Full text
Final Degree Thesis Industrial Engineering (GETI) Self-consumption installation sizing and design Report April 19, 2023 Autor: Adriana Álvaro Martínez Tutor: Alba Ramos Cabal Call: April 2023 Escola Tècnica Superior d’Enginyeria Industrial de Barcelona
Self-consumption installation sizing and design with renewable energies page 1 Abstract The present project consists in the design and sizing of a self-consumption renewable energy based installation for the common areas of a building from the Barcelona city, in Spain. The technologies chosen for the study are mini-wind and PV energy. Therefore, the wind and solar resource in the selected location has been studied along with an analysis of the electric consumption patterns of the building. A software for calculations of hybrid facilities has been used to make a customized proposal with the main equipment needed for the facility. This proposed installation aims to help attend the demand and reduce the energy consumption bill. The project results indicate that the proposed installation covers the demand in a considerable part and it helps achieve significant annual savings. Furthermore, the payback period is around 4-5 years, which is considered to be a reasonable time. While relying on a more sustainable energy source and thus reducing their carbon emissions, the owners of this building would be saving money at the same time. Resum El present projecte consisteix en el disseny i dimensionament d’una instal·lació d’energies renovables d’autoconsum per a les zones comuns d’un edifici situat a la ciutat de Barcelona, Espanya. Les tecnologies seleccionades per a l’estudi són la mini-eòlica i l’energia fotovoltaica. Per tant, s’ha estudiat el recurs eòlic i solar en la ubicació seleccionada juntament amb una anàlisi dels patrons de consum elèctric a l’edifici. S’ha utilitzat un programari per al càlcul d’instal·lacions híbrides per fer una proposta personalitzada amb els principals equips necessaris per a la instal·lació. Aquesta instal·lació proposada té com a objectiu ajudar a suplir la demanda i reduir la factura de la comunitat de veïns. Els resultats del projecte indiquen que la instal·lació proposada cobreix una part considerable de la demanda i ajuda a aconseguir estalvis anuals significatius. A més, el període de retorn és d’al voltant de 4-5 anys, que es considera un temps raonable. Al mateix temps que es passa a dependre d’una font d’energia més sostenible i, per tant, es redueixen les emissions de carboni, els propietaris d’aquest edifici estarien estalviant diners anualment. Resumen El presente proyecto consiste en el diseño y dimensionamiento de una instalación de energías renovables de autoconsumo para las zonas comunes de un edificio ubicado en la ciudad de Barcelona, España. Las tecnologías seleccionadas para el estudio son la mini-eólica y la energía fotovoltaica. Por lo tanto, se ha estudiado el recurso eólico y solar en la ubicación seleccionada junto con un análisis de los patrones de consumo eléctrico en el edificio. Se ha utilizado un software para el cálculo de instalaciones híbridas para hacer una propuesta personalizada con los principales equipos necesarios para la instalación. Esta instalación propuesta tiene como objetivo ayudar a suplir la demanda y reducir la factura de la comunidad de vecinos. Los resultados del proyecto indican que la instalación propuesta cubre una parte considerable de la demanda y ayuda a lograr ahorros anuales significativos. Además, el período de retorno es de alrededor de 4-5 años, lo cual se considera un tiempo razonable. Al mismo tiempo que pasando a depender de una fuente de energía más sostenible y, por lo tanto, reducir sus emisiones de carbono, los propietarios de este edificio estarían ahorrando dinero anualmente.
page 2 Report
Contents Abstract ............................................... 1 Contents ............................................... 4 1 Introduction ........................................... 7 1.1 Project context and motivation ............................. 7 1.2 Objectives and project scope ............................... 9 1.3 Project planning ...................................... 9 2 Theoretical framework: wind and solar energy technologies .............. 12 2.1 Wind energy technology ................................. 12 2.1.1 Wind power generators equipment ....................... 12 2.1.2 Operating principle ................................ 12 2.1.3 Output Power ................................... 15 2.1.4 Other wind energy technologies ........................ 17 2.2 PV technology ....................................... 20 2.2.1 PV system equipment .............................. 20 2.2.2 PV cell operating principle ........................... 21 2.2.3 Output power ................................... 22 3 Case of study: resources and demand ............................ 23 3.1 Resource analysis ..................................... 23 3.1.1 Location ...................................... 23 3.2 Wind resource ....................................... 24 3.3 Solar resource ....................................... 26 3.4 Electric demand ...................................... 29 4 Installation design ....................................... 32 4.1 Wind Turbine Installation ................................ 32 4.2 PV installation ....................................... 34 5 Installation sizing with HOMER software ......................... 43 5.1 Input: Resources ..................................... 43 5.1.1 Wind and Solar Resources ............................ 43 5.1.2 Temperature .................................... 44 5.1.3 Economic parameters .............................. 45 5.2 Input: Equipment to consider .............................. 45 5.2.1 Wind Turbine Generator ............................. 45 5.2.2 PV panels ..................................... 46 5.2.3 Inverter for the PV array ............................. 47 5.2.4 Grid Inputs .................................... 48 5.3 Simulations outputs .................................... 49 5.3.1 General comparison of results .......................... 50 6 Facility performance ...................................... 55 6.1 Energy yield ........................................ 55 6.2 Economic analysis ..................................... 58 3
page 4 Report 7 Budget .............................................. 62 8 Environmental study, social and gender equality impact ................. 63 Conclusions ............................................. 64 Bibliography ............................................ 67 Annexes ............................................... 68
List of Figures Figure 1.1.1 Electric energy generation source 2021 in Spain. Source: [1] ....... 7 Figure 1.1.2 Percentage of renewable generation over total generation per countries. Source: [1] ................................... 8 Figure 1.3.1 Gantt chart for project planning ....................... 10 Figure 2.1.2.1 Air flowing into a wind turbine. Source: [3] ................ 13 Figure 2.1.2.2 Triangle of velocities .............................. 13 Figure 2.1.2.3 Design angles .................................. 14 Figure 2.1.2.4 Lift and Drag .................................. 14 Figure 2.1.2.5 Velocities and forces acting on a blade. Source: [2] ............ 15 Figure 2.1.3.1 Variation of Cp relative to TSR. Source: [5] ................. 16 Figure 2.1.3.2 Typical WTG power curve. Source: [5] ................... 17 Figure 2.1.4.1 VAWTs types. Source: [6] ........................... 18 Figure 2.1.4.2 Vortex Bladeless technology. Source: [7] .................. 19 Figure 2.1.4.3 Tuning system diagram. Source: [7] ..................... 20 Figure 2.2.1.1 PV system equipment. Source: [5] ...................... 20 Figure 2.2.2.1 PV cell. Source: [5] .............................. 21 Figure 2.2.3.1 I-V curve for different conditions. Source: [5] ............... 22 Figure 3.1.1.1 Aerial view of the selected location. Source: [8] .............. 23 Figure 3.1.1.2 Closer view of the rooftop. Source: [8] ................... 24 Figure 3.1.1.3 Available surface measurements ....................... 24 Figure 3.2.1 Wind Histogram ................................ 26 Figure 3.3.1 Hourly average irradiation per month .................... 27 Figure 3.3.2 Hourly average irradiation per month (2) ................. 