Full text
Long-term desalinated water demand and investment requirements: a case study of Riyadh O. K. M. Ouda, Y. Khalid, A. H. Ajbar, M. Rehan, K. Shahzad, I. Wazeer and A. S. Nizami ABSTRACT The Kingdom of Saudi Arabia (KSA) is situated in an arid region and faces a chronic challenge to meet its increasing water demand. Riyadh is the capital of KSA and home to about six million people. The water demand is mostly met by groundwater resources (up to 48%), while the desalination plants cover the rest of the water supply requirements. There is a potential risk of a significant gap in water demand–supply due to the retirement of old desalination plants. This study, therefore, developed a probabilistic model to forecast desalinated water demand in Riyadh for domestic purposes up to the year 2040 based on three scenarios: low growth, the most likely (mean), and high growth scenario. The results showed that an investment of about US$6.24, 11.59, and 16.04 billion is required to meet the future domestic water demand of the city for the next 25 years based on low, mean, and high growth scenarios, respectively. Moreover, a strong commitment to public–private partnership is required to remove the fiscal budget burden related to the desalination along with public awareness campaigns to reduce per capita water consumption, upgrading the water tariff system and using renewable energy to run desalination plants. O. K. M. Ouda Prince Mohammad Bin Fahd University, Al-Khobar, Saudi Arabia Y. Khalid Institute of Energy Technologies, Polytechnic University Catalonia, Barcelona, Spain A. H. Ajbar I. Wazeer Department of Chemical Engineering, King Saud University, Riyadh, Saudi Arabia M. Rehan K. Shahzad A. S. Nizami (corresponding author) Center of Excellence in Environmental Studies (CEES), King Abdulaziz University, Jeddah, Saudi Arabia E-mail: [email protected] Key words |desalination plant, groundwater resources, probabilistic model, water demand, water supply LIST OF ACRONYMS AND ABBREVIATIONS ED electro-dialysis GHG greenhouse gases HABs harmful algal blooms KACARE King Abdullah City of Atomic and Renewable Energy KSA Kingdom of Saudi Arabia MED multi-effect distillation MCS Monte Carlo simulation MIGD million imperial gallons per day MSF multistage flashing MOWE Ministry of Water and Electricity PPP public–private partnership RAK Ras-Al-Khair RO reverse osmosis SWCC Saline Water Conversion Corporation UFW unaccounted-for-water VC vapor compression WHO World Health Organization WTE waste-to-energy INTRODUCTION Scarce water supply in the Middle East region is a strategic and chronic problem that can be traced back to the early This is an Open Access article distributed under the terms of the Creative Commons Attribution Licence (CC BY 4.0), which permits copying, adaptation and redistribution, provided the original work is properly cited (http://creativecommons.org/licenses/by/4.0/). 1© 2017 The Authors Journal of Water Reuse and Desalination |in press |2017 doi: 10.2166/wrd.2017.107 Uncorrected Proof
1970s (Allan ;UNDP ). The Kingdom of Saudi Arabia (KSA) struggles with water scarcity, as it is located in the driest spot of the Middle East and has extremely hot summers and dry winters (SGS ). The country has no perennial lakes or rivers; the only reliable natural water source for domestic water supply is groundwater (World Bank ;Ouda ). In 2010, the total natural water resources that could be used in the country for all purposes, including agriculture, industrial, commercial, and domestic was around 188 m 3 per capita. This figure is far below the threshold limit of 500 m 3 per capita per year, set by the World Health Organization (WHO) for water stress countries (Jagannathan et al. ;UNDP ). An enormous socio-economic development has occurred in KSA over the last few decades, as a result of revenues generated from high crude oil production (World Bank ,;Nizami et al. a,b;Shahzad et al. ). In the early 1970s, KSA’s population was 7 million. By 2010 it had increased to around 27 million, with an average growth rate of 3.4% (Ismail & Nizami ;Nizami et al. a,b). Urbanization levels also increased from 50 to 80% during this period (CDSI ;Ouda et al. ;Nizami et al. ). Consequently, the water demand in all sectors of KSA rose substantially (Abderrahman ;Ouda a, b). The water demand–supply gap in 2010 was around 11.5 billion m 3 (Table 1), which was mainly bridged by depletion of groundwater resources (UNDP ). A significant increase in water demand by domestic, industrial, and agriculture sectors will exert additional pressure on water resources and challenge the socio-econ- omic development plans of the KSA’s government (Ouda et al. ). The government has considered desalination of seawater as a strategic option to meet the growing domestic water demand throughout the country (Al-Ibrahim ). Currently, around half of the domestic water demand in KSA is fulfilled by 30 different desalination plants (SWCC ,). These desalination plants are developed in the Red Sea and the coast of the Arabian Gulf, under the authority of the Saline Water Conversion Corporation (SWCC) (SWCC ,). The production capacity of these desalination plants has significantly increased from around 200 million m 3 /year in 1980 to around 1,050 million m 3 /year in 2010 (SWCC ,; MWE ;Ouda ). The future estimations of water demand are critical for water system planning and design, water utilities asset management, and water resources management. These forecasts, along with the role of demand management policies, become more critical in areas of scarce water supplies such as the city of Riyadh (Almutaz et al. ;Rahmanian et al. ). However, despite the extreme importance of water forecasting, there is a very limited amount of literature and data available in KSA that tackles this topic. In fact, the little that exists is mostly outdated (Almutaz et al. ). The scientific literature documents various models for water demand forecast based on deterministic or probabilistic approaches (Arbues et al. ;Davis ;Worthington & Hoffman ; Alshawaf 2008). The selection of a forecast model is driven mainly by the data quality and its level of certainty. The deterministic model will be very efficient when the data are both high quality with high certainty levels (Cheng & Chang ). However, in situations where the main explanatory factors or variables are uncertain, the effectiveness of such deterministic models will be limited (Khatri & Vairavamoorthy ). This applies in particular for countries like KSA, where the temperature is the only variable (Almutaz et al. ). Other Table 1 |KSA sustainable water resources yields vs. water demand in 2010 (Ouda 2015) Water resources sustainable yields Quantity (million m 3 /year) Groundwater 3,850 Surface water 1,300 a Total conventional sources 5,150 Treated wastewater 240 Desalinated water 1,050 Total non-conventional sources b 1,290 Total water resource yields c 6,440 Water demand Domestic 2,063 Industrial 800 Agricultural 15,000 Total 17,863 Water demand vs. supply gap 11,423 a Variable depending on rainfall pattern. b The total non-conventional sources include desalinated water, and treated wastewater available in the country every year. c The total water resource yield is the total for both conventional and non-conventional resources. 2O. K. M. Ouda et al. |Long-term desalinated water demand and investment requirements Journal of Water Reuse and Desalination |in press |2017 Uncorrected Proof
potential explanatory variables are categorized by a high degree of uncertainties, including population, family income and housing growth rate, immigration, rigorous water pricing policy, and the inefficient management of the unaccounted-for-water (UFW) (Almutaz et al. ). All these factors make the probabilistic model approach more suitable than a deterministic model for KSA in providing a long-term forecast of water demand and associated investment requirements. A sustainable water policy for Riyadh city requires an assessment of the long-term water desalination demand for domestic purposes, using a probabilistic model approach to implementing appropriate capital expenditures and develop new plans. Therefore, this study aims to determine the long-term investment needs for seawater desalination in Riyadh city for the next 25 years to meet the domestic water supply, with an ambition to maintain a sustainable water supply through a network of desalination plants. The study includes, in particular, the forecast of Riyadh’s water domestic water demands up to the year 2040, assessment of the water supply options to meet the demands, suggestions for the appropriate desalination technologies based on the current practices and standards, and estimations of the necessarily required investments. Case study –Riyadh city Riyadh city has a population of about six million which constitutes more than one-fifth of the total population of KSA (CDSI ). The city has a very harsh climate with an average temperature ranging from about 8 WC in winter to 43 WC in summer. The annual evapotranspiration and wind speed vary from 1,168 to 979 mm and 6.5 to 13.9 km/hr, respectively. Humidity and annual rainfall vary from 15 to 51% and about 101 mm, respectively (SGS ;CDSI ;Al- Zahrani et al. ). Due to being a capital and an important industrial center, the city has witnessed