Full text
Treball de Fi de Màster Màster Universitari en Enginyeria de l’Energia (MUEE) Suitability of STERG’s HelioPod for Azelio’s CSP tower Autor: Marco Bonfanti Director: Ivette Maria Rodriguez Perez Supervisores: Rafael E. Guédez Matti Lubkoll Convocatòria: October 2019 Escola Tècnica Superior d’Enginyeria Industrial de Barcelona
Abstract Azelio is developing a unique distributed solution able to provide dispatchable solar energy by concentrating solar power (CSP) technology. Azelio solution provides a relatively small, modular CSP product using a central receiver setup. There, solar irradiation is concentrated onto the receiver using a heliostat field. Heliostats are the largest capital cost driver of CSP plants and their optical performance is at the same time integral to the plant’s efficiency. Therefore, the heliostats may comply the thermal requirements at competitive cost. The objective of this work is to investigate the potential of adapting the heliostat technology developed at Solar Thermal Energy Research Group (STERG) to suit Azelio’s tower technology and needs. STERG technology raised interest due to an innovative system of six heliostats sharing a common mounting structure. Such a system is referred to as a HelioPod. A study of the optical efficiency of the heliostat fields is conducted to design four dedicated layouts able to reach Azelio heat flow rate requirements with the highest annual energy collection. The development of a performance assessment based on Monte Carlo ray-tracing model provides a high accuracy analysis and points out what is possible to achieve. A Monte Carlo raytracing model was set up to simulate the performance of the heliostat field layouts and analyze the individual heliostat and HelioPod performance. The ray-tracing model was further used to investigate the benefit of utilizing different heliostat focal length to those currently deployed on the HelioPod for the purpose of the Azelio plant. The findings show that a small set of facet focal lengths may provide excellent heliostat imaging accuracy. Finally, a preliminary analysis of the facet surface slope error sets the boundary of the minimum acceptable requirements. This thesis suggests that, as a next step, prototype facets with shorter focal length of 15 m should be designed and manufactured. Keywords: small-scale CSP; heliostat; optical efficiency; ray-tracing model; facet focal lengths. i
Resum Azelio està desenvolupant una solució distribuïda única capaç d’oferir energia solar desencadenable mitjançant la tecnologia de concentració d’energia solar (CSP). La tecnologia Azelio té com a objectiu la producció d’electricitat a petita escala mitjançant camps de heliostat petits. Els heliostats són el major controlador de costos de capital de les plantes CSP i el seu rendiment òptic és alhora integral de l’eficiència de la planta. Per tant, els heliòstats poden complir requisits òptics estrictes a un cost competitiu. L’objectiu d’aquest treball és investigar el potencial d’adaptar el tecnologia d’heliostat desenvolupada al Grup de Recerca d’Energia Solar Tèrmica (STERG) per adaptar-se a les tecnologies i necessitats de la torre d’Azelio. La tecnologia STERG va augmentar l’interès gràcies a un innovador sistema de sis heliostats que compartia una estructura de muntatge comuna. Es coneix com a sistema HelioPod. Es realitza un estudi de l’eficiència òptica dels camps heliostat per dissenyar quatre aparells dedicats capaços d’aconseguir els requisits de flux de calor d’Azelio amb la col·lecció d’energia anual més alta. El desenvolupament d’una avaluació de rendiment basada en el model de traçat de raigs de Monte Carlo proporciona un anàlisi d’alta precisió i assenyala allò que es pot aconseguir. Després, un estudi d’alt nivell es reserva a les pèrdues de vessament per identificar la longitud focal necessària per adaptar-se al receptor Azelio. Els resultats mostren que un petit conjunt de longituds focals de facetes poden proporcionar una excel·lent precisió d’imatge d’heliostat. Finalment, es presenta una anàlisi preliminar de l’error de pendent de la superfície de la faceta per establir el límit dels requisits mínims acceptables. Aquesta tesi proporciona unes directrius clares sobre els passos següents per a la fabricació d’un prototip de facetes. Paraules clau: CSP small-scale; heliostat; eficiència òptica; model ray-tracing; facetes distàncies focals. ii
Contents Abstract i Resum ii Contents vi List of Figures viii List of Tables ix Nomenclature xi Preface 1 1 Introduction 3 1.1 Background ........................................ 4 1.1.1 Overview of Generic Receiver Concepts . . . . . . . . . . . . . . . . . . . . 5 1.1.2 Azelio’sCSPTower................................ 6 1.1.3 Overview of Heliostat Technology . . . . . . . . . . . . . . . . . . . . . . . 7 1.1.4 STERG’sHelioPod ................................ 11 1.2 Objective.......................................... 12 1.3 Methodology ....................................... 12 1.4 Scope............................................ 13 I HelioPod Optical Performance 15 2 Ray-tracing Model 16 2.1 Definition ......................................... 16 2.1.1 Performance Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 2.1.2 Design day and Representative days . . . . . . . . . . . . . . . . . . . . . . 18 2.2 ModelDescription .................................... 19 2.2.1 Sun Shape and Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 2.2.2 Heliostat Field Component . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 2.2.3 Tower Structure Component . . . . . . . . . . . . . . . . . . . . . . . . . . 21 2.3 Post-Processing and Outcomes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 2.4 AccuracyofOutcomes .................................. 23 3 Heliostat Field Layout Design 26 iv
CONTENTS v 3.1 Assumptions........................................ 27 3.2 Procedure ......................................... 27 3.3 OversizedHeliostatField................................. 28 3.3.1 Creation ...................................... 28 3.3.2 Layout and Efficiency Map . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 3.3.3 Analysis ...................................... 31 4 HelioPod Performance Assessment 33 4.1 Heat Flow Rate Capacity of HelioPods . . . . . . . . . . . . . . . . . . . . . . . . . 33 4.2 DecisionMaking ..................................... 34 4.3 Dedicated Heliostat Field Layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 4.4 Sensitivity Analysis on Cavity Aperture Diameter . . . . . . . . . . . . . . . . . . 36 II HelioPod Facet Adaptation 39 5 Focal Lengths Identification 40 5.1 Assumptions........................................ 40 5.2 Current HelioPod’s Facet Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5.3 Incremental Number of Facet Focal Length . . . . . . . . . . . . . . . . . . . . . . 42 5.3.1 OneFocalLength................................. 43 5.3.2 TwoFocalLengths ................................ 43 5.3.3 ThreeFocalLengths ............................... 44 5.4 SummaryofFindings................................... 46 III Future Work and Conclusions 49 6 Future Work 50 6.1 Facet Mechanical Deformation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 6.2 SurfaceQualityAnalysis................................. 51 6.2.1 OneFocalLength................................. 51 6.2.2 TwoFocalLengths ................................ 52 6.2.3 ThreeFocalLengths ............................... 52 6.2.4 SummaryofFindings .............................. 54 7 Conclusions 56 Acknowledgements 58 IV Appendices 60 A Tonatiuh Ray-tracing Model 61 A.1 Validation of Tonatiuh in the literature . . . . . . . . . . . . . . . . . . . . . . . . . 61 A.2 Validation of Tonatiuh Single Heliostat Simulations . . . . . . . . . . . . . . . . . 62 A.3 Tonatiuh Attenuation Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 B Heliostat Field Coordinates Creation in Matlab 64 C Sensitivity Analysis on Cavity Aperture Diameter 66
vi CONTENTS D Suitability of Identified FFL for Smaller Field Layouts 71 Bibliography 74
List of Figures 1.1 Share of the population with access to electricity, 2017 . . . . . . . . . . . . . . . . 3 1.2 Annual Direct Normal Irradiance worldwide . . . . . . . . . . . . . . . . . . . . . 4 1.3 Technology schemes for concentrating solar irradiation. . . . . . . . . . . . . . . . 5 1.4 External and cavity receivers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.5 Rendering of Azelio’s CSP receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1.6 Heliostatcomponents................................... 8 1.7 Tracking mechanism concepts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1.8 Point supported facet by pins and pads . . . . . . . . . . . . . . . . . . . . . . . . 10 1.9 Scheme of sandwich facet assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1.10STERG’sHelioPodsystem ................................ 11 2.1 Optical losses in an CR system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 2.2 Tonatiuh model after a sample simulation with 103rays. .............. 19 2.3 Angle subtended by the sun. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 2.4 Sample of generic HelioPod field layout. . . . . . . . . . . . . . . . . . . . . . . . . 20 2.5 Azelio receiver model in Tonatiuh . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 2.6 Accuracy of outcomes regarding individual heliostat optical efficiency . . . . . . 23 2.7 Accuracy of outcomes regarding field optical efficiency . . . . . . . . . . . . . . . 24 3.1 Heliostat field layouts with radial arrangement. . . . . . . . . . . . . . . . . . . . . 26 3.2 Flow chart of heliostat field layout design’s methodology. . . . . . . . . . . . . . . 27 3.3 First attempt of oversized heliostat field . . . . . . . . . . . . . . . . . . . . . . . . 28 3.4 Layout and performance of oversized heliostat field for design day. . . . . . . . . 29 3.5 Oversized heliostat field performance on summer (a) and winter (b) solstice. . . . 30 3.6 Oversized heliostat field performance on three representative days. . . . . . . . . 30 4.1 Heat flow rate capacity of HelioPods . . . . . . . . . . . . . . . . . . . . . . . . . . 33 4.2 Selection of best performing HelioPods for 200 kWth case............... 34 4.3 Performance assessment of dedicated field layouts . . . . . . . . . . . . . . . . . . 35 4.4 Performance assessment and heat flow rate at design point with smaller cavity diameters. ......................................... 36 5.1 Ideal case’s daily efficiency of 17 HelioPods field layout in the design day. . . . . 40 5.2 Utilization of the current 35 m FFL in 17 HelioPods field layout. . . . . . . . . . . 41 5.3 Utilization of the current 35 m FFL in dedicated field layout. . . . . . . . . . . . . 42 5.4 Focal length identification of 200 kWth field layout with one FFL . . . . . . . . . . 43 5.5 Individual heliostat daily efficiency of 200 kWth field layout with two FFL. . . . . 44 5.6 Identified FFL combinations for 17 HelioPods field layout with three FFL. . . . . 45 vii
