Creation of an energy community

Saborit i Codinachs, Laia

Abstract

El context actual en el que els preus de l’energia estan augmentant ràpidament, ha derivat en la necessitat de prendre accions immediates per disminuir la dependència energètica, fet que implica, entre altres mesures, promoure l’autoconsum. D’aquesta manera, es situa al consumidor al centre del sistema, el qual no només consumeix energia sinó que també la genera. Una manera de dur a terme aquest denominat autoconsum, és a través de les comunitats energètiques; un grup de persones, empreses o qualsevol altra entitat que decideix unir-se entre sí, de forma voluntària y organitzant-se per posar en pràctica projectes i activitats amb l’objectiu d’obtenir beneficis socials, econòmics i mediambientals. A partir d’aquí, surt la necessitat d’analitzar la millor manera de desenvolupar aquesta tipologia d’entitats per maximitzar-ne el seu potencial i rendibilitat. Per això, aquest projecte pretén estudiar tota la normativa i marc legat necessari per desenvolupar una comunitat energètica. Començant per la regulació de l’autoconsum compartit, seguint per la diferenciació entre els coeficients estàtics i horaris, i acabant amb la regulació aplicada específicament a la constitució d’una comunitat energètica. Després de comprendre completament el marc legal, aquest projecte culminarà amb al simulació i comparació de tres casos pràctics. L’objectiu és identificar la configuració més eficient per la distribució de l’energia dins d’una comunitat energètica.

Full text

Page 1 Report Treball de Fi de Grau Grau en Tecnologies Industrials i Anàlisi Econòmica CREATION OF AN ENERGY COMMUNITY REPORT Author: Laia Saborit i Codinachs Director: Joaquín Fernández Sánchez Co-supervisor: Enrique Manuel Padilla De La Torre Call: June 2024 Escola Tècnica Superior d’Enginyeria Industrial de Barcelona Page 2 Report Creation of an energy community Page 3 Resum El context actual en el que els preus de l’energia estan augmentant ràpidament, ha derivat en la necessitat de prendre accions immediates per disminuir la dependència energètica, fet que implica, entre altres mesures, promoure l’autoconsum. D’aquesta manera, es situa al consumidor al centre del sistema, el qual no només consumeix energia sinó que també la genera. Una manera de dur a terme aquest denominat autoconsum, és a través de les comunitats energètiques; un grup de persones, empreses o qualsevol altra entitat que decideix unir-se entre sí, de forma voluntària y organitzant-se per posar en pràctica projectes i activitats amb l’objectiu d’obtenir beneficis socials, econòmics i mediambientals. A partir d’aquí, surt la necessitat d’analitzar la millor manera de desenvolupar aquesta tipologia d’entitats per maximitzar-ne el seu potencial i rendibilitat. Per això, aquest projecte pretén estudiar tota la normativa i marc legat necessari per desenvolupar una comunitat energètica. Començant per la regulació de l’autoconsum compartit, seguint per la diferenciació entre els coeficients estàtics i horaris, i acabant amb la regulació aplicada específicament a la constitució d’una comunitat energètica. Després de comprendre completament el marc legal, aquest projecte culminarà amb al simulació i comparació de tres casos pràctics. L’objectiu és identificar la configuració més eficient per la distribució de l’energia dins d’una comunitat energètica. Page 4 Report Resumen El contexto actual en el que los precios de la energía están aumentando rápidamente, ha derivado en la necesidad de tomar acciones inmediatas para disminuir la dependencia energética, lo que implica, entre otras medidas, promover el autoconsumo. De esta forma, se sitúa al consumidor en el centro del sistema, que no sólo consume energía, sino que también la genera. Una forma de llevar a cabo esto que se denomina autoconsumo es a través de las comunidades energéticas, un grupo de personas, empresas o cualquier otra entidad que decide unirse entre sí, de forma voluntaria y organizándose para poner en marcha proyectos y actividades con el fin de obtener beneficios sociales, económicos y medioambientales. A partir de aquí, surge la necesidad de analizar la mejor forma de desarrollar este tipo de entidades para maximizar su potencial y rentabilidad. Para ello, este proyecto pretende estudiar toda la normativa y marco legal necesario para desarrollar una comunidad energética. Empezando por la regulación del autoconsumo compartido, siguiendo por la distinción de los coeficientes de distribución estáticos y horarios y terminando con la regulación aplicada específicamente a la constitución de una comunidad energética. Después de comprender completamente el marco legal, este proyecto culminará con la simulación y comparación de tres casos prácticos. El objetivo es identificar la configuración más eficiente para la distribución de energía dentro de una comunidad energética. Creation of an energy community Page 5 Abstract The current context where energy prices are rapidly increasing has derived to the necessity of taking immediate actions in order to decrease the energy dependence, which involves, among other measures, promoting self-consumption. In this way the consumer is placed at the center of the system who not only consumes energy but also generates it. One way of implementing this called self-consumption is through the energy communities, a group of people, companies or any other entity that decides to join each other, voluntarily and organizing themselves in order to implement projects and activities to obtain social, economic and environmental benefits. From this point on, the need arises to analyze the best way to develop this type of entity in order to maximize its potential and profitability. In order to do so, this project aims to study all the regulations and legal framework needed to develop an energy community. Starting from the shared self-consumption regulation, followed by the distinction of static and hourly distribution coefficients and ending with regulation applied specifically to the constitution of an energy community. After fully understanding the legal framework, this project will culminate with the simulation and comparison of three case studies. The objective is to identify the most efficient configuration for energy distribution within an energy community. Page 6 Report Creation of an energy community Page 7 Table of contents RESUM ____________________________________________________ 3 RESUMEN _________________________________________________ 4 ABSTRACT _________________________________________________ 5 TABLE OF CONTENTS _______________________________________ 7 ABBREVIATIONS AND SYMBOLS ______________________________ 9 LIST OF FIGURES __________________________________________ 11 LIST OF TABLES ___________________________________________ 13 1. INTRODUCTION ________________________________________ 17 1.1. Motivation ................................................................................................. 17 1.2. Prerequisites ............................................................................................ 17 1.3. Objectives ................................................................................................ 17 1.4. Project scope and limitations ................................................................... 18 2. STATE OF THE ART ____________________________________ 19 2.1. Current context of photovoltaic energy .................................................... 19 3. THEORETICAL BACKGROUND ___________________________ 21 3.1. Regulation evolution in the self-consumption sector ................................ 21 3.2. Shared self-consumption ......................................................................... 21 3.2.1. Collective self-consumption ......................................................................... 