Determination of corneal sagittas for contact lens fitting in keratoconus

Larrosa Expósito, Manel

Full text

MÀSTER UNIVERSITARI EN OPTOMETRIA I CIÈNCIES DE LA VISIÓ TREBALL FINAL DE MÀSTER DETERMINATION OF CORNEAL SAGITTAS FOR CONTACT LENS FITTING IN KERATOCONUS (Determinació de sagites corneals per l’adaptació de lents de contacte en casos de queratocon) MANEL LARROSA EXPÓSITO DIRECTORS JOAN GISPETS PARCERISAS NÚRIA LUPÓN BAS DEPARTAMENT D’ÒPTICA I OPTOMETRIA 30 de Juny de 2021 Facultat d’Òptica i Optometria de Terrassa © Universitat Politècnica de Catalunya, any 2021.Tots els drets reservats MÀSTER UNIVERSITARI EN OPTOMETRIA I CIÈNCIES DE LA VISIÓ La Sra. Núria Lupón Bas i el Sr. Joan Gispets Parcerisas com a directors del treball CERTIFIQUEN Que la Sr. Manel Larrosa Expósito ha realitzat sota la seva supervisió el treball “Determinació de sagites corneals per l’adaptació de lents de contacte en casos de queratocon” que es recull en aquesta memòria per optar al títol de Màster en Optometria i Ciències de la Visió. I per a què consti, signo/em aquest certificat. Sra. Núria Lupón Bas Directora del treball Sr. Joan Gispets Parcerisas Director del treball Terrassa 16 de juny de 2021 Facultat d’Òptica i Optometria de Terrassa © Universitat Politècnica de Catalunya, any 2021.Tots els drets reservats MÀSTER UNIVERSITARI EN OPTOMETRIA I CIÈNCIES DE LA VISIÓ DETERMINACIÓ DE SAGITES CORNEALS PER L’ADAPTACIÓ DE LENTS DE CONTACTE EN CASOS DE QUERATOCON RESUM INTRODUCCIÓ: Un nou disseny de lent de contacte ha estat recentment proposat per a la correcció òptica del queratocon. Per al càlcul dels seus paràmetres és necessari disposar d'un topògraf Pentacam que, generalment, és poc emprat per a l'adaptació de lents de contacte. La nostra proposta és reemplaçar aquest instrument per un altre més comú en l’àmbit de la contactologia, concretament el topògraf Easygraph. OBJECTIU: Avaluar les diferències entre els valors de les sagites corneals obtingudes mitjançant el topògraf Pentacam i l’Easygraph, tant per a un grup d'ulls sans com per a un altre amb queratocon, i determinar si tots dos instruments es poden fer servir de manera intercanviable a l'hora de calcular els radis de curvatura de la nova lent experimental. MÈTODES: Les topografies de 26 ulls (20 sans i 6 amb queratocon), realitzades amb tots dos instruments, van ser cercades en la base de dades del CUV (Centre Universitari de la Visió). Es van mesurar les sagites corneals a partir del mapa d'elevació (Easygraph) i de les imatges de Scheimpflug (Pentacam) per a dues determinades cordes (D0i D1), en 3 meridians diferents (0-180º, 45-225º, 135-315º). Per al càlcul dels radis de curvatura de la lent es va fer servir un sistema basat en l'equació d'una circumferència en el pla XZ, amb centre en l'eix Z. RESULTATS: Es van trobar diferències estadísticament significatives entre les mesures obtingudes mitjançant tots dos topògrafs per a tots els casos (p < 0,0001). També es van trobar diferències entre grups (ull normal i queratocon) excepte quan es va avaluar D1mitjançant l’Easygraph. Els radis de curvatura de les lents calculades a partir de cada topògraf van mostrar diferències que, a priori, haurien de ser clínicament significatives (diferències superiors a 0,2 - 0,3 mm en molts casos). CONCLUSIONS: Mitjançant la metodologia emprada en el nostre estudi, tots dos topògrafs no poden utilitzar-se de manera intercanviable per a calcular els radis de curvatura de la nova lent experimental per a queratocon. Facultat d’Òptica i Optometria de Terrassa © Universitat Politècnica de Catalunya, any 2021.Tots els drets reservats MÀSTER UNIVERSITARI EN OPTOMETRIA I CIÈNCIES DE LA VISIÓ DETERMINACIÓN DE SAGITAS CORNEALES PARA LA ADAPTACIÓN DE LENTES DE CONTACTO EN CASOS DE QUERATOCONO RESUMEN INTRODUCCIÓN: Un nuevo diseño de lente de contacto ha sido recientemente propuesto para la corrección óptica del queratocono. Para el cálculo de sus parámetros es necesario disponer de un topógrafo Pentacam que, generalmente, es poco utilizado para la adaptación de lentes de contacto. Nuestra propuesta es reemplazar este instrumento por uno comúnmente utilizado en contactología, concretamente el topógrafo Easygraph. OBJETIVO: Evaluar las diferencias entre los valores de las sagitas corneales obtenidas mediante el topógrafo Pentacam y el Easygraph, tanto para un grupo de ojos sanos como para otro con queratocono, y determinar si ambos instrumentos pueden utilizarse de forma intercambiable a la hora de calcular los radios de curvatura de la nueva lente experimental. MÉTODOS: Las topografías de 26 ojos (20 sanos y 6 con queratocono), realizadas con ambos instrumentos, fueron buscadas en la base de datos del CUV (Centre Universitari de la Visió). Se midieron las sagitas corneales a partir del mapa de elevación (Easygraph) y de las imágenes de Scheimpflug (Pentacam) para dos determinadas cuerdas (D0y D1), en 3 meridianos distintos (0-180º, 45-225º, 135-315º). Para el cálculo de los radios de curvatura de la lente se utilizó un sistema basado en la ecuación de una circunferencia en el plano XZ, con centro en el eje Z. RESULTADOS: Se hallaron diferencias estadísticamente significativas entre las medidas obtenidas mediante ambos topógrafos para todos los casos (p < 0,0001). También se encontraron diferencias entre grupos (ojo normal y queratocono) excepto cuando se evaluó D1mediante Easygraph. Los radios de curvatura de las lentes calculadas a partir de cada topógrafo mostraron diferencias que, a priori, deberían ser clínicamente significativas (diferencias > 0,2 - 0,3 mm en muchos casos). CONCLUSIONES: Mediante la metodología utilizada en nuestro estudio, ambos topógrafos no pueden utilizarse de manera intercambiable para calcular los radios de curvatura de la nueva lente experimental para queratocono. Facultat d’Òptica i Optometria de Terrassa © Universitat Politècnica de Catalunya, any 2021.Tots els drets reservats MÀSTER UNIVERSITARI EN OPTOMETRIA I CIÈNCIES DE LA VISIÓ DETERMINATION OF CORNEAL SAGITTAS FOR CONTACT LENS FITTING IN KERATOCONUS ABSTRACT INTRODUCTION: A new contact lens design has been recently proposed for the optical correction of keratoconus. In order to determine the lens’ parameters, a Pentacam device is needed, which is rarely used for fitting contact lenses. Our proposal is to replace this instrument by an Easygraph topographer, which is widely used for this purpose. PURPOSE: To evaluate the differences between the corneal sagittal height measurements obtained from Pentacam and Easygraph, for two different groups (healthy and keratoconus eyes), and to determine whether both instruments can be used interchangeably when determining the radii of curvature of the new experimental lens. METHODS: Topographies of 26 eyes (20 healthy and 6 keratoconus eyes), taken with both instruments, were searched in the CUV (Centre Universitari de la Visió) database. Corneal sagittal height was obtained from the Easygraph elevation map as well as the Pentacam Scheimpflug images, for two different chords (D0and D1), in 3 different meridians (0-180º, 45-225º, 135-315º). In order to calculate the lens’ radii of curvature, a system based on the equation of a circumference in the XZ plane, with its