scieee AI-readable full text Open interactive document viewer

Ammoniun removal from wastewater by liquid-liquid membrane contactors

Alcaraz Segura, Aurora

Abstract

Removal of ammonia from wastewater generated in a waste treatment plant by a membrane contactor was studied at lab scale. The treated wastewater will be applied in the Hydrogen and Oxygen production by electrolysis via renewable energies. The aim of this study relies on fulfill the process requirements in the electrolysis, since the water used in the electrolysis process must be almost pure water due to efficiency process of Hydrogen and Oxygen production decreases with the ions in the dissolution. The residual ammonium concentration of the aqueous stream feeding the membrane distillation step ranging between 1 to 5 ppm is not removed and arrives to the electrolysis step generating an increase in the conductivity. So the use of a liquid-liquid membrane contactor is proposed to reduce ammonium (NH+4) concentration before membranes distillation step. The experimental set-up was performed by a contactor (Liqui-cel X30 HF (Celgard, USA)) which works in close and open loop mode configuration. In close circuit, it was used a tank of 10 liters to storage ammonium solution and in open circuit it was used 25 liters as initial ammonium volume. A pump (Cole Parmer instrument) was used to feed the contactor from the tank. An aqueous ammonium solution with a low concentration is in the inner side of the membrane contactor (Lumen) and sulphuric acid solution goes in the outside of the membrane contactor (Shell). The pH plays a very important role in the chemical equilibrium; for that reason is motorized during the experiments. On the other hand, it has been carried out the simulation of a mathematical model used by various authors to validate the experimental results by COMSOL Multiphysics program

Full text

Màster en Recerca en Enginyeria de Processos Químics Ammoniun removal from wastewater by liquid-liquid membrane contactors Author: Aurora Alcaraz Segura Supervisor: César Valderrama Universidad Politécnica de Catalunya December 2012 Ammonium removal from wastewater by liquid-liquid membrane contactors 1 Abstract Removal of ammonia from wastewater generated in a waste treatment plant by a membrane contactor was studied at lab scale. The treated wastewater will be applied in the Hydrogen and Oxygen production by electrolysis via renewable energies. The aim of this study relies on fulfill the process requirements in the electrolysis, since the water used in the electrolysis process must be almost pure water due to efficiency process of Hydrogen and Oxygen production decreases with the ions in the dissolution. The residual ammonium concentration of the aqueous stream feeding the membrane distillation step ranging between 1 to 5 ppm is not removed and arrives to the electrolysis step generating an increase in the conductivity. So the use of a liquid-liquid membrane contactor is proposed to reduce ammonium (NH+4) concentration before membranes distillation step. The experimental set-up was performed by a contactor (Liqui-cel X30 HF (Celgard, USA)) which works in close and open loop mode configuration. In close circuit, it was used a tank of 10 liters to storage ammonium solution and in open circuit it was used 25 liters as initial ammonium volume. A pump (Cole Parmer instrument) was used to feed the contactor from the tank. An aqueous ammonium solution with a low concentration is in the inner side of the membrane contactor (Lumen) and sulphuric acid solution goes in the outside of the membrane contactor (Shell). The pH plays a very important role in the chemical equilibrium; for that reason is motorized during the experiments. On the other hand, it has been carried out the simulation of a mathematical model used by various authors to validate the experimental results by COMSOL Multiphysics program. Index 1. Index of Tables .............................................................................................................. 5 2. Index of Figures ............................................................................................................ 7 3. Notations ....................................................................................................................... 9 4. Introduction ................................................................................................................. 11 4.1 Aqueous solution chemistry of the system NH3 - NH4+ - H2O ............................ 12 5. Membrane processes for the removal of ammonium and ammonia ....................... 14 5.1 Introduction .......................................................................................................... 14 5.2 Membrane process .............................................................................................. 14 6. Membrane contactors ................................................................................................. 16 6.1 Hollow fiber membrane modules ........................................................................ 18 6.1.1 Longitudinal flow modules .......................................................................... 18 6.1.2 Cross-flow modules ..................................................................................... 18 6.1.3 Coiled modules ............................................................................................. 19 7. Applications of membranes contactors ................................................................... 20 8. Membrane contactors for ammonium removal ......................................................... 25 8.1 Mass transfer in membrane contactors ............................................................. 25 8.2 Mathematical model development for the removal of ammonium from aqueous solution using contactors .............................................................................................. 27 8.2.1 Close loop operation mode .......................................................................... 27 8.2.2 Open loop operation mode .......................................................................... 33 9. Objectives and Methodology ..................................................................................... 33 9.1 Objectives ............................................................................................................ 33 9.2 Methodology ........................................................................................................ 34 9.2.1 Reagents ....................................................................................................... 34 9.2.2 Membrane contactors .................................................................................. 34 9.2.3 Experimental procedure ............................................................................... 35 9.2.4 Monitoring protocol ...................................................................................... 37 10. Results and discussion .......................................................................................... 39 10.1 Results and discussion for close loop operation mode ................................... 42 10.2 Results and discussion for open loop operation mode .................................... 47 11. Conclusions............................................................................................................. 56 12. Annex ....................................................................................................................... 57 12.1 Annex 1. Summary of the experimental results ................................................. 58 12.2 Annex 2. Graphics of experimental results ........................................................ 59 12.3 Annex 3. Poster exhibited in Milan COMSOL Congress in October 2012 ........ 61 12.4 Annex 4. . Paper exhibited in Milan COMSOL Congress in October 2012 ....... 62 13. References ............................................................................................................... 71 Ammonium removal from wastewater by liquid-liquid membrane contactors 5 1. Index of Tables Table 1. Membrane process ................................................................................................ 15 Table 2 Advantages and disadvantages of membrane contactors. ...................................... 17 Table 3. Specifications of the hollow fiber membrane contactor ........................................... 34 Table 4. Operation conditions in the experiments ................................................................ 