28 Figure 3.4.1 Monthly energy consumed .......................... 29 Figure 3.4.2 Monthly energy consumed comparison ................... 30 Figure 3.4.3 Daily consumption pattern .......................... 30 Figure 3.4.4 Energy consumed in each season ...................... 31 Figure 4.1.1 Place for the wind turbine. Source [8] .................... 32 Figure 4.1.2 Mini wind turbine with passive yaw control system. Source [11] . . . . 33 Figure 4.1.3 Wind Rose for the selected location ..................... 33 Figure 4.2.1 Angle schema .................................. 35 Figure 4.2.2 Sun-chart. Source [14] ............................. 36 Figure 4.2.3 Solar angles. Source [13] ........................... 36 Figure 4.2.4 In-plane irradiation at 38ºat the selected location. Source [15] . . . . . 37 Figure 4.2.5 Daily Average Solar Peak Hours at 38ºper month ............. 37 Figure 4.2.6 Daily Average Solar Peak Hours at 30ºper month ............. 38 Figure 4.2.7 Schema for shadow calculation South panel orientation ......... 38 Figure 4.2.8 Panel configurations .............................. 41 Figure 5.1.1.1 Data required by HOMER .......................... 43 Figure 5.1.2.1 Monthly average temperature. Source [9] ................. 44 Figure 5.2.1 Equipment squeme .............................. 45 Figure 5.2.1 Grid Rates .................................... 49 Figure 5.3.1.1 South & Horizontal configuration ...................... 50 Figure 5.3.1.2 South & Vertical configuration ........................ 51 Figure 5.3.1.3 South-West & Horizontal configuration ................... 52 Figure 5.3.1.4 South-West & Vertical configuration ..................... 53 Figure 6.1.1 Monthly average energy production: PV and grid ............. 55 5
Figure 6.1.2 Monthly average energy source for the electric demand: PV or grid . . 56 Figure 6.1.3 Total PV production through the year: 7716 kWh ............. 57 Figure 6.1.4 Fall and winter months daily average pattern ............... 57 Figure 6.1.5 Spring and summer months daily average pattern ............. 58 Figure 6.2.1 Save percentage compared to situation without PV array ......... 59 Figure 6.2.2 Estimated amount to pay monthly ...................... 59 Figure 6.2.3 Nominal project cash-flow (without applying discount rate) ...... 60 Figure 6.2.4 Discounted project cash-flow applying discount rate ........... 61 Figure 8.1 Rate of STEM graduates in Europe and Spain. Source [21] ........ 63 List of Tables Table 1.3.1 Tasks from Gant chart ............................. 11 Table 4.2.1 Minimum distance between panel lines (Dec 21st) [mm] ........ 39 Table 4.2.2 Parameters values (Dec 21st) ......................... 40 Table 5.1.1.1 Parameters introduced in HOMER ..................... 44 Table 5.1.3.1 Economic parameters introduced in HOMER ............... 45 Table 5.2.1.1 Wind Turbine data sheet features. Source [11] ............... 46 Table 5.2.2.1 PV panels data sheet features. Source [18] ................. 47 Table 5.2.2.2 PV panel structures features. Source [18] .................. 47 Table 5.2.3.1 Inverter features. Source [18] ......................... 48 Table 5.3.1.1 South & Horizontal HOMER distinguishing parameters ......... 50 Table 5.3.1.2 South & Vertical HOMER distinguishing parameters ........... 51 Table 5.3.1.3 South-West & Horizontal HOMER distinguishing parameters ...... 52 Table 5.3.1.4 South-West & Vertical HOMER distinguishing parameters ........ 53 Table 5.3.1.5 Simulations general results .......................... 54 Table 6.1.0.1 Parameters PV array performance ...................... 58 Table 7.1 Project Costs .................................. 62 6
Self-consumption installation sizing and design with renewable energies page 7 1 Introduction 1.1 Project context and motivation Two of the major issues that are being faced in today context are climate change and the rising cost of energy resources. One way (not the only one and not enough in itself) to fight these issues is the transition to renewable sources. Accelerating this transition will help both reduce carbon footprint in the long term and reduce the cost of electric energy generation. Is important not only to generate from clean sources but also to maximize energy efficiency to take the most leverage from what is produced. The personal motivation for this project is to participate in this process of energy decarbonization and start doing so in a immediate surroundings: the actual building of the current author dwelling. In Spain the electric demand in 2021 was of 256,546 GWh, and the electric energy generation structure is displayed in Figure 1.1.1 Figure 1.1.1: Electric energy generation source 2021 in Spain. Source: [1] One can notice that almost half of the electric energy production relies on renewable sources, though only half is not enough. The comparison to other European countries in the percentage of renewable generation in front total generation can be observed in the Figure 1.1.2 below:
page 14 Report referred as pitch angle and is the angle between the rotor plane and the profile chord. φis the sum of both. Figure 2.1.2.3: Design angles The operating principle of a wind turbine blade is very similar to that of a plane wing. The shape of the blade is actually a wing profile which induces low pressure in the more curved part, and high pressure on the other side due to Bernoulli’s principle [4](see Equation 2.1.2.5). The shape of the wing is more curved on the upper side so the velocity is higher on this side, inducing lower pressure and the other way around in the less curved wing side. This pressure difference generates two forces: one component perpendicular to the flow (Lift) and another component parallel to the flow (Drag) as it can be seen in Figure 2.1.2.4. 1 2·ρ·U2+p+ρgh =const (2.1.2.5) Figure 2.1.2.4: Lift and Drag For different angles of attack the lift and drag forces change. It is of interest to find the angle that
Self-consumption installation sizing and design with renewable energies page 15 maximizes the lift respect to the drag so that the maximum torque can be generated to rotate the blades. The resultant force (FRS) between lift (FA) and drag force (FR) is divided into the tangential (FT) and axial component (FS). In the Figure 2.1.2.5 can be observed the velocities and forces mentioned [5]. Figure 2.1.2.5: Velocities and forces acting on a blade. Source: [2] 2.1.3 Output Power The WTG 2efficiency is commonly referred as power coefficient and denoted by Cp. Is defined as: Cp=Pe(v) Pavail(v)(2.1.3.1) Being Pethe electric output power and Pavail the power available in the wind. As it has been seen, the power available in the wind depends on its speed v. Let’s define the Tip Speed Ratio TSR: TSR =λ=ωT·R v(2.1.3.2) where ωTis the rotational speed of the blades in rad/s, Rits radius and vthe wind speed in 2WTG stands for Wind Turbine Generator
page 16 Report m/s. The TSR has a dependency with the WTG efficiency Cp[5], and there is a certain value for TSR that maximizes the power coefficient (see Figure 2.1.3.1) Figure 2.1.3.1: Variation of Cp relative to TSR. Source: [5] For achieving this value, if the wind speed increased, the rotational speed of the blades should increase along with it. Obviously, as the wind speed increases the output power does so as well, but there is a limit to that. For high wind speeds the blades would rotate at a very high velocity and this is problematic for structural (would cause undesirable vibrations) and electrical reasons (the power that can handle the generator is also limited). For that reason when wind speed reaches a certain value, the pitch angle is changed (the blades are turned on themselves) to decrease efficiency on purpose and thus the output power. This method of regulating the output power is known as pitch regulation. WTG are designed for a certain wind speed and power output: rated speed and rated power. Each WTG has a power curve which relates the wind speed with the output power (see Figure 2.1.3.2). For very low (cut-in) and very high (cut-out) wind speeds the WTG is usually stopped. In between the cut-in and rated speed the rotational speed of the blades changes and so does the generator angular speed. Therefore, an electrical generator that supports variable speed is required.
