scieee AI-readable full text Open interactive document viewer

The impact of selected eutectic solvent to biological wastewater treatment plant

Martín Garcia, Marta

Abstract

In the recent years, there has been intensive development of non-hazardous solvents and reaction media, able to replace common organic compounds which are possible aquatic contaminants due to their toxicity, volatility and persistency. As a result, eutectic solvents (ES) were introduced and they are used in different processes (bio-transformations, separation). These eutectic solvents (ES) are generally composed of two or three cheap and safe components that are capable of self-association, to form a eutectic mixture with a melting point lower than that of each individual component. However, they could spread widely by wastewaters and affect large areas in terms of chronic toxicity, bioaccumulation, etc. The benefits and drawbacks of these components are currently being discussed. The biological treatment is often used due to its reliability, simplicity and high cost-effectiveness as well providing many advantages in terms of biodegradable matter and nitrogen compounds removal. However, the efficiency of biological processes is strongly limited because of refractory or inhibitory compounds in wastewaters. Aerobic treatment based on activated sludge process, have been widely studied and adopted. The aim of this research focuses on the determination of the impact caused by the addition of selected ES to the aerobic WWTP. We selected the ES based on choline chloride and malonic acid. First, its toxicity to microorganisms of activated sludge was determined by measurement of inhibition of oxygen consumption of activated sludge. It helped to identify the initial concentration of ES in the influent to the pilot WWTP. The experiment was started with setting up pilot aerobic WWTP, feed by synthetic municipal wastewater and its efficiency was monitored by several parameters. After steady-state operation of WWTP was achieved, the selected amount of ES was added in the influent and treatment efficiency was monitored continuously. The amount of the ES was increased to find the highest concentration of the component still possible to treat in the biological wastewater treatment plant. At the end, it has been seen that although the toxicity of ES to microorganisms was so high, the impact to the biological treatment plant at the same concentrations was negligible, obtaining good treatment efficiency in the pilot WWTP.

Full text

UNIVERSITY OF LJUBLJANA FACULTY OF CHEMISTRY AND CHEMICAL TECHNOLOGY Master study of CHEMICAL ENGINEERING THE IMPACT OF SELECTED EUTECTIC SOLVENT TO BIOLOGICAL WASTEWATER TREATMENT PLANT MASTER THESIS Marta Martín Garcia Mentor: Andreja Žgajnar Gotvajn Ljubljana, February 2014 Declaration I declare that I am the author of the submitted master thesis. Marta Martín Garcia Ljubljana, February, 2014 Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant Content Acknowledgement ................................................................................................... i Abstract.................................................................................................................. ii Symbols ................................................................................................................. iii 1. Introduction ........................................................................................................ 1 2. The aim of the thesis .......................................................................................... 2 3. Theoretical background ...................................................................................... 3 3.1. Definition of Wastewater .............................................................................. 3 3.2. Parameters to determine the quality of water ............................................... 4 3.2.1. Physical parameters .............................................................................. 4 3.2.2. Chemical parameters ............................................................................ 5 3.3. Pollutants in wastewater .............................................................................. 6 3.4. The necessity of wastewater treatment ........................................................ 9 3.5. Historical overview of wastewater treatment ................................................ 9 3.6. Legislative requirements ............................................................................ 10 3.7. Actual situation .......................................................................................... 12 3.8. Biological treatment of WW........................................................................ 14 3.9. WWTP treatment ....................................................................................... 15 3.9.1. Primary treatment ................................................................................ 16 3.9.2. Secondary treatment: biological treatment .......................................... 16 3.9.3. Biodegradation of wastewater ............................................................. 18 3.10. Eutectic solvents ...................................................................................... 20 3.10.1. Definition and structure of Eutectic Solvents ..................................... 20 3.10.2. Use of the Eutectic Solvents .............................................................. 22 4. Experimental .................................................................................................... 24 4.1. Synthesis of selected eutectic solvent ....................................................... 24 4.2. Pilot WWTP ............................................................................................... 26 4.2.1. Description .......................................................................................... 26 4.2.2. Preparation of synthetic wastewater sample ....................................... 27 4.2.3. Daily controlled parameters in WWTP ................................................. 28 4.2.3.1. Temperature ................................................................................. 28 4.2.3.2. Air flow rate................................................................................... 28 4.2.3.3. Wastewater flow rate .................................................................... 28 4.2.3.4. Concentration of dissolved oxygen ............................................... 29 4.2.3.5. Agitation ....................................................................................... 29 Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 4.2.3.6. pH in the influent ........................................................................... 29 4.2.3.7. Control of activated sludge ........................................................... 29 4.2.3.8. Hydraulic retention time (HRT) ..................................................... 30 4.2.3.9. F/M ratio ....................................................................................... 31 4.2.3.10. Treatment Efficiency ................................................................... 32 4.3.1. Toxicity test by activated sludge (ISO 8192, 2007) .............................. 33 4.3.2. Evaluation of ultimate aerobic biodegradability of organic compounds in aqueous medium by determination of oxygen demand in a closed respirometer (ISO 9408, 1989) ...................................................................... 37 4.3.3. Chemical oxygen demand (ISO 6060, 1989) ....................................... 39 4.3.4. Biochemical oxygen demand after n days (ISO 5815/1, 1989) ............ 39 4.4.3. Dissolved organic carbon (ISO 8245, 1989) ........................................ 39 4.3.5. Determination of concentration of nitrite, nitrate, ammonium (APHA, AWWA, WEF, 2005) ..................................................................................... 39 4.3.6. Determination of Chloride (APHA, AWWA, WEF, 2005) ...................... 40 5. Results and Discussion .................................................................................... 41 5.1. Toxicity of eutectic solvent ......................................................................... 41 5.2. Biodegradability of eutectic solvent ............................................................ 48 5.3. Treatment in the WWTP ............................................................................ 50 5.3.1. Daily control of parameters ................................................................. 50 5.3.2. Control of activated sludge .................................................................. 52 5.3.3. Hydraulic Retention time ..................................................................... 54 5.3.4. F/M Ratio ............................................................................................ 55 5.3.5. Treatment efficiency ............................................................................ 56 5.3.6. Biological oxygen demand (BOD5) ...................................................... 58 5.3.7. DOC removal ...................................................................................... 59 5.3.8. Nitrite, nitrate and ammonium concentration ....................................... 60 5.3.9. Concentration of Chloride .................................................................... 61 6. Conclusion ....................................................................................................... 63 7. References ...................................................................................................... 64 Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant i Acknowledgement This master thesis is one of the most important academic challenges that I have been done during my entire career. The opportunity to do the writing of the thesis and work with people from another country during these months was one of the most beautiful experiences in all my life. It would not have possible without all the people that were around me. First, I want to express my eternal gratitude and all my respect to my mentor Assist. Prof. Andreja Žgajnar Gotvajn for all her support and her help. Many thanks for all her advices, corrections and facilities during the writing and the experimental part of this master thesis. Sometimes it was difficult to work in another language and she demonstrates a lot of patience and gave me all the energy to do it. Secondly, I want to express also my eternal thanks to Mrs. Vesna Delalut for all her company in the laboratory and help during these months, above all the first weeks, when everything was new for me and she was helping me with the monitoring of the wastewater treatment plant, chemical oxygen demand and biochemical oxygen demand determinations and also with my stay in Ljubljana. I would like to thank the staff of the faculty of Chemistry and Chemical Technology of University of Ljubljana and also the people who was working with me in the Chair of Chemical, Biochemical and Environmental Engineering. Many thanks to one of my colleagues, Uroš Novak to help me with the synthesis of the selected eutectic solvent (ES) and for all the information about eutectic solvents, something new for me before this research. I want to mention also Nataša Miložič because she was a really good colleague here, and I will be eternal grateful for all her advices and help during my stay in Ljubljana. It was great also to work with Neja Strah, my eternal appreciation to her for all her help with the toxicity test and biodegradability test with ES. I also want to give my eternal grateful to Dr. Gabriela Kalčíková to help me with the determination of nitrite, nitrate and ammonium in the wastewater samples. The greatest thanks go to my parents, because they gave me the opportunity to do my master thesis abroad, they gave me all their support and covered almost all the expenses here. Because I know that they put all of their efforts to enable me to do this experience I want to dedicate this master thesis to them. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant ii Abstract In the recent years, there has been intensive development of non-hazardous solvents and reaction media, able to replace common organic compounds which are possible aquatic contaminants due to their toxicity, volatility and persistency. As a result, eutectic solvents (ES) were introduced and they are used in different processes (bio-transformations, separation). These eutectic solvents (ES) are generally composed of two or three cheap and safe components that are capable of self-association, to form a eutectic mixture with a melting point lower than that of each individual component. However, they could spread widely by wastewaters and affect large areas in terms of chronic toxicity, bioaccumulation, etc. The benefits and drawbacks of these components are currently being discussed. The biological treatment is often used due to its reliability, simplicity and high costeffectiveness as well providing many advantages in terms of biodegradable matter and nitrogen compounds removal. However, the efficiency of biological processes is strongly limited because of refractory or inhibitory compounds in wastewaters. Aerobic treatment based on activated sludge process, have been widely studied and adopted. The aim of this research focuses on the determination of the impact caused by the addition of selected ES to the aerobic WWTP. We selected the ES based on choline chloride and malonic acid. First, its toxicity to microorganisms of activated sludge was determined by measurement of inhibition of oxygen consumption of activated sludge. It helped to identify the initial concentration of ES in the influent to the pilot WWTP. The experiment was started with setting up pilot aerobic WWTP, feed by synthetic municipal wastewater and its efficiency was monitored by several parameters. After steady-state operation of WWTP was achieved, the selected amount of ES was added in the influent and treatment efficiency was monitored continuously. The amount of the ES was increased to find the highest concentration of the component still possible to treat in the biological wastewater treatment plant. At the end, it has been seen that although the toxicity of ES to microorganisms was so high, the impact to the biological treatment plant at the same concentrations was negligible, obtaining good treatment efficiency in the pilot WWTP. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant iii Symbols APHA American Public Health Association AS Activated sludge AWWA American Water Works Association ATU Allylthiourea BOD Biochemical oxygen demand (mg·L -1) BOD5 Biochemical oxygen demand after 5 days (mg·L -1) CAS Chemical Abstracts Service CC Chlorine chloride COD Chemical oxygen demand (mg·L-1) CODIN Chemical oxygen demand in influent (mg·L-1) CODOUT Chemical oxygen demand in effluent (mg·L-1) D Diameter (dm) DCF Dichlorophenol DOC Dissolved organic carbon (mg·L-1) Dt Biodegradation (%) E Treatment efficiency (%) ES Eutectic solvent FAO Food and Agriculture Organization F/M Food to microorganism ratio (kgBOD5·kgAS-1·d-1) H Height (dm) HBD Hydrogen bond donor Het Heterotrophic microorganisms HRAS Hi-Rate activated sludge HRT Hydraulic retention time (h) IC Inorganic carbon (mg·L-1) I Inhibition of oxygen uptake of total microorganisms (%) IH Inhibition of oxygen uptake of heterotrophic microorganisms (%) IL Ionic liquid IN Inhibition of oxygen uptake ok nitrifying microorganisms (%) IN Influent ISO International Organization for Standardization IUPAC International Union of Pure and Applied Chemistry M Metals (mg·L-1) m Mass of activated sludge (g) MA Malonic acid MLTSS Mixed liquor total suspended solids (kg) MO Total microorganisms Nit Nitrifying microorganisms NH4+-N Nitrogen in the form of ammonium (mg·L-1) NO2--N Nitrogen in the form of nitrite (mg·L-1) NO3--N Nitrogen in the form of nitrate (mg·L-1) OCb Oxygen consumption in the blank (mg·L-1) OCs Oxygen consumption in the sample (mg·L-1) OUT Effluent Q Flow of the influent (L·h-1 or m3·h-1) R Oxygen consumption rate in the blank (mg·g-1·h-1) RBC Rotating biological contactor RHA Rate of oxygen uptake for the abiotic control. (with ATU) (mg·g-1·h-1) RHB Rate of oxygen uptake for the blank (with ATU) (mg·g-1·h-1) RHS Rate of oxygen uptake for each sample (with ATU) (mg·g-1·h-1) Rs Specific respiration ratio (mg·g-1·h-1) RTA Rate of oxygen uptake for the abiotic control (no ATU) (mg·g-1·h-1) RTB Rate of oxygen uptake for the blank (no ATU) (mg·g-1·h-1) Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant iv RTS Rate of oxygen uptake for each sample (no ATU) (mg·g-1·h-1). SLR Sludge loading rate (kgBOD5·kgAS-1·d-1) SS Suspended solids (mg·L-1) SVI Sludge volume index (mL·g-1) TDS Total dissolved solids (mg·L-1) TOC Total organic carbon (mg·L-1) TS Total solids (mg·L-1) UK United Kingdom UWWTPs Urban wastewater treatment plants VOC Volatile organic compound (mg·L-1) V Volume of aeration tank (L or m3) Vs Volume of activated sludge sampled. (mL) Vss Volume settled activated sludge (mL) VSS Volatile suspended solids (mg·L-1) VU Sedimentation of activated sludge (mL·L-1) WEF Water Environmental Federation WFD Water Framework Directive WTW Wissenschaftlich-Technische-Werkstätten WW Wastewater WWTP Wastewater treatment plant X Concentration of activated sludge (mg·L-1 or g·L-1) ρ1 Dissolved oxygen concentration in the beginning in the blank (mg·L-1) ρ2 Oxygen concentration at the end of the Blank (mg·L-1). Dissolved oxygen concentration at the end in the blank (mg·L-1) Δt Time interval between two measurements (min) 30minEC50 Conc.(Vol.%) which inhibits oxygen consumption by 50% (in 30min) 30minEC20 Conc. (Vol.%) which inhibits oxygen consumption by 20% (in 30min) M.Martin: The impact of selected eutectic solvent to biological wastewater treatment plant 1 1. Introduction Wastewaters are always a priority issue for the protection of the environment. They could have negative impact to the aquatic biota and human health if they are discharged to the surface water without any treatment. There are many disasters caused by the contamination of the rivers because of the wastewater discharges directly in the aquatic environment, above all if we go back to the 19th century, when population was ignoring consequences of the wastewater discharges. One example could be the rupture of one tank full of activated sludge and wastewater in the Guadiamar river (in Spain), polluting the river with heavy metals such as cadmium, lead, zinc and copper. It affected an area of 4.634 hectares, contaminating 2.703 hectares with activated sludge and 1.931 with acidic water. The river pollution affected cultivation lands and forests. Harvests were no longer suitable for consumption, causing financial problems for farmers in the area. Fishes died and birds too, as a result of the consumption of polluted fish. It took one whole month for the river water to recover to its original state. This occurred in April 25 in 1998 (Lenntech, 2014). However, this is just an example of some disasters related to the untreated water. As a result, wastewater treatment plants appeared on 19th century, being the solution for the removal of the pollutants in wastewater. Nowadays, one of the fundamental part in the wastewater treatment plant (WWTP) is the biological treatment. Most well known systems of wastewater treatment are processes with activated sludge, which removes dissolved organic and inorganic substances, and coagulates colloidal and nonsettled solids (Orhon et al., 2009; Ford, 2009). However, many of these substances can cause some impact to the biological treatment. Scientists are constantly researching new chemical and sometimes these compounds are rapidly available in the market, without almost any environmental impact assessment. Consequently, industries use them for their processes and then generate wastewater that needs to be treated in the WWTP. As a result, this WWTP could be affected and its treatment efficiencies could be reduced. Through this thesis, this situation is reflected, in particular with a selected eutectic solvent (ES), which has been studied for its advantages and drawbacks in some applications. The compatibility of the ES with the biological treatment in the WWTP was studied through toxicity and biodegradability assessment proceeded by simulation study in a pilot WWTP. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 8 Table 2. Conventional characterization of different industrial wastewaters (Orhon et al., 2009). Industrial water Parameter (mg·L-1) Total COD Sol. COD (**) BOD5 Total N NH3- N Total P TSS VSS(*) alkalinity Textile Denim processing 2400 1700 / 35 5.6 34 500 70 530 Polyester knit fabrics 1985 1485 / 27 1.7 9 213 22 960 Cotton knit fabrics 2310 2185 / 24 / 4.5 135 80 / Acrylic processing 1900 1590 / 72 / 4.2 90 43 / Cotton woven fabric 1240 1176 680 144 / 2.2 / / / Yogurt&buttermilk processing 1500 / 1000 63 / 7.2 191 / / Tannery Raw water 4180 1495 / 250 / / 2070 / / Primary effluent 2255 1290 / 215 160 5.9 770 470 1420 Chemical effluent 1090 1035 197 160 1.8 150 55 1140 Meat processing Integrated meat 7230 5500 3180 / 67 3.3 910 850 / Poultry (chicken, turjey, etc) 2690 1700 1595 343 207 30 418 / / (*)VSS: The amount of total suspended solids burned off at 550 ± 50°C (mg·L-1) (CPWA, 2003). (**) Soluble COD: Samples are filtered through a 0.45 mm filter before analysis (Orhon et al., 2009). (/) Data not available. In domestic wastewaters, solids (total, suspended and dissolved solids) are the predominant pollutants. Then, the BOD5 and alkalinity are the following parameters with higher concentration in domestic wastewater. In case of industrial wastewaters, all parameters usually have higher concentrations, in comparison to a typical domestic wastewater. Meat processing wastewaters have the higher concentration of total COD (mg·L-1), BOD5 and N with values of 7230 mg·L-1, 3180 mg·L-1 and 343 mg·L-1, respectively. On the other hand, tannery industry has the higher concentration of total solids, with a value of several thousands in the raw water. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 9 Nitrogen and phosphorus could be presented in low concentration in both industrial and domestic wastewaters. 3.4. The necessity of wastewater treatment Without a wastewater treatment the hazard for the environment, human health and aquatic organisms can be serious. Consequences of the pollution caused by wastewaters are summarized as (USGS Water Science School, 2013): - Degradation of organic matter and debris cause consumption of dissolved oxygen and thus risk for aquatic organisms. - Phosphorus and nitrogen (including ammonia), can cause eutrophication, or over-fertilization of receiving waters, being toxic to aquatic organisms, promote excessive plant growth, reduce available oxygen, harm spawning grounds, alter habitat and lead to a decline in certain species. - Chlorine compounds and inorganic chloramines can be toxic to aquatic invertebrates, algae and fish. - Bacteria, viruses and disease-causing pathogens can pollute beaches and contaminate shellfish populations, leading to restrictions on human recreation, drinking water consumption and shellfish consumption. - Metals, such as mercury, lead, cadmium, chromium and arsenic can have acute and chronic toxic effects on species. - Other substances such as some pharmaceutical and personal care products, primarily entering the environment in wastewater effluents, may also pose threats to human health, aquatic life and wildlife. For such reasons, it is necessary to avoid any contamination of the environment by wastewaters and thus wastewaters have to be treated to remove all these pollutants. Treated wastewater can be then returned back to the watercourse and use again. 3.5. Historical overview of wastewater treatment To know the beginning of the wastewater treatment, we need to go back, in the middle of the 19 century, when the population didn’t know anything about the damage that the polluted water could cause (Anderson, 2009). During that century, several epidemics of waterborne diseases such as cholera and typhoid fever ravaged throughout Europe. The emerging knowledge of the role of microorganisms and sanitary systems for the spreading of diseases resulted in the construction of sewer systems in several large cities. In the final of the 19 century, the vast population increase in urbanized areas lead to severe pollution of rivers and lakes, creating a demand for wastewater treatment (Anderson, 2009). Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 10 First wastewater treatment plant was applied in Europe, consisted mainly of the primary treatment, i.e. screens, grits, strainers and settling tanks. In UK, the leading nation on wastewater treatment in that time, constructed of full-scale biological treatment plant employing biofilm technique (trickling filter), it was operated as early as the 1880 (Anderson, 2009). The secondary treatment was established in Europe during the first half of the 20 century, introducing the activated sludge process. Around 1950, the incentive for wastewater treatment switched from disease prevention to prevention of eutrophication, as the nutrients nitrogen and phosphorus started to attract attention. However, until 1970s tertiary treatment used for nutrient removal was not generally incorporated in the treatment procedure in Europe (Anderson, 2009). Since that moment, the increased amounts of wastewater, stricter discharge regulations and lack of space in urbanized areas in the modernized society accelerate the development of alternative methods for biological wastewater treatment, trying to improve the process, looking for low cost processes with high efficiency and low maintenance (Anderson, 2009). 3.6. Legislative requirements With the development of the industrial processes and technology, the environmental associations started to concern about the amount of wastewater produced and the quantity of discharge from industries without any treatment. Nowadays several legislative requirements exist, with the maximum values and the minimum percentage of reduction for all the pollutants commented before. One of the most important directive accepted to establish common wastewater requirements all over the Europe is called The Water Framework Directive (WFD). It was created to achieve good qualitative and quantitative status of all water bodies and contains information, studies and requirements for drinking water, bathing water, industrial wastewater, agriculture wastewater, etc. (Water Framework Directive, 2014). On 21 May, 1991 the Council Directive 91/271/EEC (Council Directive, 1991) concerning urban wastewater treatment was adopted with the objective to protect the environment from the adverse effects of urban wastewater discharges and discharges from certain industrial sectors. Some of the directive requirements for the urban wastewater treatment plants are presented in the following tables (Table 3, Table 4). Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 11 Table 3: Requirements for discharges from urban water treatment plants subject to articles 4 and 5 of the Council Directive 91/271/CEE of 21 may 1991 (Council Directive, 1991). Parameter Concentration Minimum percentage of reduction (1) Reference method of measurement Biochemical oxygen demand (BOD5 at 20 ºC) without nitrification (2) 25 mg·L-1 O2 70-90 Homogenized, unfiltered, undecanted sample. Determination of dissolved oxygen before and after 5-day incubation at 20 ºC ± 1 ºC, in complete darkness. Addition of a nitrification inhibitor. 40 Under Article 4 (2) Chemical oxygen demand (COD) 125 mg·L-1 O2 75 Homogenized, unfiltered, undecanted sample Potassium dichromate Total suspended solids 35 mg·L-1 (3) 90 (3) - Filtering of a representative sample through a 0.45 µm filter membrane. Drying at 105 ºC and weighing. 35 under Article 4 (2) (more than 10000 p.e.) 90 Under Article 4 (2) (more than 10000 p.e.) 60 under Article 4 (2) (2000-10000 p.e.) 70 under Article 4 (2) (2000-10000 p.e.) - Centrifuging of a representative sample (for at least five minutes with mean acceleration of 2800 to 3200 g), drying at 105 ºC and weighing. (1) Reduction in relation to the load of the influent (2)The parameter can be replaced by another parameter: Total organic carbon (TOC) or Total oxygen demand (TOD) if a relationship can be established between BOD5 and the substitute parameter. (3) This requirement is optional. Analyses concerning discharges from lagooning shall carried out on filtered samples, the concentration of total suspended solids in unfiltered water samples shall not exceed 150 mg·L-1. The minimum percentage of reduction (in relation to the load of the influent) it is 70-90% in case of BOD5, and 75% of COD. Total suspended solids have the strictest requirement, with a 90% of reduction, in relation to the load of the influent. To fulfill these requirements, a really efficient process is needed, that results in treated wastewater with maximum 25 mg·L-1 O2 of BOD5, 175 mg·L-1 O2 of COD, and 35 mg·L-1 of total suspended solids. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 12 In some sensitive areas, where the probability of eutrophication problems is high, a control of nitrogen and phosphorus concentration is required too (Table 4). Table 4. Requirements for discharges from urban wastewater treatment plants to sensitive areas which are subject to eutrophication. One or both parameters may be applied depending on the local situation. The values for concentration or for the percentage of reduction shall apply (Council Directive, 1991). Parameter Concentration Minimum percentage of reduction (1) Reference method of measurement Total phosphorus 2 mg·L-1 (10000- 100000 p.e.) 1 mg·L-1 (more than 100000 p.e.) 80 Molecular absorption spectrophotometry Total nitrogen (2) 15 mg·L-1 (10000- 100000 p.e.) (3) 10 mg·L-1 (more than 100000 p.e.) 70-80 Molecular absorption spectrophotometry (1) Reduction in relation to the load of the influent. (2)Total nitrogen means the sum of Kjeldahl nitrogen (organic and ammonium nitrogen) nitrate-nitrogen and nitrite-nitrogen. (3) Requirements for nitrogen may be checked using daily averages when it is proved. In this case, the daily average must not exceed 20 mg·L-1 of total nitrogen for all the samples when the temperature from the effluent in the biological reactor is superior or equal to 12 ºC. The conditions concerning temperature could be replaced by a limitation on the time of operation to take account of regional climatic conditions. The minimum percentage of reduction (in relation to the load of the influent) is 80% in case of phosphorus and 70-80% for nitrogen. 3.7. Actual situation Currently, industries and population in general are more concerned about the problem of the amount of wastewater generated. In the following figures (Figure 1, Figure 2) the difference in wastewater treatment between 1990 and 2009 in Europe is presented. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 13 Figure 1: Changes in wastewater treatment in Europe between 1990 and 2009. (European Environment Agency (A), 2013). North: Norway, Sweden, Finland and Iceland. Central: Austria, Denmark, England & Wales, Scotland, the Netherlands, Germany, Switzerland, Luxembourg and Ireland. Southern: Cyprus, Greece, France, Malta, Spain and Portugal. East: Czech Republic, Estonia, Hungary, Latvia, Lithuania, Poland, Slovenia, Slovakia. South Eastern: Bulgaria, Romania and Turkey. Wastewater treatment in all parts of Europe has improved during the last 15 to 20 years. Generally, the amount of wastewater collected without treatment is reduced and the use of tertiary treatment increased because of the necessity to obtain water with a high quality or with specific requirements. Figure 1 shows a satisfied evolution in Central, South and East European countries and a good statistics in case of North European countries, with not many changes between 1990 and 2006. On the other hand, countries like Bulgaria, Romania or Turkey were the countries with less evolution in wastewater treatment and the highest ratio of wastewater collected without any treatment. In the Figure 2 the evolution in wastewater treatment in some of the Eastern European countries is discussed separately. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 14 Figure 2: Changes in wastewater treatment in Eastern European countries between 1980 and 2009 (European Environmental Agency (B), 2013). Estonia and Czech Republic were two countries with a satisfying evolution in wastewater treatment. Poland had good statistics too, with a 0% of wastewater collected without treatment. In the opposite side, Slovenia had the highest ratio of untreated water and the worst situation is showed in Slovakia, where the use of secondary and tertiary treatment did not increase. 