22 3.2.2. Compensation implementation .................................................................... 23 3.2.3. Comparison between both distribution coefficients ..................................... 24 3.3. Energy communities ................................................................................ 27 3.3.1. Concept of local energy communities (LEC) ............................................... 27 3.3.2. Benefits of EC ............................................................................................. 27 3.3.3. Barriers of EC .............................................................................................. 30 3.3.4. Modality of a community energy without creating a legal entity ................... 31 4. METHODOLOGY AND EQUIPMENT________________________ 32 4.1. Location ................................................................................................... 32 4.2. Photovoltaic production ............................................................................ 34 4.3. Consumptions .......................................................................................... 36 4.3.1. School ......................................................................................................... 36 4.3.2. Football field ................................................................................................ 38 4.3.3. Pavilion ....................................................................................................... 39 4.3.4. Summer pool ............................................................................................... 41 Page 8 Report 4.3.5. Houses ........................................................................................................ 42 4.4. Energy cost .............................................................................................. 45 4.5. Calculations ............................................................................................. 49 5. RESULTS AND DISCUSSION _____________________________ 52 5.1. Case study 1 ............................................................................................ 53 5.2. Case study 2 ............................................................................................ 59 5.3. Case study 3 ............................................................................................ 68 6. RESULTS COMPARISON ________________________________ 78 7. PLANNING ____________________________________________ 83 8. ECONOMIC ASSESSMENT _______________________________ 84 8.1. Project economic assessment ................................................................. 84 8.2. Engineer economic assessment .............................................................. 85 9. ENVIRONMENTAL IMPACT ______________________________ 87 10. SOCIAL AND GENDER EQUALITY ASSESSMENT ____________ 88 11. CONCLUSIONS ________________________________________ 89 12. BIBLIOGRAPHY ________________________________________ 91 Creation of an energy community Page 9 Abbreviations and Symbols IRENA Agencia Internacional de Energías Renovables EC Energy Community LEC Local Energy Community REC Renewable Energy Community CEC Citizen Energy Community EU European Union P2P Peer-to-peer RD Real Decreto PV Photovoltaic PVPC Voluntary Price for Small Consumers IDAE Instituto para la Diversificación y el Ahorro de la Energía VAT Value Added Tax PRTR Plan de Recuperación, Transformación y Resiliencia UNEF Unión Española Fotovoltaica MITECO Ministerio para la Transición Ecológica y el Reto Demográfico ECTS European Credit Transfer and Accumulation System CO2e Equivalent Carbon Dioxide EV Electric Vehicle SO System Operator P&L Profit and Loss statement ROI Return On Investment Page 16 Report Creation of an energy community Page 17 1. Introduction 1.1. Motivation Recently, scientists have tended to stress on the significance of undertaking variations so as to curb environmental problems. It is crucial that we seek viable alternatives for our prevailing energy sources used today. Progressively enhancing daily energy consumption can be best solved by energy communities that are practicable. These communities promote the circular economy and support growth of small and medium sized enterprises enabling them to involve in the development of renewable energy plants. On top of enabling greater utilization of electricity and heat generation they have led to increase energy efficiency levels, created sustainable transportation systems, while saving money too. Energy communities in Spain still have a long way to go in order for them to be considered a viable option for powering a neighborhood. 1.2. Prerequisites To meet the project’s goal, the photovoltaic generation and consumption curves for all the installations are obtained. Later on, an analysis is done to find out any energy distribution patterns or behaviors of interest from these data. After putting them all together and carrying out constant energy distribution and hourly distribution between the public and private installations, results are analyzed and compared between models, leading to conclusions on the most suitable approach for the energy community. Finally, these findings are translated into both economic and environmental terms. 1.3. Objectives The project’s main objective is the creation of an energy community constituted by a town council. Particular objectives are defined below: - Evaluate which is the better way to distribute the energy between their users. - Compare both static distribution coefficients and hourly distribution coefficients, by carrying out a practical example. - Select and analyze the PV production installation and of the consumption profiles. - Achieve and compare a consistent, surplus-minimized distribution of PV energy for a natural year across the town’s installations and private houses, ensuring an even hourly distribution. Page 18 Report 1.4. Project scope and limitations The project involves establishing an energy community for a town council, addressing legal requirements and developing a sustainable model. Maintenance and monitoring of existing solar panels are crucial for optimal performance. Energy distribution will be optimized based on the power generated by the photovoltaic installation and the energy needs of nearby public buildings and private users. Surplus energy will be exchanged among households within 2 km radius and hourly energy distribution will be adjusted to consumption curves and forecasted energy requirements throughout the year. The project faces a first limitation regarding data collection. The annual hourly photovoltaic production is obtained from a real-life installation, so this data is obviously reliable. However, hourly consumption data has been obtained through a simulation software, which provides insights into potential consumption patterns but also introduces uncertainty into planning and optimization processes. This software works with typical consumptions for each kind of installation (house, house + EV, school, football field, etc.). Therefore, even though the data that has been used correspond to some typical consumption, there exists divergences between these profiles and the real ones for the town. It needs to be said that the total annual consumption for each public building does correspond to the real data for each town’s building, so for this part at least this value does reflect the real-life scenario. Therefore, a limitation for this project has been the non-access to real-life consumptions of the town’s buildings, nor the real-life consumptions of the houses and apartments of their habitants. Another limitation is found with the types of installations. The selected installations are a school, a football field, a