35 Table 5.Summary of the experiments at conditions evaluated ............................................. 38 Table 6. Model equations and boundary conditions ............................................................. 39 Table 7. Initial values of parameters to be estimated ........................................................... 40 Table 8. Nominal values of membrane contactor parameters .............................................. 41 Table 9. Experimental results and RMSD with variable pH in close loop configuration with flow rate 0.26 l/min and initial concentration of ammonium of 15 ppm .................................. 43 Table 10. Experimental results and RMSD with variable initial concentration in close loop configuration with flow rate 0.26 l/min and pH 10.4 .............................................................. 44 Table 11. Experimental results and RMSD with variable flow rate in close loop configuration with initial concentration of ammonium of 15 ppm and pH 10.1 ............................................ 46 Table 12. Optimal work conditions in close loop configuration ............................................. 46 Table 13. Experimental results and RMSD with variable pH in open loop configuration with flow rate 0.26 l/min and initial concentration of ammonium 5 ppm........................................ 48 Table 14. Experimental results and RMSD with variable flow rate in open loop configuration with initial concentration of ammonium of 5 ppm and pH 9.9................................................ 50 Table 15. Experimental results and RMSD with variable initial concentration of ammonium in open loop configuration ........................................................................................................ 51 Table 16. Optimal work conditions in open loop configuration .............................................. 51 Table 17. Experimental results and RMSD with variable initial concentration of ammonium in open loop configuration with wastewater.............................................................................. 54 6 Ammonium removal from wastewater by liquid-liquid membrane contactors Table 18. Parameters estimated for close and open loop configuration model ..................... 54 Table 19. Characteristics parameters for close and open loop configuration model ............. 55 Ammonium removal from wastewater by liquid-liquid membrane contactors 7 2. Index of Figures Figure 1. Pilot plant developed for Greenlysis project (CETaqua) ........................................ 11 Figure 2. Equilibrium Ammonia-Ammonium dependent of pH .............................................. 13 Figure 3. Membrane contactor ............................................................................................. 16 Figure 4. Longitudinal flow membrane contactor module scheme ........................................ 18 Figure 5. Cross-flow membrane contactor module scheme.................................................. 19 Figure 6. Coiled membrane contactor module scheme ........................................................ 20 Figure 7. Principle of pertraction .......................................................................................... 22 Figure 8. Principle of emulsion pertaction ............................................................................ 23 Figure 9. Principle membrane gas absortion ........................................................................ 24 Figure 10. Transport steps for separation of NH3 molecules through the HFMC ................. 25 Figure 11. Principle of the extraction process ...................................................................... 26 Figure 12. Experimental setup ............................................................................................. 27 Figure 13. Concentration profile for the species j at a particular time when it moves from lumen side towards shell side through a microporous hydrophobic membrane .................... 32 Figure 14. a) Cross section of a membrane module showing the fibers. b) Hollow fiber with the transport phenomena. c) Membrane contactor. d) Side view of the entrance to the hollow fibers. ................................................................................................................................... 35 Figure 15. Membrane contactor operated by liquid-liquid extraction (Close loop configuration) ............................................................................................................................................ 36 Figure 16. Membrane contactor for the removal of dissolved ammonia (Open loop configuration) ....................................................................................................................... 36 Figure 17. Influence of feed solution pH on the fractional removal in the close loop configuration, with flow rate 0.26 l/min and initial ammonium concentration of 15 ppm. Comparison between simulated values and experimental data. ........................................... 42 14 Ammonium removal from wastewater by liquid-liquid membrane contactors Due to use of this compound to industrial, domestic and agriculture sector, ammonia is one of the major inorganic pollutants in the water. Then the removal of this substance is due to two main reasons (Jorgense and Wheatley, 2003; Moazed, 2008): Its extreme toxicity to marine life (concentrations below 0.01 ppm have negative effects on fish, while 0.1 ppm can be lethal to other species) (Mandowara and Bhattacharya, 2011). It can be bio-oxidized by nitrifying organisms to nitrites and nitrates. This project also takes into account a third reason for removal. As has been mentioned above, the ammonia impact in higher conductivity which is not desired for electrolysis step in the hydrolysis process for producing hydrogen and oxygen, which makes necessary to remove this compound. 5. Membrane processes for the removal of ammonium and ammonia 5.1 Introduction Several techniques are available for the removal of dissolved ammonia, such as air stripping, break-point chlorination, selective ion exchange, biological nitrification and denitrification and adsorption (Sarioglu, 2005). Removal by conventional extraction or stripping processes may not be suitable for low-concentration wastewater. Break-point chlorination suffers from several disadvantages including large treatment volume, associated risk, difficulty of pH control, and high chemical costs. The ion-exchange process requires expensive organic resins and large quantities of eluent solution (Sarioglu, 2005). Biological nitrification and denitrification are slow processes and require large treatment vessels. Therefore, most of the available treatment processes are not particularly effective at low concentrations. Some of the advances made in membrane processes in last two decades allow considering this technique as potential attractive for ammonia removal. 5.2 Membrane process Commercially, membrane filtration has a great acceptance as an important step in many of the process in several industries, as well as in water purification (Scott, 1998). Very specific separations have been obtained at ambient temperature with no phase change which makes membrane filtration a cost-effective separation method compared to others such as vacuum Ammonium removal from wastewater by liquid-liquid membrane contactors 15 filtration, and spray drying. The hydrostatic pressure is most often the driving force, but can also be electrical potential, concentration gradient, or temperature. The processes collected in Table 1 represent the majority of commercial membrane separation technologies that could be used for NH3 / NH4+ removal: Table 1. Membrane process (Baker, 2000) However, a number of processes are still in the laboratory or early commercial stage and may yet become important. One of this processes are membrane contactors. In the membrane separation processes the membrane acts as a selective barrier allowing relatively free passage of one component while retaining another. In membrane contactors the membrane function is to provide an interface between two phases but not to control the rate of passage of permeates across the membrane (Baker, 2000). Due to many advantages offered by these devices, contactors are considered as a potential technology for ammonia removal from water. 