center on the Z axis, was used. RESULTS: Statistically differences were found between measurements obtained with both topographers for all cases (p < 0.0001). Statistical differences were also found between groups (healthy and keratoconus group) except when D1was assessed with Easygraph. Lens radii of curvature calculated from each topographer showed differences that should (theoretically) be clinically significant (differences greater than 0.2 - 0.3 mm in many cases). CONCLUSIONS: Both topographers cannot be used interchangeably to determine the radii of curvature of the new experimental lens for keratoconus, at least using the methodology proposed in our study. Facultat d’Òptica i Optometria de Terrassa © Universitat Politècnica de Catalunya, any 2021.Tots els drets reservats Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ AGRAÏMENTS Aquest treball és fruit de la col·laboració de diverses persones, sense les quals no hauria estat possible la seva realització. Per aquest motiu vull agrair i reconèixer l’esforç i dedicació que els següents amics, companys i familiars han emprat durant la realització d’aquest treball de fi de màster: A la meva parella Lorena Lechado i a la meva germana Marta Larrosa, per donar-me ànims en els moments més difícils i per ajudar-me amb l'anglès, revisant la feina feta, tot cercant qualsevol possible error que hagués passat per alt. Als meus tutors del treball de fi de màster, Joan Gispets iNúria Lupón, per haver-me proposat i donat l'oportunitat de realitzar aquest estudi, a més de guiar-me i ajudar-me durant tot el transcurs del mateix. Al’equip d’optometristes i oftalmòlegs de l’hospital Mútua de Terrassa, per les imatges cedides de la base de dades de la seva làmpada d’escletxa i del seu topògraf. A més, va ser un plaer i tota una experiència poder treballar i aprendre amb ells durant el quadrimestre passat. A l’Enric Mas, per enviar-nos per escrit la metodologia que va emprar per a la mesura de les sagites corneals durant el transcurs de la seva tesi doctoral. Al professor i company Joan Pérez, per ajudar-nos amb la llista de pacients amb queratocon i per tot el que m’ha ensenyat sobre contactologia, no solament durant aquest últim quadrimestre, sinó durant aquests dos anys de màster. A tots vosaltres, moltes gràcies. Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ INDEX 1. INTRODUCTION…………………………………………………………………………………..1 2. STATE-OF-THE-ART KNOWLEDGE…………………………………………………………....2 2.1. KERATOCONUS DEFINITION AND CONCEPT…………………………………………….2 2.2. KERATOCONUS PREVALENCE……………………………………………………………...4 2.3. KERATOCONUS MORPHOLOGY AND CLASSIFICATION………………………………. 5 2.4. MORPHOLOGY OF THE CORNEAL PERIPHERY IN KERATOCONUS………………...8 2.5. NON-SURGICAL REFRACTIVE MANAGEMENT OPTIONS FOR KERATOCONUS....10 2.5.1. Regular soft contact lenses and spectacles……………………………………………....11 2.5.2. Thick soft contact lenses…………………………………………………………………....12 2.5.3. Corneal Rigid Gas-Permeable lenses……………………………………………………..13 2.5.4. Corneo-scleral Gas-Permeable lenses…………………………………………………....17 2.5.5. Miniscleral and Scleral lenses……………………………………………………………...18 2.5.6. Hybrid lenses………………………………………………………………………………... 20 2.5.7. Piggyback lens system……………………………………………………………………...20 2.5.8. Large-size corneal Gas-Permeable lenses………………………………………………. 22 3. RESEARCH OBJECTIVES…………………………………………………………………….. 23 3.1. GENERAL OBJECTIVE……………………………………………………………………….23 3.2. SPECIFIC OBJECTIVES……………………………………………………………………...23 4. MATERIAL AND METHOD……………………………………………………………………...24 4.1. DESCRIPTION OF THE SAMPLE AND STUDY DESIGN………………………………..24 4.2. MATERIAL……………………………………………………………………………………... 24 4.2.1. Easygraph (1.76 Version)............................................................................................ 24 4.2.2. Pentacam HR………………………………………………………………………………...25 4.2.3. JR Screen Ruler…………………………………………………………………………….. 26 4.3. METHOD………………………………………………………………………………………..27 4.3.1. Distribution of the sagittal height measurements………………………………………... 27 4.3.2. Easygraph previous assessment…………………………………………………………..28 4.3.3. Measuring D0 and D1 with Pentacam……………………………………………………..29 4.3.4. Measuring D0 and D1 with Easygraph…………………………………………………….32 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 4.3.5. Lens curvature radii determination………………………………………………………... 34 4.4. STATISTICAL ANALYSIS……………………………………………………………………..36 5. RESULTS………………………………………………………………………………………… 38 6. DISCUSSION……………………………………………………………………………………..44 7. CONCLUSIONS…………………………………………………………………………………. 46 8. LIMITATIONS OF THE STUDY AND FUTURE RESEARCH………………………………. 47 9. BIBLIOGRAPHIC REFERENCES……………………………………………………………...49 10. ANNEXES………………………………………………………………………………………. 53 10.1. ANNEX I……………………………………………………………………………………….53 10.2. ANNEX II………………………………………………………………………………………55 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 1. INTRODUCTION Keratoconus is a corneal disease that affects many people across the world. This condition usually deteriorates the patient's visual quality, especially in advanced and severe stages of the disease. Nowadays, there are a number of treatment options that aim to improve the quality of life of these patients. Contact lenses are one of the most common treatments used in keratoconus, since it is able to provide a significant visual enhancement without needing to undergo eye surgery. At present, contact lens practitioners are provided with many different lens designs, sizes (from small corneal to full scleral lenses) and materials (soft, gas-permeable and hybrid), allowing an adequate refractive management in many cases. However, none of these lens designs provide an ideal solution for all patients, existing numerous advantages but also some drawbacks that contact lens practitioners (and also patients) should be aware of. It is for this reason that new contact lens designs for keratoconus are still appearing, with the aim of providing new and improved refractive solutions for these patients. Recently, a novel lens design based on a corneal gas-permeable lens called KAKC (Conoptica Lab) was proposed in a doctoral thesis. The authors chose the KAKC lens because it allowed a customizable size diameter of every single zone of the lens (D0, D1, D2and D3) as well as its curvature radii (R0, R1, R2 and R3). The design proposed by the researchers was characterized by a large lens sizing (covering almost all of the corneal surface), which aimed to provide enough corneal vaulting to avoid any lens bearing on the apex of the cone. In the same doctoral thesis, a pilot study that involved 10 keratoconus patients (a total of 20 eyes) was also performed. In this study the researchers found encouraging results regarding the clinical use of their novel design for keratoconus. However, one of the main weaknesses of this design was that a Pentacam device was needed in order to determine the lens zones' curvature radii. It is well known that Pentacam is rarely used for fitting contact lenses while it is widely used in ophthalmology and for research purposes. This fact could be a barrier to the future lens commercialization since few optometrists have a Pentacam in their contact lens clinic. This study attempts to determine if Easygraph (a common device used for fitting contact