scieee AI-readable full text Open interactive document viewer

Respiratory sinus arrhythmia quantified with linear and non-linear techniques to classify dilated and ischemic cardiomyopathy

Giraldo Giraldo, Beatriz,Pericas, Maria Francisca,Schroeder, Rico,Voss, Andreas

Full text

 Abstract— In congestive heart failure (CHF), dilated cardiomyopathy (DCM) and ischemic cardiomyopathy (ICM) are two highly related pathologies that are not fully characterized. The aim of this study is to assess respiratory sinus arrhythmia (RSA) index of the parasympathetic system, in order to discriminate between both pathologies, DCM and ICM. For this, ECG-signals of 49 subjects (12 DCM patients, 21 ICM patients, 6 ICM patients with diabetes mellitus (DM) type II and 10 control subjects) from the database HERIS II and of 173 subjects (50 DCM, 50 ICM, 15 DCM with DM type II, 15 ICM with DM type II and 47 control subjects) from the database MUSIC2 were analyzed. The RSA was quantified using linear and non-linear analysis methods (fractal dimension and entropy). The results showed a significant difference between ICM and DCM subjects (p=0.013) with a sensitivity of 83% and specificity of 90%. Decreasing RSA values were present in CHF patients, especially in ICM patients, in comparison with healthy subjects. Alterations in the parasympathetic system due to DM were also identified. I. INTRODUCTION Congestive heart failure (CHF) is a growing epidemic in Western countries with increasing incidence and prevalence. Dilated cardiomyopathy (DCM) has an incidence near to 20/10.000 new cases per annum and is responsible for almost 10.000 deaths every year in the United States [1,2]. Ischemic Cardiomyopathy (ICM) is the number one cause of death in men and the third most frequent cause of death in women. In presence of diabetes mellitus (DM), cardiovascular morbidity and mortality are increased in CHF patients compared with CHF patients without DM [3,4]. * This work was supported in part by the Secretariat of Universities and Research of the Department of Economy and Knowledge of the Government of Catalonia (Consolidated research group GRC 2014 SGR 1569), by CERCA Programme / Generalitat de Catalunya, by the Spanish Ministry of Economy and Competitiveness through project DPI2015- 68820-R (MINECO/FEDER), by grants from the Federal Ministry for Economic Affairs and Energy (BMWI) KF 2447308KJ4 and KF 2447309KJ4. B.F. Giraldo is with Automatic Control Dept. (ESAII), EEBE, Universitat Politècnica de Catalunya (UPC), CIBER de Bioengenieria, Biomateriales y Nanomedicina (CIBER-BBN) and Institute for Bioengineering of Catalonia (IBEC), The Barcelona Institute of Science and Technology, Av. Eduard Maristany, 16. 08019, Barcelona, Spain. ([email protected]). M.F. Pericàs is with Automatic Control Dept. (ESAII), EEBE, Universitat Politècnica de Catalunya (UPC). R. Schröeder and A. Voss are with the Ernst-Abbe-Hochschule Jena, University of Applied Sciences Jena, Institute of Innovative Health Technologies, Carl-Zeiss- Promenade 2, 07745 Jena, Germany (corresponding author to provide phone: 49-3641-205-625; fax: 49-3641- 205-626; e-mail: [email protected], [email protected]). In recent years, a higher association between CHF, DM and cardiac vagal tone has been found [5]. In addition, an increase in cardiac mortality due to an autonomic dysfunction related to cardiomyopathies was reported. Therefore, the cardiac vagal tone index, known as respiratory sinus arrhythmia (RSA), has been proposed as a parameter able to discriminate within CHF pathologies and risk levels [6]. RSA is a rhythmic fluctuation in the heart periods in the respiratory frequency, characterized by a shortening and lengthening of heart periods in phase relationship with inspiration and expirations. It is also a typical index of vagal control of the heart (parasympathetic effect) [6]. RSA can be quantified using the spectral analysis of the heart rate variability (HRV), where the high frequency component is related to the parasympathetic