pavilion and a summer pool. They have been selected as they are some actual buildings that can be found in the town and of which the annual consumption value could be known. However, in the town there are some other public installations that could have been selected and maybe lead to a more optimal result due to their consumption profile. Also, stores or business could have also been considered in the energy distribution and reflect more the town demographic characteristics. The same happens with private residences. The annual consumption has been taken considering average values from other studies, but these may not reflect consumptions in this specific town. Also, the same proportion of houses, houses + EV and apartments has been taken, when this also may not represent the real-life case. Finally, a last limitation is found with the number of case studies. This project has contemplated three case studies. Each case study carries out a different kind of distribution, changing different variables and trying to optimize the previous case. Therefore, many other studies could have been carried out and made different distributions with different criterions, which may have led to a more optimized result than the one obtained. Creation of an energy community Page 19 2. State of the art 2.1. Current context of photovoltaic energy Solar photovoltaic energy is growing in Europe against a backdrop of rapid power sector decarbonization. The current context where prices are rapidly increasing has derived into a huge inflation that has reached top numbers in the last semester of 2022. The war in Ukraine has also worsen this energy situation in Europe, due to a huge dependence on the gas from Russia. This situation reassures the necessity to take immediate actions in order to decrease the energy dependence, which involves, among other measures, promoting the self-consumption. Regarding renewable energies, photovoltaic energy production worldwide has represented 31% of the total generation capacity, according to IRENA data, ranking as the second source behind hydraulic energy. In year 2022, almost 3 times more solar energy than wind energy has been added worldwide. China remains to be the leading global player, with more than 100 GW of installed power in just 2022. However, in this same year, the European Union has achieved the second place overcoming the United States, with an installed power of more than 40 GW, doubling this number with respect to the previous year As can be observed in Figure 1, in 2020, Spain represents a significantly part of the Europe photovoltaic energy, only behind Germany and sharing the second position with the Netherlands and France, approximately. It has to be mentioned that in 2008 a noticeable increase happened, due to the promotion of this kind of energy thanks to different kind of grants. In the following years, there was not that much grants and therefore this translates into the huge decrease in the installation of photovoltaic energy [1]. Figure 1 Evolution of installed PV energy in Europe. (Source: [1]) Page 20 Report As happened in the European context, Spain is also found in a great positive context regarding the photovoltaic energy. Photovoltaic energy continued in 2022 in its leading position in generation technologies installed worldwide, both among renewable and nonrenewable technologies, according to the Annual Report emitted by the UNEF [2]. In the case of Spain, in 2022 records continued to be broken in the solar energy sector. A trail that has continued in 2023, in which the maximum solar generation reached 15,659 MW in May. Represented in Figure 2, 2022 has been the best year for the development of photovoltaic energy in Spain. Actually, 4.701 MW of solar plants have been installed, representing a 30% increase with respect to 2021. On the other hand, self-supply has increased on 108%, reaching the 2.507 MW. The self-supply in industries is the one with the greatest increase, going from 493.2 MW to 1.178,2 MW, which means an increase of 47% in just one year. Figure 2 Evolution of installed and self-consumption PV in Spain. (Source: [3]¡Error! No s e encuentra el origen de la referencia.) Creation of an energy community Page 21 3. Theoretical background 3.1. Regulation evolution in the self-consumption sector Fighting against the rise in electricity prices and promoting the energy transition, in a context where only 14,21% of electricity consumption comes from renewable sources, are crucial objectives promoted by the Ministerio para la Transición Ecológica y el Reto Demográfico [4]. For this reason, with the Real Decreto de 5 de Octubre, 2018 [5] the regulation known as “single tax” was revoked, which posed difficulties in the self-consumption of solar energy by private homes and companies. In this way, it is no longer necessary for installations below 100 kW to be recorded in a specific register. Shortly after this reform, the Real Decreto de 5 de Abril, 2019 [6] (RD 244/2019) was approved, representing a continuation of the previous regulation. This new text allows that the energy surpluses generated in a self-consumption installation can be injected into the network and the user can receive a compensation in the form of a discount on the monthly electricity bill, depending on the amount of energy that it produces and distributes in the network. In addition, the remuneration will be accessible for installations that work from renewable energies with power less than 100 kW, without having to register as producers, greatly facilitating the compensation process. Two years after, the Real Decreto de 21 de Diciembre, 2021 [7] was approved, with the goal of eliminating some legal barriers that hindered the accelerated deployment of electric mobility, self-consumption or innovative renewable energies. The aim of these changes was enabling the efficient and diligent implementation of the funds of the PRTR and the achievement of the objectives set out in the Strategic Energy and Climate Framework. In the mark of the self-consumption, RD 244/2019, is modified, which regulates the administrative, technical and economic conditions for the self-consumption of electric energy, is amended to make collective self-consumption through the grid possible in those cases in which generation and consumption are connected at a distance of less than 500 meters regardless of the voltage level at which they are connected. Finally, Real Decreto de 27 de Diciembre, 2022 [8] increases this distance to 2 km. 3.2. Shared self-consumption As it is explained in Annex 1, section 1.1 of Real Decreto-ley 244/2019 de 5 de abril, Artículo 4, the following modalities can be found in the legal framework: Page 22 Report • Self-consumption supply modality without surpluses. • Self-consumption supply modality with surpluses. o Surplus modality with economic compensation. o Surplus modality without economic compensation. All the characteristics for each of them is largely described in Annex I. For the case of this project, surplus modality with economic compensation will be developed. This model allows to both supply energy for self-consumption and inject surplus energy into the distribution network. The most important characteristic of this modality is that the total installed power of the associated production facilities cannot exceed 100 kW. This will be taken into consideration when choosing the generation installation. Another aspect that has been taken into account and that it is explained in Annex 1, section 1.2 of Real Decreto-ley 20/2022 de 27 de diciembre, is that this regulation modifies the maximum distance between consumers and the PV installation established in RD 244/2019. This distance is incremented from 500 meters to 2 km. 3.2.1. Collective self-consumption A consumer is considered