Single-MOSFET DC thermal sensor for RF-amplifier central frequency extraction

Reverter Cubarsí, Ferran,Perpiñà Gilabet, Xavier,Barajas Ojeda, Enrique,León, Javier,Vellvehi, Miquel,Jordà, Xavier,Altet Sanahujes, Josep

Abstract

© 2017 Elsevier B.V. A DC thermal sensor based on a single metal-oxide-semiconductor field-effect transistor (MOSFET) is proposed to extract high-frequency electrical features of embedded circuits. The MOSFET sensor is monolithically integrated with the circuit under test (CUT) and then monitors by thermal means the DC power dissipated by the CUT, which carries high-frequency electrical information. After explaining the theory behind this testing approach, the paper demonstrates the feasibility of the proposed MOSFET sensor through simulations and experiments. These are carried out using a radio-frequency (RF) power amplifier as a CUT and thermally extracting its central frequency (440 MHz). The MOSFET sensor results are assessed using an infrared camera as a reference. The main advantage of the proposed sensing method is that the impact on the integrated circuit (IC) layout area is minimum, which is crucial when testing RF-ICs. Moreover, in comparison with previous works, the cost and complexity of the required instrumentation is lower.

Full text

1 Single-MOSFET DC Thermal Sensor for RF-Amplifier Central Frequency Extraction Authors: Ferran Revertera, Xavier Perpiñàb, Enrique Barajasa, Javier Leónb, Miquel Vellvehib, Xavier Jordàb, Josep Alteta Affiliation: a Department of Electronic Engineering Universitat Politècnica de Catalunya (UPC) - BarcelonaTech 08034 Barcelona, Spain b Institut de Microelectrònica de Barcelona, IMB-CNM (CSIC) Campus UAB, Carrer dels Til·lers, 08193 Cerdanyola, Spain Corresponding author: Ferran Reverter, [email protected] Phone: +34 934137076 Telefax: +34 934137007 2 Abstract— A DC thermal sensor based on a single metal-oxide-semiconductor field-effect transistor (MOSFET) is proposed to extract high-frequency electrical features of embedded circuits. The MOSFET sensor is monolithically integrated with the circuit under test (CUT) and then monitors by thermal means the DC power dissipated by the CUT, which carries high-frequency electrical information. After explaining the theory behind this testing approach, the paper demonstrates the feasibility of the proposed MOSFET sensor through simulations and experiments. These are carried out using a radio-frequency (RF) power amplifier as a CUT and thermally extracting its central frequency (440 MHz). The MOSFET sensor results are assessed using an infrared camera as a reference. The main advantage of the proposed sensing method is that the impact on the integrated circuit (IC) layout area is minimum, which is crucial when testing RF-ICs. Moreover, in comparison with previous works, the cost and complexity of the required instrumentation is lower. Keywords: IC testing; MOSFET; RF testing; temperature sensor; thermal coupling; thermal testing. 3 1. INTRODUCTION On-chip thermal sensors are nowadays widely employed [1], and not only in industrial and environmental temperature monitoring applications, but also to compensate for the thermal dependence of other sensors (e.g. piezoresistive sensors), to indirectly measure other parameters (e.g. infrared radiation and humidity), and to monitor the chip thermal profile, which is the application of interest here. Extensive research has been carried out in the development of low-power, small-area on-chip thermal sensors for the thermal management of digital integrated circuits (IC) [2-6]. The aim of these designs is the early detection of hotspots so as to ensure the reliability and the performance of other embedded circuits. On-chip thermal sensors have also been proposed to test/characterize analog radio-frequency (RF) ICs. The thermal sensor is placed near the RF circuit under test (CUT) and then it measures onchip thermal variations caused by the power dissipated by the CUT, with the purpose of extracting electrical information. Figures of merit (FOM) such as the central frequency [7-8], the 1-dB compression point (CP) [9], and the DC power drawn [10] have been thermally extracted. The test/characterization of RF-ICs through on-chip thermal sensors has three main advantages. First, none of the nodes of the RF-CUT is electrically loaded by the thermal sensor and, hence, there is no performance degradation of the RF-CUT. Consequently, a