Chapter 1 Introduction One billion people around the world are currently lacking access to electricity [1]. In the countries shown in Figure 1.1, people without electricity continue to rely on solid fuels for cooking food and heating [2]. The fire is usually ignited inside homes without proper chimneys, increasing the risk of danger and releasing many pollutants. The United Nations acknowledged the interlinkages between energy, poverty and inequality such as a “vicious circle” in which “a lack of energy access leads to limited income-earning capability, which reduces purchasing power, which in turn limits the access to energy that could improve incomes” [3]. Therefore, the access to electricity may lead to substantially reduce poverty and embrace development [2]. Figure 1.1: Share of the population with access to electricity, 2017 [1]. 3
41.1. BACKGROUND The world map in Figure 1.2 points out that the regions with less access to electricity are also the ones where the sun shines the most. Innovative technology improvements and cost reductions can lead to deliver electricity with affordable solutions from solar resource. Figure 1.2: Annual Direct Normal Irradiance (DNI) worldwide [4]. To date, there are two main technologies to produce electricity from the solar irradiation, namely solar photovoltaics (PV) and concentrating solar power (CSP). The latter receives a dedicated attention in this thesis. 1.1 Background The energy harvesting method of CSP consist of the solar energy being reflected by mirrors and concentrated onto a receiver, where the solar energy is converted into heat at elevated temperature in order to run a thermodynamic cycle and produce electricity. CSP potential is fully exploited when the high-temperature source supplies heat to an intermediate thermal energy storage (TES). CSP has indeed risen great attraction since it can intrinsically produce dispatchable electricity. At cost of an additional investment, the TES integration unlocks the possibility to plan electricity production for both 24/7 and merely period of high demand and electricity prices. Unlike PV electricity production, CSP with TES does not depend on the short-term weather condition and contributes to frequency control in the ancillary services by means of its turbine inertia. Furthermore, while PV power plants provides electricity at a cheaper cost than CSP plants during the sun hours, the solution of PV plus storage of electricity is in general more expensive than CSP with TES. Thus, TES integration makes CSP more suitable for long-term storage. As indicated by the name, the first step for the success of the technology consists of concentrating the solar irradiation from the solar field to a focal point. Figure 1.3 shows the evolution of
CHAPTER 1. INTRODUCTION 5 this basic idea, which brought complexity to the system but increased the temperature at the receiver. The solar central receiver (CR) technology (c), also referred to as solar tower, is obtained by applying the Fresnel lens concept (b) on the parabolic dish (a): the curved parabolic dish is divided into a set of concentric annular sections and then disposed on the field. (a) Parabolic dish. (b) Fresnel lens. (c) Solar central receiver. Figure 1.3: Technology schemes for concentrating solar irradiation. The CR is the CSP technology analyzed in this thesis. In particular, the main focus regards the solar field composed by the sun-tracking mirrors (heliostats) and the receiver. A brief overview of receivers and heliostat technology is given below together with the technologies listed in the thesis’s title, namely Azelio’s CSP tower and STERG’s HelioPod. 1.1.1 Overview of Generic Receiver Concepts The receiver collects and transfers the solar irradiation from the heliostats to a heat transfer fluid (HTF) as efficiently as possible. The heat exchanger, which contains and transfers the heat to the HTF, is referred to as absorber and is a component of the receiver [6]. In the CR plants, the receiver is located at the top of the tower as shown in Figure 1.3c. The tower height impacts the blocking and the shadowing among the heliostats as well as the projected area of the heliostats. In general, two main types of receivers are used: external and cavity receivers. (a) External receiver for direct steam generation. (b) Cavity receiver with four apertures. Figure 1.4: Basic receiver types [5].
61.1. BACKGROUND External receiver The external receiver is the most widely used design for CR plants. The name refers to fact that the absorber tubes are externally mounted around the tower usually in a cylindrical manner as shown in Figure 1.4(a). The absorbers must be sized to contain the size of any image from the heliostats in the field to ensure that the spillage does not damage the receiver structure. However, the heat losses due to convection and radiation are directly proportional to the aperture area, enhanced by the receiver concept itself which exposes an high temperature surface to the ambient. Radiative losses can be minimized by employing high-temperature selective coatings [6]. Cavity receiver On the other hand, the main advantage of cavity receivers is that the heat absorbing surface is encased inside an open or windowed cavity, as shown in Figure 1.4(b), in order to reduce heat losses to the ambient. Therefore, they are preferred for high-temperature applications due to their high absorption efficiency. As an option to further improve the absorption of solar irradiation, a secondary concentrator such as a compound parabolic concentrator (CPC) at the aperture of the receiver and on the cavity walls can focus the incoming rays with a certain efficiency toward the absorber. Beside, the capture of spillage irradiation helps protect the walls of receivers from overheating, thus lowering the requirements for using protective shields and active cooling [6]. 1.1.2 Azelio’s CSP Tower Azelio is a Swedish company "in the game of changing the future of solar energy" [7]. Its mission consists of supplying reliable electricity to off-grid areas by means of its unique cost competitive solution. The unique proposition is given by the combination of a TES system with a Stirling engine, which provides production of electricity from renewable on demand in small scale applications. Azelio has identified a gap in the market for small scale installations (0.1 MW –10 MW) with a long-term storage. The TES is an eutectic alloy of aluminium and silicon, thus a phase change material (PCM), and is designed to cover up to 13 hr of electricity production at nominal power. Azelio has a 25 years experience as specialized supplier of Stirling engines, which efficiently suits small scale installations with an engine easy to install and maintain [8]. Another benefit is that Stirling engine’s working fluid is cooled down by ambient air, thereby not requiring any process water in the power block. Although diesel generators are considered the conventional back-up electricity source in isolated microgrids or unstable grids, Azelio is working for its solution, alone or combined with other renewable sources, to be a low-cost carbon-free replacement in the regions with high DNI [7]. In fact, the TES potential is fully exploited when it is coupled with electrical heaters: the excess or curtailed power can be stored to shift the electricity production in balance with the demand. Figure 1.5 illustrates the Azelio CSP solution, in which both, the TES and the Stirling engine, are located with the receiver. Receiver system is designed by matching thermal requirements of the power block with thermal characteristics of a cavity receiver. Despite coupling the TES with electric heater is an option to extend the solution potential, the heliostat field is the preferable
CHAPTER 1. INTRODUCTION 7 Figure 1.5: Rendering of Azelio’s CSP receiver with both the TES and the power block [7]. supplier of the heat flow rate to the achieve the thermal requirements. Since the physical limitations about reflecting the solar irradiation on the absorber inside the cavity and high flux requirements, Azelio demands for small and accurate heliostats, able to concentrate the projected image onto a narrow area of the absorber, in a compact disposition very close to the tower. Azelio is investigating in some range of nominal heat flow rate for its CSP plants. Table 1.1 lists the nominal heat flow rate and some specification of Azelio’s tower technology, received by personal communication with Azelio. Further details of the receiver model are provided in its dedicated Section 2.2.3. Table 1.1: Specifications of Azelio tower technology and heat flow rate needs. Specification Value Unit Tower height 14 m Cavity opening diameter 0.65 m Nominal heat flow rate at design point 80, 120, 160, 200 kWth The thesis was conceived with certain boundaries. Regarding the receiver system, the analysis of the thesis is limited to the optical performance of the heliostat field and no heat-exchange phenomena are studied. The optical performance is assessed at the absorber surface. 1.1.3 Overview of Heliostat Technology The heliostat is a mechanical driven optical reflector that, unlike other CSP concentrators, is able to continuously track the sun in two axis. The cost of the heliostat field accounts up to 50% of a conventional CR plant, thus their cost reduction without alteration of optical performance is a key point for CSP competition with other renewable technologies and fossil fuels [9]. An overview of the heliostat components and tracking system is preliminary given to introduce the technology.
