scieee AI-readable full text Open interactive document viewer

Flexural behaviour and ultimate bending capacity of high-volume fly ash reinforced concrete beams

Dragaš, Jelena,Marinkovic, Snežana,Ignjatovic, Ivan,Tošić, Nikola,Kokovic, Veljko

Abstract

Large number of studies analyzed physical and mechanical properties of high-volume fly ash concrete, but only a few discussed its structural behavior. Material properties are an important input parameter for structural analysis, but they are insufficient for reliable conclusions to be made. This study analyses flexural behavior of reinforced concrete beams made with 63% of low-calcium class F fly ash in total cementitious materials mass, using experimental method and analyzing current code predictions (EN 1992-1-1). The analysis was done by comparing beams made with two longitudinal reinforcement ratios, made with traditional cement concrete (OPC) and high-volume fly ash concrete (HVFAC), both corresponding to concrete class C30/37. Beams were tested in a four-point bending test measuring vertical displacement, crack development, concrete strains and longitudinal reinforcement strains. According to this research, the flexural performance of HVFAC beams is similar to flexural performance of corresponding OPC beams in terms of ultimate bending capacity. The significant difference was noticed regarding cracking extent that was higher in HVFAC beams. Available ultimate bending moments code predictions can be applied on HVFAC beams with similar precision and variation of results, like for OPC beams. However, this cannot be concluded for parameters depending on the cracking behaviour, like cracking moments or deflections. Results and analysis presented in this study indicate that HVFAC can be used in structural elements subjected dominantly to bending, like beams and slabs. More research regarding structural behavior of HVFAC using full-scale long-term tests is needed to develop larger database for reliability analysis.

Full text

Engineering Structures Flexural behaviour and ultimate bending capacity of high-volume fly ash reinforced concrete beams --Manuscript Draft-- Manuscript Number: ENGSTRUCT-D-22-02576R1 Article Type: Research Paper Keywords: High-volume fly ash concrete; Beams; Ultimate bending capacity; Cracks; Deflection; strains Corresponding Author: Jelena Dragaš, Ph.D University of Belgrade Belgrade, Please select SERBIA First Author: Jelena Dragaš, Ph.D Order of Authors: Jelena Dragaš, Ph.D Snežana Marinković, Ph.D Ivan Ignjatović, Ph.D Nikola Tošić, Ph.D Veljko Koković, Ph.D Manuscript Region of Origin: Europe Abstract: Large number or studies analyzed physical and mechanical properties of high-volume fly ash concrete, but only a few discussed its structural behavior. Material properties are an important input parameter for structural analysis, but they are insufficient for reliable conclusions to be made. This study analyses flexural behavior of reinforced concrete beams made with 63% of low-calcium class F fly ash in total cementitious materials mass, using experimental method and analyzing current code predictions (EN 1992-1-1). The analysis was done by comparing beams made with two longitudinal reinforcement ratios, made with traditional cement concrete (OPC) and high-volume fly ash concrete (HVFAC), both corresponding to concrete class C30/37. Beams were tested in four-point bending test measuring vertical displacement, crack development, concrete strains and longitudinal reinforcement strains. According to this research, the flexural performance of HVFAC beams is similar to flexural performance of corresponding OPC beams in terms of ultimate bending capacity. The significant difference was noticed regarding cracking extent that was higher in HVFAC beams. Available ultimate bending moments code predictions can be applied on HVFAC beams with similar precision and variation of results, like for OPC beams. However, this cannot be concluded for parameters depending on the cracking behaviour, like cracking moments or deflections. Results and analysis presented in this study indicate that HVFAC can be used in structural elements subjected dominantly to bending, like beams and slabs. More research regarding structural behavior of HVFAC using full-scale long-term tests is needed to develop larger database for reliability analysis. Suggested Reviewers: Ludwik Grzegorz Golewski, Ph.D Professor, Lublin University of Technology [email protected] Mr. Golewski is a well-known researcher with one of his expertise being fly ash concrete. He studies fly ash concrete from material to complex structural level, and his papers were of great help during my research of fly ash concrete flexural behavior. Katherine Kuder, Ph.D Professor, Seattle University [email protected] A big part of Katherine Kuder’s research was focused on systematic analysis of fly ash concrete, analyzing the applicability of current codes on material properties of concrete. Structural behavior of green concretes was also in her focus, and her work was valuable for better understanding of problems analyzed in submitted paper. Powered by Editorial Manager® and ProduXion Manager® from Aries Systems Corporation Opposed Reviewers: Response to Reviewers: Powered by Editorial Manager® and ProduXion Manager® from Aries Systems Corporation Engineering Structures Editorial Office Editor-in-Chief Dear Editors, Please find attached a research paper titled ‘Flexural behaviour and ultimate bending capacity of high-volume fly ash reinforced concrete beams’ which I hope you will consider for publication in your journal. The paper is co-authored by Snežana Marinković, Ivan Ignjatović, Nikola Tošić and Veljko Koković. This paper presents comprehensive testing and analysis of flexural behavior (ultimate capacity, strain development, cross-section analysis, short-term deflection, crack development and application of EN 1992-1-1 predictions) of beams made with more than 60% of low-calcium fly ash in total mass of cementitious materials. This research aims to motivate larger implementation of fly ash in structural grade concrete, considering great amount that are still available worldwide. Even thou alkali-activated concrete is a very popular ‘green’ alternative to traditional cement concrete, it still has limitations for larger practical application (e.g. heat curing, environmental effect of alkali activators and new preparation technology). Simple replacement of cement with larger amounts of fly ash is a simple way to reduce the amount of cement, but lacks unambiguous proof in structural application. Results presented in this paper can provide a valuable basis for future more comprehensive investigations, and it will contribute to a number of methodologically well-structured papers analyzing flexural behavior of beam elements, such as: Du, Y., Wang, J., Shi, C., Hwang, H.J., Li, N., 2021. Flexural behavior of alkali-activated slag-based concrete beams. Engineering Structures. 229, 111644. Seara-paz, S., González-fonteboa, B., Martínez-abella, F., Eiras-lópez, J., 2018. Flexural performance of reinforced concrete beams made with recycled concrete coarse aggregate. Engineering Structures. 156, 32–45. Looking forward to hearing from you soon. Sincerely, Jelena Dragas, Assistant professor PhD University of Belgrade Faculty of Civil Engineering Bulevar kralja Aleksandra 73, 11000 Belgrade, Serbia T: +381 11/3218-573 M: +381 64/1831-841 Email: [email protected] Web: http://www.grf.bg.ac.rs/fakultet/pro?nid=167 Cover Letter Response to Reviewers’ comments and description of changes in the revised Manuscript ID ENGSTRUCT-D-22-02576, submitted to Engineering Structures Authors’ general response to Reviewer comments: The authors are grateful to the Reviewers for the time dedicated to revising our paper and the provided positive feedback and comments. We have done our best to implement all suggested changes to the manuscript and we are certain this has helped improve its quality. Our responses to the review comments are below, and changes that we have made to the paper are highlighted (red colour) in the revised manuscript submission. Reviewer #1 1) In this paper, the respected authors have experimentally investigated the flexural behavior and ultimate bending capacity of high-volume fly ash reinforced concrete beams. This paper is written well. However, the reviewer believes that the novelty and contribution of the present paper is marginal. A quick search in the internet shows that many papers have been previously published which deal with the structural behavior of high-volume fly ash reinforced concrete beams. For example: Flexural Behavior of High-Volume Fly Ash Concrete Beams, 2015, Transportation Research Record Journal of the Transportation Research Board 2508(2508):22-30, DOI:10.3141/2508-03 Flexural performance of high volume fly ash reinforced concrete beams and slabs, 2020Structures 25(1):868-880, DOI:10.1016/j.istruc.2020.03.071 Flexural behavior of Reinforced Fly Ash Concrete in Comparison to Reinforced Normal Concrete beams in Terms of Cracking Load and Ultimate Load Carrying Capacity, International Journal of Engineering and Advanced Technology (IJEAT), Volume-4 Issue-2, 2014 Response: Thank you for the comment, and suggested references. A detailed state-of-the- knowledge in the area is presented at pages 3-5. An initial search yielded a total of ten studies investigating flexural behaviour of beams made with different amounts of fly ash, but only six studies analysed class F fly ash concrete made with 50% or more of fly ash in cementitious materials mass. These studies were qualitatively analysed and it was concluded that the flexural behaviour of HVFAC beams is not fully explained regarding the influence of fly ash amount on ultimate bending capacity, cracking moments, development of flexural cracks, tension stiffening effect, short-term and long-term deflection. Results from these studies were used to make a database for further quantitative assessment. Only beams with structural grade concrete (cylinder compressive strength higher than 15 MPa) were selected. When analysing the applicability of EN1992-1-1 standards, only beams that had all necessary data for calculation were selected. This yielded twelve beams for comparison of HVFAC and traditional cement concrete, and only eight beams that enabled the application of EN 1992-1-1 code provisions. In order to enable practical application of HVFAC in reinforced concrete structures, it is required to produce a code of practice or a standard which regulates the design of such structures. The reliability of prediction models, usually semi-empirical in standards, largely depends on the extent and quality of experimental data bases, as it is the case with cement concrete structures. In our opinion, each experimental campaign, properly performed and adequately and transparently reported, presents a valuable contribution at the current state-of- the-knowledge in the area. It widens the existing, rather small, experimental data base and increases the reliability of the future code predictions regarding the ultimate and serviceability limit states of reinforced concrete structures made of HVFAC. Notes/actions: SoA: Page 3-lines 17-28; page 4-lines 1-28; page 5, lines 1-11. The contribution of the study has been highlighted in the introduction at page 5, lines 12-18. Response to Reviewers Description of studies and beams selected for analysis: page 3, lines 16-23, page 27, lines 24-27 and page 28, lines 1-4. Reviewer #2 The paper presents details of four beam specimens tested under four-point bending in order to assess the performance of high-volume fly ash concrete beams with OPC beams. The following technical points may be taken care in the revision. 1) Since the number of test specimens is limited to four, the importance of statistical variation and reliability may pls be included in the description. Response: We are aware of the fact that a statistically representative result cannot be met with only four beam samples made with different concrete types and reinforcement ratios. However, in the case of concrete members in bending, especially lightly reinforced, where reinforcement is governing the flexural behavior, the scatter tends to be small. Having in mind that these results cannot be generalized, an analysis on a database of results from different studies was performed to provide the obtained results a higher level of reliability and representativeness. Unfortunately, a database formed in such a way also had a small number of test results. As you recommended, a comment about reliability is added in the manuscript to emphasize this matter. Notes/actions: Comment is added on page 10, lines 17-18, page 28, lines 4-5; page 32, lines 15-16. 2) The CoV values have been included from the results available in the literature However, since the materials used in the respective study may be varying from that used in the present study, how can one generalize the conclusions? Also pls note the CoV values are large for cracking moment prediction (with max of about 35%). Response: Thank you for your comments and questions, they inspired us to rethink and improve the methodology used in the analysis of results. You are correct. The materials used in analysed studies are different but the aim of this research was not to analyse the material properties of different HVFACs, but to analyse structural behaviour of beams made with concrete of known (tested) compressive strength. The difference in component materials’ amounts and properties influences material properties of concrete, but if we make beams with different concrete mixes and similar/same compressive strength, their structural behaviour can be compared. Besides, same prediction models for SLS and ULS in existing codes for cement concretes are applied for a broad range of their compressive strengths (C12/15-C50/60), meaning that codified models are valid regardless of the concrete mix design - they can be made with different cement types and amounts (sometimes largely different), as long as they fulfil the requirement regarding the compressive strength. The question is of course, if such reasoning is applicable to HVFAC mixes, or at what extent is applicable. For these reasons, after rethinking the parameters defined for the selection of relevant studies, the authors decided to make a narrower selection to have a more coherent set of data and to eventually enable generalization of conclusions for those set of parameters. Defined parameters are described at page 3, lines 21- 25, page 27, lines 24-27 and page 28, lines 1-5. Physical and chemical properties of fly ash are certainly different in the selected studies, but they all conform to a class F. Consequential changes are implemented in Figures 20-23. A comment about limitations of obtained conclusions is added at page 28, lines 4-5 and in conclusions at page 32, lines 15-16. Furthermore, a change in the calculation of cracking moments is made. In order to eliminate the uncertainty of fctm predictions defined in EN1992-1-1 based on concrete compressive strength in the HVFAC case, fctm was calculated as 0.9 times measured splitting tensile strength. In this way all structural parameters were based on measured material properties of used concretes. Unfortunately, this action reduced the number of studies with available data on measured splitting tensile strength. This information was available only in this research and one previously published study. Changes are implemented in Figure 21 and at page 29, lines 13 and 18. After this change, only four results for HVFAC and four for OPC beams were available. CoV for those results is now lower (new Figure 21, page 29), but there are no sufficient data for general conclusions. In previous version of this paper (old Figure 20) a large CoV for cracking moments was observed (35%), as you mentioned. There are several reasons that can explain this. First, those predictions were calculated using fctm that was calculated based on measured compressive strength. Calculation was done using EN1992- 1-1 code prediction defined for traditional cement concretes. In this way, an uncertainty of that equation was also taken into calculation. In revised paper, this was corrected as previously explained. Other reason for cracking moments high CoV is the fact that measuring (capturing) experimental values of the cracking moment is difficult. The first cracking needs to be visually observed during testing or by analysing the load-deflection curve, and it often cannot be done precisely. Therefore, large CoV are also observed for OPC cracking moments. 