scieee AI-readable full text Open interactive document viewer

Double-frequency buck converter as a candidate topology for integrated envelope elimination and restoration applications in power supply of RFPAs

Saberkari, Alireza,Shirmohammadli, V.,Martínez García, Herminio,Alarcón Cot, Eduardo José

Abstract

This paper proposes the use of double-frequency (DF) buck converter architecture consisting of a merged structure of high and low frequency buck cells as a candidate topology for envelope elimination and restoration (EER) applications and integrated power supply of RF power amplifiers (RFPA) to obtain favorable tradeoffs in terms of efficiency, switching ripple, bandwidth, and tracking capability. It is shown that having two degrees of freedom in designing the DF buck helps to achieve high efficiency, low output ripples, and tracking capability with low ripples, simultaneously. A comparison analysis is done with regards to the mentioned performance indexes with the standard and three-level buck converters; in addition, the results are validated in HSPICE in BSIM3V3 0.35-µm CMOS process.

Full text

output ripple 1. INTRODUCTION RF power amplifiers (RFPAs) are the most significant power-consuming components in batteryoperated wireless communication systems and, hence, having a high efficient RFPA is one of the most important concerns. On the other hand, the newer generation of communication systems such as WCDMA, WLAN, or 4-G applications use spectrum efficient non-constant envelope modulations and require linear power amplifiers, which inherently suffer from lower efficiency to amplify the non-constant envelope signals [1]. Envelope elimination and restoration (EER) technique is one of the most encouraging solutions to improve the efficiency of RFPAs by employing the high-efficient RFPA [2]. This technique, which is shown in Figure 1(a), is based on the splitting of the input non-constant envelope signal to the baseband envelope and the constant envelope phase modulation signal. This separation can be done both digitally before modulating to the carrier frequency using the digital signal processor (DSP), which is available in transceiver systems, and analogically employing an envelope detector and a limiter. Then, each of these signals is amplified in a high efficient manner and then an efficient wide-bandwidth envelope tracking power converter (usually standard buck converter) modulates the supply voltage of the switched-mode RFPA, obtaining ideally an amplified replica of the input nonconstant envelope signal. Using an envelope tracking supply voltage with respect to the input signal *Correspondence to: Herminio Martinez-Garcia, Department of Electronics Engineering, Technical University of Catalonia (UPC), BarcelonaTech, Barcelona, Spain. † E-mail: [email protected] INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS AUTHOR'S FINAL DRAFT Double-frequency buck converter as a candidate topology for integrated envelope elimination and restoration applications in power supply of RFPAs Alireza Saberkari 1, * ,† , Vahideh Shirmohammadli 1 , Herminio Martinez 2 and Eduard Alarcón 2 1 Department of Electrical Engineering, University of Guilan, Rasht, Iran 2 Department of Electronics Engineering, Technical University of Catalunya, Barcelona, Spain SUMMARY This paper proposes the use of double-frequency (DF) buck converter architecture consisting of a merged structure of high and low frequency buck cells as a candidate topology for envelope elimination and restoration (EER) applications and integrated power supply of RF power amplifiers (RFPA) to obtain favorable tradeoffs in terms of efficiency, switching ripple, bandwidth, and tracking capability. It is shown that having two degrees of freedom in designing the DF buck helps to achieve high efficiency, low output ripples, and tracking capability with low ripples, simultaneously. A comparison analysis is done with regards to the mentioned performance indexes with the standard and three-level buck converters; in addition, the results are validated in HSPICE in BSIM3V3 0.35-μm CMOS process. Copyright © 2015 John Wiley & Sons, Ltd. KEY WORDS: buck converter; double-frequency; efficiency; envelope