scieee AI-readable full text Open interactive document viewer

Micro-mechanical homogenisation of three-leaf masonry walls under compression

Drougkas, Anastasios,Sarhosis, Vasilis

Abstract

Three-leaf masonry panels are typically composed of external leaves of irregularly bonded units and a rouble infill. The complexity of the response of these structures to mechanical loading arises from: a) the interaction of the leaves and b) the irregularity of the bond pattern of the outer leaves. This complexity makes analytical and computational modelling of these structures difficult and costly, respectively. This paper proposes a computational approach for the calculation of the mechanical properties of the three- leaf masonry from the properties of its constituent materials and its geometry. Using micro-mechanical anal- ysis approaches applied in composite materials and accounting for the interaction of the leaves through a simple analytical approach, the homogenised elastic stiffness and strength of a representative volume element of three- leaf masonry can be calculated with very low computational cost. The analysis method is validated against experimental results from the literature. It is found that the proposed model provides accurate results for a relatively wide range of case studies. These results are expanded upon through a sensitivity study, highlighting the most important material and geometric parameters influencing the predicted compressive strength of three-leaf masonry walls

Full text

1 Micro-mechanical homogenisation of three-leaf masonry walls 1 under compression 2 Anastasios Drougkas 1 , Vasilis Sarhosis 3 School of Civil Engineering, University of Leeds, Woodhouse Lane, LS2 9JT, Leeds, United Kingdom 4 Abstract 5 Three-leaf masonry panels are typically composed of external leaves of irregularly bonded units and a 6 rouble infill. The complexity of the response of these structures to mechanical loading arises from: a) the 7 interaction of the leaves and b) the irregularity of the bond pattern of the outer leaves. This complexity 8 makes analytical and computational modelling of these structures difficult and costly, respectively. 9 This paper proposes a computational approach for the calculation of the mechanical properties of the 10 three-leaf masonry from the properties of its constituent materials and its geometry. Using micro- 11 mechanical analysis approaches applied in composite materials and accounting for the interaction of the 12 leaves through a simple analytical approach, the homogenised elastic stiffness and strength of a 13 representative volume element of three-leaf masonry can be calculated with very low computational cost. 14 The analysis method is validated against experimental results from the literature. It is found that the 15 proposed model provides accurate results for a relatively wide range of case studies. These results are 16 expanded upon through a sensitivity study, highlighting the most important material and geometric 17 parameters influencing the predicted compressive strength of three-leaf masonry walls. 18 Keywords 19 masonry – micro-mechanics – damage mechanics – homogenisation – multi-scale modelling 20 1 Corresponding author: A.Drougka[email protected]c.uk 2 1 Introduction 21 Three-leaf masonry construction is a very common structural typology, strongly linked with both 22 architectural heritage and vernacular construction. It is typically composed of two external leaves made of 23 regularly or, more frequently, irregularly bonded stone or brick masonry and an inner leaf made of low 24 cohesion, low strength materials, including loose mortar, soil and stone or brick fragments. Three-leaf 25 masonry is a highly heterogeneous structure, composed of macroscopically distinguishable material 26 phases and leaves with widely different mechanical properties [1]. Failure in these structures under 27 mechanical loading may occur due to separation of poorly interlocked leaves, out-of-plane collapse or 28 failure of the materials in tension, shear or compression. Load transfer between the material phases and 29 between the distinct leaves, which governs the developed stresses within each constituent material, 30 depends on numerous mechanical and geometric properties characterising the three-leaf structure and the 31 connectivity of the leaves [2]. 