16 Ammonium removal from wastewater by liquid-liquid membrane contactors 6. Membrane contactors Hollow fiber membrane contactors (HFMC) have been used to remove volatile compounds from water and wastewater. The hollow fibers used are commonly microporous and hydrophobic (Lee et al., 2003). In this process, the feed and stripping solution are flowing on either side of a membrane. Membrane contactors are divided in two parts: an internal side (Lumen) and an external side (Shell). Since the membrane is hydrophobic, it prevents aqueous solution, which has higher surface tension, to penetrate the gas-filled pores. The volatile compounds will volatilize from the feed, diffuse through the gas-filled membrane pores, and react with the stripping solution (Zhu et al., 2005). In Figure 3 is shown a typical configuration of membrane contactor: Figure 3. Membrane contactor (Gabelman, and Hwangb, 1999) Several theoretical studies have been carried out to understand the mechanism of gas removal using a hollow fiber membrane contactor and a variety of mathematical models have been developed. The focus of most of the studies has been on ammonia (NH3) and carbon dioxide (CO2), which are the common impurities present in industrial wastewater effluents and gas emissions respectively (Agrahari et al., 2012). Different types of membrane such as symmetric hydrophobic porous membranes or asymmetric membranes with ultra-thin layers can be used as a gas–liquid membrane contactor (Atchariyawut, et al., 2006; Albrecht et al., 2005). In both cases the membrane must be able to separate the contacting fluids. Typical membranes used are prepared from hydrophobic polymer materials with a high porosity. Among various hydrophobic polymers as polypropylene (PP), polyethylene(PE), polytetrafluoroethylene (PTFE) and Polyvinylidene fluoride (PVDF), which are the most popular membrane materials (Mansourizadeh and Ismael, 2009). PVDF membranes have Ammonium removal from wastewater by liquid-liquid membrane contactors 17 excellent chemical and thermal resistance which makes them suitable for most of the corrosive chemicals and organic compounds such as acids, alkaline, oxidant and halogens. The main advantages and disadvantages of hollow fibers contactors are summarized on Table 2. Table 2 Advantages and disadvantages of membrane contactors. (Baker, 2000) 18 Ammonium removal from wastewater by liquid-liquid membrane contactors 6.1 Hollow fiber membrane modules 6.1.1 Longitudinal flow modules In these modules, the gas and liquid phases flow in parallel to each other on the opposite side of the fibers (Figure 4). The flows can be co-current or counter-current. Most of the researches on the membrane gas absorption in laboratory scale have conducted on this kind of membrane module (Kim and Yang, 2000; Lee et al, 2001; Dindore et al., 2004; Yang and Cussler, 1986) studied and discussed the construction of the parallel and cross-flow modules. They reported the results of experiments made with these modules, and described the mechanism responsible for controlling the mass transfer in the various cases. Finally, they discussed the correlations that can be inferred from their experiments, and compare these with correlations previously reported for analogous heat and mass transfer problems. Their discussion provides a basis for designing hollow fiber membrane modules for contacting both gases and liquids in other situations. Figure 4. Longitudinal flow membrane contactor module scheme The simplicity in manufacturing, well known fluid dynamics in shell and tube side and easiness of mass transfer estimation are the advantages of this module, while the main disadvantages is the moderate efficiency in mass transfer compared with the cross-flow module (Mansourizadeh and Ismael, 2009). 6.1.2 Cross-flow modules In general, cross-flow operation of hollow fiber membrane contactors is preferred as it offers several advantages such as higher mass transfer coefficients, minimized shell side channeling and lower shell side pressure drop as compared to the parallel flow contactors. Physical gas absorption in a rectangular cross-flow hollow fiber gas–liquid membrane contactor has been discussed in detail by Dindore and Versteeg (2005). The performance of different parallel and cross-flow gas–liquid membrane contactors based on the equal flow per membrane area and equal flow per module volume and found that in both cases cross-flow membrane modules were more effective as compared to parallel flow modules. Details of the configuration of both types of modules are described in Figure 5. Ammonium removal from wastewater by liquid-liquid membrane contactors 19 Figure 5. Cross-flow membrane contactor module scheme (Dindore and Versteeg, 2005) 6.1.3 Coiled modules Recently, more attention is paid to the coiled modules for the ultrafiltration and nanofiltration membrane applications (Manno et al., 1998; Ghogomu et al., 2001; Mallubhotla et al., 1999). In this module curved channels are used to create secondary flow in fluid, so that the involved flow and transfer process are intensified. One important advantage of coiled module over others is its capability of simultaneous improvement on mass transfer in both lumen and shell side. Liu et al. (2005) prepared coiled hollow fiber membrane modules and examined their mass transfer performances for stripping dissolved oxygen from water. It was found that, compared with the conventional module, the mass transfer in both lumen and shell side of the coiled hollow fiber module could be remarkably enhanced. The improvements in mass transfer can be attributed to the created secondary flows (known as Dean Vortices) inside coiled fiber and the promoted turbulence on the shell. However, the number of studies on this area is rare. Figure 6 describes a coiled membrane contactor module. 20 Ammonium removal from wastewater by liquid-liquid membrane contactors Figure 6. Coiled membrane contactor module scheme (Liu et al, 2005) 7. Applications of membranes contactors Several researchers have carried out simulation studies of the degasification of water via convective diffusion using membrane contactors (Mandowara and Bhattacharya, 2009; Kieffer et al., 2008; Al-Marzouqi et al., 2008; Lee et al., 2001). Mandowara and Bhattacharya (2009) simulated ammonia removal by a vacuum application on the shell side and obtained concentration profiles. Kieffer et al. (2008) used computational fluid dynamics to numerically study mass transfer in a liquid-liquid-phase membrane contactor, and they observed a clear separation between the reaction and mixing zones. Al-Marzouqi et al. (2008) modeled the chemical absorption of CO2 in Monoethanolamine (MEA) solvent using PP membrane contactors; they considered both radial and axial diffusion under the condition of complete wetting. Lee et al. (2001) studied the removal of CO2 in a hollow fiber membrane contactor using aqueous potassium carbonate; they derived and numerically solved coupled nonlinear partial differential equations and also reported the optimal absorbent flow rate. Keshavarz et al. (2008) developed a mathematical model for membrane contactors operated under nonwet or partially wetted conditions during the simultaneous absorption of carbon dioxide and hydrogen sulphide in diethanolamine (DEA) solution. Bottino et al. (2008) experimentally and numerically studied CO2 removal from a gas stream using aqueous monoethanolamine as an extract phase. Different commercial polypropylene capillary membranes in a membrane contactor and found the CO2 removal efficiency were used. The experimental results were in good agreement with the predicted results. Malek et al. (1996) evaluated and studied microporous hollow-fiber membrane modules operated under partially wetted conditions. The nonlinear partial differential equations were solved using an orthogonal collocation method. The experimental results found were in good agreement with the modeling results. Ammonium removal from wastewater by liquid-liquid membrane contactors 21 McDermott et al. (2007) studied the vacuum-assisted removal of volatile and semi-volatile organic contaminants from water using hollow-fiber-based membrane contactors. They used a hybrid numerical-analytical approach and investigated the main factors controlling the removal characteristics, e.g., the Henry’s law coefficient, gas-side diffusion resistance, and aqueous diffusion limitation. Although it is difficult to introduce new technologies in industry there is still a large demand for new improved processes, especially in the field of separation technology. Stringent demands are put onto these new separation technologies in order to compete with the existing proven technologies and in