elimination and restoration (EER); will increase the overall efficiency in comparison to the fixed supply. As it is illustrated in Figure 1(b), for the case of constant supply voltage, the efficiency, which is proportional to ratio of the output signal amplitude to the supply voltage, can be very low if the signal amplitude is low, degrading the total efficiency to very low levels. In contrast, in the case of modulated supply voltage, thanks to the signal tracking capability of the efficient RFPA system, the overall efficiency will be enhanced. One of the key challenges for a successful realization of such systems is that the required bandwidth for the envelope path should be significantly larger than the original signal bandwidth and, hence, a wide-bandwidth envelope tracking switching power converter is needed. As a consequence, this means a high switching frequency, which is detrimental to efficiency. Several approaches have been proposed to address the tradeoff between the wide-bandwidth tracking capability and the efficiency in the envelope amplifier, including pulse-width modulated (PWM) [3–5], accelerated PWM [6] or delta-sigma modulated buck converters [7], a single-ended primary inductance converter (SEPIC) with average current-mode control [8], a cascade of buck and boost converters [9], a digitally controlled converter [10], a multiphase converter [11], a three-level [12, 13] or multilevel [14, 15] converters with flying capacitors, and multiple input buck converters [16, 17]. However, most of these approaches usually need complicated control systems. For example, although the three-level buck converter with flying capacitor for EER applications presented in [12], has advantages regarding lower output ripples, higher efficiency, and bandwidth, it needs an extra control circuitry for producing a constant voltage across the large flying capacitor. Otherwise, its performance will be degraded. Recently, the hybrid schemes of switching mode DC–DC converter and linear regulator in several combinations have been proposed in order to make a tradeoff between efficiency and bandwidth [18–23]. The series approaches of switching and linear stages presented in [18–20] consist of a standard and multilevel buck converter in series with a linear regulator, respectively. These structures have high bandwidth for envelope tracking applications, but both of them provide lower efficiency rather than conventional one stage buck converter because the whole load current flowing through the linear regulator causes high losses. The parallel scheme has been proposed as linearassisted switched-mode buck converters in [21–23]. In this approach, the low frequency part of the envelope signal flows through the switching DC–DC converter, and the high frequency part of the signal is amplified by the linear stage, which can react faster to the transient events. However, in Figure 1. (a) Envelope tracking system. (b) An output signal with fixed and modulated supply voltages. A. SABERKARI ET AL. order to achieve a proper efficiency, one of the difficulties of this approach is the output combiner block which causes a voltage drop between the input and output signals, resulting high power losses [22]. Furthermore, the band separation technique presented in [23] depends on the employed modulation and needs a complicated control system which results in more power losses and degraded efficiency. Double-frequency (DF) buck converter, shown in Figure 2, has been proposed for high voltage and high power applications [24]. This paper proposes the use of DF buck converter structure to obtain favorable tradeoffs in terms of efficiency, switching ripple, bandwidth, and tracking capability for on-chip integrated power supply of RFPAs when it is compared with the counterparts standard synchronous and three-level buck converters [25]. This structure is also suitable for energy harvesting applications because of the mentioned tradeoffs. The rest of the paper is organized as follows: Section 2 describes a brief review of the DF buck converter operation. Efficiency, output ripple, switching frequency, and element sizes tradeoffs in the DF buck are discussed in section 3, in comparison to the standard and three-level buck converters. Results, including the transient response comparison of different buck converters, and conclusion are in sections 4 and 5, respectively. 