simultaneous co-design of the CUT and the sensor is not required, as it happens in conventional testing strategies based on electrical sensors [11,12]. Second, thanks to the frequency down conversion generated by Joule effect, the sensor output signal shows either a DC level change in a single-tone (homodyne) excitation [8] or a low-frequency (e.g. 1 kHz) sinusoidal signal in a two-tone (heterodyne) excitation [7], regardless of the operating frequency of the RF-CUT. Therefore, the testing setup does not need expensive RF instrumentation at the output. And third, the measurement method not only facilitates a 4 pass/fail screening in a low-cost high-volume manufacturing test environment, but also enables the on-line monitoring of features during normal operation of the RF-IC. In that sense, on-line self-healing techniques based on thermal sensors have been proposed. For example, in [13], the output signal of the thermal sensor was employed to adjust a tunable load-matching network. As for the on-chip thermal sensor, the simplest sensing device that can be employed is a diode [10] or a diode-connected transistor, with either a bipolar junction transistor (BJT) [14,15] or a metal-oxide-semiconductor field-effect transistor (MOSFET) [16,17]. BJT-based thermal sensors, which can be fabricated in CMOS technology using parasitic (lateral or substrate) BJTs, have a higher accuracy, but this is not a key element here since the magnitude of interest is the change of temperature caused by the CUT and not its absolute value. MOSFET-based thermal sensors, however, are fully compatible with CMOS technology, have a higher thermal sensitivity especially in strong inversion, and require a smaller layout area [16,17]. This last point is crucial because a small sensing device can be easily fit in empty areas around the CUT with minimum impact on the IC design. Moreover, if the area overhead is minimum, then different thermal sensors can be employed to individually test/characterize each of the blocks of a RF system-on-chip. Thermal measurements can also be carried out using off-chip optical instrumentation, such as an infrared-radiation (IR) camera [18,19], but this is less attractive in terms of cost, integration and on-line monitoring. This paper aims to prove that a thermal sensor based on a single diode-connected MOSFET measuring DC thermal changes can be employed to extract electrical high-frequency FOM, such as the central frequency of a RF power amplifier (PA). The MOSFET sensor is the same proposed in [9], but the measurement method proposed herein is simpler and requires lower cost off-chip instrumentation. Whereas in [9] the MOSFET sensor measured AC thermal signals resulting from the heterodyne excitation, here it measures DC thermal changes 5 resulting from the homodyne excitation. Whereas in [9] the sensor output signal was measured by a lock-in amplifier synchronized with the RF signal generator, here it is measured by a low-cost digital multimeter. The extraction of the central frequency of a RF circuit by measuring DC thermal changes has been proposed elsewhere [8, 20], but using more complex sensor topologies not devoid of limitations. These were based on a differential configuration of two BJT sensing devices set to be the differential pair of the input stage of an operational transconductance amplifier. Its main limitations were: (i) a large area around the CUT was required since the sensing device was a parasitic BJT [17], and (ii) a preliminary calibration was needed so as to adjust the mismatch between the two BJT sensing devices and, hence, avoid the saturation of the amplifier output. These limitations are here solved by using a single MOSFET as a thermal sensor, involving a smaller area, no mismatch problems, and fully compatibility with CMOS technology. The paper is organized as follows. Section 2 describes the case under study. Section 3 provides electrical and thermal simulation results. Section 4 shows the chip designed and its experimental characterization in both electrical and thermal domains. Finally, Section 5 draws the main conclusions. 