Full text
Saturation behaviour and load-induced thickness change of woven glass fibre fabrics. VIII International Conference on Textile Composites and Inflatable Structures STRUCTURAL MEMBRANES 2017 K.-U.Bletzinger, E. Oñate and B. Kröplin (Eds) Saturation behaviour and load-induced thickness change of woven glass fibre fabrics JÖRG UHLEMANN*, DANIEL BALZANI†1,2, NATALIE STRANGHÖNER*, MEHRAN MOTEVALLI†1 * Institute for Metal and Lightweight Structures University of Duisburg-Essen 45117 Essen, Germany Email: [email protected], web page: http://www.uni-due.de/iml †1 Institute of Mechanics and Shell Structures Technical University of Dresden 01219 Dresden, Germany Email: [email protected] - Web page: http://www.imf.tu-dresden.de/ †2 Dresden Center for Computational Materials Science (DCMS) 01062 Dresden, Germany Web page: http://dcms.tu-dresden.de/de/ Keywords: Glass fibre fabrics, stress-strain behaviour, saturation behaviour, secant modulus, Poisson’s ratio, thickness change. Summary. The stress-strain behaviour of woven and coated technical textiles for structural purposes is well known to be anisotropic, nonlinear and viscoelastic. Tensile tests with cyclic loads on woven structural fabrics show a saturating behaviour regarding the stress-strain characteristics. Permanent strains are well known to be considerable, particularly in the first load cycles. However, the increase of permanent strains reduces in the following load cycles until only negligible additional permanent strains are observed. In common experimental test practice for structural fabrics, three to five load cycles are applied in total. Results show, that the saturation process may be considered progressed at that point, but not yet finished. In general, elastic material behaviour could be adopted for material modelling in the framework of a numerical analysis when the saturation is finished by an acceptable tolerance. The present paper investigates, whether and when the saturation process is completely finished for a woven glass fibre fabric. For this purpose a specific experimental protocol was developed where longitudinal and transverse strains are considered in uniaxial tensile tests with multiple load cycles. Furthermore, in order to reach beyond the state-of-the-art linear-elastic material model, a new nonlinear anisotropic hyperelastic material model formulated in a full three-dimensional continuum mechanics setup can be considered. That means, that a change in thickness due to axial loading may be taken into account. For this reason, a protocol was developed such that the thickness change is also measured in the saturation tests. The results from these investigations are presented and interpreted in the present paper. 229
J. Uhlemann, D. Balzani, N. Stranghöner and M. Motevalli 2 1 INTRODUCTION The stress-strain behaviour of woven fabrics is known to be anisotropic, nonlinear and inelastic in general, see Figure 1. But it is also well known that nonlinearity and permanent strain increments decrease from load cycle to load cycle, particularly in the first load cycles. In common experimental test practice linked to textile architecture, three to five repeated load cycles are used to stabilise the stiffness behaviour in uniaxial or – more typical – biaxial tensile tests aiming to derive stiffness parameters [1–4]. Only two investigations are known in which ten or twenty load cycles were examined [5, 6]. Therein, the longitudinal strain development of PVC-coated polyester fabric was analysed, but transverse strains were disregarded. Up to now, no studies with multiple load cycles are known for PTFE-coated glass fibre fabrics, besides PES-PVC the other mostly used material for textile architecture. Moreover, the material’s residual or permanent strain has to be considered in the compensation planning in order to ensure a certain safe level of prestress in the structural membrane. Altogether, it always seemed justified to presume elastic material behaviour for the structural analysis in the framework of a membrane structure’s design verification. But, up to now, this presumption has never been thoroughly investigated and proven. Is the material behaviour really properly saturated after three or five load cycles? Figure 1: Typical stress-strain diagram for a glass-PTFE fabric under biaxial stress ratio warp:fill 1:1 showing nonlinearity, inelasticity and anisotropy The first aim of this contribution is to investigate whether and when a woven glass-PTFE fabric saturates, i. e. gets into a stable state where the stiffness parameters do not vary significantly anymore from load cycle to load cycle. This state is also referred to as the “stable state of a woven fabric” in [3], there assumed to be reached within five load cycles with acceptable tolerance for practical applications. The second aim is to investigate the load-induced change in thickness for the investigated glass fibre fabric. For the currently used plane-stress linear-elastic constitutive model, a change in thickness is not considered. However, for the development of a new anisotropic polyconvex hyperelastic material model formulated in a full three-dimensional continuum 230