order to meet stricter product quality requirements, environmental legislation, energy efficiency demands and last but not least needs for cost reduction (Klaassen et al., 2005). In order to meet these ever increasing needs there is a tendency to combine processes to a hybrid process. In a membrane contactor membrane separation is not only combined with an phase contacting process like extraction or absorption but both processes are fully integrated and incorporated into one piece of equipment. In this way advantages of both processes can be fully exploited (Klaassen et al, 2005). The membrane offers a flexible modular efficient device with a low volume and weight so that it can be easily integrated in existing installations. The extraction or absorption process can offer a very high selectivity and a high driving force for transport even at very low concentrations. Applications of membrane contactors are of interest for the chemical, petrochemical, pharmaceutical and galvanic industry for both water and gas treatment as end of pipe technology but also for product recovery and as integrated process solution (Klaassen et al., 2008). The industrial reference installations, in the field of pertraction, emulsion pertraction and membrane gas absorption, help to gain confidence of end users in the membrane contactor technology. 22 Ammonium removal from wastewater by liquid-liquid membrane contactors Pertraction technology Pertraction is a non-dispersive membrane based liquid–liquid extraction process. Nonpolar organic substances such as aromatics or chlorinated hydrocarbons can be recovered from process or wastewater flows by pertraction. The organic components are removed from the water by extraction into an organic extractant, which is immiscible with water. The extractant is flowing at one side of the membrane and the water phase at the other side. The role of the membrane is to keep the phases separated and to provide a suitable interface between the two phases. The membrane itself has no selectivity. The process selectivity must come from the extractant. The interface between wastewater and extractant is immobilized using a hydrophobic microporous hollow fiber membrane by means of a small trans-membrane pressure gradient (0.1 bar) (Kiani et al., 1984; Klassen et al., 1994b, Klaassen, 1998), as can be seen in Figure 7. Contrary to conventional extraction processes there is no direct mixing of extractant in the wastewater stream. Figure 7. Principle of pertraction Pertraction is especially suitable for removal of hydrophobic organic compounds like aromatic and aliphatic organics, chlorinated solvents (e.g., carbon tetrachloride, chloroform, tetrachloroethene and trichloroethene), PCB’s, di- and tri-chlorobenzene, pesticides and higher polycyclic hydrocarbons (Klaassen et al, 2005). Water streams containing these hydrocarbons can be found at many places: Effluents/process streams from pharmaceutical, off shore, automotive, paint, petrochemical and chemical-plants. Water originating from tank cleaning and tank storage. Effluents from garages dry cleaning and wood preservation. Contaminated ground water. Landfill leachate from sites containing chemical wastes. Ammonium removal from wastewater by liquid-liquid membrane contactors 23 Emulsion pertraction technology Emulsion pertraction is a combined extraction and regeneration process suitable for selective removal of heavy metals like copper, zinc, iron, chromium, cadmium or lead from aqueous solutions. The heavy metals can be recovered in a concentrated solution. Lifetime extension of bath liquids is an industrial application for emulsion pertraction. The principle of emulsion pertraction is also used by Commodore Separation Technologies for the recovery of Cr(VI) from waste water (Ho and Poddar, 2001). Water phase is kept apart from the emulsion phase by a hydrophobic microporous membrane. Emulsion pertraction is a process evolved from a combination of permeation through membranes and solvent extraction. (Klaassen et al., 1996). The emulsion phase consists of an organic solvent with a dissolved extractant as continuous phase with aqueous droplets of strip liquid dispersed in it. In Figure 8 it can see the principle of emulsion pertraction. The metal to be removed from the water phase is bound by the extractant present in the pores of the membrane. At the other side of the membrane the strip liquid continuously regenerates the extractant. In this way an optimal driving force for transport is maintained in the membrane contactor. The strip liquid is dispersed in the organic phase. There is no need to make this dispersion very suitable because the hydrophobic nature of the membrane keeps the waste water and aqueous strip liquid always separated. Figure 8. Principle of emulsion pertaction 30 Ammonium removal from wastewater by liquid-liquid membrane contactors Equation 14 shows that the diffusion of ammonia at the exit of the lumen (in Z-direction) to be negligible in comparison to its movement in the same direction due to flow. 4. At r = R, all Z and t TR p k r C D g a g poreg Rr j j int, , (Eq. 15) It can be seen that the flux of ammonia in aqueous phase equals the flux of the gaseous ammonia diffused through the pore as defines equation 15. The concentration of ammonia at the pore exit is assumed to be negligible. This is because an instantaneous reaction between acid and ammonia takes place at the pore exit. Additionally mass transfer coefficient inside the pore, kg, pore (m/s) can be defined as: b Dk porecaporeg ,,, (Eq. 16) Where Da, c, pore diffusivity of ammonia (m2·s-1) ε porosity of the membrane (dimensionless) tortuosity of the pore (dimensionless) b membrane thickness (m) This correlation was estimated by Mandowara and Battacharya (2009), where the tortuosity is given by (Bottino et al., 2008): 2 1 (Eq. 17) Diffusivity is calculated ( poreca D,, ) by: airaporeakporeca DDD ,,,,, 111 (Eq. 18) Ammonium removal from wastewater by liquid-liquid membrane contactors 31 Where Da,c,pore diffusivity of ammonia in the pore (m2·s-1) Dk,a, pore Knudsen diffusion (m2·s-1) Da,ai diffusivity of ammonia in the air (m2·s-1) Further, the Knudsen diffusion poreak D,, is given by 2/1 ,, 8 3a gpore poreak M TRd D (Eq. 19) Where dpore diameter of pore (m) Rg universal gas constant (J·mol-1·K-1) T temperature (K) Ma molecular weight of ammonia (g·mol-1) As previously defined, Cj is the concentration of ammonia and ammonium ions (mol·m-3): 43 NHNHCj (Eq. 20) Where 3 NH concentration of ammonia (mol·m-3) 4 NH concentration of ammonium (mol·m-3) In the other hand, at the liquid-gas interface located at the pore interface (Figure 13), Henry’s law may be applicable (Tan et al., 2006): int 3 int, NHHP a a g (Eq. 21) Where Ha Henry’s constant (Pa ·m3·mol-1) [NH3]int concentration of ammonia at liquid-gas interface (mol·m-3) 32 Ammonium removal from wastewater by liquid-liquid membrane contactors Figure 13. Concentration profile for the species j at a particular time when it moves from lumen side towards shell side through a microporous hydrophobic membrane (Mandowara and Bhattacharya, 2011) As explained in section 1, in aqueous solution equilibrium is established between dissolved ammonia gas and ammonium ions. A substantial fraction remains in the molecular form in solution. Under the assumption of uniform mixing, the mass balance equation can be written kLZj kQCQC dt dC Vtan, tan (Eq. 24) Initial condition: at t = 0 Ctank = Co (Eq. 25) To calculate the fractional removal of ammonia at time t in the tank: 0 tan )( 1C tC k (Eq. 26) Ammonium removal from wastewater by liquid-liquid membrane contactors 33 8.2.2 Open loop operation mode For open loop operation configuration was used the same model but boundary conditions were modified: 1. At steady state in the Eq. 9 0 t Cj (Eq. 26) 2. At Z = 0; all r and t Cj, Z=0 = Ctank (Eq. 27) In open loop operation mode the initial ammonia concentration is the same that the concentration tank. 9. Objectives and Methodology 9.1 Objectives The aim of this master project is the elimination of ammonia from the stream entering the Membranes distillation in Greenlysis pilot plant. For this purpose liquid-liquid contactors will used considering the advantages offered by this technology compared to conventional techniques as has been summarized in state of the art. The main objective is to investigate and evaluate the hollow fiber membrane contactors performance for ammonia removal from aqueous solutions under different processing conditions and to define the operational parameters necessary to remove ammonia efficiently. The parameters to be evaluated are Initial concentrations of the ammonia and sulfuric acid solutions the pH of the ammonia feed solution the flow-rate feed stream Use of different types of water: Tap water, MilliQ and wastewater from the pilot plant. Modeling the ammonium removal by membrane contactors by numerical solution of the governing equations. 