scieee AI-readable full text Open interactive document viewer

Measurement of the 241Am neutron capture cross section at the n TOF facility at CERN

Mendoza, E.,Cano-Ott, D,Altstadt, Sebastian,Calviño Tavares, Francisco,Cortés Rossell, Guillem Pere,Gómez Hornillos, María Belén,Riego Pérez, Albert

Abstract

New neutron cross section measurements of minor actinides have been performed recently in order to reduce the uncertainties in the evaluated data, which is important for the design of advanced nuclear reactors and, in particular, for determining their performance in the transmutation of nuclear waste.We have measured the 241Am(n,gamma ) cross section at the n TOF facility between 0.2 eV and 10 keV with a BaF2 Total Absorption Calorimeter, and the analysis of the measurement has been recently concluded. Our results are in reasonable agreement below 20 eV with the ones published by C. Lampoudis et al. in 2013, who reported a 22% larger capture cross section up to 110 eV compared to experimental and evaluated data published before. Our results also indicate that the 241Am(n,gamma ) cross section is underestimated in the present evaluated libraries between 20 eV and 2 keV by 25%, on average, and up to 35% for certain evaluations and energy ranges.

Full text

EPJ Web of Conferences 146, 11022 (2017) DOI: 10.1051/epjconf/201714611022 ND2016 Measurement of the 241Am neutron capture cross section at the nTOF facility at CERN E. Mendoza1,a, D. Cano-Ott1, S. Altstadt2, S. Andriamonje3, J. Andrzejewski4, L. Audouin5,J.Balibrea 1,V.B ´ ecares1, M. Barbagallo6,F.Be ˇ cv´ aˇ r7, F. Belloni3, B. Berthier5, E. Berthoumieux3, J. Billowes8, V. Boccone, D. Bosnar9, M. Brugger10,F.Calvi ˜ no11, M. Calviani10, C. Carrapic¸o12, F. Cerutti10, E. Chiaveri10,3,M.Chin 10, N. Colonna6, G. Cort´ es11,M.A.Cort ´ es-Giraldo13, M. Diakaki14, I. Dillmann15, C. Domingo-Pardo2,I.Dur ´ an16, N. Dzysiuk17, C. Eleftheriadis18,M.Fern ´ andez-Ord´ o˜ nez1, A. Ferrari10,K.Fraval 3, V. Furman19,M.B.G ´ omez-Hornillos11, S. Ganesan20,A.R.Garc ´ ıa1, G. Giubrone21, I.F. Gonc¸alves12, E. Gonz´ alez1, A. Goverdovski22, F. Gramegna17, E. Griesmayer23, C. Guerrero10, F. Gunsing3, P. Gurusamy20,T.Heftrich 2, S. Heinitz24,A.Hern ´ andez-Prieto10,11, J. Heyse25, D.G. Jenkins26, E. Jericha23,F.K ¨ appeler27, Y. Kadi10, D. Karadimos14, T. Katabuchi28, V. Ketlerov22, V. Khryachkov22, P. Koehler29, M. Kokkoris14,J.Kroll 7,M.Krti ˇ cka7, C. Lampoudis3, C. Langer2, E. Leal-Cidoncha16, C. Lederer30,H.Leeb 23, L.S. Leong5, J. Lerendegui-Marco13,M.Licata 31,32,R.Losito 10, A. Manousos18, J. Marganiec4, T. Mart´ ınez1,C.Massimi 31,32,P.Mastinu 17, M. Mastromarco6, A. Mengoni33, P.M. Milazzo34, F. Mingrone31, M. Mirea35, W. Mondelaers25, C. Paradela16,A.Pavlik 30, J. Perkowski4, A.J.M. Plompen25, J. Praena13, J.M. Quesada13, T. Rauscher36,R.Reifarth 2, A. Riego-Perez11, M. Robles16, F. Roman35, C. Rubbia10,J.A.Ryan 8, M. Sabat´ e-Gilarte10,13, R. Sarmento12, A. Saxena20, P. Schillebeeckx25, S. Schmidt2, D. Schumann24, P. Sedyshev19, G. Tagliente6,J.L.Tain 21, A. Tarife˜ no-Saldivia21,D.Tarr ´ ıo16, L. Tassan-Got5, A. Tsinganis10, S. Valenta7, G. Vannini31,32, V. Variale6,P.Vaz 12, A. Ventura31, M.J. Vermeulen26, R. Versaci10, V. Vlachoudis10,R.Vlastou 14, A. Wallner37,T.Ware 8, M. Weigand2, C. Weiss23,T.Wright 8,P. ˇ Zugec9, and the n TOF Collaboration 1Centro de Investigaciones Energeticas Medioambientales y Tecnol´ ogicas (CIEMAT), Spain 2Goethe University Frankfurt, Germany 3CEA Saclay, Irfu, Gif-sur-Yvette, France 4University of Lodz, Poland 5Institut de Physique Nucl´ eaire, CNRS-IN2P3, Univ. Paris-Sud, Universit´ e Paris-Saclay, 91406 Orsay Cedex, France 6Istituto Nazionale di Fisica Nucleare, Sezione di Bari, Italy 7Charles University, Prague, Czech Republic 8University of Manchester, UK 9University