Canine-inspired unidirectional flows for improving memory effects in machine olfaction

Kim, Soohwan,Mukherjee, Sandeepan,Fonollosa Magrinyà, Jordi,Hu, David L.

Abstract

A dog's nose differs from a human's in that air does not change direction but flows in a unidirectional path from inlet to outlet. Previous simulations showed that unidirectional flow through a dog’s complex nasal passageways creates stagnant zones of trapped air. We hypothesize that these zones give the dog a “physical memory,” which it may use to compare recent odors to past ones. In this study, we conducted experiments with our previously built Gaseous Recognition Oscillatory Machine Integrating Technology (GROMIT) and performed corresponding simulations in two dimensions. We compared three settings: a control setting that mimics the bidirectional flow of the human nose; a short-circuit setting where odors exit before reaching the sensors; and a unidirectional configuration using a dedicated inlet and outlet that mimics the dog’s nose. After exposure to odors, the sensors in the unidirectional setting showed the slowest return to their baseline level, indicative of memory effects. Simulations showed that both short-circuit and unidirectional flows created trapped recirculation zones, which slowed the release of odors from the chamber. In the future, memory effects such as the ones found here may improve the sensitivity and utility of electronic noses.

Full text

Canine-inspired Unidirectional Flows for Improving Memory Effects in Machine Olfaction Soohwan Kim1*, Sandeepan Mukherjee1*, Jordi Fonollosa2,3,4, David L. Hu1,5 Schools of Mechanical Engineering1 and Biological Sciences5 Georgia Institute of Technology, Atlanta, GA 30332, USA 2 B2SLab, Departament d’Enginyeria de Sistemes, Autom2tica i Inform2tica Industrial, Universitat Polit4cnica de Catalunya, 08028 Barcelona, Spain. 3 Networking Biomedical Research Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Madrid, Spain. 4 Institut de Recerca Sant Joan de D<u, 08950 Esplugues de Llobregat, Spain. * These authors contributed equally Corresponding author: David L. Hu 801 Ferst Drive, MRDC 1308, Atlanta, GA 30332-0405 (404)894-0573 [email protected] Abstract In a dog’s nose, air flows unidirectionally from the nostrils’ inlet to its outlet. Previous simulations showed that unidirectional flow through a dog’s complex nasal passageways creates stagnant zones of trapped air. We hypothesize that these zones give the dog a “physical memory” which it may use to compare recent odors to past ones. In this study, we conducted experiments with our previously built Gaseous Recognition Oscillatory Machine Integrating Technology (GROMIT) and perform corresponding simulations in two dimensions. We compared three settings: a control setting that mimics the bidirectional flow of the human nose, a short-circuit setting where odors exit before reaching the sensors, and a unidirectional configuration using a dedicated inlet and outlet that most mimics the dog’s nose. After exposure to odors, the sensors in the unidirectional setting showed the slowest return to their baseline level, indicative of memory effects. Simulations showed that both short-circuit and unidirectional flows created trapped recirculation zones which slows the release of odors from the chamber. In the future, the memory effects such as the ones found here may improve the sensitivity and utility of electronic noses. 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 Introduction Most keen-scented mammals such as dogs sniff by rapidly inhaling and exhaling air in a periodic fashion. A dog’s unique nasal architecture, in particular a front-facing orifice for the fluid inhale and lateral orifice for the exhale, enables unidirectional airflow in the olfactory region. Such unidirectional airflow is thought to be a contributor to their keen sense of smell. Figure 1a shows a cross-sectional view of a dog’s nasal chambers, called the ethmoidal turbinates, which increase the surface area in contact with the air, warming and humidifying it. Flow entering the nose (in red) travels along a distinct pathway than the exiting flow (in blue). Simulations of a dog’s sniff have shown zones of recirculation and slow flow in the canine's olfactory pathways (Craven et al., 2007, Craven et al., 2010; Rygg et al., 2017). We hypothesize that these stagnant zones trap odors, giving sensors more time to identify the odors and compare them to the subsequent sniff. The objective of this study is to investigate if mimicking unidirectional airflow can enhance the performance of an artificial nose. Using an artificial nose allows for repeated controlled tests and the use of sensors to measure the local concentration of odor. In contrast to dogs, humans have a much simpler