A simple and efficient MPPT method for low-power PV cells

Penella López, María Teresa,Gasulla Forner, Manuel

Abstract

Small-size PV cells have been used to power sensor nodes. These devices present limited computing resources and so low complexity methods have been used in order to extract the maximum power from the PV cells. Among them, the fractional open circuit voltage (FOCV) method has been widely proposed, where the maximum power point of the PV cell is estimated from a fraction of its open circuit voltage. Here, we show a generalization of the FOCV method that keeps its inherent simplicity and improves the tracking efficiency. First, a single-diode model for PV cells was used to compute the tracking efficiency versus irradiance. Computations were carried out for different values of the parameters involved in the PV cell model. The proposed approach clearly outperformed the FOCV method, specially at low irradiance, which is significant for powering sensor nodes. Experimental tests performed with a 500mW PV panel agreed with these results.

Full text

Research Article A Simple and Efficient MPPT Method for Low-Power PV Cells Maria Teresa Penella1and Manel Gasulla2 1UrbioticaS.L,ParcUPC,EdificiNexusII,C/JordiGirona29,08034Barcelona,Spain 2Universitat Polit` ecnica de Catalunya, C/Esteve Terradas 7, 08860 Castelldefels, Spain Correspondence should be addressed to Manel Gasulla; [email protected] Received 31 October 2013; Accepted 28 December 2013; Published 27 February 2014 AcademicEditor:IsmailH.Altas Copyright © 2014 M. T. Penella and M. Gasulla. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Small-size PV cells have been used to power sensor nodes. These devices presentlimited computing resources and so low complexity methods have been used in order to extract the maximum power from the PV cells. Among them, the fractional open circuit voltage (FOCV) method has been widely proposed, where the maximum power point of the PV cell is estimated from a fraction of its open circuit voltage. Here, we show a generalization of the FOCV method that keeps its inherent simplicity and improves the tracking efficiency. First, a single-diode model for PV cells was used to compute the tracking efficiency versus irradiance. Computations were carried out for different values of the parameters involved in the PV cell model. The proposed approach clearly outperformed the FOCV method, specially at low irradiance, which is significant for powering sensor nodes. Experimental tests performed with a 500 mW PV panel agreed with these results. 1. Introduction The advances in electronics and communication protocols have led to a widespread use of wireless sensor networks (WSN). In most applications, the sensor nodes of the WSN are required to be wireless both for communication and powering.Asforthepowersupply,theuseofsmall-size PV cells or modules has been proposed. The power-voltage (P-V)curveofaphotovoltaic(PV)cellorpanelpresents a maximum power point (MPP) that changes with temperature and irradiance. To extract the maximum power under varying conditions an MPP tracker can be used. Several MPP tracking (MPPT) methods have been proposed in the literature [1–4]. Since sensor nodes present limited computing resources, low complexity MPPT methods are preferred for this particular application. Because the location of the sensor nodes is mostly determined by the application, a wide range