81.1. BACKGROUND Figure 1.6: Heliostats used in Gemasolar CR power plant, Andalusia, Spain [10]. Heliostat components The components of a conventional heliostat used in large scale power production are illustrated in Figure 1.6. The reflective surface is composed by one or a set of mirrors, called facets, attached to backing structure which is moved by a tracking system controller. The backing structure in the figure consists of a torque tube and perpendicular trusses. Two drives mechanically rotate the backing structure over the torque tube and pylon axis. The control system communicates with the drives to track the sun throughout the year. Tracking mechanism A heliostat typically has two tracking axis with a dedicated drive each. The drives must withstand the wind loads and the momentum of the heliostat structure, while maintaining high pointing accuracy. During high wind events, the heliostat is taken to a so called "stow position" to reduce wind loading. The two most common drive types are slew drives, shown in Figure 1.6, and linear actuators [11]. The orientation of the primary-axis defines the tracking mechanism. The Azimuth Zenith, also referred to as T-Type, has a vertical primary axis while the secondary is horizontal. On the other hand, the Fixed Horizontal mechanism has a horizontal primary-axis. Finally, the Target Aligned type has a primary-axis which points directly the receiver. Figure 1.7 shows a representation of the three concepts. The T-Type is the standard concept among large scale CR plants for the simplicity of its configuration, the Fixed Horizontal allows a denser heliostat field due to a reduced collision potential and the Target Aligned was developed for superior optical properties but with a complex system [11] [12]. The tracking error, σtrack, accounts for the angular deviation of the image from the aim point, thus is measured in mrad.
CHAPTER 1. INTRODUCTION 9 (a) Azimuth Zenith or T-Type [11]. (b) Fixed Horizontal [11]. (c) Target Aligned [12]. Figure 1.7: Tracking mechanism concepts. Heliostat facet Since the purpose of the heliostat is to reflect the solar irradiation, the reflective surface deployed in CSP plants have to ensure the highest reflectivity possible, typically between 90% - 95% [5]. The standard material is thin (1 mm-4 mm) silvered glass mirror due to good optical properties and low outdoor degradation. Silvered polymer film and anodized aluminum with protective coatings are already available alternatives. Polymer mirrors have been also proposed but they have not been accepted by CSP industry yet, thereby further validations and research need to effectively show its potential in replacing glass [13]. The reflective surface has a concave shape to increase the image concentration rather than a flat profile [11] in order to be suitable for CSP high temperature applications. The typical profile is spherical, which is characterized by a radius of curvature. Due to optical principles, the light incident toward the mirror and parallel to the principal axis (line passing through the center of the sphere and attaching to the mirror in the exact center of the mirror) cross the principal axis after reflection in the focal point. The distance of the focal point from the center of the mirror is called focal length. The facet focal length is one of the analyzed variable of the thesis. The curved profile introduces a level of complexity in manufacturing the mirror which may provoke shape deformations [14]. The surface slope error (SSE), σSSE, accounts for the deviation of the actual surface normal from the ideal profile. It is evaluated by the angular standard deviation and measured in mrad. Besides, since the reflective surface is composed by several facets, the concave profile is usually obtained by a collective arrangement of those facets, oriented in defined angles. This technique is known as canting strategy. Finally, the mirror support structure consists of the connection between the facets and the backing structure. Since it defines the manufacturing process and is in charge of fixing the mirror shape, it has a significant impact in the facet design because it influences both the cost and the performance of the heliostat [13] [15]. Mirror support structure 1. Point supported facet The point supported facet concept is to connect the facet by adjustable pins. The pins are glued to the mirror by pads to increase the surface of connection as shown in Figure 1.8. The number of pads is the result of the wind loads and the desired curved shape. By
10 1.1. BACKGROUND Figure 1.8: Point supported facet by pins and pads, Ivanpah, USA [16]. using this concept, the different thermal expansion of the glass and the backing structure material does not create complications. An extensive illustration of the fabrication and assembly process was published by Brightsource Energy [16]. 2. Stamped mirror facet Figure 1.6 provides an example of stamped mirror facets. The support structure is normally made of steel. In this way, the facet is reinforced by the steel structure due to the greater contact area, thus the glass thickness can be reduced [15]. The steel support geometry is optimized to provide the highest support at minimum weight. The fabrication process is taken from the automotive industry, thereby it is conceived for high volume production operated by automation, which could lead to lower the manufacturing cost and the fabrication time [11]. 3. Sandwich panel mirror facet The sandwich concept was designed to have a facet durable, easy to manufacture with reasonable material cost and good optical properties. Figure 1.9: Scheme of sandwich facet assembly [14]. The "sandwich" name comes from the manufacturing process: a float or annealed glass mirror is glued to a support made of carbon-steel layer, a core material (normally a poly-
CHAPTER 1. INTRODUCTION 11 meric foam) and a carbon-steel back membrane, which then is deformed by a mandrel into the desired curved shape, as shown in Figure 1.9 [13] [14]. Sandwich facets have raised such a considerable interests that Sandia completed several studies with US manufacturers investigating the possibility of reducing the facet cost of 25% while maintaining the surface slope error at 1 mrad [17]. On the other hand, sandwich facets tend to suffer from thermal deformation due to the different materials expansion and from creep [14]. 1.1.4 STERG’s HelioPod STERG developed the HelioPod heliostat technology through a Technology Innovation Agency funded innovation initiative [18]. The HelioPod is distinguished from other conventional heliostats by six heliostats sharing a common mounting structure. Such a system is referred to as a HelioPod. (a) Front view. (b) Rear view showing the sandwich facet. Figure 1.10: STERG’s HelioPod system with six facets of 2.23 m2[18]. Some benefits and reasons behind the HelioPod design, shown in Figure 1.10, are the following: •No need for costly ground preparation works; •Modularity; •Re-deployability. Furthermore, STERG focused its effort in developing a turnkey product which, besides not needing heliostat foundation works, is fully-autonomous as well. This is possible by omitting trenching for cabling, by replacing them with wireless communication and a PV/battery powered heliostats. On top of the listed benefits, the system is claimed to have excellent optical performance [23]. The cost of the demonstration technology was estimated at 144 USD/m2and it is expected that, for high production rates, a cost below 100 USD/m2can be achieved, down to 85 USD/m2in the optimistic scenario [19]. Table 1.2 lists some significant specifications of the HelioPod in its current design [20]. The HelioPod’s common pedestal can be manufactured at any customized size, which then determines
18 2.1. DEFINITION The daily optical efficiency gives an clear and immediate idea of the heliostat performance rather than the intercepted solar irradiation, ˙ Qf: the value is within 0 and 1 and it takes into account the performance of the entire day. In addition, the daily efficiency is a relevant parameter for TES system where the objective is the cumulative energy rather than the accumulated energy in a specific hour. Otherwise, the alternatives options were either to take into account only the performance at noon, which would have neglected the contribution of the heliostats that perform better in other hours of the day, or to display the optical efficiency of the several daily hours, which would have been impractical. Furthermore, instead of the heat flow rate, the optical efficiency, which is a relative performance indicator, disregards the dependency on the DNI and evaluates the field performance according to the sun angles. For the scope of the thesis, the performance analysis must distinguish the efficiency among the heliostats and the daily optical efficiency of the individual heliostat suitable for the purpose. The daily optical efficiency of the heliostat field is given in Eq.(2.4). It is a high level performance indicator of the heliostat field as it does not allow to distinguish the performance among the heliostats. It was used to provide the performance assessment of the overall field and for comparison’s purposes. ηf,day +PNhr Pf h˙ Qh PNhr DNI ·Nh·Ah =1 Nh f X h ηh,day (2.4) If the performance assessment concerned more than one day, it would be erroneous to calculate the performance parameters as the arithmetic average because it would sum up ratios having different denominators. The optical efficiency over a number of days, Ndays, of the individual heliostats, ηh,Ndays, and of the field, ηf,Ndays, are given in Eq. (2.5) and (2.6). ηh,Ndays +PNdays PNhr ˙ Qh PNdays PNhr DNI ·Ah6=1 Ndays Ndays Xηh,day (2.5) ηf,Ndays +PNdays PNhr ˙ Qf PNdays PNhr DNI ·Nh·Ah6=1 Ndays Ndays Xηf,day (2.6) 2.1.2 Design day and Representative days Finally, the last definition regards the nominal design conditions: design DNI value, date, time and location. The location of the CR plant is in Ouarzazate, Morocco and the TMY, with the solar angles, was used, received through personal communication with Azelio. The purpose of the design day is to create a reference for the CR plant, which must be clearly stated. The design day is normally the spring equinox, although a common consensus was not found in the literature. However, the DNI values of March 21st given in the TMY file were significantly lower than the monthly average, thus suggesting the case of a day with not clear sky. The thesis has the objective to design heliostat field with specific heat flow rate at the design point, which is at noon of the design day. As a consequence, since the heat flow rate, ˙ Qf, is
CHAPTER 2. RAY-TRACING MODEL 19 absolute performance indicator and depends on the DNI, the design day must have fair values of the expected DNI. For this reason, March 22nd was selected as design day. Table 2.1 lists the solar beam irradiance for the design day, the summer and winter solstice. These three are widely accepted as three representative days of the year for CSP field design. Table 2.1: Solar beam irradiance at representative days for CSP field design. DNI Local Time [W/m2] 6 7 8 9 10 11 12 13 14 15 16 17 18 22nd Mar - 344 876 966 1002 1018 1024 1019 1005 973 899 393 - 21st Jun 266 712 798 829 824 836 836 852 863 869 837 743 281 21st Dec - - 414 876 962 993 1001 990 953 855 662 - - In conclusion, in the thesis the optical efficiency is in charge of assessing and comparing the performance of the individual heliostats and of the field but the intercepted solar irradiation at the design point is the mean for accomplishing the objective. 2.2 Model Description The ray-tracing model is suitable for the scope of the thesis because it addresses the radiation flux prediction at the target surface. Among the several ray-tracing software packages widely used for concentrating system simulation and publicly available, Tonatiuh (version 2.2.4) is used for this project. Tonatiuh is an open-source software which, by its script editor, allows a full control of the simulations and fast adaptation to any changes [24]. The model is composed by three main components: the sun shape and position, the heliostat field and the tower structure. Figure 2.2: Tonatiuh model after a sample simulation with 103rays. Further details of the Tonatiuh model are provided in the Appendix A.