3.8. Biological treatment of WW It is well known, that the most common way of removal of organic, nitrogen or phosphorus compounds from wastewater are biological processes. It is possible to achieve high elimination efficiency of these pollutants with a relatively low capital and operational costs, in comparison to physicochemical or chemical processes. Wastewater treatment process is a highly complex system with large disturbances, which are controllable with difficulties mainly due to mass and hydraulic load variations. Consequently, it is difficult to maintain the WWTP in a steady state. Biological wastewater treatment, in particular, represents the removal of organic matter in a reactor. During the biological treatment under aerobic conditions, the organic matter is used as a source of food for microorganisms, suspended organics are removed by being enmeshed in the biological activated sludge flocks (biomass), colloidal organics are partially absorbed and entrapped by the activated sludge and a portion of the soluble organics are sorbed by the activated sludge flocks. Consequently, 85% removal of the total COD can be achieved after 10 to 15 minutes of activated sludge-wastewater contact. In addition, a portion of organic compounds (about 50% in term of organic carbon) is oxidized to CO2 and H2O and approximately 60% or energy content in wastewater organics is consumed for Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 15 synthesis of new biomass. The rest (about 40%) represents reaction heat loss (Derco et al., 1999). In the next section (3.9) all the different processes in a wastewater treatment plant are explained with more details. 3.9. WWTP treatment Wastewater treatment plants are usually designated to provide primary, secondary, or advanced treatment, depending on the degree of treatment required (Figure 3). Primary treatment plants utilize physical processes, such as screening and sedimentation, to remove pollutants that will settle, float, or that are too large to pass through simple screening devices. Primary treatment typically removes about 35% of the BOD and 60% of the suspended solids. While the most visibly objectionable substances are removed in primary treatment and some degree of safety is provided, the effluent still has enough BOD to cause oxygen depletion problems and enough nutrients, such as nitrogen and phosphorus, to accelerate eutrophication. In secondary treatment, the physical processes that make up primary treatment are augmented with processes that involve the microbial oxidation of pollutants. When properly designed and operated, secondary treatment removes about 90% of the BOD and 90% of suspended solids. However, typically no more than half of the nitrogen content and one-third of the phosphorus content are removed during secondary treatment. In special circumstances, advanced treatment (previously called tertiary treatment) may be required. This last treatment is varied and specialized, depending on the nature of the pollutants that must be removed (Masters, 1998; Metcalf, 1995). Figure 3. Schematic of a wastewater treatment facility providing primary and secondary treatment using the activated sludge process (Masters, 1998). Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 16 3.9.1. Primary treatment It starts with a simple screening. Screening removes large floating objects that might otherwise damage the pumps or clog small pipes. After that, the wastewater passes into a grit chamber, where it is held for a few minutes. The retention time is chosen to be long enough to allow sand, grit, and another heavy material to settle out but is too short to allow lighter, organic materials to settle. These only heavier materials are usually no offensive and, after washing, can be easily disposed in a landfill (Masters, 1998). When the wastewater leaves the grit chamber, passes to a primary settling tank (sedimentation basin or primary clarifier) where the flow rate is reduced sufficiently to allow most of the suspended solids to settle out by gravity. After a retention time of 3 or 4 hours, 50% to 65% of suspended solids and 25% to 40% of BOD are removed. The solids that settle (primary activated sludge) are removed and scum that floats to the top of the tank (Masters, 1998). 3.9.2. Secondary treatment: biological treatment The main aim of the secondary treatment is to provide additional BOD and suspended solids removal. There are three different commonly used approaches, all of them take advantage of the ability of microorganisms to convert organic matter into stabilized, low energy compounds. Tricking filter (and its variations) and the activated sludge process are carried out after primary treatment, obtaining about 90% of the suspended solids and BOD removal (Masters, 1998). Trickling Filters It was first used in 1892 and consists of a rotating distribution arm, which sprays liquid wastewater over a circular bed of “first size” rocks or other coarse material (Picture 2). Spaces, which contain the air circulation, maintain the aerobic conditions (Masters, 1998). The size of the openings is such that there is no actual filtering taking place, so the name trickling filter is not really an appropriate name. Instead, the individual rocks in the bed are covered by a layer of biological film that absorbs and consumes the pollutants trickling through the bed. This biofilm consists mainly of bacteria, but it can include fungi, algae, protozoa, worms, insect, larvae and snails. The accumulating biofilm periodically slides off individual rocks and is collected at the bottom of the filter, together with the treated wastewater, and passed on to the secondary settling tank, where it is removed. Recycling of the effluent seems to be beneficial, because it enables more effluent organic removal, and it also provides a way to keep the biological biofilm from drying out and then dying during the lowflow conditions (Masters, 1998). Plastic media became popular as a replacement of rocks, because the same volume can be designed to achieve greater surface areas for biofilm growth, and their lightness allows much deeper beds. Sometimes, these filters with plastic materials are called biofilters (Masters, 1998). Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 17 Picture 2. Cross section of a tricking filter (Masters, 1998) Rotating Biological Contactor (RBC) They consist of a series of closely spaced, circular, and plastic disks, which are attached to a rotating horizontal shaft (Picture 3). 40% of each disk is submersed in a tank, which contains the untreated water. The biomass film that grows on the surface of the disks moves into and out of the wastewater as the RBC rotates. While the microorganisms are submerged in the wastewater, they absorb organics; while they are rotated out of the wastewater, they are supplied with needed oxygen (Masters, 1998). Picture 3. RCB cross section (Masters, 1998) Activated Sludge Process It was developed later than trickling filter. With this system, more BOD is removed and it is less sensitive to the temperature changes than the trickling filter. In addition, the design costs are lower. Figure 3 presents the wastewater treatment following this system, called activated sludge process. As indicated before, the biological process is achieved in the aeration tank, which receive effluent from the Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 24 4. Experimental For evaluation of the impact of the selected eutectic solvent (ES) to the activated sludge (AS) in WWTP, function of a pilot WWTP prior and after the addition of ES was monitored. The experimental research included the synthesis of ES, which was based on chlorine chloride (CC) and malonic acid (MA). Then the determination of toxicity to microorganisms of activated sludge was determined, as well as the biodegradability in common environmental condition. Finally simulation of ES removal in WWTP was run in a pilot plant. The pilot experiment started with setting up the pilot aerobic WWTP (V = 7 L) by synthetic municipal wastewater and the efficiency was monitored. The pilot WWTP was monitored by pH, temperature, dissolved oxygen concentration, wastewater flow rate, concentration of the activated sludge in the system, sludge volume index, sedimentation of activated sludge (APHA, AWWA, WPCF, 2005), COD (ISO 6060, 1989), BOD (ISO 5815-1, 2003), TOC (ISO 8245, 1989), etc. After the achievement of the steady-state operation of WWTP, the selected amount of ES was added in the influent and treatment efficiency was monitored continuously. The amount of the ES was increased to find the highest concentration of the component still possible to be treated in the biological wastewater treatment plant. 4.1. Synthesis of selected eutectic solvent The ES is composed from choline chloride with malonic acid in a molar ratio of 1:1. 28.65 g of choline chloride and 21.35 g of malonic acid is needed for the preparation of the sample. The experiment starts with a simple mixing of components at 500 rpm and approximately 70 ºC. When the mixture starts to be liquid, it is possible to increase the rpm to 1000 min-1. The ES solution is ready after 3 or 4 hours and it is a liquid with a high viscosity and a density of 1.232 g·mL-1. The density was measured at 20 ºC with a pycnometer (Capacity of 5 mL; Carl Stuart Co., Leek, UK). Choline chloride is a quaternary amine salt, it dissociates in water into the corresponding positively charged quaternary hydroxyl alkylammonium ion and the negatively charged chloride ion (OECD SIDS, 2004). The structural formula of CC is presented in Figure 4. The main characteristics of CC are described in the Table 7. Figure 4. Structural formula of choline chloride. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 25 Table 7. Main characteristics of choline chloride (CC). CAS Number: 67-48-1 IUPAC Name Ethanaminium, 2-hydroxy-N,N,N-trimethyl-, chloride Molecular formula: C5H14NO.Cl Molecular weight: 139.63 g·mole-1 Melting point: 247 °C Solubility in water (20ºC): 650 g·L-1 CC is also known as non-toxic organic salt, biodegradable and a low cost. It is one of the most common compound to synthesize different eutectic solvents (Abbott, 2014). Some applications of choline chloride based ES are: Electrodeposition of Zinc-tin alloys, synthesis of polyoxometalate based hybrids and preparation of zeolite (Hayyan et al., 2013). Malonic acid is a carboxylic acid (Figure 5). Carboxylic acids donate hydrogen ions if a base is present to accept them. They react in this way with all bases, both organic (for example, the amines) and inorganic. Their reactions with bases, called "neutralizations", are accompanied by the generation of substantial amounts of heat. Neutralization between an acid and a base produces water plus a salt (Chemical Books, 2014). Figure 5. Structural formula of Malonic acid (MA). The main characteristics of MA are described in the Table 8. Table 8. Main characteristics of malonic acid (NCBI, 2014). CAS Number: 144-62-7 IUPAC Name Propanedioic acid Molecular formula: C3H4O4 Molecular weight: 90.03 g·mole-1 Melting point: 189.5 °C Solubility in water (20ºC): 90 g·L-1 Malonic acid is used as building block in chemical synthesis, specifically to introduce the molecular group -CH2-COOH (Chemical Books, 2014). When the eutectic solvent is synthesized, it is characterized by a eutectic temperature of 10 °C (Figure 6). Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 26 Figure 6. Phase diagram for choline chloride/malonic acid (CC/MA) system (Taubert, 2013). ES composed of CC and MA has been shown to be very effective. To mention one example, some recent studies shown that the ES based on CC/MA is effective for the removal of post etch residues, which contains significant amount of cooper based inorganic materials (Taubert e al., 2014). 4.2. Pilot WWTP The principle of the WWTP is based on the biological treatment by activated sludge (chapter 3.9.2). In the next chapter, the description of the pilot WWTP is presented. 4.2.1. Description The pilot wastewater treatment used in this study is presented in Picture 5. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 27 Picture 5. Pilot WWTP, with the different important parts, identified by numbers: 1: Influent tank (synthetic municipal wastewater) 2: Tubes 3: Pump 4: Aeration tank with membrane for separation 5: Effluent (treated wastewater) 6: Digital and analogical temperature and airflow display 7: Flow meter The Influent tank (1) has a capacity of 20 L and contains the synthetic municipal wastewater. When the system works, this wastewater flows through the tube (2) and is transported by the pump (3) to the aeration tank (4). Water flow rate is controlled with the flow meter (7) by an analogical system. The aeration tank contains the activated sludge, which was obtained from the Central Municipal Treatment Plant of Ljubljana City (CČN, Zalog, Ljubljana); it was collected in aeration basin, and transported to the laboratory. This Aeration tank has a capacity of 7 liters. It has a temperature sensor, a membrane inside and the aeration system in the bottom. Good aeration conditions in the reactor are controlled in the digital and analogical temperature and airflow display (6), which shows the air flow rate in L·min-1. When the biological treatment is completed, the effluent (5) leaves the aeration basin through the membrane and goes to the sewage system through a tube. The temperature of the system is controlled digitally (in ºC) (6). 4.2.2. Preparation of synthetic wastewater sample Synthetic wastewater was prepared according to ISO 11733 (ISO 11733, 2004). The Influent tank contained 10 L of municipal synthetic wastewater, which was prepared every day. The composition of the wastewater was: 1) Peptone solution: 0.18 g·L-1 of peptone. It is derived generally from animal liver. It contains vitamins, fat, proteins, amino acids, etc. Basically, the protein is source of carbon for the microorganisms and thus, they can grow up in the reactor. 1 2 4 6 5 3 7 Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 28 2) Inorganic solution: Its function is to introduce the necessary minerals to microorganisms. The composition is described in Table 9. Table 9. Composition of the inorganic solution. Salt Concentration (g·L-1) CON2H4 30 NaCl 7 CaCl2·2H2O 4 MgSO4·7H2O 2 K3PO4 28 3) Tap Water. The WWTP was feed 40 days with this synthetic municipal wastewater to achieve constant operation. Then 0.006 Vol.% of ES was introduced for 8 days, 0.012 Vol.% for 9 days, 0.015 Vol.% for 7 days, 0.020 Vol.% for 6 days and the last concentration added was 0.030 Vol.% for 6 days. 4.2.3. Daily controlled parameters in WWTP 4.2.3.1. Temperature In the reactor, the control of the temperature is very important. It must be constant and between 19 to 22 ºC. This range of temperature is the optimum for the microorganisms to work in an efficient way and reproduce as well. If the temperature reaches more than 37 ºC the microorganisms could not work well and if it is less than 18 ºC, they don't have the optimum conditions for fast growth. It was controlled with a temperature sensor in the reactor. 4.2.3.2. Air flow rate The air flow rate was set up between 1 and 2 L·min-1 to allow transformation of organic matter by organisms and maintain appropriate aerobic conditions (>2 mg·L-1) (Arundel, 2000). 4.2.3.3. Wastewater flow rate The maintenance of a constant wastewater flow rate in the system is important to prevent perturbations in the system (variations in the efficiency, retention time, etc). It was controlled with a flow meter. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 29 4.2.3.4. Concentration of dissolved oxygen To check the aerobic conditions in the reactor it is necessary to measure the concentration of dissolved oxygen in the WWTP. The suitable concentration of dissolved oxygen must be higher than 2 mg·L-1. With these values the microorganisms can develop and perform the biological reactions. This parameter was measured with an oxygen sensor, which converts the measurement of the partial pressure of dissolved oxygen to mg·L-1 through the Henry’s constant implemented in the device. (WTW pH/Oxi 340i) (Arundel, 2000; Doran, 2013). 4.2.3.5. Agitation If there is not an appropriate agitation in the system, the activated sludge starts to settle to the bottom of the reactor. Furthermore, the agitation is important to ensure the good distribution of the oxygen, microorganisms and organic matter in the tank volume. The agitation in WWTP was maintained by the aeration system, which it was analogically controlled (Picture 5). 4.2.3.6. pH in the influent The pH in the influent must be between 6 and 8 (Arundel, 2000). Because of the addition of the selected ES, which contains a strong acid, it was necessary to regularly check this parameter. The pH was checked with pH indicators. 4.2.3.7. Control of activated sludge Concentration of activated sludge It is necessary to maintain appropriate balance between the amount of microorganisms and the quantity of organic matter to treat. The optimum concentration of activated sludge (AS) is approximately 2-3 g·L-1 (Arundel, 2000), and a value lower or higher than the optimum pose problems in aeration and also in the settlement of the AS. The concentration of AS was obtained after filtration of 100 mL of activated sludge (removed from the aeration tank) through filtration paper. Next, filtration paper and activated sludge were dried at 105 ºC for 90 minutes and weighted. [1] X = Concentration of activated sludge (mg·L-1) m = Mass of activated sludge (g) Vs = Volume of activated sludge sampled (mL) Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 30 Sedimentation of activated sludge (VU): Is a parameter for routine control of biological treatment plant using activated sludge. It is based on determination of volume of 1 L of AS settled after 30 minutes. [2] VU = Sedimentation of activated sludge (mL·L-1 ) Vss = Volume settled of activated sludge (mL) Vs = Volume of the activated sludge sampled (1000 mL) Sludge volume index (SVI): Is the volume in milliliters occupied by 1 g of a suspension after 30 minutes of sedimentation. SVI is typically used to monitor settling characteristics of activated sludge and other biological suspensions (APHA, AWWA, WEF, 2005). SVI should be between 50 and 150 mL·g-1 (Arundel, 2000). [3] SVI = Sludge volume index (mL·g-1) VU = Sedimentation of activated sludge (mL·L-1 ) X = Concentration of activated sludge ( g·L-1 ) 4.2.3.8. Hydraulic retention time (HRT) It is the time that the wastewater stays in the biological reactor. It is calculated following the expression (Arnaldos, et al., 2012). Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 31 [4] [5] HRT = Hydraulic retention time (h) V = Volume of the aeration tank (L) Q = Flow of the influent (L·h-1) D = Diameter of the aeration tank (dm) H = Height of the aeration tank (dm) The hydraulic retention time must be long enough to remove the requisite proportion of BOD from the wastewater. In a conventional activated sludge system, the HRT should be between 5 and 14 hours (Davies, 2005). 4.2.3.9. F/M ratio This is the relationship between the load of BOD (or microorganism 'food', in kg·day-1) entering the aeration tank, and the mass of microorganisms in the aeration tank available to treat the incoming BOD. This is therefore known as the Food to Mass ratio (F/M ratio), also often referred to as the Sludge Loading Rate (SLR). F/M ratio = [6] F/M ratio = Food to microorganisms ratio (kgBOD5·kgAS-1·d-1) BOD5 = Biochemical oxygen demand in influent after 5 days (mg·L-1) Q = Flow of the influent (m3·h-1) X = Concentration of the activated sludge (g·L-1) V = Volume of the aeration tank (m3) We determined the F/M ratio considering the chemical oxygen demand in the influent (CODIN) results instead of the BOD5 results, due to the fact that BOD5/COD ratio for the synthetic WW prior to the addition of ES was close to one (very good biodegradability) as well as it stayed close to one after the addition of ES. We estimated that calculation using COD instead of BOD5 was justified. The typical F/M ratios for different biological systems are presented in Table 10. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 32 Table 10: Activated sludge process ranges for F/M ratio control (Lee Mishoe, 1999). Process range names Name type of the WWTP F/M range Extended aeration Extended aeration 0.02-0.07 kgBOD5 · kgMLTSS-1 Sequencing batch reactors Race track or orbital ditch Standard activated sludge Conventional activated sludge 0.11-0.23 kgBOD5 · kgMLTSS-1 Contact stabilization Step aeration Complete (or homogenous) mix Others used with nutrient removal Hi-Rate activated sludge (HRAS) based on desired removal 0.45-4,53 kgBOD5 · kgMLTSS-1 (75 to 69% efficiency) 4.2.3.10. Treatment Efficiency The treatment efficiency is one of the most important general parameters, giving information of the quantity of organic and inorganic matter that is removed from the wastewater. It is determined from the results of the COD, following the expression: E (%) = [7] E = Treatment Efficiency (%) CODIN = Chemical oxygen demand in influent (mg·L-1) CODOUT = Chemical oxygen demand in effluent (mg·L-1) The treatment efficiency can be calculated also by DOC or using BOD5 parameter. For a typical WWTP the BOD removal is expected to be higher than 90% (Arundel, 2000). 4.3. Analytical methods ES characteristics, the efficiency of WWTP and pyshico-chemical parameters of the influent and the effluent in the WWTP were evaluated following the standard procedures. First of all, the toxicity test by activated sludge (ISO 8192, 2007) and the evaluation of aerobic biodegradability of ES in aqueous medium by determination of oxygen demand in a closed respirometer (ISO 9408, 1999) were Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 33 evaluated. Analytical control of influent and effluent and monitoring of the treatment procedures included BOD5 (biochemical oxygen demand (ISO 5815/1, 2003), COD (chemical oxygen demand, ISO 6060, 1989)), DOC (dissolved organic carbon), IC (inorganic carbon) (Shimadzu TOC 5000A Analyzer, 1998, ISO 8245, 1989)) and nitrogen as organic, ammonium (ISO 7150/1, 1984) and nitrate determination. After the addition of ES, the concentration of chloride was also evaluated (APHA, AWWA, WEF, 2005). 