3) The shear span to depth ratio of the tested specimens may be included in the experimental details. Response: Done as suggested. Notes/actions: Page 3, line 24 and page 28, line 3. 4) Future scope may be included. Response: Future scope is included at page 35, lines 5-9. 5) Use of fly ash normally would increase the workability. Why was then superplasticizer used? Was it the aim to achieve self compacting concrete? Response: Thank you for your comment. Our understanding of this matter is the following. The use of fly ash in concrete influences its workability, but it cannot be generally concluded in what manner due to variety of fly ash physical properties. Particle size distribution of fly ash and the shape of its particles influences concrete workability. If fly ash particles are of a spherical shape (most of them are) they produce a ball-bearing effect and can increase the workability of the mix. If fly ash particles are smaller than cement they can increase particle packaging and also reduce the need for water. However, if fly ash particles are small and the amount of fly ash used in the mix is large, an effect of higher specific surface of fly ash can overcome the previous effects and increase water needed to lubricate fly ash particles. This is in accordance with other researchers findings, for instance http://dx.doi.org/10.1016/j.jobe.2016.09.008 states: Fly ash loses its ability to improve rheological properties of concrete when used in large proportion. The only way to achieve very low water/binder is thus to use superplasticizer hence it became an essential constituent of HVFA concrete. During our preliminary testing (https://doi.org/10.1680/jmacr.15.00384), different workability of concrete was obtained for the same mixtures made with same fly ash sourced in different times. Therefore, the superplasticizer was used to regulate workability without influencing mechanical properties. In the HVFAC mixture selected for this study (200 kg/m3 of cement and 350 kg/m3 of fly ash) with water-to-binder ratio of 0.36, concrete was very dry and unworkable before superplasticizer was added. After the addition of small amount of superplasticizer (2.2 kg/m3) the mixture became very flowable. During trial and error testing of this mixture workability, we didn’t succeed to find the right amount of superplasticizer that would provide adequate workability lower than the one that was shown in this paper. This large amount of fly ash made the mixture stickier and harder to cast, regardless of large flow value. However, during compacting the concrete using vibration, the mixture became more flowable-thixotropy effect was more pronounced than in cement concrete. We finally concluded that this workability was appropriate for quality casting of reinforced concrete beams. 6) Some editorial corrections listed below and similar may be taken care. * Spelling mistake in Fig. 13 may be corrected (Beam length (cm)). * Page 20. Beams with higher tensile reinforcement ratio. The difference between deflection of beams from the 6 second group (Figure 14, right) ………. Is Fig. No. right? Is that Fig. 13? Check. * Casted may be replaced with cast. Response: All corrections have been implemented. Please note that Figure 13 is now Figure 14. You are correct, it was Figure 13, not 14. In the revised version that is Figure 14. Reviewer #3 1) The introduction is poorly prepared. The title and most of the experiments focus on the mechanical properties of HVEAC beams. However, in the current version, five paragraphs are about the HCEAC and its environmental merits. Response: Thank you for your comment. The introduction was indeed focused on environmental and availability aspects of fly ash and its use in concrete. That part is now much shorter, and the state-of-the-art analysis is presented. Notes/actions: SoA: Page 3-lines 17-28; page 4-lines 1-28; page 5, lines 1-11 2) The original scientific contributions of this study are unclear. Response: This work provides a set of experimental data regarding the strength and serviceability of reinforced HVFAC beams produced at full scale and tested until failure. We believe that tests were carefully performed and that results were transparently reported with all necessary data, enabling other researchers to repeat the experiment or to use the results for future investigations. In the analytical part of the work, comparative statistical analysis was used to include already published test results (selected) to widen and strengthen the conclusions. More importantly, this work widens the currently existing experimental data base in the area, which is essential for deriving the codes for design of reinforced concrete structures regardless of the concrete type. Our opinion is that, if we want various types of green concretes to find their application in the real practice, we need more experimental campaigns like this one, and we need them as soon as possible. Notes/actions: The contribution of the study has been highlighted in the introduction at page 5, lines 12-18. Description of studies and beams selected for analysis: page 3, lines 16-23, page 27, lines 24-27 and page 28, lines 1-4. 3) Table 2 and Table 4 should be replaced by two figures. In Table 3, the particle size distributions of the aggregates should be added. Response: Table 2 is showing particle size distribution of the used aggregate. According to your comment, we changed it to Figure 1, page 7. Particle size distribution is not added in Table 3 since it is fully defined in new Figure 1. After considering Table 4 once again, we decided to keep it as a Table. This was done because we wanted to present all data accurately so that other researchers can use it in their studies if needed. If we decided to change it to figure, exact values of compressive strengths wouldn’t be available. We are aware of the fact that compressive strength development of those two concrete types is not visually available now, but if needed for mechanical property assessment, it can easily be transformed into figure by all interested parties. We decided not to add this figure on top of Table 4 to avoid doubling the results. Detailed analysis and graphic presentation of compressive strength development of this HVFAC mixture can be found in previously published paper https://doi.org/10.1680/jmacr.15.00384. Notes/actions: Table 2 is changed with Figure 1 on page 7. 4) For Figures 13-20, and 22, please use (a) and (b) in stead of "right" and "left". Response: Done as requested. Notes/actions: Changes are made in new figures 14-21 and figure 23. 5) Although the test results are clearly presented, they are not deeply discussed. More in-depth discussion should be added. The mechanism should be discussed especially in view of the material composition. For example, lines 20-21 of page 16, why was the flexural tensile strength of HVFAC, cured in the same way as the beams, 24% lower compared with the samples made with OPC concrete mixture? Response: Additional discussions are added to explain the mechanisms in view of the material composition and other influential parameters. Notes/actions: Additional comments added at page 13, lines 12-15; page 14, lines 17-22; page 15, lines 1-4; page 17, lines 20-25. Highlights  Flexural performance of HVFAC beams is similar to flexural performance of corresponding OPC beams in terms of ultimate bending capacity.  Available ultimate bending moments code predictions can be applied on HVFAC beams with similar precision and variation of results, like for OPC beams.  The significant difference was noticed regarding cracking extent that was higher in HVFAC beams, compared with the corresponding OPC beams. Highlights 5 ultimate bending moments for HVFAC and OPC beams, it can be seen that HVFAC beams had up to 1 25% lower capacities. 2 Based on the analysis of previously mentioned studies, it can be concluded that flexural behaviour of 3 HVFAC beams is not fully explained regarding the influence of fly ash amount on ultimate bending 4 capacity, cracking moments, development of flexural cracks, tension stiffening effect, compression 5 softening, short-term and long-term deflection. This small database does not provide enough results for 6 general conclusions and direct guidelines for structural application of HVFAC, especially when 7 considering variability of fly ash physical and chemical properties. HVFAC mixtures have been 8 successfully developed with satisfactory physical and mechanical properties applicable for structural 9 application, but more large-scale experiments are needed to determine the actual feasibility of HVFAC 10 within structural elements [16]. 11 In order to enable practical application of HVFAC in reinforced concrete structures, it is required to 12 produce a code of practice or a standard which regulates the design of such structures. The reliability 13 of prediction models, usually semi-empirical in standards, largely depends on the extent and quality of 14 experimental data bases, as it is the case with cement concrete structures. The main objective of this 15 study is to widen the existing, rather small, experimental data base and to increase the reliability of the 16 future code predictions regarding the ultimate and serviceability limit states of reinforced concrete 17 structures made of HVFAC. 18 Analytical and empirical analysis of traditional cement concrete elements behaviour is defined in 19 different codes and their background documents. The construction industry is using these guidelines to 20 fulfil all requirements for safe construction. Therefore, systematic comparative analysis between OPC 21 concrete and HVFAC was selected as the most suitable methodology. 22 Methods used in this study were experimental and statistical analysis of relevant results. Own 23 experimental research was designed and conducted to generate new data regarding flexural behaviour 24 of two sets of HVFAC beams. Analysis of results was based on own experimental results and selected 25 results from available literature. Application of EN 1992-1-1 [45] code predictions was evaluated on 26 both HVFAC and OPC beams. 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 6 2. Experimental methods 1 In order to do a systematic analysis, the first part of experimental investigation was focused on the 2 selection and testing of component materials and the design and testing of concrete properties. The main 3 part of the experimental method was focused on testing of reinforced concrete beams flexural behaviour. 4 Detailed description of selection and testing of component materials is provided in previously published 5 paper Dragaš et al. [14], and only the main information are presented in the following text. 6 2.1. Component materials and concrete mix design 7 After the analysis of 17 different HVFAC mixtures made with 50–70% of fly ash in SCMs, described 8 in Dragaš et al. [14], the HVFAC mixture with the highest amount of fly ash that can be used in 9 structural applications was selected for this research. The mixture had proper workability and was easily 10 cast, it had adequate 28-day compressive strength (>40 MPa on 100-mm water-cured cube specimens) 11 and suitable 3-day compressive strength for reasons of construction (>12 MPa on 100-mm water-cured 12 cube specimens as 30% of 28-day strength). 13 Basic physical and chemical properties of concrete component materials were tested. Locally available 14 fly ash from the "Nikola Tesla B" power plant in Obrenovac, Serbia was used. This fly ash was produced 15 by the combustion of lignite coal, and it was used in its original form, as collected from a transport line 16 before silo storage. The size distribution of fly ash was tested using Malvern Instruments Mastersizer 17 2000. Fly ash had 10.04% of particles larger than 45 µm, and 50% of particles smaller than 8.5 μm. The 18 density of this fly ash was 2075 kg/m3. The chemical composition of fly ash was determined by X-ray 19 fluorescence analysis and it is shown in Table 1. As can be seen, fly ash met the requirements of EN450- 20 1:2012 [46], and according to ASTM-C618 [47] is classified as low calcium class F fly ash. 21 Table 1. The chemical composition of fly ash and cement 22 Oxides [%*] SiO2 Al2O3 Fe2O3 CaO SO3 Na2O K2O MgO LOI# Fly ash 58.24 20.23 5.33 7.62 2.21 0.52 1.51 2.01 2.19 Cement 21.04 5.33 2.37 60.43 3.55 0.22 0.70 2.43 3.53 * the percentage of oxides within the corresponding material was given by mass (wt%); 23 # LOI – loss on ignition at 1000oC. 24 25 Locally available blended Portland cement CEM II/A-M (S-L) 42.5R was used in the production of 26 both OPC and HVFAC concrete. Composition of this cement is defined as follows: 80–94% of Portland 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 7 cement, 6–20% of granulated slag and limestone and 0–5% of gypsum and mineral fillers. This type of 1 cement was selected as it has been regularly used in the construction practice in Serbia. Chemical 2 properties of cement are shown in Table 1. Cement had 9.14% of particles larger than 45 µm, similar 3 to fly ash, and the density of 3040 kg/m3. 4 Workability of HVFAC mixture was improved using a polycarboxylate ether polymer-based 5 superplasticizer (Glenium ACE, BASF d.o.o.). The density of the superplasticizer was 1070 kg/m3. 6 Aggregates used in concrete preparation were river sand and river coarse aggregate with a 16 mm 7 nominal maximum size. Density of used aggregate was: 2573, 2548, and 2591 kg/m3 for 0/4 mm, 4/8 8 mm and 8/16 mm fractions, respectively. The particle size distribution is given in Figure 1. 9 10 Figure 1. The particle size distribution of aggregate 11 12 Concrete mixtures were designed using the absolute volume method. Laboratory mixer was used for 13 the preparation of concrete mixtures. Total mixing time was approximately 5.0 minutes. Mechanical 14 properties of OPC concrete and HVFAC were tested on different sample shapes and sizes: 100-mm 15 cubes were used for compressive strength testing, 150×150 mm cylinders for splitting tensile strength 16 testing, 120×120×360 mm prisms for flexural tensile strength testing and 150×300 mm cylinders for 17 testing the modulus of elasticity. After mixing, concrete was cast into steel moulds and compacted using 18 a vibrating table. After finishing, the specimens were covered with wet burlap and stored in the 19 laboratory at 20±2°C. They were unmolded after 24 hours and kept in two curing regimes after that: (1) 20 one number of specimens were kept in water until testing and (2) the remaining specimens were kept 21 in laboratory conditions at 20±2°C, the same as beam samples. 22 0 10 20 30 40 50 60 70 80 90 100 0.125 0.250 0.500 1 2 4 8 16 32 Passing (%) Sieve size (mm) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 8 Both concrete mixtures, OPC and HVFAC mixture (C200_F350), were designed to correspond to the 1 same concrete class C30/37 measured at the age of 90 days. This age was chosen because the 2 development of HVFAC concretes’ strength is slower compared with the traditional cement concretes. 3 This is in agreement with the definition of characteristic compressive strength (fck) given in new set of 4 Eurocode standards, where fck can be defined for strength up to 91 days [48]. Concrete mix designs are 5 shown in Table 2. 6 Table 2. Concrete mix design of HVFAC and OPC concrete beams 7 Component materials Agg.* 0/4 (kg/m3) Agg. 4/8 (kg/m3) Agg. 8/16 (kg/m3) Cement (kg/m3) Fly ash (kg/m3) Water (kg/m3) Superplast. ** (kg/m3) OPC 821 547 456 300 0 175 0 C200_F350 624 486 324 200 350 195 2.2 *Agg. – aggregate amount 8 **Superplast. – superplasticizer amount 9 10 2.2. Preparation and casting of beam samples 11 The main part of experimental testing was designed to give comparative results regarding the behaviour 12 under bending of HVFAC and OPC concrete beams. All four beams were simply supported, with a span 13 of 3.0 m, and a total length of 3.5 m. The beams were rectangular in cross-section: 300 mm × 200 mm 14 (height × width). 