activity, and the low frequency is mainly related to sympathetic activity [7,8]. In this study, the main objective is the characterization of the vagal tone index using linear techniques based on the estimation of the mean and the standard deviation of the RSA and non-linear techniques such as fractal analysis by means of Higuchi Dimension, and Shannon Entropy technique. Additionally, it will be analyzed whether indices quantifying the RSA are suitable to distinguish between DCM and ICM pathologies. II. MATERIAL AND METHODS A. Datasets In this study, two datasets (HERISII and MUSIC2) with CHF patients suffering from dilated cardiomyopathy (DCM) or ischemic cardiomyopathy (ICM), with and without diabetes mellitus (DM) type II were studied. Additionally, 57 control subjects were investigated as a reference group. HERISII database contains high resolution ECG signals of cardiomyopathy patients recorded at the Santa Creu i Sant Pau Hospital in Barcelona, Spain. 30-minute resting (quite room, supine position, daytime) ECG recordings were acquired using a sampling frequency of 1600 Hz [9]. From the database, 49 age-matched male subjects (12 DCM patients, 22 ICM patients, 6 ICM patients with DM, and 10 control subjects), who fulfill the inclusion criteria, were selected for the RSA analyses. Due to the low number of enrolled women in the HERISII database, they were excluded from this study. Table I shows the summary of this database. MUSIC2 database (Sudden Death in Heart Failure) contains 24-hour Holter ECGs recorded in several hospitals in Spain (200 Hz sampling frequency) [10]. From this database, an amount of 173 age-matched subjects (age was comparable to the chosen HERIS subjects) were studied (50 Respiratory Sinus Arrhythmia Quantified with Linear and Non- Linear Techniques to Classify Dilated and Ischemic Cardiomyopathy * Beatriz F. Giraldo, Senior Member, IEEE; María Francisca Pericàs, Rico Schröeder and Andreas Voss, Senior Member, IEEE DCM, 50 ICM, 15 ICM plus DM type II, 15 DCM plus DM type II and 47 control subjects). Table II presents the summary of this database. TABLE I. HERIS II DATABASE SUMMARY DCM ICM ICM+DM N 12 21 6 Age (years) 62,22±10,12 64,23± 9,60 64,43± 9,59 BMI (kg/m2) 28,10± 4,97 27,97± 4,99 27,95± 4,65 LVDD (mm) 61,40± 6,84 61,40± 6,76 61,30± 7,12 TABLE II. MUSIC2 DATABASE SUMMARY DCM ICM DCM+DM ICM+DM N 50 50 15 15 Age (years) 59,8±9,7 60,2±9,4 66,4± 10,2 66,1± 8,1 BMI (kg/m2) 27,6±4,8 28,5±4,5 29,0±3,9 30,2±5,7 LVDD (mm) 66,4±10,2 61,2±7,6 65,4±7,1 61,7±4,4 Female N 20 20 5 5 Age (years) 60,1±9,1 59,5±10,2 70,8±4,8 70,6±4,8 BMI (kg/m2) 26,0±3,2 27,9±4,0 28,4±3,3 30,6±6,4 LVDD (mm) 63,7±9,1 60,0±6,2 71,4±8,0 63,2±3,8 Male N 30 30 10 10 Age (years) 60,7±9,0 61,8±8,7 61,9±11,4 61,6±11,4 BMI (kg/m2) 28,6±5,3 28,9±4,7 29,3±4,1 30,1±5,3 LVDD (mm) 68,1±10,4 62,0±8,4 62,4±5,1 61,0±4,9 B. Estimation of Respiratory Sinus Arrhythmia From each ECG record, a time series consisting on successive beat-to-beat (RR) intervals, the so-called tachogram, was automatically extracted using in-house software, based on threshold-based algorithms. Using an adaptive filtering algorithm, ventricular premature beats and artefacts were automatically detected and replaced by interpolated “normal” beats. After this, each tachogram was manually sighted for correctness in relation to the original ECG. Tachograms with ectopic beats and artefacts whose percentage was higher than 5% related to the total number of heartbeats have already been excluded in the run-up to this study. Due to different signal durations in both databases (HERIS: 30-min tachograms, MUSIC2: 24-hour tachograms), an in-house software algorithm searching for and saving the 30-min most stationary phase within each tachogram, which come closest to the tachograms extracted from the resting ECG recordings in HERIS, was applied on the MUSIC2 tachograms. Afterwards, on basis of the preprocessed 30-min tachograms several RSA indices were estimated.  