂y "k∂T ∂y #+∂ ∂z "k∂T ∂z # + u∂p ∂x +ν∂p ∂y +w∂p ∂z!(7.8) Pau Guilleumes Mayoral R - 35 7.1 Fluid dynamics fundamentals The coefficient kis the thermal conductivity coefficient that comes from the Fourier’s law of heat conduction: ~ FD=−k~ ∇T(7.9) where Tis the absolute temperature and ~ FDthe diffusive flux of energy. There is also the relation k=ρCpκ=µCp/Pr (7.10) Pr =ν/κ =µCp/k (7.11) where Pr is the Prandtl number and κis the thermal diffusivity, empirically defined together with the dynamic viscosity µ. Φis the energy dissipation function that follows the equation: Φ=2µ  ∂u ∂x!2 + ∂ν ∂y !2 + ∂w ∂z !2 + 0.5 ∂u ∂y +∂ν ∂x!2 + 0.5 ∂ν ∂z +∂w ∂y !2 + 0.5 ∂w ∂x +∂u ∂z !2  −2 3µ ∂u ∂x +∂ν ∂y +∂w ∂z !2 (7.12) If the viscosity and the specific heat are considered as constant, the resulting system of equations contain 6 unknowns, and has 5 equations, so a further equation is needed. The usual way to close the system is using a constitutive relation for the pressure, i.e. the ideal gas equation where Ris the gas constant: p=ρRT (7.13) If some other complex phenomena is added to the problem to solve such as combustion, multiphase flows, chemical reactions, multi-species flows with condensation, evaporation, bursting or agglomeration of gas bubbles or liquid drops, or others, some further eqautions are needed to model the physical laws that describe all of those phenomena. For example, the chemical species transport equation that has tu be used if there is combustion is the following: Pau Guilleumes Mayoral R - 36 7.2 Turbulence ∂ ∂t (ρYk) + ∂ ∂xj (ρYkuj) = ∂ ∂xj ρDk ∂Yk ∂xj!+Sk(7.14) 7.2 Turbulence The different fluid flows that can be easily found in the nature, but also in the laboratory or in the industry, they are usually turbulent. During the 1880’s, Reynolds, O. discovered while carrying out some visualisation studies of a flow in a pipe, that the laminar flow degenerated into a chaotic motion after reaching certain velocity. This event was linked to a non-dimensional quantity called Reynolds number (Re) after its discoverer. Re =ρUD µ(7.15) It represents the ratio between inertia forces and viscous forces. For a low Re, the flow runs with order in parallel streamlines. If it is increased, the flow becomes turbulent from certain Reynolds number, not necessarily very high, and the laminar structure is lost. This Re number of transition is called critical Reynolds number (ReCr), and it depends on each case conditions, geometry, boundaries, etc. Some examples of approximate critical Reynolds number values are the following: •Flow around a sphere: ReCr = 300000 •Flow inside a tube: ReCr = 2300 •Flow over a flat plate: ReCr = 300000 •Flow over an airfoil: ReCr = 500000 A turbulent flow is characterized by its disorder, impressibility and statistical fluctuations of all the flow variables (velocity, pressure, density, temperature, etc.) around mean values. Laminar flows can be accurately computed only with the Navier-Stokes equations system and a constitutive law defining the fluid nature, without any additional information, but unfortunately, this is not the case of turbulent flow. The equations that govern a turbulent flow are non-lineal, so it can just be solved analytically in a few cases. Nowadays, with the increasing computer power in speed and memory, it is becoming easier to solve them numerically with CFD techniques. This method is called Direct Numerical Simulation (DNS). But the accurate numerical description of the fluctuations of a turbulent flow is still out of reach, specially at high Reynolds numbers, because the size of the smallest turbulent eddies is inversely proportional Pau Guilleumes Mayoral R - 37 7.2 Turbulence to Re3/4, as the Kolmogorov scale related to the dissipation of turbulence states. For getting a resolution of npoints per unit length on the smallest eddy, the mesh points required are n3×Re9/4. But it is even more complicated than that, since the Navier-Stokes equations needs to be integrated in time for transient flows, with a time step determined by the smallest turbulent time scales, which keep a proportionality to Re3/4. To sum up, the total calculations to be made are proportional to Re3. This is the case for homogeneous turbulence, but if wall flows and other cases which have inhomogeneous characteristics have to be computed, the computational cost is even higher, because the mesh has to adapt its resolution near the wall. For this reason it is essential to use some approximations that enable to run the simulations and get accurate results in acceptable CPU times. From higher to lower level of approximation, there are the following models [16] 1. Large Eddy Simulation (LES) 2. Reynolds Averaged Navier-Stokes (RANS) 3. Thin Shear Layer Approximation 4. Parabolic Approximations 5. Boundary Layer Approximation 6. Distributed Loss Model 7. Viscous-inviscid interaction models 8. Time-dependant Euler equations 9. Potential flow model The Hierarchy of the different models and their degree of approximation is summarized in figure 7.1. Pau Guilleumes Mayoral R - 38 7.2 Turbulence Figure 7.1: Hierarchy of the different dynamical levels of approximation from Hirsch, C. [16] 7.2.1 Boussinesq hypothesis Most of the turbulence models are based upon the Boussinesq hypothesis: •The turbulence decays unless there is shear in isothermal incompressible flows (this phenomena was experimentally observed) •Turbulence increases as the mean rate of deformation increases Pau Guilleumes Mayoral R - 39 7.3 The Coanda Effect ~ ξ=~ ∇ × ~ν = 0 −→ ~ν =~ ∇φ(7.25) Using the potential flow approximation, the energy equation is no longer independent, but is determined by the initial boundary conditions and the function φ. The basic potential equation in conservation form is: ∂ρ ∂t +~ ∇ · (ρ~ ∇φ)=0 (7.26) 7.3 The Coanda Effect The Coanda effect is the phenomena in which a flow is attached to a wall or walls placed around it and remains attached even the surface curves away from the initial jet direction. This effect was first reported by Thomas Young in 1800, and many investigations have been made since then. Wall attachment has been successfully and effectively used in fluid amplifiers, combustion, sizing of particles, air conditioning and so on [19]. The phenomena as we know it nowadays, in which all contemporary studies on the field are based was later discovered and patented by Henri Marie Coanda, a Romanian aeronautical engineer. He designed and built, in 1910, the first jet-propelled aircraft, with a rotary compressor powered by a 