lenses) is able to provide reliable corneal sagittal measures for fitting this novel lens design, as Pentacam does. 1 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 2.4. MORPHOLOGY OF THE CORNEAL PERIPHERY IN KERATOCONUS Corneal periphery is located between the paracentral cornea and the corneo-scleral limbus, being the most flatten and aspheric zone of the cornea. While other central areas have been widely described in keratoconus, corneal periphery has not been studied in such depth. This may be explained by the fact that, as stated above, main corneal morphology changes occur in the central and paracentral zones of the cornea. However, corneal periphery becomes a significant area in the contact lens field, as it plays the role of lens support in large-sized gas-permeable corneal lens fittings as well as in orthokeratology fittings. In the last few years, Optical Coherence Tomography (OCT) and Scheimpflug corneal imaging has allowed further investigation in this field. A novel methodology proposed by Mas-Aixalà et al. has recently described the periphery of the cornea using Scheimpflug images [39]. This study involved 60 eyes of 60 keratoconus patients (with different disease stages, from I to IV according to Amsler-Krumeich classification) as well as 28 eyes from 28 healthy subjects. Peripheral corneal angles were semi-manually measured from the Scheimplfug images provided by Pentacam using the methodology described in Fig. 2.9. Fig 2.9. Peripheral corneal angle measurement in a Scheimpflug image. The red line links both parts of the limbus, which, in the image, is depicted as the spot where the cornea loses its transparency. This line is used as a reference for tracing the X yellow segment, which is ten times shorter than the red line. The Y yellow segment links the end of the X segment with the corneal epithelium, being orthogonal to the red line. Finally, the peripheral corneal angle (θ) is calculated from both segments (X and Y) using trigonometry. 8 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ Peripheral corneal angles were measured in eight different corneal spots, obtaining two measures in each of the following meridians: 0-180°, 45-225°, 90-270°and 135-315° (Fig. 2.10). Fig 2.10. Peripheral corneal angle location for right eye (UD) and left eye (UE). S:Superior; NS: Nasal-Superior; N180: Nasal; NI: Nasal-Inferior; I: Inferior; TI: Temporal-Inferior; T180: Temporal; TS: Temporal-Superior. The results showed statistical differences between early keratoconus (stage I) and healthy eyes, being peripheral angles slightly lower in the healthy eye group. However, no statistical differences were found between early keratoconus (stage I) and the rest of the disease stages (from II to IV). These results may suggest that keratoconus leads to a slight increase of the corneal peripheral angles at the beginning of the disease, but seems to not progress as the ectasia does. In addition, the rotational symmetry degree of the peripheral cornea (defined as the difference between the higher and lower peripheral angle of an eye) was determined for keratoconus and healthy eyes. Similar mean values were found for both groups (3,37°± 1,42° in healthy eyes vs 2,96°± 1,54° in keratoconus eyes), suggesting that large gas-permeable contact lenses should exhibit an acceptable on-eye stabilization in keratoconus patients (as occurs in orthokeratology fittings), not needing a toroidal lens design in most of the cases. Mas-Aixalà et al. also proposed a keratoconus gas-permeable lens design (based on the KACK contact lens, Conoptica Lab) characterized by a large lens-diameter size, which aimed to land on the periphery of the cornea [39]. As previously mentioned, encouraging results were found in a first pilot study, which involved 10 keratoconus patients (20 eyes). Moreover, this study clinically confirmed that a toroidal lens geometry was usually not needed when fitting their contact lens design, as they needed a toroidal design only in 10% of the cases (in 2 of the total 20 eyes). 9 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 2.5. NON-SURGICAL REFRACTIVE MANAGEMENT OPTIONS FOR KERATOCONUS For many years, the optometric assessment and prescription of spectacles and contact lenses have been playing a major role in the eye-care management of keratoconus due to its capacity for improving the patient’s visual quality while respecting the physiology of the ocular surface, being a comfortable, reversible and secure treatment option. Certainly, a correct use of these refractive aids may influence the surgical management of these patients, delaying the need of surgery in almost all cases [25]. Surgical treatment alternatives for providing an enhancement of the visual quality include Keratoplasty and Intrastromal Corneal Ring Segment (ICRS) implantation. These alternatives are known to be invasive and traumatic procedures, which can rarely lead to serious ocular complications (e.g. rates of corneal graft rejection are around 5-10% approximately [43]) (Fig. 2.11). Furthermore, it is important to note that the longevity of a corneal graft is, at most, twenty to thirty years, so it is imperative to avoid Keratoplasty until it becomes strictly necessary in order to minimize the overall number of corneal transplantation performed during the lifetime of a young keratoconus patient. Fig 2.11. Postsurgical cornea complications in keratoconus. (A) Corneal graft rejection. (B) Intrastromal Corneal Ring Segment extrusion. (Image source: Mútua de Terrassa Hospital). Fortunately, many contact lens designs are available at the present time, providing an adequate refractive solution according to the stage of the disease, cone localization, patients preference, etc. The main features, advantages and drawbacks of each option will be discussed in the following sections. 10 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 2.5.1. Regular soft contact lenses and spectacles Soft contact lenses and spectacles have been proven useful until high-order aberrations and irregular astigmatism appear, commonly at mild keratoconus stages. Several studies have evaluated the use of these refractive devices in keratoconus patients. For instance, Griffiths et al. performed a study involving 13 individuals with different stages of the disease, which showed that spherical hydrogel soft lenses provide poorer high- and low-contrast visual acuities than the rigid corneal lens correction [26]. In another scientific investigation carried by Jinabhai et al., rigid corneal lenses provided an enhanced low-contrast acuity and a reduction of high-order aberrations compared to toric hydrogel soft lenses and spectacles [27]. However, spectacles and soft lenses are also provided with some benefits regarding the use of rigid lenses. Main advantages and disadvantages are summarized in Fig. 2.12. Fig 2.12. Main advantages and drawbacks of spectacles and soft contact lenses in keratoconus patients. 