RSA extraction of the spontaneous respiratory band To get equidistant time series, the tachograms were linear interpolated using 2 Hz as sampling frequency. After this, the tachograms were detrended to remove periodic and aperiodic cardiac variations unrelated to respiration from the tachograms. A moving polynomial filter (MPF) of 21 points and order 3 was used to filter the signals, obtaining a template [11]. This template was extracted from the original signal to obtain a mean-zero residual series. This residual series was then, filtered by Chebychev Type II pass-band filter using respiratory band frequencies (0.12 – 0.4 Hz). Finally, the signal was analyzed considering segments of 30 seconds without overlapping [12].  RSA estimation by Porges equation To estimate the RSAML (RSA mean-log) index the average of each 30-s segment was performed, to minimize the impact of any distortion. The RSA value represents the vagal tone which affects the regulation of the heart and it is modulated by the respiration [13]. Then, the natural logarithm was determined to reduce distribution disorder. The RSALM (RSA log-mean) index was inversing the process, applying in first term the logarithm transforms and then estimating the average for each 30-s segment, given by 𝑅𝑆𝐴𝐿𝑀 = log(𝑚𝑒𝑎𝑛 (𝑅𝑅𝑒𝑝𝑜𝑐ℎ 2)) (1) According to Porges [13], RSApsd was estimated using spectral analysis. The sum of the variances associated with the frequency band of spontaneous respiratory was desired. This sum was calculated with spectral analysis by summing the spectral densities associated.  Non-linear estimators The Higuchi Dimension (HD) is able to estimate the fractal dimension from a given time series using the parameter D, which allows the classification of the series according to their fractal characteristics. In severe cardiovascular events, like arrhythmias or heart attacks, a reduction in the fractal complexity results in a good predictor of mortality. The Higuchi algorithm follows the steps [14,15]: The original time series is defined by X(1), X(2), X(3),…, X(N) , (2) new time series are constructed by 𝑋𝑘 𝑚, being k the interval time (m = 1,2,, k) and m the initial time. [•] represents the Gauss notation. 𝑋𝑘 𝑚;𝑋(𝑚),𝑋(𝑚+𝑘),𝑋(𝑚+2𝑘),⋯,𝑋(𝑚+ 𝑁−𝑚 𝑘 𝑘) (3) For each new time series is estimate the length of the curve by 𝐿𝑚(𝑘)=1 𝑘 (∑(𝑋(𝑚+𝑖𝑘)−𝑋(𝑚+(𝑖−1)𝑘)) [𝑁−𝑚 𝑘] 𝑖=1 )( 𝑁−1 [𝑁−𝑚 𝑘]𝑘 ) (4) where 𝑁−1 [𝑁−𝑚 𝑘]𝑘 is a normalization factor. Higuchi method takes the average of L(k) considering the follow power law 𝐿(𝑘) ∞ 𝑘−𝐷 (5) Finally, L(k) is plotted against 1/k (double logarithmic scale), with k = 1, 2, , Kmax. Kmax is a parameter to optimize. The fractal dimension is defined as the slope of straight line in the plot. HD is estimated for each 30-s segment of signal [17]. Shannon entropy (SE) is extracted considering the probability of occurrence of an event, describe the level of disorder energy of the system. According to literature, systems that describe diseases present lowest values of entropy indicating a reduction of the complexity activity, in comparison with healthy systems. The probability is calculated trough 𝑃(𝑋)= ℎ𝑖𝑠𝑡𝑜𝑔𝑟𝑎𝑚(𝑋,𝑁𝑏𝑖𝑛𝑠) 𝑁 (6) where X is the values of the vector with length N, Nbins is the number of bins estimated by Sturges criteria [18] defined by 𝑁𝑏𝑖𝑛𝑠=1+3.32∗log(𝑋). (7) Finally, SE is calculated by (with 6 as number of bins) 𝑆𝐸(𝑋)= ∑𝑝(𝑥𝑖) log𝑝(𝑥𝑖) 𝑥𝑖 ∈ ∅ (8) where X represents the random variable with set of values ∅ and probability function p (xi ). Differences between groups are tested by the Mann–Whitney U test and a p-value < 0.05 was considered statistically significant. The quality of the results is analyzed using ROC curve (receiver operator characteristic), in terms of accuracy (Acc), sensitivity (Sn) and Specificity (Sp). III. RESULTS Figure 1 shows the different RSA indices extracted from a patient. Figure 2 presents HD and SE from the same patient. Figure 1. RSA extracted from a patient whit the Porges Algorithm: Upper subplot) RSAML; Middle Subplot) RSALM; Lower subplot) RSApsd RSAML presented statistical significance difference