34 Ammonium removal from wastewater by liquid-liquid membrane contactors 9.2 Methodology 9.2.1 Reagents The feeding solution was prepared by dissolving ammonium chloride in 10 L of water for concentrations between 5 and 15 ppm. NaOH solutions were used to achieve pH values higher than the usual value of pKa and shift the equilibrium to the predominant free molecular NH3. To keep constant pH value during all experimental time a borax buffer was used. The receiving solution was prepared dissolving 5 ml of H2SO4 98-99% v/v in 5 L of water. 9.2.2 Membrane contactors A laboratory-scale membrane contactor with polypropylene microporous hollow fibers from Liqui-Cel Company 2.5x8 inch was used. Details on the specifications of this module are collected in Table 3. Table 3. Specifications of the hollow fiber membrane contactor (Ashrafizadeh, 2010) Ammonium removal from wastewater by liquid-liquid membrane contactors 35 Figure 14 shows the internal structure of the membrane contactor. Figure 14. a) Cross section of a membrane module showing the fibers. b) Hollow fiber with the transport phenomena. c) Membrane contactor. d) Side view of the entrance to the hollow fibers. (Licon et al, 2012) 9.2.3 Experimental procedure The operating conditions of the close and open loop mode have been summarized in Table 4. Parameter Interval of values Unit Temperature 18-22 ºC Flow rate 0.16-0.26 l/min pH feed solution 9.27-10.4 - pH receiving solution 1.88-2 - Ammonia concentration in the feed 5-25 ppm Table 4. Operation conditions in the experiments 36 Ammonium removal from wastewater by liquid-liquid membrane contactors Experimental configurations: Figure 15. Membrane contactor operated by liquid-liquid extraction (Close loop configuration) (Mandowara and Bhattacharya, 2011) Figure 15 shows the setup for ammonia removal in close loop configuration. The ammonia feed solution is pumped through the lumen of the hollow-fiber membrane, while the stripping solution containing sulfuric acid is pumped into the shell side of the hollow-fiber membrane. Both solutions are recycled to their respective reservoirs (Licon et al, 2012) Figure 16. Membrane contactor for the removal of dissolved ammonia (Open loop configuration) (Mandowara and Bhattacharya, 2009) Figure 16 shows the setup for ammonia removal in open loop configuration. The process is similar, but the ammonia feed solution is not recycled. At the end of the experiment, the shell-side flow and the tube-side flow were stopped. The system was properly shut down and thoroughly cleaned by passing deionized water through both sides to remove the remaining solution. Ammonium removal from wastewater by liquid-liquid membrane contactors 37 9.2.4 Monitoring protocol The procedure for sampling in closed circuit was as follows: 1. At regular time intervals (10 minutes) 5mL samples were taken from the tank of feed solution. In total, 18 samples were collected by each experiment.. 2. The pH was measured by pH meter GLP22 Crison, Spain. 3. The samples were prepared for determined the ammonia concentration by ion exchange chromatography. The procedure for sampling in open circuit was as follows: 1. For the first experiments in open loop configuration, samples were taken every 5 minutes, obtaining 21 samples for each experiment. Once evolution was determined, the samples were taken every 10 minutes, reducing the number of samples to 10-13 for experiment depending on the flow rate. 2. The pH was measured by pH meter GLP22 Crison, Spain. 3. The samples were prepared for determined the ammonia concentration by ion exchange chromatography. 38 Ammonium removal from wastewater by liquid-liquid membrane contactors All the experimental conditions are summarized in the Table 5. Table 5.Summary of the experiments at conditions evaluated Experiment H2SO4NH4 +H2SO4NH4 + 1 5 10 2 7,3 0,26 8 Closed loop No No 2 5 10 2 10,4 0,26 5 Closed loop Yes Yes 3 5 10 1,88 9,2 0,26 15 Closed loop No Yes 4 5 10 1,97 10,4 0,26 15 Closed loop Yes Yes 5 5 10 2,06 9,8 0,26 15 Closed loop Yes Yes 6 5 10 1,88 10,1 0,26 15 Closed loop Yes Yes 7 5 10 1,86 10,1 0,61 15 Closed loop Yes Yes 810 25 1,92 9,9 0,26 5 Open loop No Yes 910 25 1,85 10,5 0,26 5 Open loop No Yes 10 10 25 1,95 9,9 0,41 5 Open loop No Yes 11 10 25 1,9 9,9 0,15 5 Open loop No Yes 12 10 25 1,81 9,9 0,26 10 Open loop No Yes 13 10 25 1,83 9,5 0,26 10 Open loop No Yes 14 10 25 1,82 9,8 0,26 7,8 Open loop No Yes 15 10 25 1,89 9,8 0,26 12,3 Open loop No Yes 16 10 25 1,77 9,8 0,26 24,3 Open loop No Yes Wastewater Buffer Type of circuit [NH4 +] (ppm) Flow rate (l/min) pH in tank Deionized Water NaOH 2M Tap water Tank Volume (L) Conditions Ammonium removal from wastewater by liquid-liquid membrane contactors 39 10. Results and discussion The evolution of the different parameters evaluated on each experiment is collected in Annex 1. The quantification of the efficiency (% removal NH4+) of the liquid-liquid membrane contactors on ammonia removal was calculated by using equation 28: 100)(% )0( )()0( 4 4 44 tNH tNHtNH C CC NHremoval (Eq. 28) Where )0( 4tNH C is the total ammonium concentration at t=o )( 4tNH C is the total ammonium concentration at time (t) Simulation studies were carried out for the removal of ammonia from water via membrane contactor using COMSOL software. In section 8 the model equations were explained for close and open loop configuration. For both modes, was used the equation 9 for describes the mass balance inside the lumen and using different boundary conditions for each type of circuit. Table 6 collects the mass transfer equation (equation 5) and the boundary conditions for close and open loop configuration: Mass transfer equation 2 2 1 Z C r C r rr D Z C U t Cjj j j z j Boundary conditions Close loop configuration Open loop configuration 0 0r j r C 0 t Cj kZj CC tan0, kZj CC tan0, 0 2 2 LZ j jZ C D TR p k r C D g a g poreg Rr j j int, , Table 6. Model equations and boundary conditions 46 Ammonium removal from wastewater by liquid-liquid membrane contactors [NH4+] (ppm) pH (NH4+) Type of circuit 15 10.1 Close loop Experiment Flow rate (l/min) % Removal Removal Time (min) RMSD (%) 6 0.26 100 150 5.60 7 0.61 100 120 6.80 Table 11. Experimental results and RMSD with variable flow rate in close loop configuration with initial concentration of ammonium of 15 ppm and pH 10.1 According to the obtained results it is possible to define the optimal experimental conditions for ammonium removal in close loop configuration. These conditions are summarized in Table 12. Close loop configuration pH [NH4+] Flow rate (l/min) Optimal conditions >9.3 <10.5 0.61 Table 12. Optimal work conditions in close loop configuration All experiments of close loop configuration are summarized in the Annex 2. Ammonium removal from wastewater by liquid-liquid membrane contactors 47 10.2 Results and discussion for open loop operation mode Based on the results obtained in closed circuit experiments, in open loop configuration were performed in order to evaluate the influence of pH, initial concentration and flow rate in the ammonium removal. The experiments in open loop configuration were performed by using deionized water and wastewater from the pilot plant. The most of the experiments with deionized water were performed in order to optimize the experimental conditions in open loop configuration. Then, considering these conditions were carried out the experimental with wastewater from the plant to achieve maximum ammonium removal. Experiment results by using Deionized water The first parameter studied in open loop configuration was the influence of feed solution pH. In close loop configuration, it was observed that when it was worked with a pH values below the pKa the removal efficiency was lower. So in the experiments in open loop were worked with a pH values over the pKa. It was evaluated the influence of this parameter in the range of pH from 9.9 to 10.5. Both experiments performed with a pH value over the pKa and it was observed removal efficiencies above the 90%. Then, the following experiments were carried out at pH values from 9.5 - 10, considering that for pH values above 10 the elimination is similar than pH values under 10 as can be seen in Figure 20. Figure 