2. TESTING APPROACH 2.1. Thermal sensor With the aim of reducing as much as possible the area required and, hence, the impact on the RF-IC layout, we propose to carry out the on-chip thermal measurements through a single MOSFET, which is diode-connected and biased with a DC current source (IB), as shown in Fig 1(a). Assuming operation in strong inversion, this MOSFET provides an output voltage (vout) that linearly depends on temperature with the following sensitivity [16] B T 00 ox 2 1 2 I S W TC L      , (1) 6 where  is the temperature coefficient of the threshold voltage,  is the exponent of the temperature dependence of the mobility, T0 is a reference temperature, µ0 is the carriers mobility at T0, Cox is the gate oxide capacitance per unit area, and W and L are the width and length of the MOSFET channel, respectively. According to (1) and taking into account that  < 0, a high (positive) value of ST can be obtained using a high value of IB and/or a low value of W/L. The following three remarks should also be considered for the MOSFET thermal sensor shown in Fig. 1(a). First, although the DC operating point can be quite susceptible to process variations, this is not a major concern here since the information will be in the change of the DC level. Second, IB is assumed to be unaffected by the power dissipated by the CUT, because either its placement inside the chip will be far enough from the dissipating device or it will be provided by an external bench-top DC current source. And third, the output voltage can also change due to variations of the ambient temperature, but these changes are expected to be much slower than those generated by the test itself and, therefore, the thermal effects of the RF-CUT should be clearly distinguishable. 2.2. RF-CUT The RF-CUT selected to be tested in the thermal domain is the class-A RF-PA shown in Fig. 1(a), which has a band-pass filter response with a central frequency (fc) located in the ultra-high frequency (UHF) band and a power gain GP. The RF input signal (RFin) is connected through a matching network (L1 in series with C1) to a MOSFET (M1) in a common-source topology with resistive feedback (through R1) and inductive source degeneration (through L3). This stage is then connected to an inductive load (L2) through a cascode transistor (M2), whose bias point is determined by a control voltage (VCTL). At the central frequency, the RF output signal (RFout), which is AC-coupled through Cout, has a power that is GP times higher than that of RFin. The value of the components and the dimensions of the transistors are summarized in Table I. 7 2.3. Thermal coupling The CUT and the sensor, located at the top of the die, are thermally coupled through the semiconductor substrate. If the power dissipated by the CUT is in DC, thermal effects are inversely proportional to the distance and, hence, it is advisable to place the thermal sensor as close as possible to the power dissipating device. However, a very short distance can cause a significant CUT-sensor capacitive electrical coupling. On the other hand, if the power dissipated is in AC, the thermal coupling shows a low-pass filter (LPF) response so that the thermal effects of high-frequency power components are filtered out. The cut-off frequency of such a LPF response depends, among others, on the CUT-sensor distance, but values lower than 10 kHz are expected [9]. In the case under study, we propose to place the MOSFET thermal sensor close (say, a few microns) to the cascode transistor [M2 in Fig. 1(a)] of the RF-PA so as to monitor its power dissipated in DC. The current source (IB), in case it is embedded into the same chip, should be placed far enough from M2 (say, tens or hundreds of microns) in order to be unaffected by the dissipated power. 2.4. Homodyne excitation The thermal characterization of the RF-PA shown in Fig. 1(a) is proposed to be carried out by applying a single RF tone, with a frequency f, to the input, which is known as homodyne excitation [8]. As a consequence of this excitation, the voltages and currents at the main mesh of the circuit have a DC component together with an AC component at f; this is assuming that the relation between the RF voltage applied at the gate of M1 and the resulting drain-source current is linear. Consequently, the voltage drop and the current through M2 can be expressed, respectively, as 2 DC AC ( ) sin(2 π ) v t V V ft   (2a) 2 DC AC ( ) sin(2 π ) i t I I ft     (2b) 8 where VDC (or IDC) is the DC voltage (or current) level related to the DC operating point of M2, VAC (or IAC) is the amplitude of the voltage (or current) component at f, and  is the phase shift between the voltage and current components at f. Using (2), the power dissipated by M2 can be calculated as AC AC 2 2 2 