2. BRIEF REVIEW OF DF BUCK CONVERTER OPERATION In standard and three-level (3-L) buck converters shown in Figure 3, the average currents flowing through the switches are as below: Is¼DIL Isd ¼1DðÞIL (1) where Dis the duty cycle of the switching control signals. In order to enhance the steady-state and transient responses of the buck converter, the switching frequency should be increased, which increases the switching losses and degrades the efficiency, dramatically. In the DF buck converter, a controlled current source is added in parallel with the load to overcome this problem. The power stage of the DF buck converter is shown in Figure 2. It consists of two buck cells working at different frequencies; a high frequency buck (M 1 ,M 2 , and L) to enhance the dynamic performance, and a low frequency buck (M 1a ,M 2a , and L a ) to improve the efficiency of the converter. In our approach, MOSFET transistors are used for all four switches including the synchronous rectifiers (M 2 and M 2a ) in order to enhance the efficiency of the converter in low voltage operation. The average currents flowing through the high frequency switches of the DF buck are as below: I′ s¼DI LILa ðÞ I′ sd ¼1DðÞILILa ðÞ:(2) Figure 2. Double-frequency (DF) buck converter. DF BUCK CONVERTER FOR EER APPLICATIONS IN POWER SUPPLY OF RFPAS The currents through the high frequency switches are diverted through the low frequency ones, and as it is obvious from (2), the power losses of high frequency switches are lower than those in the standard and three-level buck converters. By choosing a proper ratio for the high and low frequencies of control signals, the low frequency inductor current (I La ) follows the high frequency one (I L ) and, hence, the currents through the high frequency switches are nearly zero. Thus, the converter can operate at very high frequency without degrading the efficiency, while its transient, and steady-state behavior will be improved. 3. PERFORMANCE TRADEOFFS IN DF BUCK CONVERTER In this section, the expressions for the efficiency, output current and voltage ripples, and output filter sizes are presented for the DF buck converter in comparison with the standard and threelevel ones. 3.1. Efficiency In order to analyze the efficiency of different buck converters, first, their power losses must be calculated. Because switching losses usually dominate the total loss, losses from the output capacitor and inductor are ignored here. Therefore, the conduction and switching losses are considered which form the total power loss of the buck converter. Additionally, a same turn-on (t on ) and turn-off (t off ) times are assumed for all switches. In the standard buck converter, the conduction and switching losses are as below [26]: Pscon ¼DVonIL Pss ¼1 2fsVinILton þtoff  Pdcon ¼1DðÞVfIL Psd ¼1 2fsVinILton þtoff  (3) where P scon and P ss are the conduction and switching losses of the main switch (M 1 ), and P dcon and P sd are the equivalent losses of the synchronous rectifier (M 2 ). V on and V f are the conduction voltages of M 1 and M 2 , respectively, and f s is the switching frequency. If a proper design reduces the conduction voltage of switches, the conduction losses can be neglected. Thus, the total switching losses of the standard buck converter, P s,std , is equal to: Ps;std ¼fsVinILton þtoff  :(4) Figure 3. (a) Standard synchronous, and (b) three-level buck converters. A. SABERKARI ET AL. In the DF buck converter, the average currents flowing through the high frequency and low frequency inductors are approximately 0.5I La and (I L 0.5I La ), respectively [24]. Hence, on the one hand, the losses of the high frequency cell are as below: Pscon;H¼0:5DVonILa Pss;H¼1 4fHVinILa ton þtoff  Pdcon;H¼0:51D ðÞ VfILa Psd;H¼1 4fHVinILa ton þtoff  (5) where P scon,H and P ss,H are the conduction and switching losses of the main switch (M 1 ), and P dcon,H and P sd,H are the equivalent losses of the synchronous rectifier (M 2 ). In the same way, the losses of the low frequency cell are: Pscon;L¼DVon IL0:5ILa ðÞ Pss;L¼1 2fLVin IL0:5ILa ðÞton þtoff  Pdcon;L¼1DðÞVfIL0:5ILa ðÞ Psd;L¼1 2fLVin IL0:5ILa ðÞ ton þtoff  (6) where P scon,L and P ss,L are the conduction and switching losses of the main switch (M 1a ), and P dcon,L and P sd,L are the equivalent losses of the synchronous rectifier (M 2a ). f H and f L are the switching frequencies of high and low frequency buck cells, respectively. The total conduction loss of the DF buck, which equals sum of the conduction losses of the high and low frequency cells, is approximately the same as the standard buck. Additionally, because I La is small in comparison with the inductor average current, the switching loss of the high frequency cell can be neglected and the total switching losses of the DF buck, P s,DF , is equal to: Ps;DF ¼fLVinILton þtoff  :(7) As it is obvious from (4) and (7), the efficiency of the DF buck is much better than the standard buck because of its lower frequency, which is because of the diverting the current to the low frequency cell. On the other hand, the conduction and switching losses of the three-level buck converter are as below: Pscon ¼2DVonIL Pss ¼1 2fsVin VC ðÞILton þtoff  ¼1 4fsVinILton þtoff  Pdcon ¼21DðÞVfIL Psd ¼1 2fsVin VC ðÞILton þtoff  ¼1 4fsVinILton þtoff  (8) where V C is the flying capacitor voltage which equals V in /2. The total conduction losses of the threelevel buck are twice the standard and DF buck converters. Additionally, the total switching losses of the three-level buck, P s,3-L , is as below: Ps;3L¼1 2fsVinILton þtoff  :(9) At the same output ripple, if we neglect the effect of conduction losses, the switching loss of the DF buck will be lower than that of the three-level one by choosing f L <1/2 f s . Therefore, the efficiency of DF BUCK CONVERTER FOR EER APPLICATIONS IN POWER SUPPLY OF RFPAS the DF buck depends on the low frequency buck cell. As a consequence, by lowering it, higher efficiency can be obtained rather than three-level buck. 3.2. Ripple comparison The high frequency inductor current ripple and the output voltage ripple for the DF buck converter are as below: ΔiDF ¼Vin 2Lf H 1DðÞD ΔvDF ¼Vin 16LCf 2 H 1DðÞD: (10) The maximum ripples occur at the duty cycle equal to 0.5, and their values are given by: ΔiDF;Max ¼Vin 8Lf H ΔvDF;Max ¼Vin 64LCf 2 H : (11) The low frequency inductor current ripple of the DF buck is as follows: Δia;DF ¼Vin 4LafL D:(12) As it can be seen, the output voltage and high frequency inductor current ripples of the DF buck depend on f H (the high frequency cell) while its efficiency depends on f L . For the standard buck converter, the ripples can be derived like (10) and (11) by substituting f s instead of f H . Because of the fact that, increasing the switching frequency of the high frequency cell does not affect the efficiency of DF, so the DF buck can have fewer ripples in comparison to the standard buck at the same efficiency. On the other hand, for the three-level buck, the ripples are equal to [12]: Δi3L¼Vin 2Lf s 0:5DðÞD0<D<0:5 Δi3L¼Vin 2Lf s 1DðÞD0:5ðÞ0:5<D<1 Δv3L¼Vin 32LCf 2 s 0:5DðÞD0<D<0:5 Δv3L¼Vin 32LCf 2 s 1DðÞD0:5ðÞ0:5<D<1: (13) The maximum ripples occur at duty cycles equal to 0.25 and 0.75 as below: Δi3L;Max ¼Vin 32Lf s Δv3L;Max ¼Vin 512LCf 2 s : (14) A. SABERKARI ET AL. In order to have a ripple comparison between different buck converters, the ripples of the DF buck in (11) are rewritten based on the frequency ratio of high and low frequency cells, M,(f H =Mf L ), as follows: ΔiDF;Max ¼Vin 8Lf L 1 M ΔvDF;Max ¼Vin 64LCf 2 L 1 M  2 : (15) Figure 4 shows the normalized output voltage and current ripples versus different duty cycles of the aforementioned buck converters for the same inductance and capacitance and for f s,std =f L = 0.5f s,3-L . Notice that the latter assumption is considered for comparing the output ripple of the buck converters with the same efficiency for all types. As it can be seen, the output voltage and current ripples of the DF buck are less than the standard buck for M≥2, and for Mequal to or more than 6 and 8, the DF output voltage and current ripples are less than the three-level buck, respectively. Notice that f L can be reduced to less than half of the switching frequency of the standard and threelevel buck converters to enhance the efficiency, and simultaneously, Mcan be increased to achieve less output ripples in comparison to the mentioned converters. Indeed, having two degrees of freedom in designing the DF buck helps to obtain high efficiency and low output ripples, simultaneously. 