20. Influence of feed solution pH on the variation in fractional removal in the open loop configuration with Q = 0.26 l/min and initial concentration of ammonium 5 ppm. Experimental values 48 Ammonium removal from wastewater by liquid-liquid membrane contactors The experimental conditions and the results in open loop configuration with flow rate (0.26 l/min) and ammonia concentration (5 mg/l) removal ratio of ammonium achieved values of 91-92 % as can be seen in Table 13. The root-mean-square deviation (RMSD) which can be seen in Table 13 belongs to the experimental data deviate from the mathematical model for the experiments compared. Flow rate (l/min) [NH4+] (ppm) Type of circuit 0.26 5 Open loop Experiment pH (NH4+) % Removal Removal Time (min) RMSD (%) 8 9.9 92 105 2.70 9 10.5 91 105 Table 13. Experimental results and RMSD with variable pH in open loop configuration with flow rate 0.26 l/min and initial concentration of ammonium 5 ppm The influence of flow rate in the ammonium removal efficiency in open loop configuration is shown in Figure 21. The experiments were performed with pH 9.9 and initial concentration of ammonia of 5 ppm. The behavior observed was the decreases ammonia removal when the flow rate increases. This is due to increment of residential time inside the membrane contactor. ¸ Figure 21. Influence of flow rate on the variation in fractional removal in the open loop configuration with pH 9.9 and initial concentration of ammonium 5 ppm. Experimental values Ammonium removal from wastewater by liquid-liquid membrane contactors 49 Figure 22 shows the concentration at the outlet of the membrane contactor at the end of the experiment and the mathematical model. It can be seen that the model prediction fit properly the experimental data. However and slightly deviation was observed at in higher flow rates. Figure 22. Influence of flow rate on the variation in fractional removal in the open loop configuration with pH 9.9 and initial concentration of ammonium 5 ppm. Comparison between simulated values and experimental data. Table 14 collects the experimental conditions and the results in open loop configuration when flow rate varies when pH (9.9) and ammonia initial concentration (5 mg/l) were keep constant. The removal ratio of ammonium achieved values around 98 % for the lowest flow rate and 83% for the maximum. The deviation respect to the model is lower than 5%. Simulated Q (m3/s) Ctank/Co 50 Ammonium removal from wastewater by liquid-liquid membrane contactors pH (NH4+) [NH4+] (ppm) Type of circuit 9.9 5 Open loop Experiment Flow rate (l/min) % Removal Removal Time (min) RMSD (%) 11 0.16 98 100 2.29 8 0.26 92 105 10 0.42 83 60 Table 14. Experimental results and RMSD with variable flow rate in open loop configuration with initial concentration of ammonium of 5 ppm and pH 9.9 The influence of initial concentration of ammonium has been seen in Figure 23. The experiments have been performed with a constant flow rate (0.26 l/min) and pH of 9.9.The experimental results of higher initial concentration of ammonium does not show a clear tendency, but it was observed at the end of the experiment that the removal efficiency is higher (92%) for the 5 ppm of initial concentration. Then, in open loop configuration, the influence of the initial concentration in the removal process is a key parameter to be considered. Figure 23. Influence of initial concentration on the variation in fractional removal in the open loop configuration with pH 9.9 and Q = 0.26 l/min. Experimental values Ammonium removal from wastewater by liquid-liquid membrane contactors 51 The increase of concentration from 5 mg/l to 10 mg/l at constant pH and flow rate decreases the removal efficiency from 92% to 88% as can be seen in Table 15. The root-mean-square deviations (RMSD) which also are summarized in Table 15 showed values below 5% which indicates that model prediction fit properly the experimental data. pH (NH4+) Flow rate (l/min) Type of circuit 9.9 0.26 Open loop Experiment [NH4+] (ppm) % Removal Removal Time (min) RMSD (%) 8 5 92 105 3.04 12 10 88 110 Table 15. Experimental results and RMSD with variable initial concentration of ammonium in open loop configuration The optimal parameters for ammonium removal in open loop configuration it can be seen in Table 16. Open loop configuration pH [NH4+] Flow rate (l/min) Optimal conditions >9.3 <10 0.16 Table 16. Optimal work conditions in open loop configuration As was observed in open loop configuration, the optimum pH value should be above the pKa. On the other hand, the flow rate, in this case, should below compared to close loop configuration, in order to increase the residence time and then the removal of ammonium is favored. 52 Ammonium removal from wastewater by liquid-liquid membrane contactors Experiment results by using Wastewater Once the optimal parameters for the efficiency of ammonium removal were determined the pilot plant wastewater was used in the following experiments. The pH of the feed solution was the optimum (9.3 - 10), while the flow used was 0.26 l/min although the optimum flow is lower, the difference in the removal of ammonium was not significant as reported in Figure 24 and additionally the experimental time is reduced. The parameter evaluated in these experiments was the initial concentration of ammonia, which is a requirement from the pilot plant operation and it is due to the variability in the concentration of different substances in solution which depends on several parameters (operating, season, etc.). The ammonium concentration in the outlet stream as a function of time with initial feed concentration varying from 7.8-24.3 mg/l is shown in Figure 24. For the same initial volume (25 l), ammonia removal decreases with the ammonia concentration increases. Figure 24. Influence of initial concentration on the variation in fractional removal in the open loop configuration with wastewater with Q = 0.26 l/min and pH 9.8. Experimental values Ammonium removal from wastewater by liquid-liquid membrane contactors 53 The concentration at the outlet of the membrane contactor at the end of the experiment and the mathematical model prediction are shown in Figure 25. It can be observed that model description is quite good when compared to the experimental data and an slightly deviation is observed at higher flow rate as was observed previously in section 10.1. The general deviation of this parameter can be seen in Table 17. Figure 25. Influence of flow rate on the variation in fractional removal in open loop configuration with Q = 0.26 l/min and pH 9.8. Comparison between simulated values and experimental data. Table 17 shows the experimental conditions and the results of the experiments with wastewater. The increase of concentration from 7.8 mg/l to 24.3 mg/l at constant pH and flow rate decreases the removal efficiency from 97% to 66%. The deviation with the mathematical model is >5%. One reason may be the existence of other species in solution because it was worked wastewater from the plant and the mathematical model was designed for the deionized water. Ctank (ppm) 54 Ammonium removal from wastewater by liquid-liquid membrane contactors pH (NH4+) Flow rate (l/min) Type of circuit 9.8 0.26 Open loop Experiment [NH4+] (ppm) % Removal Removal Time (min) RMSD (%) 14 7.8 97 90 7.80 15 12.3 82 100 16 24.3 66 97 Table 17. Experimental results and RMSD with variable initial concentration of ammonium in open loop configuration with wastewater All experimental results of open loop configuration can be seen in the Annex 2. Finally, it is shown in Table 19 the diffusivity coefficient in the pore (Da, c, pore) and the mass transfer coefficient were calculated with equations 16-19 using the estimated parameters obtained by non-lineal least squares method for close and open loop configuration (Table 18). Close loop Open loop Inner radius of the lumen, di (m) 1.18·10-04 1.23*10-4 Length of the fibre, L (m) 0.178 0.180 Diffusivity in water, Dj (m2/s) 2.06·10-09 2.12*10-9 Diffusivity in air, Da,air (m2/s) 1.92·10-05 2.05 *10-5 Dissociation constant of ammonia, Kb 1.64·10-05 1.735*10-5 Table 18. Parameters estimated for close and open loop configuration model Ammonium removal from wastewater by liquid-liquid membrane contactors 55 Close loop Open loop Diffusivity coefficient, Da, c ,pore (m2/s) 3.56· 10-6 3.74· 10-6 Mass transfer coefficient, kg, pore (m/s) 7.59·10-3 9.25 · 10-3 Table 19. Characteristics parameters for close and open loop configuration model 62 Ammonium removal from wastewater by liquid-liquid membrane contactors 12.4 Annex 4. . Paper exhibited in Milan COMSOL Congress in October 2012 Ammonia Removal from Water by Liquid-Liquid Membrane Contactor under Closed Loop Regime. E. Licon*1, S. Casas1, A. Alcaraz1, J.L. Cortina1, C. Valderrama1 1Universitat Politècnica de Catalunya, Barcelona, Spain *Corresponding author: Av. Diagonal 647 Edif. H 4th floor Barcelona, Spain 08028, [email protected] Abstract: Ammonia separation from water by a membrane contactor was simulated on transient state and compared with experimental data. Aqueous low concentrated solution of ammonium with high pH has been pumped inside a hydrophobic hollow fiber (lumen), sulfuric acid solution in the outside part and the feeding solutions are in closed loop configuration. In order to simulate the separation process, the model equations were developed considering radial-axial diffusion and convection in the lumen with a well-developed parabolic velocity profile. The model proposed shows minimal deviations when is compared against experimental data. This study shows that the most important parameters to control during the operation are the flow rate and the pH, mainly the last one, due to high dependence in chemical equilibrium of ammonium reaction to ammonia. Keywords: Ammonia removal, Membrane contactor, recirculation. 