Fuzzy controller applications in stand-alone photovoltaic systems

Cañada Bago, Joaquín,García Galán, Sebastián,Aguilera García, Jorge,Velasco Pérez, Juan Ramón,Magdalena Layos, Luis

Abstract

One of foremost problems in stand-alone photovoltaic systems consists on the election of a strategy for charge controllers. The charge controllers main function is the accumulation system protection, and this leads to an extension of the batteries lifetime, thus reducing, the long term economic cost of the installation. This document describes a Fuzzy Logic based charge controller. In order to show the designed charge controller operation, firstly, a succession of simulations have been carried out to try out the mentioned controller efficiency. Afterwards, the designed charge controller has been used on a real target system to control the charge and discharge processes of a battery in a real stand-alone photovoltaic system, that is installed, on the flat roof of the E.P.S. Jaén of the University of Jaén (Spain). Finally, comparative operation results of the fuzzy charge controller developed are exposed in this document.

Full text

1 FUZZY CONTROLLER APPLICATIONS IN STAND-ALONE PHOTOVOLTAIC SYSTEMS J. C. Bago, S. G. Galán, J. Aguilera Investigación y desarrollo en Energía Solar y Automática (IDEA). Dpto. de Electrónica. Universidad de Jaén. E.U.P. de Linares Alfonso X El Sabio, 28. 23700 Linares (Jaén) Spain E-mail: {jcbago, sgalan, aguilera}@ujaen.es Juan Ramón Velasco Pérez Dpto. Ingeniería de Sistemas Telemáticos Universidad Politécnica de Madrid . E.T.S.I. de Telecomunicación. Ciudad Universitaria s/n, 28040 Madrid Spain. E-mail: [email protected] Luis Magdalena Layos Dpto. Matemática Aplicada a las Tecnologías de la Información Universidad Politécnica de Madrid . E.T.S.I. de Telecomunicación. Ciudad Universitaria s/n, 28040 Madrid Spain. E-mail: [email protected] Abstract One of foremost problems in stand-alone photovoltaic systems consists on the election of a strategy for charge controllers. The charge controllers main function is the accumulation system protection, and this leads to an extension of the batteries lifetime, thus reducing, the long term economic cost of the installation. This document describes a Fuzzy Logic based charge controller. In order to show the designed charge controller operation, firstly, a succession of simulations have been carried out to try out the mentioned controller efficiency. Afterwards, the designed charge controller has been used on a real target system to control the charge and discharge processes of a battery in a real stand-alone photovoltaic system, that is installed, on the flat roof of the E.P.S. Jaén of the University of Jaén (Spain). Finally, comparative operation results of the fuzzy charge controller developed are exposed in this document. Keywords: Fuzzy Logic Controllers, Rules Based Systems, Charge Controller, Stand-alone PV-Systems. 1 INTRODUCTION The operation of the stand-alone photovoltaic systems depends not only on the individual quality of the elements that compose them, but also of the interaction between the same within system [1]. In this sense, the charge controller achieves an outstanding role. The charge controller functionality is focused mainly in the accumulation system protection (constituted by Lead-Acid batteries). In spite of the continuous evolution in the charge control strategies for the batteries, supported by the operation of the charge controller; in practical implementation, at present time, its output have a relative high error rate. However, there are many studies accomplished on the operation of batteries [2]. In these studies, we can notice the existence of an expert knowledge, which can be formalized as control rules in a Fuzzy control system [3]. 2 These controllers are expert systems [3] that incorporate human knowledge in their knowledge bases through fuzzy control rules and fuzzy membership function [3][4]. A Fuzzy controller is composed by a knowledge base, which incorporates the information given by the operator of the controlled process following some linguistic control rules pattern. In this document, the accomplished works carried out in order to implement a Fuzzy charge controller are described. We have to emphasize that though the current implementation, a high cost equipment such as a computer and an data acquisition system, is mainly used to analyse the behaviour of the controller. Future implementations will lack these elements, and therefore the designed device will carry out the present implemented functions. This work is structured on the following manner: In section 2, a short introduction to stand-alone photovoltaic systems will be accomplished, which will be focused on a study of the usual operation of the charge controllers that exist at present time. Section 3 will be