15 The geometry of the beams, reinforcement layout, concrete component materials, measurement set up 16 and load application were identical in all beams. Two HVFAC and two OPC concrete beams were made 17 with different bending reinforcement. The first comparative pair of beams was made with a minimum 18 tensile reinforcement ratio (0.28%) to analyse extreme ductile behaviour of beams under bending. The 19 second pair was made with tensile reinforcement ratio of 1.46% to test the behaviour under a higher 20 reinforcement ratio more common in practice. In order to ensure flexural failure, adequate shear 21 reinforcement was designed along total beam length. All reinforcement bars were ribbed and B500B 22 type. Adopted notation, longitudinal and shear reinforcement of the beams are shown in Figure 2. The 23 stress–strain relationships for all different reinforcing bars are shown in Figure 3. After placing 24 reinforcement in wooden moulds and placement of concrete, compacting was ensured using a vibrating 25 needle. 26 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 9 1 Figure 2. Beam reinforcement layout (dimensions in cm) 2 3 Moist curing of beams was enabled using wet burlap and a plastic foil. In the first 14 days after casting, 4 beams were sprayed with water to keep the level of moisture in an adequate level. After 14 days the 5 beams were kept in the laboratory at an average temperature of 24.3±2ºC and an average humidity of 6 50.7±5%. 7 8 Figure 3. Stress–strain relationship for reinforcing bars 9 2.3. Test set-up 10 Testing of simply supported beams was done in a four-point bending configuration. This testing set-up 11 generates maximum bending moments in the middle part of beams, almost without shear, and enables 12 measuring maximum strains and deflection in that zone. All beams were tested until failure, by applying 13 force increments of 5, 10 or 20 kN using a hydraulic press. 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 10 Vertical deflection of beams was continuously measured using Linear Variable Displacement 1 Transducers (LVDT) and Mechanical Deflection Gauges (MDGs). The equipment set up is shown in 2 Figure 4. The measuring of concrete strains was done using Vibrating Wire Strain Gauges (VWSGs), 3 and Electric resistance strain gauges (SG) were used to monitor strains in the longitudinal reinforcement 4 (PL-60-11, Tokyo Sokki Kenkyujo Co., Ltd.). 5 Measuring of crack width and propagation was done in two ways: (1) visual measurement was done 6 along the total beam length on both sides of beams and (2) a Digital Image Correlation (DIC) system 7 was used to map flexural cracks in the middle part of one side of all tested beams. Hand measuring was 8 done using plastic crack comparator that measures a crack width of at least 0.03 mm and a magnifying 9 glass. In order to get a better insight of crack distribution in the most affected region, the middle part of 10 beams, Digital Image Correlation System (DIC) was used. In this experimental setup, the part of beams 11 between two loading points (1000 x 300 mm in size) was chosen as a region of interest (Figure 4). 12 13 Figure 4. Measuring equipment setup 14 3. Test results 15 In the following sections, results from testing concretes physical and mechanical properties, and testing 16 of beam elements is shown. Only four samples were tested, so the following results and conclusions are 17 limited to parameters selected in this study. 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 11 3.1. Physical and mechanical properties of concrete 1 Basic physical and mechanical properties needed to ensure HVFAC and OPC concrete characterization 2 and evaluation were tested. Two types of curing regimes were selected. Water curing of samples was 3 chosen as a standard regime for testing concrete mechanical properties and for concrete characterisation 4 according to EN 1992-1-1 [45]. At the same time, reinforced concrete beams were moist cured for the 5 first 14 days, and after that kept in laboratory conditions until testing. Therefore, some concrete samples 6 were cured in the same way as beams to measure mechanical properties needed for evaluation of 7 bending capacity and short-term deflection code predictions. Concrete physical [49–51] and mechanical 8 [52–56] properties were tested according to European Standards. Three samples were made for testing 9 each property. 10 Workability of both concrete mixtures is shown in Figure 5. As can be seen, HVFAC mixture had a 11 very plastic consistency that corresponded to flow class F5 (flow between 560 and 620 mm) according 12 to EN 206-1 [10]. The workability of the OPC mixture corresponded to slump class S3 (100 - 150 mm). 13 No segregation was observed in any of the OPC concrete and HVFAC batches. This difference in 14 workability was a consequence of the superplasticizer used in HVFAC mixture, that was necessary for 15 obtaining a workable mix. 16 17 Figure 5. Slump/flow measurements of concrete mixtures 18 19 The density of fresh concrete mixtures was, on average, 2236.6 kg/m3 (CoV = 3.4%) and 2410.3 kg/m3 20 (CoV = 1.7%) for C200_F350 and OPC mixtures, respectively. The density of hardened concrete 21 mixtures was, on average, 2240.0 kg/m3 (CoV = 1.2%) and 2372.0 kg/m3 (CoV = 2.4%) for C200_F350 22 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 12 and OPC mixtures, respectively. The results of compressive strength, splitting tensile strength, flexural 1 tensile strength and modulus of elasticity tests on concrete samples are shown in Table 3. 2 The difference between HVFAC and OPC concrete 90-day compressive strength was lower than 3% 3 for water-cured samples. As expected, early age concrete strength development was faster for OPC 4 concrete compared to the HVFAC mixture. Even though the 3-day compressive strength of HVFAC 5 was only 64% of the OPC 3-day strength, at the age of 90 days HVFAC exceeded OPC strength 6 development. Besides water curing, concrete samples were made for each tested beam, cured in the 7 same way as beams and tested for compressive strength at the day of beam testing. After 90 days of 8 curing in the same way as beams, OPC concrete samples had approximately 17% higher compressive 9 strength compared with HVFAC samples. Possible reason for this difference may be found in curing 10 conditions. If both OPC and HVFAC samples were cured in water, the same 90-day compressive 11 strength was obtained. However, if samples were cured with less moisture (moist curing for 14 days 12 with wet burlap and plastic foil, after that on air), HVFAC obtained lower compressive strength 13 compared with water cured samples. Several studies showed that similar strength decrease can be 14 noticed between water cured and air cured samples for both OPC and fly ash concrete [57–59], but these 15 studies were conducted with up to 50% of fly ash in total SCM mass. Results presented in [57] show 16 up to 5% higher decrease of compressive strength in HVFAC samples compared with OPC ones, if they 17 are air cured instead of water cured. In order to determine the EN 1992-1-1 strength class, the 18 characteristic value of compressive strength (fck) should be determined based on mean compressive 19 strength (fcm) as fck = fcm –8 MPa. The 90-day mean compressive strengths of water cured samples is 20 52.4 MPa for OPC concrete and 53.5 MPa for HVFAC, as can be seen in Table 3. These results were 21 recalculated from 100-mm cube sample to standard cylinder sample (150×300 mm) by multiplying it 22 with a coefficient of 0.75 [60,61]. In this way, the following characteristic values for OPC and HVFAC 23 compressive strength were obtained: 31.3 MPa and 32.13 MPa, respectively, i.e., both concretes 24 correspond to class C30/37. 25 26 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 13 Table 3. Mechanical properties of HVFAC and OPC concrete 1 Compressive strength, fcm (MPa) Split. tensile str. (MPa) Flex. tensile str. (MPa) Modulus of elasticity (GPa) Curing WC* AC** WC AC AC WC AC Age (days) 3 7 14 28 90 B1 B2 28 90 90 28 90 90 C200_F350 Average 18.8 31.9 39.0 42.0 53.5 47.6 53.1 3.6 2.8 4.9 31.3 33.6 27.6 CoV (%) 3.8 2.8 4.7 14.8 5.5 9.7 1.5 4.6 3.8 1.7 8.7 8.9 4.4 OPC Average 29.5 37.3 42.7 44.7 52.4 58.5 62.4 3.4 2.8 6.4 35.1 39.4 33.0 CoV (%) 6.2 5.5 9.8 8.5 4.8 5.3 1.2 13.7 21.1 6.2 11.7 7.6 2.2 HVFAC/ OPCC 0.64 0.86 0.91 0.94 1.02 0.81 0.85 1.06 1.00 0.77 0.89 0.85 0.84 *WC=water curing, samples cured in water – standard curing 2 **AC=Air curing, samples cured as beam samples 3  Age of testing beams: HVFAC B1=92, B2=87; OPC B1=79, B2=83 4 5 Splitting tensile strength was measured after 28 days of water curing and 90 days of curing in the same 6 way as beams (Table 3). Splitting tensile strength was similar for these two types of concrete for both 7 types of curing regime, with lower variation in HVFAC samples. Flexural tensile strength for samples 8 cured like beams was 24% higher for OPC concrete compared with the HVFAC ones. Modulus of 9 elasticity was measured at 28 and 90 days for samples cured in water, and at 90 days for samples cured 10 like beams. In all cases, modulus of elasticity was 11% to 16% higher in OPC concrete mixture 11 compared with the HVFAC samples. Modulus of elasticity of fly ash particles is generally higher 12 compared with the cement hydration products [62], but OPC mixture in this study has 20% higher 13 content of coarse aggregate compared with the HVFAC one. The difference in modulus of elasticity 14 was governed with higher aggregate content and higher compressive strength of OPC concrete samples. 15 3.2. Reinforced concrete beams’ flexural behaviour 16 Flexural behaviour of beams was evaluated by analysing failure modes, deflection, induced strains and 17 crack development under short-term loading. All beams were tested at the approximate age of 90 days, 18 and the exact age is shown in Table 3. The analysis of beams began by observing the level of applied 19 force that induced the first cracking under bending (2Pcr); the level at which the beams started to express 20 yielding (2Py); the maximum load at failure – ultimate load (2Pu); midpoint beam deflection under 21 service load (aser); midpoint beam deflection at beams’ yielding point (ay); midpoint beam deflection at 22 failure (au); maximum compressive concrete strain at the beams’ midpoint section (εc) and maximum 23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 14 tensile streel strain at the beams’ midpoint section (εs). The service load level was defined as 40% of 1 the ultimate load. All these results for all beams are shown in Table 4. 2 During this analysis, beams’ self-weight and the weight of steel girder used to transfer the load are not 3 considered. These values are considered only during comparison with standard recommendations for 4 design of reinforced concrete structures in the next section of this paper. 5 Table 4. Experimental results of the flexural testing of beams 6 ρ* (%) 2P cr (kN) 2Py (kN) 2Pu (kN) aser (mm) ay (mm) au (mm) εc (‰) εs (‰) OPC–1 beam First group 0.28 20 40 51.3 2.2 11.5 127.5 4.3 51.6 HVFAC–1 beam 15 35 55.1 4.3 17.8 122.0 4.7 66 OPC–2 beam Second group 1.46 30 210 224.1 7.1 22.7 45.2 4.6 5.7 HVFAC–2 beam 20 210 225.3 7.4 23.6 57.6 4.9 21.0 *Longitudinal reinforcement ratio 7 Cracking moment. Due to the load increase, the first flexural cracks appear close to the beams’ 8 midsection. As can be seen from Table 4, the first cracks appeared at lower load level for HVFAC 9 beams for both groups, confirming the flexural tensile strength results in Table 3. Force levels presented 10 in Table 4 are based on visual crack observation. As it is difficult to spot the formation of first cracks 11 by the naked-eye, load-deflection diagrams at the beginning of loading were closely analysed (Figure 12 6). As can be seen, similar load levels indicated formation of first cracks, like spotted during visual 13 crack monitoring. For beams with minimum reinforcement ratio, the first cracks appeared at 39% (OPC- 14 1 beam) and 27% (HVFAC-1 beam) of the ultimate load. The difference was lower for the second group 15 of beams: the first cracks appeared at 13% (OPC-2 beam) and 10% (HVFAC-2 beam) of the ultimate 16 load. The difference in cracking mechanisms in OPC and HVFAC beams can be explained with nature 17 and place of micro cracking in binder paste. In OPC paste crack propagation passes through calcium 18 silicate hydrate and calcium hydroxide, deviating around unhydrated cement particles. The 19 aggregate/mortar matrix is believed to be the site for development of micro cracks [62]. In HVFAC a 20 part of fly ash participates in the pozzolanic reaction, while the other part remains unreacted [63]. 21 Previous research indicated that fly ash particles in HVFAC paste act as a reactive micro aggregates 22 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 21 time of testing for beams with minimal tensile reinforcement ratio and small compressed concrete zone, 1 higher deflection was influenced by 16% lower modulus of elasticity and higher cracking extent of 2 HVFAC-1 beam (see 3.2.1., Figure 11). Deformation of beams with low tensile reinforcement ratios 3 are significantly affected by tensioned concrete between cracks, i.e. tension stiffening effect [68]. 4 Therefore, it can be concluded that tension stiffening effect is less pronounced in HVFAC beam 5 compared with OPC one. 6 Beams with higher tensile reinforcement ratio. The difference between deflection of beams from the 7 second group (Figure 14, b) was 10% for the uncracked state (20% of ultimate load), and within a 5% 8 margin for service and yielding loads. At all load levels, HVFAC-2 beam had higher midpoint 9 deflection, with the highest difference of 12% at the ultimate load level. Lower difference between 10 HVFAC and OPC deflections in beams with higher reinforcement ratio can be explained by two 11 mechanisms: creep and tension stiffening of beams. First, lower creep of HVFAC [14] is more 12 pronounced in beams with higher tensile reinforcement and higher compressed concrete zone. In beams 13 with low reinforcement ratios, tension stiffening effect on deflection of beams is higher compared with 14 beams where high amount of tensile reinforcement overcomes the effect. Therefore, higher cracking 15 extent in HVFAC beams has lower effect in highly reinforced beams. 16 In members with low reinforcement ratios, the deformation capacity of HVFAC members is lower, but 17 it is still sufficient to guarantee enough ductility. In members with higher reinforcement ratios, the 18 behaviour of HVFAC member is very similar to OPC ones, meaning a comparable behaviour and 19 structural application of both can be achieved. 20 3.2.3. Longitudinal reinforcement strains 21 Tension in longitudinal reinforcing bars was measured in the same sections as deflection of beams. 22 Measuring was done using 62 measuring strain gauges glued to each reinforcing bar in five sections 23 along beams length: 15 strain gauges in beams from the first group and 16 strain gauges in beams from 24 the second group (Figure 4). Evaluation of results showed that all strains in one cross section developed 25 in the same way for all measuring points, so their mean values were calculated for each section. The 26 yielding of reinforcement started at the level of measured reinforcing bar yielding strains: 3.1‰ for 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 22 beams from the first group, and 2.8‰ for beams from the second group (Figure 4). Maximum values 1 of reinforcement strains in sections 2-6 at the moment close to failure are shown in Figure 15, and 2 development of strains for all beams is shown in Figure 16. 3 In both groups of beams, three distinct parts of load-strain curves can be seen: (1) linear-elastic 4 relationship until first flexural cracking; (2) decrease of curve slope after cracking but still expressing 5 linear-elastic behaviour; (3) yielding of reinforcement. Until first cracking, reinforcement strains 6 developed equally in OPC and HVFAC beams in both groups of beams. 7 8 Figure 15. Maximal longitudinal strains in reinforcement of a) OPC-1 and HVFAC-1 beams and b) 9 OPC-2 and HVFAC-2 beams 10 11 After first cracks appeared, precise quantitative comparison of reinforcement strains in different beams 12 is impossible, due to great influence of developed cracks. When comparing cracked beams’ 13 reinforcement strains measured using discrete points and strain gauges, it should be kept in mind that 14 the strain values are also influenced by the vicinity of cracks to measuring points. Therefore, parts of 15 beams close to measuring cross section with crack patterns at the point of ultimate loading are shown 16 for each cross section in Figure 16. 