to participate in a collective self-consumption when they are part of a group of consumers who, by mutual agreement, share electric energy produced by nearby facilities associated with their consumption. When implementing this kind of self-consumption, it is needed to go through some phases that requires time, as it is a very important social factor. Firstly, it is needed that all the people taking part in the project reaches an agreement, meaning the obligation of taking part in the project inversion and the right to obtain the agreed portion of the generated energy. Also, to obtain the corresponding compensation of the electric bill depending on the surplus injection. The administration process to register and put into operation a self-consumption installation has been significantly simplified, even though there still are some compulsory steps to be followed. One of these simplifications is given for the installations of less than 15 kW that are found in urban land and that have the facilities and services required by urban planning legislation. If all these characteristics are met, it is not needed to ask for access permission and network connection, so no guarantee nor collateral will be required for the connection of the installation to the electrical grid. The current collective self-consumption regulation, considers two types of energy distribution coefficients: static distribution coefficients and hourly static distribution coefficients. Annex 1, section 1.1 of Real Decreto-ley 244/2019 de 5 de abril, Anexo I, stablishes that these distribution coefficients have to be fixed for any time of the year. The members of the community could freely agree on how to distribute the energy produced, but maintaining Creation of an energy community Page 23 the same distribution coefficients throughout the year. This implies a fixed distribution of energy that leads to the generation of many surpluses. On the other hand, Annex 1, section 1.3 CNMC, Informe sobre el Proyecto de orden por la que se modifica el Anexo I del Real Decreto-ley 2844/2019, de 5 de abril, para la implementación de coeficientes de reparto dinámicos en autoconsumo colectivo, provides the possibility of implementing fixed but different distribution coefficients for each hour of the day. Users can agree to vary the percentages in which energy is distributed according to the time of consumption. These coefficients can be fixed for a maximum of 20 years, but there is the possibility of modifying them with the agreement of all consumers. However, this modification can only be made at intervals of no less than one year. This is because it is not an automatic change. In order to make this change, a series of actions such as closing measurement and additional billings must be carried out. The aim of this change is to achieve a more flexible distribution of energy, as well as favor a better use of the produced energy, which translates in a reduction of surpluses. As one of the secondary objectives of this project, both ways of distributing the generated PV energy will be compared, so that conclusions can be extracted. 3.2.2. Compensation implementation The methodology followed in order to stablish the compensation mechanism between the consumers and the producer, which includes all the facilities eligible for compensation (even those that do not have surpluses, being only required the power sharing contract in this case), is defined in the Guía de Tramitación del Autoconsumo redacted by the Insitituto para la Diversificación y ahorro de la Energía (IDAE) [9]: Surplus compensation contract All the users participating in the collective self-consumption have to choose the criterion for distributing the self-generated energy between them, and communicate this decision to the distribution company, either directly or through the marketing company, requesting the application of this criterion. This criterion has to be chosen by all the users as they find fitted, so that the coefficients (static or dynamic) are previously fixed during all the billing period and sum up to 1. In case there is only one consumer, this coefficient will be 1. If there is no notification of any understanding, the used criterion will be the one stablished in Annex 1, section 1.1 of Real Decreto-ley 244/2019 de 5 de abril, Anexo I. Simplified compensation mechanism The surplus energy that the installation injects into the distribution network will be valued at a certain price and will be subtracted each month from the acquired energy of the network. Page 24 Report 3.2.3. Comparison between both distribution coefficients In order to observe how these coefficients are reflected in a real-case scenario, a quick study has been carried out, using real data. This will help to comprehend the theoretical benefits of applying hourly distribution coefficients. To do so, a comparison has been made between the two models, using the photovoltaic production curve of a real school (and which will be used during all the project), whose name and location remains anonymous for confidentiality matters. The nominal installed power of the school is 90 kWn. Also, three profiles of public buildings with typical consumptions have been chosen, concretely school, a library and an outside public pool, meaning it is working on summer. These consumption profiles have been obtained using an excel tool where all the data can be entered and it returns a typical annual consumption of the selected equipment. This will be shown in more detail in section 4. The following list shows the characteristics of the selected consumptions profiles. It shows the annual consumption (kWh/year) and the weight each consumption has on the overall consumption of the three buildings (%). • School: 30.000 kWh/year, 19% with respect to the global consumption. • Library: 150.000 kWh/year, 62% with respect to the global consumption. • Pool: 35.900 kWh/year, 19% with respect to the global consumption. These percentages represent the distribution that would be made in the case of static distribution coefficients, as they are always done considering the participation of each user in the overall consumption, and assigning the corresponding percentage depending on their contribution. It must be taken into account, that this quick study has been done for the 13th of September, as it is a day in which the three installations are opened and working. Obviously, the results will be different for each day of the year, but the goal of this section is just to graphically represent the benefits of introducing the hourly distribution in front of the static one. Carrying out this same analysis for any other working or weekend day in order to see if there is some sort of pattern could be an extension of this project. Once these results have been obtained, an optimization procedure has been carried out in order to obtain an hourly static distribution, so that the surpluses can be reduced. The graphical and numerical results are explained in both Figures 3 and 4 and Table 1, respectively. Creation of an energy community Page 25 First of all, in order to interpret both Figure 3 and 4, it is essential to understand what represents each line and column. The three lines (blue, yellow and green) represent each equipment consumption. As was seen in the previous list, the pool is the equipment with the highest consumption, as it is seen in the graph, with a consumption curve quite above the other ones. The columns (blue, yellow and green), represent the photovoltaic production assigned to each equipment, following the weight each equipment has on the overall consumption. Equipment’s with less consumption are assigned less PV production, and otherwise. It is also important to note that for each equipment (for instance, blue line and blue column for the