4-cylinder piston engine. After performing the first flight which unfortunately ended in an accident, he noticed that the flames and exhausted gases from the engine "hugged" the fuselage (so the aircraft side rapidly caught fire). After 20 years of studies, the phenomenon was recognized as a new aerodynamic effect: the Coanda effect. Nowadays, the Coanda Effect is used in many devices, but one of the most significant examples is the NOTARR (No tail rotor) helicopter, that uses a fan with adjustable blades in the tail-boom to get a high volume of low-pressure air. This air creates a boundary layer coat using the Coanda effect when exiting through two designed slots in the tail, and provides anti-torque control for the helicopter. Pau Guilleumes Mayoral R - 46 7.3 The Coanda Effect Figure 7.4: NOTAR R system sketch by MD Helicopters [18] 7.3.1 Mechanism of Coanda Effect The mechanism of the Coanda effect can be qualitatively described with figure 7.5. In figure 7.5a), a bubbling jet that is generated vertically upwards through a single nozzle, rises through the surrounding liquid and spreads horizontally. As there is no wall or another jet next to it, the pressure around it is uniform at any vertical position. In this case, the bubbling jet ascends vertically upwards. If there is a vertical wall next to the jet (figure 7.5b), the pressure of the fluid between the wall and the jet decreases as the outer edge of the jet approaches the wall. The consequence of this pressure difference pulls the jet towards the wall so that it becomes attached. If instead of a wall, there is another vertical jet next to the first one, a very similar phenomenon occurs, as shown in figure 7.5c). Pau Guilleumes Mayoral R - 47 7.4 CFD Figure 7.5: Explanation of the Coanda Effect from Iguchi, M. et al. [19] 7.4 CFD Computational fluid dynamics (CFD) provide cost-effective means of real flows simulation, by using the numerical solution of the governing equations (also known as Navier-Stokes equations when talking about Newtonian fluid dynamics). When working in a turbulent problem, they are mostly applied in reduced forms, which are still in development, to save computational effort. Since the 1950’s, the computing power and memory has increased significantly, allowing CFD techniques to arise as an great alternative way of testing fluid flow systems, validating the results with experimental and theoretical data. It can also allow to analyse systems whose conditions are not possible or extremely difficult to test empirically, and are not amenable to find any analytic solution. Nowadays, there are several CFD commercial packages in the market such as ANSYS FluentR , OpenFOAMR , CalculiXR , AVL FIRER , and many others, Pau Guilleumes Mayoral R - 48 7.4 CFD some of them being of public domain. 7.4.1 CFD design cycle The design cycle of a CFD analysis follows some clear steps that have to be identified: 1. Problem statement: the problem to be solved needs to bee stated, defined and understood by whoever is willing to run the analysis. Without a proper comprehension of the problem, the analysis can not be done with guarantees of success. 2. Mathematical model definition and validation: as it has been said before, there are plenty of mathematical approaches with different methods, each one of them being appropriate for certain type of calculations, and with a different level of approximation. If the problem has been understood, the optimal mathematical model can be implemented. 3. Mesh generation: a virtual 2D or 3D model of the case (depending on the approach) has to be introduced, in order to generate the mesh that will define the elements in which the mathematical model will be applied 4. Space discretization: the space discretization will be further explained in section 7.4.2. 5. Time discretization: the time discretization will be further explained in section 7.4.3. 6. Iterative solver: the iteration stability and accuracy parameters have to be established. 7. CFD software: all the previous data, mathematical models, and defined parameters, have to be implemented in the CFD software to be used. It may have a user friendly interface, or maybe the code would need to be modified directly. The most appropriate time integration and resolution methods (including convergence acceleration techniques) have to be selected. 8. Simulation run: the hardware runs the simulation under the CFD implemented parameters. It can be ran in a single computer CPU, in parallel between the different cores of a single computer or in parallel between the different computers of a cluster. 9. Graphic post-processing: Once the results have been acquitted, they have to be inspected and its format modified in order to emphasize the important parts of the analysis, and make them understandable and interpretable. A visualization software is used for this purpose. 10. Verification of the results: they have to be analysed and compared with other CFD analysis, empirical and analytical results . Pau Guilleumes Mayoral R - 49 7.4 CFD It is important not to mistake Verification and Validation: •Verification: look for errors in the model implementation. The question that should be asked while verifying is: Are we solving the equations right? •Validation: check if the model is adequate.The question that should be asked while validating is: Are we solving the right equations? 7.4.2 Space discretization Once the mathematical model is selected, the discretization process has to be done. This process is about translating the geometrical and mathematical models into numbers, so that the computer can understand it in order to run the simulation. The first parameter to be discretized is the space. This includes the empty spaces where the flow runs, but also the geometries and solid bodies present in the field, even those that enclose the domain. The numerical methods convert the continuous differential equations to a system that enables to find the solution at discrete points in space, called grid points. Or, what is the same, the continuous information contained in the differential equation is replaced with discrete values, To begin with, the solid surfaces in the domain are available from a CAD system in a suitable digital form (such as the .stl format). Around them, a set of points is distributed in the flow domain and on the solid surfaces creating the grid, also called mesh. Instead of the continuity of the real space, there is a finite number of isolated points. The numerical approximation depends on the mesh