Emerging organic contaminant removal in a full-scale hybrid 1 constructed wetland system for treatment and reclamation of 2 wastewater in small communities of warm climate regions 3 4 Cristina Ávila1, Isabel Martín2, Carlos Aragón2, Juan José Salas2, Josep M. 5 Bayona3 and Joan García1,* 6 7 1GEMMA-Group of Environmental Engineering and Microbiology, Department of 8 Hydraulic, Maritime and Environmental Engineering, Universitat Politècnica de 9 Catalunya-BarcelonaTech, c/Jordi Girona, 1-3, Building D1, E-08034, Barcelona, Spain 10 2Foundation Centre for New Water Technologies (CENTA). Autovía Sevilla-Huelva 11 (A-49), km. 28. E-41820 Carrión de los Céspedes, Seville, Spain 12 3Department of Environmental Chemistry, IDAEA-CSIC, c/Jordi Girona, 18-26, E-13 08034, Barcelona, Spain 14 15 16 *Corresponding author: Joan García 17 Tel: + 34 93 4016464 18 Fax: +34 93 4017357 19 Email:
[email protected] 20 21
Abstract 22 A full-scale hybrid constructed wetland (CW) system based on three-stages of 23 different wetland configurations showed to be a very robust ecotechnology for 24 wastewater treatment and reuse in small communities. It consisted of a 317-m2 vertical 25 subsurface flow (VF), a 229-m2 horizontal subsurface flow (HF), and a 240-m2 free 26 water surface (FWS) CWs operating in series. An excellent overall treatment 27 performance was exhibited on the elimination of conventional water quality parameters 28 (99% average removal efficiency for TSS, BOD5 and NH4-N), and its final effluent 29 proved to comply with existing guidelines for its reclamation in various reuse 30 applications. The removal of studied emerging contaminants, which included various 31 pharmaceuticals, personal care products and endocrine disruptors, was also very high 32 (average 90 ± 11%), being compound dependent. The high rates were achieved due to 33 the differing existing physico-chemical conditions occurring at different CW 34 configurations, which would allow for the combination and synergy of various 35 abiotic/biotic removal mechanisms to occur (e.g. biodegradation, sorption, 36 volatilization, hydrolysis, photodegradation). While aerobic metabolic pathways and 37 solids retention are enhanced in the VF bed, other removal mechanisms such as 38 anaerobic biodegradation and sorption would predominate in the HF bed. At last, 39 photodegradation through direct sunlight exposure, and less importantly, sorption onto 40 organic matter, seem to take an active part in organic contaminant removal in the FWS 41 wetland. 42 43 Keywords: endocrine disruptor; pharmaceuticals; photodegradation; decentralized 44 wastewater treatment; treatment wetland. 45 46
1. Introduction 47 The occurrence of emerging organic contaminants (EOCs), such as 48 pharmaceutical and personal care products (PPCPs), pesticides or antiseptics in poorly 49 treated wastewater and eventually in other watercourses constitutes nowadays an 50 increasing concern worldwide due to their possible toxicological effects to the 51 environment and living organisms (Daughton, 2005; Cunningham et al., 2006; 52 Kümmerer et al., 2009). Constructed wetlands (CWs) are natural wastewater treatment 53 systems that emphasize the processes happening in natural wetlands so as to improve 54 their treatment capacity (Kadlec and Wallace, 2009). They constitute an alternative 55 cost-effective technology to conventional wastewater treatment plants (WWTPs), 56 especially in the context of small communities with less than 2000 people equivalent 57 (Puigagut et al., 2007). Various types of constructed wetlands have been combined in 58 order to achieve higher treatment efficiency, especially for nitrogen. These hybrid 59 systems are normally comprised of vertical subsurface flow (VF) and horizontal 60 subsurface flow (HF) beds arranged in many possible manners, including recirculation 61 from one stage to another. While in HF wetlands nitrification is not achieved due to a 62 lack of oxygen, in VF aerobic conditions prevail, which provide good conditions for 63 nitrification, but little to negligible denitrification occurs in these systems. 64 Thenceforward, the strengths and weaknesses of each type of system can balance each 65 other out and it in consequence it is possible to obtain an effluent low in total nitrogen 66 concentrations, as well as other pollutants (Cooper, 1999; Vymazal, 2007; Masi and 67 Martinuzzi, 2007). 68 Since EOCs are often poorly removed in conventional WWTPs (Heberer, 2002), 69 advanced water reclamation technologies have been studied (e.g. advanced oxidation, 70 photo-fenton, ozonitzation) (Klavarioti et al., 2009; Rosal et al., 2010). However, these 71