17 As can be seen, after first flexural cracks started to appear, yielding of reinforcement was pronounced 18 in sections close to cracks. Due to denser crack patterns in HVFAC beams, more reinforcement yielding 19 and higher strains can be noticed compared with the OPC concrete ones. Even though the longitudinal 20 reinforcement strains developed in the same way for the OPC and HVFAC beams, their maximum 21 values were, on average, 40% higher in HVFAC beams at the moment of failure. 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 23 1 Figure 16. Longitudinal strain development in reinforcement of a) OPC-1 and HVFAC-1 beams and 2 b) OPC-2 and HVFAC-2 beams 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 24 3.2.4. Concrete compressive strains 1 Concrete compressive strains were measured in three sections in the middle part of all beams on both 2 front and back side of the beams at different heights across cross section (Figure 4). Evaluation of 3 obtained results showed that measurements from front and back side of the beams are aligned, so the 4 average value of those measurements were presented in Figure 17. 5 6 Figure 17. Concrete strains in a) OPC-1 and HVFAC-1 beams and b) OPC-2 and HVFAC-2 beams 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 25 Development of concrete strains until the formation of first flexural cracks was the same in OPC 1 concrete and HVFAC beams in both groups. After that point, compressive strains started to increase 2 faster in HVFAC beams compared with the OPC concrete ones. Faster strain increase was noticed in 3 both groups of beams after yielding point: group 1 yielding at 2Py = 40 kN, group 2 yielding point at 4 2Py = 210 kN. Tension strains can be noticed in the lowest row of measuring equipment due to the 5 position of the neutral axis and propagation of flexural cracks. As expected, the highest strains are 6 noticed in midpoint section 4, corresponding to bending moment distribution along beams length. The 7 exact values of maximum strains are shown in Table 4 (εc). As can be seen, compressive strains at failure 8 were higher in HVFAC beams, but the difference was within 10% margin. The difference was also 9 similar in sections 3 and 5. 10 11 3.2.5. Cross section analysis 12 In order to evaluate stiffness of beams, closer look at cross-section strain distribution and curvatures 13 are evaluated. Distribution of strains in midpoint cross-section 4 is plotted for loading steps just before 14 yielding of beams and shown in Figure 18. For both groups of beams, distribution of strains was linear, 15 corresponding to the Bernoulli-Euler hypothesis. Compressed zones of beams were of similar height 16 for OPC concrete and HVFAC beams in both groups. For beams with minimum reinforcement ratio, 17 the height of compressive zone was approximately 65 mm, and for beams in the second group 105 mm 18 and 91 mm for OPC-2 and HVFAC-2 at this load level, respectively. 19 20 Figure 18. Distribution of strains in section 4 for beams from a) the first group and b) the second group 21 In order to take another look at stiffness of beams, moment-curvature relation is calculated based on 22 measured strains in concrete and reinforcement in the mid-point section of beams, and plotted in Figure 23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 26 19. As can be seen, the trend is similar like already shown for load-deflection of beams. It is once again 1 shown that stiffness of HVFAC beam with minimal reinforcement is lower compared with the 2 corresponding OPC one (approximately for 60%). Stiffness of beams with higher reinforcement amount 3 shows no difference. 4 5 Figure 19. Moment - curvature of beams a) from the first group and b) from the second group 6 4. Analysis 7 The analysis in this type of research problem is designed to answer the following question: How is the 8 variation made in the concrete mix design (i.e. high amount of fly ash and low amount of cement) going 9 to influence structural behaviour of reinforced concrete beams? In this work, the chosen methodology 10 is comparative analysis between OPC and HVFAC beams. The analysis will show if there is a difference 11 between HVFAC and OPC behaviour by interpreting own experimental results, and try to see the trend 12 observed in previously published research regarding flexural behaviour of HVFAC beams. The analysis 13 of HVFAC beams under bending was done by comparing the behaviour of OPC and HVFAC beams 14 during experimental testing and by analysing the application of code-based expressions established for 15 OPC on HVFAC beams. During this analysis, the following assumptions were made: (1) all safety 16 factors considering loads and beams’ geometry are taken as equal to one, (2) self-weight of beams and 17 the weight of all equipment parts supported by testing beams are considered, (3) average values of 18 experimentally tested mechanical properties of concrete and steel reinforcement are considered with 19 safety factors equal to one. The first assumption is justified by the fact that the same loading procedure 20 is used for all beams, as well as the casting technique and beam moulds. On the other hand, the last 21 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 27 assumption needs a short analysis to be fully justified. In order to adopt all material safety factors as 1 one, variation of HVFAC compressive strength needs to be similar to adopted compressive strength 2 variation of OPC concrete. A typical value for variation of compressive strength can be taken as 15% 3 [69]. 4 In order to analyse variations in this particular set of conditions, results from tested OPC and HVFAC 5 compressive strengths were analysed. Over the period of four years, 407 different shape samples were 6 tested at different ages. Even though all samples were made at the Laboratory for Materials and 7 Structures at the Faculty of Civil Engineering of Belgrade using the same cement type and fly ash 8 (obtained at different times during the period of four years), a variety of input parameters was present: 9 component materials were of different origin for different batches; mixing was done in different 10 concrete mixers using different procedures; concretes were made with different component material 11 contents; different superplasticizers were used in different quantities; different curing regimes were 12 used (water curing and air curing); testing was performed by different lab technicians. Compressive 13 strength results were always obtained using three or more samples. Variation of strength was 14 determined for HVFAC samples using CoV calculated for each group of samples prepared from the 15 same mix design, cured in the same way and tested at the same age, but not necessarily made from the 16 same batch and at the same time. For all groups of results in 407 tested samples, minimum group CoV 17 was 0.1%, maximum was 20.3%, and the average CoV was 6.6%. Only two groups of samples had 18 higher CoV than 15%, and the average value of CoV for all groups was significantly lower than 15%. 19 Therefore, it can be concluded that the variation of HVFAC compressive strength is in the same range 20 as for OPC concrete. The assumption to use material safety factors equal to one for both OPC and 21 HVFAC samples is justified. 22 The analysis of results was conducted with data from this research and five previously published papers 23 [30,31,35,37,38]. Samples selected from those papers were beams with 50% or higher amount of class 24 F fly ash, cylinder compressive strength higher than 15 MPa, and the ones that were described with all 25 necessary data for the conducted analysis. In this way, twelve couple of beams were selected for the 26 comparison between HVFAC and OPC beams flexural behaviour, and eight beams for the analysis of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 28 EN1992-1-1 code predictions. Those beams had spans in the range of 1.3–3.0 m, widths 10–20 cm, 1 heights 15–30 cm, tension reinforcement ratios 0.28%–2.64%, shear-to-span ratios 3.6-6.25 and 2 different compressive strengths (16–48 MPa). The conclusions that are going to be drawn based on the 3 following analysis are limited to the selected set of data. 4 4.1. Cracking and yielding moments 5 Design of reinforced concrete structures is based on cracked concrete sections. Therefore, the cracking 6 moment (Mcr) is one of the first parameters being evaluated during structural analysis. Also, ductility is 7 important for designing adequate behaviour of reinforced concrete elements (beams), and moment when 8 beams start to yield is one of the ways to evaluate beams ductility. A short analysis of cracking and 9 yielding moments in HVFAC beams was conducted based on own experimental results and 10 experimental results found in literature. In all studies, experimental values of cracking moments were 11 chosen at times when first flexural cracks were detected in tested beams. Ratios between HVFAC and 12 OPC cracking moments (McrHVFAC/McrOPC) in relation to longitudinal reinforcement ratio (ρ) are shown 13 in Figure 20a. As can be seen, the average value of 1.06 indicates practically the same cracking moments 14 of HVFAC and OPC beams. However, cracking moment ratio is in a relatively wide range from 0.72 15 to 1.72, with variation of results being 25%. 16 17 Figure 20. a) Cracking moment and b) yielding moment of HVFAC and OPC beams 18 This variation can be attributed with relatively small amount of available data, variety of experimental 19 parameters and reliability of cracking moment detection. Presented results indicate that more detailed 20 analysis is needed to quantify evident influence of fly ash addition on concrete fracture processes 21 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 29 [70,71]. Another parameter that was evaluated is the yielding moment of beams. In this way, difference 1 in HVFAC and OPC beams ductility is evaluated. A small number of studies analysed the ductility of 2 beams by using load-deflection curve measurements to determine the moment of yielding. As can be 3 seen form Figure 20b, no significant difference between corresponding HVFAC and OPC beams 4 behaviour exist. This was expected having in mind that ductile behaviour of beams is mostly influenced 5 by its longitudinal reinforcement. 6 Furthermore, cracking moments were calculated using EN 1992-1-1 predictions as a product of mean 7 axial tensile strength (fctm) and gross modulus of a concrete cross-section. Mean axial tensile strength 8 was calculated by multiplying splitting tensile strength measured at the age of beam testing with 9 coefficient 0.9. Cracking moments were calculated for own results and the results from [35], since no 10 data on measured splitting tensile strengths were available in other studies. The results are shown in 11 Figure 21 for HVFAC and OPC beams. 12 13 Figure 21. Experimental-to-prediction cracking moments of a) OPC and b) HVFAC beams - 14 EN 1992-1-1 15 Although EN 1992-1 prediction model shows better precision and lower variability for HVFAC, no 16 general conclusions can be drawn considering small number of test results. 17 4.2. Ultimate moment 18 For beams predominantly subjected to bending, ultimate capacity is usually defined by the ultimate 19 bending moment (Mu). Ultimate bending moments at critical sections (mid-sections of the beams) are 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 30 evaluated for HVFAC and OPC beams tested in this study and found in the literature. First, the ratio of 1 experimental ultimate bending moments in corresponding HVFAC and OPC beams is calculated for all 2 available results from literature, and shown in Figure 22 as a function of longitudinal reinforcement 3 ratio. These results show that ultimate bending moments of corresponding HVFAC and OPC beams are 4 very similar, with an average value equal to 1.0 and relatively small variation of results (CoV=6.06%). 5 All twelve results are in a range from 0.98 to 1.15. 6 7 Figure 22. Ultimate bending moments of HVFAC and OPC beams 8 Comparison of HVFAC and OPC ultimate bending moments was also done on the level of EN 1992-1- 9 1 code prediction. This was done for own experimental results and studies from literature that provided 10 all details needed for calculation. Ultimate bending moments are calculated using the equilibrium 11 conditions with the following assumptions: concrete stress–strain relation was chosen as parabola– 12 rectangle diagram (maximum concrete strain 3.5‰); reinforcement steel stress–strain relation was 13 chosen as an idealized bi-linear diagram with a horizontal top branch; calculation was done using mean 14 values of concrete compressive strength at the age of beam testing and mean values of reinforcement 15 yielding values obtained by testing. 16 Experimental-to-prediction values for EN 1992-1-1 are shown in Figure 23. Prediction of ultimate 17 bending moments defined in EN 1992-1-1 showed good correlation with experimental values for both 18 HVFAC and OPC beams. Experimental values were up to 16% higher compared with the calculated 19 ones. More importantly, the difference between OPC and HVFAC prediction precision was similar. The 20 average ratio of experimental-to-prediction ultimate bending moment is 18% higher for HVFAC beams, 21 with 7% higher variation. All OPC results are in a range from 0.66 to 1.36, and for HVFAC from 0.75 22 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 37 [23] Dragaš J, Marinković S, Radonjanin V. Prediction models for high-volume fly ash concrete 1 practical application: Mechanical properties and experimental database. Build Mater Struct 2 2021;64:19–43. https://doi.org/10.5937/grmk2101019d. 3 [24] Dinakar P, Kartik Reddy M, Sharma M. Behaviour of self compacting concrete using Portland 4 pozzolana cement with different levels of fly ash. Mater Des 2013;46:609–16. 5 https://doi.org/10.1016/j.matdes.2012.11.015. 6 [25] Jiang LH, Malhotra VM. Reduction in water demand of non-air-entrained concrete 7 incorporating large volumes of fly ash. Cem Concr Res 2000;30:1785–9. 8 https://doi.org/10.1016/S0008-8846(00)00397-5. 9 [26] Bentz DP, Ferraris CF, Galler MA, Hansen AS, Guynn JM. Influence of particle size 10 distributions on yield stress and viscosity of cement-fly ash pastes. Cem Concr Res 11 2012;42:404–9. https://doi.org/10.1016/j.cemconres.2011.11.006. 12 [27] Tošić N, Marinković S, Pecić N, Ignjatović I, Dragaš J. Long-term behaviour of reinforced 13 beams made with natural or recycled aggregate concrete and high-volume fly ash concrete. 14 Constr Build Mater 2018;176. https://doi.org/10.1016/j.conbuildmat.2018.05.002. 15 [28] Carević V, Ignjatović I, Dragaš J. Model for practical carbonation depth prediction for high 16 volume fly ash concrete and recycled aggregate concrete. Constr Build Mater 2019;213:194– 17 208. https://doi.org/10.1016/j.conbuildmat.2019.03.267. 18 [29] Shafiq N. Effects of fly ash on chloride migration in concrete and calculation of cover depth 19 required against the corrosion of embedded steel reinforcement. Struct Concr 2004;5:5–9. 20 https://doi.org/10.1680/stco.5.1.5.37049. 21 [30] Yoo SW, Ryu GS, Choo JF. Evaluation of the effects of high-volume fly ash on the flexural 22 behavior of reinforced concrete beams. Constr Build Mater 2015;93:1132–44. 23 https://doi.org/10.1016/j.conbuildmat.2015.05.021. 24 [31] Joanna PS, Parvati TS, Rooby J, Preetha R. A study on the flexural behavior of sustainable 25 concrete beams with high volume fly ash. Mater Today Proc 2020;33:1149–57. 26 https://doi.org/10.1016/j.matpr.2020.07.343. 27 [32] Gowda P, Aswath M, Muthu K. Experimental investigation on flexure behaviour of fly ash 28 concrete beams. Int J Adv Sci Tech Res 2013;2:184–99. 29 [33] Narendra BK, Mahadeviah TM. Flexural behavior of Reinforced Fly Ash Concrete in 30 Comparison to Reinforced Normal Concrete beams in Terms of Cracking Load and Ultimate 31 Load Carrying Capacity. Int J Eng Adv Technol 2014:37–40. 32 [34] George S. Flexural behaviour of activated fly ash concrete. Int J Eng Sci Technol 33 2011;3:7633–42. 