11 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ Additionally, contact lens practitioners should be aware of the patient’s pupil since, the greater the pupil size, the greater the amount of high-order aberrations will be revealed. Thus, different illumination conditions during the day may determine the soft lenses and spectacles visual success (Fig. 2.13). Fig 2.13. Visual performance of a mild to moderate keratoconus patient in different pupil scenarios. From left to right: High-order aberrations wavefront, patient’s visual image simulation and Point Spread Function (PSF) for (A) Pupil diameter of 3 millimetres (B) Pupil diameter of 5 millimetres and (C) Pupil diameter of 6 millimetres. (Source: Mútua de Terrassa Hospital). 2.5.2. Thick soft contact lenses Thick soft contact lenses attempt to mask corneal irregularities using an increased thickness of the lens’s optical zone. The main conclusion drawn from recent investigations is that these lenses are a suitable alternative when traditional rigid lens correction is impracticable [28]. It is important to remember that rigid material is usually preferred since it provides better visual outcomes in keratoconus patients. However, it is noteworthy that one retrospective analysis found similar visual acuities between patients being corrected with either thick soft lenses (Kerasoft IC) or rigid lenses 12 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ (Menicon Rose-K2) in mild to moderate stages of the disease [29]. Main advantages and disadvantages are summarized in Fig 2.14. Fig 2.14. Main advantages and drawbacks of thick soft contact lenses in keratoconus patients. Furthermore, a number of custom aberration-controlled designs have been developed during the past few years [30-32]. Although significant reductions to overall ocular aberrations have been demonstrated with these lenses, visual outcomes are worse than expected in many cases [31]. Researchers have concluded that many factors may explain this success variability, including the severity of the disease, the morphology of the cone and an inadequate centration and/or movement of the lens in-situ. 2.5.3. Corneal Rigid Gas-Permeable lenses Corneal lenses have been the most common form of rigid lens used for keratoconus for the past few decades [34]. Corneal irregularities are masked by the patient’s tears beneath the lens, neutralizing much of the corneal astigmatic error but not necessarily normalizing higher order aberrations [35, 36]. Standard lenses are commonly used during early keratoconus forms. However, special designs are needed as the ectasia progresses. In broad terms, these designs are characterized by a steeper back surface in the center and a flatter lens periphery, leading to a high lens eccentricity. According to the lens fluorescein pattern, three main fitting philosophies are recognized for corneal rigid keratoconus correction, namely, apical clearance, apical bearing and three-point-touch fitting. 13 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ In the apical clearance technique (Fig. 2.15), the rigid lens aims to avoid any touch with the center of the cornea, vaulting the ectatic cone and filling the lens-epithelium gap with tears. Simultaneously, the periphery of the lens must land on the paracentral cornea for centration and stabilization purposes. It has been postulated that this fitting technique should minimize the risk of suffering corneal scarrings and epithelial trauma on the center of the cornea, as the lens does not touch this significant area [37]. On the other hand, worse visual acuity is usually achieved with this arrangement and excessive pressure in the paracentral cornea may lead to lens binding, peripheral corneal disruption and impediment of tears exchange flow. Moreover, it has been hypothesized that apical clearance technique may induce transient corneal-moulding effects, which may increase the risk for ectasia progression in early keratoconus forms [38]. Fig 2.15. Apical clearance fitting technique. The fluorescein pattern reveals a significant gap between the central cornea and the back surface of the lens, which is filled with stained tears. Oppositely, the lens lands on the paracentral cornea, showing a darkened bow-shaped pattern. (Image Source: Centre Universitari de la Visió). Apical bearing fitting (Fig. 2.16) is characterized by significant lens support on the corneal apex. The main advantage is that better visual acuity outcomes are usually found compared to the other two fitting techniques. However, apical bearing is associated with an increased risk of epithelial abrasions, corneal scars and long-term rigid lens intolerance. For a long time, it was wrongly believed that this fitting technique was able to delay keratoconus progression due to the mechanical 14 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ compression and consequent physical resistance applied over the corneal surface. Thus, after years of clinical application, it is widely accepted that this technique should be avoided [44] . Fig 2.16. Apical bearing fitting technique. The fluorescein pattern reveals a heavy lens bearing on the ectatic cone, which is clinically viewed as an oval darkened area (marked with a red asterisk). The lens pressure regularizes the cornea and provides an enhanced visual acuity to the patient, but, at the same time, induces epithelial disruption, abrasions and corneal scars if the lens is long-term weared. (Image Source: Centre Universitari de la Visió). The three-point-touch technique (Fig. 2.17) aims to distribute the lens bearing along a large corneal area, with a smooth or “apparent” touch on the corneal apex and a greatest support on the paracentral cornea. Significant visual acuity outcomes are usually achieved with this technique, minimizing the risk of suffering corneal scars and facilitating tears flow beneath the lens. The main disadvantage with this fitting philosophy is that epithelium trauma, abrasions and consequent corneal scars are still possible, especially if the ectasia progresses between follow-up visits, shifting the cone further closer to the back surface of the lens. 15 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ Fig 2.17. Three-point-touch fitting technique. The fluorescein pattern shows an “apparent” touch on the area where the cone is located (arrowhead), which assists in the lens stabilization and centration. However, the primary lens support is distributed on two paracentral areas of the cornea, which, in this case, is clinically viewed as two darkened semicircles (marked both with a red asterisk). (Image Source: Centre Universitari de la Visió). Finally, overall advantages and disadvantages of corneal rigid lenses are summarized in Fig. 2.18. Fig 2.18. Main advantages and drawbacks of corneal rigid lenses in keratoconus patients. 