often require a high level of energy consumption and O&M cost, and thus are very 72 unlikely to be implemented in the context of wastewater treatment of small 73 communities. To this regard, several studies have shown a great capacity for EOC 74 removal of constructed wetland systems at full-scale for domestic wastewater treatment 75 of small communities in warm climates. These were conducted at systems consisting of 76 a single wetland configuration at a time, including VF, HF (Matamoros et al., 2009) and 77 FWS (Matamoros et al., 2008b; Llorens et al, 2009). However, studies which evaluate 78 the contribution to EOC removal of different wetland types within a hybrid system 79 through potential synergies in treatment processes are scarce, and include other 80 treatment units (e.g. WWTP, ponds) as a treatment step prior to CWs (Hijosa-Valsero et 81 al., 2010a; Matamoros and Salvadó, 2012). Evaluating the physicochemical properties 82 and behavior of emerging contaminants in different constructed wetland units remain, 83 thus, a future challenge to be developed so as to help in refining CW design and 84 operation modes, which in turn may increase CW acceptance and implementation as a 85 cost-effective and operational alternative to conventional wastewater treatment 86 technologies in decentralized areas (Imfeld et al., 2009). 87 In the context of a collaborative project between the Universitat Politècnica de 88 Catalunya (Barcelona) and the Foundation Centre for New Water Technologies 89 (Seville), aiming at the treatment of wastewater up to quality standards appropriate for 90 reuse through the sole use of CWs, an experimental mesoscale hybrid constructed 91 wetland system aiming at combining different CW configurations (VF, HF and free 92 water surface) showed an excellent performance, both in terms of water quality 93 parameters but also on EOC removal (Ávila et al., 2013a,b). Parallely, a comprehensive 94 approach implemented at full-scale with the same wetland configuration in a 95 Mediterranean climate area of south Spain (Seville) proved to be a highly efficient 96
ecotechnology for an integrated sanitation of small communities in warm climates, 97 holding very low O&M requirements (Ávila et al., 2013d). The treatment technology, 98 which received combined sewer effluent, exhibited a great performance on solids, 99 organic matter and total nitrogen removal, and showed to be very resilient to water flow 100 fluctuations when evaluated during stormy periods and first-flush events. The final 101 effluent of this proved to be of sufficient quality for its further reuse in various 102 applications (i.e. silviculture and irrigation of forests and other green areas non 103 accessible to the public. etc.). 104 However, the disposal into the aquatic environment of emerging contaminants 105 due to incomplete wastewater treatment has been of great concern for more than a 106 decade (Kolpin et al., 2002; Cunningham et al., 2006). Additionally, in recent times 107 there is a clear need to include irrigation as an additional exposure route for chemicals 108 in terrestrial ecosystems. As an example, recent research is being done to explore 109 whether these contaminants can transfer to crop plants irrigated with reclaimed water 110 (Matamoros et al., 2012b; Calderón-Preciado et al., 2013). Although concentrations are 111 low, questions have been raised about the potential impacts of these substances in the 112 environment and animal and public health after long-term exposure (Matamoros et al., 113 2012b). 114 In this scenario, the aim of this study was to evaluate the treatment performance 115 of a full-scale hybrid CW system located in a Mediterranean climate on the elimination 116 of various EOCs from a combined sewer effluent. The selected compounds consisted of 117 various commonly used pharmaceuticals and personal care products (PPCPs), as well as 118 a high-production chemical widely used in epoxy resins lining food and beverage 119 containers. These were: three non-steroidal anti-inflammatory drugs (ibuprofen –IB-, 120 diclofenac –DCF-, acetaminophen –ACE-), three personal care products (tonalide –121