32 Experimental campaigns characterising the mechanical properties of three-leaf masonry, accompanied 33 by comprehensive characterisation of the individual materials, are relatively few [2–6]. Despite the limited 34 number of such studies, the results are enlightening in terms of describing the failure mode and the salient 35 characteristics of the response. These studies typically include the determination of the Young’s modulus 36 and compressive strength, the measurement of the effects of grouting or other strengthening measures on 37 capacity and the investigation of the interaction between leaves [1]. 38 A variety of models for three-leaf masonry has been proposed in the literature. Analytical expressions 39 for predicting the compressive strength [6–9] have been calibrated, relying partly on the mechanical 40 properties of the materials and partly on empirical or semi-empirical observations or qualitative 41 assessments of leaf interlocking. Further, computational modelling using finite elements has been 42 attempted [2,10], this approach being very case-specific and characterised by high computational cost and 43 modelling effort. Finally, method-of-cells approaches have been successfully applied for the analysis of both 44 single-leaf [11] and multi-leaf masonry structures [12]. 45 3 A very promising approach for the analysis of the external leaves of three-leaf masonry is treating the 46 outer leaf as a composite material consisting of a mortar matrix with stone or brick unit inclusions. This 47 approach is suitable for providing averaged values of stresses in the components of a composite material 48 and for calculating the homogenised properties of the material with low computational cost. In the initially 49 studied case of a composite material consisting of particle inclusions in a matrix, it is possible to relate the 50 stresses within the inclusion to a given applied stress in an infinite matrix [13]. This model was later 51 extended to account for composite materials with tightly packed inclusions and the interaction between 52 them and with the surrounding matrix [14,15], a condition more closely resembling that encountered in 53 the external leaves of masonry structures. While the shape of the inclusions is often considered to be 54 ellipsoidal, and despite solutions of the problem existing for near-rectangular inclusions [16], this 55 modelling approach has been applied in linear elastic modelling masonry structures with ellipsoidal 56 inclusions approximating cuboid brick units with good accuracy [17]. Finally, nonlinear analyses of 57 cements and mortar using this micro-mechanical approach have been successful in capturing the behaviour 58 of brittle materials [18–21], providing a basis for application on masonry structures. 59 In this paper a model for the calculation of the elastic properties of three-leaf masonry structures is 60 proposed. This goal is accomplished through a combined use of micro-mechanical modelling and analytical 61 expressions for the homogenisation of the external leaf and the simulation of leaf interaction, respectively. 62 This approach allows for the calculation of mechanical properties, primarily of the compressive strength, 63 as a function of the geometric disposition and mechanical properties of the primary components 64 comprising the three-leaf structure: units, mortar and fill material. Simultaneously, the coupled use of 65 micro-mechanics and analytical expressions keeps the computational cost of non-linear analysis low. 66 The accuracy of the model is validated against experimental data involving compression tests on three- 67 leaf masonry members. Only case studies with sufficient material characterisation are considered in this 68 validation in order to minimise the number of assumptions concerning unknown material properties. 69 Finally, a sensitivity study is performed for identifying the geometric and material parameters that have 70 the strongest effect on the compressive strength of the masonry. This investigation can serve as a guide for 71 4 future characterisation efforts in the study of three-leaf masonry structures through the identification of 72 the most crucial material parameters. 