4.3.1. Toxicity test by activated sludge (ISO 8192, 2007) In the presence of biodegradable substances, activated sludge (AS) consumes oxygen at a higher rate than in their absence, depending on, among other factors, on concentration of the microorganisms. The addition of a toxic concentration of a test material results in a decrease in the oxygen consumption rate. The measurements of the oxygen consumption are determined with an oxygen sensor and the percentage inhibition of the oxygen consumption should be estimated by comparison of the results of a control mixture containing no test material (Blank test). Two parallel systems with and without N-Allylthiourea (ATU, inhibitor for nitrification process) were carried out. Because experiments are conducted twice, with and without ATU added, the inhibitory effect on oxygen uptake by all activated sludge microorganisms (without ATU added) as well as to heterotrophic microorganisms (with ATU) can be measured (Picture 6). The difference between these two measurements give the nitrification and thus inhibitory effect to nitrifying microorganisms can be also measured. Picture 6. Determination of the toxicity of ES to activated sludge. The test was conducted with different concentrations of ES (0.018 Vol.%, 0.029 Vol.% and 0.040 Vol.%). Another sample with 0.040 Vol.% did not contain activated sludge, to evaluate if the eutectic solvent degraded abiotically. Oxygen consumption rates were measured after 30 minutes of incubation. It was measured for each sample every 30 seconds during 5 minutes. Consistency of activated sludge was assessed in preliminary test with 3,5-dichlorophenol. Concentration of AS was 1500 mg·L-1 (Table 11). Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 40 compound which is analyzed spectrophotometrically at 655 nm (ISO 7150/1, 1984). The Nitrite nitrogen (N-NO2-) is determined through formation of a reddish purple azo dye produced in a acid media, by coupling diazotized sulfanilamide with N-(1- naphtyl)-ethylendiamine dihydrochloride (NED). According to the standard procedure, (APHA, AWWA, WEF, 2005) the measurement of the absorbance is at 543 nm. Nitrate nitrogen (N-NO3-) is reduced to nitrite in the presence of cadmium copper granules in a glass column. The nitrite produced is determined by the same procedure described above. 4.3.6. Determination of Chloride (APHA, AWWA, WEF, 2005) Chloride ion (Cl-) is one of the major inorganic anion contained in wastewaters. Chlorides are titrated with mercuric nitrate because of the formation of soluble, slightly dissociated mercury chloride. In an acid media, diphenylcarbazone indicates the titration endpoint by formation of a purple complex, according to the standard method (APHA, AWWA, WEF, 2005). Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 41 5. Results and Discussion To determine the impact of the selected ES to microorganisms of activated sludge, toxicity and biodegradability tests were conducted. Consequently, simulation of aerobic treatment in pilot aerobic biological WWTP was performed. 5.1. Toxicity of eutectic solvent Toxicity test with 3.5 dichlorophenol confirmed good sensitivity of the activated sludge. 30 minEC50 was in the required range (2-25 mg·L-1) obtaining a value of 3.52 mg·L-1. The activated sludge was suitable for further testing. In Table 17 the results of oxygen concentration for all the samples without ATU are presented. The Oxygen consumption rate in the blank (R) (mg·g-1·h-1) was calculated with the equation [8] and the value obtained was 31.08 mg·g-1·h-1. Then Specific respiration ratio (Rs) (mg·g-1·h-1) was determined with the equation [9] obtaining 20.72 mg·g-1·h-1 (more than 20 mg·g-1·h-1 as requested by ISO 8192, (2007). This confirms appropriate efficiency of the activated sludge used. Table 17. Dissolved oxygen concentration values (mg·L-1) for all the samples in the first test without ATU. Concentration of dissolved oxygen (mg·L-1) Time (min) Blank 0.018 Vol.% 0.029 Vol.% 0.040 Vol.% 0.040 Vol.% abiotic (**) 0.0 8.89 9.44 9.70 9.50 9.95 0.5 8.65 9.29 9.80 9.64 9.97 1.0 8.40 9.16 9.80 9.61 9.99 1.5 8.17 9.03 9.83 9.51 9.99 2.0 7.90 8.91 9.79 9.52 10.01 2.5 7.62 8.78 9.69 9.51 10.01 3.0 7.37 8.65 9.60 9.46 10.01 3.5 7.09 8.51 9.51 9.51 10.01 4.0 6.83 8.38 9.44 9.41 10.01 4.5 6.57 8.28 9.44 9.43 10.02 5.0 6.30 8.16 9.40 9.42 10.02 Slope (RT) (*) 0.5213 0.256 0.0882 0.0345 / (*) RT = Oxygen uptake rate for blank and different concentrations (0.018-0.040 Vol.%) of the ES. (**) No oxygen consumption. ( /) Not determined. In Figure 7 Dissolved oxygen concentration values for total microorganisms (mg·L- 1) were plotted versus time (min) for each sample and the linear trendlines were obtained. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 42 Figure 7. Dissolved oxygen concentration (mg·L-1) in the test with total microorganisms vs. time (min) in the first toxicity test with activated sludge. The oxygen consumption rate was lower when the concentration (Vol.%) of ES was higher, because the microorganisms were affected by the toxicity of ES. As a result, the Inhibition must increase, when the concentration of ES is increased. Inhibition for each sample was calculated following the equation [10]. Next, we represented the Inhibition of oxygen uptake of total microorganisms vs. logarithm of concentration of ES (Vol.%) (Table 18). Table 18. Inhibition of oxygen uptake of total microorganisms and the logarithm of concentration of ES (first toxicity test). Sample Conc. (Vol.%) Log conc. Inhibition, I (%) 0.018 Vol.% 0.018 -1.745 51 0.029 Vol.% 0.029 -1.538 83 0.040 Vol.% 0.040 -1.398 93 The obtained inhibition (%) for each sample was plotted versus logarithm of concentration of the sample (Figure 8) and the 30minEC50 and 30minEC20 values were obtained. y = -0.5213x + 8.9205 y = -0.256x + 9.4209 y = -0.0882x + 9.8568 y = -0.0345x + 9.5882 y = 0.0118x + 9.9695 0 2 4 6 8 10 12 0 2 4 6 Dissolved oxygen concentration in the test with total microorganisms [mg·L-1] Time [min] blank 0.018 Vol.% 0.029 Vol.% 0.040 Vol.% 0.040 Vol.% abiotic Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 43 Figure 8. Inhibition of oxygen uptake of total microorganisms vs. log. of concentration of ES (first toxicity test). With the inhibition results, we saw that at a really low addition of ES, the inhibition was high. That means that the ES was very toxic for the microorganisms, obtaining a value of 93% in the sample with 0.040 Vol.% of ES. 30minEC50 value is the concentration which inhibits the oxygen consumption by 50%. We also calculated 30minEC20, which inhibits the oxygen consumption by 20%, to know the estimated first quantity of ES to add in the WWTP. The 30minEC20 was selected as appropriate value, because 20% of inhibition is usually referred to as the first reliably measured inhibition in toxicity test with activated sludge (Rand, 1995). Using the equation from linear trendline from Figure 8, 30minEC50 and 30minEC20 were calculated. 30minEC50 was 0.017 Vol.% and 30minEC20 was 0.010 Vol%. The test has been done in the same way with ATU to determine the impact of the ES to the heterotrophic microorganisms. In Table 19 the measurement of the dissolved oxygen concentration (mg·L-1) during 5 minutes of the test, for all of the samples, is presented. y = 125.04x + 270.86 R² = 0.9689 0 20 40 60 80 100 120 -2 -1,5 -1 -0,5 0 Inhibition of oxygen uptake of total microorganisms [%] Logarithm of concentration [Vol.%] Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 44 Table 19. Dissolved oxygen concentration values (mg·L-1) and inhibition results for all the samples in the first test with ATU: Concentration of dissolved oxygen (mg·L-1) Time (min) Blank 0.018 Vol.% 0.029 Vol.% 0.040 Vol.% 0.040 Vol.% abiotic (**) 0.0 9.52 9.86 10.53 9.76 10.00 0.5 10.00 9.91 10.51 9.85 10.03 1.0 9.12 9.87 10.49 9.73 10.13 1.5 8.99 9.79 10.47 9.97 10.18 2.0 8.77 9.69 10.45 9.98 10.23 2.5 8.69 9.63 10.43 9.99 10.27 3.0 8.57 9.54 10.42 9.99 10.28 3.5 8.44 9.52 10.40 9.96 10.29 4.0 8.27 9.42 10.38 9.73 10.31 4.5 8.10 9.33 10.36 9.67 10.32 5.0 7.97 9.26 10.35 9.79 10.30 Slope (RH) (*) 0.3491 0.1338 0.0364 0.0105 / (*) RH = Oxygen uptake rate for blank and different concentrations (0.018-0.040 Vol.%) of the ES. (**) See comment in Table 17. (/) Not determined. In Figure 9 dissolved oxygen concentration values in the test with heterotrophic microorganisms (mg·L-1) were plotted versus time (min) for each sample and the linear trendlines were obtained. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 45 Figure 9. Dissolved oxygen concentration in the test with heterotrophic microorganisms (mg·L-1) vs. time (min) in the first toxicity test with activated sludge. The results of the Inhibition of heterotrophic microorganisms (equation [11]) were higher when the concentration of ES was increased. It has been concluded that the ES caused a negative impact to heterotrophic microorganisms. The results of the inhibition of oxygen uptake of heterotrophic microorganism (IH) and the logarithm of concentration of ES are presented below (Table 20). Table 20. Inhibition of oxygen uptake of heterotrophic microorganisms and the logarithm of concentration of ES (first toxicity test). Sample Conc. (Vol.%) Log conc. Inhibition, IH (%) 0.018 Vol.% 0.018 -1.745 62 0.029 Vol.% 0.029 -1.538 90 0.040 Vol.% 0.040 -1.398 97 The obtained inhibition of heterotrophic microorganisms (%) for each sample was plotted versus logarithm of concentration of the sample (Figure 10) and the 30minEC50 values were obtained. y = -0.3491x + 9,64 y = -0.1338x + 9.9545 y = -0.0364x + 10.526 y = -0.0105x + 9.8827 y = 0.0631x + 10.55 0 2 4 6 8 10 12 0 2 4 6 Dissolved oxygen concentration in the test with heterotrophic microorganisms [mg·L-1] Time [min] blank 0.018 Vol.% 0.029 Vol.% 0.040 Vol.% 0.040 Vol.% abiotic Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 46 Figure 10. Inhibition of oxygen uptake of heterotrophic microorganisms vs. log. of concentration of ES (first toxicity test). Using the equation from linear trendline (Figure 10), 30minEC50 and 30minEC20 were calculated. 30minEC50 was 0.0134 mg·L-1 and 30minEC20 was 0.007 mg·L-1. After finishing the characterization of total and heterotrophic microorganisms we calculated the impact to nitrifying microorganisms. IN (%) was calculated with the equation [12], obtaining the results presented, in Table 21. Table 21. Inhibition of oxygen uptake of nitrifying microorganisms and the logarithm of concentration of ES (first toxicity test). Sample Conc. (Vol.%) Log conc. Inhibition, IN (%) 0.018 Vol.