AHTN-, oxybenzone –OXY-, triclosan –TCS-) and two endocrine disrupting 122 compounds (bisphenol A –BPA- and ethynilestradiol –EE2-). 123 124 2. Materials and methods 125 2.1. Pilot-plant description 126 The hybrid treatment system was part of a larger pilot-scale treatment plant 127 (41,000-m2 experimental plant of the Foundation Centre for New Water Technologies, 128 CENTA) that received the wastewater from 2500 PE from the municipality of Carrión 129 de los Céspedes (Seville) together with the runoff collected in a combined sewer 130 system. Pretreatment chambers are common to all technologies in the plant and its 131 effluent is diverted towards each of them. After pretreatment (i.e. screener (2 sieves, 3 132 cm and 3 mm wide), degreaser/desander), the effluent is conveyed towards a pumping 133 chamber, from which the water is distributed through submersible pumps to the 134 different treatment technologies. The constructed wetland system started operation in 135 2005, though the treatment line as it is now began to operate in July 2009. In particular, 136 a hybrid system consisting of a combination of various CW configurations was set in 137 order to balance out the strengths and weaknesses of each type of system. The treatment 138 line consisted of an Imhoff tank followed by a vertical subsurface flow CW (VF), a 139 horizontal subsurface flow constructed wetland (HF) and a free-water surface CW 140 (FWS) connected in series (Fig. 1). 141 The VF wetland had a surface area of 317 m2 and received an average organic 142 loading rate (OLR) of about 9 g BOD5 m-2 d-1 and a hydraulic loading rate (HLR) of 143 0.044 m d-1. It was fed intermittently at about 20 pulses d-1 to an average inflow of 14 144 m3 d-1. The bed consisted of a top layer of 0.05 m of sand (1-2 mm), followed by a 0.6 145 m layer of gravel (4-12 mm) and an underlying 0.15 m stone layer (25-40 mm). Feeding 146
of the VF was done through five lengthwise pipes (diameter = 125 mm) perforated with 147 1 cm diameter holes every 1.8 m distance. Five draining pipes were installed lengthwise 148 at the bottom of the wetland within the 15 cm-thick gravel layer. Every draining pipe 149 had three 1m-tall chimneys so as to provide oxygen transfer into the wetland bed. 150 The HF unit had a surface area of 229 m2 and consisted of a gravel bed of 0.4 m 151 depth (4-12 mm), with an inlet and outlet zone of stones (40-80 mm) to facilitate the 152 flow. Feeding of the bed was done through a 63 mm diameter polyethylene pipe 153 perforated with 1 cm holes every 1 m distance. The outlet of the wetland was done by 154 means of two 125 mm-diameter draining pipes located at the bottom of the stone layer 155 and connected to a flexible pipe, which held the water level 5 cm below the top of the 156 gravel. Both the VF and the HF were planted with Phragmites australis. Vegetation was 157 very well developed at the time of the study. 158 Finally, the FWS had a surface area of 240 m2 and a water depth ranging 10-50 159 cm. A mixture of Typha spp., Scirpus spp., Iris pseudacorus, Carex flacca, Cyperus 160 rutundus and Juncus spp. were planted on a 0.2 m gravel bed. Since the treatment 161 system had been working for several years, it was mature and the vegetation was well 162 developed in all units. The final effluent of the treatment line was collected in an open-163 air water tank with a capacity of 20 m3 so as to store the treated water for its further 164 reuse. Further details on the system can be found in Ávila et al. (2013d). 165 166 2.2. Sampling procedure 167 Sampling was performed twice a week for five consecutive weeks (n = 8) during 168 May and June 2011. Effluent 24-h composite samples of the influent, Imhoff tank, VF, 169 HF and FWS were taken by autosamplers (about 500 mL every 1 h). Grab samples from 170 the water tank were also taken so as to measure the final quality of the stored water. 171