size. The closer the points are between each other, a better discretization of the continuum flow field is reached. This is a major step in the whole process, since for complex geometries the solution will be also dependant on the form of the mesh. This step is even more significant in three-dimensional CFD simulations. There is two different types of grids or meshes: structured and unstructured. In the structured meshes, formed by n families of lines (for a n-dimension space), the points are placed at the intersection of a line of each family. The unstructured grids have an arbitrary mesh point distribution, linked through polynomials (in 2D) or polyhedrals (in 3D). The accuracy of the obtained numerical results is critically dependent on mesh quality [16]. Once the mesh is available, the second part of the discretization process can be started. It consists on the discretization of the mathematical model equations. All mathematical Pau Guilleumes Mayoral R - 50 7.4 CFD operators have to be transformed into arithmetic operations on the mesh point values [16]. The result is a set of algebraic relations between adjacent points in the mesh, called numerical scheme. It is very important the choice between a steady or unsteady model for the flow equations when defining the algorithm, but in this case, there is no alternative to the use of a time-dependant mathematical model, since we are dealing with a problem with a transient flow behaviour. There are different methods to perform the conversion from derivatives to arithmetic operations.The methods that are more widely used are: •Finite Difference Method •Finite Element Method •Finite Volume Method. 7.4.2.1 The Finite Difference Method The Finite Difference Method is the simplest method to apply. It requires high degree of mesh regularity, so it has to be set in a very structured way. It consists on approximating the derivatives of the differential equations using truncated Taylor series. According its theoretical definition, the derivative at point xis defined by: ux=∂u ∂x = lim ∆x→0 u(x+ ∆x)−u(x) ∆x(7.27) Removing the limit, the finite difference is obtained. If ∆xis small but finite, the finite difference is an approximation, which will be improved by reducing ∆x, but as long as it is finite, there will be an error called truncation error. The order of accuracy of the difference approximation will be related to the power of ∆xwith which this error trends to zero. Pau Guilleumes Mayoral R - 51 7.4 CFD Figure 7.6: Taylor expansion of (e√x−1) up to order 5 from Hirsch, C. [16] Figure 7.7: Finite difference discretization method from Sayma, A.[17] For grid point 2 in the middle between points 1 and 3 (figure 7.7), the Taylor series expansion gives the value of the variable at point 1 as a function of the variable at point 2 and its derivatives 7.28, or the analogous expression of variable at point 3, depending of point 2 variables and its derivatives 7.29: θ1=θ2−∆x ∂θ ∂x!2 +1 2(∆x)2 ∂2θ ∂x2!−....... +1 n(∆x)n ∂nθ ∂xn!−....... (7.28) Pau Guilleumes Mayoral R - 52 7.4 CFD θ3=θ2+ ∆x ∂θ ∂x!2 +1 2(∆x)2 ∂2θ ∂x2!−....... +1 n(∆x)n ∂nθ ∂xn!−....... (7.29) If the Taylor series is truncated after the second term and rearranged, the expression 7.30 for the first derivative at point 2 is obtained, and it is called first order backward difference approximation of the first derivative. The truncated terms are associated to the truncation error. ∂θ ∂x!2 =θ2−θ1 2∆x(7.30) Subtracting equation 7.28 from 7.29, a second order central difference approximation for the first derivative is obtained: ∂θ ∂x!2 =θ3−θ1 2∆x(7.31) Finally, adding 7.30 and 7.29, the second derivative at point 2 is obtained: ∂2θ ∂x2!2 =θ1−2θ2+θ3 (∆x)2(7.32) If the expression for the approximate derivatives are replaced into a differential equation, the finite difference equation is obtained. Hence, at point 2, the differential equation is transformed into an algebraic equation. The process must be repeated for all the points. At the end points, the known values of the boundary conditions are set, so the system can be solved. 7.4.2.2 The Finite Element Method The Finite Element Method was developed between 1940 and 1960, in order to be applied mostly in structural dynamic problems, even though it was later extended to the fluid flow field. It is based on the "Method of Weighted Residuals", a powerful partial differential equations solver. The main advantage of this method over the Finite Difference Method is that it can be easily applied for complex geometries, using irregular grids of various shapes. Moreover, its functions give the variation of the differential equations not only at grid points, but also between them. Its mathematical formulation is the following: Pau Guilleumes Mayoral R - 53 7.4 CFD Assuming the general differential equation 7.33, only for presentation purposes (the method can be applied for any other differential equation) Q(T)=0 (7.33) By seeking an approximate solution T0using some trial function, if we substitute this into the differential equation, it will not satisfy the equation, thus a residual appears on the right hand side: Q(T0) = R(7.34) Then, a weighting function W is introduced, so that the integral over the weighted residual vanishes over the whole domain: ZΩWQ(T0)dΩ = 0 (7.35) It is assumed that the trial functions are polynomial with a number of unknown coefficients, so that the solution of the differential equation can be obtained after computing those coefficients by solving the system of the integrated trial functions. There are several methods which purpose is to define the trial and weighting functions. Some of them are: •Sub-Domain Method •Collocation Method •Least-Square Method •Galerkin Method This last technique called Galerkin Method is the most widely used, and it will be further explained. First of all, local trial functions have to be assumed over the domain, discretized by subdividing it into non-overlapping cells called elements or sub-regions. They can present a variety of shapes such as triangles or quadrilaterals in two dimensions, and hexahedral, pentahedral or prisms in three dimensions. The trial functions are interpolation functions which assume the shape of the variation of the variable to compute between the grid points comprising the cell [17]. The simplest trial functions are the linear shape functions, which assume that the variable has a linear variation between grid points. The solution can be expressed as: T0(x) = TiNi(x)(7.36) Pau Guilleumes Mayoral R - 54 7.4 CFD where Tiis the