nasal architecture that can accommodates bidirectional air flow in their olfactory region. Unlike dogs, humans have only two orifices in their nose, rather than four. Humans sniff by drawing in odor-laden air using a comparatively long and steady inhalation. Exhalation generates flow along the same path, but in the opposite direction. Because flow changes directions along the same path, it has bi-directional rather than unidirectional flow. The lack of unidirectional flow is thought to be one of the reasons why humans do not sniff to identify odors (Craven et al., 2010). Artificial noses are machines designed to identify chemicals quickly and reliably by odor. They have use in detection of bombs, drugs, food ripeness, and food spoilage. Until such devices can be improved in sensitivity and specificity, however, many of these tasks will continue to be performed by trained humans or dogs. The first device to perform machine olfaction was built in 1964 using microelectrodes. In 1987, the term “electronic nose” was introduced to describe any device that detects odors using a sensor array (Persaud and Dodd, 1982; Gardner and Bartlett, 1994). Modern olfactometers involve a fan that directs steady flow to a sensory array. Staymates et al. (2016) designed a dog-nostril- inspired module that attaches to the fan and generates external airflow like that of a dog. The device improved odor acquisition and enhanced the performance of a commercial trace vapor detector compared to one that continuously drew in air. In 2021, we presented GROMIT, Gaseous Recognition Oscillatory Machine Integrating Technology, which used bellows to emulate the internal aerodynamics of a dog’s nose, specifically, the inhale and exhale of a dog’s sniff (Figure 1b, Spencer et al., 2021). While GROMIT mimicked some aspects of the pulsatile internal airflow patterns of a dog, it used bi-directional rather than unidirectional flow. The GROMIT system demonstrated tradeoffs in speed and sensitivity of ethanol detection. In this study, we will also ethanol vapor as our odor to be detected. Ethanol is easy to obtain, cheap, safe for human health, and causes no harm to the environment. It is commonly used for testing MOx sensors such as in an assistant personal robot to detect gas leakages (Palacín et al., 1957) and in closed-loop control of dielectric excitation of gas sensors (Sol2-Penafiel et al. 2022). 2 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 Materials and Methods Design Considerations The 2021 GROMIT design involved a bellows system that pumped air into an airflow chamber (Figure 1b, Spencer et al., 2021). Inside the chamber was the sensory array, and outside the device were electronics to control the air flow and read the sensors. As shown in Fig 1c, the airflow chamber initially had two orifices: on one side was the bellows, and the other a single hole for incoming airflow to enter and exit the chamber. We redesigned the airflow chamber so that GROMIT has three orifices: one for the bellows, and a distinct entrance and exit orifice, as seen in Figure 1d. A dog’s nose uses a clever valveless design to drive flow unidirectionally from the inlet to the outlet, but designing such a geometry was beyond the scope of this work. Instead, we manually opened and closed the orifices. One constraint for our design was that the volume of the airflow chamber should be equal to the volume of the bellows itself, which was 112 mL, to enable the system to be flushed out with each sniff. Another constraint was that the chamber should be airtight. Any crevices that remained were covered in epoxy to better seal in the air. The resulting chamber consisted of two pieces, one 3D-printed and the other a rectangular prism laser cut from acrylic, with the sidewalls holding the sensors. The overall design was easy to iterate upon and repair. Sniffing experiments GROMIT detects odor using three commercial mini-oxide (MOx) sensors (Figaro Engineering Inc. TGS series) (Figure 1c, d). A higher concentration of ethanol in the chamber generated a higher voltage reading from the sensors, measured in millivolts (mV). The MOx gas sensors are sensitive to a wide range of volatiles such as volatile organic compounds, carbon monoxide, methane, nitrogen dioxide, among others. We installed two TGS2602 sensors and one TGS2610 in the sensor chamber. The different sensitivity of the sensors to the targeted chemicals, coupled to machine olfaction, enabled a device that can detect a large variety of chemical compounds. We performed nine trials with GROMIT in three settings (the control, short-circuit, and unidirectional settings) shown in Figure 2. In all settings, the bellows, shown on the left, inhaled and exhaled air in a periodic fashion. The air chamber had two orifices, a large orifice