20 2.2. MODEL DESCRIPTION 2.2.1 Sun Shape and Position The sun shape is the radial distribution of energy considering the sun as a non-punctual source of light. Figure 2.3: Angle subtended by the sun. The rays of sunlight coming from the sun are not parallel. The rays emitted from the sun subtend an angle of approximately 9.3 mrad [5], as is shown in Figure 2.3. Tonatiuh provides two different sun shape’ models: Buie and Pillbox. Buie model offers a realistic sun shape [25], nevertheless its level of details was not relevant for the thesis’s purpose and the Pillbox model is much simpler. Pillbox sun shape defines the solar disk as a constant source of light with constant solar irradiance over the cone of directions. Table 2.1 lists the DNI while the sun angles were taken by the TMY file. 2.2.2 Heliostat Field Component The heliostat field is created by Tonatiuh’s "Heliostat Field Wizards" add-in. It needs three characteristics: the heliostats coordinates, their optical and structural properties and the aiming point. The heliostats coordinates are given by a .TXT file generated in MATLAB according to the heliostat field layout while the other characteristics are inserted in Tonatiuh. (a) Heliostats coordinates in MATLAB (b) Heliostat size and optical properties in Tonatiuh. Figure 2.4: Sample of generic HelioPod field layout.
CHAPTER 2. RAY-TRACING MODEL 21 Figure 2.4(a) shows an example of a field layout using HelioPods with densely-packed arrangement disposed horizontally created in MATLAB. The tower is located at the origin (0,0), pointed out with a filled red dot. The reason behind the field layout arrangement is due to the absence of optimization tool, clarified in Section 1.4. The HelioPod structure imposes a certain X and Z distance between one heliostat and the near one, which depends on the side length. The densely-packed assumption aims to replicate the heliostat distance in the common structure also between one HelioPod and the neighbour. Therefore, no disputable decision is taken since setting a certain horizontal and vertical distance between HelioPods and a certain titled angle respect to the horizontal line are only possible after a comprehensive optimization study [21]. Likewise, the distance between the tower and the first raw of heliostats in the oversized field was set to 3.3 m, which correspond to the Z distance between the center of gravity of the HelioPods in first and second row. Further information of the heliostats coordinates generation in MATLAB are provided in the Appendix B. The optical and structural properties are illustrated in Figure 2.4(b), which shows the Tonatiuh’s "Heliostat Field Wizard" window. The HelioPod facet size and shape were listed in Table 1.2. According to Section 1.3, at this stage of the thesis each facet is adapted to the tower. Therefore the radius of curvature of the facet spherical shape, R, was set equal to twice the slant range. Since the slant range, s, is the distance from the heliostat to the receiver, it means that each heliostat focal point, f, is exactly where the receiver is located. (R+2·f R= 2 ·s=⇒f=s(2.7) The mirror reflectivity was set to 95% according to typical low iron glass in CSP industry [5]. Finally, a sigma slope error, SSE, is required to take the real facet imperfection into account. According to literature [26], it was calculated as the root mean square of the HelioPod current surface slope + shape error and tracking error, σtrack, listed in Table 1.2, which is equal to 1.118 mrad. This combination of the two different errors is due to the impossibility to assign the tracking error to the aiming point in Tonatiuh. Each ray-tracing simulation sets an aiming point, which directs to the receiver aperture coordinates position (0,14,0). This model set-up reinforces the reason to consider the tracking error within the sigma slope. 2.2.3 Tower Structure Component Azelio provided a geometric model of a tower structure including the tower struss, cavity walls, absorber and cabinet, whose some specifications were given in Table 1.1. (a) with the cabinet. (b) without the cabinet. Figure 2.5: Azelio receiver model in Tonatiuh located at the top of the tower structure.
22 2.3. POST-PROCESSING AND OUTCOMES The cabinet is the component shown in Figure 2.5(a), which contains the cavity, the absorber, the TES and Stirling engine. Therefore, it is relatively big and it casts a shadow on the heliostat field. On the other hand, the tower struss minimizes the shadowing effect letting the majority of sun’s rays pass through. The main advantages of the ray-tracing model are its capability to 1) target a specific surface (referred to as export surface) considering the real system geometry; 2) quantify the amount of solar irradiation intercepted by the export surface; 3) predict the flux distribution. There are two export surfaces in the model: one located at the absorber position and the other at the receiver cavity aperture. The former export surface was used for the calculation of the performance indicators. Because of its position, the heliostats able to reflect the irradiation towards the absorber were naturally privileged in terms of greater performance. The latter was modelled in Tonatiuh as "virtual surface", which means that it did not collide with any sun’s rays but it was used to account for the ratio between the heat flow rate which effectively hits the former export surface and the heat flow rate entering into the cavity. The heliostat field’s aiming point is the center of the receiver cavity aperture, thus in the center of the latter export surface. Figure 2.5(b) shows the receiver system without the cabinet. The export surface is visible at the top of the cavity walls in the absorber position. The cavity walls are the secondary concetrators and ,after personal communication with Azelio, the cavity walls were material in Tonatiuh were set with 75% specular refectivity. 2.3 Post-Processing and Outcomes Tonatiuh is used to run ray-tracing simulations and its results are exported and treated in MATLAB for elaboration. The outcomes export was implemented in the Tonatiuh script: in each simulation a .txt file was generated containing the heat flux values recorded at the export surface. Hence, the maximum heat flux and the intercepted solar irradiation are read by opening the export .txt file in MATLAB. However, if the Tonatiuh model receives the coordinates of the all field with a mirror reflectivity of 95% as "Heliostat field table" input, the outcomes will give the solar irradiation intercepted by the overall heliostat field, in which ˙ Qfis not obtained as sum of each heliostat, ˙ Qh, but it is calculated as a single ray-tracing simulation of the entire field. Figure 2.2 shows a sample simulation in which the sun’s rays hit every heliostats in the field and the tower structure. As a consequence, only the overall performance will be available but it will not be possible to identify and distinguish how the individual heliostat in the field is performing. On the other hand, if the user decides to run simulations for each heliostat alone giving the coordinates only of one heliostat and not of the entire field, then the outcomes will not consider the shadowing and blocking effect on that heliostat, which is one of the reasons why the raytracing model is being used. An unprecedented (not listed in the literature) solution to get around this limitation consists of giving the property of 95% reflectivity only to the single heliostat under analysis whereas the all remaining field has 0% reflectivity. The individual heliostat is then the only one to reflect the sun’s rays and the export surface records only its performance, while all other heliostats are modelled in the field and able to interfere or block rays. The validation of this single heliostat simulation is given in Appendix A. Furthermore, the sun’s rays were set to hit only the single heliostat under simulation. Figure
CHAPTER 2. RAY-TRACING MODEL 23 2.2 shows the opposite case in which the sun’s rays had to hit the entire field, which provokes unintended rays’ dispersion among the heliostats and on the tower structure. Nevertheless, the processing time of the simulations was further increased. The assessment for any heliostat field layout was carried out by selecting each heliostat one by one and ran the raytracing simulation for the sun hours of the day. For instance, taking into account a field layout with 330 heliostats, as shown in Figure 2.4(a), evaluated in the design day with 11 sun hours, it means that the script would run 330 ×11 simulations and generate 330 ×11 .txt export files. 2.4 Accuracy of Outcomes There are two ray-tracing intrinsic characteristics which affect the accuracy of the outcomes: the shadowing impact of the tower in the hourly simulations and the number of rays. Ideally, the shadow of the tower cabinet should follow a daily arc and influence the performance of every heliostats over that arc only for the actual time that the shadow covers them. However, since the Tonatiuh model was set to run hourly simulations, the shadow was concentrated on a spot and affect the performance of that spot for the entire hour. This impacts the findings but 1) it is not relevant for the high level analysis of the thesis and 2) running simulation for time intervals smaller than one hour was not practical. The predicted shadow location will always be highlighted in the plot by black circle on the field, calculated by the daily solar angles, to point out the affected heliostats. Although the sun hours of day in the design day simulations are eleven, the number of circles in the charts is only seven, thus representing the shadow during the following local time: 9.00, 10.00, 11.00, 12.00, 13.00, 14.00, 15.00. This is because the shadow during the remaining hours is away from the interested field. The last essential input parameter for running simulation in Tonatiuh is the number of rays. In Monte Carlo ray-tracing, the solar irradiation is modelled as number of rays whose the stochastic paths of the rays are traced as they interact with the components of the model [27]. (a) Sample number 2 of 12. (b) Sample number 10 of 12. Figure 2.6: Efficiency values of a heliostat repeating simulations 10 times at different number of rays.