34 [35] Hashmi AF, Shariq M, Baqi A. Flexural performance of high volume fl y ash reinforced 35 concrete beams and slabs. Structures 2020;25:868–80. 36 https://doi.org/10.1016/j.istruc.2020.03.071. 37 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 38 [36] Chinh N Van. Flexural performance of reinforced concrete beams made with locally sourced 1 fly ash. J Sci Technol Civ Eng 2021;15:38–50. 2 [37] Thangaraj R, Thenmozhi R. Industrial and Environmental Application of High Volume Fly 3 Ash in Concrete Production. Nat Environ Pollut Technol 2013;12:315–20. 4 [38] Thangaraj R, Thenmozhi R. Experimental Study on RC Beams Using High Volume Fly Ash. 5 Int J Technol Eng 2016;03:71–85. 6 [39] Arezoumandi M, Ortega C a., Volz JS. Flexural Behavior of High-Volume Fly Ash Concrete 7 Beams. Transp Res Rec J Transp Res Board 2015;2508:22–30. https://doi.org/10.3141/2508- 8 03. 9 [40] Lisantono A, Wigroho HY, Purba RA. Shear Behavior of High-volume Fly Ash Concrete as 10 Replacement of Portland Cement in RC Beam. Procedia Eng 2017;171:80–7. 11 https://doi.org/10.1016/j.proeng.2017.01.312. 12 [41] Ortega CA. Shear and fracture behavior of high-volume fly ash reinforced concrete for 13 sustainable construction. Missouri University of science and technology, 2012. 14 [42] Sadati S, Arezoumandi M, Khayat KH, Volz JS. Shear performance of reinforced concrete 15 beams incorporating recycled concrete aggregate and high-volume fly ash. J Clean Prod 16 2016;115:284–93. https://doi.org/10.1016/j.jclepro.2015.12.017. 17 [43] Arezoumandi M, Volz JS. Effect of fly ash replacement level on the shear strength of high- 18 volume fly ash concrete beams. J Clean Prod 2013;59:120–30. 19 https://doi.org/10.1016/j.jclepro.2013.06.043. 20 [44] Yoo S-W, Choi YC, Choi W. Compression Behavior of Confined Columns with High-Volume 21 Fly Ash Concrete. Adv Mater Sci Eng 2017;2017:11. 22 https://doi.org/http://dx.doi.org/10.1155/2017/8208079. 23 [45] CEN. EN 1992-1-1: Design of concrete structures - Part 1-1: General rules and rules for 24 buildings. Brussels, Belgium: European Committee for Standardization; 2004. 25 [46] CEN. EN 450-1: Fly ash for concrete — Part 1: Definition, specifications and conformity 26 criteria. Brussels: European Committee for Standardization; 2012. 27 [47] ASTM C618. Standard Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan 28 for Use in Concrete. West Conshohocken, Pennsylvania: 2015. 29 [48] Kanstad T, Klausen A, Menga A. Background document to prEN1992-1-1 D7 Rev 7 Annex D: 30 Evaluation of Early-Age and Long-Term Cracking Due to Restraint. 2021. 31 [49] CEN. EN 12350-5: Testing fresh concrete - part 5: Flow test, 2009, p. 11. 32 [50] CEN. EN 12350-2: Testing fresh concrete - Part 2: Slump, 2009, p. 9. 33 [51] CEN. EN 12350-6 Testing fresh concrete - Part 6: Density, 2009, p. 10. 34 [52] CEN. EN 12390-3 Testing hardened concrete - Part 3: Compressive strength of test specimens, 35 2009, p. 19. 36 [53] CEN. EN 12390-6 Testing hardened concrete - Part 6: Tensile splitting strength of test 37 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 39 specimens, 2009, p. 10. 1 [54] CEN. EN 12390-13 Testing hardened concrete - Part 13: Determination of secant modulus of 2 elasticity in compression, 2009, p. 14. 3 [55] CEN. EN 12390-7 Testing hardened concrete - Part 7: Density of hardened concrete, 2009, p. 4 10. 5 [56] CEN. EN 12390-5 Testing hardened concrete - part 5: Flexural strength of test specimens, 6 2009, p. 11. 7 [57] Radević A, Dragaš J, Carević V, Zakić D, Mladenović M. The influence of different curing 8 conditions on cement and high-volume fly ash concrete properties. Ases Int. Congr. Proc., 9 2018, p. 300–9. 10 [58] Bingöl AF, Tohumcu I. Effects of different curing regimes on the compressive strength 11 properties of self compacting concrete incorporating fly ash and silica fume. Mater Des 12 2013;51:12–8. https://doi.org/10.1016/j.matdes.2013.03.106. 13 [59] Srinath BS, Ramesh KV, Patnaikuni CK, Vani VS, M P. Effect of Curing Methods on Fly Ash 14 based Concrete Effect of Curing Methods on Fly Ash based Concrete. OP Conf. Ser. Earth 15 Environ. Sci. 822, IOP Publishing; 2021, p. 012023. https://doi.org/10.1088/1755- 16 1315/822/1/012023. 17 [60] Neville AM. Properties of Concrete. Longman Scientific and Technical; 1981. 18 [61] Zabihi N. Effect of Specimen Size and Shape on Strength of Concrete. Eastern Mediterranean 19 University, Gazimağusa, North Cyprus, 2012. 20 [62] Zhang MH. Microstructure, crack propagation, and mechanical properties of cement pastes 21 containing high volumes of fly ashes. Cem Concr Res 1995;25:1165–78. 22 https://doi.org/10.1016/0008-8846(95)00109-P. 23 [63] Hemalatha T, Ramaswamy A. A review on fly ash characteristics – Towards promoting high 24 volume utilization in developing sustainable concrete. J Clean Prod 2017;147:546–59. 25 [64] Fayyad TM, Lees JM. Experimental investigation of crack propagation and crack branching in 26 lightly reinforced concrete beams using digital image correlation. Eng Fract Mech 27 2017;182:487–505. https://doi.org/10.1016/j.engfracmech.2017.04.051. 28 [65] Hemalatha T, Ramaswamy A. A review on fly ash characteristics – Towards promoting high 29 volume utilization in developing sustainable concrete. J Clean Prod 2017;147:546–59. 30 https://doi.org/10.1016/j.jclepro.2017.01.114. 31 [66] Ramezanianpour AA, Malhotra VM. Effect of curing on the compressive strength, resistance 32 to chloride-ion penetration and porosity of concretes incorporating slag, fly ash or silica fume. 33 Cem Concr Compos 1995;17:125–33. https://doi.org/10.1016/0958-9465(95)00005-W. 34 [67] Mohamed HA. Effect of fly ash and silica fume on compressive strength of self-compacting 35 concrete under different curing conditions. Ain Shams Eng J 2011;2:79–86. 36 https://doi.org/10.1016/j.asej.2011.06.001. 37 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 40 [68] Gribniak V, Kaklauskas G, Bacinskas D. Experimental investigation of shrinkage influence on 1 tension stiffening of RC beams. Proc. Eighth Int. Conf. Creep, Shrinkage Durab. Concr. 2 Concr. Struct., vol. 1, Taylor andFrancis Group; 2008, p. 571–7. 3 [69] Faber MH. Risk and safety in civil engineering (Lectur Notes). Lect Notes, Inst Struct Eng 4 2007:335. https://doi.org/10.3929/ethz-a-004230964. 5 [70] Golewski GL. The influence of microcrack width on the mechanical parameters in concrete 6 with the addition of fly ash : Consideration of technological and ecological benefits. Constr 7 Build Mater 2019;197:849–61. https://doi.org/10.1016/j.conbuildmat.2018.08.157. 8 [71] Golewski GL. Validation of the favorable quantity of fly ash in concrete and analysis of crack 9 propagation and its length – Using the crack tip tracking ( CTT ) method – In the fracture 10 toughness examinations under Mode II , through digital image correlation. Constr Build Mater 11 2021;296:122362. https://doi.org/10.1016/j.conbuildmat.2021.122362. 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 1 Flexural behaviour and ultimate bending capacity of high-volume fly ash 1 reinforced concrete beams 2 3 Jelena Dragaš1, Snežana Marinković¹, Ivan Ignjatović1, Nikola Tošić2, Veljko Koković1 4 ¹ Faculty of Civil Engineering, University of Belgrade, Bulevar kralja Aleksandra 73, 11000, 5 Belgrade, Serbia 6 2 Civil and Environmental Engineering Department, Universitat Politècnica de Catalunya 7 (UPC), Jordi Girona 1-3, 08034, Barcelona, Spain 8 9 Corresponding author: [email protected] 10 11 Keywords: High-volume fly ash concrete, Beams, Ultimate bending capacity, Cracks, 12 Deflection, Strains. 13 14 15 Revised Manuscript (With Changes marked) Click here to view linked References 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 2 1. Introduction 1 It is a well-known fact that concrete is the most widely used construction material in the world. As a 2 consequence, the current application of concrete is responsible for large consumption of energy and 3 natural raw materials, generating great amounts of waste [1] and approximately 10% of total 4 anthropogenic CO2 (induced mostly by cement production) [2]. A reliable and straightforward way to 5 reduce environmental burden of concrete is by partially replacing cement with some type of 6 supplementary cementitious materials (SCMs). This strategy has a high CO2 reduction possibility: by 7 decreasing the clinker ratio to 0.75 worldwide by 2050 (from 0.87 in 2005), 0.88 Gt of CO2 could be 8 avoided [3]. 9 The most commonly used SCMs are granulated blast furnace slag (industrial by-product), fly ash 10 (industrial by-product) and limestone (raw material). However, the available amount of slag and fly ash 11 is relatively scarce, and it depends on the steel industry and energy production technology. Available 12 amounts of fly ash are different from one country to another, with great pressure to abounded coal 13 burning power plants. This is why a great part of current research is dedicated to finding alternative 14 SCMs with larger available quantities around the world, like calcined clay [4–6]. However, current 15 global events (pandemic and conflicts around the world that increased the price of natural gas) slowed 16 down the planned transition from coal to cleaner energy sources. It is even predicted that the demand 17 for coal could hit an all-time high in 2022 due to economic recovery from Covid-19 [7]. Also, some 18 countries already have great quantities of unused fly ash (e.g. China) and coal (e.g. United States), 19 indicating that fly ash is going to be available in the future. 20 Locally, Serbia has large amounts of low-quality fly ash (more than 3 million tons) deposited on more 21 than 1500 hectares of fertile land. This fly ash is used in the cement industry, but only around 3% has 22 been used so far. This represents a major environmental challenge for cities situated close to areas of 23 these landfills. A possible efficient and sustainable solution would be to increase the consumption of 24 this by-product in the local and regional construction industry. 25 Coal burning fly ash has been a part of concrete since 1930s in the production of mass gravity dams to 26 lower the heat of hydration. Ever since, it has been used as a mineral filer in self-compacting concrete 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 3 [8], as a part of blended pozzolanic cement, as a binder in alkali-activated concrete [9], or as a partial 1 replacement of cement in concrete (mostly up to 33%). In recent years, greater amounts are being used 2 as a partial substitution of cement with more than 50% of cement replaced with fly ash in concrete 3 mixtures (high-volume fly ash concrete–HVFAC). This amount of fly ash in total mass of cementitious 4 materials is greater than maximum amount defined by k-value concept in EN 206-1 [10], but it can be 5 used if adequate (equivalent) performance of HVFAC is achieved. This concrete type was used in the 6 construction of several buildings, mostly in concrete for foundations or, in some cases, beams and slabs 7 [11–13]. 8 Numerous studies investigated physical and mechanical properties of HVFAC [14–23], and it can be 9 concluded that HVFAC, in a general manner, has good workability with adequate superplasticizers 10 [24,25], lower bleeding and segregation [26], longer setting time [18,20], less entrained air [20], lover 11 hydration temperature [15], slower strength development, but higher 90-day strengths [14], lower creep 12 and shrinkage [27], lower carbonation resistance [28], higher resistance to chloride ingress [29]. Unlike 13 material properties, only several published studies investigated structural behaviour of HVFAC beams, 14 mostly flexural [30–39] and shear capacity of beams [8,40–43] and compressive behaviour of columns 15 [44]. 16 Available research papers regarding behavior of HVFAC beams under bending are collected for state- 17 of-the-art analysis. The search was conducted using websites: Science Direct, Scopus, Google Scholar, 18 ASCE library, fib-international, ACI Journals and Google. The following key words were used during 19 this search: High-volume fly ash concrete, Fly ash concrete, Flexural behavior, Beams, Flexural 20 performance, Bending. This search yielded ten studies [30–39] investigating flexural behavior of beams 21 made with different amounts of fly ash - between 10% and 60% of fly ash was used in total cementitious 22 materials (CM) mass. Beams had different spans (1.0–3.6 m), widths (10–30 cm), heights (15–46 cm), 23 tension reinforcement ratios (0.28%–3.18%), shear-to-span ratios (2.5-6.25) and different compressive 24 strengths (10–58 MPa). After the initial analysis of collected research study, a selection of the ones 25 relevant for this research was made. Among all tested beams, the ones made with class F fly [45] ash 26 in the amount of 50% or greater were selected for further analysis. The ones that were made with 27 different mineral admixtures and chemical activators were excluded [34,39], as well as the ones made 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 4 with lower amounts of fly ash [32,36]. This yielded six research papers and conforming to selected 1 criteria, with different amount of available data and results presented in those papers. 2 Yoo et al. [30] investigated the flexural behaviour (development of deflection, steel and concrete 3 strains) of 18 beams made with different amounts of class F fly ash in total CM mass: 0%, 35% and 4 50%, different concrete compressive strengths and reinforcement ratios. They concluded that crack, 5 yield and ultimate loads of beams were practically indifferent to the content of fly ash since the 6 structural behaviour of test beams with fly ash replacement ratio of 35% and 50% was similar to the 7 behaviour of ordinary Portland cement (OPC) beams. Joanna et al. [31] investigated the flexural 8 behaviour of eight beams made with 0% and 50% of class F fly ash tested at different ages, after 28 and 9 56 days of curing. They concluded that HVFAC beams had 2% lower ultimate bending capacity 10 compared to OPC beams when tested after 28 days, but 9% higher when tested after 56 days. Both Yoo 11 ae al. and Joanna et al. concluded that the ductility of HVFAC beams was sufficient to prevent brittle 12 failure. Hashmi et al. [35] conducted a research analyzing flexural behavior of slabs and beams made 13 with 0%, 25%, 40% and 60% of fly ash in total CM mass. Sixteen reinforced beams (10x15x180 cm) 14 with a shear-to-span ratio of 6.25 were tested in a four-point bending test. All concrete mixtures were 15 designed to have the same amount of CMs and water-to-binder ratio. This resulted in significantly lower 16 compressive strength for concretes made with different amount of fly ash (up to 40%) compared to OPC 17 beams. The authors concluded that the ultimate bending capacities of beams were up to 60% lower for 18 beams made with fly ash, but this is in part a consequence of great difference in strength. Narendra, and 19 Mahadeviah [33] conducted a research regarding flexural behavior of twelve beams (12x25x255 cm) 20 made with different amounts of fly ash (0%, 20%, 35% and 50%). Beams were made with different 21 compressive strength classes and longitudinal reinforcement ratios. The authors concluded that there 22 were no significant differences in ultimate bending capacity of beams made with different amounts of 23 fly ash, in that range of parameters. No data about fly ash class of chemical composition were presented 24 in this paper. Thangaraj and Thenmozhi [37,38] investigated the flexural behavior of small beams 25 (10x15x150 cm) made with 50-60% of class F fly ash under different confinement levels achieved with 26 vertical stirrups. The authors concluded that confinement had a positive effect on the ductility of beams, 27 but no systematic analysis of ultimate bending capacity was presented. By comparing the presented 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 5 ultimate bending moments for HVFAC and OPC beams, it can be seen that HVFAC beams had up to 1 25% lower capacities. 