pool), the parts of the column above the line correspond to surpluses. Looking at Figure 3 representing the PV production distribution with static coefficients, it can be seen that columns referring to the pool are bigger than the ones corresponding to the other two equipment’s. That is due to its contribution to the overall consumption, as previously stated. Also, can be observed that in this case plenty of surpluses are generated, since the energy distribution does not take into account hourly behavior. The other remaining equipment’s do not generate many surpluses, but also have a lower percentage of self-consumption. Figure 3 PV distribution with static distribution coefficients. (Source: [Own]) Figure 4 PV distribution with hourly static coefficients. (Source: [Own]) Page 32 Report 4. Methodology and equipment Regarding the methodology followed in this project, the first step has been the research and initial theoretical study of all the concepts that needs to be taken into account for the creation of the LEC, as well as the legal regulation that is nowadays defining all these concepts. This study is all that has been seen up to this point with all the details included in Annex I. After understanding everything that wraps around the concept of energy communities, the aim of this chapter is to put into practice the implementation and energy management between the production coming from the PV installation and the electrical consumption of the members of a potential energy community. Therefore, this section will proceed to study different possibilities in which the energy community could be implemented. 4.1. Location The energy community implementation has been proposed to be on a place where different types of consumers could be analyzed: both homes and public buildings. With this consumption variations a more accurate and real study will be carried out, as it will allow to replicate real-life scenarios in which an energy community could be implemented. The photovoltaic generation data has been obtained from a real PV installation from a town of approximately 2.300 habitants (2018), whose name will not be mentioned due to confidentiality matters. This generation data corresponds to a public school regulated by the Town Council. This PV installation is now self-consuming the generated energy together with other public installations, which leads to lots of surpluses. As it will be an energy community based on shared self-consumption, since it is the unique way contemplated by law, the configuration of the energy community will contemplate a maximum radius of 2 km between the PV installation and the associated consumers. Also, the installation must have a maximum installed power of 100 kW in order to compensate their surpluses. Figure 5 represents the population center of the municipality, in other words, the region where concentrates the majority of the habitants. It can be observed the location of the two PV installations together with the 2 km supply radius of these installations. As can also be seen, there is a part of the population who cannot be supplied with the current installations, so a future proposition for the project could be the placing of another PV installation in that region, able to supply all those people. Nevertheless, for now we will be centered on the region where the school PV installations is placed. Creation of an energy community Page 33 The projected photovoltaic field of the school is on the roof, it consists of 239 modules of 420 Wp, with a total peak power of 90,4 kWp. Of these, 156 of the modules are installed on the south roof of the school and the remaining 83, on the roof of the Nursery School. Finally, this installation has a nominal power of 90 kWn, which will eventually be distributed between the different buildings. This information is of interest since when carrying out the study for the distribution of the photovoltaic energy it will be essential to know the nominal photovoltaic power of the installation. Then, this will help to see how many installations can be supplied and compute the most optimized distribution, between public and private buildings, as well as how many habitants would benefit from this energy. Figure 5 Geographic view of the PV installation on the municipality. (Source: [13]) Page 34 Report 4.2. Photovoltaic production Once the photovoltaic installation has been defined, let’s now observe its photovoltaic generation along a natural year. In order to be able to represent the data for 1 year, an average day has been computed. However, it is important to take into account that for future computations the overall data for the whole year will be used. In the following table, this data can be observed. Obviously, the photovoltaic generation occurs during those hours of the day where there is sun, reason why at both early morning and late-night hours there is 0 generation. Differences in generation throughout the year can be explained by the intensity of solar radiation or the presence of shadows, such as those cast by a tree, which may lead to reduced production. Hour Daily average generated hourly energy for 1 natural year (kWh) 0 0 1 0 2 0 3 0 4 0 5 0,001255357 6 0,371804474 7 2,791347554 8 9,156740425 9 20,24903284 10 33,65988316 11 44,55456685 12 51,58573369 13 54,39267438 14 53,77337478 15 47,73141068 16 37,57976578 17 24,42700666 18 12,38192709 19 4,804582457 20 0,891257389 21 0,001275806 22 0 23 0 Table 2 Daily average generated hourly energy for a natural year for both installations. (Source: [Own]) Creation of an energy community Page 35 Also, this data has been represented to observe the production curve for the equipment. Taking advantage of the PVSyst program, and after carrying out a simulation for the installation, the following data has been obtained. The simulation data is summarized in Table 3 and the monthly data production is collected in Table 4 and it is then plotted in Figure 7. School Data Value Annual generated energy 145.136,29 kWh/year Annual specific energy 1.445 kWh/kWp·year Performance 84,51% Table 3 Energy summary for the school PV installation. (Source: [Own]) Month Effective energy (kWh) January 6.814,23 February 9.100,32 March 12.761,24 April 14.371,13 May 16.597,15 June 17.285,97 July 17.796,46 August 16.264,44 September 12.435,08 October 9.581,40 November 6.686,89 0 10 20 30 40 50 60 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Production (kWh) Daily average PV generated hourly energy for 1 natural year School PV generated energy Figure 6 Representation of the average generated PV energy in one day. (Source: [Own]) Page 36 Report December 6.089,27 Total 145.783,58 Table 4 Monthly generated PV energy for the school installation. (Source: [Own]) 4.3. Consumptions In this section the different consumers constituting the energy community will be exposed and analyzed. For the school, the overall value for the annual consumption is known from bills provided by the Town Council. However, access to the charge’s curves was not possible, so an alternative had to be searched. Finally, an excel tool to simulate typical consumptions has been used. In order to generate these profile consumptions, the annual consumption of the equipment is needed, and the profiles already created simulates a typical consumption for the selected equipment. For this reason, a limitation for this project is the reliability of the consumption data, as it is not real-life data, but simulated data. 4.3.1. School For the school, an annual consumption of 33.029 kWh has been selected, after checking the energy bills for a natural year. It must be taken into account that the town where the energy community is being constituted has 2.300 habitants, as stated before, meaning that it is a small town. For this reason, the school is also proportional, meaning that it is not a really big building. Entering this data to the tool mentioned before, the monthly consumption is seen in Table 5 has been obtained and afterwards represented in Figure 8. 