73 2 Two-scale micro-mechanical model 74 2.1 Overview 75 The proposed model deals with the simulation of three-leaf masonry structures under mechanical 76 loading. At the macro-scale, the structure consists of two outer leaves and an enclosed inner leaf. The outer 77 leaves are composed of masonry units and mortar joints, while the inner leaf is composed of stone or brick 78 fragments embedded in a highly porous fill material; the latter often being the same material as the mortar 79 in the joints but less compacted. In the present study, it is considered that the inner and outer leaves are 80 connected through a plane interface, thus not explicitly considering the potential presence of keyed collar 81 joints. A visual representation of a representative three-leaf masonry structure is given in Figure 1. 82 83 Figure 1 General layout of three-leaf masonry structure featuring units of different sizes. 84 The modelling strategy consists in the serial two-scale analysis of three-leaf masonry walls. At the 85 micro-scale, the interaction of the components within the leaves is modelled for deriving the stresses and 86 strains at each material phase. At the macro-scale the interaction of the outer and inner leaves is modelled. 87 The two scales are solved separately and coupled for deriving the homogenised stresses and strains of the 88 masonry [22]. 89 5 2.2 Homogenisation of masonry leaves 90 The outer leaves of a three-leaf masonry are treated as a composite material consisting of stone or brick 91 unit inclusions in a mortar matrix. In this context, an inclusion is defined as a region embedded in an 92 infinite, homogeneous and isotropic matrix. When the matrix undergoes a change in size and shape, the 93 inclusion in turn undergoes a deformation which is different from that of the matrix, assuming the two 94 phases possess different material properties. Defining the eigenstrain 𝜺∗ as the strain state within the 95 inclusion upon removal of the constraint provided to it by the matrix, the strain within the inclusion is 96 equal to: 97 ε𝑖𝑗=𝑆𝑖𝑗𝑘𝑙𝜀∗𝑘𝑙 (1) where 𝑆𝑖𝑗𝑘𝑙 are the components of Eshelby’s tensor 𝑺. These components are a function of the shape of the 98 inclusion, with ellipsoidal inclusions having received the most attention in the literature. The outer surface 99 of an ellipsoid is defined by the equation: 100 𝑥2 𝑎12+𝑦2 𝑎22+𝑧2 𝑎32=1 (2) where 𝑎1, 𝑎2 and 𝑎3 are the half-length, half-height and half-width of the ellipsoid. These ellipsoids are 101 used for approximating the shape of units in the outer leaves, be they of cuboid or more rounded shape. 102 This approximation of cuboids with ellipsoids does not appear to lead to any marked difference between 103 computed elastic properties of the masonry and experimentally derived values [17,23]. An ellipsoidal 104 inclusion is illustrated in Figure 2. 105 6 106 Figure 2 Illustration of an ellipsoidal inclusion. 107 For ellipsoidal inclusions, with their axes as shown in Figure 2 aligned with the axes of the masonry as 108 shown in Figure 1, the components of Eshelby’s tensor 𝑺 are calculated as [24]: 109 𝑆1111=3 8𝜋(1−𝜈)𝑎12𝐼11+1−2𝜈 8𝜋(1−𝜈)𝐼1 𝑆1122=1 8𝜋(1−𝜈)𝑎22𝐼12+1−2𝜈 8𝜋(1−𝜈)𝐼1 𝑆1133=1 8𝜋(1−𝜈)𝑎32𝐼13+1−2𝜈 8𝜋(1−𝜈)𝐼1 𝑆1212=𝑎12+𝑎22 16𝜋(1−𝜈)𝐼12+1−2𝜈 16𝜋(1−𝜈)(𝐼1+𝐼2) (3) following the symmetries: 110 𝑆𝑖𝑗𝑘𝑙=𝑆𝑗𝑖𝑘𝑙=𝑆𝑖𝑗𝑙𝑘 (4) and 𝜈 being the Poisson’s ratio of the matrix. The parameters 𝐼𝑖 and 𝐼𝑖𝑗 are calculated by the elliptical 111 integrals [25]: 112 𝐼1=2𝜋𝑎1𝑎2𝑎3∫𝑑𝑠 (𝑎12+𝑠)𝛥(𝑠) ∞ 0 (5) 7 𝐼11=2𝜋𝑎1𝑎2𝑎3∫𝑑𝑠 (𝑎12+𝑠)2𝛥(𝑠) ∞ 0 𝐼12=2𝜋𝑎1𝑎2𝑎3∫𝑑𝑠 (𝑎12+𝑠)(𝑎22+𝑠)𝛥(𝑠) ∞ 0 where: 113 𝛥(𝑠)=√(𝑎12+𝑠)(𝑎22+𝑠)(𝑎32+𝑠) (6) The remaining parameters 𝐼𝑖 and 𝐼𝑖𝑗 are calculated by cyclic permutation through subscripts 1,2,3. 114 Instead of a single inclusion, we can consider a composite material 𝐶 comprised of 𝑛 inclusion groups 𝑖 115 within a matrix 𝑚. Each group represents inclusions with the same dimensions and material properties. 116 The dilute estimate 𝑻𝑖 of the 𝑖-th inclusion group is equal to: 117 𝑻𝑖=[𝑰+ 𝑺𝑖𝑪𝑚 −1(𝑪𝑖−𝑪𝑚)]−1 (7) where 𝑰 is the identity tensor and 𝑪𝑚 and 𝑪𝑖 are the stiffness tensors of the matrix and the inclusion 118 respectively. The matrix strain concentration factor 𝑨𝐶 in the composite is equal to: 119 𝑨𝐶=(𝜔𝑚𝑰+∑𝜔𝑖𝑻𝑖 𝑛 𝑖=1 )−𝟏 (8) where 𝜔𝑖 is the volume ratio of the 𝑖-th group of inclusions and 𝜔𝑚 the volume ratio of the matrix, both 120 with respect to the total volume of the composite. The strain concentration tensor 𝑨𝑖 of the 𝑖-th inclusion 121 group in the composite material is equal to: 122 𝑨𝑖=𝑻𝑖𝑨𝐶 (9) Finally, the effective stiffness tensor 𝑪𝐶 of the composite material is [26]: 123 8 𝑪𝐶=𝑪𝑚+∑𝜔𝑖(𝑪𝑖−𝑪𝑚)𝑨𝑖 𝑛 𝑖=1 (10) The strain in the matrix 𝜺𝑚 is equal to [14]: 124 𝜺𝑚=𝑨𝐶𝜺𝐶 (11) where 𝜺𝐶 is the macroscopic strain in the composite, while the stress 𝝈𝑚 in the matrix is equal to: 125 𝝈𝑚=𝑪𝑚𝜺𝑚 (12) The strain 𝜺𝑖 in the 𝑖-th group of inclusions is equal to [15]: 126 𝜺𝑖=𝑨𝑖𝜺𝑐 (13) and the stress 𝝈𝑖 is equal to: 127 𝝈𝑖=𝑪𝑖𝑨𝑖(𝑪𝑐)−1𝝈𝐶 (14) where 𝝈𝐶 is the macroscopic stress in the composite. 