Self-consumption installation sizing and design with renewable energies page 17 Figure 2.1.3.2: Typical WTG power curve. Source: [5] 2.1.4 Other wind energy technologies Among wind energy technologies, others than the conventional ones could be considered, for instance Vertical Axis Wind Turbines (VATWs) of the Vortex Bladeless technology. VAWTsusegenerallythesameaerodynamicsprinciplesashorizontalaxiswind turbines (HAWTs) being the main difference that the blade rotation axis is vertical. The trends for this technology are not unified and many different designs exists, though the main types are: Savonius, Darrieus and H-Rotor type [6]. •Savonius: dragdrivenwindturbinewith twocupsinoppositedirectionsandamainshaft. One cup at a time catches the wind and causes the shaft to rotate. The operating principle of this one differs from HAWTs 3because is the drag force that causes the rotation. See Figure 2.1.1a •Darrieus: this one includes both Curved-Bladed and Straight-Bladed and are lift force driven wind turbines. See Figure 2.1.1b The blades are aerofoil shaped so the operating principle is more similar to that explained earlier in 2.1.2. •H-Rotor: similar to Darrieus Straight-Bladed one. See Figures 2.1.1c and 2.1.1d 3Horizontal Axis Wind Turbine
page 18 Report (a) Savonius type (b) Darrieus curved blade (c) Darrieus straight blade (d) H-Rotor type Figure 2.1.4.1: VAWTs types. Source: [6] The main advantages/disadvantages for this type of WTG are: •Less noise •Smaller swept area (more respectful with bird-life) •Good efficiency in small turbines •Lower efficiencies than HAWTs in general •Not unified design/trend •More expensive It has been said for many years now that VAWT were a good option for urban locations, but truth is that since there is not a clear trend for its design (still a lot of research for different proposals), they are not yet very common among cities or private houses as, i.e., PV panels. The Vortex Bladeless technology one extracts energy from the wind in a completely different way: to start with, it does not even have blades. The energy extraction is based on vortex induced vibration resonance [7].
Self-consumption installation sizing and design with renewable energies page 19 The main structure is a vertical cylinder anchored on the bottom and unconstrained on the top so it can vibrate (Figure 2.1.2a). When exposed to a wind flow, vortex 4are created at the rear of the cylinder and they keep detaching from the cylinder. This is known as vortex shedding (Figure 2.1.2b. This causes a pressure fluctuation that induces a movement in the cylinder in a perpendicular direction to the air flow direction (vortex induced vibration). When the vortex shedding frequency is similar to the natural oscillatory frequency of the cylinder, then the aerolastic phenomenon of resonance occurs, and both movements feedback each other, causing the structure to vibrate. The kinetic energy of this movement is the one converted to electric energy. (a) Main structure (b) Vortex shedding Figure 2.1.4.2: Vortex Bladeless technology. Source: [7] The vortex shedding frequency depends on the wind velocity and this is a very changing factor, but the cylinder natural frequency is only one. Therefore, if we want this phenomenon to occur for a wide range of wind speeds so that we can extract energy at the maximum amount of time possible, then we need the cylinder natural frequency to change with the wind speed. This is achieved by adding a pair of permanent magnets with the same poles facing each other. The repelling force that appears between them depends on the distance between them so they behave as a compressed spring with a elasticity constant dependent on the displacement. Thus, the oscillatory frequency increases with the oscillation amplitude (and this amplitude increases with wind force). This tuning system can be represented by the diagram in Figure 2.1.4.3. This same magnets are used for the electromagnetic induction for electricity yield. 4in fluid dynamics is a region in a fluid in which the flow revolves around an axis line (whirlwinds of turbulence).
page 20 Report Figure 2.1.4.3: Tuning system diagram. Source: [7] This technology is not yet in the market but it seems very suitable for small and on-site energy production as the urban location that is to be considered in this project. The advantages that it offers compared to conventional wind turbines are: •Much less noise: for urban installations, for instance in city building’s rooftops, this is a main advantage to be considered. •Much less maintenance: when installing a self-consumption installation at home, the less maintenance the better. •Respectful with bird wildlife: this is an advantage not only for urban installations but for wind farms as well. 2.2 PV technology 2.2.1 PV system equipment The basics components of a PV system are represented in the Figure 2.2.1.1 Figure 2.2.1.1: PV system equipment. Source: [5] The MPPT is an electronic device that maximizes the output power of the PV array at the given temperature and irradiance conditions. The inverter is required because the PV cell generates DC power and it is needed to be converted to AC to connect it to the grid. To be able to connect it to the grid a transformer is also required to transform this AC output voltage to an adequate level.
Self-consumption installation sizing and design with renewable energies page 21 2.2.2 PV cell operating principle For the same reasons mentioned in the subsection 2.1, a good understanding of the PV technology will help both to analyse the solar resource and the choice making of the panels and the other technologies. The mostwidely used material for PV cells is silicon, which has 14 electrons, 4 of which are in the valence band. Each silicon atom makes 4 covalent bonds with 4 neighbour atoms to share one electron with each one of them so that they can achieve having 8 electrons in the valence band. When exposed to sunlight, photons interact with these bonds and transfer them their energy. If the energy carried by the photons is higher than the silicon energy gap band (1.12 eV) then the silicon electrons can be displaced to the conduction band, but they would return to the valence band after a while. An electric field is needed to keep these electrons in the conduction band. For that purpose silicon is doped. On one crystal side silicon is doped with, for instance, boron, which has one less electron than silicon. On the other crystal side is injected, for instance, phosphorus, which has one more electron than silicon. In this way a positive and a negative zone are created respectively, the so-called pand nzones. In the nzone the unbounded electrons are abundant while in the pthere are more bonds missing, the so-called holes. They are not real holes, is a way of referring to this positive charge. In the interface the PN-junction is created when some of the free electrons tend to go from the n-zone to the p-zone to occupy some of the mentioned holes. Thus a neutral region with nonmoving charges is formed and it acts as a electric dipole. Now, when this crystal is exposed to sunlight, the free electrons generated will follow the direction imposed by the electric field created. If we electrically connect both pand nsides, we will have electric current. In the Figure 2.2.2.1 a PV cell and its parts are represented. Figure 2.2.2.1: PV cell. Source: [5]
page 22 Report 2.2.3 Output power Let’s define in the first place some useful concepts: •G - Irradiance: the solar power measured in W/m2 •STC - Standard Test Conditions: the PV modules factory tests are at the conditions of irradiance Gr=1000 W/m2and temperature θr=25 ℃(T=298 K).5 •Pp- Peak Power: the output DC power under STC. •Vr MP - Output voltage at maximum power at STC. •Ir MP - Output current at maximum power at STC. Temperature and irradiance are the two main factors that affect the output DC power of a PV module. In the Figures 2.2.1a and 2.2.1b can be observed how the output power increases with irradiance and how it decreases with high temperatures, respectively. (a) I-V curve for different Irradiance (G) (b) I-V curve for different temperatures Figure 2.2.3.1: I-V curve for different conditions. Source: [5] With the given conditions of temperature and irradiance the MPPT computes the voltage (VMP ) that maximizes the PV modules output DC power and thus assure that the modules operate at the optimum point for the given conditions. 5The superindex rrefers to STC
Self-consumption installation sizing and design with renewable energies page 23 3 Case of study: resources and demand 3.1 Resource analysis 3.1.1 Location The selected location is a building in the Eixample district in Barcelona, Spain. It is a building complex with three identical blocks. The aerial view of it can be seen in the Figure 3.1.1.1. Each block has 6 stairwells and each one of them has 11 floors and in each floor there are two apartments. It has been estimated that in each one of them live an average of 2.75 persons, which results in 61 people per block approximately (60.5). The aim of the project is to help compensate the common areas energy consumption (lighting and elevators), which could be considered roughly independent of the number of people living in each building. Hence, and taking into account that each block is identical (in terms of available space), the project calculations will be done for just one block and assuming that they could be easily extrapolated to the other blocks. Figure 3.1.1.1: Aerial view of the selected location. Source: [8] The coordenates for this location are aproximately: Latitude: 41º38’, Longitude: 2º15’ [8]. The building has a great surface available in the rooftop, a more detailed view can be seen in Figure 3.1.1.2.