1. Introduction In this Study, water of a waste water treatment plant was used to remove ammonium by a liquid-liquid membrane contactor. This technology will be applied in the Hydrogen and Oxygen production by electrolysis via renewable energies, an outline of the process is shown in Appendix. The aim of this work relies on fulfill the process requirements in the electrolysis, since the efficiency of this step is inversely proportionally to conductivity. The ammonia concentration before membrane distillation step is usually between 1-5 ppm with not variations after this process. Then to use a liquid-liquid membrane contactor is proposed to reduce ammonium (NH+4) concentration before Membranes distillation step. 1.1 Ammonia-Ammonium equilibrium Ammonia is a colorless gas with a characteristic odor, very soluble in water. Its aqueous solutions are alkaline and have a corrosive effect in front to metals and tissue. Ammonia in water exists in Ammonium removal from wastewater by liquid-liquid membrane contactors 63 free and ionic forms under equilibrium as is shown in equation 1: (1) Figure 1 shows the predominant species for the ammonium equilibrium in water at different values of pH. For values below the pKa (9.3), ion ammonium is greater than ammonia. When pH is higher than the pKa, we found ammonia as predominant compound. Ammonia reacts with OH-ions present in the water, leading to gaseous ammonia molecule NH3. This gas pass through the hydrophobic membrane porous and reacts with an acid solution, where it is immediately dissolved as is shown in Figure 2-b. Since the membrane is hydrophobic, it prevents passage of feed aqueous solution through the pores and the pores are filled with air. Figure 1. Dependence of the Ammonia-Ammonium equilibrium with respect to pH. Figure 2. a) Cross section of a membrane module showing the fibers. b) Hollow fiber with the transport phenomena. c) Membrane contactor. d) Side view of the entrance to the hollow fibers. 2. Experimental 2.1 Materials The hydrophobic membrane contactor HFMC, (Liqui-Cel X30HF, Celgard, USA)., consists on hollow fibers, its properties are given in the Appendix (Table 1). The reagents used were ammonium chloride, sodium hydroxide to increase the pH of the dissolution, sulfuric acid (H2SO4 98% v/v) in the receiving compartment and borax as a buffer for maintain the pH in the feeding tank. 2.2 Set-up and procedure Aqueous solutions of NH3 were prepared by dissolving ammonium chloride in water for concentrations between 5 and 15 ppm, which will be referred as feeding solutions. The pH of the feed solutions was set higher than the usual value of pKa with )()( 42 )( 3aqaq aq OHNHOHNH 64 Ammonium removal from wastewater by liquid-liquid membrane contactors NaOH. Borax buffer has been used to keep the pH. The acid solution was prepared dissolving 5 ml of H2SO4 in 5 L of water. The concentration of dissolved NH3 in the water was measured by Ion Chromatography System (ICS-1000 Dionex, USA). The solution pH was measured by pH meter (pH meter GLP22 Crison, Spain). Figure 3 shows the experimental set-up used in the present study. It consisted on the HFMC module, two peristaltic pumps and two tanks, one for the ammonium solution and the other for the receiving solution. Figure 3. Experimental setup. The feed was delivered inside the hollow fiber (lumen) with different flow rates from a 10L tank containing aqueous NH4+ solution and was continuously recycled. In the other hand, the acid solution contained in a 5 L tank was delivered in the outside of the fibers inside the HFMC (shell) side of the module at constant flow rate in a countercurrent mode and was continuously recycled. Different conditions of pH, flow rate and initial concentration were tested. At regular time intervals of 10 min, samples of 20ml were taken from the feed tank by opening. Then each sample was analyzed by chromatography system. At the end of the experiment, both flows were stopped. The system was properly shut down and cleaned by passing DI water through both sides to remove the remaining solution. 3. Equations Following assumptions that have been made for some authors1-4, it has been considered: unsteady state and isothermal conditions, Henry's law is applicable for feed-membrane interface, no pore blockage occurs, the feed aqueous solution do not fills the membrane pores, the reaction of ammonia with the sulfuric acid is instantaneous and always occurs in excess. Flow rates of both ammonia solution and sulfuric acid are constant and Feed tank operates at the perfect mixing mode. The transport of both ammonia and ammonium ions in the lumen is expressed through a convective-diffusive equation: Ammonium removal from wastewater by liquid-liquid membrane contactors 65 jjjj jRCDCU t C2 ~ (2) where Cj is concentration of ammonia and ammonium ions (mol·m-3), D is diffusivity of the component in water (m2·s-1), Rj is the rate of generation due to the chemical reaction (mol·s-1·m-3), U is the velocity vector (m·s-1). In this process there is no chemical reaction in the lumen side, so the symmetry assumed inside the lumen is cylindrical. Further, Ur (Radial velocity), which is due to the diffusion of ammonia in the radial direction, also becomes zero. This is because the rate of diffusion of ammonia in water is negligible and the flow is in the Z direction. Now, the equation can be modified as follows: (3) The velocity distribution in the fiber under laminar flow conditions can be written as: 2 12)( hf zr r UrU (4) r is radial coordinate (m) and rhf is radius of the fiber. Defining to be the average velocity of the fluid inside the lumen: 2 hf rN Q U (5) Q is the flow rate (m3/s) and N is the number of fibers in the HFMC. Once defined the equations for the mass balance within fiber, the boundary conditions are: (6) (7) TR p k r C D g a g poreg rr j j hf int, , (8) It can be seen that the flux of ammonia in aqueous phase equals the flux of the gaseous ammonia diffused through the pore as defines equation (8). For determinate the equation (8) must be defined the mass transfer coefficient inside the pore (m/s): (9) Da,c,pore is diffusivity of ammonia (m2·s-1), ε is porosity of the membrane, b is membrane thickness (m) and is tortuosity of the pore given by: 2 2 1 Z C r C r rr D Z C U t Cjj j j z j U kZj CC tan0, 0 0r j r C b Dk porecaporeg ,,, 66 Ammonium removal from wastewater by liquid-liquid membrane contactors (10) Diffusivity of ammonia in the pore is calculated by: (11) Dk,a, pore is Knudsen diffusion (m2·s-1), Da,air is diffusivity of ammonia in the air (m2·s-1). Further, the Knudsen diffusion is given by: (12) dpore is diameter of pore (m),. Rg is universal gas constant (J·mol-1·K-1), T is temperature (K) and Ma is molecular weight of ammonia (g·mol-1). As previously defined, Cj is the concentration of ammonia and ammonium ions (mol·m- 3): 43 NHNHCj (13) Where [NH3] is concentration of ammonia (mol·m-3) and [NH4+] is concentration of ammonium. On the other hand, at the liquid-gas interface located at the pore interface, Henry’s law may be applicable: (14) Ha is Henry’s constant (Pa ·m3·mol-1) and [NH3]int is concentration of ammonia at liquid-gas interface (mol·m-3). As explained at the previous section 1.1, in aqueous solution equilibrium is established between dissolved