sought solution and Niis the interpolation function, both evaluated at node i. Then, the weighting functions must be chosen. They have a value of Wiat node iand zero elsewhere for each node in the domain. The discrete weighted residual form expression is the following: ZΩWiQ(TiNi(x)) dΩ = 0 (7.37) If all the domain cells are integrated, a system of algebraic equations is created: K·Ti=r(7.38) It can be solved for the coefficients Tithat represent the field function at the nodal points. Krepresent the Jacobean or Mass matrix, and the right hand side rusually contains boundary conditions and source terms. Another way to represent the final system of equations in matrix notation is: [K]{U}={f}(7.39) [K]is obtained by assembling the mass matrix of each individual element [K]e, and the same happens with {f}. A typical form of those parameters may be: [K]e=A  1−1 −1 1  (7.40) considering Athe geometric and/or physical parameters of the element, and {f}e=  qi qj (7.41) 7.4.2.3 The Finite Volume Method The Finite Volume Method was developed in the 1970’s, and can be considered as a variation of the Weighted Residual Method used in the Finite Element Method of discretization, where the weighting function is 1. It is currently the most used method in CFD, and can be applied in both structured and unstructured grids. It consists on discretizing directly in the physical space the integral formulation of the conservation laws, instead of the differential form, as Pau Guilleumes Mayoral R - 55 7.4 CFD With the Gauss-Seidel method, a higher convergence rate can be obtained since the influence of a perturbation on Unis rapidly transmitted. On the other hand, with the Jacobi method, a perturbation of Un+1 i−1,j will be felt on Ui,j after the whole mesh is swept. Moreover, the new value can be stored in the same location than the old value by overwriting it, as it will not be needed anymore. Therefore only one solution vector has to be stored. Both Jacobi and Gauss-Seidel methods, even though the second one is much faster than the first one, will converge if the matrix A is diagonally dominant. 7.4.4.2 Overrelaxation methods Overrelaxation methods are used to increase the convergence rate of an iterative methods. They consist on the propagation of the corrections (∆Un=Un+1 −Un) faster through the grid. If Un+1 is the value obtained from the basic iterative scheme, the value introduced at the next iterative level Un+1 can be: Un+1 =ωUn+1 + (1 −ω)Un(7.58) or, alternatively, ∆Un=Un+1 −Un∆Un=ω∆Un(7.59) with ∆Un=ω∆Un(7.60) where ωis the overrelaxation coefficient. A considerable gain can be achieved if the overrelaxation coefficient is appropriately optimized for maximum convergence rate. 7.4.4.3 Multigrid methods Multigrid acceleration methods are the most efficient and general iterative techniques known so far. They can be applied to linear and non-linear systems. They work with a sequence of grids, where each grid has approximately twice the number of grid points from the previous grid, so that the final grid is the finest, and the solution is sought there. For example, considering a number of grids from 1 to M where M is the finest, the solution of the system is: Pau Guilleumes Mayoral R - 62 7.4 CFD AMUM=bM(7.61) The approximation to the solution UMrequired by the iterative method is provided by the solution of the previous coarser grid UM−1, and so on. In other words, the solution of any grid UMis considered a good approximation of the solution on the next finer grid UM+1, so that it will reduce the convergence time and computational effort. 7.4.5 OpenFOAMR  OpenFOAMR (Field Operation And Manipulation) [27] is an open source software for computational fluid dynamics (CFD). It was created in 1989 by Henry Weller under the name "FOAM", although it was released open source much later (2004) with the current name, under the conditions of GNU General Public Licence, as it is right now after many years. It consists on a C++ toolbox for the development of customized numerical solvers and pre-/post-processing utilities. Regarding the pre-processing utilities, OpenFOAMR offers a variety of features related to the meshing process such as snappyHexMesh, for the mesh generation for complex geometries, or blockMesh for simple geometries, apart from various mesh conversion and manipulation tools. OpenFOAMR has an extensive list of solvers in order to simulate all kinds of flows, each one of them designed for a specific type of problem. Moreover, there are several models related to various physical properties of the flow. In the first place, there are the thermophysical models, that are concerned with energy, heat and physical properties, so they must be used when the thermal energy, the compressibility or the mass transfer is an important factor. There are also different transport models, comprising the Newtonian, the Bird-Carreau or the Cross Power Law models among many others. And finally, two different methods can be used for the turbulence modelling (if the flow has not been defined as "laminar"): •Reynolds-Averaged Simulation (RAS) •Large-Eddy Simulation (LES) and Detached-Eddy Simulation (DES, DDES, etc) Both of them can be applied in either incompressible and compressible flows, and include a variety of different models. The RAS models for compressible flows are the following: Pau Guilleumes Mayoral R - 63 7.4 CFD •LRR: Launder, Reece and Rodi Reynolds-stress turbulence model for incompressible and compressible flows. •LaunderSharmaKE: Launder and Sharma low-Reynolds k-epsilon turbulence model for incompressible and compressible and combusting flows including rapid distortion theory (RDT) based compression term. •RNGkEpsilon: Renormalization group k-epsilon turbulence model for incompressible and compressible flows. •SSG: Speziale, Sarkar and Gatski Reynolds-stress turbulence model for incompressible and compressible flows. •SpalartAllmaras: Spalart-Allmaras one-eqn mixing-length model for incompressible and compressible external flows. •buoyantKEpsilon: Additional buoyancy generation/dissipation term applied to the k and epsilon equations of the standard k-epsilon model. •kEpsilon: Standard k-epsilon turbulence model for incompressible and compressible flows including rapid distortion theory (RDT) based compression term. •kOmega: Standard high Reynolds-number k-omega turbulence model for incompressible and compressible flows. •kOmegaSSTSAS: Scale-adaptive URAS model based on the k-omega-SST RAS model. •realizableKE: Realizable k-epsilon turbulence model for