24 2.4. ACCURACY OF OUTCOMES The accuracy of the outcomes was tested by conducting several iterations to find the number of rays for which the model results stabilize. A small field of twelve heliostats was analyzed by running the daily simulation for 10 iterations setting different number of rays: 5×104,105, 5×105and 106. The objective was to quantify the variation of the heliostats optical efficiency value over the simulations. Figure 2.6 shows the test on two of the twelve heliostats; the horizontal axis is logarithmic. The accuracy of the outcomes is notable and unprecedented if compared to other case available in the literature [27] [28]. The substantial accuracy achievement was due to the individual heliostat simulation set-up which focuses the all number of rays on a single heliostat. Besides, the values distribution is reduced again when the daily efficiency of the 12 heliostats field is assessed. Figure 2.7: Efficiency values of a field composed by 12 heliostats repeating the simulation 10 times at different number of rays. Figure 2.7 shows that the daily optical efficiency of the field, considering only 12 heliostats, is almost constant, making the advantage of higher number of rays marginal in terms of gain in accuracy. Despite the accuracy study’s obvious consequence would be to run simulation with 106rays, the processing time for simulations has not been mentioned yet. In fact, if the field simulations with 105rays took roughly around 40 minutes with the available computing power, the time went up to 1 hour and 30 minutes each field simulation with 106rays. In conclusion, in the thesis the performance outcomes are generated with 105rays because their accuracy is considered acceptable for presenting and discussing reliable findings. However, for extremely precise results before moving for next steps, the outcomes should be generated having the highest accuracy possible with 106rays or more.
Chapter 3 Heliostat Field Layout Design A heliostat field layout design is a complex task with no clear objective function. If it aims to maximize the field optical performance, many additional factors need to be accounted for such as heliostat collision, land profile, maintenance access and water drainage [32]. The layout selection/design is inherently coupled to the thermal requirements of the receiver system. Utility scale plants, at scale of above 10 MWe, use surrounding heliostat fields with external receivers, shown in Figure 3.1(a), due to higher annual energy collection compared to polar fields [33], shown in Figure 3.1(b). However, the polar field is the most suitable configuration for small scale power generation with high flux requirements [34]. In addition, the geometry of Azelio small cavity receiver leads to deploy tighter heliostat fields, being careful not to incur additional blocking losses [6]. (a) Surrounding field (b) Polar field Figure 3.1: Heliostat field layouts with radial arrangement. A badly designed field layout negatively affects the heliostat technology performance. As a consequence, a dedicated high level study is presented in the chapter below. 26
CHAPTER 3. HELIOSTAT FIELD LAYOUT DESIGN 27 3.1 Assumptions The key assumptions are listed below. They may affect both field layout creation and assessment. •Densely-packed arrangement •Export surface located at the absorber position •Mirror reflectivity equal to 95% •Focal length of each heliostat equal to the slant range •Facet aperture size is fixed 3.2 Procedure Each nominal heat flow rate case requires a dedicated heliostat field layout, which is obtained through the following methodology. Although the best heliostat field layout is achieved by optimization, not using it does not necessarily mean deploying inefficient field layouts with poor outcomes. Figure 3.2: Flow chart of heliostat field layout design’s methodology. 1. As a first step, an oversized heliostat field will be modelled. Its size covers the field from the tower until a reasonable field length and width. The oversized field has the goal to define an efficiency map regarding any heliostat located in the field to enable selecting the most suitable ones. On the other hand, the alternative would have consisted of creating a specific field layout related to each targeted nominal heat flow rate, then moving the layout to find the best distance from the tower and playing around different dispositions to find the most performing. 2. The oversized field layout was designed over three representative days of the year. Design day, summer and winter solstice are widely used for designing purposes because the performance of the remaining days can be roughly estimated as the interpolation of their sun angles. The restriction of three days simulations instead of annual simulations was given by the ray-tracing model, which would require an excessive amount of time. Thereafter, any three days optical efficiency refers to the indicator calculated as in Section 2.1.1 using the results of simulations over design day, summer and winter solstice.
34 4.2. DECISION MAKING The purpose is to develop a figure of merit for quantifying the solar irradiation intercepted by the absorber with increasing number of HelioPods. The HelioPods were selected in order of yearly performance and the heat flow rate capacity is defined as the heat flow rate reflected by the field at the design point, ˙ Qf,design. Table 4.1 lists the heliostat fields which provide heat flow rate capacity around Azelio’s thermal needs. When a HelioPod pedestal is installed in the field, then all six mirrors are mounted on it. Therefore, this creates a discrete heat flow rate capacity behavior, which is characteristic of the heliostat technology [21]. The assumption is made for the logical reason of fully exploiting each installed common structure and because the HelioPod cost is currently estimated for a complete system with six facets. Table 4.1: Heat flow rate capacity of a set of heliostat fields. HelioPods [-] 7 10 13 14 17 18 ˙ Qf,design [kWth] 83.9 121.4 155.1 165.6 198.5 207.6 4.2 Decision Making The nominal heat flow rates are the desired values that Azelio is looking to attain with a corresponding number of heliostats. However, the discrete behavior of the HelioPods does not allow the absorber to intercept the exact nominal heat flow rates. In addition, some of the assumptions, such as the design day, affect the results of the heat flow rate capacity, therefore the size of a heliostat field should not only be based on it exceeding the nominal heat flow rate but also on the daily heat intercepted by the absorber. While 7 and 10 HelioPods layout were clearly suitable given the proximity to the targeted thermal needs, Figure 4.1 proves the previous statement since 160 kWth lays in the middle of the heat flow rate capacity of a heliostat field with 13 and 14 HelioPods. 13 HelioPods was discarded because, over the iteration improvement process, it never achieved the thermal requirements. Therefore, 14 HelioPods layout was chosen. (a) First iteration of selection. (b) Selection with the highest efficiency. Figure 4.2: Selection of best performing HelioPods for 200 kWth case.
CHAPTER 4. HELIOPOD PERFORMANCE ASSESSMENT 35 On the first iteration, 17 HelioPods layout obtained by the densily-packed arrangment of 4.6 m pedestal provides 202 kWth at the design point, as shown in Figure 4.2(a). Therefore, 17 HelioPods were considered suitable for 200 kWth case. Continuing the improvement iteration process shown in Figure 3.2, the heliostat field with 17 HelioPod increased by almost 1% at cost of slightly decreasing the heat flow rate capacity. Prioritizing the heat intercepted over three days, 17 HelioPods layout shown in Figure 4.2(b) was chosen. 4.3 Dedicated Heliostat Field Layouts The HelioPod performance assessment comes with the heliostat field layout. The layout for each analyzed nominal heat flow rate case is illustrated with the actual solar irradiation intercepted by the absorber at the design point, ˙ Qf,design, the number of HelioPods and the field efficiency over the three selected days, ηf,3days. As expected, the generated heliostat field layouts are symmetrical and polar. (a) 7 HelioPods field layout. (b) 10 HelioPods field layout. (c) 14 HelioPods field layout. (d) 17 HelioPods field layout. Figure 4.3: Dedicated layouts for Azelio thermal needs with three days performance. Their actual solar irradiation intercepted by the absorber at the design point is respectively
36 4.4. SENSITIVITY ANALYSIS ON CAVITY APERTURE DIAMETER 84.0 kWth,121.4 kWth,165.8 kWth and 198.5 kWth.1 The performance assessment, shown in Figure 4.3, highlights that the proposed heliostat field layouts are compactly disposed more over the field length (Z position) rather than the field width (X position) due to the performance behavior in summer and winter solstice. The homogeneous performance in each layout confirms low shadowing and blocking losses as well as relatively low spillage losses. Every dedicated field layout fits in the narrow area of high energy collection delineated by the efficiency map in Figure 3.6. Therefore, the HelioPod technology demonstrated to achieve the target nominal heat flow rate by deploying the best performing area of field, such as required by the cavity geometry. 4.4 Sensitivity Analysis on Cavity Aperture Diameter The spillage losses are minimized either by valid heliostats able to concentrate the image into the cavity or by enlarging the aperture area of the receiver. However, the surface of the receiver is typically limited for several practical reasons, such as the high flux requirements to reach the temperatures required by the power block, economic implications of a large receiver and the radiation and convection losses [11]. The purpose of the sensitivity analysis is to quantify the impact of smaller cavity aperture diameters on the field performance also in terms of evaluating the HelioPod’s theoretical goodness in imaging size. Figure 4.4: Field optical efficiency and heat flow rate capacity with smaller cavity diameters.2 1Small deviation with the selection results in Table 4.1 is due to the fact that the dedicated field layouts are newly simulated in Tonatiuh model in order to consider the actual shadowing and blocking effect on the layout edges, while the selection results uses the performance values from the oversized field layout.