of Zagreb, Croatia 10 European Organization for Nuclear Research (CERN), Switzerland 11 Universitat Polit` ecnica de Catalunya, Spain 12 Instituto Superior T´ ecnico, Lisbon, Portugal 13 Universidad de Sevilla, Spain 14 National Technical University of Athens, Greece 15 Technische Universit¨ at M¨ unchen, Garching, Germany 16 University of Santiago de Compostela, Spain 17 Istituto Nazionale di Fisica Nucleare, Sezione di Legnaro, Italy 18 Aristotle University of Thessaloniki, Thessaloniki, Greece 19 Joint Institute for Nuclear Research (JINR), Dubna, Russia 20 Bhabha Atomic Research Centre (BARC), India 21 Instituto de F´ ısica Corpuscular, Universidad de Valencia, Spain 22 Institute of Physics and Power Engineering (IPPE), Obninsk, Russia 23 Technische Universit¨ at Wien, Austria 24 Paul Scherrer Institut (PSI), Villingen, Switzerland 25 European Commission, Joint Research Centre, Geel, Retieseweg 111, 2440 Geel, Belgium 26 University of York, UK 27 Karlsruhe Institute of Technology, Campus North, IKP, 76021 Karlsruhe, Germany 28 Tokyo Institute of Technology, Japan 29 Oak Ridge National Laboratory (ORNL), Oak Ridge, TN 37831, USA 30 University of Vienna, Faculty of Physics, Vienna, Austria 31 Istituto Nazionale di Fisica Nucleare, Sezione di Bologna, Italy ae-mail: [email protected] c The Authors, published by EDP Sciences. This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0/). EPJ Web of Conferences 146, 11022 (2017) DOI: 10.1051/epjconf/201714611022 ND2016 32 Dipartimento di Fisica e Astronomia, Universit` a di Bologna, Italy 33 Agenzia Nazionale per le Nuove Tecnologie (ENEA), Bologna, Italy 34 Istituto Nazionale di Fisica Nucleare, Sezione di Trieste, Italy 35 Horia Hulubei National Institute of Physics and Nuclear Engineering, Romania 36 Department of Physics, University of Basel, Switzerland 37 Australian National University, Canberra, Australia Abstract.New neutron cross section measurements of minor actinides have been performed recently in order to reduce the uncertainties in the evaluated data, which is important for the design of advanced nuclear reactors and, in particular, for determining their performance in the transmutation of nuclear waste. We have measured the 241Am(n,γ) cross section at the n TOF facility between 0.2 eV and 10 keV with a BaF2Total Absorption Calorimeter, and the analysis of the measurement has been recently concluded. Our results are in reasonable agreement below 20 eV with the ones published by C. Lampoudis et al. in 2013, who reported a 22% larger capture cross section up to 110 eV compared to experimental and evaluated data published before. Our results also indicate that the 241Am(n,γ) cross section is underestimated in the present evaluated libraries between 20 eV and 2 keV by 25%, on average, and up to 35% for certain evaluations and energy ranges. 1. Introduction Isotopes of 241Am and 237Np are the minor actinides which contribute most to the long term hazard of the nuclear waste. The first one, with T1/2= 433 y, decays into 237Np (T1/2=2.1×106y) via αemission. Neutron capture reactions in 241Am, the most abundant Am isotope present in the spent nuclear fuel, are the path to heavier minor actinides like 243Am and Cm isotopes. In addition, the reprocessing of Am is technologically more advanced than for other minor actinides. For all these reasons the improvement of the 241Am(n,γ) data was a major effort of the EC-FP7 ANDES project, and four different measurements were planned and carried out. Two of them were capture measurements performed at nTOF [1], with the same sample but different detectors: the Total Absorption Calorimeter (TAC) [2] and C6D6 detectors [3]. The other two were a transmission and a capture measurement performed at IRMM – Geel [5], with a different sample. In this work we