2 Based on the analysis of previously mentioned studies, it can be concluded that flexural behaviour of 3 HVFAC beams is not fully explained regarding the influence of fly ash amount on ultimate bending 4 capacity, cracking moments, development of flexural cracks, tension stiffening effect, compression 5 softening, short-term and long-term deflection. This small database does not provide enough results for 6 general conclusions and direct guidelines for structural application of HVFAC, especially when 7 considering variability of fly ash physical and chemical properties. HVFAC mixtures have been 8 successfully developed with satisfactory physical and mechanical properties applicable for structural 9 application, but more large-scale experiments are needed to determine the actual feasibility of HVFAC 10 within structural elements [16]. 11 In order to enable practical application of HVFAC in reinforced concrete structures, it is required to 12 produce a code of practice or a standard which regulates the design of such structures. The reliability 13 of prediction models, usually semi-empirical in standards, largely depends on the extent and quality of 14 experimental data bases, as it is the case with cement concrete structures. The main objective of this 15 study is to widen the existing, rather small, experimental data base and to increase the reliability of the 16 future code predictions regarding the ultimate and serviceability limit states of reinforced concrete 17 structures made of HVFAC. 18 Analytical and empirical analysis of traditional cement concrete elements behaviour is defined in 19 different codes and their background documents. The construction industry is using these guidelines to 20 fulfil all requirements for safe construction. Therefore, systematic comparative analysis between OPC 21 concrete and HVFAC was selected as the most suitable methodology. 22 Methods used in this study were experimental and statistical analysis of relevant results. Own 23 experimental research was designed and conducted to generate new data regarding flexural behaviour 24 of two sets of HVFAC beams. Analysis of results was based on own experimental results and selected 25 results from available literature. Application of EN 1992-1-1 [45] code predictions was evaluated on 26 both HVFAC and OPC beams. 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 6 2. Experimental methods 1 In order to do a systematic analysis, the first part of experimental investigation was focused on the 2 selection and testing of component materials and the design and testing of concrete properties. The main 3 part of the experimental method was focused on testing of reinforced concrete beams flexural behaviour. 4 Detailed description of selection and testing of component materials is provided in previously published 5 paper Dragaš et al. [14], and only the main information are presented in the following text. 6 2.1. Component materials and concrete mix design 7 After the analysis of 17 different HVFAC mixtures made with 50–70% of fly ash in SCMs, described 8 in Dragaš et al. [14], the HVFAC mixture with the highest amount of fly ash that can be used in 9 structural applications was selected for this research. The mixture had proper workability and was easily 10 cast, it had adequate 28-day compressive strength (>40 MPa on 100-mm water-cured cube specimens) 11 and suitable 3-day compressive strength for reasons of construction (>12 MPa on 100-mm water-cured 12 cube specimens as 30% of 28-day strength). 13 Basic physical and chemical properties of concrete component materials were tested. Locally available 14 fly ash from the "Nikola Tesla B" power plant in Obrenovac, Serbia was used. This fly ash was produced 15 by the combustion of lignite coal, and it was used in its original form, as collected from a transport line 16 before silo storage. The size distribution of fly ash was tested using Malvern Instruments Mastersizer 17 2000. Fly ash had 10.04% of particles larger than 45 µm, and 50% of particles smaller than 8.5 μm. The 18 density of this fly ash was 2075 kg/m3. The chemical composition of fly ash was determined by X-ray 19 fluorescence analysis and it is shown in Table 1. As can be seen, fly ash met the requirements of EN450- 20 1:2012 [46], and according to ASTM-C618 [47] is classified as low calcium class F fly ash. 21 Table 1. The chemical composition of fly ash and cement 22 Oxides [%*] SiO2 Al2O3 Fe2O3 CaO SO3 Na2O K2O MgO LOI# Fly ash 58.24 20.23 5.33 7.62 2.21 0.52 1.51 2.01 2.19 Cement 21.04 5.33 2.37 60.43 3.55 0.22 0.70 2.43 3.53 * the percentage of oxides within the corresponding material was given by mass (wt%); 23 # LOI – loss on ignition at 1000oC. 24 25 Locally available blended Portland cement CEM II/A-M (S-L) 42.5R was used in the production of 26 both OPC and HVFAC concrete. Composition of this cement is defined as follows: 80–94% of Portland 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 13 Table 3. Mechanical properties of HVFAC and OPC concrete 1 Compressive strength, fcm (MPa) Split. tensile str. (MPa) Flex. tensile str. (MPa) Modulus of elasticity (GPa) Curing WC* AC** WC AC AC WC AC Age (days) 3 7 14 28 90 B1 B2 28 90 90 28 90 90 C200_F350 Average 18.8 31.9 39.0 42.0 53.5 47.6 53.1 3.6 2.8 4.9 31.3 33.6 27.6 CoV (%) 3.8 2.8 4.7 14.8 5.5 9.7 1.5 4.6 3.8 1.7 8.7 8.9 4.4 OPC Average 29.5 37.3 42.7 44.7 52.4 58.5 62.4 3.4 2.8 6.4 35.1 39.4 33.0 CoV (%) 6.2 5.5 9.8 8.5 4.8 5.3 1.2 13.7 21.1 6.2 11.7 7.6 2.2 HVFAC/ OPCC 0.64 0.86 0.91 0.94 1.02 0.81 0.85 1.06 1.00 0.77 0.89 0.85 0.84 *WC=water curing, samples cured in water – standard curing 2 **AC=Air curing, samples cured as beam samples 3  Age of testing beams: HVFAC B1=92, B2=87; OPC B1=79, B2=83 4 5 Splitting tensile strength was measured after 28 days of water curing and 90 days of curing in the same 6 way as beams (Table 3). Splitting tensile strength was similar for these two types of concrete for both 7 types of curing regime, with lower variation in HVFAC samples. Flexural tensile strength for samples 8 cured like beams was 24% higher for OPC concrete compared with the HVFAC ones. Modulus of 9 elasticity was measured at 28 and 90 days for samples cured in water, and at 90 days for samples cured 10 like beams. In all cases, modulus of elasticity was 11% to 16% higher in OPC concrete mixture 11 compared with the HVFAC samples. Modulus of elasticity of fly ash particles is generally higher 12 compared with the cement hydration products [62], but OPC mixture in this study has 20% higher 13 content of coarse aggregate compared with the HVFAC one. The difference in modulus of elasticity 14 was governed with higher aggregate content and higher compressive strength of OPC concrete samples. 15 3.2. Reinforced concrete beams’ flexural behaviour 16 Flexural behaviour of beams was evaluated by analysing failure modes, deflection, induced strains and 17 crack development under short-term loading. All beams were tested at the approximate age of 90 days, 18 and the exact age is shown in Table 3. The analysis of beams began by observing the level of applied 19 force that induced the first cracking under bending (2Pcr); the level at which the beams started to express 20 yielding (2Py); the maximum load at failure – ultimate load (2Pu); midpoint beam deflection under 21 service load (aser); midpoint beam deflection at beams’ yielding point (ay); midpoint beam deflection at 22 failure (au); maximum compressive concrete strain at the beams’ midpoint section (εc) and maximum 23 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 14 tensile streel strain at the beams’ midpoint section (εs). The service load level was defined as 40% of 1 the ultimate load. All these results for all beams are shown in Table 4. 2 During this analysis, beams’ self-weight and the weight of steel girder used to transfer the load are not 3 considered. These values are considered only during comparison with standard recommendations for 4 design of reinforced concrete structures in the next section of this paper. 5 Table 4. Experimental results of the flexural testing of beams 6 ρ* (%) 2P cr (kN) 2Py (kN) 2Pu (kN) aser (mm) ay (mm) au (mm) εc (‰) εs (‰) OPC–1 beam First group 0.28 20 40 51.3 2.2 11.5 127.5 4.3 51.6 HVFAC–1 beam 15 35 55.1 4.3 17.8 122.0 4.7 66 OPC–2 beam Second group 1.46 30 210 224.1 7.1 22.7 45.2 4.6 5.7 HVFAC–2 beam 20 210 225.3 7.4 23.6 57.6 4.9 21.0 *Longitudinal reinforcement ratio 7 Cracking moment. Due to the load increase, the first flexural cracks appear close to the beams’ 8 midsection. As can be seen from Table 4, the first cracks appeared at lower load level for HVFAC 9 beams for both groups, confirming the flexural tensile strength results in Table 3. Force levels presented 10 in Table 4 are based on visual crack observation. As it is difficult to spot the formation of first cracks 11 by the naked-eye, load-deflection diagrams at the beginning of loading were closely analysed (Figure 12 6). As can be seen, similar load levels indicated formation of first cracks, like spotted during visual 13 crack monitoring. For beams with minimum reinforcement ratio, the first cracks appeared at 39% (OPC- 14 1 beam) and 27% (HVFAC-1 beam) of the ultimate load. The difference was lower for the second group 15 of beams: the first cracks appeared at 13% (OPC-2 beam) and 10% (HVFAC-2 beam) of the ultimate 16 load. The difference in cracking mechanisms in OPC and HVFAC beams can be explained with nature 17 and place of micro cracking in binder paste. In OPC paste crack propagation passes through calcium 18 silicate hydrate and calcium hydroxide, deviating around unhydrated cement particles. The 19 aggregate/mortar matrix is believed to be the site for development of micro cracks [62]. In HVFAC a 20 part of fly ash participates in the pozzolanic reaction, while the other part remains unreacted [63]. 21 Previous research indicated that fly ash particles in HVFAC paste act as a reactive micro aggregates 22 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 15 embedded in hydration products, and generate cracks propagating around these fly ash particles due to 1 weaker bond between fly ash particles and the matrix of hydration products and concentration of 2 stresses. Higher internal micro cracking of HVFAC compared with the OPC concretes was detected in 3 stress strain curve of HVFA paste that is less linear than that of a cement paste [62]. 4 Ductility of beams. The level of load that indicated yielding of beams was similar in OPC and HVFAC 5 beams in both groups. As the beam ductility parameter, a ratio between ultimate deflection and yielding 6 deflection was chosen (au/ay). According to these parameters and load-deflection curves shown in Figure 7 6, it can be concluded that no significant difference between OPC and HVFAC beams’ ductility existed. 8 9 Figure 6. Load-deflection curves for tested beams 10 Load-deflection behaviour after yielding. After yielding, with further load increase, existing cracks 11 widened and more flexural cracks continued to form and propagate toward the compressed concrete 12 zone. In both beams from the first group, branching of some flexural cracks at their top occurred after 13 approximately 70% of the ultimate load. This branching could occur due to micro-cracks existing in the 14 zone close to the crack tip [64]. Before first flexural cracking, all beams expressed linear-elastic 15 behaviour. The stiffness of both beams from the first group was similar with the load–deflection curve 16 having the same slope. From that point, and especially after beams’ yielding point, the OPC-1 beam 17 expressed higher stiffness. In the second group of beams, after the first cracks, the stiffness of both 18 beams was reduced but the relationship was kept as linear until the beams yielding point. The stiffness 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 16 of both OPC-2 and HVFAC-2 beams was similar with the load–deflection curves having the same slope 1 upon this point. 2 Failure and ultimate bending moment. Flexural failure of beams from the first group was ductile and 3 occurred after braking of the longitudinal reinforcement and subsequent crushing of concrete in the 4 midpoint section-at the place of maximum compressive strains (Figure 7). Critical flexural cracks in the 5 midpoint section propagated up to compressed reinforcement. The crushed concrete zone was 6 approximately 100 mm in width, and similar in both OPC-1 and HVFAC-1 beams. In the second group 7 of beams, ductile failure occurred after yielding of longitudinal reinforcement and crushing of concrete 8 in the midpoint section. The height of crushed concrete zone was only few centimetres high, but larger 9 compared with the first group of beams. No horizontal cracks along tensile reinforcement were noticed, 10 indicating good bond between both HVFAC and OPC concrete and reinforcement. The difference 11 between OPC and HVFAC beams ultimate bending capacity was within a 7% margin in both groups. 12 13 Figure 7. Back side of a) OPC-1, b) HVFAC-1, c) OPC-2 and d) HVFAC-2 beams after failure 14 15 3.2.1. Flexural cracks 16 Vertical concrete cracks, caused by the bending of the beams, influence the beams’ stiffness and 17 deflection. Quantification of concrete cracks was done using visual inspection and ruler for mapping 18 cracks on the entire beams length and a DIC system to map cracks in the middle part in more detail. 19 First, the following parameters were chosen for flexural crack pattern comparison of beams: maximum 20 vertical crack length at service load (lser) and ultimate load (lu), number of flexural cracks at service load 21 (nser) and ultimate load (nu), average spacing between cracks at service load (sser) and ultimate load (su), 22 and maximum crack width at service load (wser). Measured values for all beams are shown in Table 5. 23 At service load in both groups, higher number of cracks developed in HVFAC beams (60% for the first 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 17 group and 30% for the second group), and they had higher maximum length (≈60% for the first group 1 and ≈30% for the second group). 2 Crack patterns are shown in Figures 8 and 9, for four load levels: 40% (the service load), 60%, 80% 3 and 100% of the ultimate load. As can be seen, denser crack pattern developed in both HVFAC beams. 4 Also, branching of cracks at the top point can be noticed in beams from the first group. This 5 phenomenon is especially visible in DIC crack patterns, shown for the middle beam section in Figure 6 10. In OPC concrete beams, most of flexural cracks developed as vertical cracks without side branching, 7 except at the crack tip close to ultimate loading. However, crack side branching developed in HVFAC 8 beams throughout the entire crack length starting from the service load level. In the beams tension zone, 9 adjacent cracks merged into net different from OPC concrete beams. Crack spacing corresponded well 10 to the spacing of stirrups in both group of beams. 11 Table 5. Flexural cracks description parameters 12 Beam notation Serviceability state Ultimate state lser, max (mm) nser (-) sser, avg (mm) wser (mm) lu, max (mm) nu (-) su, avg (mm) OPC-1 90 4 178 0.08 290 16 134 HVFAC-1 210 10 151 0.03 269 18 128 OPC-2 154 20 95 0.05 216 29 89 HVFAC-2 228 31 72 0.08 252 40 74 13 In order to quantify the difference between OPC concrete and HVFAC beams crack development, the 14 sum of all crack widths at different load levels was analysed (Figure 11). As can be seen from Figure 15 11, the sum of all crack widths in HVFAC-1 beam was 2.8 times higher compared with the 16 corresponding OPC beam. The HVFAC-2 beam had twice the sum of all cracks compared with the 17 OPC-2 beam. This difference is partially influenced by the difference in flexural tensile strength of 18 these two types of concrete. Flexural tensile strength of HVFAC, cured in the same way as beams, was 19 24% lower compared with samples made with OPC concrete mixture. When fly ash as a SCM is added 20 to binder, the importance of curing conditions becomes even more important compared with OPC 21 concretes [65]. In concretes with composite binders, made with cement and fly ash, curing conditions 22 have higher effect on mechanical properties of concrete since adequate water and temperature demands 23 are now needed for both hydration and pozzolanic reaction. Lack of humidity in HVFAC can reduce its 24 mechanical properties in higher extent compared with the OPC concrete [58,66,67]. Maximum crack 25 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 18 widths at the serviceability state (wser in Table 5) for all four beams were lower than maximum crack 1 widths for all exposure classes defined in EN 1992-1-1. 