of irradiance can be expected at the sensor placement. Thus, a high efficiency is desirable over a wide range of irradiance, and specially for low irradiance as the power source is scarce. One of the simplest and most popular MPPT methods is the fractional open circuit voltage (FOCV) technique, which estimates the MPP voltage (𝑉MPP) from a fraction of the open circuit voltage (𝑉OC); that is, 𝑉MPP,est =𝑘𝑉 OC,(1) where 𝑉MPP,est istheestimatedvalueoftheactual𝑉MPP and 𝑘 is an empirical constant whose value should be set following a thorough characterization of the PV panel under varying meteorological conditions (irradiance and cell temperature). 𝑉OC is either measured periodically (by momentarily opening the output of the PV panel) or by using a pilot cell (i.e., an additional solar cell of the same type configured in open circuit voltage configuration). Typical reported values for 𝑘 range from 0.73 to 0.8 depending on the PV panel type and characteristics [2,3]. Because of its simplicity, the FOCV method has been recently applied to small-size PV cells in order to power autonomous sensors [5–9]. In this work, we propose to generalize (1) in order to estimate 𝑉MPP by using a linear fit; that is, 𝑉MPP,est =𝑎𝑉 OC +𝑏, (2) where 𝑎and 𝑏are empirical coefficients. The use of (2)will be referred to as the linear open circuit voltage (LOCV) Hindawi Publishing Corporation International Journal of Photoenergy Volume 2014, Article ID 153428, 7 pages http://dx.doi.org/10.1155/2014/153428 2International Journal of Photoenergy method. In fact, the FOCV method can be considered a particular case of the proposed LOCV method with 𝑏=0. Both computed and experimental results of the proposed approach will be presented and compared with the FOCV method.Aswillbeshown,theLOCVmethodsignificantly improves the performance of the FOCV method, especially at low irradiance, while maintaining its inherent simplicity. The work presented here builds upon [10],wherewefirst presented (2) and some initial results. 2. Solar Cell Model Different equivalent circuits have been used in the literature in order to model the current/voltage (I-V)characteristicofa silicon PV cell [11–15]. Among them, the single-diode model, shown in Figure 1, offers a good compromise between simplicity and accuracy [13], whereby 𝐼PH is the photogenerated current, 𝐼is the cell current, 𝑉is the cell voltage, and 𝑅s and 𝑅pare, respectively, the series and shunt resistances. This model will be used here in order to generate computed data of the I-V curve of a PV cell. The corresponding expression of the I-V characteristic is given by [16] 𝐼=𝐼 SC −𝐼O[𝑒((𝑞(𝑉+𝑅s𝐼))/𝑛d𝐾𝑇cell)−1]−𝑉+𝑅s𝐼 𝑅p,(3) where 𝐼PH has been approximated by 𝐼SC,theshortcircuit currentofthecell;𝐼Ois the saturation current of the diode; 𝑞is the electron charge; 𝑛distheidealityfactorofthediode, which, for silicon, is usually between 1 and 2 [5,7]; 𝐾is the Boltzmann constant; and 𝑇cell is the cell temperature in Kelvin. By considering open circuit conditions (𝐼 = 0and 𝑉= 𝑉OC)in (3), we can write the parameter 𝐼Oas 𝐼O=𝐼SC −(𝑉 OC/𝑅p) [𝑒(𝑞𝑉OC/𝑛d𝐾𝑇cell)−1].