a rapid growth in population and socio-economic development during the last few decades that has exerted tremendous pressure on the city’s water resources (Ouda ). The water supply for Riyadh city comes from local groundwater (about 48%) and desalination plants (about 50%) that are installed on the Arabian Gulf, about 450 km to the east of the city (Almutaz et al. ). The remaining minimal amount (about 2%) comes from treated wastewater that is only used for landscape irrigation (Almutaz et al. ; Miandad et al. a;Khan et al. ). The groundwater is produced from the shallow aquifer around Wadi Hanifa and its tributaries, and the deep wells of the Minjur and Wasia-Biyadh aquifers (Al-Mutaz ). The groundwater extraction rate was around 29.2 million m 3 in 1964 and increased to around 4,369 million m 3 in 2011 (Al-Mutaz ;MWE ,;Al-Zahrani et al. ). The agriculture sector consumes the majority of extracted groundwater, and only around 320 million m 3 of groundwater is utilized in the domestic water supply (Ouda 2013). In 2011, approximately 338 million m 3 of desalinated water was supplied to Riyadh city from the following three desalination plants that are located in the Arabian Gulf: 1) Multistage flashing (MSF) plant I: Its operational commencement year was 1982, and it currently has a production capacity of 118,447 m 3 /day. 2) MSF plant II: Its operational commencement year was 1983, and it currently has a production capacity of 815,185 m 3 /day. 3) Reverse osmosis (RO) plant: its operational commencement year was 2002, and it currently has a production capacity of 78,182 m 3 /day (SWCC ). In 2010, the cost of desalinated water production was US$0.80/m 3 , and the cost of pumping and distributing desalinated water to the end user was about US$1.2/m 3 (SWCC ). The SWCC has been operating Ras Al-Khair (RAK) desalination plant since 2014. The plant is a hybrid desalination plant that combines both the MSF and RO technologies. The plant is located in RAK industrial city along the Arabian Gulf. On a daily basis, the plant produces 728,000 m 3 of water that serves around 3.5 million people in Riyadh city. The project construction cost was approximate US$7.2 billion (Water Technology ). The residential water consumption per capita in Riyadh city was about 308 liters/day in 2010 (MOWE ). This value is larger than the consumption levels in many other developing countries, but still comparable with the consumption levels in other Middle East countries (Almutaz et al. ). A significant share of the city’s water supply system (up to 30%) is also covered by large UFW (MOWE ). This is mainly due to leaks in distribution systems 3O. K. M. Ouda et al. |Long-term desalinated water demand and investment requirements Journal of Water Reuse and Desalination |in press |2017 Uncorrected Proof
that are present in old areas of the city. The cost of operating desalination plants and distribution of clean water to consumers is US$2/m 3 . This price is extremely high, even though KSA uses its cheaply produced oil to meet the energy requirements of the desalination plants (Ouda a). The cost of treating local groundwater is also high, estimated at US$0.5/m 3 , while contribution cost is very low in comparison to desalinated water transportation cost, where water is pumped from the coastal area (about 400 km) to Riyadh city. The water as a commodity is virtually free throughout the country, as the government gives a huge subsidy on water consumption. Domestic consumers pay less than 5% of the production and distribution cost of water (Ouda b). Consequently, water is significantly underpriced. This makes water demand artificially high and ultimately leads to inefficient use (Ouda ). Very recently, the KSA’s government adopted a new water tariff for domestic water consumers. The new tariff raises the water cost for domestic consumer by almost 70%. It is worth noting that even with the new tariff, water is still heavily subsidized by the Saudi government and the new tariff impact on domestic water demand has not been realized as yet (Ouda ). METHODOLOGY Water demand forecast using probabilistic model The development of a probabilistic forecast model for any city relies on the selection of explanatory variables followed by the assignment of probability density functions to each selected variable (Almutaz et al. ). The forecast time frame is set to the year 2040. This matches with the average useful life of a desalination plant which is 25 years. The average household income is the first selected explanatory variable (Table 2). In some countries, the water bills are a significant fraction of household income. However, in the case of