3.3. Bandwidth For a more fair comparison, open-loop bandwidths of standard, three-level, and dual-frequency buck converters are calculated and compared in this section. Because the output filter (Land C)of converters mentioned above are equal, so by replacing fc¼1=2πffiffiffiffiffiffi LC pinto the maximum voltage ripple equations of the three converters considered here, the following relations can be derived: ΔVstd;max ¼π2Vin 16 fc;stan fs  2 ΔVDF;max ¼π2Vin 16 fc;DF fL  21 M2 ΔV3L;max ¼π2Vin 128 fc;3L fs  2 : (16) Figure 4. Normalized output voltage and current ripple comparison for different buck converters by considering the same efficiency condition. DF BUCK CONVERTER FOR EER APPLICATIONS IN POWER SUPPLY OF RFPAS By assuming the same efficiency (that is, f s,std =f L = 0.5f s,3-L ) and same voltage ripples, the open-loop bandwidth (f C ) of these three converters can be obtained as below: fc;3L¼4ffiffiffi 2 pfc;std fc;DF ¼M 4ffiffiffi 2 pfc;3L fc;DF ¼Mf c;std: (17) As a result, for Mequal to or greater than 2 and 6, the open-loop bandwidth of DF buck is more than that of standard and three-level buck converters, respectively. Moreover, because it is Figure 5. Output voltage transient response comparison for: (a) load step-up from 5 to 10 Ω; and (b) load step-down from 10 to 5 Ω. Figure 6. (a) Steady-state output voltage ripple comparison and (b) steady-state output current ripple comparison. A. SABERKARI ET AL. possible to increase the high frequency of the DF buck without degrading the efficiency, the filter element sizes can be reduced significantly, and hence the open-loop bandwidth of the DF can be increased. Figure 7. Power supply ripple for different types of buck converters. Figure 8. Efficiency comparison of the three buck converters. Figure 9. Test bench of the DF buck converter for evaluating the input signal tracking capability. DF BUCK CONVERTER FOR EER APPLICATIONS IN POWER SUPPLY OF RFPAS 5. CONCLUSION Using the DF buck converter structure as a candidate topology for integrated power supply of RFPAs and EER applications is proposed in this paper. Diverting the high frequency current to the low frequency cell in the DF buck, will result in obtaining favorable tradeoffs in terms of efficiency, switching ripple, bandwidth, and envelope tracking capability. It is shown that having two degrees of freedom in designing the DF buck helps to obtain high efficiency and low output ripples, simultaneously. Performance analysis is done with regards to the mentioned indexes, and the results, validated in HSPICE in BSIM3V3 0.35-μm CMOS process, reveal the advantages of the aforementioned buck in comparison to the standard and three-level buck converters. REFERENCES 1. Stauth J, Sanders S. Dynamic power supply design for high efficiency wireless transmitters. Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, Tech.Rep. UCB/EECS-2006-72, 2006. 2. Raab FH, Asbeck P, Cripps S, Kenington PB, Popovic ZB, Pothecary N, Sevic JF, Sokal NO. Power amplifiers and transmitters for RF and microwave. IEEE Transactions on Microwave Theory and Techniques 2002; 50(3):814–826. 3. Midya P, Haddad K, Connell L, Bergstedt S, Roeckner B. Tracking power converter for supply modulation of RF power amplifiers. Proceedings IEEE Power Electronics Specialists Conference (PESC’01) 2001; 1:1540–1545. 4. Staudinger J, Gilsdorf B, Newman D, Norris G, Sadowniczak G, Sherman R, Quach T. High efficiency CDMA RF power amplifier using dynamic envelope tracking technique. Proceedings IEEE MTT-S International Microwave Symposium Digest 2000; 2:873–876. 5. Abedinpour S, Deligoz K, Desai J, Figiel M, Kiaei S. Monolithic supply modulated RF power amplifier and DC–DC power converter IC. Proceedings IEEE MTT-S International Microwave Symposium Digest. 2003; 1:A89–A92. 