ammonia gas and ammonium ions, where according to equation (1) the ionization constant of ammonia is. (15) Since the pH is maintained during the process, the concentration of OH- is kept constant in the lumen and is given by (16) Substituting the equation 16 in equation 15 it is observed that kb is a function of pH. At higher pH values, the kb will be smaller and the equilibrium move towards the formation of ammonium. By the other hand, a mass balance over ammonia tank under the assumption of uniform mixing can be written: )( tan, tan kLzj kCCQ dt dC V (18) Initial Condition: at t= 0 k CC tan0 (19) 4. Use of COMSOL Multiphysics One single hollow fiber is simulated using a 2D axisymmetric model. The equations were nondimensionalized only in terms of the aspect 2 1 airaporeakporeca DDD ,,,,, 111 2/1 ,, 8 3a gpore poreak M TRd D int 3 int, NHHP a a g 3 4 NH OHNH kb 14 10pH OH Ammonium removal from wastewater by liquid-liquid membrane contactors 67 ratio of the fiber, then in order to solve equation (3) using the PDE coefficient form the coordinates are Z=z/L and R=r/rhf., where L and rhf are the hollow fiber length and radius respectively. The coefficient values for the settings of the coefficient form would be: Diffusion coefficient: 2 2 0 0 L D r D chf (20) Convection coefficient LRU rD hf /12 / 2 (21) Mass coefficient 1 a d (22) In order to obtain the transport phenomena in the boundary condition equal to R=1, a flux boundary condition is set: TR p r k R C D g a g hf poreg R j j int, , 1 (23) The partial pressure of ammonia in the interface is according to equations 9-16: 14 1, int, 10 1pH b Rja a g K CH p (24) Recirculation is taken into account as a boundary condition in Z=1, where equation (18) is taken in to account as a global equation that describes the concentration in the tank: tCC kZj tan0, (25) The pH of the solution in the tank was considered as a time dependant function, fitted in a previous step in MATLAB from experimental results with the equation (26), see Figure 3. 2/34 2/3 0 010*58.6 )( t tpHpH pHtpH end (26) Figure 4. Evolution of pH in an experiment without buffer solution. 5. Results: In the Figure 5 is shown how the concentration is decreasing when the fluid pass the lumen of a fiber, at R=1 the transport of the ammonia trough the membrane to the acid solution is occurring. Different simulations have been done. From the Figure 6 is evident that this model is independent of the initial concentration set in the tank with ammonium chloride. According to Figure 7 and Figure 8, the improvement in the efficiency of this separation process by rising the pH or the flow rate is limited by some extend and this information can be used to optimize resources and energy needed to carry out the operation. This information is in agreement with the results obtained in 68 Ammonium removal from wastewater by liquid-liquid membrane contactors previous works done before without the use of COMSOL1,2 Figure 5. Distribution of Cj over plane inside the fiber for a t=10000 seconds. Figure 6. Normalized concentration evolution in the feeding tank at different initial concentrations from 0.5 ppm of ammonium to 3with a Q=4.392e-6 m3/s and pH=10.3. Figure 7. Normalized concentration evolution in the feeding tank at different pH at Q= 4.392e-6 m3/s and Co=15 ppm. Figure 8. Normalized concentration evolution in the feeding tank at different flow rates (Q in m3/s) Co=15ppm and pH=10.3. Some experiments were done to test the performance of the model. In Figure 6 is shown the evolution of the tank concentration under different experimental conditions in terms of flow rate and initial pH, as well as the predicted values. In the experiment 2 a poor removal of NH+4 was obtained because no buffer solution was added and pH was not constant. Next experiments were made with initial buffered solution. The experiment 1 and 4 were performed under same conditions but the solutions were prepared on tap water and distillate water, respectively Some deviation were observed in tap water experiment, but nevertheless, a good agreement were observed between experimental and simulated values. Ammonium removal from wastewater by liquid-liquid membrane contactors 69 Figure 9. Comparison of the evolution in different experiments of the concentration in the feeding tank with its respective simulation. 6. Conclusions The use a liquid-liquid membrane contactor to improve the water quality used in the production of hydrogen is a good option. When the process is carry out in closed loop there are no emotions to the atmosphere and this contributes to make the process safe and environmentally friendly. This model can be used to evaluate the hollow fiber membrane contactors performance for ammonia removal from aqueous solutions under different processing conditions and to define the operational parameters necessary to remove ammonia efficiently. The membrane contactor model proposed is suitable for prediction of ammonium removal in view the minimal deviations when compared to the experimental data. The most important parameters to control during the experiment are the flow rate and the pH, mainly the last one, due to the high dependence in the chemical equilibrium of ammonium reaction to ammonia. Finally, the use of COMSOL makes easier and faster to solve the equations proposed in the model for liquid-liquid contactor. More rigorous approaches will be taken in to account in further works where the model include the solution for the hydrodynamics inside the membrane contactor and open loop regime will be evaluated. 7. References 1. Mandowara and Bhattacharya, Simulation studies of ammonia removal from water in a membrane contactor under liquid-liquid extraction mode, Journal of Environmental Management, 92, 121-130 (2011) 2. Mandowara and Bhattacharya, Membrane contactor as degasser operated under vacuum for ammonia removal from water: A numerical simulation of mass transfer under laminar flow conditions, Computers and Chemical Engineering, 33, 1123–1131 (2009) 3. Agrahari et al., Model prediction and experimental studies on the removal of dissolved NH3 from water applying hollow fiber membrane contactor, Journal of Membrane Science, 390–391, 164–174 (2012) 4. Hasanoglu et al., Ammonia removal from wastewater streams through membrane contactors: Experimental and theoretical analysis of operation parameters and configuration, Chemical Engineering Journal, 160, 530–537 (2010) 8. Acknowledgements This study has been supported by the ZERODISCHARGE project (CPQ2011-26799) financed by Ministry of Science and Innovation 70 Ammonium removal from wastewater by liquid-liquid membrane contactors and the Catalan government (project ref. 2009SGR905). 9. Appendix Table 1: Properties of the membrane contactor. Membrane Contactor Property Typical Values Units Porosity 40 % Pore Dimensions 0.04 x 0.10 µm µm Effective Pore Size 0.04 µm Burst Strength 220 PSI (15.5 kg/cm2) Tensile Break Strength 175 gr/filament Resistance to Air Flow 25-45 Gurley sec. Shrinkage, Axial Direction 5 % Internal Diameter 240 µm Wall Thickness 30 µm Outer Diameter 300 µm Figure 10. Outline of the Greenlysis project. Ammonium removal from wastewater by liquid-liquid membrane contactors 71 13. References Agrahari G., Shukla S., Verma N., Bhattacharya P., 2012. Model prediction and experimental studies on the removal of dissolved NH3 from water applying hollow fiber membrane contactor. Journal of Membrane Science 390–391, 164–174. Albrecht W., Hilke R., Kneifel K., Weigel Th., Peinemann K.V., 2005. Selection of microporous hydrophobic membranas for use in gas/liquid contactors: an experimental approach. Journal of Membrane Science 263, 66-76 Al-Marzouqi M., El-Naas M., Marzouk S., Abdullatif N., 2008. Modeling of chemical absorption of CO2 in membrane contactors. Separation and Purification Technology 62, 499–506 Ashrafizadeh S.N., Khorasani Z., 2010. Ammonia removal from aqueous solutions using hollow-fiber membrane contactors Chemical Engineering Journal. 162, 242-249 Atchariyawut S., Fena C., Jiraratananon R., Liang D.T., 2006. Effect of membrana structure on mass-transfer in the membrane gas-liquid contacting process using microporous PVDF hollow fibers. Journal of Membrane Science 285, 272-281 Baker R. W., 2000. Membrane technology and applications. McGraw-Hill. 189-210 Baset D.C., 1985. Poly (vinylidene fluoride), development in crystalline polymers. Applied Science, vol. 1 Bottino A., Capannelli G., Comite A., Di Felice R., Firpo R., 2008. CO2 removal from a gas stream by membrane contactor. Separation and Purification Technology 59, 85-90