incompressible and compressible flows. •v2f: Lien and Kalitzin’s v2-f turbulence model for incompressible and compressible flows, with a limit imposed on the turbulent viscosity given by Davidson et al. The available LES and DES models for compressible flows are the following: •DeardorffDiffStress: Differential SGS Stress Equation Model for incompressible and compressible flows •Smagorinsky: The Smagorinsky SGS model. •SpalartAllmarasDDES: SpalartAllmaras DDES turbulence model for incompressible and compressible flows Pau Guilleumes Mayoral R - 64 7.4 CFD •SpalartAllmarasDES: SpalartAllmarasDES DES turbulence model for incompressible and compressible flows •SpalartAllmarasIDDES: SpalartAllmaras IDDES turbulence model for incompressible and compressible flows •WALE: The Wall-adapting local eddy-viscosity (WALE) SGS model. •dynamicKEqn: Dynamic one equation eddy-viscosity model •dynamicLagrangian: Dynamic SGS model with Lagrangian averaging •kEqn: One equation eddy-viscosity model •kOmegaSSTDES: Implementation of the k-omega-SST-DES turbulence model for incompressible and compressible flows. Moreover, OpenFOAMR also offers a wide range of wall function models can be applied as boundary conditions on individual patches, so different wall functions can be applied to different wall regions. The turbulence methods used in the simulations of the fluidic oscillator will be later discussed on the Simulation parameters section 10.1. OpenFOAMR is also supplied with different post-processing utilities. On the one hand, it has a GUI (graphical user interface) called paraView used by the paraFoam utility. It also has a CLI (command line interface) which enables the user to have a conventional data processing activity after the simulation has run (post-processing), or a run-time processing, where the data processing is performed during the running of a simulation. Moreover, it has a set of functions for data sampling and monitoring, and it is able to convert the data into other formats for third-party post-processing tools. Pau Guilleumes Mayoral R - 65 Section 8: Problem approach 8 Problem approach This study will focus its attention on the double feedback loop bi-stable fluidic oscillators. 8.1 Oscillator characteristics Regarding their geometry, they can present a wide range of variable dimensions, depending on various factors such has the flow regime (laminar or turbulent), the purpose of the actuator and the use that is given to it, but also its integration with the full system. Its different parts are: a)Inlet nozzle: It consists on the longest channel of the device, due to the necessity of the incoming flow to be as longitudinal as possible, to not to alter the mixing chamber flow. Moreover, it determines the mixing chamber inlet flow conditions. b)Mixing chamber: Where the crucial phenomena that determines the outlet flow and the oscillator characteristics take place. The working principle of the fluidic oscillator is based on the formation of zones of different pressure on both sides of the jet inside the mixing chamber that control the direction of the flow. c)Inner blocks: The end of the inner blocks is a sharp edge, which angle and amplitude of the throat between both of them have a deep impact on the turbulence inside the mixing chamber. d)Feedback channels: Connect the inlet and outlet of the mixing chamber. When the flow collides with the outlet throat walls of the mixing chamber, part of the flow is redirected upstream through the feedback channels, and influences the incoming flow from the inlet channel. e)Outlet: The flow that passes through the outlet throat reaches the outlet, where a splitter plate divides it in two channels. If it was in laminar regime, the flow would be divided and each half would go throughout both channels, but as the oscillator works under turbulent conditions, an oscillating flow between both channels is created. After the bifurcation, the channels get thinner and the flow speed is increased to adapt it to the outlet conditions. f)Recirculation bubble: Created with the interaction of the main flow and perpendicular flow coming from the control port (in the case of study, the feedback channel. As Pau Guilleumes Mayoral R - 66 8.1 Oscillator characteristics more fluid is injected from the feedback channel, the bubble size increases and extends downstream while unattaching the flow from the wall of the mixing chamber. Figure 8.1: Bi-stable fluidic oscillator flow regions scheme from Ruiz, M. [2] 8.1.1 Stages of the oscillator At the beginning, the flow is randomly attached to the upper or the lower wall of the mixing chamber, next to the inner block. It has been considered, for this particular explanation, that the process begins in the lower wall: In the first stage, φ= 0◦(figure 8.2), the jet is attached to the lower wall of the mixing chamber. It partially collides with the outlet throat lower wedge before exiting through the upper outlet channel, generating some vorticity in the outlet, and a recirculating flow in the lower feedback channel, that starts to pump the recirculating bubble between the main flow and the lower wall. In the stage where φ= 60◦(figure 8.3), the jet recirculating bubble begins to grow, fed by the perpendicular flow coming from the lower feedback channel. It unattaches the main flow from the inner block, and pushes it to the upper side of the oscillator, while colliding entirely against the outlet throat, that redirects it to the upper outlet channel. Then, in φ= 120◦(figure 8.4), the lower recirculating bubble, still being fed by the perpendicular flow, has grown enough to attach the main flow to the upper side. The jet passes through the throat with almost any losses, and exits through the upper outlet channel, although it is about to be split by the plate. Pau Guilleumes Mayoral R - 67 8.1 Oscillator characteristics Finally, the phase φ= 180◦(figure 8.5) is the symmetric stage of φ= 0◦. The jet is attached to the upper wall of the mixing chamber because the lower recirculating bubble has reached its maximum. The upper recirculation flow begins to form, creating the consequent recirculating bubble. The main flow starts to collide with the upper part of the outlet throat and exits the device through the lower outlet channel, even though there is some vorticity in front of the splitter plate in the outlet. Figure 8.2: CFD simulation results of the flow in a fluidic oscillator, phase φ= 0◦from Krüger, O.