page 30 Report Figure 3.4.2: Monthly energy consumed comparison With this factor and the auxiliary hourly consumption data throughout a year, the hourly consumption pattern is extrapolated for the case study. The result is displayed in Figure 3.4.3 Figure 3.4.3: Daily consumption pattern One can notice that the consumption in the winter and fall months is a bit higher than in spring and summer. See Figure 3.4.4. If the data corresponded to a dwelling consumption, this difference could be attributed to heating usage, but in the case study the heating system is not being considered, the data is only accounting for elevator and lighting. The explanation for this fact is that these are the months with more daylight: some lights are programmed to be switched on only during certain periods of the day. These periods are established different among win-
Self-consumption installation sizing and design with renewable energies page 31 ter/fall and spring/summer seasons. In any case, however, the energy consumed throughout does not vary a great deal, and the differences can be attributed to the measurement or the approximations done. Figure 3.4.4: Energy consumed in each season
page 32 Report 4 Installation design 4.1 Wind Turbine Installation For the wind turbine installation some of the considerations to be taken into account are: •Position and surroundings •Turbine orientation •Vertical vs horizontal axis Given the available space it has been decided to place the wind turbine in one of the sides of the booth in the rooftop. See Figure 4.1.1. It has been decided this way for the following reasons: – This side of the booth is shadowed most time of the day, so there is no point in installing PV panels on this surface. – On top of the booth is a completely shadow free area so it has been reserved this space for the PV panels. – The wind turbine is more likely to need maintenance and the top of the booth is less accessible. – This position let the turbine far enough from the rest of the roof elements so that the wind flow is not excessively disturbed.7 Figure 4.1.1: Place for the wind turbine. Source [8] 7The exact way in which the wind flow is disturbed has not been studied because it is not in the scope of the project. Usually this study is carried out wind farms of large wind turbines, not small home installations.
Self-consumption installation sizing and design with renewable energies page 33 The turbine orientation has to do with the most likely wind flow direction. There are some wind turbines that include yaw control systems that enable the turbine to automatically face the wind direction so that the power that is extracted from the wind is maximized. In large wind turbines this yaw control is usually active: a device monitor the wind flow direction and activates the yaw rotating system in consequence. For mini wind turbines yaw control is usually passive: the turbine nacelle includes a rear overhang that tends to align with the wind direction so that it forces the turbine blades to be in the desirable position, perpendicular to the wind flow. Figure 4.1.2: Mini wind turbine with passive yaw control system. Source [11] Some of the mini wind turbine models that are being considered in the facility have this passive yaw control. Nevertheless, if the orientation needed to be fixed, the wind direction has been studied in the selected location [9] and a wind rose has been build, representing the percentage of times that the wind comes from each direction throughout a year. See Figure 4.1.3 Figure 4.1.3: Wind Rose for the selected location
page 34 Report It is notices that the most common direction is south-west, therefore, if there is no yaw passive control available, the turbine orientation will be facing south-west. Regarding the wind turbine axis type, there is no preference in the first instance, although it is true that, as mentioned in 2.1.4, the designs for VAWTs are not unified and there is more supply for HAWTs, as well as being the latter more affordable in general. 4.2 PV installation Some of the design considerations to be taken into account for the PV installation are: •Panel Orientation: south or parallel to the rooftop •Panel Layout: horizontal or vertical •Panel Inclination •Distance between panels •Number of panels •Panel Connection: parallel or series Since the location is in the northern hemisphere, the best orientation would be facing south to maximize the number of hours the sunlight strikes the PV panels. This will be of course one of the orientations to be considered. But given that the building is facing southwest, a panel configuration facing southwest will be considered too. It is a simpler configuration in terms of space distribution as well as giving the possibility of introducing maybe some more panels. Both will be simulated with HOMER software [12] to decide which one could be better in terms of energy yield and ease of installation. The number of lines and panels per line will have to take into account the panel sizes and suitable panel structures. To decide the panel layout, one has to check which are the suitable support structures available in the market, as well as considering which layout will make more panels fit in the available space. The panel layout will affect the shadowing and therefore the minimum distance between panels. The chosen layout will be argued taking into a account all the panel factors. Regarding the inclination of the panels, in general for isolated systems the generation is maximized for the winter months so that even in the worst8months the generation is as close to the demand as possible. In our case the aim is to generate as much as possible because the most likely situation is that the demand is always greater than the generation. If given the case in which the energy yield is greater than the demand, then the surplus will be injected to the grid and an economic benefit will be generated from that. To maximize the generation for any given day means to choose a panel inclination that positions the panel perpendicular to sunlight. Let’s look at an example of how to calculate this inclination angle. 8Understanding "worst" as the month in which the ratio between irradiation and demand is worst, typically that case is given in winter when the solar resource is much scarce
Self-consumption installation sizing and design with renewable energies page 35 Example: Optimum inclination for December 21st at 12:00 a.m. One needs to know the location latitude and the sun declination for the given day to find the panel optimum inclination. The sun declination for a given day is computed with Equation 4.2.0.1 [13]. δ= 23.45 ·sin 360 365(dn+ 284)(4.2.1) Where δnis Julian day (δn=[1,2,3,...,365]). December 21st is δn=355, thus the sun declination is δ=-23.45º. An simplified schema of the earth to represent the angles of interest can be seen in the Figure 4.2.1 Figure 4.2.1: Angle schema •Sun declination δ=-23.45º •Latitude φ= 41.38º •φ-δ=64.83º(green arch) •Sun inclination at 12:00 a.m. γ=90-64.83=25.17º •Optimum panel inclination β= 90-γ=64.83º A sun-chart for the given latitude has been generated online from source [14] to find the sun inclination any day of the year at any hour. The chart in Figure 4.2.2 has been used to confirm that the found sun inclination was right. The azimuth is one of the angles that define the sun position. In this chart an azimuth equal to 180ºthe south. In Figure 4.2.3 an schema of the angles related with the sun position are showed.
page 36 Report Figure 4.2.2: Sun-chart. Source [14] Figure 4.2.3: Solar angles. Source [13] This way it has been found that the panel inclination that would maximize in-plane irradiation in the winter solstice is 64.83º. For the summer solstice and the equinoxes these optimum angles are 17.93ºand 41.38ºrespectively. Since we want to maximize the generation throughout all the year, we have to find an inclination that maximizes this energy yield in average. According to source [15] the optimum inclination in Barcelona for this aim is 38º. At this angle, the monthly
Self-consumption installation sizing and design with renewable energies page 37 in-plane irradiation received is displayed at Figure 4.2.4 Figure 4.2.4: In-plane irradiation at 38ºat the selected location. Source [15] The average daily SPH (Solar Peak Hours)9for every month are the ones displayed at Figure 4.2.5. Figure 4.2.5: Daily Average Solar Peak Hours at 38ºper month If we take as an example the month of April whose daily average of SPH is 5.96 hours, this means that the on-plane irradiation (energy kWh/m2) received per day is the same as if the irradiance received was a fixed power of 1 kW/m2for 5.96 hours. Nevertheless, when searching for the required equipment for the facility, the panel support 9If the irradiation received was 1 kW/m2then the SPH are the hours needed for the irradiance (that is to say, energy in kWh/m2[16]) received to be the same as in the reality.