when comparing DCM vs ICM in HERISII database (p = 0.013). This significance was correlated with the one obtained in MUSIC2 comparing these group in men (p = 0.048). Moreover, MUSIC2 presented significance (p = 0.04) also using RSALM. These significances could be understood as the presence of a different influence of the pathology in the RSA value in men. Using ROC discriminant analysis AUC (area under the curve) =84.4 % with a Sn=83.3% and Sp=90% were obtained in HERISII when DCM-ICM were compared. Figure 2. HD (upper) and SE (lower) of each RRepoch from the PH001 (DCM) The presence of DM in the pathologies (DCM and ICM) resulted in a higher significant difference when both CHF pathologies were compared using RSAML (p = 0.009) in MUSIC2. RSALM and RSApsd showed also a higher significance (p = 0.01, p = 0.021, respectively). Non-linear indexes were useful to discriminate illness patients from healthy subjects. Using HERIS II, significance of 0.006 have been found when matching ICM vs healthy subjects using HD index (Figure 3). It was also noticeable the decrease in the RSA values (RSAML, RSALM and RSApsd) comparing patients with healthy ones. MUSIC2 presented better results comparing DCM vs Healthy and ICM vs Healthy (Figure 4). Figure 3. Comparison of HD in HERIS II between Groups. *p<0.05, **p<0.01 Figure 4. Box Plot HD in the different groups in MUSIC2 mixed group. **p<0.05, ***p<0.1e-10 Matching DCM vs healthy it was obtained significance in both non-lineal indices (HD p = 5.41e-15, SE p=4.40e-05), as well as, matching ICM vs Healthy (HD p=2.94e-14, SE p=4.82e-05). Table III present the results obtained with the best indices. TABLE III. AREA UNDER THE CURVE (AUC), SENSITIVITY (SN) AND SPECIFICITY (SP), AND P-VALUE OBTAINED WITH THE BEST PARAMETERS FOR EACH CLASSIFICATION Index p-value AUC Sn Sp DCM vs ICM RSAML 0.013 86.4 86.3 90.0 DCMDM vs ICMDM RSAML 0.009 77.8 66.7 80.0 DCM vs Healthy HD, SE 1.12e-09 86.6 88.0 85.1 ICM vs Healthy HD, SE 3.64e-10 89.7 92.0 87.2 DCMDM vs Healthy HD, SE 2.50e-03 86.7 86.7 86.7 ICMDM vs Healthy HD, SE 1.57e-04 96.7 100.0 93.3 IV. DISCUSSION In some case, decreased RSA values were present in CHF patients compared with healthy subjects. This decrease was higher in patients suffering from ICM than in DCM patients. The suggested main event that differs between ICM and DCM was the activation of the myocyte apoptosis due to ischemia. While a myocyte necrosis because of the sustained reduction in the coronary blood flow is caused by an ischemic; in DCM, there is a collagen accumulation and a fibrosis in the no infracted myocardium that is remodeling the ventricle but not destroying it. Furthermore, greater levels of plasma noradrenaline have been reported comparing ICM against DCM, suggesting that peripheral sympathetic activation may be different and thus parasympathetic activation. Consequently, ICM seemed to present a higher risk in terms of parasympathetic dysfunction. RSA values showed a decrease in presence of diabetes; however, no statistical significance was found between DCM with and without DM. Even in ICM patients, whose RSA decrease in presence of DM was higher, did not present significance. DM type II is associated with a heightened sympathetic tone and a decreased vagal tone. V. CONCLUSION RSA indices were used to estimate the parasympathetic dysfunction, by the vagal tone, in patients with DCM or ICM. This index demonstrated to be useful in the discrimination between pathologies and to asses a risk increase. ICM patients seemed to show a greater decrease in RSA values. The presence of diabetes mellitus type II helped to discriminate between groups and also seemed to be a risk factor in terms of autonomic dysfunction. Non-linear techniques assessed by HD and SE showed to be useful to discriminate between patients and healthy subjects when they were studied on the RSA information from the tachogram. However, further studies are necessary to refute these conclusions. ACKNOWLEDGMENT We gratefully acknowledge the