[20] Figure 8.3: CFD simulation results of the flow in a fluidic oscillator, phase φ= 90◦from Krüger, O. [20] Figure 8.4: CFD simulation results of the flow in a fluidic oscillator, phase φ= 180◦from Krüger, O. [20] Pau Guilleumes Mayoral R - 68 8.2 Turbulence model Figure 8.5: CFD simulation results of the flow in a fluidic oscillator, phase φ= 270◦from Krüger, O. [20] As any oscillatory fluid-flow phenomena with fixed-geometry boundaries, fluidic oscillators are governed by the Strouhal number, defined as: St =fb w(8.1) where: •f(Hz): frequency of the oscillations or vortex shedding •b(m): width of the inlet nozzle throat •w(m/s): bulk velocity in the exit of the inlet nozzle For large Strouhal numbers (order of 1) the viscosity dominates the fluid flow resulting in a collective oscillating movement of the fluid, whereas for low Strouhal numbers (St << 1) the flow can be considered as quasi-steady and high speeds dominate the flow oscillations. At intermediate Strouhal numbers, the oscillations are characterized by quick build up and subsequent shedding of vortices. The results will be presented as the variation of the Strouhal number with the Reynolds number. 8.2 Turbulence model The turbulent model used by the solver in this study correspond to one of those that have been more accurate in previous studies related to numerical analysis of fluidic oscillators [1] [28] [2] (among others). In this case, the fluidic oscillator will be analysed according the k−ωSST approach. Pau Guilleumes Mayoral R - 69 8.3 Experiment conditions The k−ωShear Stress Transport turbulence model is a two-equations eddy-viscosity model developed by Menter in 1993 [29], which combines the k−ωand the k−εmodels. It presents a gradual transition from the standard k−ωmodel in the inner region of the boundary layer, to a version of the k−εmodel applied to high Reynolds number in the outer part of the boundary layer. Whereas the k−ωmodel links turbulence kinetic energy kwith the specific dissipation ω, the k−εmodel links turbulence kinetic energy kwith the dissipation velocity ε. Both of them provide the solver with two extra equations that give the needed parameters to compute the dynamic viscosity, necessary for the Navier-Stokes equations. It contains a modified formulation for the turbulent viscosity, focused on the transport effects of the turbulent shear stress: νT=a1k max(a1ω, SF2)(8.2) instead of: νT=k/ω (8.3) as in the Wilcox’s standard k−ωmodel. Further explanation of the turbulent model formulation can be found in [29]. 8.3 Experiment conditions A standard ambient temperature and pressure (SATP) environment is set for the simulations, with a temperature of 25 oC or 298.15 K and an absolute pressure value of 100kPa (1 bar). The inlet velocity parameter is crucial in this study. As the compressible effects on the flow are intended to be studied, the velocity value has to be high enough, but in the other hand, if it is too high, the flow becomes trans-sonic, so the results and the implemented parameters would no longer be valid. The base inlet velocity is set to M= 0.5. Following the next equation, the resultant value in m/s is 173.034 m/s. U=M∆c=MsγRT M(8.4) Pau Guilleumes Mayoral R - 70 8.3 Experiment conditions where γ= 1.4for air, R= 8.314510 J mol∆K(universal gas constant) and the molecular mass of the gas M= 0.028964kg/mol. Further simulations with a variation on the inlet velocity value will be carried on, either to seek a numerically stable solution of the computations in the event of divergence, and to expand the knowledge of the turbulence phenomena inside the fluidic oscillator. The range of tested inlet velocities will be always high enough to feel the compressible effects, but low enough to stay outside the trans-sonic zone. Pau Guilleumes Mayoral R - 71 10.1 Simulation parameters and implementation Regarding the thermodynamic parameters, the model chosen is hConst, which assumes a constant Cpand a heat of fusion Hf. •Cp= 1004.8 •Hf= 2.544e+ 06 The form of energy to be used in the solution is the enthalpy (sensibleEnthalpy), and the equation of state of the fluid correspond to the perfect gas equation: ρ=1 RT p(10.2) The transport properties of the fluid are included in the thermophysical properties dictionary, so it is not necessary to add an specific dictionary as it is with solvers that do not include energy or heat libraries. In this case, a constant (const) transport model has been selected, which assumes a constant µand Prandtl number Pr =Cpµ/κ. The values for those constant variables are: •µ= 1.83632e−05kg/ms •Pr = 0.7 10.1.1.2 Turbulence properties As it has been explained, the turbulence model analysed in this study is the RAS kOmegaSST. For the extra required parameters, the default values are used. 10.1.2 Initial conditions The initial conditions are specified in the directory of the first time step evaluated by the solver. As it has been set up the startTime as 0, the files related to those initial conditions are placed in the 0 directory. The required parameters for the RAS k-ωSST calculations are the following: U,T,p,k, ω,αt,νt. Pau Guilleumes Mayoral R - 78 10.1 Simulation parameters and implementation 10.1.2.1 U The file U correspond to the fluid velocity at the various boundaries. It is set to 0 in all of them except for the inlet, where it takes the value of 173.034 m/s (the necessary velocity to reach M= 0.5at the experiment temperature conditions). 10.1.2.2 T The temperature is set to 298 K at all the boundaries and the internal field. 10.1.2.3 p The initial and boundary values of the pressure is 105pa (or kg m∆s). It is important to notice that this OpenFOAMR does not work with reduced pressure values (p/ρ). 10.1.2.4 k krepresents the turbulent kinetic energy of the fluid. It can be initially approximated with the following expression: k= 3/2(UI)2= 71.858m2/s2(10.3) where Uis the fluid reference velocity and I the turbulence intensity, defined as the ratio of the root-mean-square of the velocity fluctuations with appropriate values between 1 I= 0.16Re−1 8 Dh= 0.04 (10.4) ReDhis the Reynolds number applied to the hydraulic diameter: ReDh=UDh ν= 55281.57 (10.5) where Dh= 4,952mm,U= 173.034m/s and the kinematic viscosity at 298 K is ν=µ ρ= 1.55 ×10−5 10.1.2.5 ω ωis the specific turbulent dissipation rate. It is an essential parameter for the k-ωturbulent model. It can be estimated as: Pau Guilleumes Mayoral R - 79 10.1 Simulation parameters and implementation ω=k1/2 Cµl= 446259.9s−1(10.6) 10.1.2.6 αt αtrepresents turbulent thermal diffusivity. It plays a very important role in the wall functions of the boundary conditions, and the turbulent heat flux modelling. Its dimensions are kg/ms. 10.1.2.7 νt νt(νt=m2/s) represents the kinematic variable of the eddy viscosity, also called turbulent viscosity (νt=µt/ρ). It comes from the Boussinesq assumption that states that the momentum transfer caused by turbulent eddies can be modelled with an eddy viscosity 7.2.1. 