devoted to the justification of using a Fuzzy control system for the charge controller, listing some desirable operation characteristics for a charge controller. In section 4, the description of a Fuzzy charge controller, simulated on a computer, will be established; the operation results will be showed in section 5. To test the supposed improvement of a fuzzy charge controller as compared to traditional charge controllers, two stand-alone photovoltaic systems have been considered; the first one uses a traditional charge controller and the second one incorporating a Fuzzy charge controller. The characteristics for each installation are described in section 6. Meanwhile, the description of the Fuzzy charge controller that it has been designed in the second installation is shown in section 7. In section 8, some of the operation results are exposed. Finally, section 9 is devoted to conclusions. 2 STAND-ALONE PHOTOVOLTAIC SYSTEMS. CHARGE CONTROLLER Photovoltaic solar energy is, actually and in a small scale, a reliable and clean form of electrical energy production. The fundamental reason, which has prevented the expansion this technology has been basically economic: a greater cost of solar produced kWh than its respective production using more conventional 3 technologies (oil, nuclear, coal, etc). Nevertheless, the growth of technology and the production of cheaper modules, the development of more advanced conditioning systems of power, the greater efficiency and reliability, etc., in association with the accomplishment of research projects, supported by national and international programs of financing and/or partial subsidy, allows to install increasingly effective and competitive systems with conventional generators of electrical energy. So, it is expected an increasingly use of this technology in the production of electrical energy in the world as a complement of conventional generation sources. There are different types of photovoltaic installations: The grid-connected photovoltaic systems (GCFS) are installation, which are designed in order to inject energy into the electrical net, either to sale the electrical production of our photovoltaic system, or to support the electrical net. In some occasions, the designated Standalone Photovoltaic Systems (SAFS)[7] are used, as for example in isolated places, in which supply is not easy through the electrical net. Approximately, 90% of the installed world power has been installed in SAFS [12]. A Stand-Alone Photovoltaic Systems, as shown in figure 2.1, is constituted by the following elements: Photovoltaic Generator: Produces electrical energy from the incident solar radiation. System of energy accumulation: Batteries inserted in the Stand-Alone Photovoltaic Systems are implemented in order to match different rates of production and demand of electrical energy. Charge Controller: Its function consists on protecting the system of accumulation and avoiding extreme behaviour cases that could injure the batteries. Inverter: It is used when we want to manage loads that require alternate current. Load: Elements fed with electrical energy. 2.1 Charge Controllers The generated electrical energy not only feeds the electrical load, but also, due to the surplus of generated energy, loads the accumulators. Therefore, the regulator system must avoid overcharges in the accumulator (because of an excessive voltage provided by the generator), and, on the other hand, prevent the overdischarging of the batteries (in case of an excessive feed to the load by the accumulation system). 4 In fact, the charge controller system must protect to the accumulator of extreme operation situations, independently of the size of the installation, of its design, and possible weather variations in consumption profiles, solar radiation and operation temperatures. All this, in order to achieve as final objective a longer useful life of the accumulation system. It exists different kinds of charge controllers [7], but the most frequently used in Stand-Alone Photovoltaic Systems is the two-switched serial controller (Generation and Consumption). In this serial controller, the generator switch disconnects the generator and the battery when the latter reaches to a value enough to overcharge itself. The consumption switch energy prevents to supply the voltage of the battery when it reaches to a minimal threshold. The characteristic values in this type of controller are the following [10]: Overcharging threshold voltage VSC: Maximum voltage that the regulator allows to reach the battery. If V>VSC then the battery is disconnected of the generator. Charge rearming Voltage VRC: It is the value of the battery voltage that enables the battery to the generator reconnection. In the figure 2.2 the overdischarging Histeresis cycle corresponding is presented. Overdischarge voltage threshold VSD: It is the minimal value allowed for the battery voltage before disconnecting it from the consumption. If V<VSD then the battery will be unplugged from the consumption. Rearming voltage for discharge VRD: It is the voltage value in the battery that causes the battery reconnection to consumption. In the figure 2.3 overdischarging Histeresis cycle is presented. 