page 38 Report structures found in the market have a fixed inclination of 15ºor 30º. There might exist with customized inclination, but the price increase does not compensate the small increase in energy production. Therefore, a 30ºinclination will be the one to considered even though is not the theoretical optimum. It is noticed that the annual SPH average only decreases in a 0.72%. Figure 4.2.6: Daily Average Solar Peak Hours at 30ºper month The distance between panel lines is an important aspect to prevent shading since a shade in just one part of the module can affect significantly the panel output voltage. The winter solstice is the day for which the sun inclination is lower and therefore shades are the largest. For this day one should ensure that there will be no shading in between 12:00 a.m.±2h. The sun inclination at 10:00 a.m. and 2:00 p.m. in December 21st is approximately γ=20ºand the azimuth angle (considering that 0ºis south) is ψ=±30º. See Figure 4.2.2. The length of these shades has been calculated analytically. In Figure 4.2.7 are displayed both a 3D schema of the panels facing south and a North-South projected schema for the calculation of the shadow in this example. (a) 3D schema of panels facing south (b) Projection to North-South direction Figure 4.2.7: Schema for shadow calculation South panel orientation
Self-consumption installation sizing and design with renewable energies page 39 Example: Minimum distance between panel lines on December 21st at 10:00 a.m.: See Figure 4.2.7 to identify the angles involved. The shadow length is given by the following equation 10: S=x1+x2=a·cos(β) + h tanγ (4.2.2) Where: a: panel height h=a·sin(β) To finally find the minimum distance, one just should project this distance to the North-South direction: D=S·cos(ψ) = x1·cos(ψ) + x2·cos(ψ) = a·cos(ψ)cos(β) + sin(β) tanγ (4.2.3) This is a generic expression to find the shadow length projected in a certain direction. The distance between panel lines is considered to be x2·cos(ψ). The number of panels will be a decision based on: the results from the HOMER software simulations, the length of the chosen panels (which will affect the shadow length and therefore the minimum distance between panels), and the maximum input power supported by the selected inverter. There is a limitation in the number of panels because of the available area. The sizes of the panels that are being considered are around 2000-2015mm of height and around 1000-1015mm of length. For the different combinations that are being considered the minimum distance between panel lines to prevent shadowing are displayed in the Table 4.2.1. The panel sizes that are being considered for these calculations are 2100x1100 mm because these are an approximation of the average maximum dimensions of the panels that have been found. Table 4.2.1: Minimum distance between panel lines (Dec 21st) [mm] Orientation/Layout Horizontal Vertical South (both 10:00 am and 2:00 pm) 1020 1950 Parallel to rooftop (10:00 am) 310 590 Parallel to rooftop (2:00 pm) 1140 2180 The angles and parameters that correspond to each one of these values are displayed in the Table 4.2.2 below. 10This equation has been first deduced on one’s own account and later verified at source [16]
page 46 Report When searching for suitable equipment in the WTG, attention was focused mainly in the following features: rated wind speed, rated power, size and price. It was attempted to find a mini-WTG with rated wind speed around 4 m/s, which is the annual average at the selected location, but it was not found any of the kind. The smallest wind turbines were selected and the lowest rated power for them were around 10 m/s and rated power around 300-400 W. It is noticed that the wind energy installation is most likely not to be feasible. Nevertheless, the firsts simulations will consider the wind energy resource as an input and with its output it will be decided whether to keep considering wind energy or not. In the Table 5.2.1.1 below, the features for the most suitable VAWT and HAWT for this project are displayed. It is noticed that VAWT equipment cost is much higher, as well as having a much lower efficiency. Table 5.2.1.1: Wind Turbine data sheet features. Source [11] Feature Aeolos V Aeolos H Rated Power [W] 300 300 Rated WS [m/s] 10 9.5 Cut in WS [m/s] 2.5 1.8 Efficiency [%] 24.43 85 Generator type Three-phase permanent magnet Three-phase permanent magnet Rotor diameter [m] 1.2 1.7 Rotor swept area [m2] 2.04 2.3 Turbine price [€] 1393 330 Tower (3m) price [€] 395 216 MPPT [€] 213 213 The generator is a variable speed one. The higher the wind speed, the higher the generator speed. The MPPT would ensure that the maximum power is extracted from the wind turbine under the given condition, as well as transform the power into a suitable voltage and frequency for the grid. For the simulations the Aeolos H features will be the ones introduced in the software for its lower cost and higher efficiency. 5.2.2 PV panels The maximum number of panels that will be installed is most likely to be around 10-12 (due to surface availability). Therefore, the panel model to be considered needs to have a Maximum Power Voltage (VMP) such that when considering 10-12 panels in series, the total voltage is suitable with the maximum voltage that the inverters that are being considered can support per MPPT (per string), that is to say, around 500V total output voltage (per string). Also the Maximum Power Current (IMP) has to be suitable with the maximum current that can be supported by the inverters (13A or less). The higher the rated power the better, but of course the price will increase along with it. Since the surface availability is not very large, panels between 400-500W are the ones that have been tracked. Another constraint to be taken into account is the panel height, since the shadows will increase along with it, and a height superior to 120cm would cause shadows and therefore less lines of panels could be installed in the booth top.
Self-consumption installation sizing and design with renewable energies page 47 Taking into account these aspects, after some research in the PV panels market three candidates have been chosen for having the most suitable features. In Table 5.2.2.1 can be found the most relevant characteristics extracted from their data sheets. Table 5.2.2.1: PV panels data sheet features. Source [18] Feature JAM66S30 JAM72S20 ERA450 Rated Power [W] 500 460 450 V(MP)[V] 38.35 42.13 41.5 V(OC)[V] 45.59 50 49.3 I(MP)[A] 13.04 10.92 10.85 I(CC)[A] 13.93 11.45 11.6 Sizes (length x height) [mm] 2093 x 1134 2112 x 1052 2094 x 1038 Efficiency [%] 21.10 20.70 20.70 Temperature coeff of power [%/ºC] -0.35 -0.35 -0.35 Price [€] 205.3 206.8 180.5 Ratio [€/Wp] 0.4106 0.4496 0.4011 The best ratio €/Wpis the one from panel model ERA450, so the first impression is that this one could be the best option. For the two panel layout (horizontal and vertical) the model structures are a bit different. In the Table 5.2.2.2 below a table with the main features is displayed. Table 5.2.2.2: PV panel structures features. Source [18] 72c 20H Type Vertical 2 Horizontal Inclination [º] 30 30 Max. sizes[mm] 2100x1100 2279x1150 Price [€] 127.9 88.62 5.2.3 Inverter for the PV array For the inverter search, the important features to be focused on are: the rated power, the voltage threshold, maximum current supported and price. The brand Growatt has lots of models, which means a great range of maximum power input among which to choose. Furthermore, the maximum supported voltage and input current are suitable with the voltage and current that would yield the PV array if the number of panels was maximum. In Table 5.2.3.1 below the features mentioned are displayed. For installation up to 15kW the connection needs to be to a single-phase line [16]. This is the case of study so the inverter types that has been searched are all single-phase connection type. To size the inverter power usually a relationship factor with the PV array power is used [16] as can be seen in the formula 5.2.1 below: PInverter =PP V array 1.2(5.2.3.1) This is a general factor but most of the inverters data sheets specify a very similar one.
