scieee AI-readable full text Open interactive document viewer

Retaining or excising the supraspinatus tendon in complex proximal humeral fractures treated with reverse prosthesis: a biomechanical analysis in two different designs

Carbonell Riera, Joan Miquel,Santana, Fernando,Palau Sanz, Edgar,Vinagre Ruiz, Manuel,Casals Gelpí, Alicia

Abstract

Purpose: We aimed to biomechanically evaluate the effect of the supraspinatus tendon on tuberosity stability using two different reverse shoulder arthroplasty (RSA) models for complex proximal humeral fractures (PHFs) Methods: Four-part proximal humeral fractures were simulated in 20 cadaveric shoulders. Two different RSA designs were implemented: a glenosphere-medialized model and a glenosphere-lateralized model. Tuberosities were reconstructed, and displacement of bony fragments was measured (mm) by placing three sensors: in the humeral diaphysis (D), in the greater tuberosity (GT), and in the lesser tuberosity (LT). Axial forces were induced and measured in Newton (N). The test was performed twice in each specimen, with and without the supraspinatus tendon. The regression line (RL) was measured in mm/N. Results: In the medialized model, the GT–D displacement was greater in the supraspinatus preserving model than that in the tendon excision model (p<0.001), as well as for the LT–D displacement (p<0.001). In the lateralized model, GT–D displacement and GT–LT distance were greater in the preserving model than that in the excision model (p<0.001, p=0.04). Conclusion: The supraspinatus tendon resection leads to a more biomechanically stable tuberosity construct when performing RSA for PHFs, while the rest of the rotator cuff tendons (infraspinatus and teres minor) are retained in the greater tuberosity.

Full text

1 Title Retaining Or Excising The Supraspinatus tendon in Complex Proximal Humeral Fractures Treated With Reverse Prosthesis? A Biomechanical Analysis In Two Different Designs Authors Miquel J (PhD)1, Santana F (PhD)2, Palau E (MD)3, Vinagre M (MD)4, Langohr K (PhD)5, Casals A (PhD)4,6, Torrens C (PhD)2 1. Orthopaedics & Trauma Department. Consorci Sanitari de l’Anoia. Barcelona 2. Orthopaedics & Trauma Department. Parc de Salut Mar. Barcelona. Universitat Autònoma de Barcelona. 3. Orthopaedics & Trauma Department. Hospital de Viladecans. Barcelona. 4. Center of Research of Biomedical Engineering Universitat Politècnica de Catalunya 5. Integrative Pharmacology and Systems Neuroscience Research Group. Neurosciences Research Program. Hospital del Mar Medical Research Institute (IMIM). Department of Statistics and Operations Research. Universitat Politècnica de Barcelona/Barcelonatech 6. Institute for Bioenginering of Catalonia (IBEC), The Barcelona Institute of Science and Technology Corresponding author Joan Miquel [email protected] Avinguda de Catalunya, 11 (08700) Igualada (Barcelona, Spain) DISCLAIMER: None The final publication is available at Springer via http://dx.doi.org/10.1007/s00402-018-3016-8 2 ABSTRACT1 Purpose2 We aimed to biomechanically evaluate the effect of the supraspinatus tendon on tuberosity stability using 3 two different reverse shoulder arthroplasty (RSA) models for complex proximal humeral fractures (PHFs)4 5 Methods 6 Four-part proximal humeral fractures were simulated in 20 cadaveric shoulders. Two different RSA 7 designs were implemented: a glenosphere medialized model and a glenosphere lateralized model. 8 Tuberosities were reconstructed, and displacement of bony fragments was measured (mm) by placing three9 sensors: in the humeral diaphysis (D), in the greater tuberosity (GT) and in the lesser tuberosity (LT). Axial 10 forces were induced and measured in Newton (N). The test was performed twice in each specimen, with 11 and without the supraspinatus tendon. The regression line (RL) was measured in mm/N.12 Results 13 In the medialized model, the GT-D displacement was greater in the supraspinatus preserving model than 14 that in the tendon excision model (p<0.001), as well as for the LT-D distance (p<0.001).15 In the lateralized model, GT-D displacement and GT-LT distance was greater in the preserving model than 16 that in the excision model (p<0.001, p=0.04). 17 Conclusion 18 The supraspinatus tendon excision had a positive biomechanical effect on tuberosity stability when 19 performing RSA for PHFs.20 21 Keywords: tuberosity reconstruction, reverse shoulder arthroplasty, supraspinatus, cadaveric study, rotator 22 cuff excision, complex proximal humeral fractures. 