3 USE OF EXPERT KNOWLEDGE IN CHARGE CONTROLLERS As already it has been mentioned, the operation of the stand-alone photovoltaic systems depends not only on the individual quality of the element that compose it, interaction between the components also contribute to system action [1]. In this sense, the charge controller is especially important. On the same way, control strategies followed by the charge controller are very important factor that directly influence the maintenance and the useful lifetime of batteries. Special care should be paid on batteries because 5 they influencing considerably (20%- 30%) [6] in the accrued cost of the installation. In spite of the apparent simplicity in the operation of the load controllers, in practice, it is observed that load control in real system present a relatively high mistakes rate, that is, load controllers do not show some necessary quality requirements in photovoltaic systems [5]. This circumstance should be debt mainly, to the fact that the operation of these controllers does not take into account all aspects related to the load and discharge processes. Thus, when lead-acid batteries are used [2], it should be desirable to acquire certain operational characteristics; some of the most important ones can be expressed as follows: a) Batteries that work in a high discharge rates, supply smaller capacities, since the internal transformations are superficial. b) Low rate batteries discharge, increase their capacity since it is produced a better and more complete use of active materials and acid. c) As temperature decreases, the battery capacity decrease, since the viscosity of the acid lowers and the diffusion ionic processes happen slower. d) A positive aspect dealing with batteries, is that an adequate quantity of overcharge can avoid stratification problems. e) As a result of the battery obsolescence, its internal resistance increases, therefore the maximum load tension would have to increase in order to maintain the same load regime. f) It is interesting to accomplish flotation charges to preserve the batteries in a full charge state, even when they are not in operation; this action will compensate self-discharge losses. g) The lower temperature and the higher charge rate, affect negatively the charge acceptance. As can be appreciated, these are desirable operation characteristics. Nevertheless, they are not remarkably specific, these characteristics can be modelled using an expert system. In this way, a fuzzy controller can be obtained with a knowledge base, whose rules can represent the previously mentioned characteristics. 6 4 FUZZY CHARGE CONTROLLER The structure of the Fuzzy Charge Controller (FCC) is showed in the figure 4.1. State of charge (SOC), generated current (Igen) and load current (Iload) are the FCC inputs. The FCC output will determine the charge controller operation mode. We have to point out, that the state of the charge (SOC) of the battery we are working with, has an estimated value at each time instant is a function of the quantity of current that each time instant stores the battery and the value of the corresponding capacity at the quiescent point [7]. Equally, it is important to indicate that switches S1 and S2 showed in the figure 4.1 are not ON-OFF type, actually they are continuous type. For a given system characteristics to be controlled, it is only necessary to act on the overcharge and overdischarge states [9]. This circumstance will affect to the distribution of the Fuzzy sets, which will cover the mentioned states and the next zones. The data base contains information on the Fuzzy sets associated with each variable, independently if it is an input or an output. These Fuzzy sets are shown in the figure 4.2. We have to indicate that the represented Fuzzy sets are normalized in the interval [0,1]. We have designed two knowledge bases, the first one will act in the overcharge states (switch S1) and the second one will work in the states of overdischarge (switch S2). These knowledge bases are represented in tables 4.1 and 4.2. It is important to point out that the knowledge bases represent a small subset of the existing knowledge in relationship to the conditions in which the battery would be charged and discharged. Below, each rule of the two knowledge bases are explained: Rule B1-R1: The battery state of charge is normal and therefore a fully charge of the battery is allowed. Rule B1-R2: The battery state of charge is relatively high, and as the current generated by the photovoltaic generator is small, a fully charge of the battery is allowed. Rule B1-R3: The battery state of charge is relatively high, the current generated by the photovoltaic generator is high, and the current consumed by the load is low. In this circumstance the charge controller allows a partial charge of the battery. 