0 2.000 4.000 6.000 8.000 10.000 12.000 14.000 16.000 18.000 20.000 Production (kWh) PV school production Figure 7 Representation of the monthly PV generation. (Source: [Own]) Creation of an energy community Page 37 Month Consumption (kWh) January 3.444,67 February 3.047,63 March 2.824,99 April 2.811,41 May 2.998,67 June 2.664,53 July 1.986,25 August 1.351,56 September 2.512,30 October 3.415,01 November 3.406,43 December 2.565,54 Total 33.029,00 Table 5 Monthly consumption for the school. (Source: [Own]) Figure 9 shows the consumption for a typical winter and summer day, in order to observe the behavior of the consumption curve for a day in which the school is opened and a day in which the school is closed. As it is clearly seen, during a typical summer day when the school is closed, the consumption is almost 0, whereas in a winter day when the school is opened, the consumption during operating hours much higher. It must be taken into account that this winter day corresponds to a day from Monday to Friday, not the weekends where the school is obviously closed. Figure 8 Monthly consumption for the school. (Source: [Own]) 0,00 500,00 1000,00 1500,00 2000,00 2500,00 3000,00 3500,00 4000,00 Consumption (kWh) School consumption Page 38 Report 4.3.2. Football field After checking the football field’s town’s bill, an annual consumption of 37.780 kWh has been selected. The below consumption profile has been obtained after entering the data to the simulation tool. As can be observed in Figure 10, consumption in summer is lower than in winter months, where there are more football competitions and trainings. Month Consumption (kWh) January 3.812,07 February 3.282,31 March 3.122,75 April 2.663,65 May 2.653,01 June 2.684,60 July 2.229,82 August 2.300,53 September 3.773,75 October 3.760,62 November 3.977,37 December 3.519,50 Total 37.780,00 Table 6 Monthly consumption for the football field. (Source: [Own]) Figure 9 Charge curve for the school. (Source: [Own]) 0 2 4 6 8 10 12 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Consumption (kWh) Hours Consumption for a typical day at the school Typical winter day Typical summer day Creation of an energy community Page 39 Figure 10 Monthly consumption for the school. (Source: [Own]) Looking at the charge curve, Figure 11, for a typical winter and summer day, it is clearly seen that most of the consumption happens during evening hours, approximately between 6 pm and 22 pm. That can be explained by understanding training hours, that happen when children go out of school and participate in extracurricular activities, such as football training. Also, it is observed that consumption in summer is way below consumption in winter, coinciding with months where there is no school and therefore no trainings. 4.3.3. Pavilion For the pavilion, the same procedure as for the school and football field was followed. Checking the energy bills provided by the Town Council, an annual consumption of 20.039 kWh was obtained. This value was entered into the consumption simulation tool and the following profile has been obtained: 0,00 500,00 1000,00 1500,00 2000,00 2500,00 3000,00 3500,00 4000,00 4500,00 Consumption (kWh) Football field annual consumption 0 2 4 6 8 10 12 14 16 18 20 12345678910 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Consumption (kWh) Hours Consumption for a typical day at the football field Typical winter day Typical summer day Figure 11 Charge curve for the school. (Source: [Own]) Page 40 Report Month Consumption (kWh) January 1.679,16 February 1.612,42 March 1.671,27 April 1.584,61 May 1.781,20 June 1.961,18 July 1.689,16 August 765,57 September 1.753,16 October 2.008,43 November 1.794,67 December 1.738,17 Total 20.039,00 Table 7 Monthly consumption for the pavilion. (Source: [Own]) In the charge curve, the behavior of the pavilion on both a typical summer and winter day can be observed. Upon analysis, it is evident that during the summer, it is likely closed, as there is minimal consumption. This could be attributed to schools being closed, thus students not attending the pavilion for physical education classes. Conversely, during the winter, numerous extracurricular competitions, such as basketball or figure skating may occur in the pavilion, which do not take place in the summer. Looking at Figure 13, regarding a typical winter day, there is a noticeable peak in 0,00 500,00 1000,00 1500,00 2000,00 2500,00 3000,00 3500,00 4000,00 Consumption (kWh) Pavilion annual consumption Figure 12 Charge curve for the pavilion. (Source: [Own]) Creation of an energy community Page 41 consumption during the evening hours, beginning around 5 pm. This can be attributed to sports training sessions. After students finish school, they often participate in extracurricular activities, many of which occur in the pavilion. 4.3.4. Summer pool The last selected public installation has been a summer pool. Same as in previous cases, by checking the annual bill for the town’s summer pool, an annual consumption of 21.154 kWh has been obtained. Observing both Table 8 and Figure 14, it is clear that summer months have the highest consumption, which is expected since it is a summer pool with its main activity occurring during summer. The consumption during winter can be explained by maintenance duties. Month Consumption (kWh) January 1.332,15 February 825,91 March 1.052,60 April 1.230,05 May 1.468,28 June 2.235,25 July 3.560,71 August 3.794,08 September 1.570,99 October 1.319,39 November 1.351,60 December 1.412,98 0 1 2 3 4 5 6 12345678910 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Consumption (kWh) Hours Consumption for a typical day at the pavilion Typical winter day Typical summer day Figure 13 Charge curve for the pavilion. (Source: [Own]) Page 48 Report subscribed to a Tariff 2.0TD, meaning they have contracted a power lower than 15 kW. With all the consumptions of all the users participating in the energy community, all the tariffs in which each one of them is subscribed and the tariff prices, the annual energy bill for each one of them has been computed. School Football field Pavilion Summer pool House + EV House Apartment Annual energy cost (€/year) 11.308,5 13.930,7 7.066,3 7.330,1 3.661,2 3.275,2 1.875,4 Table 13 Annual energy cost for each consumer. (Source: [Own]) Surpluses compensation The simplified mechanism surpluses compensation consists on a payment of the distribution company of the surplus hourly energy of each consumer in the billing period. In order to benefit from this compensation, the user must be subscribed in the selfconsumption modality with surpluses compensation. The System Operator (SO) communicates to the distribution company the hourly surpluses generated, and the distribution company obtains the average price on the electric market for all the surpluses that are assigned and compensates the consumer with this surplus energy. The maximum import that can be compensated is the one bought from the network, meaning that in any case the compensation can be neither negative nor compensating the rest of the taxes. In the case of ENDESA [22], compensates these surpluses at a price of 0,06€/kWh. Contracted electrical power Last but not least, it is important to also consider the contracted power. The contracted power, as stablished by ENDESA, is the number of kilowatts (kW) that can be simultaneously demanded from your home’s electrical grid [23]. For instance, if two powerful appliances are turned on at the same time, let’s say a 2,2-kW oven and a 2-kW air conditioner, a contracted power of 4,2 kW will be asked. However, if the contracted