KSA, where the government largely subsidizes water cost, the household income has a minimum indirect effect on water consumption. For example, higher income or wealth can be used for luxury goods such as dishwashing machines and swimming pools that lead to higher water consumption. Moreover, households with high income possess large houses that tend to consume larger quantities of water. The average household income was assumed to be normally distributed with an average growth rate of 2.2%, while the standard deviation is restricted to 10% of the mean (Table 2). The water forecast model also depends on population size and its growth. Riyadh city attracts both national and international immigrants. Immigration from outside the country, in particular, depends on the economic opportunities of the oil-rich country. The uncertainties incorporated in local population growth are therefore justified. Currently, the Saudi population is growing at an annual rate of 2.95% (Almutaz et al. ). Planning authorities predict a decline in population due to several socioeconomic factors. Data from the Central Department of Table 2 |Mathematical expressions and forecasting model variables (Almutaz et al. 2012, 2013) Mathematical expressions and models’variables The total water use was estimated by the following standard functional population model: Qy¼Nq where Q y is the total annual water use in year (y), Nthe population at year (y), and q is the water use per capita The water use (q) per capital was assumed to depend on the following explanatory variables: ln q¼aþblog (Income) þclog (Household size) þdlog (Temp) whereas, income is the normal distribution with an average growth rate of 2.2%, while the standard deviation is restricted to 10% of the mean. Household size, including the average number of persons per household, is triangular probability distribution. The mean is assumed to increase by an annual growth rate of 2.4% from the base value of 5.86. The minimum and maximum values of ±1.5% of mean. Temperature is normal distribution with a standard of deviation of 1 WC The model parameters were determined using @Risk. The population (N) forecast was based on the following methodology: The population growth rate is based on the data for annual growth rate for Saudi and non-Saudi population, currently the annual growth rate of Saudi’s population is 2.95%, while it is 2.895 for non-Saudi’s population. The change in annual growth rate of Saudi’s population is 0.16%, while it is 0.26% for non-Saudi’s population Given the above nominal data, the growth rate of Saudi was computed (resp. non-Saudi) at year_i through the following formula: Growth rate of Saudi at year_i ¼Annual growth rate for Saudi –Change in growth rate for Saudi*(year_i - reference year) The total population of Saudi (resp. non-Saudi) at year _i is then calculated by: Total population of Saudi at year_i ¼Population at reference year*Exp. [growth rate of Saudi at year _i*(year (i) - reference year)] 4O. K. M. Ouda et al. |Long-term desalinated water demand and investment requirements Journal of Water Reuse and Desalination |in press |2017 Uncorrected Proof
Statistics indicate that the population growth rate will decrease with a mean value of 0.16%; minimum of 0.1% and a maximum of 0.25% (Almutaz et al. ). The current annual growth rate of 2.90% was assumed for the non-Saudi population. The authorities also predict a decrease in the flux of international immigrants, which will result in a decrease in the growth rate with a mean of 0.26%; a minimum of 0.2% and a maximum of 0.3%. The change in the growth rates is, therefore, best described by a triangular probability distribution that is based on three parameters, including mean, minimum, and maximum (Table 2). The household size and an average number of persons per household are other important explanatory variables. Data from the Central Department of Statistics indicate that the number of housing units will increase annually by a rate of 2.3% (Almutaz et al. ). Since the population growth was assumed to follow a triangular probability distribution, it seems logical that a similar distribution was selected for the household size. The parameters of the distribution were taken from the demographic forecast. The minimum and maximum values of ±1.5% of mean were taken for the triangular function, which was assumed to increase by an annual growth rate of 2.4% from the base value of 5.86 in 2011 (Table 2). Temperature is an important explanatory variable for arid Riyadh city, as the temperature can change from 45 WC in summer to 5 WC in winter. The temperature is therefore expected to affect the water consumption