7 Rule B1-R4: The battery state of charge is relatively high, the current generated by the photovoltaic generator is high, and the current consumed by the load is relatively high. In this case, the charge controller allows a fully charge of the battery. Rule B1-R5: The battery state of charge is relatively high and the current generated by the photovoltaic generator is high, the same as the current consumed by the load is relatively high. In this circumstance the charge controller permits a fully charge of the battery. Rule B1-R6: The battery state of charge is very high, therefore it is convenient not to charge the battery. For the overdischarge case, the knowledge base that it has been used is symmetrical to the previous one: Rule B2-R1: If the battery state of charge is very low, the current is not allowed to arrive to the load. Rule B2-R2: If the battery state of charge is relatively low and the current generated by the photovoltaic generator is high, it is permitted a fully energy consumption. Rule B2-R3: If the battery state of charge is relatively low, the current generated by the photovoltaic generator is low and the current consumed by the load is also low, fully the energy consumption is allowed. Rule B2-R4: If the battery state of charge is relatively low, the current generated by the photovoltaic generator is low and the current consumed by the load is normal, fully the energy consumption is permitted. Rule B2-R5: If the battery state of charge is relatively low, the current generated by the photovoltaic generator is low and the current consumed by the load is high, it is allowed a partially energy consumption. Rule B2-R6: If the battery state of the charge of the is high, fully the energy consumption is permitted. 5 SIMULATION RESULTS Before the installation of the real Fuzzy charge controller, we have worked with some mathematical models to calculate the current delivered by the photovoltaic generator, as well as the behaviour of the accumulation system; these operations will test the kindness, and therefore the viability in the utilization of a Fuzzy charge controller. Below we have commented some aspects related to the used models. 8 5.1 Model of the photovoltaic generator: The set of the modules that compose a photovoltaic system, constituents a unit designated as generation subsystem. From the modelling point of view, this element is the one that is mathematically better developed. These models are based on the solid-state physics. The problem we have to deal whit when modelling this subsystem consists on determining the parameters of the model. The equations that govern this model [7] are shown below.   −⋅⋅= P SC G e NII 1 (1) where P SC SG N IR ⋅= (2) C mV dT C /º 3. 2 −= (3) The physical meaning of these parameters is explained in the following: IG is the generated current, ISC is the short circuit current of the cell, VG is the battery tension, VOC is the open circuit tension of the cell, RSG is the serial resistance of the generator, RS is the cell serial resistance, rS is the normalized serial resistance, NS is the number of cells of the generator serially grouped, NP is the number of cells in parallel of the generator. A more detailed Information about the model of the photovoltaic generator can be found in [7]. 5.2 Model of the accumulation system: Special attention should be paid to the elected battery model, since it is the element that is intended to protect with the charge controller, so its correct modelling will directly affect the cogency of the obtained results. The battery model that has been used is proposed it by Copetti [2], this model represents precisely the variation of the main parameters of the battery during the charge and discharge processes. This model is composed by three submodel: one for the discharge process, other one for the charging and other one for the overcharge process. The mathematical expressions that constitute this model are exposed in the figure 5.1. 