128 Different unit inclusion groups in masonry are often clearly defined by the orientation of the units 129 within the leaf. It is thus possible to distinguish between header, transversal or half-length header units 130 depending on the bond type. Each of these types of units constitute an inclusion group. Brick masonry is 131 often characterized by regularly sized units in the outer leaves, allowing the easy determination of the 132 dimensions 𝑎1, 𝑎2 and 𝑎3 for each inclusion group. This is not often the case in stone masonry, where the 133 sizes of the units within the same inclusion group can vary noticeably. Due to this size irregularity, the 134 dimensions 𝑎1, 𝑎2 and 𝑎3 for each unit inclusion group are calculated as the volume-weighted average for 135 each dimension in a given area in the masonry. Each average inclusion dimension 〈𝑎𝑖〉 in direction 𝑖 is equal 136 to: 137 〈𝑎𝑖〉=∑𝑎𝑖∙𝑉 ∑𝑉 (15) 9 with 𝑉 being the volume of each individual unit in the studied area of masonry. This approach ensures that 138 the average dimension is controlled by the dimension of the units occupying the greatest volume in the leaf. 139 For masonries with highly irregular texture, the calculation of the average dimensions can be performed 140 for different sections of the masonry, resulting in the calculation of different mechanical properties in each 141 section. 142 This homogenization process can be applied in a straightforward manner for the outer leaves: the 143 mortar acts as the matrix and the units as the inclusions. The geometry and volume ratio of the units can 144 be determined relatively easily through visual or photogrammetric inspection. The same process can in 145 principle be adopted for the inner leaf as well, considering the fill material as the matrix and the various 146 fragments as the inclusions. Additionally, pores can be included in the inner leaf in the form of zero-stiffness 147 inclusions. However, using this approach for the inner leaf is deemed impractical due to the typical absence 148 of accurate geometric data for the components of the inner leaf, the difficulty in acquiring such data from 149 inspection, as opposed to the case of the outer leaves, and from the fact that the inner leaf is often 150 characterised mechanically as a whole in experimental campaigns. Therefore, the inner leaf is here treated 151 for the most part as a homogeneous material. 152 2.3 Masonry leaf interaction 153 The interaction of the masonry leaves is accounted for through a method-of-cells approach for the 154 analysis of a representative volume element (RVE) of masonry [12]. In this context, the interaction is 155 modelled through simple analytical expressions of stress equilibrium and strain compatibility between the 156 inner leaves 𝐼 and outer leaves 𝑂 for calculating the elastic properties of the masonry 𝑀. Focusing on 157 normal applied stresses, and having considered a plane interface between the leaves, shear stresses and 158 strains are disregarded as these, due to the boundary conditions, do not develop in the RVE when it is 159 subjected to normal stresses/strains only. 160 Strain compatibility between the leaves dictates that both leaves deform equally in the longitudinal (𝑥) 161 and vertical (𝑦) direction leading to the strain equalities: 162 16 were made for certain material parameters based on statistical analysis of the available experimental 257 inventory [29]. The Young’s modulus 𝐸𝑢 of the units was taken as 300 times the compressive strength and 258 that of the mortar 𝐸𝑚 and fill 𝐸𝑓 as 700 times their respective compressive strength. The Poisson’s ratio of 259 the units 𝜈𝑢 was taken as 0.15 and that of the mortar 𝜈𝑚 0.25 for simulating its significant lateral expansion 260 near compressive yielding. Similarly, the Poisson’s ratio of ungrouted fill 𝜈𝑓 was taken as equal to 0.10 due 261 to its often high porosity, which decreases lateral expansion under vertical compression, while grouted fill 262 was assigned a value of 0.20 for simulating the increase in cohesion after strengthening. The tensile 263 strength of all components was taken as equal to 10% their respective