(4) The parameters 𝐼SC and 𝑉OC in (3)and(4)changewiththe irradiance and temperature as 𝐼SC (𝑇cell,𝐺)=𝐺 1000[𝐼SCr+𝛼(𝑇cell −𝑇r)],(5) 𝑉OC (𝑇cell,𝐺)=[𝑉OCr+𝛽(𝑇cell −𝑇r)] ×[1+𝜌OC ln (𝐺 𝐺OC )ln (𝐺 𝐺r)], (6) where 𝑇cell is the cell temperature; 𝐺is the incident irradiance (in W/m2); 𝛼and 𝛽are the current and voltage temperature coefficients, respectively; 𝐼SCrand 𝑉OCrare given at a reference irradiance (𝐺r) and reference cell temperature (𝑇r); and 𝜌OC and 𝐺OC are two empirical constants used to model the significant variation of 𝑉OC at low 𝐺.Typically,𝐺r= 1000W/m2(=100 mW/cm2)and𝑇r=25 ∘C. Values of 𝜌OC = −0.04and 𝐺OC = 1000W/m2are adequate for many silicon PV cells [17]. When directly illuminated, solar cells heat up − + I V Rs Rp IPH Figure 1: Single-diode model of a solar cell with series (𝑅s)and shunt (𝑅p) resistances. above the ambient temperature (𝑇a), which is known as the self-heating effect, and 𝑇cell canbeobtainedfrom 𝑇cell =𝑇 a+𝑇cell,NOCT −20 800W/m2𝐺. (7) where 𝑇cell,NOCT,knownasthenominal operating cell temperature (NOCT), is the temperature of the cell when exposed to 800 W/m2at 𝑇a=20 ∘C and wind speed of 1 m/s. It is empirically determined, and for silicon solar cells range between 42∘Cand48 ∘C. 3. Computed Results We employed (3)to(7) with the following parameter values typical of monocrystalline solar cells [17]: 𝐽SCr=35mA/cm2; 𝑉OCr= 0.6V; 𝛼/𝐴 =12.5𝜇A/cm2/∘C; 𝛽=−2mV/∘C; and 𝑇cell,NOCT =42 ∘C. The parameters 𝐼SCrand 𝛼in (5)canbe,respectively, obtained by multiplying 𝐽SCrand 𝛼/𝐴by the area of the cell. For the computations, a single solar cell with an area of 1 cm2wasused.Nevertheless,aswillbejustifiedatthe end of this section, the results and the derived conclusions are equally valid to cells of any area and PV panels composed of an arbitrary number of solar cells disposed in parallel and series. Figure 2 shows the computed I-Vand P-Vcurves at three different levels of irradiance for the particular case of 𝑅s=0,𝑅p=∞,𝑛d=1.5,and𝑇a=25∘C. To obtain the data we simulated the PV cell model in SPICE. The power values were obtained by multiplying 𝐼by 𝑉at each data point. As can be seen, both 𝑉OC and 𝑉MPP slightly decrease at the highest irradiance, which is due to the self-heating effect of the PV cell. From the data of the I-V and P-V curves, several parameters can be obtained such as 𝑉OC,𝑉MPP,and𝑃MPP (power at the MPP). Table 1 shows numerical values of those parameters for an irradiance range from 𝑐𝑎.20W/m 2to 1000 W/m2. Fourteen points of irradiance, logarithmically equally spaced, were selected to provide a dynamic range around 100 in 𝑃MPP.Othercasesthatwillbediscussed throughout this section are also shown in Table 1.Figure 3 International Journal of Photoenergy 3 Table 1: Computed VOC,VMPP;andPMPP data at fourteen points of irradiance, logarithmically equally spaced, and for different values of the parameters of the PV cell model. G (W/m2)𝑛d=1.5(Figure 1)𝑛d=1 𝑛d=2 𝑟s=0.1(Figure 6)𝑟p=10(Figure 8) VOC (V) VMPP (V) PMPP (mW) VOC (V) VMPP (V) PMPP (mW) VOC (V) VMPP (V) PMPP (mW) VOC (V) VMPP (V) PMPP (mW) VOC (V) VMPP (V) PMPP (mW) 23.7 0.262 0.194 0.135 0.262 0.207 0.153 0.262 0.185 0.121 0.262 0.193 0.134 31.6 0.311 0.237 0.227 0.311 0.251 0.254 0.311 0.226 0.205 0.311 0.235 0.225 42.2 0.357 0.277 0.362 0.357 0.293 0.401 0.357 0.264 0.330 0.357 0.275 0.359 0.241 0.126 0.095 56.2 0.398 0.313 0.553 0.398 0.331 0.609 0.398 0.300 0.507 0.398 0.311 0.548 0.306 0.168 0.168 75 0.434 0.347 0.826 0.434 0.365 0.904 0.434 0.332 0.761 0.434 0.343 0.816 0.369 0.221 0.299 100 0.467 0.376 1.2 0.467 0.396 1.312 0.467 0.361 1.113 0.467 0.372 1.186 0.42 0.282 0.524 133.4 0.495 0.402 1.725 0.495 0.422 1.874 0.495 0.385 1.600 0.495 0.395 1.693 0.462 0.337 0.899 177.8 0.518 0.423 2.431 0.518 0.444 2.635 0.518 