Samples for the evaluation of EOCs were transported to the laboratory in 250 mL amber 172 glass bottles and kept refrigerated at 4ºC until analysis. The sample holding time was 173 less than 24 h. Conventional water quality parameters and studied EOCs were analyzed 174 as described in Section 2.4. Moreover, it should be noted that no rainfall events were 175 recorded two weeks before or during the sampling period. 176 177 2.3. Chemicals 178 Gas chromatography (GC) grade (Suprasolv) hexane, methanol, ethyl acetate 179 and acetone were obtained from Merck (Darmstadt, Germany) and analytical-grade 180 hydrogen chloride was supplied by Panreac (Barcelona, Spain). ENR, SMZ, DC, ETM, 181 LIN, IB, ACE, DCF, AHTN, OXB, BPA, TCS, EE2 and 2,2′-dinitrophenyl were 182 obtained from Sigma-Aldrich (Steinheim, Germany). 2,4,5-trichlorophenoxypropionic 183 acid (2,4,5-TPA) was from Reidel-de-Haen (Seelze, Germany). Trimethylsulfonium 184 hydroxide (TMSH) was supplied by Fluka (Buchs, Switzerland). Strata-X polymeric 185 SPE cartridges (200 mg) were purchased from Phenomenex (Torrance, CA, USA) and 186 the 0.7 µm glass fiber filters of ø = 47 mm were obtained from Whatman (Maidstone, 187 UK). 188 2.4. Analytical methods 189 Onsite measurements of DO, pH and turbidity were taken using a Hach HQ 30d 190 oxymeter, a Hach SensIon i30 pH-meter and a Hach 2100Q turbidity meter, 191 respectively. Water temperature and EC were also measured in situ by using a Hach 192 SensIon i30 thermometer and conductivity meter. Conventional wastewater quality 193 parameters, including TSS and COD were determined by using Standard Methods 194 (APHA, 2001). BOD5 was measured by using a WTW® OxiTop® BOD Measuring 195 System. TN, TP, NH4-N, NOx-N and PO4-P were determined by using a Bran Luebbe 196
AutoAnalyzer 3. Isolation and enumeration of E. coli was made using a Chromogenic 197 Membrane Filtration technique (APHA, 2001). 198 Determination of EOCs in water samples was carried out after samples had been 199 filtered and processed as previously described by Matamoros et al. (2005). The linearity 200 range was from 0.01 to 3 mg L-1. The correlation coefficients (R2) of the calibration 201 curves were always higher than 0.99. The limit of detection (LOD) and limit of 202 quantification (LOQ) were compound dependent in the range from 0.009 to 0.08 µg L-1 203 and 0.02 to 0.27 µg L-1, respectively. 204 205 3. Results and discussion 206 3.1. General water quality parameters 207 Table 1 shows concentrations of the studied water quality parameters along the 208 hybrid CW system. Temperatures were fairly high at the time of the study (24 ± 2 ºC), 209 as expected for the hot summers of the Mediterranean climate of Seville. Indeed, EC 210 values showed to increase as water passed through the FWS and the water tank, which 211 could be explained by the high evapotranspiration taking place at their free water 212 columns. 213 Average overall removal efficiencies achieved in the treatment system up to the 214 water tank were unquestionably high for most water quality parameters (99% TSS, 89% 215 COD, 99% BOD5, 98% NH4-N). These results are in conformity with those obtained by 216 Ávila et al. (2013d) in this treatment plant, after a 1.5-year monitoring period under dry 217 and wet weather conditions, including an intensive sampling campaign during a first-218 flush event. Solids entrapment and organic matter removal was very high within the VF 219 wetland (90 and 91% for TSS and BOD5, respectively). Those values remained low 220 along the treatment system. The elimination of NH4-N was also fairly high within the 221
carbon, nitrogen and other pollutants’ degradation (Zhou et al., 2005; Tietz et al., 2007; 372 Imfeld et al., 2009). However, the synergic nitrification-denitrification activity observed 373 in the VF bed within this study (Section 3.1) suggest the co-existence of both aerobic 374 and anaerobic microenvironments within this wetland bed, which would allow both 375 processes to take place. Similarly, this finding indicates that although aerobic 376 biodegradation and sorption onto organic matter may be the major removal mechanisms 377 contributing to EOCs reduction in VF wetlands, alternative processes based on 378 anaerobic metabolism could simultaneously be occurring at anoxic microsites or 379 micropores within the wetland bed (i.e. in lower layers) (Cooper et al., 1996; Ávila et 380 al., 2010), which contribute to its elimination. Finally, it is worth noting that the large 381 removal rates achieved at this wetland in comparison to the other wetland units are also 382 influenced by the fact that this bed was the first stage of the system, where the major 383 part of the removal would occur (Hijosa Valsero et al. 2010a; Ávila et al., 2013b). 