16 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 2.5.4. Corneo-scleral Gas-Permeable lenses Because the physiology of the ocular surface being more respected in corneal lens fittings, corneo-scleral rigid lenses are usually fitted when the correction with smaller lenses is not possible. The weight of the lens is usually shared between the cornea and the bulbar conjunctiva, avoiding excessive pressure on the corneal apex and ensuring an adequate peripheral lens clearance (Fig. 2.19). Furthermore, it is crucial to avoid any touch with the limbus, as it contains the stem cells, which are responsible for corneal epithelial replacement and wound healing. Thus, limbus insult may lead to serious contact lens complications such as the Limbal Stem Cell Deficiency, which courses with epithelial defects, corneal conjunctivalization, neovascularization, corneal scarring and chronic inflammation [40]. Fig 2.19. Corneo-scleral lens fitting in a keratoconus patient.The fluorescein pattern shows clearance beneath the center of the lens, with a smooth support on the apex of the cornea. The primary lens support is located in the bulbar conjunctiva, which, in this case, shows a reasonable fluorescein clearance. Excessive bearing on the conjunctiva must be avoided in order to elude a vessel tourniquet effect in this area. (Image Source: Centre Universitari de la Visió). 17 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 4. MATERIAL AND METHOD 4.1. DESCRIPTION OF THE SAMPLE AND STUDY DESIGN This retrospective study included patients who had undergone corneal topography with both Easygraph and Pentacam devices at the CUV (Centre Universitari de la Visió) clinic. The topography exams of 26 eyes (20 healthy and 6 keratoconus eyes) were searched in the CUV database. The inclusion criteria for the healthy group were (1) age between 18 and 40 years old, (2) no corneal alterations, (3) corneal astigmatism less than or equal to 2,50D and (4) both Easygraph and Pentacam topographies had to be reliable. On the other hand, the inclusion criteria for the keratoconus group were (1) age between 18 and 40 years old, (2) diagnosed with keratoconus, (3) without any other corneal alteration and (4) both Easygraph and Pentacam topographies had to be reliable. Other corneal ectasia forms, such as pellucid marginal degeneration or keratoglobus, were excluded from the study. 4.2. MATERIAL 4.2.1. Easygraph (1.76 Version) Easygraph (Oculus, Wetzlar, Germany) is a small cone, Placido-based corneal topographer (Fig 4.1). This device is commonly used in the optometry field because it is able to provide useful corneal information in the day-to-day optometrists work (e.g. for fitting soft or corneal RGP contact lenses). Moreover, it is relatively inexpensive compared with other sophisticated corneal topographer devices. The main technical features include a total of 22.000 analyzed corneal spots, a working distance of 40 mm from the eye’s patient and a total of 22 Placido rings. 24 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ Fig 4.1. Frontal and back view of Easygraph (Image Source: Centre Universitari de la Visió). 4.2.2. Pentacam HR Pentacam (Oculus, Wetzlar, Germany) is a corneal topographer based on the Scheimpflug imaging technique. It is provided with two rotatory cameras which are able to capture up to 50 images of the anterior eye segment (that is, cornea, limbus, anterior chamber, iris and a small portion of the anterior sclera) in 2 seconds. This device is rarely used for fitting contact lenses (a simpler corneal topographer is usually enough for fitting most of the contact lenses). However, it is commonly used in ophthalmology and for research purposes. Fig 4.2. Frontal and back view of Pentacam (Image Source: Centre Universitari de la Visió). 25 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 4.2.3. JR Screen Ruler Because of the Easygraph limitations encountered during the course of this study (see 4.3.2. Easygraph previous assessment), an application called JR Screen Ruler (downloaded from the internet) was used in order to obtain the corneal measures. Main features of JR Screen Ruler are described below: ●Available metric units: Centimetres, Inches, Pixels, Picas and “Custom” (Pixels per inch units). ●Color, size and transparency of the ruler may be modified. ●The ruler is able to rotate clockwise and counterclockwise, one degree at a time. ●The ruler can be moved to any position on the screen using the mouse or the computer keys. ●The ruler shows the horizontal (X) and vertical (Y) position coordinates of the mouse cursor, considering the upper left corner of the ruler as X=0 and Y=0 (Fig 4.3). ●The ruler shows a vertical and horizontal line that crosses at the mouse cursor (Fig 4.3). ●Red lines can be drawn on the ruler (Fig 4.4). Fig 4.3. JR Screen Ruler. The coordinates of the mouse cursor (X, Y) are shown at the left of the ruler. The horizontal and vertical grey lines go from the mouse cursor to the edges of the ruler. Fig 4.4. JR Screen Ruler. Lines can be drawn on the ruler (red line). To draw the line, the user only has to click on two different spots on the ruler. The application automatically draws the line that connects these two selected spots. 26 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 4.3. METHOD 4.3.1. Distribution of the sagittal height measurements In this study, we pretended to follow the sagittal height measurement distribution that Mas-Aixalà et al. proposed in his doctoral thesis [39]. In their study, measuring spots were spread across 3 corneal meridians (specifically, 0-180º, 45-225ºand 135-315º,Fig. 4.5). Thus, a total of 8 sagittal height measurements were obtained in each meridian. As shown in Fig 4.5, corneal sagittal heights in the vertical meridian (0-90º) were not assessed in this study. This is because researchers were unable to evaluate this meridian since the upper lid prevented the topography assessment of the upper area of the cornea. Fig 4.5. Corneal sagittal height measuring locations of the experimental KAKC lens design for keratoconus. The sagittal height measuring spots (D0, D1, D2and D3) were located at the junction of the different zones of the lens (that is, at the optical zone - curve 1, curve 1 - curve 2, curve 2 - peripheral curve and peripheral curve - edge lift junctions). Thus, lens zone diameters were first calculated in order to determine the position of the measuring spots. The diameters were calculated using the formulas that are shown in the picture. 27 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 4.3.2. Easygraph previous assessment Before we started collecting the corneal measures, the elevation map provided by Easygraph was first assessed. Two important conclusions were drawn from this previous evaluation: First, the Easygraph version that was available at the CUV clinic (at the moment of the study) was able to provide the corneal elevation value of any spot of the elevation map. The user only had to click the mouse button on any location of the map and the corneal elevation value for that particular spot was shown. However, the topograper did not show the location of the spot that the user was measuring (e.g. in the form of corneal coordinates). For this reason we needed a support app (JR Screen Ruler) that allowed the location of D0, D1, D2and D3during the measuring process with Easygraph. Second, the Easygraph elevation map only assessed the central and part of the paracentral zone of the cornea. Approximately, the topographer was only able to provide elevation data of the central 7.5 mm of the cornea. In the light of these results, it was decided that the peripheral D2and D3spots had to be excluded from our study, since the topographer limitations did not allow its measurement. Finally, we decided to establish a D0value of 6 mm and a D1value of 7.2 mm in all cases. Using this arrangement, D0spots were always located at 3 mm from the center of the cornea and D1spots were located at 3.6 mm (Fig 4.6). Fig 4.6. D0and D1positions in our study. The red asterisk represents the center of the cornea. 