23 Level of evidence: Basic Science Study. Cadaveric Study 24 Click here to view linked References 3 INTRODUCTION 25 Reverse shoulder arthroplasty (RSA) has emerged as a viable treatment for complex proximal humeral 26 fractures (PHFs) in the elderly, and many studies have supported its use [1-3]. However, no consensus 27 exists regarding the need for tuberosity reattachment when treating complex PHFs with RSA. 28 The Grammont concept of reverse arthroplasty shifts the glenohumeral center of rotation (COR) inferiorly 29 and medially from the native joint, improving the efficiency of the deltoid [4, 5]. Lateralization of the COR 30 in RSA has been recently suggested as a potential benefit to limit the degree of scapular notching and 31 improve the range of motion. This can be achieved by designing extended or thicker glenosphere 32 components [6, 7] or using autograft bone spacers [8].33 In the early reports on the use of RSA for acute fractures, tuberosities were not routinely reattached and 34 were even resected [9]. Technical efforts have recently been performed to anatomically reattach the35 tuberosities[10], and this represents the current trend as described by several publications [2, 3, 11-13].36 Tuberosity healing after RSA for PHFs has been shown to contribute to external rotation strength 37 restoration [12, 13]. However, some controversy exists in the literature concerning the influence of 38 tuberosity healing on outcomes [14].39 The effect of the supraspinatus tendon on the greater tuberosity may represent a stress force that potentially 40 affects tuberosity healing. Because RSA was designed to work without a rotator cuff, the surgeon has the 41 option to preserve [3, 11] or excise [2, 12, 14] the supraspinatus tendon in complex PHF scenarios.42 The objective of this study was to biomechanically test the effect of the supraspinatus tendon on tuberosity 43 displacement using a medialized glenosphere design and a lateralized glenosphere design for the treatment 44 of PHF with RSA. We hypothesized that the supraspinatus tendon may play a negative role in the stability 45 of tuberosities when fixed to the humeral stem.46 47 4 MATERIALS AND METHODS 48 Twenty fresh-frozen cadaveric shoulders were used for this study, with a mean age of 62 (54-72) years.49 Specimens had not had previous shoulder surgery.50 Preparation of the specimens was performed according to a previous study description [15]. Two-thirds of 51 the distal clavicle, the entire scapula and the entire arm were initially included. Soft tissue superficial to the 52 rotator cuff was removed. All shoulders were dissected, and gross examination showed no evidence of 53 rotator cuff tears, arthritis, fracture or prior surgery. The medial third of the scapula was rigidly fixed to a 54 customized apparatus. 55 Fracture preparation 56 Two orthopedic surgeons reproduced a four-part proximal humeral fracture through the bicipital groove 57 using an oscillating saw to separate the greater tuberosity (GT) from the lesser tuberosity (LT) by splitting 58 the humeral head, as previously reported [16]. The rotator interval was also split to allow access to the 59 articular surface. A surgical neck horizontal osteotomy of the proximal humerus was performed that 60 preserved the subscapularis tendon fibers to reproduce the division of the humeral diaphysis (D) from the 61 tuberosities. The split humeral head was excised, and the tuberosities were then trimmed to obtain the 62 anatomic relationship when reduced around the humeral stem. 63 Reverse arthroplasty and the tuberosity construct 64 Two different RSA designs were employed. A Grammont medialized COR design RSA was implemented 65 in 9 specimens (Delta XtendTM, DePuy, Warsaw, IN) with the following implants: a standard 27-mm66 baseplate, a 42-mm centered glenosphere, a 10-mm monoblock humeral stem in a neutral position, with 67 155º of humeral inclination and a standard polyethylene insert sized according to the tension. 68 The remaining 11 specimens were used for the lateralized COR model with a 3.5-mm thicker glenosphere 69 (Humelock Reversed®, FX Solutions, Viriat, France). The specific implants included a 24-mm baseplate,70 a 36-mm centered glenosphere, a 10-mm humeral stem with 145º of humeral inclination and a polyethylene 71 insert sized according to the tension. 72 The humerus was then transected distal to the deltoid tuberosity to fix the specimen to an aluminum bench 73 vice. The tuberosities were reduced around the proximal humeral stem and sutured to the humeral shaft 74 according to Boileau’s suture technique [10] using #5 Ethibond Excel® (Ethicon, Somerville, NJ). 