J. Uhlemann, D. Balzani, N. Stranghöner and M. Motevalli 3 mechanics setup in the sense of [7, 8], knowledge about this physical property is required. Different methods for measuring the thickness of a coated fabric as well as results for thickness and load-induced thickness changes are presented and discussed. 2 MATERIALS AND METHODS The investigated material is a PTFE-coated glass fibre fabric. Table 1 illustrates basic characteristics of the material as measured in the Essen Laboratory for Lightweight Structures (ELLF) at the University of Duisburg-Essen. Due to the measured tensile strength ft it can be classified as type II according to the harmonised classification in [9], although it is quite near to a type III. Uniaxial cyclic strip tensile tests were performed on the 20-kN biaxial test rig of the ELLF. The test setup is illustrated in Figure 2. The reason for using a biaxial test rig for uniaxial tests was the ability to measure in-plane transverse strain and to have enough space to realise thickness changes and surface roughness measurements during the tensile tests. Longitudinal and transverse strains in the membrane plane were detected optically by a camera system continuously tracking four markers in the measurement field. Table 1: Characteristics of the investigated glass-PTFE-material Property Standard Measured value Unit Tensile strength ft Warp / Fill Mean DIN EN ISO 1421 – strip method 135.5 / 117.5 kN/m 5%-fractile* 132.1 / 112.0 Type** according to [9] II - Total weight DIN EN ISO 2286-2 877 g/m2 Thickness DIN EN ISO 2286-3 0.57 mm Weave - Plain weave 1/1 - Yarn density Warp / Fill DIN EN 1049 12.3 / 14.4 yarns/cm Yarn size Warp / Fill DIN EN ISO 2060 1360 / 1360*** dtex * according to EN 1990 with a fractile factor kn = 2.33 ** according to proposed classification in [9] based on the measured tensile strength ft *** manufacturer information Three tests with yarn-parallel warp strips and three tests with yarn-parallel fill strips were conducted for statistical reasons. The load rate was set to 1.0 kN/m/s. Additionally, one test in each fabric direction was scheduled with a load rate ten times lower, i. e. 0.1 kN/m/s, in order to check whether the load rate had an impact on the recorded data. Fifty regular load cycles (LCs) have been performed in each test. The maximum test stress in each cycle was 25 % of the lower tensile strength ft,min given in the material data sheet: max = 116/4 = 29 kN/m. Note that the notion of stress refers here to the stress resultant defined as the integral over the thickness. The chosen maximum test stress matches the typical 231
J. Uhlemann, D. Balzani, N. Stranghöner and M. Motevalli 4 value obtained by applying a safety and strength reduction factor of four in the field of structural membrane constructions. The minimum test stress in each cycle was zero. In order to ensure that creep processes were completely finished before load cycle No 50, a hold time of 30 minutes on the maximum test stress was scheduled in the 49th load cycle. After load cycle No 50, another hold time of 60 min. on max was scheduled. This procedure was only chosen for providing time to perform thickness and roughness measurements with different methods. The complete load protocol is given in Figure 3. Figure 2: Test setup for the uniaxial cyclic tensile tests 48x LC49 30 min. LC50 LC51 60 min. 15 min. Time Membrane stress 0.25ft Figure 3: Load protocol of the uniaxial cyclic tensile tests Strip test specimen Roughness measurement device One of the markers for optical longitudinal and transverse strain measurement “Thickness” change transducer Underlying steel plate 232