CHAPTER 4. HELIOPOD PERFORMANCE ASSESSMENT 37 The Tonatiuh ray-tracing model was adapted to perform the simulation for different cavity diameters. In fact, both the cavity walls and the cavity aperture must be re-sized by a scale factor. Therefore, the all receiver system became smaller with the cavity aperture diameter. The layouts of the sensitivity analysis are provided in Appendix C. Figure 4.4 suggests that the dedicated heliostat fields for 80 kWth,120 kWth and 160 kWth maintain the nominal heat flow rate with smaller cavity aperture. Nevertheless, the three days optical efficiency decreases significantly within 2.5% and 4.5% depending on the case. The dedicated field for 200 kWth, which shows the highest three days efficiency loss, manifests a nominal 5 kWth difference between the largest and smallest analyzed cavity diameters. As a consequence, the heliostat field layout using 17 HelioPods may not comply the heat flow rate requirements and 18 HelioPods may be necessary. The layouts in Appendix C show that the HelioPods dispositions change for smaller cavity aperture, discarding location farther from the tower, while the number of HelioPods remains untouched. The mismatch within the trend of the heat flow rate at the design point and the three days optical efficiency of the field suggests that the majority of losses due to the smaller cavity aperture does not occur at noon but rather the difficulty in effectively hitting the absorber surface occurs in the first hours of the morning and in the late hours of the evening. The facet adaptation for smaller cavity aperture diameters was not developed. 2Small deviation of the field optical efficiency with cavity diameter of 0.65 m in comparison to Figure 4.3 due to origin of the results. In Figure 4.4, the performance indicators values were taken from the selection procedure, thereby the field layouts were not newly simulated in Tonatiuh.This affected the accuracy of the efficiency value but it was not relevant for trends of the high level sensitivity analysis.
Part II HelioPod Facet Adaptation 39
Chapter 5 Focal Lengths Identification Up to this point, the analysis has been based on the ideal case of adapting the focal length of each heliostat in the field. Those are referred to as theoretically achievable results. However, manufacturing a different facet focal length for each radial tower distance is impractical. In fact, to keep the heliostat field cost down, the suppliers opt for few mass manufactured facets [35]. The exact number of different facet focal lengths is the result of a dedicated techno-economic assessment for each CR plant [36]. Consequently, in this chapter the analysis moves a step forward to deal with the implication of having a small number of different facet focal lengths available. The purpose is to investigate if the current HelioPod facet is suitable for an Azelio tower and, if not, to identify the required facet adaptation to make the achievable results also feasible. 5.1 Assumptions •The analysis was conducted on the 17 HelioPods field layout to adapt the facets for the larger heliostat field and then evaluate how much the identified facets suit the smaller fields. The assessment of the smaller field layouts is presented in Appendix D. Figure 5.1: Ideal case’s daily efficiency of 17 HelioPods field layout in the design day. 40
CHAPTER 5. FOCAL LENGTHS IDENTIFICATION 41 •The identification was carried out by assessing the ray-tracing model in the design day. In fact, it will be demonstrated that the identification using three days gave the same results. Since the field layout was proposed with the three days performance, Figure 5.1 shows the performance assessment for the design day with the ideal case assumption in order to provide a graphical comparison with the results developed in this chapter. 5.2 Current HelioPod’s Facet Design STERG’s current HelioPods facet has a spherical rectangle with a curvature radius of 70 m, deployed in a demonstration plant of 200 kWth [11]. Hence, firstly there is the interest in evaluating the performance using current HelioPods with focal length of 35 m, whose cost and manufacturing information are available. (a) Individual heliostats daily efficiency. (b) Field hourly efficiency. Figure 5.2: Utilization of the current 35 m FFL in 17 HelioPods field layout. Figure 5.2(a) illustrates the performance of each individual heliostat with 35 m FFL whereas the comparison of hourly field optical efficiency, ηf,hour, between the ideal case vs 35 m FFL case is given in Figure 5.2(b). The performance assessment clarify that the current facet with relatively large focal length shows substantial drop in daily field efficiency compared to theoretical facets of up to 23%. The finding suggests that drop in performance is due to the high spillage losses given by the unsuitable facet focal length. On the other hand, a new heliostat field was designed to assess the current HelioPod facet for a dedicated layout which suits better the 35 m focal length. The heliostat field was composed by the 17 HelioPods, the same number of the previously proposed field layout. The HelioPods were disposed in a ring layout around a slant range of 35 m, shown in Figure 5.3(a). As a consequence, they were outside of the high annual energy collection area due to Azelio cavity geometry delineated by the efficiency map. Although Figure 5.3(b) shows that the new layout increased the field performance performance around the design point, the daily field performance is almost unchanged and the heat flow rate at the design point is only around 140 kWth. Therefore, the ray-tracing model suggests that neither with a dedicated layout the current HelioPod facet performance is acceptable due to
42 5.3. INCREMENTAL NUMBER OF FACET FOCAL LENGTH (a) Individual heliostats daily efficiency. (b) Field hourly efficiency. Figure 5.3: Utilization of the current 35 m FFL in dedicated field layout. the inability to effectively hit the absorber inside the cavity rather than due to spillage losses because the dedicated layout for 35 m facet had imposed to locate the HelioPods outside of the high annual energy collection area delineated by the efficiency map in Figure 3.6. These findings motivate the necessity of identifying new facet focal lengths to suit Azelio cavity receiver. 5.3 Incremental Number of Facet Focal Length The task is to minimize the spillage losses of the heliostat field with a incremental number of facet focal lengths. The identification variables analyzed were the number of facet focal lengths and the number of HelioPods assigned to each focal length. •The number of FFL defines the number of ideal radial location for the heliostats in order to minimize the spillage losses. Since the radial division of the heliostat field, the number of HelioPods assigned to each FFL cannot be an even distribution of the total amount; •The identification was determined by the focal length value which resulted in higher daily field optical efficiency; •For fields with two or more FFL, the performance assessment of an option deploying the current facet is presented because it is believed that its utilization would considerably decrease the number of unknowns; •The identification was completed when a set number of FFL levels out with the theoretical case performance.
CHAPTER 5. FOCAL LENGTHS IDENTIFICATION 43 5.3.1 One Focal Length In this case-study the entire heliostat field had the same facet and the identification of the FFL was obtained by running simulation in the ray-tracing model evaluating the field performance with different focal length values. (a) Field daily efficiency for design day. (b) Field three days efficiency. Figure 5.4: Identification of the best performing focal length for 17 HelioPods field layout with one FFL. Figure 5.4(a) resumes the daily field performance of the field with different focal length to point the maximum value out and to compare them with the ideal case displayed as higher boundary. The best performing facet with FFL equal to 23 m results in a performance penalty of 6% compared to the ideal case in the design day. Likewise, the identification was carried out with the three days performance, as shown in Figure 5.4(b), resulting in the same best performing facet and penalty compared to the corresponding ideal case. As a consequence, the next identifications will assess the ray-tracing model in the design day. The finding suggests that there is not any significant field performance improvement from 20 m to 25 m FFL due to a compensation effect in which almost the same amount of heliostat will benefit and lose performance when the FFL value moves in that range. In addition, the same performance penalty suggests that it is addressed to a factor which does not depend on the sun angles, such as the spillage losses. 5.3.2 Two Focal Lengths In this case-study, the heliostat field was divided in two rings according to the two focal lengths. Two ways to approach the task were pursued: 1. Assign the current FFL of 35 m to the 5 farther HelioPods and find the best performing FFL of the remaining 12 HelioPods field; 2. Find the best performing facet for both FFL, where the smaller FFL was assigned to the 10 HelioPods radially closer to the tower and the larger FFL to the remaining 7 HelioPods.