75 5 Sensor implantation and measurement technique 76 Three sensors were implanted in the final construct: one in the humeral D, one in the GT and one in the LT. 77 The sensor placement was guided by digital calipers to reproduce the same setup distances for each 78 specimen. Calibration was then performed to obtain a reproducible model to compare multiple analyses. 79 Consequently, three measurements were obtained for each experiment: the greater tuberosity to diaphysis 80 (GT-D) distance, the lesser tuberosity to diaphysis (LT-D) distance and the greater tuberosity to lesser 81 tuberosity (GT-LT) distance. 82 Progressive axial forces were induced through the supraspinatus, infraspinatus and subscapularis tendons 83 using #5 Ethibond Excel® (Ethicon, Somerville, NJ) sutures and measured in Newtons (N). A customized 84 traction device with a digital dynamometer (Dillon ED Junior Red Dynamometer®, Data Weighing 85 Systems, Elk Grove, IL) was used to apply force. 86 Displacement of the sensors was analyzed using a digital tracker that included position sensors and a digital 87 signal processor (Polhemus Liberty®, Polhemus, Colchester, VT). The test was performed twice on each 88 specimen: first with retention of the supraspinatus tendon and, second, after supraspinatus tendon resection. 89 Statistical analysis 90 Linear mixed models were applied to determine the effect of the supraspinatus tendon on the relationship 91 between the increase in distance and force. These models, fitted separately for each combination of implant 92 type and sensor, included the interaction of the supraspinatus tendon type and force as a fixed effect and 93 the individual as a random effect. 94 The slope of the regression line was measured in mm/N for each configuration to determine the effect size. 95 Both regression lines (with and without the supraspinatus tendon) were forced to pass through the origin 96 because the distance cannot be increased if no force is applied. The difference between the two regression 97 slopes was considered the effect size measure. A positive value indicated a larger distance increase with 98 the supraspinatus tendon given the same force as without the supraspinatus tendon. The level of significance 99 was set at p<0.05. All statistical analyses were performed with R (R Foundation for Statistical Computing, 100 Vienna, Austria.), version 3.3.1.101 6 RESULTS 102 For both the medialized and lateralized COR models, all interfragmentary distances increased according to 103 the forces applied, resulting in a positive regression line in all experiments (Fig. 1 and Fig. 2).104 The medialized COR RSA model showed significant differences in the GT-D interfragmentary 105 displacement when the supraspinatus tendon was preserved compared to that when it was resected (Fig. 1). 106 The model showed a higher regression line (RL) when the supraspinatus tendon was preserved than that in107 the model where the supraspinatus tendon was resected (p<0.001) (Table 1). The LT-D interfragmentary 108 distance (Fig. 1) exhibited a smaller regression line for the supraspinatus tendon excision model (RL: 0.047) 109 than that for the tendon preserving model (RL: 0.065, p<0.001). Regarding the displacement between 110 tuberosities (GT-LT distance), the construct showed small non-significant differences for the excision and 111 preserving models (p=0.07) (Table 1).112 In the lateralized COR RSA model, the GT-D interfragmentary displacement (Fig. 2) was greater in the 113 supraspinatus preserving model than that in the supraspinatus excision model for the forces applied 114 (p<0.001) (Table 1). The LT-D interfragmentary distance measurements (Fig. 2) showed no significant 115 differences with and without the supraspinatus tendon (p=0.97) (Table 1). Regarding the GT-LT distance, 116 a significant difference in the RL was found between the two models. The RL value was significantly higher 117 for the excision model than that for the tendon retaining model (p=0.004) (Fig. 2). 118 7 DISCUSSION 119 RSA has currently gained popularity in the management of acute PHFs. The present study showed that the 120 supraspinatus tendon isimportant for tuberosity stability in RSA performed for aPHF. This tendon excision121 plays a positive biomechanical role in the stability of tuberosity reconstruction via RSA, especially affecting 122 the stability of the GT-D junction. 