J. Uhlemann, D. Balzani, N. Stranghöner and M. Motevalli 5 Preliminary studies on the thickness measurements with different measurement devices such as a thickness tester according to EN ISO 2286-3 [10], a digital calliper, a digital micrometer screw and a microscope as an optical method revealed that the result depends – partially heavily – on the chosen measurement device, see Table 2. This is assumed to be mainly due to different pressures normal to the membrane surface applied by the different devices. Apparently, the investigated material is quite sensitive to this impact. But also the different surface areas covered by the devices could possibly affect the results because single ridges on the surface are considerable higher than others. Table 2: Different thickness measurement results obtained by different measurement methods for one and the same test sample piece Measurement device / method Mean thickness* [mm] Thickness tester acc. to DIN EN ISO 2286-3 0.53 Digital calliper 0.52 Digital micrometer screw 0.50 Evaluation of microscopic cross section 0.52 Displacement transducer with underlying steel plate 0.54 * Mean of four single measurements per method, rounded to two decimal places. For future considerations of the thickness and thickness change in a 3D material model an extensive, reproducible and non-invasive measurement method is required. Finally, it was decided to measure the thickness of the virgin material with the same method as developed for detecting the thickness change: a displacement transducer normal to the membrane surface with a steel plate lying between the transducer and the membrane surface, see Figure 4. The steel plate’s surfaces are smoothed. To avoid any significant bending of the steel plate under the spring force of the transducer, the thickness of the steel plate is chosen to t = 10 mm while the length and width of the steel plate were l = 75 mm and b = 25 mm. Of all compared mechanical thickness measurement methods, the transducer with steel plate underlayment led to the highest values, see Table 2. This indicates that this method is least affecting the measurement. If – for simplification reasons – a constant distribution is assumed, the stress between the steel plate and the membrane caused by the dead load of the steel plate and the transducer spring force becomes only 0.0009 N/mm2, calculated with a given spring constant of D = 0.056 N/mm according to the producer’s data and an initial displacement of the spring of 4.5 mm. As a comparison: the stress due to the standardised thickness measurement according to EN ISO 2286-3 is ten times higher! Moreover, the transducer-steel plate combination covers the greatest area and spans from peak to peak in this area, see also Figure 4. Both features combined, increases the probability to cover peaks and leads to larger values. On the contrary, the more locally working measuring devices as thickness tester, calliper and micrometer screw (listed in order of increasing “locality”) – and also the evaluation of microscopic cross sections – have a lower probability to cover the highest peaks. 233
J. Uhlemann, D. Balzani, N. Stranghöner and M. Motevalli 6 In order to ensure a high quality of the thickness change measurement with the transducersteel plate combination, the planar position of the steel plate within the test setup was checked before each test in the individual setup. Figure 4: Measurement of thickness and thickness change: displacement transducer with a steel plate lying between transducer and membrane surface (not drawn to scale) In fact, the ridge heights deviate. This is indicated in Figure 4. The chosen measurement method actually detects the membrane’s “maximum ridge distance” in the area which is covered by the steel plate. This is in principle very similar to all other mechanical methods described above: they all measure the maximum thickness in the area covered by the measurement device – disregarding that they might reduce the maximum by compressing particularly the highest ridges. During the cyclic tensile tests, the change of the ridge distance was continuously recorded with the transducer-steel plate combination. Additionally, the surface topography of the membrane was measured before and in the final phase of the tests under full load with a roughness measurement device within a range of 17.5 mm, see Figure 2. The surface roughness results are not presented in this paper. 3 EXPERIMENTAL RESULTS AND DISCUSSION 3.1 General Longitudinal and in-plane transverse strains were directly recorded by the optical measurement system of the biaxial test rig. The thickness change was externally recorded as the ridge distance change by the displacement transducer with underlying steel plate. The results of the strip tests with stress in warp and fill direction are presented and discussed in this section. The interpretation focusses on whether and when the stress-strain behaviour saturates, i. e. becomes elastic. As main indicators, the elastic moduli in form of the secant moduli and in-plane Poisson’s ratios are calculated for each load cycle separately. 234