compressive strength. The 264 compressive fracture energy 𝐺𝑐 is calculated for all components as [29]: 265 𝐺𝑐=𝑓𝑐𝑑 (32) were 𝑑=1 mm and the tensile fracture energy 𝐺𝑡 is calculated as [32]: 266 𝐺𝑡=73𝑓𝑐0.18 1000 (33) 4.1 Vintzileou & Tassios (1995) 267 This experimental campaign includes the compressive testing of three-leaf stone masonry wallettes 268 subjected to vertical compression before and after grouting [6]. The outer leaf is built in single-wythe 269 running bond, with alternate courses having slightly different embedment in the inner leaf, creating small 270 keyed collar joints. Therefore, two types of units are distinguished. The compressive strength of the inner 271 leaf after grouting is not reported. Therefore, only the case before grouting was used in this investigation. 272 4.2 Binda et al (2006) 273 In this case study masonry wallettes constructed of stone units, a strong mortar and a relatively 274 cohesive inner leaf were tested in compression [2]. The outer leaf is composed of alternating courses of 275 full- and half-length units. Two series of tests were conducted, each with a different geometry characterised 276 by the presence or absence of a collar joint between leaves. In this simulation only the case without collar 277 joints is simulated. 278 17 4.3 Vintzileou & Miltiadou-Fezans (2008) 279 The case study involves the compressive testing of masonry walls before and after grouting [5]. The 280 properties of the fill after grouting were not reported. For simulating the wall after grouting, the 281 compressive strength of the fill is assigned the target value reported by the authors despite this parameter 282 not having been determined directly. The two outer leaves, both in single wythe construction, feature 283 different geometric bond patterns. One leaf is composed of stone units in running bond, while the other 284 features alternating courses of header stones and half-length stones. Both leaves feature horizontally and 285 vertically arranged brick tiles, a feature typical of Byzantine architecture (cloisonné masonry) but lacking 286 extensive characterisation in the literature. All these types of units are included in the model. Further, the 287 stones feature different embedment lengths within the inner leaf. Nevertheless, the two outer leaves are 288 considered identical in the model after averaging their featured geometric properties. 289 4.4 Oliveira et al (2012) 290 This series of experiments deals with the testing in compression of stone masonry before and after 291 strengthening using grouting and other mechanical reinforcement methods [4]. The authors reported the 292 mechanical properties of the fill after grouting, allowing the simulation of the compressive testing both 293 before and after intervention. 294 4.5 Meimaroglou & Mouzakis (2018) 295 The case study involves the compressive testing of short stone masonry wallettes made using clay 296 mortar [3]. The outer leaves were constructed in a running bond pattern consisting of full-length and half- 297 length unit groups. The inner leaf was constructed using alternate layers of stone fragments and 298 uncompacted mortar but was not the subject of mechanical characterisation itself. As such, in a departure 299 from the methodology used in the other case studies simulated this paper, the properties of the fill were 300 determined by applying the homogenisation method described in this paper. 301 4.6 Summary of case studies and numerical analysis results 302 All experimental data used for numerical analysis of the case studies are presented in Table 1, which 303 includes all numerical parameters required for analysis, apart from the fracture energies which are 304 18 calculated according to Eq. (32) and Eq. (33). The properties of the fill presented for the Meimaroglou & 305 Mouzakis case were calculated numerically using the proposed model. These data are accompanied by the 306 numerical analysis results using the proposed model in terms of vertical compressive strength, Young’s 307 modulus and in-plane Poisson’s ratio. 308 19 Table 1 Experimental case study and numerical analysis results. Assumed values marked with an asterisk. Percentile difference between 309 numerical and experimentally derived values in parentheses. 