Chapter 6 Future Work With the intention to manufacture facets with shorter focal length, the future steps of the project following the submission of this thesis are given below: •A study is planned to FEM model the facet. This will give insight into the impact of cold forming the glass mirror onto the surface slope error. Sandwich facets with shorter focal length are then intended to be manufactured at STERG. The facets can then be assessed to validate the FEM model which will permit improved decision making on suitable facet designs for Azelio. •The development of a correlation within the surface slope error and focal length through a deflectometry system on prototype facets. The study has to take into account the HelioPod type of facet and its manufacturing process. In addition, logistic and manufacturing issues must be taken into account. The fabrication processes will depend on Azelio’s demand volume and location, whether the heliostats are made near to the field or shipped. 6.1 Facet Mechanical Deformation Prior to the current design of 35 m HelioPod facet, several samples of the annealed float glass mirror were tested to evaluate if the curvature was obtainable. Since the tempering option was discarded due to the high cost, the cold three-dimensional bending was selected. The experiment was conducted by applying vacuum and by forcing the float glass sample to take the parabolic shape of a 300 mm diameter circular glass. Figure 6.1 shows the breaking curvature and gave a reason to believe that the mechanical deformation of annealed float glass would have been feasible for the 35 m FFL [11]. The information of the sample aperture surface was not given. Given the lack of documentation about facets with short focal length, in-depth-study investigation are suggested where finite element method is the most widely used approach to deal with stresses in large glass panel [38]. 50
CHAPTER 6. FUTURE WORK 51 Figure 6.1: Radius of curvature at which float glass samples with different thickness broke during three-dimensional bending [11]. 6.2 Surface Quality Analysis Based on the experimental facts, the surface slope error tends to increase for facets with more and more curved profiles. However, the results obtained in the previous chapter are generated under the assumption of the same surface slope error for different facet focal lengths because there is not any validated nor widely accepted correlation between the facet’s radii of curvature and the surface slope errors. Causes of surface slope errors for sandwich facets are several including manufacturing imperfections, thermal, gravitational and wind load deformations [14]. This motives the need of the future work. In order to acknowledge the required accuracy of the facets prior to the future work, a preliminary study sets the boundaries of the minimum requirements that the slope error must withstand to ensure acceptable optical performance. A sensitivity analysis was carried out assessing the impact on field performance for the design day if the identified facets had a surface slope error of 0.8 mrad,1.6 mrad,2 mrad. The reference case was the surface slope error equal to 1.118 mrad, the higher errors investigated the experimental fact of higher slope errors for smaller focal lengths and the value of 0.8 mrad took into account the possible improvement of surface quality associated to the volume of production and specialization of the manufacturing process. The sensitivity analysis was carried out for the best performing combination of FFL in each number of focal lengths case. 6.2.1 One Focal Length The ray-tracing model of the 17 HelioPods layout composed by facets with 23 m in the design day ran simulations for each SSE. Figure 6.2 presents drop in daily performance with the increase of SSE. The studied SSE are expressed as a percentage variation of the reference case. The figure’s scope is to quantify the performance penalty due to the sensitivity parameter rather than the offset with the nominal
52 6.2. SURFACE QUALITY ANALYSIS Figure 6.2: Sensitivity analysis on SSE with one FFL. heat flow rate, which has been addressed previously. The one FFL case was previously classified as not suitable, however it is shown to provide comparison with the other FFL cases. The finding suggests a daily efficiency difference of 3% when deploying a facet with SSE of 2 mrad. Such a performance penalty is also due to the fact that the SSE variation was carried out on every heliostat of the field. The marginal daily efficiency difference with the improved case of 0.8 mrad suggests that the conservative assumption of SSE should have not affect the results significantly. 6.2.2 Two Focal Lengths The ray-tracing model with 18 m &28 m FFL was simulated with varying SSE. Both FFL are subjected to the sensitivity analysis, thus when the analysis on the SSE of one facet was carried out, the SSE of other facet was kept to the reference value of 1.118 mrad. Figure 6.3 shows that the sensitivity analysis on SSE of 28 m facet has a bigger impact on the field performance. Even though the 28 m FFL covers less than the half of the heliostats in the field layout, the finding suggests that the inaccuracy of the farther facets is more relevant than the inaccuracy of facets close to the tower: if the sensitivity on the 18 m FFL leads to almost 1% of daily performance drop, the sensitivity on the 18 m FFL is around 3%. 6.2.3 Three Focal Lengths Likewise, the analysis was carried out on the field composed by the combination of 15 m &20 m &28 m FFL. The first findings is that the surface inaccuracy of the 3 HelioPods with 15 m FFL almost does not the daily field performance. Since those heliostats have a suited facet, this behavior can be due to the cavity aperture area and to the proximity the tower because the heliostat imaging
CHAPTER 6. FUTURE WORK 53 Figure 6.3: Sensitivity analysis on SSE with two FFL. Figure 6.4: Sensitivity analysis on SSE with 3 FFLs. enlarges with the slant range. The daily performance penalty of 20 m FFL is 0.5% in comparison to the reference case, keeping in mind that the facet was assigned to 7 HelioPods. Finally, the sensitivity analysis on SSE of 28 m FFL shown in Figure 6.4 confirms the behavior previously presented in the two focal lengths case. Hence, it is further suggested that the facet which has to withstand the most strict accuracy requirements is the one deployed in the heliostats farther from the tower because its poor surface quality would badly influence the outcomes more than any other facet.
54 6.2. SURFACE QUALITY ANALYSIS 6.2.4 Summary of Findings The summary of the sensitivity analysis on SSE is now presented. To facilitate the comparison, the daily efficiency of each case-study was divided by the daily efficiency of its reference case to provide a percentage indicator of the performance penalty due to the SSE deviation. Figure 6.5: Summary of sensitivity analysis on SSE with different FFL. The SSE variation with the one FFL affected the every heliostat of the field. As a consequence, the finding motivates the importance of deploying an accurate facet in the case of 1FFL for the entire field. However, the 1FFL was suggested to not suitable due to the heat flow rate limitation. As expected, the sensitivity analysis on SSE of 28 m gave the same results for the 2FFL and the 3FFL case. Its finding suggests a minimum acceptable requirement of 1.6 mrad for not decreasing the nominal heat flow rate more than 195 kWth. Based on the experimental facts, the SSE tends to increase for facets with more and more curved profiles such as 15 m FFL. Nevertheless, the finding suggests that the surface slope quality contribution on the daily field performance is almost negligible.
Chapter 7 Conclusions There are many reasons to think that HelioPod technology is designed to operate with Azelio tower and it could provide a valid option for Azelio heliostat fields, such as the HelioPod size and optics, designed for small towers, and the innovative pedestal solution, for driving the heliostat field cost down according to the ambitious goal of 75 USD/m2set by SunShot initiative launched by US Department Of Energy [39]. A Tonatiuh ray-tracing model was setup to model a CSP plant with HelioPods and the Azelio tower to carry out the performance assessment. The analyzed variables to suit the HelioPod technology to Azelio tower were the design of the heliostat field layout and the adaptation of the facet focal length. Four dedicated heliostat field layouts using HelioPods were designed for achieving the nominal heat flow rate of 80 kWth,120 kWth,160 kWth and 200 kWth. The focal length of a set number of facets in the heliostat field was adapted to minimize the spillage losses. The developed methodology aims to provides insights for the development of a validated method in the field of heliostat facet optimization, which is listed as one of the twelve ways for driving the heliostat field cost down according to Sandia Power Tower Technology Roadmap and Cost Reduction Plan [37]. The ray-tracing model suggested that the dedicated heliostat fields can comply the nominal heat flow rate requirements by deploying respectively 7, 10, 14 and 17 HelioPods with a theoretical daily optical efficiency for the design day of 80.05%, 79.20%, 76.84% and 75.45%. A sensitivity analysis on the theoretical performance indicators demonstrated that the optical losses increased for smaller cavity aperture diameters, although the nominal heat flow rate remained almost constant. The high level study of facet focal length adaptation pointed out that a small number of facet focal lengths makes the performance penalty with the theoretical case become marginal. The best performing facets in the case of 2 FFL are 18 m &28 m, achieving a daily performance offset with the theoretical case around 1.5%, while in the case of 3 FFL are 15 m &20 m &28 m, leveling out the theoretical performance. Finally, a preliminary analysis of the facet surface slope error suggested that the SSE of short focal length facet such as 15 m, which is normally considerable due to the large curvature, does not affect the daily field efficiency significantly due to the proximity to the tower. The next step is to model the manufacturing process of new facets with different FFL. Thereafter, 56
CHAPTER 7. CONCLUSIONS 57 prototype facets can be produced. In-house deflectometry system at Stellenbosch University permits accurate assessment of the product and feedback to the finite element method model and the manufacturing process. The key finding is that STERG’s HelioPod is a possibly suitable heliostat for the Azelio tower if new and smaller focal lengths facets are developed.