0.406 2.259 0.518 0.415 2.374 0.494 0.379 1.477 237.1 0.537 0.440 3.38 0.537 0.461 3.657 0.537 0.422 3.146 0.537 0.429 3.279 0.519 0.409 2.321 316.2 0.55 0.452 4.64 0.55 0.474 5.013 0.55 0.434 4.321 0.55 0.437 4.458 0.537 0.43 3.500 421.7 0.558 0.458 6.28 0.558 0.481 6.786 0.558 0.441 5.853 0.558 0.439 5.961 0.548 0.443 5.094 562.3 0.56 0.459 8.386 0.56 0.482 9.067 0.56 0.441 7.812 0.56 0.433 7.821 0.553 0.448 7.185 749.9 0.555 0.454 11.031 0.555 0.477 11.943 0.555 0.436 10.264 0.555 0.42 10.035 0.55 0.446 9.850 1000 0.543 0.442 14.254 0.543 0.464 15.472 0.543 0.424 13.234 0.543 0.398 12.511 0.54 0.436 13.13 0 0.1 0.2 0.3 0.4 0.5 0.6 0 12.5 25 37.5 50 0 4 8 12 16 PMPP versus V MPP 1000 W/m2 500W/m2 100 W/m2 I(mA) V(V) P(mW) Figure 2: Generic I-V and P-V plots at several values of 𝐺and at 𝑇a=25∘C for a single solar cell with an area of 1 cm2. A curve joining theMPPsisalsoplotted. represents the fourteen computed points (diamonds) of 𝑉MPP versus 𝑉OC and two least-squares regression lines fitted to thecomputeddatacorresponding,respectively,totheFOCV method, that is, (1)with𝑘=0.809,andtheLOCVmethod, that is, (2)with𝑎=0.894and 𝑏=−0.041.Ascanbeseen,the regression line corresponding to the LOCV method better fits the computed data. The inferred parameters of the regression lines (𝑘,𝑎,and𝑏)wereusedtoobtain𝑉MPP,est at the fourteen irradiance points for each of the two methods, by using (1) and (2), respectively. The corresponding power values at 𝑉MPP,est,𝑃MPP,est were inferred from the computed P-Vcurves in order to obtain the tracking efficiency, which is given by 𝜂MPP =𝑃MPP,est 𝑃MPP .(8) 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.55 0.6 nd= 1.5, Ta=25 ∘C,R s=0,and Rp=∞ V MPP versus V OC V MPP (V) V OC (V) LOCV V MPP,est = 0.894V OC − 0.041 FOCV V MPP,est = 0.809V OC Figure 3: Computed 𝑉MPP versus 𝑉OC for a single PV cell. Two least-square regression lines are also represented: the grey line corresponds to the FOCV method with 𝑘 = 0.809 whereas the black line corresponds to the LOCV method with 𝑎 = 0.894and 𝑏 = −0.041. The parameters of the PV cell model are 𝑇a=25∘C, 𝑛d=1.5,𝑅s=0,and𝑅p=∞. This parameter is used in the literature to compare the performance among different algorithms. Obviously, a valueof1(100%)istheultimategoal.Figure 4 shows the computed values of 𝜂MPPT versus 𝐺at 𝑇a=25 ∘Cfor the fourteen irradiance points. We added the results at two more temperatures, 0∘Cand50 ∘C. For these temperatures, the P-Vcurves were recalculated but we still used the same regression lines of Figure 3.Thismakessense,asa PV panel can be characterized at a single temperature, for example, 25∘C, and the calculated regression lines used for 4International Journal of Photoenergy 94 95 96 97 98 99 100 10 100 1000 nd= 1.5, Rs=0,and Rp=∞ 𝜂MPPT (%) G(W/m2) LOCV Ta=25 ∘C LOCV Ta=0 ∘C LOCV Ta=50 ∘C FOCV Ta=25 ∘C FOCV Ta=0 ∘C FOCV Ta=50 ∘C Figure 4: Computed 𝜂MPPT versus 𝐺by using the FOCV and LOCV methods for a single PV cell at different values of 𝑇aand with 𝑛d= 1.5,𝑅s=0,and𝑅p=∞. the full working temperature range. As can be seen, at low irradiance the LOCV method clearly outperforms the FOCV method. At higher irradiance, a rather high value of 𝜂MPPT (>99%) is achieved by both methods, although the FOCV method presents the lowest efficiency from 𝑐𝑎.100W/m 2to 1000 W/m2at 𝑇a=0∘C. The value of 𝜂MPPT for the LOCV methodwasalwayshigherthan99.8%atthethreecomputed temperatures. More computations