10.1.3 System parameters The system directory contains the corresponding files for setting the parameters associated with the solution procedure. 10.1.3.1 controlDict The controlDict dictionary contains the essential input parameters for the creation of the database that controls the input and output of the case. First of all, the solver application must be defined. In this case, rhoPimpleFoam (a transient solver for turbulent flow of compressible fluids for HVAC -Heating, ventilation and air conditioning- and similar applications). The time control is one of the most important parameters. It controls the start and end time of the simulation, as well as the time step (∆t). Then it comes the Data writing controls, that enables the user to set the timing and format of the output files writing among other parameters, and the graph controls for plotting the solution. Pau Guilleumes Mayoral R - 80 10.1 Simulation parameters and implementation Additional libraries and functions can be added to the simulation in the controlDict dictionary, such as the probes function that writes out the values of each time step of the specified fields (p and U in this case) in some specific previously defined points of the domain, displayed in table 10.1. Probe Coordinates (m) Location x y z 1 0.087 0.007125 0.001625 exit of the upper outlet channel 2 0.087 - 0.007125 0.001625 exit of the lower outlet channel 3 0.0585 0.01 0.001625 middle of the upper feedback channel 4 0.0585 - 0.01 0.001625 middle of the lower feedback channel 5 0.0504 0.00185 0.001625 upper side of the mixing chamber 6 0.0504 - 0.00185 0.001625 lower side of the mixing chamber 7 0.0665 0.0048 0.001625 inlet of the upper feedback channel 8 0.0665 - 0.0048 0.001625 inlet of the lower feedback channel Table 10.1: Location of the probes 10.1.3.2 fvSchemes The fvSchemes file contains the specification of which numerical discretisation schemes are used by the solver. It can be selected at run-time, or what is the same, it can be modified without being necessary to restart the simulation. The used schemes for the RAS simulation are displayed in table 10.2: Schemes methods ddtSchemes Euler gradSchemes Gauss linear divSchemes Gauss linear or Gauss limitedLinear 1 laplacianSchemes Gauss linear orthogonal interpolationSchemes linear snGradSchemes orthogonal wallDist method meshWave Table 10.2: Schemes used for the RAS K-ωSST simulation Pau Guilleumes Mayoral R - 81 10.1 Simulation parameters and implementation 10.1.3.3 fvSolution In the fvSolution file, the user can control the equation solvers, tolerances and algorithms. The first sub-dictionary is solvers. It specifies each linear-solver that is used for each discretised equation. The solver can be: •PCG/PBiCG: p reconditioned (bi-)conjugate gradient, with PCG for symmetric matrices, PBiCG for asymmetric matrices. •smoothSolver: solver that uses a smoother. •GAMG: generalised geometric-algebraic multi-grid. •diagonal: diagonal solver for explicit systems. Some of the solvers use a smoother, and it has to be specified which one among all the available smoothers is going to be used: •GaussSeidel •symGaussSeidel •DIC/DILU •DICGaussSeidel The solver has some other parameters that have to be taken into account. First of all, the tolerance and relTol (relative tolerance), force the solver to stop if the residual falls below the tolerance value or if the ratio of current to initial residuals falls below the relTol value. Thus, the tolerance represents the level at which the residual is small enough so the solution reaches the desired accuracy. Another parameter of the solver is the preconditioner. Its definition and types can be found at Hirsch, C. "Numerical Computation of Internal and External Flows: The Fundamentals of Computational Fluid Dynamics" [16]. Moreover, if a relaxation factor is to be used in some of the solvers, it has to be introduced in the fvSolution dictionary. Finally, a very important choice has to be made: the algorithm. There is three types of algorithms. •PISO: (pressure-implicit split-operator) Pau Guilleumes Mayoral R - 82 10.2 Variations on the simulation parameters •SIMPLE: (semi-implicit method for pressure-linked equations) •PIMPLE: (PISO and SIMPLE combined algorithm) PISO and PIMPLE are used for transient problems, whereas SIMPLE is used for steady-state. The used algorithm for the RAS k-ωSST simulation is PISO, while for the LES-RAS Spalart-Allmaras DDES simulation, the selected algorithm is PIMPLE. Whatever the selected algorithm is, some additional parameters need to be introduced, such as nCorrectors,nNonOrthogonalCorrectors,nOuterCorrectors or momentumPredictor. All of those parameters are set in their default values. 10.1.3.4 decomposeParDict This dictionary is aimed to decompose the case to analyse in several separated parts, to be able to run it in parallel using various processors (or machines, if working in a local network). 10.2 Variations on the simulation parameters In order to achieve a better convergence of the calculations, the different variations on the simulation parameters were done are the following: •Originally, the time step (∆t) was not dynamic. It was set to 1.0e-6 s. To solve the floating point error, it must be reduced. For this reason, after setting the appropriate maximum Courant number, it was defined as dynamic, were its value is automatically calculated by the solver itself. •Increment of the residuals tolerance: During the first simulations, the solver crashed several times after approximately 800 time steps. The tolerance in all the residuals was then set to 1.0e-04, instead of the default values of 1.0e-06 and 1.0e-05. •Since the rhoPimpleFoam solver was not able to compute under compressible supersonic flow conditions (the flow gets supersonic inside the fluidic oscillator due to its geometry, mainly at the inlet nozzle), the first solution that was sought was to reduce the velocity inlet value. Moreover, some research was done on the compressible supersonic solver sonicFoam. Further explanation of this velocity reduction process is given in section 11. •Other minor parameters were changed in order to optimize them for the calculations. Pau