opposite to the bellows and a small orifice adjacent to the bellows. The settings differed in the order in which the small and large orifices are valved open and shut. The “control” setting was how GROMIT was run in 2021 (Spencer et al., 2021). Here, the small orifice was closed, and the air traveled through the large orifice, which was kept open. The “short-circuit” setting only has the small orifice open. As a result, airflow travelled exclusively through the small orifice, effectively short-circuiting the system before it can reach the sensors. The “unidirectional” setting involved manual opening and closing of the two orifices. We synchronized the valving with the bellows so that inhales occurred through the large orifice and exhales through the small orifice. The consequence was that fluid flow travels unidirectionally from inlet to outlet. The unidirectional configuration was the focus of this study, and the other two settings were used as a comparison. Each trial involved about one to two minutes of measurements. For all trials, the bellows were run at a frequency of f=¿ 1/3 Hz. Consequently, the period of one cycle was 3 s. This was the highest frequency that could be run without stalling out the motor that drives the bellows. The volume of the ethanol sample was re-measured before each trial to ensure evaporation effects were negligible 3 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 Each trial began with a purge cycle, where the bellows were run for one minute without any ethanol sample then we begin recordings. For an initial 10 seconds, 40mL of 95% ethanol in a 50mL beaker was placed at the inlet. Then the ethanol sample was removed, and the bellows ran without any sample for another 30 seconds. Mathematical modeling The air chamber dimension was 152 × 57 × 20 mm. Considering the cross sections along its longest dimension, its hydraulic diameter Dh=4A P was 29.6 mm, where A is the cross-sectional area, and P is the perimeter of the cross-section. A stepper motor (Anaheim Automation Inc. 15Y202S-LW4) actuated the bellow to mimic the inhalation and exhalation of respiratory systems. The bellow consisted of an elastic annulus that started as a convex truncated cone and pushed into a concave cone. The cone had a large radius R of 38 mm, small radius r of 7.5 mm, and height h of 30 mm, with an associated volume Vbellow= ( 1/3 ) πh ( R2+Rr+r2 ) =¿ 56 mL. During an exhale, the conical bellows goes from concave to convex and thus pushes two cone volumes 2Vbellow during a half period (0.5 τ ), so the average flow rate during an exhale is Qaverage=¿ 74.7 mL/s. Dividing the flow rate by the cross-sectional area of the circular bellow orifice (diameter of 15.2 mm) yields the average velocity Ubellow = 0.41 m/s. We did not verify this speed with a flow sensor because only the order of magnitude is necessary for calculating dimensionless groups. For the kinematic viscosity of the air ν = 1.48×10-5 m2/s and the hydraulic diameter, we obtain the Reynolds number ℜ and Womersley number Wo : ReDh=Ubellow Dh ν (1) Wo=Dh √ πf 2ν (2) which produce R eDh=¿ 819 and Wo=¿ 5.6. The Reynolds number indicates the flow is near the turbulence regime where inertia dominates over viscosity. The Womersley number, which was originally derived to describe the cardiovascular flows (Womersley et al., 1955), represents the ratio between the transient inertial force and viscous force. An excessive Womersley number lowers the chance for the particles to strike the sensor surface, resulting in low signal. Previous investigators observed the biological Womersley number across animals, including pygmy, rabbit, dog, and deer, ranges from 0.2 to 2.5 (Spencer et al. 2021). We matched the Womersley number in GROMIT by having a larger hydraulic diameter and a smaller frequency than in dogs. Our total bellows volume of 112 mL was chosen to be at least the same order of magnitude as the inspiratory capacity of dogs (500-2500 mL, Donati et al., 2018) while keeping our device small and easy to use. To evaluate the effectiveness of GROMIT, we consider three metrics: the voltage drop, delay time, and residence time, illustrated in Fig 3. The voltage drop is defined as the absolute magnitude of the largest observed change in voltage from its baseline value. The baseline voltage is the average of the voltage reading when ethanol is introduced to GROMIT’s inlet. For all data, we report t = 0 as the time that ethanol is introduced. Furthermore, the initial voltage for all trials has been shifted to zero. Since we provide the same ethanol concentration for each setting, a higher voltage drop indicates more ethanol exposure to the sensor. The diagonal arrows show the location of the voltage drop for each case in Fig 3. The delay time is the time elapsed for