were carried out at 𝑇a=25 ∘Cfor 𝑛d=1and 𝑛d=2(see Table 1). Again, better linear fits were obtained with the LOCV method (not shown). Figure 5 shows the corresponding computed values of 𝜂MPPT. Foreachofthecases,theparametersofthecorresponding regression lines are provided. Again, the LOCV method clearlyoutperformstheFOCVmethodatlowirradianceand slightly at medium irradiance. Finally, computations were performed for 𝑛d= 1.5,𝑇a= 25∘C, nonzero values of 𝑅s,andfinitevaluesof𝑅p.In[13] normalized values for 𝑅sand 𝑅pwere defined as 𝑟s=𝑅s [𝑉OC/𝐼SC]STC , 𝑟p=𝑅p [𝑉OC/𝐼SC]STC .(9) This normalization allows for an immediate comparison among different PV modules (of different area and characteristics). Based on [13], in our work we considered the following values: from 0.01 to 0.1 for 𝑟sand from 100 to 10 for 𝑟p.The performance for both 𝑟s= 0.01 and 𝑟p= 100 was almost identical to that shown in Figure 2 (for 𝑇a=25∘C), with the LOCV method outperforming the FOCV method. So these 𝜂MPPT (%) G(W/m2) 96 96.5 97 97.5 98 98.5 99 99.5 100 10 100 1000 Ta=25 ∘C,R s=0,and Rp=∞ V MPP, est = 0.926V OC − 0.037 LOCV nd=1 V MPP, est = 0.864V OC − 0.043 LOCV nd=2 V MPP, est = 0.850V OC FOCV nd=1 V MPP, est = 0.776V OC FOCV nd=2 Figure 5: Computed 𝜂MPPT versus 𝐺by using the FOCV and LOCV methods for a single PV cell at different values of 𝑛dand with 𝑇a= 25∘C, 𝑅s=0,and𝑅p=∞. results are not shown here. Table 1 shows the data for the limiting cases 𝑟s= 0.1 (with 𝑟p=∞)and𝑟p=10(with 𝑟s=0). For the case of 𝑟p=10, the data for the lowest two irradiance levels were not used as they provided negligible values of 𝑃MPP (well below of 1% of the resulting 𝑃MPP at 1000 W/m2). As for 𝑟s= 0.1,Figure 6 shows the computed values of 𝑉MPP versus 𝑉OC andthefittedregressionlines. Due to the high value of 𝑟s(highest limit), the data values present a folded form at the highest irradiance levels. So the regression lines of the FOCV and LOCV methods cannot fit thedatacorrespondingtothehighirradiancelevelsaswellas that in Figure 3.Otherwise,bothlinesareverysimilarinthis case. Consequently, the computed values of 𝜂MPPT,shownin Figure 7 (𝑟s= 0.1), are quite similar (and indeed relatively high) for both methods. As for 𝑟p=10,Figure 8 again shows the computed values of 𝑉MPP versus 𝑉OC andthefittedregressionlines.Dueto thelowrelativevalueof𝑟p(lowest limit) the regression line of the LOCV method cannot fit the data corresponding to the low irradiance levels as well as that in Figure 3.Evenso, the computed values of 𝜂MPPT,alsoshowninFigure 7,still present a high efficiency, outperforming the FOCV method at all the irradiance levels, but specially at the low ones. Finally, we computed 𝜂MPPT for 𝑟s=0.1and 𝑟p=10(not shown). In that case, the LOCV method also outperformed the FOCV method at low and medium irradiance levels. Increasing the PV cell area or adding identical PV cells in parallel will scale up the values of currents and thus of powers but the values of 𝑉OC and 𝑉MPP will remain the same and so the derived tracking efficiencies. Tracking efficency will also International Journal of Photoenergy 5 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.2 0.3 0.4 0.5 0.6 rs= 0.1, nd= 1.5, Ta=25 ∘C, and rp=∞ V MPP (V) V OC (V) LOCV V MPP,est = 0.801V OC − 0.01 FOCV V MPP,est = 0.779V OC V MPP versus V OC Figure 6: Computed 𝑉MPP versus 𝑉OC for a single PV cell with 𝑇a=25 ∘C, 𝑛d=1.5,𝑟p=∞,and𝑟s= 0.1.Tworegression lines corresponding to the FOCV and LOCV methods are also represented. 