2 The analysis of cracks length (in the middle part of the beams) showed similar trend of linear increase 3 in both beams from the first group, with higher maximum length in HVFAC beam. In the second group 4 of beams, similar trend of crack length development was noticed, with higher values in HVFAC beams 5 (Figure 12). Having in mind the previous analysis, it can be concluded that crack patterns developed in 6 higher extent in HVFAC beams compared with the OPC ones, especially for beams with minimal 7 reinforcement. 8 9 Figure 8. Flexural cracks on OPC-1 (left) and HVFAC-1 (right) beams 10 11 Figure 9. Flexural cracks on OPC-2 (left) and HVFAC-2 (right) beams – visual method 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 19 Figure 10. Flexural cracks in the middle part of a) OPC-1, b) HVFAC-1, c) OPC-2 and c) HVFAC-2 1 beams – DIC method 2 3 Figure 11. Sum of all cracks widths 4 5 6 Figure 12. Maximum crack length in the middle part of beams from the first group (left) and from the 7 second group (right) 8 9 3.2.2. Deflection of beams 10 Maximum mid-span deflections at the service load level, at yielding and at the ultimate load are shown 11 in Figure 13. Evolution of beams deflection is shown in Figure 14 at three loading levels: 20%, 40% 12 (service load) and 60% of the ultimate load. Measured values generally correspond to a short-term 13 deflection, considering that it is being measured only several hours after self-weight was activated and 14 additional load applied. This deflection is mostly influenced by beams stiffness (modulus of elasticity 15 and geometrical characteristics) and tension stiffening of cracked concrete, but it is in some extent also 16 influenced by concrete creep and shrinkage. Beams are tested at the age of 90 days, and it can be 17 assumed that a great part of shrinkage already took place. Concrete shrinkage was not measured during 18 this experiment, and its’ influence on deflection was not taken into account considering that deflection 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 20 measurement started at the moment when beams were put on supports. Therefore, it can be concluded 1 that the effect of shrinkage on measured deflection can be neglected. However, the effect of concrete 2 creep on beams deflection is, in some extent, present in measured deflection values. The influence of 3 creep on the development of deflection in several hours needed to test beams is included in measured 4 values. 5 Beams with minimal tensile reinforcement ratio. In the first group of beams, deflection of beams at 6 20% of the ultimate loading was approximately 30% higher in HVFAC-1 beam, as can be seen in Figure 7 14a. At this point, no flexural cracks appeared in neither of beams and the absolute deflection level was 8 relatively small (less than one mm). This difference is in accordance with lower modulus of elasticity 9 in HVFAC. 10 11 Figure 13. Midpoint beam deflection at different load levels 12 13 Figure 14. Deflection of beams of a) OPC-1 and HVFAC-1 and b) OPC-2 and HVFAC-2 14 With further load increase and flexural cracking, difference between HVFAC and OPC deflection 15 increased to 50% at the point of service loading. Aside from modulus of elasticity, cracked beams’ 16 deflection is also influenced by its cracking extent. Having in mind low influence of creep at this short 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 21 time of testing for beams with minimal tensile reinforcement ratio and small compressed concrete zone, 1 higher deflection was influenced by 16% lower modulus of elasticity and higher cracking extent of 2 HVFAC-1 beam (see 3.2.1., Figure 11). Deformation of beams with low tensile reinforcement ratios 3 are significantly affected by tensioned concrete between cracks, i.e. tension stiffening effect [68]. 4 Therefore, it can be concluded that tension stiffening effect is less pronounced in HVFAC beam 5 compared with OPC one. 6 Beams with higher tensile reinforcement ratio. The difference between deflection of beams from the 7 second group (Figure 14, b) was 10% for the uncracked state (20% of ultimate load), and within a 5% 8 margin for service and yielding loads. At all load levels, HVFAC-2 beam had higher midpoint 9 deflection, with the highest difference of 12% at the ultimate load level. Lower difference between 10 HVFAC and OPC deflections in beams with higher reinforcement ratio can be explained by two 11 mechanisms: creep and tension stiffening of beams. First, lower creep of HVFAC [14] is more 12 pronounced in beams with higher tensile reinforcement and higher compressed concrete zone. In beams 13 with low reinforcement ratios, tension stiffening effect on deflection of beams is higher compared with 14 beams where high amount of tensile reinforcement overcomes the effect. Therefore, higher cracking 15 extent in HVFAC beams has lower effect in highly reinforced beams. 16 In members with low reinforcement ratios, the deformation capacity of HVFAC members is lower, but 17 it is still sufficient to guarantee enough ductility. In members with higher reinforcement ratios, the 18 behaviour of HVFAC member is very similar to OPC ones, meaning a comparable behaviour and 19 structural application of both can be achieved. 20 3.2.3. Longitudinal reinforcement strains 21 Tension in longitudinal reinforcing bars was measured in the same sections as deflection of beams. 22 Measuring was done using 62 measuring strain gauges glued to each reinforcing bar in five sections 23 along beams length: 15 strain gauges in beams from the first group and 16 strain gauges in beams from 24 the second group (Figure 4). Evaluation of results showed that all strains in one cross section developed 25 in the same way for all measuring points, so their mean values were calculated for each section. The 26 yielding of reinforcement started at the level of measured reinforcing bar yielding strains: 3.1‰ for 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 22 beams from the first group, and 2.8‰ for beams from the second group (Figure 4). Maximum values 1 of reinforcement strains in sections 2-6 at the moment close to failure are shown in Figure 15, and 2 development of strains for all beams is shown in Figure 16. 3 In both groups of beams, three distinct parts of load-strain curves can be seen: (1) linear-elastic 4 relationship until first flexural cracking; (2) decrease of curve slope after cracking but still expressing 5 linear-elastic behaviour; (3) yielding of reinforcement. Until first cracking, reinforcement strains 6 developed equally in OPC and HVFAC beams in both groups of beams. 7 8 Figure 15. Maximal longitudinal strains in reinforcement of a) OPC-1 and HVFAC-1 beams and b) 9 OPC-2 and HVFAC-2 beams 10 11 After first cracks appeared, precise quantitative comparison of reinforcement strains in different beams 12 is impossible, due to great influence of developed cracks. When comparing cracked beams’ 13 reinforcement strains measured using discrete points and strain gauges, it should be kept in mind that 14 the strain values are also influenced by the vicinity of cracks to measuring points. Therefore, parts of 15 beams close to measuring cross section with crack patterns at the point of ultimate loading are shown 16 for each cross section in Figure 16. 17 As can be seen, after first flexural cracks started to appear, yielding of reinforcement was pronounced 18 in sections close to cracks. Due to denser crack patterns in HVFAC beams, more reinforcement yielding 19 and higher strains can be noticed compared with the OPC concrete ones. Even though the longitudinal 20 reinforcement strains developed in the same way for the OPC and HVFAC beams, their maximum 21 values were, on average, 40% higher in HVFAC beams at the moment of failure. 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 29 [70,71]. Another parameter that was evaluated is the yielding moment of beams. In this way, difference 1 in HVFAC and OPC beams ductility is evaluated. A small number of studies analysed the ductility of 2 beams by using load-deflection curve measurements to determine the moment of yielding. As can be 3 seen form Figure 20b, no significant difference between corresponding HVFAC and OPC beams 4 behaviour exist. This was expected having in mind that ductile behaviour of beams is mostly influenced 5 by its longitudinal reinforcement. 6 Furthermore, cracking moments were calculated using EN 1992-1-1 predictions as a product of mean 7 axial tensile strength (fctm) and gross modulus of a concrete cross-section. Mean axial tensile strength 8 was calculated by multiplying splitting tensile strength measured at the age of beam testing with 9 coefficient 0.9. Cracking moments were calculated for own results and the results from [35], since no 10 data on measured splitting tensile strengths were available in other studies. The results are shown in 11 Figure 21 for HVFAC and OPC beams. 12 13 Figure 21. Experimental-to-prediction cracking moments of a) OPC and b) HVFAC beams - 14 EN 1992-1-1 15 Although EN 1992-1 prediction model shows better precision and lower variability for HVFAC, no 16 general conclusions can be drawn considering small number of test results. 17 4.2. Ultimate moment 18 For beams predominantly subjected to bending, ultimate capacity is usually defined by the ultimate 19 bending moment (Mu). Ultimate bending moments at critical sections (mid-sections of the beams) are 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 30 evaluated for HVFAC and OPC beams tested in this study and found in the literature. First, the ratio of 1 experimental ultimate bending moments in corresponding HVFAC and OPC beams is calculated for all 2 available results from literature, and shown in Figure 22 as a function of longitudinal reinforcement 3 ratio. These results show that ultimate bending moments of corresponding HVFAC and OPC beams are 4 very similar, with an average value equal to 1.0 and relatively small variation of results (CoV=6.06%). 5 All twelve results are in a range from 0.98 to 1.15. 6 7 Figure 22. Ultimate bending moments of HVFAC and OPC beams 8 Comparison of HVFAC and OPC ultimate bending moments was also done on the level of EN 1992-1- 9 1 code prediction. This was done for own experimental results and studies from literature that provided 10 all details needed for calculation. Ultimate bending moments are calculated using the equilibrium 11 conditions with the following assumptions: concrete stress–strain relation was chosen as parabola– 12 rectangle diagram (maximum concrete strain 3.5‰); reinforcement steel stress–strain relation was 13 chosen as an idealized bi-linear diagram with a horizontal top branch; calculation was done using mean 14 values of concrete compressive strength at the age of beam testing and mean values of reinforcement 15 yielding values obtained by testing. 16 Experimental-to-prediction values for EN 1992-1-1 are shown in Figure 23. Prediction of ultimate 17 bending moments defined in EN 1992-1-1 showed good correlation with experimental values for both 18 HVFAC and OPC beams. Experimental values were up to 16% higher compared with the calculated 19 ones. More importantly, the difference between OPC and HVFAC prediction precision was similar. The 20 average ratio of experimental-to-prediction ultimate bending moment is 18% higher for HVFAC beams, 21 with 7% higher variation. All OPC results are in a range from 0.66 to 1.36, and for HVFAC from 0.75 22 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 31 to 1.45. It can be concluded that both EN 1992-1-1 code prediction can be applied on HVFAC beams 1 with similar precision and variation of results as for OPC beams. Number of analysed results is too 2 small for general conclusions, but high correlation of experimental and calculated results and similar 3 variation are reliable arguments for previously drawn conclusion. 4 5 Figure 23. Experimental-to-prediction ultimate bending moments of a) OPC and b) HVFAC beams - 6 EN 1992-1-1 7 4.3. Short-term deflection 8 Applicability of EN 1992-1-1 bilinear method for predicting deflection on HVFAC beams was 9 evaluated on own experimental results. Short-term deflections were calculated using average 10 experimental values of the following input data, obtained at the day of beam testing: mean value of 11 tested cylinder compressive strength, mean value of tangent modulus of elasticity (equal to 1.05 of mean 12 tested secant modulus of elasticity), mean value of tensile strength (equal to 0.9 of mean tested splitting 13 tensile strength), mean value of reinforcement yielding stress and modulus of elasticity. Short-term 14 deflection was calculated for serviceability stage (approximately 40% of the ultimate loading), for 15 beams from the first group for 2Pser=20 kN, and for beams from the second group 2Pser=80 kN. 16 Deflections calculated using bilinear method are shown in Table 6. 17 Table 6. Calculated and experimental values of maximum short-term deflections 18 Maximum deflection OPC-1 HVFAC-1 OPC-2 HVFAC-2 Calculated deflection (mm) 4.71 4.79 6.17 6.43 Experimental deflection (mm) 2.20 4.30 7.10 7.40 Exp./Calc. Ratio (-) 0.47 0.90 1.15 1.15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 32 For both groups of beams, similar HVFAC and OPC maximum deflections were obtained using EN 1 1992-1-1 predictions. This is expected, having in mind the same splitting tensile strength and small 2 differences in compressive strength and modulus of elasticity of HVFAC and OPC concretes. 3 Obtained differences should be looked at considering different modulus of elasticity, higher cracking 4 of HVFAC beams, different creep and shrinkage of OPC and HVFAC beams, influence of 5 reinforcement ratio and different compressive zone heights. Evaluation of deflection is a very complex 6 task that requires carefully and systematically designed experimental set up for specific conclusions to 7 be made. That was out of the scope of this research, but the idea was to methodologically look at the 8 results and give a better understanding of that problem. 9 5. Conclusions 10 Flexural performance of beams with two longitudinal reinforcement ratios, made with 63% of class F 11 fly ash in the total amount of cementitious materials was evaluated in this research using own 12 experimental results of testing comparative HVFAC and OPC beams, and by comparing these results 13 with available results from literature and EN 1992-1-1 predictions. The following conclusions can be 14 made based on those results, and for set of parameters adopted in this study or selected previously 15 published studies. 16 Reinforced concrete beams’ flexural behaviour 17  In both tested groups, beams expressed ductile behaviour and failed in flexure. Both OPC and 18 HVFAC beams with minimal reinforcement failed after the braking of longitudinal reinforcement 19 and subsequent crushing of concrete in the midpoint section-at the place of maximum compressive 20 strains. Beams made with higher reinforcement ratio both failed after yielding of longitudinal 21 reinforcement and crushing of concrete in the midpoint section. No horizontal cracks along tensile 22 reinforcement were noticed, indicating good bond in both HVFAC and OPC beams. 23  The first flexural cracks developed at lower load level in HVFAC beams compared with the 24 corresponding OPC ones. In the first group of beams, the cracking moment developed at 13% 25 lower load rate compared with the OPC beam. In beams with higher reinforcement ration, this 26 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 33 difference was only 3%. The difference is consistent with lower flexural tensile strength of HVFAC 1 concrete, compared with the OPC one. Analysis of results found in literature indicated similar 2 cracking moments for HVFAC and OPC beams, but the variability of results was relatively high, 3 indicating that actual difference in cracking moments exist. 4  The level of load that indicated yielding of beams was similar in OPC and HVFAC beams in both 5 groups of tested beams. The same trend was observed in other experimental research found in 6 literature, indicating similar ductility of HVFAC and OPC beams. 7  The difference between OPC and HVFAC beams ultimate bending moment was within a 7% 8 margin in both groups of tested beams. The same trend was observed in other experimental 9 research found in literature. 