page 48 Report Table 5.2.3.1: Inverter features. Source [18] Feature/Model MIC Growatt 2000 TL-X MIN Growatt 2500 TL-XE MIN Growatt 3000 TL-XE MIN Growatt 4200 TL-XE MIN 3000 TL-XH Max Input Power [W] 2800 3500 4200 5040 6000 Voltage Threshold per MPPT[V] 50-500 80-500 80-550 80-550 70-500 Maximum Input Current per MPPT [A] 13 12.95 12.5 12.5 13.5 Maximum Short-circuit Current per MPPT [A] 16 16 16 16 16.9 Number of MPPT 1 2 2 2 2 Efficiency [%] 97 97.1 97.1 97.5 97.1 Price [€] 476.8 608.1 655 795.21 697.66 Ratio [€/W] 0.1703 0.1737 0.1559 0.1578 0.1163 The inverter model will be chosen depending on how many panels the simulations suggest to install. 5.2.4 Grid Inputs In this section is where one can define the rate schedules and sellback rate. Some research has been made comparing different energy trading companies that offer special rates for neighbour communities with self-consumption installations. The one that was found the more appealing is from the company Naturgy [19]. See Figure 5.2.1 to find the grid rates and their schedules. The surplus compensation modality chosen is the simplified one, in which the surpluses are deducted from the monthly bill. The alternative is to dump the surpluses to the grid in sales basis, in which the energy trading company would have no role. For the chosen modality, the compensation can’t be such that the bill is equal to 0 due to the fixed costs. Hence, it is also not possible to earn money with the compensations, the energy trading company just allows to reduce the bill.
Self-consumption installation sizing and design with renewable energies page 49 (a) Grid rates (b) Rates schedule Figure 5.2.1: Grid Rates 5.3 Simulations outputs The main simulations to be done are the ones that correspond to the four panel configurations to be considered (see Figure 4.2.8). For each one of them some input parameters are different (for the PV arrays) while for the rest of equipment parameters are the same (i.e. for the wind turbine).
page 50 Report As methodology, in each case a first simulation is done doing a sweep in the installed power for both wind turbine and PV array to see and approximation of around which number of wind turbines or panels is the optimum. In all cases, the software returns as the optimum the maximum installed power in the sweep because it takes into account the sell-back ratio and therefore it seems that the more PV panels the better. In spite of that, it was not considered to search for more available space than the one that was being considered because even if the software identifies this sell-back rate as a benefit, it is not 100% certain that the energy trading companies are going to maintain it in the long term. It is most likely to be at least reduced in the next years though it can’t be estimated how much. Consequently, even if the software suggest that the installed power should be greater, it will be limited to the available space. 5.3.1 General comparison of results Let us review first the parameters that are introduced to the software differently in each configuration. The Figures from 4.2.8 are displayed here again for convenience. Figure 5.3.1.1: South & Horizontal configuration Table 5.3.1.1: South & Horizontal HOMER distinguishing parameters Parameter Value Details Capital[€] 269 Both panel and horizontal structure Replacement [€] 181 Panel ERA 450 Azimuth [º] 0 Facing south Sizes to consider [kW] 0; 1; 3.15 0.45kW per panel and 7 panels equal 3.15kW
Self-consumption installation sizing and design with renewable energies page 51 Figure 5.3.1.2: South & Vertical configuration Table 5.3.1.2: South & Vertical HOMER distinguishing parameters Parameter Value Details Capital[€] 308.4 Both panel and vertical structure Replacement [€] 181 Panel ERA 450 Azimuth [º] 0 Facing south Sizes to consider [kW] 0; 1; 3.6 0.45kW per panel and 8 panels equal 3.6kW
page 52 Report Figure 5.3.1.3: South-West & Horizontal configuration Table 5.3.1.3: South-West & Horizontal HOMER distinguishing parameters Parameter Value Details Capital[€] 269 Both panel and horizontal structure Replacement [€] 181 Panel ERA 450 Azimuth [º] 45 Facing south Sizes to consider [kW] 0; 1; 4.5 0.45kW per panel and 10 panels equal 4.5kW
Self-consumption installation sizing and design with renewable energies page 53 Figure 5.3.1.4: South-West & Vertical configuration Table 5.3.1.4: South-West & Vertical HOMER distinguishing parameters Parameter Value Details Capital[€] 308 Both panel and horizontal structure Replacement [€] 181 Panel ERA 450 Azimuth [º] 45 Facing south Sizes to consider [kW] 0; 1; 5.4 0.45kW per panel and 12 panels equal 5.4kW If we consider the results from all four simulations and we order them by the Net Present Cost (NPC) 12 we obtain the Table 5.3.1.5. Where SH, SV, SWH, SWV are South Horizontal, South Vertical, South-West Horizontal and South-West Vertical respectively. 12The NCP of a system is the present value of all the costs that incurs over its lifetime minus the present value of all the revenue that it earns over its lifetime [12].
page 54 Report Table 5.3.1.5: Simulations general results Config PV [kW] AH300 Converter [kW] Initial Capital [€] Operating Cost [€/year] Total NPC COE [€/kWh] SWV 5.4 - 6.00 4,394 -68 3,427 0.038 SWV 5.4 1 6.00 5,153 -80 4,020 0.045 SWH 4.5 - 4.20 3,251 107 4,772 0.053 SWH 4.5 1 4.20 4,0101 95 5,364 0.059 SV 3.6 - 4.20 3,025 229 6,281 0.070 SV 3.6 1 4.20 3,784 217 6,870 0.076 SH 3.15 - 2.80 2,3600 326 6,997 0.078 SH 3.15 1 2.80 3,119 314 7,585 0.084 SH - - - 0 1,148 16,313 0.181 SV - - - 0 1,148 16,313 0.181 SWH - - - 0 1,148 16,313 0.181 SWV - - - 0 1,148 16,313 0.181 SH - 1 - 759 1,134 16,879 0.187 SV - 1 - 759 1,134 16,879 0.187 SWH - 1 - 759 1,134 16,879 0.187 SWV - 1 - 759 1,134 16,879 0.187 The configuration with the lowest NPC is the South-West and Vertical, with no wind turbine. The second one is the same configuration but including a wind turbine, which was actually not an expected result. Yet, when examining the results of the WT energy production one discovers that the mean output power throughout the year is 0.01 kW while the rated power is 0.3 kW. It does not seem realistic that this combination is the optimum one. The software points it out this way because according to the wind turbine power curve and the wind speed throughout the year some energy is produced, but the wind speed is too low to be considered a reliable energy source in other years. For this reason, the results including wind turbine but with such low mean output power are disregarded. If the mean output power was a higher one these combinations would be considered. One aspect to point out is that South-West facing configurations are better than the South facing ones because, even if the orientation is not the theoretical optimum (when being in the North Pole the orientation that maximizes the irradiation is south), the possibility of being able to introduce more panels compensates the slight decrease in energy yield due to the lower irradiation. Another comment on the general results is that the results without any equipment installation (all the energy is purchased from the grid) is categorized as a better option than installing only one wind turbine, due to the fact that the earnings the wind turbine would generate over the project life would not achieve a total compensation of the initial capital invested. Between the two best options (SWV and SWH) one notices that the SWV has a negative Operating Cost, that is to say, that the neighbour community would be earning money each year from selling energy to the grid. As previously mentioned in 5.2.4, this is not a feasible situation. In consequence, the chosen configuration has been SWH (without wind turbine) and a further analysis of the result is carried out in section 6.