6. Chen JJ, Hwang BH, Jhang YC, Hwang YS, Yu CC. A new fast-response buck converter using accelerated pulsewidth-modulation techniques. International Journal of Circuit Theory and Applications 2013; 41(8):854–865. 7. Tormo AG, Poveda A, Alarcon E, Guinjoan F. Design-oriented characterisation of adaptive asynchronous ΣΔ modulation switching power amplifiers for bandlimited signals. Proceedings IEEE International Symposium on Circuits and Systems (ISCAS’09) 2009:2882–2885. 8. Anderson DR, Cantrell WH. High-efficiency high-level modulator for use in dynamic envelope tracking CDMA RF power amplifiers. Proceedings IEEE MTT-S International Microwave Symposium Digest 2001; 3:1509–1512. 9. Midya P, Haddad K, Miller M. Buck or boost tracking power converter. IEEE Power Electronics Letters 2004; 2(4):131–134. 10. Yousefzadeh V, Wang N, Popovic Z, Maksimovic D. A digitally controlled DC/DC converter for an RF power amplifier. IEEE Transactions on Power Electronics 2006; 21(1):164–172. 11. Qiu Y, Xu M, Yao K, Sun J, Lee FC. Multifrequency small-signal model for buck and multiphase buck converters. IEEE Transactions on Power Electronics 2006; 21(5):1185–1192. 12. Yousefzadeh V, Alarcon E, Maksimovic D. Three-level buck converter for envelope tracking in RF power amplifiers. Proc. IEEE Applied Power Electronics Conference (APEC’05) 2005; 3:1588–1594. 13. Rodrigues JP, Mussa SA, Heldwein ML, Perin AJ. Three-level ZVS active clamping PWM for the DC–DC buck converter. IEEE Transactions on Power Electronics 2009; 24(10):2249–2258. 14. Meynard TA, Foch H. Multi-level conversion: high voltage choppers and voltage-source inverters. Proceedings IEEE Power Electronics Specialists Conference (PESC’92) 1992; 1:397–403. 15. Meynard TA, Foch H, Thomas P, Courault I, Jakob R, Nahrstaedt M. Multicell converters: basic concepts and industry applications. IEEE Transactions on Industrial Electronics 2002; 49(5):955–964. 16. Rodrıguez M, Miaja PF, Rodrıguez A, Sebastian J. A multiple-input digitally controlled buck converter for envelope tracking applications in radiofrequency power amplifiers. IEEE Transactions on Power Electronics 2010; 25(2):369–381. 17. Huang H, Bao J, Zhang L. A MASH-controlled multilevel power converter for high-efficiency RF transmitters. IEEE Transactions on Power Electronics 2011; 26(4):1205–1214. 18. Gjanci J, Chowdhury MH. A hybrid scheme for on-chip voltage regulation in system-on-a-chip (SOC). IEEE Transactions on VLSI System 2011; 19(11):1949–1959. 19. Vasic M, Garcıa O, Oliver JA, Alou P, Dıaz D, Cobos JA. Multilevel power supply for high-efficiency RF amplifiers. IEEE Transactions on Power Electronics 2010; 25(4):1078–1089. 20. Modi S, Balsara P, Eliezer O. Envelope tracking using transient waveform switching shaping supply modulation. International Journal of Circuit Theory and Applications 2013. doi:10.1002/cta. 21. Kim I, Woo YY, Moon J, Kim J, Kim B. High-efficiency hybrid EER transmitter using optimized power amplifier. IEEE Transactions on Microwave Theory and Techniques 2008; 56(11):2582–2593. 22. Miaja PF, Rodrıguez M, Rodrıguez A, Sebastian J. A linear assisted DC/DC converter for envelope tracking and envelope elimination and restoration applications. IEEE Transactions on Power Electronics 2012; 27(7):3302–3309. 23. Yousefzadeh V, Alarcon E, Maksimovic D. Band separation and efficiency optimization in linear-assisted switching power amplifiers. Proceedings IEEE Power Electronics Specialists Conference, (PESC’06) 2006:1–7. A. SABERKARI ET AL. 24. Du X, Zhou L, Tai HM. Double-frequency buck converter. IEEE Transactions on Industrial Electronics 2009; 56(5):1690–1698. 25. Shirmohammadli V, Saberkari A, Alarcon E. Performance analysis of dual-frequency buck converter for integrated power management. Proceedings IEEE. Power Electronics and Drive Systems and Technologies Conference (PEDSTC’14) 2014:402–407. 26. Mohan N, Undeland TM, Robbins WP. Power Electronics: Converters, Applications, and Design (3 rd edn). Wiley: New York, 2003. 27. Marco L, Alarcon E, Maksimovic D. Effects of switching power converter nonidealities in envelope elimination and restoration technique. Proceedings IEEE International Symposium on Circuits and Systems (ISCAS’06) 2006:3137–3140. DF BUCK CONVERTER FOR EER APPLICATIONS IN POWER SUPPLY OF RFPAS