310 Component Parameter Symbol [6] [2] [5] [5] [4] [4] [3] Units Unit Length 𝑙𝑢 293 293 310 150 300 180 300 180 172 172 320 160 mm Height ℎ𝑢 137 137 150 150 115 30 115 30 157 157 105 105 mm Width 𝑤𝑢 130 140 170 170 155 140 155 140 99 99 165 165 mm Compressive strength 𝑓𝑐,𝑢 100 100 17.3 17.3 25 17 25 17 52.5 52.5 107.5 107.5 Nmm2 ⁄ Tensile strength 𝑓𝑡,𝑢 10* 10* 1.8 1.8 2.5* 1.7* 2.5* 1.7* 5.25* 5.25* 3.1 3.1 Nmm2 ⁄ Young’s modulus 𝐸𝑢 30000* 30000* 8525 8525 7500* 5100* 7500* 5100* 20600 20600 32250* 32250* Nmm2 ⁄ Poisson’s ratio 𝜈𝑢 0.15* 0.15* 0.15* 0.15* 0.15* 0.15* 0.15* 0.15* 0.15* 0.15* 0.15* 0.15* − Volume ratio 𝜔𝑢 0.425 0.425 0.380 0.551 0.667 0.133 0.667 0.133 0.850 0.850 0.652 0.185 − Mortar Joint thickness 𝑡𝑚 10 10 20 20 20 20 20 mm Compressive strength 𝑓𝑐,𝑚 1.7 9.2 4.35 4.35 3.9 3.9 3.9 Nmm2 ⁄ Tensile strength 𝑓𝑡,𝑚 0.17* 0.920* 0.435* 0.435* 0.39* 0.39* 0.39* Nmm2 ⁄ Young’s modulus 𝐸𝑚 1190* 6440* 3045* 3045* 410 410 2730* Nmm2 ⁄ Poisson’s ratio 𝜈𝑚 0.25* 0.25* 0.25* 0.25* 0.25* 0.25* 0.25* − Volume ratio 𝜔𝑚 0.150 0.069 0.200 0.200 0.150 0.150 0.185 − Fill Compressive strength 𝑓𝑐,𝑓 0.15 4.0 0.15 3.00 0.29 4.1 3.58 Nmm2 ⁄ Tensile strength 𝑓𝑡,𝑓 0.015* 0.300* 0.015* 0.300* 0.029* 0.410* 0.487 Nmm2 ⁄ Young’s modulus 𝐸𝑓 105* 1616 105* 900* 41 2870* 7134 Nmm2 ⁄ Poisson’s ratio 𝜈𝑓 0.10* 0.10* 0.10* 0.20* 0.10* 0.20* 0.13 − Masonry Length 𝑙 600 310 1040 1040 600 600 700 mm Height ℎ 1200 790 1200 1200 1100 1100 550 mm Width 𝑤 400 510 450 450 300 300 500 mm Inner leaf volume ratio 𝜔𝐼 0.325 0.333 0.275 0.275 0.333 0.333 0.333 − Outer leaf volume ratio 𝜔𝑂 0.675 0.667 0.725 0.725 0.667 0.667 0.667 − Compressive strength 𝑓𝑐 1.49 5.81 1.94 3.49 2.00 3.60 4.00 Nmm2 ⁄ Young’s modulus 𝐸 4611 1770 1313 1313 2122 2008 692 Nmm2 ⁄ Numerical results Compressive strength 𝑓𝑐 1.39 (-6.5%) 6.70 (15.3%) 3.43 (+76.9%) 3.62 (+3.6%) 2.84 (+42.2%) 3.44 (-4.3%) 4.26 (6.4%) Nmm2 ⁄ Young’s modulus 𝐸 7604 (+64.9%) 6128 (+246%) 4257 (+224%) 4474 (+241%) 3982 (+87.6%) 4929 (+145%) 12203 (+1663%) Nmm2 ⁄ Poisson’s ratio 𝜈𝑥𝑦 0.257 0.146 0.175 0.168 0.263 0.235 0.212 − 311 20 Overall, the model, coupled with the assumptions presented in the description of the calculation 312 method, predicts the compressive strength of three-leaf masonry with good accuracy, despite some salient 313 characteristics of three-leaf masonry having been omitted, primarily the out-of-plane effects caused by the 314 boundary conditions. The model tends to overestimate the compressive strength, possibly due to the 315 omission of out-of-plane effects. It is not currently clear whether the empirical assumptions regarding 316 material parameters or whether elements of the modelling approach introduce a systematic bias on the 317 model. The most notable lack of accuracy is that in the Vintzileou & Miltiadou-Fezans case before grouting 318 [5], where the predicted compressive strength is 76.9% higher than the mean experimental value and 51% 319 higher than the maximum experimental value. It is notable, however, that in the grouted case in the same 320 experimental series, as in the cases investigated by Oliveira et al [4], the compressive strength is predicted 321 with much greater accuracy, indicating a mitigation of out-of-plane effects by the intervention. Since it is 322 not clear which parameter has the strongest influence on the results, and since several material parameters 323 were not directly characterised in the experimental campaign, this case will form the basis of a sensitivity 324 study. 325 The proposed model and assumptions are less successful in predicting the Young’s modulus of the 326 three-leaf masonry case studies examined here even when the Young’s moduli of the components were 327 experimentally determined. The predicted Young’s modulus is systematically higher than the 328 experimentally derived value, especially in the Meimaroglou & Mouzakis case [3], where the difference is 329 remarkable. It is noted for this case study that the value of the Young’s modulus used for the units is very 330 plausible for limestone of this strength [33], although the particulars of the limestone used are not known 331 in detail. It is possible that imperfect compaction of the mortar in the joints and the presence of 332 imperfections or voids in the inner leaf result in a reduction of the Young’s modulus of masonry. Further, 333 large differences between the empirically-derived and actual values of the Young’s moduli of the 334 components are a possible cause of this discrepancy. Consequently, the large differences between the 335 computed and experimentally measured values