present the results of the measurement performed at n TOF with the TAC. 2. Experimental setup The measurement was performed in 2010 at the n TOF facility at CERN, which is a high instantaneous intensity spallation neutron source driven by the CERN PS synchrotron. We used the Total Absorption Calorimeter (TAC) [2] to detect the capture reactions as a function of the time-of-flight. This detector is made with 40 BaF2 crystals of 15 cm length covering ∼95% of the solid angle, and is used to detect in coincidence (nearly) all the γ-rays coming from the (n,γ) reactions. The neutron beam was monitored during the entire measurement with a 6Li foil based detector [6]. The detector signals were recorded by a digital data acquisition system [7] operating at 250 and 500 MSamples/s with 8 bits resolution, recording continuously a time of flight of 32 or 16 ms for each pulse (above 0.17 or 0.7 eV, since the time of flight is about 185 m). The sample [8] was made of 36.5 mg of 241AmO2 embedded in a 305 mg Al2O3matrix (to reduce/avoid inhomogeneities), and encapsulated in a 0.5 mm thick Al canning. The radius of the sample was 6.13 mm and the 241Am mass 32.23(10) mg (6.82 ·10−5atoms/barn). It was placed in the center of the TAC, shielded with 2 mm lead due to its high activity (∼4 GBq), and a spherical borated polyethylene neutron absorber (5/10 cm inner/outer radius), used to reduce the background due to scattered neutrons. In the analysis of the measurement we observed resonances of 237Np and 240Pu. We estimated the amount of these impurities as ∼0.029 (237Np) and ∼0.00049 (240Pu) times the number of 241Am atoms. About 2 months of beam time were dedicated to the 241Am measurement. 60% of the total amount of beam was dedicated to measure the 241Am sample, 36% to measure the different background components, and 4% to measure different 197Au samples in order to normalize the 241Am(n,γ) cross section by means of the saturated resonance method [9], using the 197Au strongest resonance at 4.9 eV. The number of events detected per proton pulse during the 241Am measurement and some of the background measurements (a dummy sample and the Al canning, and measurements without neutron beam with and without the sample in place) are presented in Fig. 1. Only the events with certain conditions in the detection multiplicity mcr (number of detectors in coincidence) and total deposited energy Esum (sum of the energies deposited in the detectors in coincidence) have been considered. Sm impurities present in the Al2O3matrix of the dummy sample but not in the 241Am sample are clearly visible. 3. Data analysis The basis of the analysis procedure was the same as other TAC measurements [10,11], with some additional features developed to deal with pulse pile-up effects not present in previous analysis. The detection efficiency has been determined from simulations, based in the DECAYGEN [12] code for the generation of the (n,γ) cascades and in a very detailed geometric modeling of the TAC [13] implemented in GEANT4 [14] for the transport of the γ-rays. The Photon Strength Functions of the compound nuclei (242Am and 198Au) used by DECAYGEN were modified until reproducing the experimental results (deposited energy histograms for different detection multiplicities), as it has been done in previous works [10,11]. An example of how well the experimentally obtained deposited energy distributions due to 241Am(n,γ) cascades are reproduced by the simulations is presented in Fig. 2. Three different 197Au samples were measured to normalize to the saturated resonance at 4.9 eV. The counting rates in the saturated part of the resonance 2 EPJ Web of Conferences 146, 11022 (2017) DOI: 10.1051/epjconf/201714611022 ND2016 (eV) n E 1 10 2 10 3 10 4 10 counts/pulse -2 10 -1 10 1 Am 241 Dummy sample Al canning