% 0.018 -1.745 29 0.029 Vol.% 0.029 -1.538 70 0.040 Vol.% 0.040 -1.398 86 * No reliable measurement of inhibition (%). The obtained inhibition (%) for each sample was plotted versus logarithm of concentration of each sample (Figure 11) and 30minEC50 and 30minEC20 values were obtained. y = 104.36x + 245.56 R² = 0.956 0 20 40 60 80 100 120 -2 -1,5 -1 -0,5 0 Inhibition of oxygen uptake of heterotrophic microorganisms [%] Logarithm of concentration of ES [Vol.%] Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 47 Figure 11. Inhibition of oxygen uptake of nitrifying microorganisms vs. log. of the concentration of ES (first toxicity test). With the results inhibition of nitrifying microorganims, we could see that the inhibition of the heterotrophic microorganisms was higher than for the nitrifying microorganisms. 30minEC50 was 0.023 Vol.% and 30minEC20 value was 0.015 Vol.%. To minimize the experimental error, we decided to run the test twice, obtaining the average values. The oxygen consumption rate in the Blank (R) (mg·g-1·h-1) was calculated again with the equation [8] and the value obtained for this second test was 27.12 mg·g-1·h-1. Then Specific respiration ratio (Rs) (mg·g-1·h-1) was determined again with the equation [9] obtaining 18.08 mg·g-1·h-1 (less than 20 mg·g-1·h-1 as requested by ISO 8192, 2007). The results obtained in the second test could be not reliable due to the lower activity of AS. However, because of the toxicity of 3.5-DCF was in the required range, we assumed that the obtained results could be considered. In Table 22 and Table 23 all results are collected (1st test and 2nd test) for the Inhibition, 30minEC50 and 30minEC20 values for total (Total), heterotrophic (Het) and nitrifying (Nit) microorganisms. y = 166.93x + 322.1 R² = 0.9816 0 20 40 60 80 100 -2 -1,5 -1 -0,5 0 Inhibition of oxygen uptake of nitrifying microorganisms [%] Logarithm of concentration of ES [Vol.%] Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 48 Table 22. Inhibition (%) of oxygen consumption in both toxicity test with the average obtained. Inhibition (%) Conc. (Vol.%) 0.018 0.029 0.040 MO Total Het Nit Total Het Nit Total Het Nit 1st test 51 62 29 83 90 70 93 97 86 2nd test 35 49 20 38 28 / 65 61 70 Avg 43 55 25 33 59 70 79 79 78 (/) Not determined reliable. Table 23. 30minEC20 and 30minEC50 in both tests and the average obtained: 30minEC values (Vol.%) 30minEC20 30minEC50 MO Total Het Nit Total Het Nit 1st test 0.010 0.007 0.015 0.017 0.013 0.023 2nd test 0.013 0.003 0.018 0.031 0.020 0.029 Avg 0.012 0.005 0.017 0.024 0.016 0.026 After both toxicity test carried out we concluded that the selected eutectic solvent was very toxic for the microorganisms, being more toxic for the heterotrophic than for the nitrifying microorganisms. With the 30minEC20 of total microorganisms average value we obtained the first concentration of ES to add in the synthetic wastewater (0.012 Vol.%). To ensure that the ES would not cause a high negative impact in the WWTP we decided to add the 50% of the 30minEC20 value, so the first concentration in the WWTP was 0.006 Vol.%. 5.2. Biodegradability of eutectic solvent The biodegradation of ES was measured each day, during 28 days. In Table 24 the oxygen consumption (mg·L-1) results for ES samples and the blank are presented. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 49 Table 24. Oxygen consumption (mg·L-1) for the blank, ES samples (with and without ATU) and the reference compound. Oxygen Consumption (mg·L-1) Time (Days) Blank (no ATU) Blank (no ATU) Blank avg. (no ATU) ES (no ATU) ES (with ATU) Reference compound 0 0 0 0 0 0 0 1 2 2 2 0 2 14 2 5 5 5 18 20 38 3 14 14 14 48 49 48 4 13 13 13 48 49 48 5 14 13 13 48 49 48 6 13 13 13 48 49 47 7 15 15 15 48 49 48 8 16 16 16 48 49 47 9 17 17 17 48 49 47 10 18 18 18 48 49 48 11 18 18 18 48 49 48 12 18 18 18 48 49 48 13 18 18 18 48 49 48 14 18 18 18 48 49 48 15 18 18 18 48 49 48 16 18 18 18 48 49 48 17 18 18 18 48 49 48 18 18 18 18 48 49 48 19 18 18 18 48 49 48 20 18 18 18 48 49 48 21 18 18 18 48 49 48 22 18 18 18 48 49 48 23 18 18 18 48 49 48 24 18 18 18 48 49 48 25 18 18 18 48 49 48 26 18 18 18 48 49 48 27 18 18 18 48 49 48 28 18 18 18 48 49 48 With the equation [13] we calculated the biodegradation of ES and the reference compound. At the end, biodegradation (%) was represented vs. time (days) (Figure 12). Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 56 Vol.% the conditions in the system changed to Standard Activated Sludge process (F/M between 0.11 and 0.23 kgCOD·kgAS-1·d-1). F/M ratio increased when we added ES but it did not increase linearly because of all the changes in the system (variability of concentration of AS, etc). 5.3.5. Treatment efficiency The COD was one of the most important parameters, because it was used for the monitoring of treatment efficiency. We also calculated the COD of ES, obtaining 1,648,000 mg·L-1 in the first determination and 1,804,000 mg·L-1 for the second time. We obtained an average of 1,726,000 ± 78,000 mg·L-1. The determination of COD was necessary for the biodegradability test and for the estimation of the amount of concentration of ES to add in the WWTP. In Figure 17 the values of COD in Influent (CODIN) and Effluent (CODOUT) before and after the addition of ES are presented. Figure 17. Chemical oxygen demand in influent (IN) and effluent (OUT) of the WWTP with the addition of ES vs. time (days). As the Figure 17 shows, COD in influent (IN) was increasing with the quantity of Eutectic solvent added. The system started with a COD IN between 160 and 250 0 50 100 150 200 250 300 350 400 450 500 0 20 40 60 80 100 Chemical Oxygen Demand [mg·L-1] Time [d] IN without ES IN with 0.006 Vol.% ES IN with 0.012 Vol.% ES IN with 0.015 Vol.% ES IN with 0.020 Vol.% ES IN with 0.030 Vol.% ES OUT without ES OUT with 0.006 Vol.% ES OUT with 0.012 Vol.% ES OUT with 0.015 Vol.% ES OUT with 0.020 Vol.% ES OUT with 0.030 Vol.% ES ES added Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 57 mg·L-1 and it was increasing with the time. The concentration of eutectic solvent was higher every week, with values of 0.006 Vol.% in the beginning, and afterwards was increased to 0.012 Vol.%, 0.015 Vol.% and 0.020 Vol.%. The concentration of 0.030 Vol.% of eutectic solvent was added at the last week of the experimental work, obtaining values of COD of 350-400 mg·L-1. Although the quantity of organic matter to treat was higher every week, the COD in the effluent (CODOUT) did not change significantly, with values between < 5 mg·L-1 and 100 mg ·L-1 as the maximum. Treatment efficiency on the process was calculated (equation [7]) .The COD removal efficiency (%) vs. time (days) is presented in Figure 18. Figure 18. COD removal efficiency (%) in the WWTP with the addition of ES vs. time (days). 90% of BOD removal is the minimum removal considered acceptable in an efficient treatment with AS system (Arundel, 2000). The results, calculated on the basis of COD in this research, were always between 90 and sometimes almost 100%. Just two measurements were less that 90%, with values between 75 and 85%. This was before the addition of ES and the reason could be the same as we explained in the results for dissolved oxygen concentration (chapter 5.3.1), because of the concentration of peptone, that was for a few days 1.5 times higher. The addition of ES did not affect treatment efficiency; it was constant during all experimental work. 0 10 20 30 40 50 60 70 80 90 100 0 20 40 60 80 100 COD removal efficiency [%] Time [d] Without DES 0.006 Vol.% ES 0.012 Vol.% ES 0.015 Vol.% ES 0.020 Vol.% ES 0.030 Vol.% ES ES added Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 58 5.3.6. Biological oxygen demand (BOD5) We analyzed also the Biological oxygen demand after 5 days (BOD5) before and after the addition of ES in the WWTP. The results are shown in Figure 19. Figure 19. Biochemical oxygen demand in influent (IN) and effluent (OUT) of the WWTP with the addition of ES vs. time (days). We started to measure BOD5 after 35 days of the WWTP pilot monitoring. We did not obtained reliable data when we measured this parameter with a concentration of 0.030 Vol.% of ES. As a result, in Figure 19 there are no results for this concentration. The influent values were between 126 mg·L-1 without ES and it increased to 346 mg·L-1 with a concentration of 0.020 Vol.% of ES. With the data obtained we can conclude that BOD5 (mg·L-1) in the influent increased more quickly with the addition of ES than the chemical oxygen demand. However, for the BOD5 in the effluent, the values were always between 2 mg·L-1 and 10 mg·L-1, and there were no difference when we started with the addition of ES. Therefore it can be concluded that ES did not affect BOD5 removal efficiency. 0 50 100 150 200 250 300 350 400 450 0 20 40 60 80 Biochemical oxygen Demand [mg·L-1] Time [d] IN without ES IN with 0.006 Vol.% ES IN with 0.012 Vol.% ES IN with 0.020 Vol.% ES OUT without ES OUT with 0.006 Vol.% ES OUT with 0.012 Vol.% ES OUT with 0.020 Vol.% ES ES added Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 59 5.3.7. DOC removal We started to determine the DOC parameter 35 days after the beginning of the WWTP monitoring. Results obtained in DOC tests are close to the COD results explained before. The DOC in the influent (IN) increased with the time, because of the addition of eutectic solvent. However, DOC in the effluent (OUT) was always low (Figure 20), showing that the efficiency, according to the minimum percentage considered acceptable in an efficient treatment with AS system (Arundel, 2000) for the DOC removal was optimal all the time (Figure 21). Figure 20. Dissolved organic carbon (DOC) in influent (IN) and effluent (OUT) of the WWTP with the addition of ES vs. time (days). For the influent, DOC had values between 150 and 400 mg·L-1, depending on the quantity of ES in the wastewater. COD in effluent (OUT) was always between < 4 and 40 mg·L-1, but there were no difference when eutectic solvent was added. As a result, DOC efficiency shows always values between 80 and 97% (Figure 21). 0 50 100 150 200 250 300 350 400 0 20 40 60 80 100 Dissolved organic carbon [mg·L-1] Time [d] IN without ES IN with 0.006 Vol.% ES IN with 0.012 Vol.% ES IN with 0.015 Vol.% ES IN with 0.020 Vol.% ES IN with 0.030 Vol.% ES OUT without ES OUT with 0.006 Vol.% ES OUT with 0.012 Vol.% ES OUT with 0.015 Vol.% ES OUT with 0.020 Vol.% ES OUT with 0.030 Vol.% ES ES added Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 60 Figure 21. DOC removal efficiency (%) of the WWTP with the addition of ES vs. time (days). 5.3.8. Nitrite, nitrate and ammonium concentration NO4+-N, NO3--N and NO2--N in mg·L-1 were present in influent (synthetic municipal WW) when we started to add ES in the system. We determined all of them three times, for three different concentration of ES (0.015 Vol.%, 0.020 Vol.% and 0.030 Vol.%). In Figure 22 the amount of the nitrogen in these three different forms in the influent and in the effluent vs. the concentration of ES (Vol.