DC DC Term 1 Term 2 AC DC DC AC AC AC ( ) ( ) ( ) cos 2 sin(2 π ) sin(2π ) cos(4π ) 2 V I p t v t i t V I V I ft V I ft V I ft               (3) which has spectral components at DC, f and 2f. The components at f and 2f [i.e. the last three terms in (3)] are expected to be filtered out by the LPF response of the thermal coupling and, therefore, the sensor will not detect thermal oscillations at these frequencies; note that the cutoff frequency of such a LPF is ten thousand times smaller than the minimum value of f under test (i.e. 100 MHz). On the other hand, the power dissipated at DC does generate DC thermal effects in the neighbourhood of M2. This DC power has two subcomponents: (i) Term 1 that depends on the DC operating point (VDC and IDC), which is expected to be quite independent of f, and (ii) Term 2 that depends on the AC voltage and current amplitudes. The central frequency of the RF-PA is proposed to be thermally extracted by exploiting the idea that part of the DC power dissipated by M2 depends on the amplitude of the highfrequency signal [i.e. Term 2 in (3)]. Note that the values of VAC, IAC and  depend on f and, therefore, the DC temperature (Ts) at the sensor position also depends on f, as qualitatively shown in Fig. 1(b). At the central frequency, where the AC signal is maximally transferred to the output, a minimum value of Term 2 is expected, thus minimizing both the DC dissipated power and Ts. This is proved in the following sections through simulations and experiments. 3. SIMULATIONS 3.1. Electrical simulations 9 The RF-PA shown in Fig. 1(a) has been electrically simulated in Cadence using VDD = 3.3 V and VCTL = 3.2 V, which are the same values used later in Section 4. A high value of VCTL was employed because it provides a higher value of GP, but at the expense of a higher current consumption. A high value of VCTL also involves a higher DC power dissipation through both subcomponents [i.e. terms 1 and 2 in (3)], which is beneficial to prove the proposed sensor. The simulated frequency response of the RF-PA is represented in Fig. 2, for an input power of 10 dBm. The amplifier shows fc = 550 MHz and GP = 14.7 dB. Additional simulations were conducted at 550 MHz to determine the 1-dB CP, i.e. the input power that provides an output power that is 1 dBm smaller than that expected in an ideal linear amplifier [21]. Such simulation results are shown in Fig. 3, where we can observe that the relation between the output power and the input power is linear (i.e. slope of one on a log-log scale) at low levels of input power, but it becomes nonlinear at high levels. The 1-dB CP is at 4.5 dBm providing an output power of 9 dBm. After characterizing the central frequency and the 1-dB CP, we studied through simulations the DC power dissipated by M2 versus frequency. These simulations were carried out using the Harmonic Balance (HB) method that calculates the magnitude and phase of voltages and currents in steady state at many harmonically-related frequencies, requiring less time and memory than a conventional transient analysis. Fig. 4 shows, for instance, the simulation results for an input power of 10 dBm, where we can observe that the DC power dissipated by M2 has a minimum at the central frequency (i.e. 550 MHz), as already suggested in Section 2.4. This confirms that the monitoring of the central frequency through thermal measurements is feasible. If the test is done at an input power higher than 10 dBm, the results are very similar to those represented in Fig. 4 but with a higher power change (ΔP). For instance, at 5 dBm input power, which is the limit of the linear region according to Fig. 3, the DC power dissipated by M2 changes from 100 mW (at 100 MHz) to 90 mW (at 550 MHz). 16 healing for mm-wave power amplifiers, IEEE Trans. Microw. Theory Tech. 61 (3) (2013) 1301-1315. [11] Q. Yin, W. R. Eisenstadt, R.M. Fox, T. Zhang, A translinear RMS detector for embedded test of RF ICs, IEEE Trans. Instrum. Meas. 54 (5) (2005) 1708-1714. [12] A. Valdes-Garcia, R. Venkatasubramanian, J. Silva-Martinez, E. Sánchez-Sinencio, A broadband CMOS amplitude detector for on-chip RF measurements, IEEE Trans. Instrum. Meas. 57 (7) (2008) 1470–1477. [13] Z. Zheng, L. Sun, J. Liu, A 60-GHz power amplifier design with on-chip tunable loadmatching network and power detect in 90-nm CMOS, IEEJ Trans. Elect. Electron. Eng. 12 (1) (2017) 140-146. [14] M.A.P. Pertijs, A.L. Aita, K.A.A. Makinwa, J.H. Huijsing, Low-cost