384 385 3.2.3. HF performance 386 Target emerging organic contaminants within the HF bed as a second stage of 387 the hybrid CW system exhibited removal efficiencies, which were best for DCF (24%), 388 AHTN (23%) and BPA (19%) and IB (19%) (Fig. 2). Note that these were not 389 individual efficiencies in respect to the influent of the HF, but the further proportion of 390 elimination in respect to the previous treatment unit (% accum.). The purpose was to 391 ease the comparison of the efficiency of removal within this bed in respect to the other 392 two units. The remaining IB was considerably reduced up to average effluent 393 concentrations of 0.5 ± 0.3 µg L-1. The fragrance AHTN, due to its high hydrophobicity, 394 was moderately removed, presumably by sorption onto the particulate material of the 395 gravel matrix (Carballa et al., 2005; Matamoros and Bayona, 2006). Removal of TCS 396
was extremely poor within this wetland bed (3%), as compared to the VF bed (63%). 397 Similarly low removal efficiencies (<10%) were obtained at the HF bed of the 398 mesoscale hybrid CW system studied by Ávila et al. (2013b). Although TCS has been 399 detected in plant and sediments of a HF CW and its concentration generally decreased 400 from inflow to outflow (Zarate et al., 2012), sorption and plant uptake do not appear to 401 constitute principal mechanism of TCS removal in constructed wetlands. Otherwise, 402 higher degradation rates would have been expected at the HF beds (Singer et al., 2002). 403 The degradation of BPA was only moderate (19%), especially if compared to the 404 reduction rates achieved at the VF (48%) and particularly FWS (33%) wetlands. This 405 would be explained by the occurrence of less energetically-favorable metabolic 406 processes occurring at lower redox conditions, which would result in lower degradation 407 kinetics and hence lower elimination rates (Ávila et al., 2013c). 408 In general, HF wetlands have exhibited lower treatment capacity on the removal 409 of EOCs than VF beds, which could be attributed to the dependence of their 410 transformation processes on a high redox status of the system (Matamoros et al., 2009; 411 Ávila et al., 2013b). However, the treatment performance of HF wetlands has been 412 found to be significantly enhanced in respect to the removal of EOCs (including IB, 413 DCF, or BPA) at experiments at micro, meso and pilot-scale by optimized operation 414 strategies resulting in high redox potentials, such as operating these wetlands in cycles 415 of feed and rest, providing a shallow depth of the water table, or a using a primary 416 treatment based on a conventional settler rather than anaerobic treatments (Matamoros 417 et al., 2005; Song et al., 2009; Ávila et al., 2013c). 418 419 3.2.4. FWS performance 420
The FWS wetland performed especially well for BPA (33%), followed by DCF 421 (20%). The removal of BPA within this wetland was fairly high if compared to the HF 422 unit, which could be explained by enhanced biodegradation of this substance under 423 higher redox and dissolved oxygen conditions within the water column of the FWS (Liu 424 et al., 2009; Ávila et al., 2013c). Sorption onto particulate matter (Stevens-Garmon et 425 al., 2011) and photodegradation (Matamoros et al., 2012a) could further contribute to 426 BPA removal in FWS wetlands. Moreover, the reduction of DCF was in accordance 427 with elimination rates reported by Llorens et al. (2009) at a full-scale FWS wetland 428 receiving secondary effluent. The reduction of DCF was also significantly high (20% 429 accum.) at a mesoscale FWS (Ávila et al., 2013b). These results support 430 photodegradation as a principal removal mechanism involved in DCF reduction in water 431 bodies (Buser et al., 1998; Andreozzi et al., 2003; Matamoros and Salvadó, 2012a, 432 2013; Ávila et al., 2013b), together with less predominant