power is 4 kW, the fuses will blow and you will run out of electricity. However, it is important to keep in mind that the solution is not to contract a very high power, since the higher the contracted power, the higher the monthly bill will be. After all, the consumption is something that can be adjusted when coming to control the expense, but the power is a fixed expense. Creation of an energy community Page 49 In the case of this project, and after analyzing the electrical bills for each public installation, the following contracted powers have been selected: school (30,5 kW), football field (55 kW), pavilion (6,3 kW) and summer pool (5,5 kW). For the houses and apartments, the same contracted power has been selected for all of them. To determine this value, I have looked at my own’s house electrical bill, as the consumptions do not vary that much with the one’s selected for this project. Therefore, a contracted power of 5,5 kW has been chosen. Finally, Tables 14 and 15 show the base price for the power term, for both Tariff 2.0TD and Tariff 3.0TD. All the values correspond to ENDESA prices on May 2024 . It is important to notice that for the contracted power in Tariff 2.0TD, it is extremely common to only differentiate between two periods, peak (P1) and flat (P2). Period P1 is applied during the working days from 8 am to 12 pm and period P2 is applied on working days from 0 am to 8 am, weekends and holidays [24][25]. Period Price (€/kW and day) Peak (P1) 0,096963 Flat (P2) 0,030051 Table 14 Tariff 2.0TD contracted power. (Source: [24]) Period P1 P2 P3 P4 P5 P6 Price (€/kW and day) 0,04414 0,02725 0,01386 0,01245 0,00736 0,00535 Table 15 Tariff 3.0TD contracted power. (Source: [25]) 4.5. Calculations For calculating the electrical bill and therefore be able to compute both the energy and economic savings, it is essential to understand the different types of fees: • Power term: Is the fixed part of the electrical bill that has to be paid regardless of whether there is consumption. It includes tolls and the power contracted by the user in kilowatts, at the price agreed between the supplier and the consumer. • Energy term: Is the variable part of the bill that varies as a function of the monthly consumption. It includes the tolls and kilowatts hour that have been consumed at an agreed price between the supplier and the consumer. This is the only part of the bill that can be compensated depending on the monthly energy injected, measured hourly. • Special tax on electricity: Tax applied by the Ministry about the contracted power and the monthly consumption. Currently 0,5% on the total price of the remaining taxes. • Other services: An example would be the rental of measurement equipment’s, such as Page 50 Report the counter or the maintenance system. • Value added tax (VAT): Currently 21% on the total price of the remaining taxes. The computations have been carried out in Excel, by iterating each hour of the year. Once the consumption, the distribution coefficient and the PV generation assigned to that installation are known, the following formulas are applied: For the self-consumption, both PV production and the installation consumption must be compared: 𝑆𝑒𝑙𝑓− 𝑐𝑜𝑛𝑠𝑢𝑚𝑝𝑡𝑖𝑜𝑛 (𝑘𝑊ℎ)={𝑃𝑉 𝑝𝑟𝑜𝑑𝑢𝑐𝑡𝑖𝑜𝑛, 𝑃𝑉 𝑝𝑟𝑜𝑑𝑢𝑐𝑡𝑖𝑜𝑛>𝐶𝑜𝑛𝑠𝑢𝑚𝑝𝑡𝑖𝑜𝑛 𝐶𝑜𝑛𝑠𝑢𝑚𝑝𝑡𝑖𝑜𝑛, 𝑂𝑡ℎ𝑒𝑟𝑤𝑖𝑠𝑒 (1) For the surpluses, PV production and consumption have also been compared, in the following way: 𝑆𝑢𝑟𝑝𝑙𝑢𝑠𝑒𝑠 (𝑘𝑊ℎ) ={𝑃𝑉 𝑝𝑟𝑜𝑑𝑢𝑐𝑡𝑖𝑜𝑛− 𝐶𝑜𝑛𝑠𝑢𝑚𝑝𝑡𝑖𝑜𝑛, 𝑃𝑉 𝑝𝑟𝑜𝑑𝑢𝑐𝑡𝑖𝑜𝑛− 𝐶𝑜𝑛𝑠𝑢𝑚𝑝𝑡𝑖𝑜𝑛>0 0, 𝑂𝑡ℎ𝑒𝑟𝑤𝑖𝑠𝑒 (2) In the case of the network consumption when having a PV installation, the following condition is applied: 𝑁𝑒𝑡𝑤𝑜𝑟𝑘 𝑐𝑜𝑛𝑠𝑢𝑚𝑝𝑡𝑖𝑜𝑛 𝑤𝑖𝑡ℎ 𝑃𝑉 𝑖𝑛𝑠𝑡𝑎𝑙𝑙𝑎𝑡𝑖𝑜𝑛 (𝑘𝑊ℎ) ={𝐶𝑜𝑛𝑠𝑢𝑚𝑝𝑡𝑖𝑜𝑛−𝑠𝑒𝑙𝑓 𝑐𝑜𝑛𝑠𝑢𝑚𝑝𝑡𝑖𝑜𝑛, 𝑆𝑒𝑙𝑓 𝑜𝑛𝑠𝑢𝑚𝑝𝑡𝑖𝑜𝑛<𝐶𝑜𝑛𝑠𝑢𝑚𝑝𝑡𝑖𝑜𝑛 0, 𝑂𝑡ℎ𝑒𝑟𝑤𝑖𝑠𝑒 (3) For the energy price, as there is a different price for each period (P1… P6), an iteration has also been carried out, by applying each price to each corresponding period depending on the hour of the day. Let’s see this equation with an example for Tariff 2.0TD (3 periods). For a Tariff 3.0TD, the same equation will be applied but including 6 periods: 𝐸𝑛𝑒𝑟𝑔𝑦 𝑝𝑟𝑖𝑐𝑒 (€)={𝑃𝑟𝑖𝑐𝑒(𝑃1), 𝑃𝑒𝑟𝑖𝑜𝑑=𝑃1 𝑃𝑟𝑖𝑐𝑒(𝑃2), 𝑃𝑒𝑟𝑖𝑜𝑑=𝑃2 𝑃𝑟𝑖𝑐𝑒(𝑃3), 𝑃𝑒𝑟𝑖𝑜𝑑=𝑃3 (4) For the following computations is important to take into account the following economic values that have been used for calculating the energy bill: VAT 21% Electricity tax 0,5% Surplus price 0,06 €/kWh Table 16 Economic data for electrical bill calculation. (Source: [26]) Creation of an energy community Page 51 Energy costs with and without PV installation are computed in the same way, just varying the consumption: for the case without PV production, the consumption will be the overall installation consumption, while for the case with PV production, the consumption will be just the one coming from the network, once subtracted the PV one. 𝐸𝑛𝑒𝑟𝑔𝑦 𝑐𝑜𝑠𝑡 (€)=𝐶𝑜𝑛𝑠𝑢𝑚𝑝𝑡𝑖𝑜𝑛∗ 𝐸𝑛𝑒𝑟𝑔𝑦 𝑝𝑟𝑖𝑐𝑒∗ (1+𝑉𝐴𝑇)∗ (1 + 𝐸𝑙𝑒𝑐𝑡𝑟𝑖𝑐𝑖𝑡𝑦 𝑡𝑎𝑥) (5) And for the surpluses cost, the same concept is applied: 𝑆𝑢𝑟𝑝𝑙𝑢𝑠𝑒𝑠 𝑐𝑜𝑠𝑡 (€)=𝑆𝑢𝑟𝑝𝑙𝑢𝑠𝑒𝑠∗ 𝑆𝑢𝑟𝑝𝑙𝑢𝑠𝑒𝑠 𝑝𝑟𝑖𝑐𝑒∗ (1+𝑉𝐴𝑇)∗(1 +𝐸𝑙𝑒𝑐𝑡𝑟𝑖𝑐𝑖𝑡𝑦 𝑡𝑎𝑥) (6) Finally, for the contracted power term, the computation has been as follows: 𝐶𝑜𝑛𝑡𝑟𝑎𝑐𝑡𝑒𝑑 𝑝𝑜𝑤𝑒𝑟 𝑐𝑜𝑠𝑡=𝐶𝑜𝑛𝑡𝑟𝑎𝑐𝑡𝑒𝑑 𝑝𝑜𝑤𝑒𝑟∗30∗12∗ 𝑃𝑜𝑤𝑒𝑟 𝑝𝑟𝑖𝑐𝑒 (𝑃𝑖) (7) Where the contracted power is constant, 30 corresponds to an average of 30 days per month, for 12 months, and for each period (𝑃𝑖), where i=1… 6. Page 52 Report 5. Results and discussion RD 244/2019 specifies that in order to participate in this kind of self-consumption with surplus compensation, the following points must be achieved: • Generation source must be renewable. • Installed power must not exceed 100 kW. • Exists a contract between the producer and consumer regarding the surpluses compensation mechanism. • The installation does not have a specific remuneration scheme granted, meaning it is not subject to the regime for remunerating electricity production activity from renewable sources. • The installation’s connection mode is carried out via an internal network. Therefore, for the following case studies, the PV generating installation will be the school, with a nominal power of 90 kWn (<100 kWn). Meanwhile, the consumers will be both public installations (school, pavilion, football field and summer pool) and private users (houses, houses + EV and apartments). The main reason why only one generating installation has been selected to implement the energy community is due to the ability to opt for the collective self-consumption scheme with surplus energy. The following sections show three different case studies, with the objective of comparing their results and conclude which energy distribution is the most optimal one. The first case study will consist of distributing the PV production only between the public town council equipment (school, football field, pavilion, and summer pool), simulating the current real-life case where does not exist an energy community and all the PV energy is consumed in a common self-consumption. For the second case study, both public and private installations will be considered. Houses and apartments will receive a 1 kWp package (established for this energy community) and the rest of the energy will be distributed between the other installations, in proportion to their consumption and statically along the year. Finally, the third case study will distribute the PV production in the same way as in case study two, but for the case of the public installations, the energy will be hourly distributed throughout the year, meaning that each hour of each day will have a different distribution coefficient. Creation of an energy community Page 53 5.1. Case study 1 For the first case study, only the four municipal buildings will be considered. The intention of this first study is to simulate the current situation in the town, where all the PV production is distributed solely among the town council