Am - beam off 241 No sample - beam off )γSm(n, Figure 1. Number of events detected in the 241Am(n,γ) measurement as a function of the neutron energy, together with different background measurements and under the conditions of mcr >2and2.5<Esum <6 MeV. (MeV) Sum E 01234567 counts/ms 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 =0 cr m =1 cr m =2 cr m =3 cr m >4 cr m Simulated Figure 2. Experimental (solid lines) and simulated (dotted lines) deposited energy spectra from 241Am capture cascades for different mcr conditions. were quite high for the TAC (a few events per µs), and we used the third method described in [15] to correct for the pile-up effects. Each of the measurements were performed at two different pulse intensities, being the highest about 2.3 times more intense than the lowest. All the normalization values obtained with the different samples and the different pulse intensities were compatible within statistical uncertainties, which were close to 1% in all the cases. The overall normalization uncertainty is the sum of the uncertainties of the sample mass (0.6%), the detection efficiency (2%) and normalization to the 197Au resonance (2%), which amounts to 3% or 5%, depending on whether the quantities are added quadratically or linearly. The background components not related with the interaction of the neutron beam with the 241Am nuclei and the 237Np and 240Pu impurities were obtained from dedicated measurements. The background due to fission reactions in 241Am is very low, and was estimated from the JEFF-3.2 [16] fission cross section and by assuming a similar detection efficiency than for the capture reactions. The background due to elastic scattered neutrons in 241Am was estimated by measuring the effect of neutrons scattered in a graphite sample together with the JEFF-3.2 241Am elastic cross section. The effect of this component is negligible in the Resolved Resonance Region (RRR), since the neutron absorber is more effective at lower neutron energies, and very low (∼1%) in the Unresolved Resonance Region (URR). The effect of the 237Np and the 240Pu impurities were also taken into account from the cross section data available in the evaluations. The self-shielding and multiple scattering effects due to the 241Am sample and to the Al canning and the Al2O3matrix have been carefully studied by comparing calculations performed with SAMMY [17], MCNP- 6.1 [18] and GEANT4. In these calculations we obtained the theoretical capture yield under different conditions (with/without the Al canning, the Al2O3matrix, ...), finding that the results obtained with the three codes were in a reasonable agreement. The effect due to the 241Am is small (<2%) except for the first three resonances, where is around 10%. The effect of the Al canning is negligible, and the effect of the Al2O3matrix is to increase the number of detected capture events by around a 2%, nearly constant in the energy range of interest. Above 1–2 keV there are pile-up effects in the capture signals induced by the high background counting rate. This effect has been corrected with a method which is quite similar to the ones described in [15] and that will be published in a future work. Below 1–2 keV this effect is very small. The obtained capture yield has been analyzed with SAMMY, using a resonant description of the cross section up to 700 eV. The URR was analyzed up to 10 keV with the modified version of the FITACS code available in SAMMY. 