%) is presented. 0 10 20 30 40 50 60 70 80 90 100 0 20 40 60 80 100 DOC removal efficiency [%] Time [d] Without ES 0.006 Vol.% ES 0.012 Vol.% ES 0.015 Vol.% ES 0.020 Vol.% ES 0.030 Vol.% ES ES added Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 61 Figure 22. Amount of nitrogen in three different forms in the influent (IN) and the effluent (OUT) of the WWTP vs. the concentration of ES (Vol.%). Concentrations of nitrite in the influent and in the effluent were very low, between 2.5 and 3.4 mg·L-1 for the influent (IN) and 2.3 and 3 mg·L-1 for the effluent (OUT). There was no difference when the concentration of ES was increased. However, nitrate had so much different values when we determined the concentration of nitrate in the effluent, which contained a different concentration of ES. It starts with a value of 0.93 mg·L-1 when the concentration of ES in wastewater was 0.015 Vol.% and it went up to 33 mg·L-1 when the concentration of ES was 0.030 Vol.%. The reason could be that the organic nitrogen, which selected ES contained (Figure 4) started to degrade and peptone added in synthetic municipal wastewater as well. This could be a good hypothesis because the good biodegradability of ES was showed (chapter 5.2). With these concentrations of nitrate in the effluent it has been observed that we need a denitrification process after the treatment in pilot WWTP. With the NH4+-N results, we could ensure a good nitrification process, because the concentration of NH4+-N in the influent was 2.37 mg·L-1 (with 0.015 Vol.% ES), 2.95 mg·L-1 (for 0.020 Vol.% ES) and 3.05 mg·L-1 (for .0.030 Vol.% ES) and it was reduced in the effluent until 1.34 mg·L-1 (for 0.015 Vol.% ES), 0.02 mg·L-1 (for 0.020 Vol.% ES) or less than 0.01 mg·L-1 (for 0.030 Vol.% ES). 5.3.9. Concentration of Chloride High quantity of chloride anion in wastewater could interfere in the biological treatment in a negative way. It is known that high salinity cause cell plasmolysis and death of microorganisms due to the increase of osmotic pressure and reduce the quantity of the filamentous bacteria that play a part in a mechanical integrity 0 5 10 15 20 25 30 35 40 0 0,01 0,02 0,03 0,04 0,05 Concentration [mg·L-1] Concentration of ES [Vol.%] NH4+-N IN NH4+N OUT NO3-N IN NO3-N OUT NO2- N IN NO2- N OUT Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 62 and the structure of the flocks. Recent studies show that protozoans have a limited resistance to salinity shocks and they normally die in 24h with a concentrations of NaCl higher than 40 g·L-1 (Lefebure and Moletta, 2006). For that reason, it was necessary to ensure that the concentration of chloride in the wastewater did not exceed the value. The determination of chloride was done when we added the first concentration of ES in the wastewater (0.006 Vol.%). The concentration of chloride obtained in the influent (IN) was 65 mg·L-1 and in the effluent (OUT) was 35 mg·L-1. Normally when the concentration of chloride in wastewater is less than 10 g·L-1 is considered nonpolluted wastewater (in terms of chloride). Water which passed some clorification processes obtains levels of chlorides between 40 to 63 mg·L-1 (García-Vargas, 2012). We compared these values with our results and we concluded that there were no salinity problems in the pilot WWTP. Although the concentration of ES, which contain Cl- (Figure 4) was increased every week, we considered that it was no necessary to determine the chlorides concentration anymore, because it was so low with a concentration of 0.006 Vol.% and the following concentrations were not so high to assume that we could exceed the concentration of 10 g·L-1. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 63 6. Conclusion Eutectic solvents (ES) are called “green solvents “due to their low price, chemical inertness with water, easy synthesis and biodegradability among other things. However, some recent studies shown that they can be toxic. As a result, they could impact the biological treatment in the WWTP. The selected eutectic solvent in this study was based on choline choride and malonic acid and the following hypotheses were determined. The toxicity of ES was determined by the measurement of inhibition of oxygen consumption of activated sludge (ISO 8192, 2007). We showed that the selected eutectic solvent was very toxic for the microorganisms, being more toxic for the heterotrophic microorganisms than for the nitrifying microorganisms. Therefore, the 1st hypothesis “Eutectic solvent selected is toxic to aerobic microorganisms of activated sludge”, is confirmed. The biodegradation of chlorine chloride-malonic acid ES was tested by the measurement of oxygen consumption in a closed respirometer (ISO 9804, 1999) and we determined that it was degraded more than 70% in 4 days. Therefore, the 2nd hypothesis “ES are biodegradable”, is confirmed. We monitored the pilot WWTP without ES (40 days) and after the addition of ES (33 days) during 77 days. After the addition of ES, the COD, DOC, BOD5 and F/M ratio increased in the influent quickly but the treatment efficiency was higher than 90% during the experiment, the impact on the WWTP was minimal. Therefore, the 3rd hypothesis “ES affects the biological treatment in WWTP” is refused. However, it is important to remark that this hypothesis it is only refused with concentrations from 0.006 Vol.% to 0.030 Vol.% of selected eutectic solvent based on chlorine chloride and malonic acid. As a result, with a higher concentration of the ES, the treatment of the WWTP could be affected and the impact could be different too if the ES tested would be a different compound. At the end, the thesis combines the monitoring of the biological treatment in the WWTP with the addition of the new solvents, called eutectic solvents. I would like to express that the monitoring of the biological treatment in the WWTP requires a complex approach and it can be affected by many factors. Moreover, there are so many different eutectic solvents and it is difficult to define their characteristics in a general term. It is needed to carry on with an intense research to know exactly their effects on a biological treatment in the WWTP. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 64 7. References Abbott, A.: Deep Eutectic solvents. University of Leicester, 2014. Available online (4.1.2014): http://wet.kuleuven.be/english/summerschools/ionicliquids/lectures/abbott.pdf . Anderson, S.: Characterization of Bacterial Biofilms for Wastewater Treatment. Royal Institute of Technology, School of Biotechnology, Stockholm, 2009. APHA, AWWA, WEF: Standard Methods for the Examination of Water and Wastewater, 21st Ed., Washington DC, 2005. AQUASTAT: Aquastat online database: Total water used by country in km3·year-1 according to FAO of the United Nations, 2011. Available online (16.10.2013): http://chartsbin.com/view/1472. Arnaldos, J., Bou, J., Casas, I., Cortina, J.L., Martí, V., De Pablo, J., Pastor, E., Planas, E., Saperas, N., Valderrama C.A.: Tecnologia del medi ambient, ETSEIB, Universitat Politècnica de Catalunya, Barcelona, 2012. Arundel, J.: Sewage and Industrial Effluent Treatment, 2nd Ed., Blackwell Science, London, 2000. Bajc, D.: The impact of eutectic solvents on higher plants. Diploma Thesis, Faculty of Chemistry and Chemical Technology, University of Ljubljana, 2014. (In Slovene). Canadian Public Works Association (CPWA): Wastewater Treatment Plant Optimization, Federation of Canadian Municipalities and National Research Council, Canada, 2003. Chemical Books. Malonic acid, 2010. Available online (8.1.2014): http://www.chemicalbook.com/ChemicalProductProperty_EN_CB9709256.htm. Council Directive 91/271/EEC, 1991, Available online (12.11.2013): http://eur-lex.europa.eu/LexUriServ/site/en/consleg/1991/L/01991L0271- 19980327-en.pdf. Davies, S.P.: The Biological Basis of Wastewater Treatment, Strathkelvin Instruments Ltd, 2005. Derco, J., Kovács, A., Králik, M., Shansab, S.: Modelling of an intermittently aerated completely mixing activated sludge reactor. Mathematical and computer modelling of dynamical systems, 5(4), 1999, 313-336. Doran, P.M.: Bioprocess Enginnering Principles, 2nd Ed., Elsevier, Waltham, 2013. Martin, M.: The impact of selected eutectic solvent to biological wastewater treatment plant 65 European Environmental Agency (A): Changes in wastewater treatment in regions of Europe between 1990 and 2009, 2013. Available online (17.11.2013): http://www.eea.europa.eu/data-and-maps/indicators/urban-waste-water- treatment/urban-waste-water-treatment-assessment-3. European Environmental Agency (B): Changes in wastewater treatment in Eastern European countries between 1980 and 2009. Available online (17.11.2013): http://www.eea.europa.eu/data-and-maps/figures/changes-in-wastewater- treatment-in-countries-of-europe-between-1980s-and-2005-east-3 Falcone, J.: Wastewater Characteristics and Wastewater Sampling. Environmental Services LLC, 2013. Available online (22.10.2013): http://falconeenvironmentalservices.com/Wastewater%20Characteristics%20and% 20Wastewater%20Sampling.htm. Ford, E.: Industrial Water Quality, Fourth edition, Mc Graw Hill, New York, 2009. García-Vargas A., Reyes-Navarrete, M.G.; Alvarado-de la Peña, A.I., González- Valdez, L.S., Magdalena-Antuna, D., Vázquez-Alarcón, E., Estaban-Méndez, M., Quintos-Escalante, M., Herrera-Benavides, A.: Cloruros totales en el agua de abastecimiento, Centro Interdisciplinario de Investigación para el Desarrollo Integral Regional, Instituto Politécnico Nacional, Unidad Durango, México, 2012. Haerens, K., Matthijs, E., Chmielarz, A., Van der Bruggen, B.: The use of ionic liquids based on choline chlorine for metal deposition: A green alternative? Journal of Environmental Management, 90, 2009, 3245-3252. Hayyan, A., Hashim, M.A., Hayyan, M., Mjalli, F.S., AlNashef, I.M.: A new processing route for cleaner production of biodiesel fuel using a choline chloride based deep eutectic solvent, Journal of Cleaner Production, 2013, 1-6. Hayyan, M., Hashim, M.A., Hayyan, A., Al-Saadi, M.A., AlNashef, I.M., Mirghani, M.E.S., Saheed, O.K.: Are deep eutectic solvents benign or toxic?" Chemosphere, 2012. ISO 5813: Water Quality - Determination of dissolved oxygen - Iodometric method, Ed. 1, International Organization for Standardization, Geneva, 1983. ISO 5815-1: Water Quality - Determination of biochemical oxygen demand after n days (BODn) – Part 1. Dilution and seeding method, Ed.1, International Organization for Standardization, Geneva, 2003. ISO 6060: Water Quality - Determination of the chemical oxygen demand, Ed. 2, International Organization for Standardization, Geneva, 1989. ISO 7150-1: Water Quality – Determination of ammonium, Part 1: Manual spectrometric method, Ed.1, Geneva, 1984. ISO 8192: Water Quality- Test for inhibition of oxygen consumption by activated sludge for carbonaceous and ammonium oxidation, Ed.2, International Organization for Standardization, Geneva, 2007.