the voltage drop to occur. A longer time delay results 4 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 in longer observed memory effects as ethanol remains trapped near the sensors. Residence time is the time that elapses before the sensor returns to within 20% of the baseline voltage. Desirable properties in a configuration are a large voltage drop, short delay time and long residence time. A larger memory effect is associated with a longer residence time. Memory effects are due the lingering particles of ethanol that remain in the chamber of the device even after the sample has been removed. Data collection and system operation were controlled by Arduino Uno microcontroller as described in Spencer et al. (2021). We wrote a MATLAB code to calculate the voltage drop, delay time, and residence time. We applied a median filter on the data to smooth it out using the sliding window method with a length of ten data points. Simulations To better understand the flow inside the camber, we conducted two-dimensional computational fluid dynamics (CFD) simulations to characterize the time course of the velocity field and ethanol concentration field. COMSOL Multiphysics was used to find the transient solutions of the incompressible turbulence flow using k-epsilon RANS (Reynolds-averaged Navier–Stokes) model. A typical timedependent nonlinear solver was used to solve the Navier-Stokes equations, and GMRES (Generalized Minimal Residual) solver, accelerated by a multigrid method, was used for the time marching method. A piecewise linear interpolation was used for the discretization. For incompressible Newtonian fluid flow, the Navier-Stokes equation and the continuity equation are expressed as follows: ρ ( ∂ui ∂t +uj⋅∂ui ∂x j ) =−∂ p ∂ xi +μ∂2ui ∂ xj∂xj +ρf i (3) ∂ui ∂xi =0 (4) where ρ is the density of the fluid, ui is the velocity component in corresponding direction, p is the pressure, μ is the dynamic viscosity, and fi is the external force component acting on the fluid. The term on the left-hand side represents the acceleration of the fluid, and the term on the right-hand side represents the forces acting on the fluid, including pressure, viscous forces, and external forces. K-epsilon (k-ε) turbulence model simulates mean flow characteristics for turbulent flow conditions in CFD. This model solves for two transport equations, which is equivalent to the Navier- Stokes equation. The two transported variables are the turbulent kinetic energy k and the rate of dissipation of turbulent kinetic energy ε . The standard k-ε model has two transport equations as follows (Launder and Spalding, 1983). For turbulent kinetic energy k , ρ ( ∂k ∂t +∂ ( k ui ) ∂xi ) =∂ ∂ xj [ μt σk ∂k ∂x j ] +2μtEij Eij−ρε (4) For dissipation rate ε , 5 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 ρ ( ∂ε ∂t +∂ ( ε ui ) ∂ xi ) =∂ ∂xj [ μt σε ∂ε ∂xj ] +C1ε ε k2μtEij Eij−C2ερε2 k (5) where Eij is the component of deformation rate, μt is the eddy viscosity ( ρ Cμk2/ε ). The k-ε model also contains adjustable constants σk , σε , Cμ , C1ε , and C2ε . Empirical data fitting for a variety of turbulent flows has led to the calculations of these constants. Below are the values we used from the experimental data (Wilcox, 1998). σk=1.0 , σε=1.3 , Cμ=0.09 , C1ε=1.44 , C2ε=1.92 (6) We recreated the GROMIT device in 2D computational field based on the top view of device with identical chamber dimensions and dimensionless numbers ( ℜ=¿ 819 and Wo=¿ 5.6). The flow simulations were conducted in two dimensions in a rectangular chamber with dimensions 152 mm × 20 mm and a tapered end towards the bellows. As in the experimental system, there are two outlets. We defined the inlet as the boundary connected to the bellow. The outlet boundary condition was set as an open boundary, or zero atmospheric pressure, while the inlet boundary condition is an oscillating normal inflow velocity with magnitude varying sinusoidally according to the input frequency of the trial. To match the average velocity at the bellow, u= ( π 2 ) Ubellow sin ( 2π τt ) was prescribed for the inflow velocity at the bellow. The walls of the chamber were set as no slip boundary conditions and the logarithmic law of the wall was configured to describe the turbulent behavior near the wall. While the bellow inhales or exhales the air, the outlets were set to be open boundary conditions in accordance with the timing of the setting considered. The air in the chamber was initially at rest. The system utilized a 1mm mesh size and time step of 0.01s. The transport of ethanol particles was also simulated using the Transport of Diluted Species interface in COMSOL, coupled with the velocity field obtained from the k-ε model. The massless particles follow the convection-diffusion equation given as ∂c ∂t =D∂2c ∂ xi∂ xi +ui ∂c ∂xi (6) where c is the concentration of the particles of interest, D is the diffusion coefficient of the particles, and ui is the velocity component in corresponding direction. The term on the left-hand side represents the rate of concentration change. On the right-hand side, the first term is transport due to the diffusion governed by the Fick’s law, and the second term is transport owing to fluid convection. We prescribed a no flux boundary condition for the wall while following the same open boundary conditions as turbulence model for the orifices depending on the treatment. The bellows boundary integrated the incoming particle flux over length and time after every inhale and pushed out the same moles of particle during exhale to emulate the transport from the bellow volume to the chamber. One of our assumptions is that the target odor is diffusive enough in air, so that it can leave the streamline and land on the sensor. As a measure of the diffusivity of an odor, the dimensionless Schmidt number Sc may be written 6 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 Sc=ν D (7) where ν is the kinematic viscosity of the air and D is the diffusion coefficient. In our case, the ethanol vapor in air typically has D = 1.0 × 10-5 m2/s. The corresponding Schmidt number becomes 1.5, which belongs to the diffusive regime ( Sc<¿ 4). Our scope of study is limited to the target particles within the diffusive regime. It would be necessary to use a different technique to capture large particles such as dust, since they do not diffuse sufficiently having higher Schmidt number ( Sc≫ 1, Cussler, L., 2009). Results We performed nine total experiments with GROMIT, with three experiments in each of three settings described in the methods section. Our focus was on the unidirectional flow setting, in which inflow comes through a dedicated inhale orifice and outflow goes through a separate exhale orifice, analogous to a dog’s nose. We averaged readings from each of three sensors and across trials. Figure 3 shows the time course of the sensor voltage. We offset the voltage so that the baseline voltage of each sensor is zero. Figure 4 shows the averaged metrics of interest, the voltage drop (a), and delay time and residence time (b). In these figures, ethanol was exposed to GROMIT from zero to ten seconds and then removed for the rest of the trial. We first consider the control and short-circuit setting, before turning our focus to the unidirectional setting. In the control setting, the sensors registered a swift voltage drop of 119 ± 55 mV. This voltage drop occurred at a time of 5 ± 1 s, which is faster than the short-circuit and unidirectional cases. After a 10-second exposure, the ethanol sample was removed from the inlet. Consequently, the voltage recovered to the baseline value with a residence time of 13 ± 15 seconds after the onset of ethanol, indicating low memory effects, as expected because the large orifice allows the chamber to be flushed clean by the bellows. As we will show in the simulations, the short-circuit configuration generates cavity flow, whose stagnant zone might prevent the odors from reaching the sensors. Accordingly, the incoming fluid does not flow as directly to the sensors as in the control case. We see the voltage drop of 158 ± 5 mV occurs at around a time of 34 ± 1 s, which is nearly six times slower than in the control setting. Moreover, a longer residence time of 46 ± 4 s is observed, indicating that the cavity flows are associated with memory effects. The unidirectional setting showed a slower and more drawn-out response than the previous settings. The voltage drop of 169 ± 76 mV occurred at 85 ± 27 s. The voltage drop was comparable to other settings. However, the delay time was the greatest across all treatments; it was 1,682% of control and 253% of short-circuit. The first voltage drop occurred at approximately 15 seconds as shown by the dotted arrow in the figure. Then the voltage did not return to baseline levels, but instead a second voltage drop occurred far after the ethanol sample was removed from the inlet. Finally, the signal recovered to the baseline after the residence time of 106 ± 8 s. This event was most likely a result of the bellows pushing some stagnant odorant-laden air over the sensors again. We conducted one-tailed t-Tests to evaluate statistical significance of the delay and residence times. The t-Test showed that the delay time of the unidirectional treatment was significantly higher than both the control (P = 0.0032) and the short-circuit case (P = 0.0142). Similarly, the unidirectional residence time difference was significantly larger than both the control (P = 0.0003) and the short-circuit 7 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 (P = 0.0017). The