28 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 4.3.3. Measuring D0and D1with Pentacam The process we followed in our study in order to obtain the corneal sagittal height measurements from the Scheimpflug images are described in figures 4.7. to 4.12.: Fig 4.7. Step 1: Tracing the white-to-white line. First, the white-to-white line was drawn (blue line). This line links both sides of the sclero-corneal limbus. At this point, the option “Show pixel Edge'' was used in order to facilitate the location of the limbus in the Scheimpflug images. This option showed a red line above the corneal epithelium, which determined the spot where the cornea merges with the limbus. Fig 4.8. Step 2: Tracing a parallel line to white-to-white (part 1). In this step, the JR Ruler application was used to trace (or “copy”) the line drawn in the previous step, as it can be seen in the picture. 29 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ Fig 4.9. Step 3: Tracing a parallel line to white to white (part 2). Once the line was traced on the ruler, it was moved upward until that line was tangent to the apex of the cornea. In this position, a copy of the “ruler line” was traced on the Scheimpflug image. Fig 4.10. Step 4: Locating corneal apex and D0- D1spots. Zoom was used on Scheimpflug images in order to facilitate the location of the contact point between the blue line traced in the previous step (step 3) and the epithelium of the cornea. That spot was considered the corneal apex and, from there, ancillary lines were drawn in order to locate D0(ancillary line of 3000 µm length) and D1(ancillary line of 3600 µm length). 30 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ Fig 4.11. Step 5: Tracing the corneal sagittal height line. At this point, the ruler was rotated one degree at a time until it acquired the same inclination as the previously drawn line, as can be seen in the picture. Then, the corneal sagittal height line was drawn from the measuring spot to the epithelium using the vertical edge of the ruler as reference in order to draw the line as perpendicular as possible to the upper line. Finally, the length of the drawn sagittal line was recorded (in the image a D0value of 598 µm was found). Fig 4.12. Final view of all sagittal height measurements of a single meridian. The process had to be repeated in the other two remaining meridians of the cornea (obtaining a total of 12 sagittal height measurements per eye). 31 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 4.3.4. Measuring D0and D1with Easygraph Easygraph sagittal height measurements were obtained following the next steps: Step 1: Calibrating JR Screen Ruler. First, the ruler was displayed above the elevation map and its scale was calibrated using the Custom option. In our study, we always set a 1:2 Ruler scale compared with the topography scale. Therefore, each millimeter of the ruler was equivalent to 2 mm of the topography map. We used that scale configuration because it favoured the measuring process. Step 2: Calibrating Best Fit Sphere (BFS). Best fit sphere curvature radii and eccentricity were both changed to a value equal to 0 mm. With this particular arrangement, a flat BFS (being tangent to the center of the cornea) was achieved. The classic BFS provided by Easygraph and the flat BFS used in our study are depicted in Fig 4.13., in order to facilitate the reader’s understanding. Fig 4.13. Classic BFS provided by Easygraph and BFS used in our study. We assumed that sagittal measures of both devices (Pentacam and Easygraph) were directly comparable using this particular BFS arrangement. Step 3: Locating the measuring spot (D0or D1). First, the JR Screen Ruler was placed adjacent to the Topographer ruler. In our study, we always matched the number 2 of the JR Screen Ruler with the number 0 of the topographer ruler (therefore, number 2 was our ruler starting point for measuring). Using this arrangement, nasal D0spots (D0 0°, D0 45°and D 0 315°) were always located at 3.5 mm from the beginning of the ruler (notice that D0was located at 3 mm from the center of the cornea and we used a 2:1 ruler scale, therefore, D0was at 1.5 mm from the center of the cornea when was located with the JR Screen Ruler. Also, it is important to notice that we started measuring from number 2, therefore D0was located at 2 mm + 1.5 mm = 3.5 mm). On the other hand, temporal D0spots (D0 135°, D0 180°and D 0 225°) were always located at 0.5 mm from the beginning of the ruler (2 mm - 1.5 mm = 0.5 mm). 32 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ Using the same methodology, nasal D1spots (D1 0°, D1 45°and D1 315°) were found at 3.8 mm and temporal D1spots (D1 135°, D1 180°and D 1 225°) were found at 0.20 mm from the beginning of the ruler. Fig 4.14. Locating D0 0°spot. We used the ruler coordinates (in this case X = 3.50 mm since it is a nasal D0spot) and we also used the horizontal grey line that crosses the edges of the topography map (blue rectangle) in order to find the spot measures. Fig 4.15. Locating D0 45°spot. The ruler was properly rotated in the oblique measurements (45°, 135°, 225°and 315°). 33 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ Mean values of the sagittal height measurements are also shown in Fig 5.5 and Fig 5.6. It may be observed that the mean values obtained from Pentacam are slightly higher than the mean values obtained from Easygraph, in most of the cases (about 30 µm difference, approximately). The Mann-Whitney test confirmed that, as it could be suspected before the statistical analysis, there exists statistical differences between the data collected from both topographers, finding a p-value = 0,000 in both D0and D1cases. Specifically, the median values found for Easygraph were S0= 582 µm and S1= 841 µm whereas the median values found for Pentacam were S0= 610 µm and S1= 880 µm, being these differences statistically significant, as we stated above. Observing Fig 5.5 and Fig 5.6, it is clear that sagittal height measures obtained from the Keratoconus group are higher than measures obtained from the healthy group. As it was expected, the Kruskal-Wallis test found statistical differences between the median values of both groups. However, there was one case in which non statistical differences were found: Easygraph D1. In other words, we cannot establish that there were statistical differences between keratoconus and healthy D1values when they were determined with the Easygraph topographer. GROUP DEVICE D00° D045° D0135° D0180° D0225° D0315° Healthy Easygraph 579,1 581,2 580,3 580 579,5 577 Healthy Pentacam 600,3 604,5 596,8 593,5 604,3 608,8 KC Easygraph 640,8 625,2 620,8 629,7 673,2 675,5 KC Pentacam 680,8 679,2 658,3 655,8 663,3 695,8 Fig 5.5. D0mean values. Values are shown in micrometres (µm). GROUP DEVICE D10° D145° D1135° D1180° D1225° D1315° Healthy Easygraph 839,7 846,4 851 842,6 852,6 852,4 Healthy Pentacam 867,5 880,5 872,3 866,8 875,8 888 KC Easygraph 838,3 850,5 827 828,8 879,5 879 KC Pentacam 829,5 925 883,8 886,3 917,5 947,5 Fig 5.6. D1mean values. Values are shown in micrometres (µm). 