significantly. The monthly mean of daily maximum temperature was the only weather variable selected in the predictive model. It was assumed to have a normal distribution with a standard deviation of 1 WC(Table 2). The probabilistic water forecast model also includes the effect of UFW and conservation measures. According to the data collected from the Ministry of Water and Electricity (MOWE), UFW accounts for 30% of total water production, 50% of residential, and the rest for non-residential purposes, including commercial and public sectors. The ministry has a long-term plan to reduce such high-current UFW levels to below 15%. However, only half of the current UFW is estimated to be the real loss (i.e., undetected network leakage and water meter deficiencies) that can be reduced by UFW management. Therefore, the actual target is to reduce the real loss down to 5% by 2041. These assumptions dictate setting the expected UFW to 10% and restricting its possible values to between 0 and 20%. A triangular distribution having a mean of 10% and the minimum and maximum values between 0 and 20% is suitable for UFW. The surface water was not included in the water forecast model. The reasons for this are the little rain and whatever surface water is available is used only for agricultural purposes. Moreover, the dominant climatic features of the city are high temperature, low humidity, and hot winds resulting in high evaporation rates (Al-Saud ). The water conservation measures that are planned in the city include the replacement of a number of current fixtures with more efficient ones. A target of 90% is set for new fixtures by 2041. The most likely set of assumptions, among many different assumptions examined, resulted in a range of 20–25% reduction. A uniform distribution is chosen to account for such water conservation measures. The upper and lower ranges of this distribution were set to remain within 20% of the average annual savings of 5% (Almutaz et al. ,). After forming the forecast model, Monte Carlo simulation (MCS) was employed to determine the point demand model with specified variable uncertainties, which made a probabilistic demand model to obtain the total water consumption distribution. The @Risk software package, version 6.0 by Palisade Corporation (www.palisade.com) was used to carry out the MCSs. This software can be used for a number of probability distribution functions. It allows the simulations to generate random numbers and specify sampling rules, together with setting graphics and other scenario options. A confidence interval of 90%, in which potential water demand would fall, was projected and formed with 5th and 95th percentile values. The 5th, 95th, and mean values roughly represent the low, high, and most likely growth scenarios, respectively. Water demand–supply gap The typical lifetime of a desalination plant ranges between 25 and 30 years, depending on the type of technology (Raluy et al. ). The existing old plants, if refurbished, will provide an additional 15 years’lifetime to the plant (Schiffler ). Accordingly, the useful life of a desalination plant was adopted to estimate the water demand–supply gap, while the gap in the water supply was assessed based 5O. K. M. Ouda et al. |Long-term desalinated water demand and investment requirements Journal of Water Reuse and Desalination |in press |2017 Uncorrected Proof
on an estimation of the available desalinated water quantity and the model feeding of future demand (Sommariva et al. ;IAEA ;Raluy et al. ). The water supply capacity of the existing desalination plant was calculated based on the following considerations. In the years, 2023 and 2024, respectively, both desalination plants MSF I and MSF II will complete their lifetime with a total useful life of 40 years from the date of operation and will maintain the same production rate until complete amortization. Second, the amount of water, 906,600 m 3 /day, to be supplied by the local groundwater resources, was assumed to remain the same until the year 2040. The reason for this includes the ongoing debate on whether the groundwater in KSA can be considered as a renewable or not (Foster & Loucks ). If the groundwater is renewable, then an increasing use of groundwater will be assumed. While, if the groundwater is not considered as a renewable, then a decreasing use of groundwater will be assumed. Therefore, a constant supply of groundwater for the future was assumed until the year 2040. Third, the RAK plant (900,000 m 3 /day) will supply the desalinated water for a total duration of 40 years from the year 2014 onward. Fourth, the amount of water, 78,182 m 3 /day, to be supplied by RO