mechanisms (i.e. 433 aerobic/anaerobic biodegradation, plant uptake) (Ávila et al., 2010). Removal of 434 remaining IB took place in this wetland (3%), presumably due to biodegradation since 435 low photodegradation rates are expected for this compound (Yamamoto et al., 2009; 436 Szabó et al., 2011). Although the removal of TCS was negligible (around 4%), some 437 more reduction within the water reuse tank seemed to occur, indicating that 438 photooxidation processes may constitute a small contribution to its removal (Mezcua et 439 al., 2004; Ávila et al., 2013b; Matamoros and Salvadó, 2012, 2013). Additionally, the 440 further reduction of AHTN concentrations within this wetland bed was significant 441 (11%), accumulating an overall removal efficiency of 90%. Although the reduction of 442 AHTN concentrations in the FWS could be attributed to sorption onto particulate matter 443 and sediment, further reduction was achieved at the water reuse tank, suggesting 444 photodegradation through sunlight exposure as one of the principal mechanisms of 445
AHTN’s removal within this type of wetland configuration. Similarly high removal 446 efficiencies were obtained at other FWS wetlands operating as a tertiary treatment step 447 (Matamoros et al., 2008b; Llorens et al., 2009; Matamoros and Salvadó, 2012; Ávila et 448 al., 2013b). 449 450 4. Conclusions 451 A hybrid CW system at full-scale consisting of a combination of CW 452 configurations, which included a vertical flow (VF) CW, a horizontal subsurface flow 453 (HF) CW, and a free water surface (FWS) CWs operating in series, showed to be a very 454 robust ecotechnology for wastewater treatment and reuse in small communities. 455 Excellent overall treatment performance was exhibited on the elimination of 456 conventional water quality parameters (99% average removal efficiency for TSS, BOD5 457 and NH4-N), and its final efflluent proved to comply with existing guidelines for its 458 reclamation in various reuse applications. The elimination of emerging organic 459 contaminants, which included various pharmaceuticals, personal care products and 460 endocrine disruptors, was also very high (90 ± 11%). 461 Most organic matter contaminant removal, as well as the major part of EOC 462 removal took place in the first stage of the treatment system (VF), where aerobic 463 conditions are expected to prevail. The intermittent feeding and unsaturation of the bed 464 constitute key practices in that approach. However, significant denitrification was also 465 found to occur within this wetland bed, suggesting that although aerobic degradation 466 and sorption onto organic matter might constitute the major removal mechanisms 467 contributing to EOCs removal in VFs, alternative processes based on anaerobic 468 microbial metabolism could simultaneously be occurring at anoxic microsites or 469 micropores within the bed, possibly at lower layers. Conversely, a lower removal 470
efficiency was found for the HF bed, where mostly anaerobic degradation and sorption 471 onto the gravel matrix are expected to occur. Finally, photodegradation through direct 472 sunlight exposure and sorption to organic matter seem to take an active part in EOC 473 elimination in FWS wetlands. 474 The combination of different wetland configurations has shown to optimize a 475 number of important treatment processes, achieving an excellent overall EOC reduction, 476 as well as removal of conventional water quality parameters. This has been possible 477 thanks to the occurrence of complementary abiotic/biotic removal pathways taking 478 place under differing physico-chemical conditions existing at wetlands of different 479 configuration. 480 481 5. Acknowledgements 482 This research has been funded by the Spanish Ministry of Environment 483 (MMARM) through the Project No. 085/RN08/03.2. Ms. Cristina Avila kindly 484 acknowledges a predoctoral fellowship from the Universitat Politècnica de Catalunya. 485 BarcelonaTech. The authors would like to express their gratitude to Ramón 486 487 References 488 Andreozzi, R., Marotta, R., Paxéus, N., 2003. Pharmaceuticals in STP effluents and 489 their solar photodegradation in aquatic environment. Chemosphere 50, 1319-490 1330. 491 APHA, 2001. Standard Methods for the Examination of Water and Wastewater. 20th 492 ed. American Public Health Association, Washington, DC, USA. 493