40 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ The Bland-Altman plot (Fig 5.7) showed an acceptable agreement between measures obtained with Easygraph and Pentacam, since close to 95 % (94,5 %) of the data points lied within ± 1.96 SD of the mean difference-limits of agreement (283 points lied within the limits while 17 points lied outside). Fig 5.7. Bland-Altman plot. Only few data points lied outside the difference limits, showing significant agreement between Pentacam and Easygraph measurements. The correlation between Easygraph and Pentacam measures was also assessed with a regression analysis. Results showed a significant correlation between Easygraph and Pentacam measurements, finding a R2= 95,9% (Fig 5.8.). In addition, an Easygraph-Pentacam equation was also determined, finding the following equation: Pentacam SAG = 17,89 + 1,014*Easygraph SAG. 41 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ Fig 5.8. Linear regression between Pentacam and Easygraph measurements. Finally, curvature radii (R0and R1) of 4 KAKC contact lenses (2 for each topographer and 2 for each contact lens version) were calculated for each subject of the study (see 4.3.5. Lens curvature radii determination). From this data, mean R0and R1were determined in order to assess the radii differences between lenses calculated from Easygraph and lenses calculated from Pentacam. These mean values are shown below (Fig 5.9). DEVICE LENS DESIGN Mean R0 SD R0 Mean R1 SD R1 Easygraph Conventional 7,712 0,3977 7,866 0,3651 Pentacam Conventional 7,451 0,3749 7,629 0,3339 Easygraph Reverse geometry 7,893 0,4185 6,341 0,2572 Pentacam Reverse geometry 7,618 0,3937 6,220 0,2890 Fig 5.9. Mean R0, R1and Standard Deviation found in our study. Results showed that mean Pentacam-Easygraph radii differences in the conventional lens design were 0,261 mm for R0and 0,236 mm for R1whereas differences in the reverse geometry design were 0,275 mm for R0and 0,121 mm for R1. 42 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ The frequency distribution of the radii differences are shown in the following Histogram graphics: Fig 5.10. Histogram graphic of the R0radii differences (includes data of both conventional and reverse geometry lenses). Fig 5.11. Histogram graphic of the R1radii differences (includes data of both conventional and reverse geometry lenses). 43 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 6. DISCUSSION The Mann-Whitney test found statistical differences between the data collected from both topographers in all cases (D0and D1). These differences might be explained (at least in part) by the fact that the measures were obtained semi-manually from both Easygraph and Pentacam instruments. A significant level of agreement was found between the measures obtained with both topographers in the Bland-Altman plot. This result suggests that the new measurement method proposed in our study (sagittal height measurement with Easygraph) has provided sagittal height values that were comparable to the values provided by the current Pentacam “gold standard” method, with an estimated bias of -27.8 µm. However, we cannot establish that the two methods may be used interchangeably since, in our opinion, the differences within mean ± 1.96 SD (55.1 µm, approximately 10% of the full corneal thickness) might be clinically important. The fitted line plot also suggests that there is a significant agreement between instruments, finding a R2= 95,9%. If we observe the point distribution on the graphic, they generally follow the regression line, with only one point that appears to be an outlier. It may also be observed that the points are accumulated in two areas of the graphic, one covering lower sagittal values (approximately from 550 µm to 700 µm, which corresponds to the D0measures) and other covering higher sagittal values (approximately from 800 µm to 950 µm, which corresponds to the D1measures). It is worth mentioning that this specific point pattern is also seen in the Bland-Altman plot. As expected, statistical differences were found between keratoconus and healthy subjects, finding higher sagittal values in the keratoconus group. This is explained by the shape differences between normal (aspheric-shaped) and keratoconus corneas (cone-shaped and steeper in the apex). However, statistical differences were not found between both groups when D1was determined with Easygraph. This result was not expected and it could be explained by the Easygraph extrapolation system. In broad terms, the elevation map provided by Easygraph is built from true-measured corneal data as well as extrapolated data. True-measured data usually come from the central zone of the cornea whereas extrapolation is applied in areas where the measure was unachievable. In our opinion, the algorytm responsible for determining this extrapolated data is programmed to be effective in healthy corneas, but we cannot assume that this algorithm works accurately in irregular corneas. This fact might explain that statistical differences were found between the healthy and the keratoconus groups in D0(since it is located more centrally and true-measured data is more likely to be available) 44 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ whereas statistical differences were not found in D1(since it is located more peripherally and the extrapolation system is more likely to be needed). Therefore, we suggest that the Easygraph extrapolation algorithm might be the root cause of not finding statistical differences between the keratoconus and the healthy groups when measured with this instrument. Significant radii differences were found between contact lenses that were determined with each topographer (0,261 mm for R0and 0,236 mm for R1in the conventional design whereas 0,275 mm for R0and 0,121 mm for R1in the reverse geometry design). In our opinion, these radii differences are clinically significant, especially in normal cornea fittings, since 0.05 - 0.10 mm variations are enough to clinically change the patient’s fluorescein pattern. However, a higher radii variation (0.10 - 0.15 mm) is commonly required to clinically change keratoconus fittings. Consequently, radii differences that were found in our study might be less significant in these patients. Nevertheless, both histogram graphics and high rates of standard deviation that were found for R0and R1suggest that data were spread out from the mean values and, subsequently, results should be interpreted carefully. According to the results of this study, Easygraph seems to be too limited to determine all the parameters of the experimental contact lens proposed by Mas-Aixalà et al. in his doctoral thesis (at least the old Easygraph version that was available at the CUV clinic at the moment of the study). Perhaps, the current version of this topographer is able to provide enough extrapolated data for determining R2and R3. In this hypothetical scenario, future methodologies characterized by a more automatic measuring process (for both Easygraph and Pentacam instruments) could allow the interchangeably use of both instruments for fitting the KAKC experimental lens in keratoconus patients. As a final observation, we believe that an alternative option could be designing a lens trial set (e.g. composed of 20 lenses). Thus, optometrists would only require this trial set for determining the suitable lens parameters for the patient, as commonly happens with many other gas-permeable lens designs. 