calibration techniques for smart temperature sensors, IEEE Sensors J. 10 (6) (2010) 1098-1105. [15] A.L. Aita, M.A.P. Pertijs, K.A.A. Makinwa, J.H. Huijsing, G.C.M. Meijer, Lowpower CMOS smart temperature sensor with a batch-calibrated inaccuracy of ±0.25ºC (±3) from -70ºC to 130ºC, IEEE Sensors J. 13 (5) (2013) 1840-1848. [16] F. Reverter, J. Altet, MOSFET temperature sensors for on-chip thermal testing, Sens. Actuators A 203 (2013) 234-240. [17] F. Reverter, J. Altet, On-chip thermal testing using MOSFETs in weak inversion, IEEE Trans. Instrum. Meas. 64 (2) (2015) 524–532 [18] J. León, X. Perpiñà, J. Sacristán, M. Vellvehi, A. Baldi, X. Jordà, Functional and consumption analysis of integrated circuits supplied by inductive power transfer by powering modulation and lock-in infrared imaging, IEEE Trans. Ind. Electron. 62 (12) (2015) 7774–7785. [19] X. Perpiñà, J. León, J. Altet, M. Vellvehi, F. Reverter, E. Barajas, X. Jordà, Thermal phase lag heterodyne infrared imaging for current tracking in radio frequency integrated circuits, Appl. Phys. Lett. 110 (2017) 094101. 17 [20] E. Aldrete-Vidrio, D. Mateo, J. Altet, M. Amine Salhi, S. Grauby, S. Dilhaire, M. Onabajo, J. Silva-Martinez, Strategies for built-in characterization testing and performance monitoring of analog RF circuits with temperature measurements, Meas. Sci. Technol. 21 (2010) 075104 (10pp). [21] B. Razavi, RF Microelectronics, 2nd ed., Pearson, Upper Saddle River (NJ), 2012. [22] X. Jordà, X. Perpiñà, M. Vellvehi, F. Madrid, D. Flores, S. Hidalgo, J. Millán, Lowcost and versatile thermal test chip for power assemblies assessment and thermometric calibration purposes, Appl. Therm. Eng. 31 (2011) 1664-1672. [23] M. Vellvehi, X. Perpiñà, G. L. Lauro, F. Perillo, X. Jordà, Irradiance-based emissivity correction in infrared thermography for electronic applications, Rev. Sci. Instrum. 82 (11) (2011) 114901. 18 List of Figure Captions Figure 1. (a) Schematic circuit of the RF-PA and the MOSFET thermal sensor. (b) Waveforms of interest from the circuit in Fig. 1(a). Figure 2. Simulation results of the frequency response of the RF-PA shown in Fig. 1(a), for an input power of 10 dBm. Figure 3. Simulation results of the linearity test of the RF-PA shown in Fig. 1(a), at a frequency of 550 MHz. Figure 4. Simulation results of the DC power dissipated by M2 [i.e. the cascode transistor in Fig. 1(a)] versus frequency, for an input power of 10 dBm. Figure 5. Simulated plan views of the isothermal lines in steady state, for two values of the DC dissipated power: 100 mW and 90 mW. Figure 6. Microphotograph of the chip layout including the RF-PA under test and the MOSFET thermal sensor. Figure 7. Block diagram of the experimental setup employed to electrically and thermally test the RF-PA. Figure 8. Experimental results of the frequency response of the RF-PA shown in Fig. 1(a), for an input power of 10 dBm. Figure 9. Experimental results of the linearity test of the RF-PA shown in Fig. 1(a), at a frequency of 440 MHz. Figure 10. Experimental results of the DC thermal change (measured by the MOSFET sensor and the IR camera) versus frequency, for an input power of 3 dBm; ΔT was calculated using as a reference the temperature obtained at 100 MHz. Figure 11. Thermal map monitored by the IR-camera at 440 MHz represented as a difference with respect to that obtained at 100 MHz. 19 List of Table Captions Table I. Value and dimensions of the components employed in the RF-PA shown in Fig. 1(a). (a) It is composed of an on-chip inductance (5 nH) plus the bond-wire inductance. (b) Parasitic inductance mainly generated by the bond wire and the PCB track. (c) Parasitic inductance generated by the bond wire; it is smaller than L2 since the CUT has several pads (VSS in Fig. 6) connected to ground. 20 Figure 1 VDD RFout RFin VCTL W/L MOSFET thermal sensor VSS L1C1 M1 M2 Cout R1 R2 C2 L2 L3 IB Thermal coupling vout Ts (a) Vout t RFin t t vout t1 T Ts (b) i2v2 + - t2 21 Figure 2 -20 -10 0 10 20 100 1000 Power gain (dB) Frequency (MHz) 550 MHz 14.7 dB 22 Figure 3 -10 -5 0 5 10 15 -20 -15 -10 -5 0 5 Output power (dBm) Input power (dBm) 1dBm 9 dBm -4.5 dBm 23 Figure 4 93.5 94.0 94.5 95.0 95.5 96.0 96.5 97.0 100 1000 DC power dissipated by M 2 (mW) Frequency (MHz) DP=2.4 mW 550 MHz 24 Figure 5 19 µm 90 mW 26 24ºC 25ºC 26ºC 27ºC 28ºC 29ºC23ºC 100 mW 27 25 Figure 6 RFin L1 C1 M1 Thermal sensor C2 VSS VSS VSS VCTL VDD VSS VSS RFout Cout