Guilleumes Mayoral R - 83 Section 11: Results 11 Results In this section, a detailed report of the obtained results of the simulation is given. The initial simulation (with an inlet Mach value of 0.50) crashed several times approximately at the time t = 0.0001725 s, as the maximum number of iterations was exceeded. After checking the results obtained so far it was clear what the problem was: the velocity values near the inner throat had reached supersonic values due to the convergent nozzle of the inlet, and the solver in use was not designed to compute under those conditions. In figure 11.1 the Mach values of the internal field are shown: Figure 11.1: Mach values of the initial simulation internal field The pressure field of figure 11.2 shows a very low pressure zone in the area where the highest Mach values are reached. Moreover, as a consequence of the supersonic flow, some pressure waves appear in the exit throat, and they propagate backwards blocking the entrance of the feedback channels. Pau Guilleumes Mayoral R - 84 Section 11: Results Figure 11.2: Pressure values of the initial simulation internal field In order to face this problem and carry on with the simulation (not even a single oscillation had been simulated yet), two possible solutions were presented. On the one hand, the inlet velocity value had to be reduced to the point where all the internal flow field velocity could be treated as subsonic. On the other hand, further research of the OpenFOAMR solvers had to be made, to start working with a solver which enables the calculation of supersonic flows. Reducing the inlet velocity value also reduces the maximum Mach value in the internal field. Table 11.1 shows the maximum values of the velocity for each simulation while varying the inlet value. Inlet Internal field Simulation Mach U [m/s] Re Max. Mach Last ts Last written ts Ending status 0.50 173.034 55281.57 2.529 0.000172445 0.00017219 divereged 0.45 155.73 49753.223 1.611 0.00023632 0.000236078 aborted 0.40 138.43 44226.152 1.495 0.00022798 0.000223448 aborted 0.35 121.12 38695.886 1.415 0.000236312 0.00023601 aborted 0.30 103.82 33168.81 1.243 0.000281094 0.000275568 divereged 0.25 86.517 27640.786 - - - failed 0.20 69.214 22112.757 1.339 0.000543004 0.00538636 divereged 0.15 51.90 16581.213 1.767 0.00105472 0.00104997 divereged 0.10 34.607 11056.378 1.298 0.000945026 0.000938398 divereged Table 11.1: Inlet and internal field Mach values and simulation parameters The increment of the maximum Mach value reached in the internal field on the M= 0.15 and M= 0.10 simulations despite decreasing the inlet velocity value is probably due to Pau Guilleumes Mayoral R - 85 Section 11: Results reaching a more advanced stage of the simulations. 0 0,0002 0,0004 0,0006 0,0008 Simulation time (s) 90000 1e+05 1,1e+05 1,2e+05 Pressure (Pa) Probe 1 Probe 2 Probe 3 Probe 4 Probe 5 Probe 6 Probe 7 Probe 8 Figure 11.3: Evolution of the pressure field in the probe locations of Mach 0.10 simulation 0,0008 0,00085 0,0009 0,00095 Simulation time (s) 95000 1e+05 1,05e+05 1,1e+05 1,15e+05 1,2e+05 Pressure (Pa) Probe 1 Probe 2 Probe 3 Probe 4 Probe 5 Probe 6 Probe 7 Probe 8 Figure 11.4: Evolution of the pressure field in the probe locations of Mach 0.10 simulation As it can be seen, none of the simulations converged properly, as the internal field velocities kept increasing above sonic values, even though it was significantly reduced on the inlet. In figures 11.3 and 11.4 it is demonstrated that the stationary oscillatory stage is not Pau Guilleumes Mayoral R - 86 Section 11: Results reached, as none of the probes placed in key locations of the oscillator presents a regular oscillation of the field values (i. e. the pressure field), although some of them present evidences of being on the edge of becoming oscillatory. A new strategy was followed afterwards, by increasing the tolerance on the solver solutions during the transient phase, and decreasing it again when the stationary oscillation phase was reached, but the results were not appropriate at all. The high tolerance values induced the obtaining of some false results that progressively mislead to a total failure of the simulation. The previous, initial and final stage of this failure is shown in fig.11.5, 11.6and 11.7. Figure 11.5: Mach values of the internal field of the M=0.10 simulation before failure Figure 11.6: Initial false Mach values of the internal field of the M=0.10 simulation Pau Guilleumes Mayoral R - 87 Section 15: Bibliography [16] C. Hirsch, Numerical Computation of Internal and External Flows: The Fundamentals of Computational Fluid Dynamics. Elsevier Science, 2007. [17] A. Sayma, Computational Fluid Dynamics. Bookboon, 2009. [18] I. MD HELICOPTERS, “Notar technologyR , www.mdhelicopters.com/v2/notar.php,” 2014. [19] M. Iguchi and O. J. Ilegbusi, The Coanda Effect, pp. 41–88. New York, NY: Springer New York, 2011. [20] O. Krüger, “Cfd animation of the flow in a fluidic oscillator, http://fd.tu-berlin.de/en/research/projects/flow-control/fluidics,” 2014. [21] C. J. Campagnuolo and H. C. Lee, “Review of some fluidic oscillators,” tech. rep., Washington DC 20438, USA, Apr. 1969. [22] F. T. Brown, “A combined analytical and experimental approach to the development of fluid-jet amplifiers,” Journal of Basic Engineering, vol. 86, no. 2, 1964. [23] M. Sitter, “Internal flow of fluidic oscillators: A numerical and experimental investigation, master of science thesis,” Dec. 8 2015. [24] P. Gil, “Estudio de un amplificador fluídico mediante 3d-cfd. tfg thesis,” Dec. 28 2015. [25] “Cfd online discussion forums, main forum, url: http://www.cfd-online.com/,” 1998-2016. [26] W. Haase, B. Aupoix, U. Bunge, and D. Schwamborn, FLOMANIA - A European Initiative on Flow Physics Modelling: Results of the European-Union funded project, 2002 - 2004. Notes on Numerical Fluid Mechanics and Multidisciplinary Design, Springer Berlin Heidelberg, 2006. [27] H. G. Weller, G. Tabor, H. Jasak, and C. Fureby, “A tensorial approach to computational continuum mechanics using object-oriented techniques,” Comput. Phys., vol. 12, pp. 620–631, Nov. 1998. [28] S. Raghu, S. A. Gokoglu, M. A. Kuczmarski, and D. e. Culley, “Numerical studies of a supersonic fluidic diverter actuator for flow control, technical report,” tech. rep., Oct. 01 2010. Report/Patent Number: NASA/TM-2010-216805, AIAA Paper 2010-4415, E-17437. [29] F. R. Menter, “Zonal two equation kappa-omega turbulence models for aerodynamic flows,” AIAA Fluid Dynamics Conference, 1993. Pau Guilleumes Mayoral R - 94