Acknowledgements Special thanks to Azelio and Dr. Rafael Guedéz for assigning me such an exciting project. Both the faith for the CSP industry and the honor to deal with such a relevant topic for the company made me dedicate to the project with consistent hard-work and passion, aiming for being the bridge between two promising technologies. Personal acknowledgements go to Dr. Matti Lubkoll. Your contribution to my document was priceless as well as your guidance towards my findings. It was a pleasure to work with such a competent expert of the CSP field. I have learnt so much from you in each of our weekly meetings. I wish you the best for this new chapter of your life. Also, I would like to thank the all STERG team. I appreciated every single smile and chat with you in the office. You made the working environment so comfortable to me that it was a pleasure to go to the office every morning. I wish the best for your carriers and that we could keep in touch. Il riconoscimento più sentito va a tutta la mia famiglia. A Giulia, per avermi sempre sprontato a reagire e non lamentarmi, anche quando avevo la caviglia rotta. A mio papà, che è giovane dentro e che gli si illumano gli occhi quando parla di me. Grazie per essere un esempio di passione per il prioprio lavoro e non perdere mai l’entusiasmo. A mia mamma, a cui devo tutto. Che mi ha cresciuto, seminato principi dentro di me, insegnato a prendere decisioni e che ci è sempre stata. Non importa quanto viaggerò il mondo, per me casa sarà sempre accanto a te. A quei disperati dei miei amici. Tanto diversi uno dall’altro quanto unici quando tutti insieme. A voi che mi avete visto crescere e cambiare ma mi avete sempre voluto bene. To all the friends that I met abroad. Thanks for making me feeling home where home is so far away. To Vale, you are the only one that can take the best out of me. Every moment with you is and has been pure happiness. We built our own unforgettable world in South Africa and I want to live in that world again. Я тебя люблю, моя сладость. A final thanks goes to my younger self. Because leaving such a beautiful comfort zone was not easy at all. However, I felt that was right and indeed both the Erasmus and this Master program have definitely changed my life. 58
Appendix C Sensitivity Analysis on Cavity Aperture Diameter The development of this sensitivity analysis investigates the theoretical outcomes for scenarios with smaller cavity aperture area. The outcomes were generated according to the same methodology given in Figure 3.2, using the oversized heliostat field shown in Figure 3.4. Figure C.1: Heat flow rate capacity for incremental number of HelioPods with different cavity diameters. As a first step, the figure of merit regarding the heat flow rate capacity was updated with the outcomes of the smaller cavity diameters. The reference case of 0.65 m is differentiated by the smaller cases by the circle. While up to 8 HelioPods fields the heat flow rate capacity with different diameters is similar, Figure C.1 shows that, above it, the heat flow rate capacity of the HelioPod field increases with the cavity aperture diameter, as expected. The unexpected behavior occurs when the heliostat field layout among the cavity diameters cases is different. The results illustrate that the heliostat field layout changes disposition for smaller diameters and suggest that the HelioPods closer to the tower are better performing over 66
APPENDIX C. SENSITIVITY ANALYSIS ON CAVITY APERTURE DIAMETER 67 the three days. However, the heat flow rate capacity with a different layout is higher than the case with a larger cavity aperture. This finding further suggests the possible mismatch between the three days optical efficiency and the heat flow rate at the design point, mentioned also in Section 4.3. Although the heat flow rate capacity is the performance indicator for achieving the objective, the three days optical efficiency is the performance indicator used in the decision making for the design of the heliostat field layout. Since the latter takes into account the field performance over a larger amount of time, it is suitable for TES systems. Figure C.2: Dedicated layouts for each heat flow rate case with cavity diameter of 0.60 m. Figure C.2 shows the dedicated layouts with cavity diameter of 0.60 m, where the dispositions are identical to the case with cavity diameter of 0.65 m. Figure C.3 shows a change in layout disposition regarding the nominal heat flow rate case of 160 kWth with cavity diameters of 0.55 m. Again, the change in layout disposition brought a increase of heat flow rate capacity of 1 kWth in comparison to the case with cavity diameter of 0.60 m. On the other hand, the heat flow rate capacity of the largest field layout manifests an offset of 3 kWth with the nominal capacity.
68 Figure C.3: Dedicated layouts for each heat flow rate case with cavity diameter of 0.55 m.
APPENDIX C. SENSITIVITY ANALYSIS ON CAVITY APERTURE DIAMETER 69 Figure C.4: Dedicated layouts for each heat flow rate case with cavity diameter of 0.50 m.
70 Figure C.5: Dedicated layouts for each heat flow rate case with cavity diameter of 0.45 m.
Appendix D Suitability of Identified FFL for Smaller Field Layouts After having identified the suitable FFL for the proposed 17 HelioPods field layout, an analysis is conducted to evaluate the performance of the smaller dedicated field layouts with those FFL. The purpose is to find out if the identified FFL suits also the smaller fields. A performance assessment was carried out on the three dedicated layouts deploying the best performing combination of FFL for the case of one, two and three facets in the field. The hourly and daily field performance in comparison to the ideal case are presented for each dedicated layout. (a) Hourly performance for design day. (b) Daily performance with 1, 2, 3 or ideal FFL. Figure D.1: Performance assessment of 80 kWth with FFL combinations. 71
72 (a) Hourly performance for design day. (b) Daily performance with 1, 2, 3 or ideal FFL. Figure D.2: Performance assessment of 120 kWth with FFL combinations. (a) Hourly performance for design day. (b) Daily performance with 1, 2, 3 or ideal FFL. Figure D.3: Performance assessment of 1600 kWth with FFL combinations.
Bibliography [1] The World Bank – World Development Indicators (2017). Share of the population with access to electricity - Our World in Data. Available at: https://ourworldindata.org/grapher/share-of-the-population-with-access-to- electricity?year=2016 (Accessed June 2019) [2] Energy, I. A. (2008). ACCELERATING SDG 7 ACHIEVEMENT POLICY BRIEF 08 OF THE FIRST SDG 7 REVIEW AT THE UN HIGH-LEVEL POLITICAL FORUM 2018. [3] Steven Hunt; Andrew Scott; Liz Bates; Drew Corbyn. (2010). Poor People’s Energy Outlook 2010 - Practical Action Policy and Practice. https://doi.org/https://infohub.practicalaction.org/handle/11283/556942 [4] “Solar Resource Map”, World Bank, ESMAP, Solargis, 2016. Available at: https://globalsolaratlas.info/downloads/world (Accessed June 2019) [5] Stine, W.B. and Geyer, M.: Power from the Sun [Online] (2001). Available at: www.powerfromthesun.net (Accessed June 2019) [6] Li, L., Coventry, J., Bader, R., Pye, J., & Lipiński, W. (2016). Optics of solar central receiver systems: a review. Optics Express, 24(14), A985. https://doi.org/10.1364/OE.24.00A985 [7] Azelio, 2019. Available at: https://www.azelio.com/ (Accessed June 2019) [8] Nilsson, M., Abou-taouk, A., Sandberg, H., & Lindh, J. A Stirling Engine for Thermal Energy Storage, 1–8. [9] Mancini, T.R., Heller, P., Jones, S., Romero, M., 2000. Catalog of Solar Heliostats, SolarPACES Report No. III-1/00. [10] Torresol Energy, 2019. Available http://torresolenergy.com/en/ (Accessed June 2019) [11] Landman, W. A. (2017). Optical performance of the reflective surface profile of a heliostat, (March), 1–139. [12] Van Rooyen, D. W., Schöttl, P., Bern, G., Heimsath, A., & Nitz, P. (2016). Optical advantages of astigmatic aberration corrected heliostats. AIP Conference Proceedings, 1734(May 2016). https://doi.org/10.1063/1.4949050 [13] Coventry, J., Campbell, J., Xue, Y.P., Hall, C., Kim, J.S., Pye, J., Burgess, G., Lewis, D., 74
BIBLIOGRAPHY 75 Nathan, G., Arjomandi, M., Stein, W., Blanco, M, Barry, J., Doolan, M., Lipinski, W., Beath, A., 2016, Heliostat Cost Down Scoping Study – Final Report. ANU Document Reference: STG-3261 Rev 01, ASTRI, Australia. [14] Diver, R. B., & Grossman, J. W. (1998). Sandwich construction solar structural facets. Sandia National Laboratories, Albuquerque, NM. [15] Pfahl, A., Coventry, J., Röger, M., Wolfertstetter, F., Vásquez-Arango, J. F., Gross, F., ... Liedke, P. (2017). Progress in heliostat development. Solar Energy, 152, 3–37. https://doi.org/10.1016/j.solener.2017.03.029 [16] BrightSource Energy, Point supported facet fabbrication and assembly. Available at: https://www.youtube.com/watch?v=DWsqnomXFMg (Accessed June 2019) [17] Yellowhair, J., & Andraka, C. E. (2014). Evaluation of Advanced Heliostat Reflective Facets on Cost and Performance. Energy Procedia, 49, 265–274. https://doi.org/10.1016/J.EGYPRO.2014.03.029 [18] Landman, W. A. (2016). HelioPod Heliostat System for MGT CSP. STERG Symposium - July 2016.http://sterg.sun.ac.za/sterg-4th-annual-symposium-2016/ [19] Larmuth, J. N. (2015). Heliostat cost reduction methods applied to a small heliostat, (December). In: SolarPACES 2015 Conference. [20] Lubkoll, M., Hockaday, S. A. C., Harms, T. M., Backström, T. W. Von, Amsbeck, L., & Buck, R. (2018). Integrating solar process heat into manganese ore pre-heating. 5th Southern African Solar Energy Conference, SASEC2018, (June). Retrieved from http://sterg.sun.ac.za/wp-content/uploads/2018/08/SASEC2018_Lubkoll_M.pdf [21] Domínguez-Bravo, C. A., Bode, S. J., Heiming, G., Richter, P., Carrizosa, E., Fernández- Cara, E., ... Gauché, P. (2016). Field-design optimization with triangular heliostat pods. AIP Conference Proceedings, 1734(May). https://doi.org/10.1063/1.4949153 [22] Bode, S.-J., & Gauch, P. (2015). Heliostat Field & Pod Placement. STERG Symposium - July 2015.http://sterg.sun.ac.za/sterg-3rd-annual-symposium-2015/ [23] Helio100, 2019. Available at: http://helio100.sun.ac.za/ (Accessed June 2019) [24] Blanco, M. J., Amieva, J. M., & Mancillas, A. (2005, January). The Tonatiuh Software Development Project: An open source approach to the simulation of solar concentrating systems. In ASME 2005 International Mechanical Engineering Congress and Exposition (pp. 157-164). American Society of Mechanical Engineers. [25] D. Buie, A. G. Monger, and C. J. Dey. (2003) Sunshape distributions for terrestrial solar simulation. https://doi.org/10.1016/S0038-092X(03)00125-7 [26] García, L., Burisch, M., & Sanchez, M. (2015). Spillage Estimation in a Heliostats Field for Solar Field Optimization. Energy Procedia, 69, 1269–1276. https://doi.org/10.1016/j.egypro.2015.03.156 [27] Bode, S. J., Gauché, P., & Griffith, D. (2013). A novel approach to reduce ray trac-