plant, was also assumed to remain the same until the year 2040. Total water supply from 2012 until 2040 is shown in Figure 1. Initially, the water supply for all scenarios was around 1,918,000 m 3 /day in 2011. This has been increased to 2,818,000 m 3 /day by 2014 due to the inclusion of the RAK plant. Afterwards, the water supplies will be reduced to the amount of 1,884,826 m 3 /day with the retirement of old MSF plants. This trend will remain constant until 2040. Desalination technologies The desalination technologies (Figure 2) are classified as thermal or membrane-based technologies. The membranebased desalination technologies include RO and electrodialysis (ED), whereas the thermal based desalination technologies include MSF, vapor compression (VC), and multieffect distillation (MED) (Al-Karaghouli & Kazmerski ). RO technology is a pressurized filtration process, where a semi-permeable membrane filter is used to allow only water to pass through (Figure 2). The products of RO are fresh water as well as a concentrated solution that remains on the membrane side with high pressure. The process is completed in four steps: (1) pretreatment, (2) highpressure pump, (3) membrane, and (4) post-treatment. RO is widely used for the treatment of saline groundwater and seawater and can be expanded easily from house level to commercial scale (El-Dessouky & Ettouney ;Al-Kara- ghouli & Kazmerski ). Figure 1 |Projected water supply for Riyadh up to year 2040. 6O. K. M. Ouda et al. |Long-term desalinated water demand and investment requirements Journal of Water Reuse and Desalination |in press |2017 Uncorrected Proof
Figure 2 |Schematic diagrams of prominent desalination technologies. 7O. K. M. Ouda et al. |Long-term desalinated water demand and investment requirements Journal of Water Reuse and Desalination |in press |2017 Uncorrected Proof
ED uses a direct electrical current for the separation process, where salt ions are moved selectively through a membrane (Figure 2). The ED unit is completed with the following sub-systems: pretreatment system, low-pressure circulation pump, membranes stack, direct-current power supply, and post-treatment system (Strathmann ;Al-Kar- aghouli & Kazmerski ). MSF is an energy-intensive technology that needs both electrical and thermal energy for operation (Figure 2). The thermal energy, in the form of low-pressure and medium-pressure steam, is used to heat the feed-brine and ejectors for generation of required vacuum in different sections of the unit. Electrical energy is used to run other parts of the unit, including water cooling system, product distillation, brine blowdown, condensation and chemical dosing pumps. After RO, the MSF is the second most-used desalination technology worldwide (Al- Mutaz & Al-Namlah ;Al-Karaghouli & Kazmerski ). The MED process is completed in a series of steps that are maintained at relatively lower pressure levels in comparison to other desalination technologies (Figure 2). At the first stage, the brine temperature is increased to around 70 WC by heat coming from one of many possible sources, including the waste heat from power plants, fossil fuel-based boiler, solar, or other heat sources in order to evaporate some of the brine left inside at the low pressure (Al-Mutaz & Al-Namlah ). In the second stage, the produced water vapors are transferred inside a tube for extra boiling that produces the water vapors in a series fashion. The interest in the MED process in the last few decades has increased significantly, and it has gained a bigger market share (Al-Karaghouli & Kazmerski ). VC technology utilizes the heat produced by the compression of water vapors to evaporate salt water (Figure 2). The process is completed in two steps: thermo VC and mechanical VC. The feed water enters the VC process through a heat exchanger and generates water vapors in the evaporator. The water vapors are then compressed by mechanical or thermal compression methods (Al-Karaghouli & Kazmerski ). A comparison between the three dominant desalination technologies, including the MSF, MED, and RO is presented in Tables 3 and 4, based upon three sets of criteria: merits and limitations, computable (quantitative), and non-comput- able (qualitative) criteria. RESULTS AND DISCUSSION Water demand–supply gaps The results of water demand forecast for Riyadh city are presented in Figure 3, which shows the annual water demand for the 5th (low-growth scenario) and 95th (high-growth growth scenario) percentiles and the most likely scenario (the mean). The most likely projected water demand for the year 2040 will be about 2,846 ×10 3 m 3 /day. This value lies between the limits of 2,414 ×10 