highlight the need for comprehensive characterisation of 336 all materials before application of the proposed model. Finally, it is currently unclear whether full 337 21 simulation of the out-of-plane interaction of the leaves could reduce the calculated Young’s modulus of 338 masonry through the induction of bending on the outer leaf. 339 5 Sensitivity study 340 The object of the study is the sensitivity of compressive strength 𝑓𝑐, Young’s modulus 𝐸 and in-plane 341 Poisson’s ratio 𝜈𝑥𝑦 of masonry to a set of material and geometric parameters. It is performed by variation 342 of a) the Young’s modulus and the Poisson’s ratio of the stone and brick units (𝐸𝑢, 𝜈𝑢) and the mortar (𝐸𝑚, 343 𝜈𝑚), namely elastic material properties that are often not characterised in experimental campaigns due to 344 practical difficulties in execution, b) the tensile 𝑓𝑡 and compressive 𝑓𝑐 strength of the fill, mortar and the 345 stone and brick units (the tensile strength in often only indirectly characterized through flexural or splitting 346 tests while the compressive strength of the fill is difficult to determine in existing structures), and c) the 347 volume ratio 𝜔𝑚 of the mortar in the outer leaf and the length 𝑙𝑢1 and height ℎ𝑢1 of the stone units, as these 348 geometric parameters may vary substantially in different locations of irregular stone masonries or cannot 349 be easily determined. Each parameter is varied without changing any of the others apart from the 350 dimensions of the stone units, which are studied jointly. The Vintzileou & Miltiadou-Fezans [5] case is used 351 for investigating elastic and geometric parameters and the Binda et al [2] case is used for investigating 352 strength parameters, since the proposed model and assumptions were less successful in accurately 353 predicting the compressive strength of the masonry in these two cases compared to the others. 354 Additionally, the former case presents the opportunity of studying the influence of the brick tiling elements 355 on the mechanical properties of cloisonné masonry. All material and geometric parameters in this section 356 that have been normalized through division with the reference values found in Table 1 are represented 357 using a hat operator, i.e. 𝑓󰆹𝑐 is equal to the compressive strength of masonry calculated after variation of a 358 parameter divided by the reference value of 𝑓𝑐. The parameters modified in the sensitivity study and the 359 range of variation are presented in Table 2. 360 22 Table 2 Sensitivity study parameters and range of variation. 361 Component Parameter Symbol Minimum Maximum Mortar Young’s modulus 𝐸𝑚 0.33 3.00 Poisson’s ratio 𝜈𝑚 0.60 1.20 Compressive strength 𝑓󰆹𝑐,𝑚 0.25 1.50 Tensile strength 𝑓󰆹𝑡,𝑚 0.25 1.50 Content ratio 𝜔𝑚 0.25 1.75 Stone units Young’s modulus 𝐸𝑢1 0.33 3.00 Poisson’s ratio 𝜈𝑢1 0.33 1.33 Compressive strength 𝑓󰆹𝑐,𝑢1 0.25 1.50 Tensile strength 𝑓󰆹𝑡,𝑢1 0.25 1.50 Length 𝑙󰆹𝑢1 0.25 2.00 Height ℎ𝑢1 0.25 2.00 Brick units Young’s modulus 𝐸𝑢2 0.33 3.00 Poisson’s ratio 𝜈𝑢2 0.33 1.33 Fill Compressive strength 𝑓󰆹𝑐,𝑓 0.25 1.50 The sensitivity of the calculated properties of masonry to elastic parameters of the components is 362 illustrated in Figure 4. The influence of the Young’s modulus 𝐸𝑚 of mortar on the compressive strength 𝑓𝑐 363 of masonry is notable. A decrease of 𝐸𝑚 can result in an increase in 𝑓𝑐 of up to nearly 20% due to higher 364 confinement of the mortar. Additionally, lowering 𝐸𝑚 increases the Poisson’s ratio 𝜈𝑥𝑦 of masonry, making 365 the composite material more prone to lateral expansion under vertical compression. Lowering the 366 Poisson’s ratio 𝜈𝑚 of the mortar results in an increase in the predicted strength of masonry due to the 367 development of lower lateral tensile stresses in the units. However, excessive reduction results in a 368 decrease in the compressive strength. An increase in this parameter has the opposite effect on the units 369 and leads to their tensile failure. It is noted that while 𝜈𝑚 can initially be very low due to porosity, it can 370 increase rapidly near compressive failure of the mortar [34], which can in turn lead to premature failure of 371 the masonry due to high tensile stresses in the units. Similarly, a higher Young’s modulus 𝐸𝑢1 of the stone 372 units leads to more confinement of the mortar and an increase in the compressive strength of masonry, the 373 overall effect being more pronounced compared to the variation of 𝐸𝑚. Increasing the Poisson’s ratio 𝜈𝑢1 374 of the units makes their lateral deformation more compatible with the lateral expansion of the mortar, 375 potentially decreasing lateral tensile stresses and reducing tensile damage. However, the effect is not 376 particularly pronounced in this case study. Despite the low volume ratio of brick units, lowering the Young’s 377 modulus 𝐸𝑢2 of brick can lead to a lower 𝑓𝑐 due to increase in the stress concentration in the mortar. Finally, 378 variation of the Poisson’s ratio 𝜈𝑢2 of the brick does not strongly influence the calculated properties of the 379 masonry. 