cooperation from the Spanish hospitals’ cardiological departments participating in the MUSIC [10] and the HERISII [9] studies. REFERENCES [1] A. Voss, R. Schroeder, S. Truebner, M. Goernig, H. R. Figulla, and A. Schirdewan, "Comparison of nonlinear methods symbolic dynamics, detrended fluctuation, and Poincare plot analysis in risk stratification in patients with dilated cardiomyopathy," Chaos, vol. 17, p. 015120, Mar 2007. [2] S. B. Mohan, M. Parker, M. Wehbi, and P. Douglass, "Idiopathic dilated cardiomyopathy: A common but mystifying cause of heart failure," Cleveland Clinic Journal of Medicine, vol. 69, pp. 481-487, 2002. [3] Y. Gang, J. H. Goldman, P. J. Keeling, M. Reardon, W. J. McKenna, and M. Malik, "Heart rate variability in idiopathic cardiomiopathy: relation to disease severity and prognosis," Heart, vol. 77, pp. 108- 1014, 1997. [4] C. M. Masi, L. C. Hawkley, E. M. Rickett, and J. T. Cacioppo, "Respiratory sinus arrhythmia and diseases of aging: obesity, diabetes mellitus and hypertension.," Biol Psychol., vol. 74, pp. 212- 223, 2007. [5] P. Grossman and E. W. Taylor, “Toward understanding respiratory sinus arrhythmia: Relations to cardiac vagal tone, evolution and biobehavioral functions,” Biol. Psychol., vol. 74, no. 2, pp. 263–285, Feb. 2007. [6] S. Laborde, E. Mosley and JF Thayer (2017) Heart Rate Variability and Cardiac Vagal Tone in Psychophysiological Research – Recommendations for Experiment Planning, Data Analysis, and Data Reporting. Front. Psychol. 8:213. doi: 10.3389/fpsyg.2017.00213. [7] D. B. Keenan and P. Grossman, "Adaptative filtering of heart rate signals for an improved measure of cardiac autonomic control," International journal of signal processing vol. 2, pp. 52-58, 2005. [8] P. Grossman, J. Van Beek, and C. Wientjes, "A comparison of three quantification methods for estimation of Respiratory Sinus Arrhythmia," Psychophysiology, vol. 27, pp. 702-713, 1990. [9] A. Arcentales, P. Rivera, P. Caminal, A. Voss, A- Bayés-Genís, B.F. Giraldo, (2016). “Analysis of Blood Pressure Signal in Patients with different Ventricular Ejection Fraction using Linear and Non-linear Methods”, 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE EMBC). pp. 2700-2703. ISBN: 978-1-4577-0220-4/16. [10] Voss A, Schroeder R, Vallverdú M, et al. Short-term vs. long-term heart rate variability in ischemic cardiomyopathy risk stratification. Frontiers in Physiology. 2013; 4:364. doi:10.3389/fphys.2013.00364. [11] S. W. Porges, "Method and apparatus for evaluating rhythmic oscillations in aperiodic physiological response systems," ed: Google Patents, 1985. [12] P. Grossman, J. Van Beek, and C. Wientjes, "A comparison of three quantification methods for estimation of Respiratory Sinus Arrhythmia," Psychophysiology, vol. 27, pp. 702-713, 1990. [13] S. W. Porges, J. A. Doussard-Roosevelt, C. A. Stifter, B. D. McClenny, and T. C. Riniolo, "Sleep state and vagal regulation of heart period patterns in the human newborn: an extension of the polyvagal theory. ," Psychphysiology, vol. 36, pp. 14-21, 1999. [14] T. Higuchi, "Approach to an irregular time series on the basis of the fractal theory. ," Physica vol. 31, pp. 277-283, 1988. [15] F. Cervantes-De la Torre, J. I. González-Trejo, C. A. Real-Ramírez, and L. F. Hoyos-Reyes, "Fractal dimension algorithms and their application to time series associated with natural phenomena," Journal of Physics: Conference Series, vol. 475, p. 012002, 2013. [16] M. Pierychlski, "Application of Higuchi Fractal Dimension in Analysis of heart rate variability with artificial and natural noise," Recent Advances in Systems Science, pp. 79-82. [17] Gomes, Rayana L., Vanderlei, Luiz Carlos M., Garner, David M., Vanderlei, Franciele M., & Valenti, Vitor E.. (2017). Higuchi Fractal Analysis of Heart Rate Variability is Sensitive during Recovery from Exercise in Physically Active Men. MedicalExpress, 4(3), M170302 [18] H. A. Sturges, "The choice of a class interval," Journal of the American Stadistics Association, vol. 21, pp. 65-66, 1926.