75 80 85 90 95 100 10 100 1000 nd= 1.5 and Ta=25 ∘C 𝜂MPPT (%) G(W/m2) LOCV rs= 0.1 LOCV rp=10 FOCV rs= 0.1 FOCV rp=10 Figure 7: Computed 𝜂MPPT versus 𝐺by using the FOCV and the LOCVmethodsforasinglePVcellwith𝑇a=25∘C, n𝑑=1.5,and for both 𝑟s=0.1(and 𝑟p=∞)and𝑟p=10(and 𝑟s=0). remain constant by adding PV cells in series: both 𝑉MPP and 𝑉OC will scale up by the number of serial cells but their ratio will remain constant and so the derived tracking efficiencies. 4. Experimental Results The LOCV method was tested with a 500 mW (𝐼SC =160mA, 𝑉OC = 4.6 V) PV panel (MSX-005, Solarex) and compared with the FOCV method. These low-power panels are used, for example, to power autonomous sensors [5–10]. In order 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0.2 0.3 0.4 0.5 0.6 rp= 10, nd= 1.5, Ta=25 ∘C, and rs=0 V MPP (V) V OC (V) LOCV V MPP,est = 1.098V OC − 0.163 FOCV V MPP,est = 0.760V OC V MPP versus V OC Figure 8: Computed 𝑉MPP versus 𝑉OC for a single PV cell with 𝑇a=25 ∘C, 𝑛d= 1.5,𝑟s=0,and𝑟p=10.Tworegression lines corresponding to the FOCV and LOCV methods are also represented. to achieve reproducible results, we implemented a PV panel simulator by connecting a current source (GS610, Yokogawa) in parallel with the PV panel, which was coated with an opaque cover (Figure 9). In this way, the short circuit current (𝐼SC) of the PV panel was adjusted by the current source, emulating different levels of irradiance. Since the panel was not illuminated, 𝑇celL,NOCT =20 ∘C(i.e.,thepanelisnotoverheated). The current source was configured to cover the full range of the PV panel, varying from 5 mA to 158 mA in 9 mA steps. The PV panel simulator was characterized by using the GS610’s measurement unit to measure the panel’s voltage, a 2001 multimeter (Keithley) to measure the current of the panel, and a programmable voltage source (Agilent E3631A) in parallel with a 10 Ω/1 W resistor acting as a load. Figure 9 shows the experimental setup. AlltheinstrumentswerecontrolledviatheGPIBbus with a dedicated program using the graphical development environment LabVIEW. For each current value (𝐼SC), the voltage of the E3631A was increased from 0 V to 5 V in 0.1 V steps. PV output voltages and currents were measured and the corresponding power values were calculated in order to obtain the I-V and P-V curves. From each P-V curve the values of 𝑉OC,𝑉MPP,and𝑃MPP were obtained. The limit values for 𝑃MPP were, respectively, 8.2 mW (𝐼SC =5mA)and545.9mW (𝐼SC =158mA). Figure 10 represents the experimental data of 𝑉MPP versus 𝑉OC and two fitted least-squares regression lines corresponding to the FOCV and LOCV methods. As can be seen, the regression line corresponding to the LOCV method better fits the experimental data. From the two regression lines, the values of 𝑉MPP,est corresponding to the FOCV and LOCV methods were derived. Then, from the P-Vcurves, the values of 𝑃MPP,est and 𝜂MPPT were obtained. Figure 11 shows 𝜂MPPT versus 𝑃MPP. In agreement with the computed results of Section 3, the LOCV method clearly outperformed the 6International Journal of Photoenergy − − + = ISC iPV I-Vcurrent source I-Vdiode I-VPV array simulator Covered PV panel GS610 Power source PV array simulator Multimeter 2001 (keithley) E3631A Power source (Agilent) IDiode 10 Ω PV Figure 9: The PV array simulator and the setup used for its characterization. 