voltage drop did not show any significant differences between three treatments (P ≫ 0.05). Figure 5,6 show our computational results with a two-dimensional chamber of similar shape as our experiments. Figure 5a shows the internal velocity field during one cycle for each setting. Two moments were captured: inhalation (t = 0.75s) and exhalation (t = 2.25s). Air was sucked into the device at t = 0.75 s and as can be shown by the reversal of the arrows, it had the opposite flow direction at t = 2.25 s. We denote the locations of two sensors by the R and L symbols. These two positions were comparable to the sensor positions in the experiment. Since the walls have a no-slip boundary condition, the distance between the wall and the reported value was 0.5 mm. Note that the left sensor position was the midpoint of the two sensors at the bottom in Figure 2. During the exhalation, the diffuser generated flow separation and eddies near the walls. The control setting pushed the air across the sensors throughout both the inhale and exhale, as shown by the horizontal streamlines. The short-circuit setting maintained stagnation near the sensors during the entire cycle, which likely prevented the external odors from reaching the sensors. The unidirectional case pushed air to the sensors only during intake. Consequently, introduced odor particles remained circulating in the chamber. Figure 5b show the time course of the air velocity in the y-direction for the two sensors. Later we will report odor concentration, but for now velocity indicates whether there is flow across the sensors or not. Since flow is necessary to bring odorants, we use it as a simple metric for the sensor’s ability to read odors. The control setting showed the highest fluctuations in velocity, which is consistent with the velocity fields in Figure 5a. Velocity fluctuation was the lowest in the short-circuit setting in the first cycle, but the recirculation in short-circuit was strong enough to have comparable speed to the unidirectional case in later cycles. This implies the possibility for particles to be transported by advection in the short-circuit case. In the unidirectional configuration, the velocity fluctuation was the lowest at the locations of the sensors, which may contribute to the memory effect. We next simulated the concentration of ethanal in the chamber. During ethanol exposure, a concentration of 1 mol/m3 boundary condition was used for the incoming air for an initial three cycles, which had a comparable duration of exposure (9 s) to the experiment (10 s). After the exposure, the system operated without influx of ethanol for an additional 17 cycles, which is equivalent to 60 seconds of operation in total. Figure 6a shows the simulated ethanol concentration field at the same moments as Figure 5a. Red color indicates a high concentration of ethanol. During inhalation (t = 0.75 s), the ethanol entered the inlet of each setting and the bellow also inhaled a portion. During exhalation (t = 2.25 s), the bellow exhaled its contents, driving flow towards the respective outlet for each setting. Note that the control case flushed out ethanol during the exhale, with only some ethanol remaining near the walls of the diffuser. We expected the short-circuit case to introduce little ethanol into the chamber. That was mostly the case, but diffusive transport still entrained ethanol into the circulation region on the right. The unidirectional case had an identical concentration to the control during the inhale. However, the exhale to the nearby outlet permitted a much higher concentration of particles to resides in the chamber, demonstrating the memory effect. We integrated the concentration across the chamber area to find the total amount of ethanol per unit depth. If sensors were equipped all over the chamber, this average concentration could be measured and compared to experiments. However, in our experiments, sensors were only placed on the right-hand 8 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 side of the chamber. Figure 6b shows the time course of ethanol during 20 cycles, equivalent to 60 s. The initial three cycles were exposed to an incoming ethanol-laden flow of 1 mol/m3 of concentration. The control case (in red) showed the largest fluctuation in concentration throughout the cycles, followed by the unidirectional case (in green). Both these settings were the most responsive: they increased to their peak concentration within a single cycle. In comparison, the short circuit flow had the slowest ethanol entrainment into the chamber: it took nearly three cycles to obtain the same level of ethanol as the other settings. After the ethanol was removed, the unidirectional and control case showed the most rapid decay to zero concentration, followed by