9 The results have been obtained simulating a 6Wp photovoltaic generator, and a 100Ah and 2V battery. The charge profiles considered have been from 19:00h to 24:00h with a 6Ah consumption for the overdischarge state and 2Ah for the overcharge state. For the radiation and temperature data, we have used real measured values in the locality of Jaén (Spain). In the figure 5.2 are shown the simulation results obtained for the overcharge state. This figure includes simulation results using the Fuzzy charge controller and the serial charge controller. Equally, in the figure 5.3 the obtained simulation results for the overdischarge state are presented. These figures illustrate the time evolution during a 10 days period of: the state of charge, current of the battery (Ibat: difference between current generated and current consumed). Some of the remarkable advantages that have been obtained using the Fuzzy Controller, is the increase of the quantity of current delivered to the battery, (negative Values of Ibat). Furthermore, the time evolution of the load state has been softened, this fact will allow a smaller battery deterioration. 6 REAL INSTALLATIONS In order to compare operation results between the behaviour of a serial charge controller and the Fuzzy charge controller designed, we have installed two stand-alone photovoltaic systems, one with a conventional serial charge controller and the other one with the Fuzzy charge controller previously explained. In figure 6.1, a photograph is presented, where the photovoltaic generators of the installations are shown; these generators are embedded in a greater importance installation support structure. The other installations components are located in the laboratory of Photovoltaic Solar Energy of the Escuela Politécnica Superior of Jaén (Spain). The global system structure installed is presented in figure 6.2. In this figure, the two stand-alone photovoltaic systems can be observed. The first one (SA-1), uses the serial charge controller, and the second one (SA-2), uses the Fuzzy charge controller. Below we described each of the elements that constitute the system. 6.1 Central computer: 16 KNOWLEDGE BASE FOR THE OVERCHARGE (B1) Nº ANTECEDENTS S1 R1 IF “SOC=N“ H R2 IF “SOC=H” and “IGEN=”L” H R3 IF “SOC=H” and “IGEN=”H” and “ICAR=L” N R4 IF “SOC=H” and “IGEN=”H” and “ICAR=N” H R5 IF “SOC=H” and “IGEN=”H” and “ICAR=H” H R6 IF “SOC=VH” L Table 4.1: Knowledge base for the overcharge. 17 KNOWLEDGE BASE FOR THE OVERDISCHARGE (B2) Nº ANTECEDENTS S2 R1 IF “SOC=VL “ L R2 IF “SOC=L” and “IGEN=”H” H R3 IF “SOC=L” and “IGEN=”L” and “ICAR=L” H R4 IF “SOC=L” and “IGEN=”L” and “ICAR=N” H R5 IF “SOC=L” and “IGEN=”L” and “ICAR=H” N R6 IF “SOC=N” H Table 4.2: Knowledge base for the overdischarge. 18 KNOWLEDGE BASE FOR THE OVERCHARGE (B1) Nº ANTECEDENTS S1 R1 IF “Vbat=VH“ VL R2 IF “Vbat=H” and “SOC=H” VL R3 IF “Vbat=H” and “SOC=”M” L R4 IF “Vbat=H” and “SOC=”L” M R5 IF “Vbat=M” H R6 IF “Vbat=L” H R7 IF “Vbat=VL” H Table 7.1: Knowledge base for the overcharge. 19 KNOWLEDGE BASE FOR THE OVERDISCHARGE (B2) Nº ANTECEDENTES S2 R1 IF “Vbat=VH” H R2 IF “Vbat=H” H R3 IF “Vbat=M” H R4 IF “Vbat=L” and “SOC=”H” M R5 IF “Vbat=L” and “SOC=”M” L R6 IF “Vbat=L” and “SOC=”L” VL R7 IF “Vbat=VL” VL Table 7.2: Knowledge base for the overdischarge. 20 GENERATORACCUMULATIONSYSTEMLOAD DCINVERTERGENERATORACCUMULATIONSYSTEMLOAD DCINVERTER Figure 2.1: Structure of a Stand-Alone Photovoltaic System. 21 PHOTOVOLTAICGENERATORACCUMULATIONSYSTEMVbatVrcVscOFFPHOTOVOLTAICGENERATORACCUMULATIONSYSTEM VbatVrcVscOFF Figure 2.2: Overcharge Histeresis cycle. 22 ACCUMULATIONSYSTEMVbatVsdVrdOFFACCUMULATIONSYSTEMVbatVsdVrdOFF Figure 2.3: Overdischarge Histeresis cycle. 23 S1S2KNOWLEDGEBASEDEFUZZIFICATORS1S2KNOWLEDGEBASEKNOWLEDGEBASEDEFUZZIFICATORS1S2KNOWLEDGEBASEKNOWLEDGEBASEDEFUZZIFICATORS1S2KNOWLEDGEBASEKNOWLEDGEBASEDEFUZZIFICATOR Figure 4.1: Structure of the Fuzzy charge controller. 24 Figure 4.2: Fuzzy set of Fuzzy charge controller. 25 ()()() 1010101.6712.241.97ln110.002252.452.011ln110.0022517.31852 QovchIovchgecggecVvvveIvTCIvTCIC ττ ⋅−  =+−⋅−  =+⋅+⋅−⋅−  =+⋅+⋅−⋅−  =  + Sobrecarga:Equivalencia:C10: Capacidad de la batería (Ah).I: Corriente en la batería (A).Q: Carga (Ah).V: Tensión en la batería (V).SOC: Estado de carga (0<SOC<1).T: Temperatura (ºC). t : Cte. Tiempo (h).Overcharge process:Equivalence:C10:Battery Capacity (Ah).Q:Charge (Ah).SOC: State of charge (0<SOC<1).τ:Cte. Time (h).I:Battery Current (A).V:Battery tension (Ah).T: Temperature (ºC).()()() 1010101.6712.241.97ln110.002252.452.011ln110.0022517.31852 QovchIovchgecggecVvvveIvTCIvTCIC ττ ⋅−  =+−⋅−  =+⋅+⋅−⋅−  =+⋅+⋅−⋅−  =  + Sobrecarga:Equivalencia:C10: Capacidad de la batería (Ah).I: Corriente en la batería (A).Q: Carga (Ah).V: Tensión en la batería (V).SOC: Estado de carga (0<SOC<1).T: Temperatura (ºC). t : Cte. Tiempo (h).Overcharge process:Equivalence:C10:Battery Capacity (Ah).Q:Charge (Ah).SOC: State of charge (0<SOC<1).τ:Cte. Time (h).I:Battery Current (A).V:Battery tension (Ah).T: Temperature (ºC). Figure 5.1: Copetti battery model [2]. 32 Figure 8.2: Comparison of experimental results. (II). 33 1,00E+011,50E+01 Iload(Fuzzy controller)Iload(Serial controller)Igen(Fuzzy controller) 1,00E+011,50E+01 Iload(Fuzzy controller)Iload(Serial controller)Igen(Fuzzy controller) Figure 8.3: Operation results during 5 consecutive days.