380 23 381 Figure 4 Results of sensitivity study on elastic parameters: a) Young’s modulus of mortar, b) 382 Poisson’s ratio of mortar, c) Young’s modulus of stone units, d) Poisson’s ratio of stone units, e) 383 Young’s modulus of brick units and f) Poisson’s ratio of brick units. 384 24 The sensitivity of the calculated properties of masonry to the tensile and compressive strength of the 385 components is illustrated in Figure 5. For the investigated case, the calculated compressive strength 𝑓𝑐 of 386 masonry is insensitive to the tensile strength 𝑓𝑡,𝑚 of the mortar due to the latter component being under 387 confinement by the units. The compressive strength of masonry is not particularly sensitive to the tensile 388 strength 𝑓𝑡,𝑢1 of the stone units due to the low ratio of tensile over compressive stress developed in this 389 component in this particular case. Different combinations of elastic properties for the mortar and units can 390 lead to an increase in this ratio and result in sensitivity of the compressive strength of masonry to the 391 tensile strength of the units. Further, existing local damage to the stone units, which would induce an 392 apparent decrease in their tensile strength, could lead to a moderate reduction of the compressive strength 393 of masonry.. The compressive strength 𝑓𝑐 of the masonry is, as expected, not proportional to the 394 compressive strength of the mortar and stone units. The compressive strength 𝑓𝑐,𝑓 of the fill does not 395 strongly affect the compressive strength of the masonry due to its very low stiffness, leading to the 396 development of low compressive stresses in the fill. 397 398 Figure 5 Results of sensitivity study on inelastic parameters: a) tensile strength and b) 399 compressive strength of components. 400 The sensitivity of the calculated properties of masonry to geometric parameters is shown in Figure 6. 401 While the compressive strength 𝑓𝑐 of masonry is not particularly sensitive to the volume ratio 𝜔𝑚 of mortar, 402 the Young’s modulus 𝐸 and Poisson’s ratio 𝜈𝑥𝑦 of masonry are moderately influenced by 𝜔𝑚. A higher 403 25 mortar content increases the Poisson’s ratio and decreases the Young’s modulus of the masonry, resulting 404 in a more deformable composite material. Higher deformability in sections of masonry with thicker mortar 405 joints compared to adjacent sections can lead to deformation incompatibility, instability and loss of 406 strength. Finally, the compressive strength of masonry shows notable sensitivity to the length 𝑙𝑢1 and 407 height ℎ𝑢1 of the stone units. The interaction of the parameters presents a complex profile. Overall, 𝑓𝑐 is 408 more sensitive to changes in height for a given length for a large proportion of the variation range studied, 409 with shorter units typically yielding higher values of 𝑓𝑐. Units roughly 225 mm in length and 200 mm in 410 height, a near-square shape which is encountered in one of the external leaves of the wall, result in 411 substantially elevated values of 𝑓𝑐. 412 413 Figure 6 Results of sensitivity study on geometric parameters: a) volume ratio of mortar and 414 b) length and height of units. 415 6 Conclusions 416 A method for the homogenisation of composite materials has been combined with a method-of-cells 417 approach for the two-scale analysis of three-leaf masonry structures. It provides good accuracy in the 418 prediction of the compressive strength of three-leaf masonry and highlights crucial characteristics of these 419 structures with very low computational cost. The method requires a very dedicated approach in the 420 mechanical characterisation of the unit, mortar and fill properties, but compensates for this requirement 421 by providing an attractive alternative to finite element analysis for the determination of the mechanical 422