J. Uhlemann, D. Balzani, N. Stranghöner and M. Motevalli 7 3.2 Longitudinal and transverse strain in the membrane plane Figure 5 shows the results of all three “fast” tests and the one “slow” test in warp direction as strain versus time diagrams until the end of the 50th load cycle. In general, the deviations over all tests are low. Even the test with low stress rate does not result in significantly different strain values. Looking only on the transverse strains, the first fast test appears to be an outlier with much lower absolute strain values than the other test specimens. The turning points of longitudinal strains (minimal and maximal value in each cycle) saturate apparently after ca. ten load cycles at a strain level of approximately = 1.9 %. Then, the permanent strains have also saturated. During the hold time in the 49th load cycle, creep strain is negligible. Figure 5: Longitudinal strain and transverse strain in membrane plane vs. time for all cyclic tensile tests in warp direction (timeline of the slow test compressed for comparability reasons) However, transverse strain does not seem to saturate at all. Even after 48 load cycles with full design stress a clearly visible growth of strain is observed. Additionally, creep strain during the hold time is increasing constantly. After 30 minutes, a growth of ca. 10 % strain relating to the beginning of the hold time is observed and still the strain-time curves show no evidence to converge. Surprisingly, this happens while at the same time no creep is detected in longitudinal direction. The recorded data appear to be independent of the stress rate. Remarkable is that the transverse strains are greater than the longitudinal strains, although this is known to be typical 235
J. Uhlemann, D. Balzani, N. Stranghöner and M. Motevalli 8 for glass fibre fabrics! Figure 6 shows the results of all three “fast” tests and the one “slow” test in fill direction as strain versus time diagrams, again until the end of the 50th load cycle. Due to the complex test setup, the camera temporarily lost two markers in the 3rd fast and in the slow test. This is marked in Figure 6. These failures could be fixed within a short time so that the rest of the test delivered reliable data. Figure 6: Longitudinal strain and transverse strain in membrane plane vs. time for all cyclic tensile tests in fill direction (timeline of the slow test compressed for comparability reasons) The first fast test shows a very different behaviour than all the others: the absolute strain magnitudes are considerable smaller in general and even decrease over time. All other test specimens responded very similar to each other so that single curves appear to be invisible in the diagram. Saturation is observed after approximately ten load cycles. The maximum and minimum strain values are constant afterwards for all load cycles and even during the hold time in the 49th load cycle. That means, all creep is removed in the load cycles before. As for the warp tests, there is no significant difference observed between the high and low stress rates. During fill stressing, the transverse strains are smaller than the longitudinal strains – except for the first fast test. In order to investigate whether elastic parameters saturate in the same manner as the strain values, two linear-elastic parameters are derived for each load cycle i: the elastic modulus as secant modulus, calculated as the longitudinal strain increment L,i over the stress increment i and First fast test: strain decareases in longitudinal and transverse directrion over load cycles Camera temporarily lost two markers 236
J. Uhlemann, D. Balzani, N. Stranghöner and M. Motevalli 9 Poisson’s ratio as the negative transverse strain increment T,i over the longitudinal strain increment L,i. For example, the determination of the elastic moduli is indicated for fill direction in Figure 7. It can be recognised that nonlinearity decreases over the load cycles. The results for the elastic moduli and the Poisson’s ratios are illustrated in Figure 8. Figure 7: Determination of elastic moduli, exemplarily illustrated for fill direction in load cycle No 1 (left) and load cycle No 50 (right) WarpstressingFillstressing Figure 8: Saturation behaviour of elastic parameters 237