Ávila, C., Garfí, M., García, J., 2013a. Three-stage hybrid constructed wetland system 494 for wastewater treatment and reuse in warm climate regions. Ecological 495 Engineering, in press. At: xxxxxxx. 496 Ávila, C., Matamoros, V., Reyes-Contreras, C., Piña, B., Casado, M., Mita, L., Rivetti, 497 C., Barata, C., García, J., Bayona, J.M., 2013b. Attenuation of emerging 498 contaminants in a hybrid constructed wetland system under different hydraulic 499 loading rates and their associated toxicological effects in wastewater. Science of 500 the Total Environment, submitted. 501 Ávila, C., Pedescoll, A., Matamoros, V., Bayona, J.M., García, J., 2010. Capacity of a 502 horizontal subsurface flow constructed wetland system for the removal of 503 emerging pollutants: an injection experiment. Chemosphere 81, 1137-1142. 504 Ávila, C., Reyes, C., Bayona, J.M., García, J., 2013c. Emerging organic contaminant 505 removal depending on primary treatment and operational strategy in horizontal 506 subsurface flow constructed wetlands: Influence of redox. Water Research 47, 507 315-325. 508 Ávila, C., Salas, J.J., Martín, I., Aragón, C., García, J., 2013d. Integrated treatment of 509 combined sewer wastewater and stormwater in a hybrid constructed wetland 510 system in southern Spain and its further reuse. Ecological Engineering 50, 13-20. 511 Ayaz, S.Ç., Aktas, Ö., Findik, N., Akça, L., Kinaci, C., 2012. Effect of recirculation on 512 nitrogen removal in a hybrid constructed wetland system. Ecological Engineering 513 40, 1-5. 514 Buser, H.-R., Poiger, T., Müller, M.D., 1998. Occurrence and fate of the pharmaceutical 515 drug diclofenac in surface waters: rapid photodegradation in a lake. 516 Environmental Science and Technology 32, 3449-3456. 517
Calderón-Preciado, D., Matamoros, V., Biel, C., Save, R., Bayona, J.M., 2013. Foliar 518 sorption of emerging and priority contaminants under controlled conditions. 519 Journal of Hazardous Materials 260, 176-182. 520 Carballa, M., Omil, F., Lema, J.M., 2005. Removal of cosmetic ingredients and 521 pharmaceuticals in sewage primary treatment. Water Research 39, 4790-4796. 522 Conkle, J.L., White, J.R., Metcalfe, C.D., 2008. Reduction of pharmaceutically active 523 compounds by a lagoon wetland wastewater treatment system in Southeast 524 Louisiana. Chemosphere 73, 1741-1748. 525 Cooper, P.F., Job, G.D., Green, M.B., Shutes, R.B.E., 1996. Reed beds and constructed 526 wetlands for wastewater treatment. WRc Swindon, UK, 184 pp. 527 Cooper, P., 1999. A review of the design and performance of vertical-flow and hybrid 528 reed bed treatment systems. Water Science and Technology 40, 1-9. 529 Cunningham, V.L., Buzby, M., Hutchinson, T., Mastrocco, F., Parke, N., Roden, N., 530 2006. Effects of human pharmaceuticals on aquatic life: next steps. Environ. Sci. 531 Technol. 40, 3456-3462. 532 Daughton, C.G., 2005. "Emerging" chemicals as pollutants in the environment: A 21st 533 century perspective. Renewable Resources Journal 23, 6-23. 534 Heberer, T., 2002. Tracking persistent pharmaceutical residues from municipal sewage 535 to drinking water. J. Hydrol. 266, 175-189. 536 Hijosa-Valsero, M., Matamoros, V., Martín-Villacorta, J., Bécares, E., Bayona, J.M., 537 2010a. Assessment of full-scale natural systems for the removal of PPCPs from 538 wastewater in small communities. Water Research 44, 1429-1439. 539 Hijosa-Valsero, M., Matamoros, V., Sidrach-Cardona, R., Martín-Villacorta, J., 540 Bécares. E., Bayona, J.M., 2010b. Comprehensive assessment of the design 541