3 3.2 3.4 3.6 3.8 4 4.2 4.4 4.6 4.8 5 2 2.5 3 3.5 4 PV array simulator V MPP versus V OC LOCV V MPP,est = 1.067V OC − 1.182 FOCV V MPP,est = 0.798V OC V MPP (V) V OC (V) Figure 10: 𝑉MPP versus 𝑉OC for a 500 mW panel simulator at 𝑇a= 25∘C and two fitted least-square regression lines corresponding to the FOCV and LOCV methods. 0100 200 300 400 500 600 92 93 94 95 96 97 98 99 100 LOCV V MPP,est = 1.067V OC − 1.182 𝜂MPPT (%) FOCV V MPP,est = 0.798V OC PMPP (mW) Figure 11: Experimental 𝜂MPPT versus 𝑃MPP by using the FOCV method (grey line), with 𝑘 = 0.798,andtheLOCVmethod(black line), with 𝑎=1.0674and 𝑏=−1.182,fora500mWPVpanel. FOCV method at low irradiance, with 𝜂MPPT always being higher than 99.96%. The efficiency increase at low irradiance is of significant importance in order to power sensor nodes. 5. Conclusion PV cells have been proposed in the literature in order to power the sensor nodes of WSN. Because of the limited computing capabilities of the sensor nodes, simple MPPT methodshavetobeused.Amongthem,theFOCVmethod has been widely proposed and used. Tracking efficiencies, though, are lower than that achieved with more complex methods. In this work, we have proposed the LOCV method, which outperforms the FOCV method while maintaining its inherent simplicity. Computations show that the LOCV method achieves a high efficiency for all the irradiance range whereas the FOCV method fails in achieving a high efficiency at low irradiance levels for most of the cases. The presence of extremely low values of shunt resistance of the PV cell negatively impacts the achieved efficiency on both methods but specially that of the FOCV method. Finally, experimental data from a low-power 500 mW PV panel confirmed the good performance of the LOCV method for a wide range of irradiance, which is of significant value for powering sensor nodes. Conflict of Interests The authors declare that there is no conflict of interests regarding the publication of this paper. Acknowledgment ThisworkwassupportedbytheSpanishMinistryofEconomy and Competitiveness under Contract TEC2011-27397. References [1] T. Esram and P. L. Chapman, “Comparison of photovoltaic array maximum power point tracking techniques,” IEEE Transactions on Energy Conversion,vol.22,no.2,pp.439–449,2007. International Journal of Photoenergy 7 [2] N. Onat, “Recent developments in maximum power point tracking technologies for photovoltaic systems,” International Journal of Photoenergy,vol.2010,ArticleID245316,11pages, 2010. [3] D. P. Hohm and M. E. Ropp, “Comparative study of maximum power point tracking algorithms,” Progress in Photovoltaics: Research and Applications,vol.11,no.1,pp.47–62,2003. [4]V.Salas,E.Ol ´ ıas, A. Barrado, and A. L´ azaro, “Review of the maximum power point tracking algorithms for stand-alone photovoltaic systems,” Solar Energy Materials and Solar Cells, vol. 90, no. 11, pp. 1555–1578, 2006. [5] D. Dondi, A. Bertacchini, D. Brunelli, L. Larcher, and L. Benini, “Modeling and optimization of a solar energy harvester system for self-powered wireless sensor networks,” IEEE Transactions on Industrial Electronics,vol.55,no.7,pp.2759–2766,2008. [6] A. S. Weddell, G. V. Merrett, and B. M. Al-Hashimi, “Photovoltaic sample-and-hold circuit enabling MPPT indoors for low-power systems,” IEEE Transactions on Circuits and Systems I,vol.59,no.6,pp.1196–1204,2012. [7] A. Chini and F. Soci, “Boost-converter-based solar harvester for low power applications,” Electronics