45 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 7. CONCLUSIONS The following conclusions can be drawn from the results and its interpretation: ●The current available contact lenses for the optical correction of keratoconus may provide numerous advantages but also some drawbacks to the patient. ●Easygraph seems to be too limited to determine all the parameters of the experimental contact lens because of its small measurement range (provides data of the central 7.5 mm of the cornea, approximately). ●The Easygraph 1.76 version is not able to provide the sagittal height value of any specific corneal location by itself. ●There exists statistical differences between the data collected from both topographers. Specifically, Pentacam has provided higher sagittal height values than Easygraph (about 30 µm difference, approximately). ●As expected, sagittal height values obtained from the keratoconus group were higher than measures obtained from the healthy group, due to the shape differences of the cornea. ●Both topographers cannot be used interchangeably when measuring the sagittal height of the cornea and/or determining the parameters of the experimental contact lens, at least using the methodology proposed in our study. ●Easygraph provides sagittal height values from both true corneal measurements and extrapolated data. This could be a handicap for fitting the experimental contact lens in keratoconus eyes since it is expected that extrapolation does not work accurately on irregular corneas. Further investigation is required in order to determine whether the Easygraph extrapolation algorytm is able to provide reliable sagittal height values in these patients. 46 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 8. LIMITATIONS OF THE STUDY AND FUTURE RESEARCH The findings of this study have to be seen in light of the following limitations: ●Few topographies of subjects with keratoconus were found in the CUV database. In our opinion, a larger keratoconus group was needed in order to conclude a valid research result. ●There is a lack of previous research studies on the topic. To the best of our knowledge, no studies have been conducted to assess the sagittal height of specific corneal locations using the Easygraph topographer and only one study has evaluated the sagittal height of the cornea using the Scheimpflug images. This limited the design of the study, since we were unable to read previous works in order to design our own study methodology. ●The method employed to collect the data was excessively observer dependent in both Easygraph and Pentacam topographers. In our opinion, a more automatic method would be more appropriate for collecting precise data. ●Easygraph did not allow the peripheral D2and D3measurement. This severely limited the assessment of the Easygraph topographer when determining the parameters of the experimental contact lens. Accordingly, we would like to propose the following suggestions for future studies: ●We suggest assessing the last version of the Easygraph topographer. As far as we know, this version is able to provide corneal sagittal height measurements automatically, not needing an external app such as the JR Screen Ruler. ●We suggest collecting the sagittal height data from the Pentacam elevation map instead of the Scheimpflug images. This could provide more reliable data to the study since the measurements would be obtained automatically. ●It would be interesting to study if any relationship exists between central and peripheral sagittal height values of both healthy and keratoconic corneas. This could provide further knowledge about the shape of the cornea and the changes that occur in keratoconus. All of which could help to improve the current experimental contact lens design for keratoconus. ●The Easygraph extrapolation system should be assessed in order to determine whether it is able to provide reliable sagittal height measurements in keratoconus eyes. 47 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ ●It is also necessary to conduct studies with a larger keratoconus sample in order to conclude a valid research result. ●Finally, we believe that an alternative option could be designing a lens trial set for fitting the experimental contact lens. In our opinion, the parameters of those lenses should be determined from a large keratoconus sample assessed with the Pentacam topographer. 48 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 9. BIBLIOGRAPHIC REFERENCES 1. J. H. Krachmer, R. S. Feder, M. W. Belin: Keratoconus and related noninflammatory corneal thinning disorders. Survey of Ophthalmology.28:293-322 1984. 2. Y. S. Rabinowitz: Keratoconus. Survey of Ophthalmology. 42:297-319 1998. 3. A. S. Jun, L. Cope, C. Speck: Subnormal cytokine profile in the tear fluid of keratoconus patients. PLOS ONE.6:e16437 2011. 4. I. Lema, T. Sobrino, J. A. Duran, D. Brea, E. Díez-Feijoo: Subclinical keratoconus and inflammatory molecules from tears. British Journal of Ophthalmology.93:820-824 2009. 5. A. Behndig, K. Karlsson, B. O. Johansson, T. Brännström, S. L. Marklund: Superoxide dismutase isoenzymes in the normal and diseased human cornea. Investigative Ophthalmology and Visual Science.42:2293-2296 2001. 6. D. R. Holland, N. Maeda, S. B. Hannush: Unilateral keratoconus. Incidence and quantitative topographic analysis. Ophthalmology.104:1409-1413 1997. 7. L. R. Lee, L. W. Hirst, G. Readshaw: Clinical detection of unilateral keratoconus. Australian and New Zealand Journal of Ophthalmology. 23:129-133 1995. 8. Y. S. Rabinowitz, A. B. Nesburn, P. J. McDonnell: Videokeratography of the fellow eye in unilateral keratoconus. Ophthalmology.100:181-186 1993. 9. Y. S. Rabinowitz, H. Yang, K. Rasheed, X. Li. Longitudinal analysis of the fellow eyes in unilateral keratoconus. Ophthalmology. 111:440-446 2004. 10. R. H. Kennedy, W. M. Bourne, J.A. Dyer. A 48-year clinical and epidemiologic study of keratoconus. American Journal of Ophthalmology. 101:267-273 1986. 11. W. Rahmen, S. Anwar. An unusual case of keratoconus. Journal of Pediatric Ophthalmology and Strabismus.43:373-475 2006. 12. M. Romero-Jiménez, J. Santodomingo-Rubido, J. Wolffsohn: Keratoconus: A review. Contact Lens Anterior Eye.33:157-166 2010. 49 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ TABLE CONTINUED ON NEXT PAGE. 56 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 57 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 58 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ TABLE CONTINUED ON NEXT PAGE. 59 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 60 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ TABLE CONTINUED ON NEXT PAGE. 61 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 62 Determination of corneal sagittas for contact lens fitting in Keratoconus ________________________________________________________________ 63