3 m 3 /day (low-growth scenario) and 3,240 ×10 3 m 3 /day for 95% (high-growth Table 3 |Comparisons of selected desalination technologies based on their merits and limitations (Napoli & Rioux 2016) Detail Merits Limitations MSF Power source is combined-cycle gas turbine cogeneration Maintenance and operational costs are lower Capital cost is higher Sensitivity to salts is lower Energy consumption is higher MED Power source is combined-cycle gas turbine cogeneration Maintenance and operational costs are lower Capital cost is higher Sensitivity to salts is lower Energy consumption is higher RO Power source is electric grid Energy consumption is overall low Maintenance and operational costs are higher Membrane fouling due to HABs Under high salt concentrations and impurities, the process reliability is affected 8O. K. M. Ouda et al. |Long-term desalinated water demand and investment requirements Journal of Water Reuse and Desalination |in press |2017 Uncorrected Proof
scenario). The above-mentioned projected water demand can also be calculated using the water deficit between available water supplies and projected demand. The total water demand–supply gaps for all three scenarios are presented under two different time period zones, as shown in Figure 4. During the first time period zone, the water supply would meet the water demand, whereas the water demand will exceed the water supply during the second time period zone. This change will start from the year 2024, where the demand and supply curves intersect with each other, as shown by an arrow in Figure 4. The water deficit for 2024 was 30% for a 95% demand scenario that increased to 72% (about 1,366 thousand m 3 /day) in 2040. Similarly, there will be a water deficit of 20% in 2024 for a 5% demand scenario that further increased to 28% (531 thousand m 3 /day) in 2040. Regarding the mean (the most likely scenario), the deficit value for 2024 is 25%, increasing to 51% (981 thousand m 3 /day) by 2040 (Figure 4). Suitable desalination technologies In cross comparison (Tables 3,4and Figure 2), RO is preferred over MED and MSF, as there is a better understanding today of the pretreatment requirements of the RO process. However, RO’s ability to handle feed-in seawater with variable quality is still a major drawback. This is particularly the case for Arabian Gulf water with high level of harmful algal blooms (HABs) and salt concentration. The HABs tend to cause membrane fouling with an accumulation of organic and particulate materials and, ultimately, results in operational problems of the RO plants. On the other hand, high thermal efficiencies, savings in fuel costs, operation at a low temperature to avoid corrosion and scaling, and ability to operate with feed-water that has a large salt concentration are some of the advantages of the MED process (Tables 3 and 4). However, in many cases, and specifically for larger plants, the lowest cost is obtained by MED when joining power and water production (Tables 3 and 4). Seawater desalination together with power generation provides a promising and better usage of fuel (Ouda , 2016). In this regard, MSF desalination plants can allow cogeneration of water and electricity. Therefore, the cost of the plant can be distributed to products such as water and electricity, if power generation is considered from MSF (Tables 3 and 4); although the unit operating Figure 3 |Projected water demand for Riyadh up to year 2040. Table 4 |Comparison among the dominant desalination technologies (Ghaffour et al. 2013;Mabrouk 2013;Al-Karaghouli & Kazmerski 2013) Description MSF MED RO Non-computable (qualitative) criteria Maintenance and reliability High High Average Power generation dependency High High Low Robustness High High Less than MSF Future technology options Low Average High Flexibility Low Average High Environmental impact High High Low Feed water sensitivity Low Low High Computable criteria (based upon 15 MIGD (68,184 m 3 /day) plant) Description MSF MED RO Unit operating cost (US $/m 3 ) 1.07 0.83 0.76 Annual operating cost a (US$ million/year) 26.63 20.656 18.92 Operating cost (OPEX) b (25 years) (US$ million) 665.75 516.5 475 Capital cost (CAPEX) c (US$ million) (9 × 15) ¼ 135 (8 ×15) ¼ 120 (7.5 × 15) ¼ 112.5 Total cost (US$ million) 800.75 636.5 585.5 a Annual operating cost ¼(Unit operating cost) (Plant capacity). b OPEX ¼(Annual operating cost) (25 years); (Plant life cycle is considered to be 25 years (Mabrouk 2013). c CAPEX ¼(Unit capital cost) (Plant capacity). 9O. K. M. Ouda et al. |Long-term desalinated water demand and investment requirements Journal of Water Reuse and Desalination |in press |2017 Uncorrected Proof