Self-consumption installation sizing and design with renewable energies page 55 6 Facility performance Let us review which are the components of the selected location. On one hand the facility would consist of 10 PV panels of model ERA 450 which results in an installed power of 4.5 kW. See Figure 5.3.1.3 for the panels set up. The panel structures to be used are 10 modules of the Horizontal 20H model (see the datasheets in the Annexes 8). Thesoftwareindicates that thesuitable converterwould be theoneof 4.2 kW, which corresponds to MIN Growatt 3000 TL-XE. This model is equipped with two independent MPPT. This will be useful because an array of 10 panels would generate a voltage in the inverter input of almost 493 V, which would be supported by the inverter but is much greater than the nominal (360 V). Hence, the array will be divided in two groups and connected to the inverter in two strings independent from each other. This inverter allows even to connect arrays of panels of different electric characteristics or orientations to each MPPT [18]. Thus, the ground PV array (6 panels) will be connected to one MPPT and the one from the booth top (4 panels) to the other one. The results that the software has provided will be analysed both in energy and economic terms. 6.1 Energy yield First let us have a look at the monthly average data. It has been analysed the source from which the energy consume would come from: PV or grid. In Figure 6.1.1 one can observe how much energy the PV panels are generating throughout the year and how much energy is consumed from the grid. (a) Monthly average energy production (b) Annual energy production 11,018 kWh Figure 6.1.1: Monthly average energy production: PV and grid
page 62 Report 7 Budget The costs associated with the equipment used in the project as well as the human resources costs are displayed in Table 7.1. Table 7.1: Project Costs Concept Unit Cost Quantity Total Equipment Personal Computer 600 €1 600 € Solid Works student licence 90 €/year [20] 1 90 € HOMER free version licence 0 €1 0 € Human Resources Engineering student agreement 8€/h 450 h 3600 € Supervision 30 €/h 30 h 900 € Total 5190 €
Self-consumption installation sizing and design with renewable energies page 63 8 Environmental study, social and gender equality impact The environmental impact of the project aims to be positive since its objectives are aligned with the transition to renewable energies and reduce relyment on fuel fossils. The life duration of most of the equipment chosen in the project is above 15 years so this reduces the environmental impact of the materials used. The PV panels are made mainly of glass, aluminium, silicon and plastics. These materials can be relatively easily recovered and recycled. Inverters include various metals as copper, steel, aluminium among others. In the inverters the materials are a bit harder to recover but these metals can be recycled with certain ease. Regarding the social and gender equality impact of the project, it can be mentioned that the fact that both the author and the tutor are women, it is being contributed to an increased presence of women in engineering fields. According to the Spanish National Statistics Institute [21], during 2020 the rate of men and women between 20-29 years old graduated in fields of science, mathematics, computer science, engineering, industry or construction are the ones displayed in Figure 8.1 Figure 8.1: Rate of STEM graduates in Europe and Spain. Source [21] The way to equal this rates is to enhance that women not only participate in engineering projects but also arrive to influence positions, as well as boosting young women to study STEM degrees that have been historically seen as manly fields.
page 64 Report Conclusions The main aim and motivation of the project was to contribute to the energy decarbonization, to achieve both a cleaner and cheaper energy source and to help make cities rely more on sustainable energies rather than fossil fuels. Once done the resource study along with the demand analysis and the design and sizing of the case of study, the results lead us to some conclusions aligned with the objectives of the project and its context. The renewable sources considered in the project were mini-wind and PV energy. Regarding conventional mini-wind energy the conclusion is that in the selected location is not profitable at the moment because of the mismatch between the annual average wind speed and the rated wind speed for the smallest wind turbines found. Nevertheless, the Vortex Bladeless technology seems very promising for where the conventional mini wind energy fails, and that is why it has been studied and mentioned along this project. Also placing a wind turbine tower of three meters in the rooftop of the selected location would require a previous structural study that was not in the scope of the project. It is observed that the technology available for PV energy allows achieve very competitive facilities both in economic terms and energy yield. The city of the selected location (Barcelona) has a great potential for PV panel installation since a great deal of the buildings have suitable surface for it available in the rooftop. Therefore the blocking point for it (at least in the selected location and probably in many other neighbour communities) is not the technology but the legislative or bureaucratic process. In the selected location this project has been proposed to the neighbour community more than once and the obstacle is that since there are three blocks with 6 different stairwell in each, there is no agreement in whether each stairwell can decide on their own, if it should be decision taken by each building block or if it should be decided by the property manager and installed the same way for the three blocks. From the outside does nos seem a big blocking point but reality is that this initiative has not been carried out because of this point. PV energy has a characteristic curve of production. During the central hours of the day there is a higher energy production and most of the times is more than enough to cover the energy demand and even sell the surplus to the grid or store it in the batteries if the facility is equipped with them. With PV energy, even if the annual PV production is greater than the annual electric demand, the challenge is not the amount of energy produced but how and when it is demanded and consumed. This mismatch between the production and consumption pattern makes PV energy have a lower performance and need to combine with other sources to supply the system without interruptions. One solution is to add batteries to the system but this increases a great deal the initial capital, the life duration of batteries is limited and the materials they are made of have quite a negative environmental impact. Nevertheless, technologies for batteries are continuously improving for higher life duration and some alternative materials with less negative impact are being tried. Another alternative is trying to change the consumption pattern: adapt the demand curve to the production curve. While this can be difficult for particulars, some industries are already starting to make their demand curve more flexible by adapting their industry activity to the production curve. The industries that can include this changes in their daily activity have a great advantage now that the energy cost is increasing as never before.
Self-consumption installation sizing and design with renewable energies page 65 From the above, for really taking leverage of PV energy and renewable energies in general, the patterns of consumption need to re-adapt to the current situation. On the other hand, the option of selling to the grid when there is surplus, as it is proposed in this project, does not seem a bad option in this case and for most cases when the facility is for particulars and not industries or companies. As long as the surplus is not as big as to consider that the facility is oversized. The overall conclusion is that the installations of renewable sources such as PV panels in the cities can be very adequate when the aim is reduce the annual bill and rely more on sustainable energy. But to be fully off-grid or adapt completely to the production curve turns into a difficult challenge in which one should consider these options among others: add batteries to the system, change the consumption patterns and/or add other renewable sources that produce when the PV panels do not.
Self-consumption installation sizing and design with renewable energies page 67 Bibliography [1] Redeia, Red eléctrica, 2021. [Online]. Available: https://www.sistemaelectrico-ree. es/sites/default/files/2022-08/InformeEnergiaRenovable2021_Resumen.pdf. [2] H.-J. Wagner and J. Mathur, Introduction to Wind Energy Systems, 3rd ed. Springer International Publishing, 2018. [Online]. Available: http://www.springer.com/series/8059. [3] A. Ramos, Energy and Society, Wind Power. Technical University of Madrid, 2022. [4] N. T. Burton and D. Jenkins, Wind Energy Handbook. 2011. [5] R. Castro, Electricity Production from Renewables. Springer International Publishing, 2022. doi:10.1007/978-3-030-82416-7. [6] M. Islam, D. S. Ting, and A. Fartaj, Aerodynamic models for Darrieus-type straight-bladed vertical axis wind turbines. May 2008, vol. 12, pp. 1087–1109. doi:10.1016/j.rser.2006. 10.023. [7] D. Jesús and Y. Villarreal, “Viv resonant wind generators,” [Online]. Available: www . vortexbladeless.com. [8] G. Maps, Google maps location, 2022. [Online]. Available: https://www.google.es/maps/ @41.3803723,2.1450085,294m/data=!3m1!1e3?ucbcb=1. [9] Nasa, Power data access viewer, 2022. [Online]. Available: https://power.larc.nasa. gov/data-access-viewer. [10] C.N.deEnergíasRenovables(CENER),Iberian wind map,2022.[Online].Available:https: / / www . mapaeolicoiberico . com / map ; latitude = 41 . 37980 ; longitude = 2 . 14471 ; altura=50;dato=micro. [11] Aeolos,Aeolos wind turbines ltd,2022.[Online].Available:https://www.windturbinestar. com/. [12] Homer (hybrid optimization of multiple energy resources), 2022. [13] A. Ramos, Técnicas apropiadas en la dotación de servicios básicos. Technical University of Madrid, 2022. [14] U. of Oregon, Solar radiation monitoring laboratory, 2022. [Online]. Available: http : / / solardat.uoregon.edu/SunChartProgram.html. [15] E.Comission,Photovoltaic geographical information system,2022.[Online].Available:https: //re.jrc.ec.europa.eu/pvg_tools/en/. [16] I.I.C. d’EnergiaGeneralitatdeCatalunya,Energia solar fotovoltaica. Col.lecció Quadern Pràctic Número 4. 2020. [17] M. H. A. R. J. F. I. Z. C. N. Markides, “Energy conversion and management,” 2018. [Online]. Available: https://www.sciencedirect.com/journal/energy-conversion-and- management. [18] A. E. S. SLU, Auto solar, 2023. [Online]. Available: https://autosolar.es/. [19] Naturgy, Tarifa solar naturgy, 2023. [Online].Available:https://www.naturgy.es/hogar/ solar/tarifa_solar#precios-y-condiciones. [20] S. Works, Solidworks student edition, 2023. [Online]. Available: https://www.solidworks. com/product/students. [21] I. N. d. E. (INE), Graduates rate for stem degrees, 2020. [Online]. Available: https://www. ine.es/jaxi/Datos.htm?path=/t00/mujeres_hombres/tablas_2/&file=C1G3.px# !tabs-tabla.