10  Flexural crack patterns developed at higher extent in HVFAC beams compared with the OPC ones. 11 In HVFAC beams with minimal reinforcement, at the level of up to 60% of ultimate load, 60% 12 higher number of cracks was noticed with 64% higher crack widths and 60% higher lengths. In 13 HVFAC beams with higher reinforcement, at the level of up to 60% of ultimate load, 30% higher 14 number of cracks was noticed with 56% higher crack widths and 30% higher lengths. 15  In HVFAC beams with minimal reinforcement ratio, up to 50% higher service load deflection was 16 measured in HVFAC beam compared with the OPC one. The difference between service load 17 deflection of beams from the second group was within 5% margin. Having in mind that the 18 deflection of beams with minimal reinforcement is strongly affected by tensioned concrete between 19 cracks, unlike in beams with higher reinforcement ratios, it can be concluded that tension stiffening 20 effect is less pronounced in HVFAC beam compared with OPC one. This effect needs more results 21 and analysis to be fully understood. 22  The longitudinal reinforcement strains developed in the same way for the OPC and HVFAC beams, 23 but their maximum values were, on average, 40% higher in HVFAC beams at the moment of 24 failure. This is primarily the consequence of higher cracking extent in HVFAC beams that 25 influenced discrete measuring of strains. 26 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 34  The concrete strains developed in a similar way in both groups of beams with having, on average, 1 7% higher maximum strains in the HVFAC beams compared with corresponding OPC ones. 2  Cross-section analysis showed that the compressed zones of beams were of similar height for OPC 3 concrete and HVFAC beams in both groups. Moment-curvature diagrams showed that stiffness of 4 HVFAC beam with minimal reinforcement was lower compared with the corresponding OPC one 5 (approximately for 60%). Stiffness of beams with higher reinforcement amount showed no 6 difference. 7 Code predictions 8  The application of cracking moment code prediction (EN 1992-1-1) showed 23% higher 9 overestimation for OPC beams compared with HVFAC ones, and higher variation in results in 10 OPC beams. However, no general conclusions can be drawn considering small number of test 11 results. 12  The results of ultimate bending moment code prediction (EN 1992-1-1) analysis showed that 13 calculated ultimate bending moments of corresponding HVFAC and OPC beams are very similar. 14 The average ratio of experimental-to-prediction ultimate bending moment is 6% higher for 15 HVFAC beams, with the same difference in variation. 16  It can be concluded that EN 1992-1-1 bilinear short-term deflection can be calculated with the 17 same precision, or with lower overestimation for OPC and HVFAC beams tested during this study. 18 In conclusion, according to this research, the flexural performance of HVFAC is similar to flexural 19 performance of corresponding OPC beams in terms of ultimate bending capacity. The significant 20 difference was noticed regarding cracking extent that was higher in HVFAC beams. Available ultimate 21 bending moments code predictions can be applied on HVFAC beams with similar precision and 22 variation of results, like for OPC beams. However, this cannot be concluded for parameters depending 23 on the cracking behaviour, like cracking moments or deflections. 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 35 Results and analysis presented in this study indicate that HVFAC can be used in structural elements 1 subjected dominantly to bending, like beams and slabs. More research regarding structural behavior of 2 HVFAC using full-scale long-term tests is needed to develop larger database for reliability analysis. 3 Future scope 4 Based on the conduced state-of-the-art regarding flexural behaviour of HVFAC beams, the following 5 topics and parameters need to be researched more in the future: flexural behaviour of beams with 6 different spans, cross section dimensions, longitudinal reinforcement ratios (especially a minimal ones), 7 behaviour of continuous beam (redistribution of moments, capacity for rotation), cracking development 8 and tension stiffening, long-term behaviour of beams. 9 Funding 10 This work was supported by the Ministry for Education, Science and Technology, Republic of Serbia 11 [grant number TR36017]. 12 References 13 [1] Oikonomou ND. Recycled concrete aggregates. Cem Concr Compos 2005;27:315–8. 14 https://doi.org/10.1016/j.cemconcomp.2004.02.020. 15 [2] UN Environment, Scrivener K, John V, Gartner E. Eco-efficient cements: Potential 16 economically viable solutions for a low-CO2 cement-based materials industry. Cem Concr Res 17 2018;114:2–26. https://doi.org/10.1016/j.cemconres.2018.03.015. 18 [3] Carstensen K, Rapf O. A blueprint for a climate friendly cement industry. 2008. 19 [4] Miller SA, John VM, Pacca SA, Horvath A. Cement and Concrete Research Carbon dioxide 20 reduction potential in the global cement industry by 2050. Cem Concr Res 2018;114:115–24. 21 https://doi.org/10.1016/j.cemconres.2017.08.026. 22 [5] Miller S, Horvath A, Monteiro P. Readily implementable techniques can cut annual CO2 23 emissions from the production of concrete by over 20%. Environ Res Lett 2016;11. 24 https://doi.org/10.1088/1748-9326/11/7/074029. 25 [6] Scrivener K, Martirena F, Bishnoi S, Maity S. Calcined clay limestone cements (LC3). Cem 26 Concr Res 2018;114:49–56. https://doi.org/10.1016/j.cemconres.2017.08.017. 27 [7] Ambrose J. Global demand for coal could hit all-time high in 2022. Guard 2021. 28 [8] Alghazali HH, Myers JJ. Shear behavior of full-scale high volume fly ash-self consolidating 29 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 36 concrete (HVFA-SCC) beams. Constr Build Mater 2017;157:161–71. 1 https://doi.org/10.1016/j.conbuildmat.2017.09.061. 2 [9] Yacob NS, ElGawady MA, Sneed LH, Said A. Shear strength of fly ash-based geopolymer 3 reinforced concrete beams. Eng Struct 2019;196:109298. 4 https://doi.org/10.1016/j.engstruct.2019.109298. 5 [10] CEN. EN 206-1: Concrete – Part 1: Specification performance, production and conformity. 6 Brussels, Belgium: European Committee for Standardization; 2011. 7 [11] Marinković S, Dragaš J. Fly ash. In: Siddique R, Cachim P, editors. Waste Suppl. Cem. Mater. 8 Concr. Woodhead P, Woodhead Publishing; 2018, p. 637. 9 [12] Hopkins D, Thomas M, Oates D, Girn G, Munro R. York University uses High-Volume Fly 10 Ash Concrete for Green Building. Annu. Conf. Can. Soc. Civ. Eng. - CSCE, 2001, p. 7. 11 [13] Paterse I. Nicola Valley Institute. Merrit, British Columbia. Waterloo, Canada: 2008. 12 [14] Dragaš J, Tošić N, Ignjatović I, Marinković S. Mechanical and time-dependent properties of 13 high-volume fly ash concrete for structural use. Mag Concr Res 2016;68:632–45. 14 https://doi.org/10.1680/jmacr.15.00384. 15 [15] Poon C, Lam L, Wong Y. A study on high strength concrete prepared with large volumes of 16 low calcium fly ash. Cem Concr Res 2000;30:447–55. https://doi.org/10.1016/S0008- 17 8846(99)00271-9. 18 [16] Herath C, Gunasekara C, Law DW, Setunge S. Performance of high volume fly ash concrete 19 incorporating additives: A systematic literature review. Constr Build Mater 2020;258:120606. 20 https://doi.org/10.1016/j.conbuildmat.2020.120606. 21 [17] McCarthy M, Dhir R. Development of high volume fly ash cements for use in concrete 22 construction. Fuel 2005;84:1423–32. https://doi.org/10.1016/j.fuel.2004.08.029. 23 [18] Huang CH, Lin SK, Chang CS, Chen HJ. Mix proportions and mechanical properties of 24 concrete containing very high-volume of Class F fly ash. Constr Build Mater 2013;46:71–8. 25 https://doi.org/10.1016/j.conbuildmat.2013.04.016. 26 [19] Kayali O, Sharfuddin Ahmed M. Assessment of high volume replacement fly ash concrete – 27 Concept of performance index. Constr Build Mater 2013;39:71–6. 28 https://doi.org/10.1016/j.conbuildmat.2012.05.009. 29 [20] Duran-Herrera A, Juarez C, Valdez P, Bentz D. Evaluation of sustainable high-volume fly ash 30 concretes. Cem Concr Compos 2011;33:39–45. 31 [21] Yoon S, Monteiro PJM, Macpheec DE, Glasser FP, Imbabi MS-E. Statistical evaluation of the 32 mechanical properties of high-volume class F fly ash concretes. Constr Build Mater 33 2014;54:431–42. 34 [22] Kuder K, Lehman D, Berman J, Hannesson G, Shogren R. Mechanical properties of self 35 consolidating concrete blended with high volumes of fly ash and slag. Constr Build Mater 36 2012;34:285–95. https://doi.org/10.1016/j.conbuildmat.2012.02.034. 37 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 37 [23] Dragaš J, Marinković S, Radonjanin V. Prediction models for high-volume fly ash concrete 1 practical application: Mechanical properties and experimental database. Build Mater Struct 2 2021;64:19–43. https://doi.org/10.5937/grmk2101019d. 3 [24] Dinakar P, Kartik Reddy M, Sharma M. Behaviour of self compacting concrete using Portland 4 pozzolana cement with different levels of fly ash. Mater Des 2013;46:609–16. 5 https://doi.org/10.1016/j.matdes.2012.11.015. 6 [25] Jiang LH, Malhotra VM. Reduction in water demand of non-air-entrained concrete 7 incorporating large volumes of fly ash. Cem Concr Res 2000;30:1785–9. 8 https://doi.org/10.1016/S0008-8846(00)00397-5. 9 [26] Bentz DP, Ferraris CF, Galler MA, Hansen AS, Guynn JM. Influence of particle size 10 distributions on yield stress and viscosity of cement-fly ash pastes. Cem Concr Res 11 2012;42:404–9. https://doi.org/10.1016/j.cemconres.2011.11.006. 12 [27] Tošić N, Marinković S, Pecić N, Ignjatović I, Dragaš J. Long-term behaviour of reinforced 13 beams made with natural or recycled aggregate concrete and high-volume fly ash concrete. 14 Constr Build Mater 2018;176. https://doi.org/10.1016/j.conbuildmat.2018.05.002. 15 [28] Carević V, Ignjatović I, Dragaš J. Model for practical carbonation depth prediction for high 16 volume fly ash concrete and recycled aggregate concrete. Constr Build Mater 2019;213:194– 17 208. https://doi.org/10.1016/j.conbuildmat.2019.03.267. 18 [29] Shafiq N. Effects of fly ash on chloride migration in concrete and calculation of cover depth 19 required against the corrosion of embedded steel reinforcement. Struct Concr 2004;5:5–9. 20 https://doi.org/10.1680/stco.5.1.5.37049. 21 [30] Yoo SW, Ryu GS, Choo JF. Evaluation of the effects of high-volume fly ash on the flexural 22 behavior of reinforced concrete beams. Constr Build Mater 2015;93:1132–44. 23 https://doi.org/10.1016/j.conbuildmat.2015.05.021. 24 [31] Joanna PS, Parvati TS, Rooby J, Preetha R. A study on the flexural behavior of sustainable 25 concrete beams with high volume fly ash. Mater Today Proc 2020;33:1149–57. 26 https://doi.org/10.1016/j.matpr.2020.07.343. 27 [32] Gowda P, Aswath M, Muthu K. Experimental investigation on flexure behaviour of fly ash 28 concrete beams. Int J Adv Sci Tech Res 2013;2:184–99. 29 [33] Narendra BK, Mahadeviah TM. Flexural behavior of Reinforced Fly Ash Concrete in 30 Comparison to Reinforced Normal Concrete beams in Terms of Cracking Load and Ultimate 31 Load Carrying Capacity. Int J Eng Adv Technol 2014:37–40. 32 [34] George S. Flexural behaviour of activated fly ash concrete. Int J Eng Sci Technol 33 2011;3:7633–42. 34 [35] Hashmi AF, Shariq M, Baqi A. Flexural performance of high volume fl y ash reinforced 35 concrete beams and slabs. Structures 2020;25:868–80. 36 https://doi.org/10.1016/j.istruc.2020.03.071. 37 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 38 [36] Chinh N Van. Flexural performance of reinforced concrete beams made with locally sourced 1 fly ash. J Sci Technol Civ Eng 2021;15:38–50. 2 [37] Thangaraj R, Thenmozhi R. Industrial and Environmental Application of High Volume Fly 3 Ash in Concrete Production. Nat Environ Pollut Technol 2013;12:315–20. 4 [38] Thangaraj R, Thenmozhi R. Experimental Study on RC Beams Using High Volume Fly Ash. 5 Int J Technol Eng 2016;03:71–85. 6 [39] Arezoumandi M, Ortega C a., Volz JS. Flexural Behavior of High-Volume Fly Ash Concrete 7 Beams. Transp Res Rec J Transp Res Board 2015;2508:22–30. https://doi.org/10.3141/2508- 8 03. 9 [40] Lisantono A, Wigroho HY, Purba RA. Shear Behavior of High-volume Fly Ash Concrete as 10 Replacement of Portland Cement in RC Beam. Procedia Eng 2017;171:80–7. 11 https://doi.org/10.1016/j.proeng.2017.01.312. 12 [41] Ortega CA. Shear and fracture behavior of high-volume fly ash reinforced concrete for 13 sustainable construction. Missouri University of science and technology, 2012. 14 [42] Sadati S, Arezoumandi M, Khayat KH, Volz JS. Shear performance of reinforced concrete 15 beams incorporating recycled concrete aggregate and high-volume fly ash. J Clean Prod 16 2016;115:284–93. https://doi.org/10.1016/j.jclepro.2015.12.017. 17 [43] Arezoumandi M, Volz JS. Effect of fly ash replacement level on the shear strength of high- 18 volume fly ash concrete beams. J Clean Prod 2013;59:120–30. 19 https://doi.org/10.1016/j.jclepro.2013.06.043. 20 [44] Yoo S-W, Choi YC, Choi W. Compression Behavior of Confined Columns with High-Volume 21 Fly Ash Concrete. Adv Mater Sci Eng 2017;2017:11. 22 https://doi.org/http://dx.doi.org/10.1155/2017/8208079. 23 [45] CEN. EN 1992-1-1: Design of concrete structures - Part 1-1: General rules and rules for 24 buildings. Brussels, Belgium: European Committee for Standardization; 2004. 25 [46] CEN. EN 450-1: Fly ash for concrete — Part 1: Definition, specifications and conformity 26 criteria. Brussels: European Committee for Standardization; 2012. 27 [47] ASTM C618. Standard Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan 28 for Use in Concrete. West Conshohocken, Pennsylvania: 2015. 29 [48] Kanstad T, Klausen A, Menga A. Background document to prEN1992-1-1 D7 Rev 7 Annex D: 30 Evaluation of Early-Age and Long-Term Cracking Due to Restraint. 2021. 31 [49] CEN. EN 12350-5: Testing fresh concrete - part 5: Flow test, 2009, p. 11. 32 [50] CEN. EN 12350-2: Testing fresh concrete - Part 2: Slump, 2009, p. 9. 33 [51] CEN. EN 12350-6 Testing fresh concrete - Part 6: Density, 2009, p. 10. 34 [52] CEN. EN 12390-3 Testing hardened concrete - Part 3: Compressive strength of test specimens, 35 2009, p. 19. 36 [53] CEN. EN 12390-6 Testing hardened concrete - Part 6: Tensile splitting strength of test 37 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 Table 5. Flexural cracks description parameters Beam notation Serviceability state Ultimate state lser, max (mm) nser (-) sser, avg (mm) wser (mm) lu, max (mm) nu (-) su, avg (mm) OPC-1 90 4 178 0.08 290 16 134 HVFAC-1 210 10 151 0.03 269 18 128 OPC-2 154 20 95 0.05 216 29 89 HVFAC-2 228 31 72 0.08 252 40 74 Table5 Click here to access/download;Table;Table 5_rev.docx Table 6. Calculated and experimental values of maximum short-term deflections Maximum deflection OPC-1 HVFAC-1 OPC-2 HVFAC-2 Calculated deflection (mm) 4.71 4.79 6.17 6.43 Experimental deflection (mm) 2.20 4.30 7.10 7.40 Exp./Calc. Ratio (-) 0.47 0.90 1.15 1.15 Table6 Click here to access/download;Table;Table 6_rev.docx Figure1 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 1_rev.tif Figure2 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 2_rev.tif Figure3 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 3_rev.tif Figure4 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 4_rev.tif Figure5 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 5_rev.tif Figure6 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 6_rev.tif Figure7 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 7_rev.tif Figure8 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 8_rev.tif Figure15 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 15_rev.tif Figure16 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 16_rev.tif Figure17 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 17_rev.tif Figure18 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 18_rev.tif Figure19 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 19_rev.tif Figure20 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 20_rev.tif Figure21 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 21_rev.tif Figure22 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 22_rev.tif Figure23 Click here to access/download;Figure (Do not upload picture, .svg format. Upload only PDF, eps or tiff format);Figure 23_rev.tif