Letters,vol.46,no.4,pp. 296–298, 2010. [8] F. I. Simjee and P. H. Chou, “Efficient charging of supercapacitors for extended lifetime of wireless sensor nodes,” IEEE Transactions on Power Electronics,vol.23,no.3,pp.1526–1536,2008. [9] O. Lopez-Lape˜ na and M. T. Penella, “Low-power FOCV MPPT controller with automatic adjustment of the sample&hold,” Electronics Letters, vol. 48, no. 20, pp. 1301–1303, 2012. [10] M. T. Penella and M. Gasulla, “Optical energy harvesting,” in Powering Autonomous Sensors,chapter5,section5.5,pp.101– 107,Springer,Dordrecht,TheNetherlands,2011. [11] J. A. Gow and C. D. Manning, “Development of a photovoltaic array model for use in power-electronics simulation studies,” IEE Proceedings: Electric Power Applications,vol.146,no.2,pp. 193–200, 1999. [12] M. G. Villalva, J. R. Gazoli, and E. R. Filho, “Comprehensive approach to modeling and simulation of photovoltaic arrays,” IEEE Transactions on Power Electronics, vol. 24, no. 5, pp. 1198– 1208, 2009. [13] C.Carrero,J.Amador,andS.Arnaltes,“Asingleprocedurefor helping PV designers to select silicon PV modules and evaluate the loss resistances,” Renewable Energy,vol.32,no.15,pp.2579– 2589, 2007. [14] W.deSoto,S.A.Klein,andW.A.Beckman,“Improvementand validation of a model for photovoltaic array performance,” Solar Energy,vol.80,no.1,pp.78–88,2006. [15]F.Adamo,F.Attivissimo,A.DiNisio,andM.Spadavecchia, “Characterization and testing of a tool for photovoltaic panel modeling,” IEEE Transactions on Instrumentation and Measurement, vol. 60, no. 5, pp. 1613–1622, 2011. [16] F. Lasnier and T. G. Ang, Photovoltaic Engineering Handbook, Adam Hilger, New York, NY, USA, 1990. [17] A. Luque and S. Hegedus, Handbook of Photovoltaic Science and Engineering,2003. Submit your manuscripts at http://www.hindawi.com Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Inorganic Chemistry International Journal of Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 International Journal of Photoenergy Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Carbohydrate Chemistry International Journal of Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Journal of Chemistry Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Advances in Physical Chemistry Hindawi Publishing Corporation http://www.hindawi.com Analytical Methods in Chemistry Journal of Volume 2014 Bioinorganic Chemistry and Applications Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Spectroscopy International Journal of Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 The Scientific World Journal Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Medicinal Chemistry International Journal of Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Chromatography Research International Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Applied Chemistry Journal of Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Theoretical Chemistry Journal of Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Journal of Spectroscopy Analytical Chemistry International Journal of Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Journal of Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Quantum Chemistry Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Organic Chemistry International Electrochemistry International Journal of Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Hindawi Publishing Corporation http://www.hindawi.com Volume 2014 Catalysts Journal of