4. Results Together with this measurement, other three 241Am(n,γ) measurements have been performed recently: one at nTOF using the same sample but C6D6detectors instead of the TAC [3] (Fraval et al.); other (together with transmission) at IRMM – Geel [5] (Lampoudis et al.) using a three times thicker sample, manufactured in the same laboratory and at the same time as the one used in this work; and the last one performed at DANCE [4] (Jandel et al.), in Los Alamos Neutron Science Center. Lampoudis et al. provided a capture cross section up to 110 eV which was, on average, around 20% larger than the results provided by Fraval et al. and Jandel et al., which are in reasonable agreement between them. The JEFF-3.2 neutron data library has adopted the results provided by Lampoudis et al. in the RRR (up to 150 eV) whereas the JENDL-4.0 [19] and ENDF/B-VII.1 [20], which are the same in the RRR, have adopted the results provided by Jandel et al. In the URR the three evaluated data libraries are quite similar. A comparison between the 241Am(n,γ) cross section we obtained and the evaluated ones is presented in Fig. 3. Our results are a bit below JEFF-3.2 for the first three resonances, and in in reasonable agreement up to 20 eV. Between 20 eV and 150 eV, our cross section is higher than the one in JEFF-3.2 by up to 10–15%, and also higher than the one in JENDL-4.0 and ENDF/B-VII.1 by up to 30–35%. In the low energy part of the URR, our results are higher than the evaluated ones by up to 20%, but above 1–2 keV our 241Am(n,γ) cross section is compatible with the evaluated ones. 3 EPJ Web of Conferences 146, 11022 (2017) DOI: 10.1051/epjconf/201714611022 ND2016 (eV) n E 0.2 0.4 0.6 0.8 1 1.2 1.4 (barn) γ σ 0 1 2 3 4 5 6 7 8 3 10× n_TOF JEFF-3.2 JENDL-4.0,ENDF/B-VII.1 (eV) n E 1 10 2 10 ratio 1 1.1 1.2 1.3 1.4 n_TOF/JEFF-3.2 n_TOF/JENDL-4.0,ENDF/B-VII.1 (eV) n E 3 10 4 10 (barn) γ σ 0 5 10 15 20 25 30 35 n_TOF JEFF-3.2 ENDF/B-VII.1 JENDL-4.0 Figure 3. Comparison between the obtained cross section and the evaluated ones. In the top pannel, the different cross sections for the first three 241Am resonances. In the middle, the ratio between them in the RRR. In the bottom panel, the different cross sections in the URR up to 10 keV. 5. Conclusions We have measured the 241Am(n,γ) cross section at n TOF with the TAC between 0.2 eV and 10 keV. Our results are compatible with the ones provided by Lampoudis et al. below 20 eV and with the evaluated cross sections above 1–2 keV. This results indicate that the present evaluations underestimate the 241Am(n,γ) cross section below 1 keV by up to 30%. This work was supported in part by the Spanish national company for radioactive waste management ENRESA, through the CIEMAT-ENRESA agreements on “Transmutaci´ on de residuos radiactivos de alta actividad” the Spanish Plan Nacional de I+D+i de F´ ısica de Part´ ıculas (project FPA2014-53290-C2-1) and the European Commission with the FP7 projects ANDES (FP7- 249671) and CHANDA (FP7-605203). References [1] C. Guerrero et al., Eur. Phys. J. A 49, 27 (2013) [2] C. Guerrero et al., Nucl. Instr. Meth. A 608, 424 (2009) [3] K.Fravaletal.,Phys.Rew.C89, 044609 (2014) [4] M. Jandel et al., Phys. Rew. C 78, 034609 (2008) [5] C. Lampoudis et al., Eur. Phys. J. Plus 128, 86 (2013) [6] S. Marrone et al., Nucl. Instr. Meth. A 517, 389 (2004) [7] U. Abbondanno et al., Nucl. Instr. Meth. A 538, 692 (2005) [8] C. N¨ astren, JRC-ITU-TN-2006/34 (2011) [9] R.L. Macklin et al., Nucl. Instr. Meth. A 164, 213 (1979) [10] C. Guerrero et al., Phys. Rew. C 85, 044616 (2012) [11] E. Mendoza et al., Phys. Rew. C 90, 034608 (2014) [12] J.L. Tain and D. Cano-Ott, Nucl. Instr. Meth. A 571, 719 (2007) [13] C. Guerrero et al., Nucl. Instr. Meth. A 671, 108 (2012) [14] C. Guerrero et al., Nucl. Instr. Meth. A 506, 250 (2003) [15] E. Mendoza et al., Nucl. Instr. Meth. A 768,55 (2014) [16] The JEFF team, http://www.oecd-nea.org/ dbdata/jeff, (2014) [17] N.M. Larsson, ORNL/TM-9179/R8 (2008) [18] J.T. Goorley et al., LA-UR-13-22934 (2013) [19] K. Shibata et al., J. Nucl. Sci. Technol. 48, 1 (2011) [20] M.B. Chadwick et al., Nuclear Data Sheets 112, 2887 (2011) 4