page 68 Report Annex PV panel datasheet PV panel structure datasheet Inverter datasheet
ESPHSC Monocrystalline Half-Cut Solar Module KEY FEATURES Wp LOW LIGHT MBB Half-Cut Solar Cell: Light-weight design Higher Power Output Low-light Performance: 144 cells (6X24); 9 busbar solar cell. Light-weight design using transparent backsheet for easy installation and low BOS cost. Advanced glass and surface texturing allow for excellent performance in low-light environments. 166mm SERIES, 72-CELL HALF-CUT SERIES ELECTRICAL PERFORMANCE CURRENT-VOLTAGE CURVES: MODULE DIAGRAM: 1038mm 2094mm 1038mm 2094mm 35mm TPT in white 144(6x24) / monocrystalline silicon 166 +12 25 WATTS POSITIVE TOLERANCE YEARS PRODUCT WARRANTY YEARS LINEAR POWER WARRANTY ERA SOLAR and the ERA SOLAR logo are trademarks or registered trademarks of ERA SOLAR Corporation. 2019 October IN METRO www.erasolar.com.cn Zhejiang ERA Solar Technology Co., Ltd. 20A 1000/1500V/DC ESPHSC Container Size Units/Pallet (PCS) Weight/Pallet (KG) Units/Container (PCS) Pallet Measurment (mm) 20GP 40HQ 58(31+27) 31 35 1422 735 855 290 726 2150x1130x2220 2150x1130x1170 2150x1130x1345 PACKING Module type: Maximum Power(Wp) Open circuit Voltage(Voc) Maximum Power Voltage(Vm) Maximum Power Current(Im) Maximum Series Fuse Watts positive tolerance Number of Diode Standard Test Conditions Maximum System Voltage Normal Operating Cell Temperature Load Capacity for the cover of the module (glass) Load Capacity for the front & back of the module 2094x1038x35mm 24kg low-iron tempered glass / 3.2mm aluminum hollow-chamber frame on each side anodized aluminum alloy / silver ≥IP68 4mm², 300mm in length,length can be customized Class A Class II Class C MECHANICAL CHARACTERISTICS Front cover (material / thickness) Backsheet (color) Cell (quantity / material / dimensions) Frame (material / color) Junction box (protection degree) Cables & Plug connectors Module Dimensions (L / W / H) Module Weight Application class Electrical protection class Fire safety class Short circuit Current(Isc) 0~+3% 3 -40°C...+85°C 5400Pa(IEC61215)(snow) 2400Pa(IEC61215)(wind) ESPHSC Module type: ELECTRICAL PERFORMANCE (NOCT) Maximum Power(Wp) Open circuit Voltage(Voc) Maximum Power Voltage(Vm) Maximum Power Current(Im) Short circuit Current(Isc) +0.049%/°C -0.271%/°C -0.352%/°C 1000W/M²,25°C,AM1.5 450M 450W 49.30V 11.60A 41.50V 10.85A 20.70% / 455M 344W 46.55V 9.27A 39.40V 8.74A / // /430M 325W 45.55V 8.99A 38.40V 8.46A 435M 329W 44.75V 9.06A 38.60V 8.51A 445M 336.5W 46.15V 9.17A 39.00V 8.62A 440M 332.5W 45.95V 9.11A 38.80V 8.57A 450M 340W 46.35V 9.22A 39.20V 8.68A /24//23/
Reservado el derecho a efectuar modificaciones · Las ilustraciones de productos son a modo de ejemplo y pueden diferir del original. 20H Ficha técnica Herramientas necesarias: Seguridad: 2279x1150 Par de apriete: Tornillo Presor Tornillo M8 Hexagonal Tornillo M10 Hexagonal Tornillo M6.3 Hexagonal 7 Nm 20 Nm 40 Nm 10 Nm ·Soporte inclinado para cubierta metálica o subestructura. ·Anclaje a chapa. ·Soporte premontado. ·Sin perfil guía. ·Disposición de los módulos: Horizontal. ·Valido para espesores de módulos de 30 hasta 45 mm. ·Tornillería de anclaje no incluida. ·Kits unitarios de 1 módulo. ·Inclinación estándar 15º y 30º Viento: Hasta 150 Km/h (Ver documento de velocidades del viento) Materiales: Perfilería de aluminio EN AW 6005A T6 Tornillería de acero inoxidable A2-70 Comprobar el buen estado y la capacidad portante de la cubierta antes de cualquier instalación. Comprobar la impermeabilidad de la fijación una vez colocada. Para módulos de hasta 2279x1150 - Sistema Kit Soporte inclinado cerrado para cubierta metálica, 1 módulo. Apriete de las uniones y anclaje al suelo mediante tornillo de hasta M10 Triángulo plegado R1-02/21 100% Reciclable Anclaje a correas Tornillería incluida EPDM Carga de nieve: 40 kg/m²
Reservado el derecho a efectuar modificaciones · Las ilustraciones de productos son a modo de ejemplo y pueden diferir del original. 20H Velocidades de viento R1-04/21 Soporte inclinado cerrado para cubierta plana 1 módulo. Para cumplir con las velocidades máximas admisibles de viento especificadas en la tabla 1, se deberán respetar todas las instrucciones indicadas en los planos de montaje. Se debe comprobar que los puntos de anclaje para los módulos son compatibles con las especificaciones del fabricante. Cuadro de velocidades máx. admisibles de viento Tamaño del módulo 1nº de módulos 2000x1000 150 Velocidad de viento km/h 2279x1150 150 Tabla 1 - Velocidades máximas de viento admisibles. Flujo viento - En estructura inclinada. - Cargas de viento: Según túnel del viento en modelo computacional CFD - Cálculo estructural: Modelo computacional comprobado mediante EUROCÓDIGO 9 "PROYECTO ESTRUCTURAS DE ALUMINIO" - Para garantizar la resistencia a la velocidad máxima de diseño se deberán utilizar anclajes adecuados y utilizar el lastre indicado por el fabricante para cada situación. Sistema kit