configuration of constructed wetlands for the removal of pharmaceuticals and 542 personal care products from urban wastewaters. Water Research 44, 3669-3678. 543 Imfeld, G., Braeckevelt, M., Kuschk, P., Richnow, H.H., 2009. Monitoring and 544 assessing processes of organic chemicals removal in constructed wetlands. 545 Chemosphere 74, 349-362. 546 Kadlec, R.H. and Wallace, S. (eds), 2009. Treatment wetlands, CRC Press, Boca Raton. 547 Klavarioti, M., Mantzavinos, D., Kassinos, D., 2009. Removal of residual 548 pharmaceuticals from aqueous systems by advanced oxidation processes. 549 Environment International 35, 402-417. 550 Kümmerer, K., 2009. The presence of pharmaceuticals in the environment due to human 551 use - present knowledge and future challenges. Journal of Environmental 552 Management 90, 2354-2366. 553 Lishman, L., Smyth, S.A., Sarafin, K., Kleywegt, S., Toito, J., Peart, T., Lee, B., Servos, 554 M., Beland, M., Seto, P., 2006. Occurrence and reductions of pharmaceuticals and 555 personal care proucts and estrogens by municipal wastewater treatment plants in 556 Ontario, Canada. Science of the Total Environment 367, 544-558. 557 Liu, Z., Kanjo, Y., Mizutani, S., 2009. Removal mechanisms for endocrine disrupting 558 compounds (EDCs) in wastewater treatment –physical means, biodegradation, and 559 chemical advanced oxidation: a review. Science of the Total Environment 407, 560 731-748. 561 Llorens, E., Matamoros, V., Domingo, V., Bayona, J.M., García, J., 2009. Water quality 562 improvement in a full-scale tertiary constructed wetland: effects on conventional 563 and specific organic contaminants. Science of the Total Environment 407, 2517-564 2524. 565
Masi, F., Martinuzzi, N., 2007. Constructed wetlands for the Mediterranean countries: 566 hybrid systems for water reuse and sustainable sanitation. Desalination 215, 44-567 55. 568 Matamoros, V., Arias, C., Brix, H., Bayona, J.M., 2009. Preliminary screening of small-569 scale domestic wastewater treatment systems for the removal of pharmaceuticals 570 and personal care products. Water Research 43, 55-62. 571 Matamoros, V., Arias, C., Brix, H., Bayona, J.M., 2007. Removal of pharmaceuticals 572 and personal care products (PPCPs) from urban wastewater in a pilot vertical flow 573 constructed wetland and a sand filter. Environmental Science and Technology 41, 574 8171-8177. 575 Matamoros, V., Arias, C.A., Nguyen, L.X., Salvadó, V., Brix, H., 2012a. Occurrence 576 and behavior of emerging contaminants in surface water and a restored wetland. 577 Chemosphere 88, 1083-1089. 578 Matamoros, V., Bayona, J.M., 2006. Elimination of pharmaceuticals and personal care 579 products in subsurface flow constructed wetlands. Environmental Science and 580 Technology 40, 5811-5816. 581 Matamoros, V., Calderón-Preciado, D., Domínguez, C., Bayona, J.M., 2012b. 582 Analytical procedures for the determination of emerging organic contaminants in 583 plant material: a review. Analytical Chimica Acta 722, 8-20. 584 Matamoros, V., Caselles-Osorio, A., García, J., Bayona, J.M., 2008a. Behaviour of 585 pharmaceutical products and biodegradation intermediates in horizontal 586 subsurface flow constructed wetland. A microcosm experiment. Sci. Total 587 Environ. 394, 171-176. 588
Matamoros, V., García, J., Bayona, J.M., 2005. Behavior of selected pharmaceuticals in 589 subsurface flow constructed wetlands: A pilot-scale study. Environmental Science 590 and Technology 39, 5449-5454. 591 Matamoros, V., García, J., Bayona, J.M., 2008b. Organic micropollutant removal in a 592 full-scale surface flow constructed wetland fed with secondary effluent. Water 593 Research 42, 653-660. 594 Matamoros, V., Salvadó, V., 2012. Evaluation of the seasonal performance of a water 595 reclamation pond-constructed wetland system for removing emerging 596 contaminants. Chemosphere 86, 111-117. 597 Matamoros, V., Salvadó, V., 2013. Evaluation of a coagulation/flocculation-lamellar 598 clarifier and filtration-UV-chlorination reactor for removing emerging 599 contaminants at full-scale wastewater treatment plants in Spain. Journal of 600 Environmental Management 117, 96-102. 601 Mezcua, M., Gómez, M.J., Ferrer, I., Aguera, A., Hernando, M.D., Fernández-Alba, 602 A.R., 2004. Evidence of 2,7/2,8-dibenzodichloro-p-dioxin as a photodegradation 603 product of triclosan in water and wastewater samples. Analytica Chimica Acta 604 524, 241-247. 605 Miège, C., Choubert, J.M., Ribeiro, L., Eusebe, M., Coquery, M., 2009. Fate of 606 pharmaceuticals and personal care products in wastewater treatment plants - 607 Conception of a database and first results. Environmental Pollution 157, 1721-608 1726. 609 Park, N., Vanderford, B.J., Snyder, S.A., Sarp, S., Kim, S.D., Cho, J., 2009. Effective 610 controls of micropollutants included in wastewater effluent using constructed 611 wetlands under anoxic conditions. Ecological Engineering 35, 418-423. 612