123 It is still unclear how tuberosity healing affects functional outcomes after RSA for PHF. In an early report, 124 Cazeneuve et al. [9] excised the remnants of the tuberosities to prevent limitation of adduction and possible 125 instability of the humeral component. Since then, different authors have reported their experience with the126 use of reverse prostheses for fractures. Sebastiá-Forcada et al. [3] reported no differences between 127 tuberosity failure and healing subgroups according to the mean constant score of 31 patients. Chun et al.128 recently reported no differences in functional outcomes regardless of tuberosity healing in 38 patients [14].129 In contrast, Gallinet et al. [12] observed better clinical outcomes of patients with tuberosity healing among130 a group of 41 patients. 131 Given the background, technical efforts have been made to enhance tuberosity healing, and consequently, 132 increased emphasis on tuberosity repair for the restoration of rotational shoulder function has been recently 133 noted [14, 17, 18]. Formaini et al. [11] proposed a hybrid cementation-impaction method with a cancellous 134 bone graft to improve tuberosity healing, and an 88% tuberosity healing rate was reported. In some 135 publications, the description of RSA for a PHF has included supraspinatus resection, but no clinical or 136 biomechanical evidence suggests that this will increase the healing of the tuberosities [2, 12, 14].137 The present study confirmed the involvement of the supraspinatus tendon in GT- and LT-mediated stability 138 of the D in RSA. In the medialized model, resection of the supraspinatus tendon particularly has no effect 139 on GT and LT stability. In the lateralized RSA model, the greater impact of the supraspinatus tendon seems 140 to be focused on GT attachment stability to the D. However, when releasing the supraspinatus tendon, the 141 forces through both tuberosities seemed to increase, contrary to the medialized design. This may be 142 explained because the lateralized glenosphere may produce tension on the subscapularis tendon, 143 infraspinatus tendon and teres minor when the supraspinatus tendon is absent. COR lateralization seems to 144 significantly increase the joint loads, especially when the rotator cuff tendons are repaired [19]. In the 145 lateralization scenario, the rotator cuff tendons may act as antagonists after RSA [20].146 Based on the results obtained, some clinical applications may be advised. The surgeon has the option to 147 either preserve or excise the supraspinatus tendon during the surgery. Preservation of the supraspinatus 148 8 tendon may jeopardize tuberosity stability around the humeral stem in RSA. Reinforcement of the 149 tuberosity sutures may favor bone fragment stability. Hence, the tuberosity stability may be favored when 150 excising the tendon from the GT. When a COR lateralized RSA is performed with a supraspinatus excision, 151 the surgeon must use a higher tension between both tuberosities. Then, the horizontal circumferential 152 fixation suture may play a more important role in tuberosity stability. This effect was previously described 153 by Frankle et al. [15] when studying the tuberosity reattachment stability in proximal humeral 154 hemiarthroplasty. 155 The aim of this study was not to compare the two different RSA techniques. Differences between the 156 designs are not limited to the COR. The authors do not consider the implants employed as comparable 157 designs. Differences include the humeral inclination, humeral stem diaphysis and baseplate diameter. 158 Therefore, a strict comparison of medialized and lateralized implants cannot be performed based on the 159 findings of the present study. Nevertheless, the aim of this study was to analyze the effect of the 160 supraspinatus tendon using two different RSA designs.161 This study has several limitations. First, this is a biomechanical study. The clinical implications cannot be 162 fully determined, as the authors idealized the fracture pattern by obtaining good quality bone fragments and 163 reducing tuberosities with small fracture gaps. Second, cadaveric specimens were used with a mean age 164 and gender distribution that may not represent the target population for RSA treatment due to a complex 165 PHF. Third, the deltoid effect has not been analyzed. Lateralization and rotator cuff repair seem to interact 166 with deltoid action regarding joint load magnitudes [21].167 9 CONCLUSIONS 168 The supraspinatus tendon excision plays a positive biomechanical role in tuberosity stability when 169 performing RSA for treatment of a PHF. Tendon resection leads to a more stable tuberosity construct for 170 both medialized and lateralized RSA models. 171 172 173 174 175 CONFLICT OF INTEREST 176 The authors, their immediate family, and any research foundation with which they are affiliated did not 177 receive any financial payments or other benefits from any commercial entity related to the subject of this 178 article. 179