the short circuit case. Thus, the simulations show that the short circuit setting had the highest memory effect when considering the entire chamber. Discussion In this study, we considered the memory effect—the ability of systems to maintain previous odors —over subsequent sniffs. We hypothesize that this ability is advantageous to animals because it would facilitate comparison of current to previous sniffs. The ability of a system to hold its memory was affected by the timing of the openings of the orifice and their size and position. In both the short-circuit and unidirectional flow settings, exhaled air is pushed towards the large orifice, which is blocked. The small orifice on the side requires fluid to change direction and has a small hole. Thus, odor-laden air faces infinite resistance exiting the large orifice, and high resistance exiting the small orifice. This resistance generates the ensuing stagnation zones, which causes some of the odorant to remain within the chamber and continue to interact with the sensors. The longer the sample is exposed to the sensors, the stronger and more extended the voltage change. Indeed, in our experiments, we saw that the unidirectional setting had the longest delay and residence time. Figure 3a shows that the control configuration starts to decrease during ethanol exposure. In this configuration we expect a voltage drop during the inhale, followed by a voltage recovery during the subsequent exhale. Indeed, simulation show this this while ethanol is present. However, our experiments do not show these oscillations in voltage. The sensors have a small metallic housing to prevent physical damage. We surmise that the sensor housing smooths these oscillations. We were surprised that the simulations (Fig 6b) showed that the short circuit configuration had the longest decay time, and thus the largest memory effect. From the experiments, we expected the unidirectional setting to have the largest memory effect. The difference might be explained by sensor sensitivity. The short-circuit case has the strongest memory effect if the sensor’s limit of detection is above ~2 mol/m and the unidirectional case has the strongest memory effect if the limit of detection is above ~7 mol/m. Therefore, characterizing the sensor’s sensitivity would help to rationalize the experimental and computational results. In nature, the observed memory effect allows animals to scan for gradients in odor across different locations or make comparisons of mixtures of odor from one location to another. The ability to retain the sample and expose sensors for longer duration should also help electronic noses to detect odor concentrations near their limit of detection. We discuss briefly the limitations of our study. Our tests only use ethanol, whereas in nature, odors will be combinations of different chemicals. Additionally, our device does not have a liquid coating analogous to the mucus of the biological nose which would require even further time for odorant molecules to diffuse through. In natural noses, different odors land on different portions of the olfactory 9 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 Figure 4: Measurements of the voltage drop (a), and the delay time and the residence time (b) for each flow setting. The voltage drops were statistically different. The unidirectional flow showed significantly longer delay time and residence time. 16 461 462 463 464 Figure 5: a. Simulations showing two snapshots of the velocity field for three flow settings. Air is inhaled at t = 0.75 s, changes flow direction, and exhaled at t = 2.25 s. A cycle is 3 seconds long. b. Velocity in the y-direction at two points marked with red circles in part a where sensors are located. The left wall sensor (left panel) and right wall sensor (right panel) are each located 60 mm above the bottom of the chamber. Red is control, blue is the short-circuit setting, and green is the unidirectional setting. 17 465 466 467 468 469 470 471 472 Figure 6: a. Simulations of the ethanol concentration field for the three flow settings at two points in time, t = 0.75 s, and t = 2.25 s. White arrows show streamlines. b. The number of moles of ethanol per unit depth for different treatments. Red is the control, blue is the short-circuit setting, and green is the unidirectional setting. CFD Simulation Movies Movie 1: Velocity field of the Control setting (case 1) Movie 2: Velocity field of the Short Circuit Settings (case 2) 18 473 474 475 476 477 478 479 480 481 Movie 3: Velocity field of the Unidirectional Setting (case 3) Movie 4: Concentration field of the Control setting (case 1) Movie 5: Concentration field of the Short Circuit Settings (case 2) Movie 6: Concentration field of the Unidirectional Setting (case 3) 19 482 483 484 485 486