installations. Additionally, they are currently using a static distribution method, allocating a proportion of PV energy to each piece of equipment based on each building's consumption. Table 17 shows all the data that will be used in this case study. PV production (kWh/year) School 145.136,29 Consumptions (kWh/year) School 33.029,00 Football field 37.780,00 Pavilion 20.039,00 Summer pool 21.154,00 TOTAL 112.002,00 Table 17 Annual values of production and consumptions. (Source: [Own]) In Figure 20 can be observed in which proportion each installation contributes to the overall consumption. This contribution will translate in the static distribution coefficients along a natural year. 29% 34% 18% 19% Consumption proportion with respect to the overall consumption School Football field Pavilion Summer pool Figure 20 Consumption distribution. (Source: [Own]) Page 54 Report Therefore, these results translate such that: ß1=0,2949, ß2=0,3373, ß3=0,1789 and ß4=0,1889. These are represented in the table below with each installation’s surpluses: Distribution coefficients Surpluses (kWh) Savings (€) School 0,2949 25.423,34 7.256,63 Football field 0,3373 36.177,38 6.578,57 Pavilion 0,1789 16.972,13 4.356,68 Summer pool 0,1889 17.458,60 4.729,91 Table 18 Results with static distribution and only public installations. (Source: [Own]) This configuration leads to a total surplus of 96.031,45 kWh and total savings of 22.921,79€. The previous coefficients are divided in the following way: Figure 21 Static distribution coefficients: PV distribution. (Source: [Own]) As explained at the beginning of the section and represented in Figure 21, each installation receives the proportion of PV energy equivalent to its contribution on the overall consumption. Therefore, those installations with greater consumption receives a greater amount of PV production. Since both the school and the pavilion have similar consumption profiles, they receive a resemblant amount of energy. The same happens with the pavilion and the summer pool. 29% 18% 34% 19% Distribution of the overall PV production School Pavilion Football field Summer pool Creation of an energy community Page 55 Observing Figure 22, it is seen that approximately, half of the consumption is covered by the grid and the other half is covered by the PV installation, meaning that the PV cannot cover all the demand. As represented in Figure 23 of the overall school PV production energy, only 34% is selfconsumed by all the installations, while the remaining energy, approximately 66% is fed into the grid as surpluses, which in the case of this energy community are compensated (since P<100kW). This is not an optimal distribution since most of the PV production energy is fed back into the grid instead of self-consumed. The following cases of study have the goal of improving these results to obtain a higher benefit (self-consuming more energy and reducing the surpluses). Figures 24-27 represent the economic benefits that this configuration would lead, by representing the energy cost with and without self-consumption. Also, the savings are represented, which are computed by adding both the self-consumption and the surpluses. 34% 66% Destination of PV production energy Self-consumption Surpluses 44% 56% Electricity consumption coverage Self-consumed energy Network energy Figure 23 Static distribution. Consumption coverage. (Source: [Own]) Figure 22 Static distribution. Production destination. (Source: [Own]) Page 56 Report 0 100 200 300 400 500 600 0 500 1000 1500 2000 2500 3000 Savings (€) Cost (€) Economic analysis Football Field Network energy cost without PV Network energy cost with PV Savings Figure 24 Static distribution. Economic analysis for the school. (Source: [Own]) Figure 25 Static distribution. Economic analysis for the football field. (Source: [Own]) 0 100 200 300 400 500 600 700 800 0 500 1000 1500 2000 2500 Savings (€) Cost (€) Economic analysis School Network energy cost without PV Network energy cost with PV Savings Creation of an energy community Page 57 Comparing the energy costs with and without PV installation, it is evident that there are savings due to the self-consumption of part of the energy. Also, observing the savings curves, it is apparent that the school, the pavilion, and the football field experience a decrease in their savings in the summer months, due to the low usage of these facilities compared to the rest of the year. Conversely, the swimming pool sees higher savings in the summer months since it has increased consumption during this period, leading to greater self-consumption. 0 50 100 150 200 250 300 350 400 450 0 200 400 600 800 1000 1200 1400 Savings (€) Cost (€) Economic analysis Pavilion Network energy cost without PV Network energy cost with PV Savings 0 100 200 300 400 500 600 700 0 200 400 600 800 1000 1200 1400 Savings (€) Cost (€) Economic analysis Summer Pool Network energy cost without PV Network energy cost with PV Savings Figure 27 Static distribution. Economic analysis for the Summer Pool. (Source: [Own]). Figure 26 Static distribution. Economic analysis for the pavilion. (Source: [Own]). Page 64 Report 0 50 100 150 200 250 300 350 0 200 400 600 800 1000 1200 1400 Savings (€) Cost (€) Economic analysis Pavilion Network energy cost without PV Network energy cost with PV Savings 0 50 100 150 200 250 300 350 400 450 500 0 200 400 600 800 1000 1200 1400 Savings (€) Cost (€) Economic analysis Summer Pool Network energy cost without PV Network energy cost with PV Savings Figure 33 Static distribution. Economic analysis for the pavilion. (Source: [Own]) Figure 34 Static distribution. Economic analysis for the summer pool. (Source: [Own]) Creation of an energy community Page 65 Comparing both the energy cost with and without PV installation, it is seen that there are savings due to the self-consumption of part of the energy. Also, observing the savings curves for public installations, the same happens as in case study 1, where those installations with greater consumption during summer months showed a higher savings in those months due to higher PV production. For the houses, we previously analyzed its consumption, which increases in summer, therefore their savings are also greater in these months, as they consume more but also receive higher PV production. Only houses + EV have been represented, as the three types have similar profiles and representing the three of them would not provide any relevant information. The following tables show a summary of each installation’s annual bill. Each table shows both the energy and economic comparison between taking part in the energy community or consuming all the energy from the grid. Highlighted in green, the final economic savings are shown. Annual bill for the school Parameters Without PV installation With PV installation Annual consumption (kWh) 21.154,00 PV production (kWh) - 10.966,50 Self-consumption (kWh) - 7.750,37 Surpluses (kWh) - 3.216,13 Grid consumption (kWh) 21.154,00 13.403,63 Energy cost + taxes (€) 7.019,11 4.302,16 0 10 20 30 40 50 60 70 0 100 200 300 400 500 600 700 Savings (€) Cost (€) Economic analysis of a single house + EV Network energy cost without PV Network energy cost with PV Savings Figure 27 Static distribution. Economic analysis a house + EV. (Source: [Own]) Page 66 Report Surpluses compensation (€) - -234,66 Power cost (€) 310,99 Total electricity bill (€) 11.308,52 7.383,77 Savings in the electricity bill (€) - 3.924,75 Table 25 Energy bill for the school. (Source: [Own]) Annual bill for the football field Parameters Without PV installation With PV installation Annual consumption (kWh) 37.780,00 PV production (kWh) - 19.581,79 Self-consumption (kWh) - 10.634,59 Surpluses (kWh) - 8.947,20 Grid consumption (kWh) 37.780,00 27.145,41 Energy cost + taxes (€) 11.744,60 8.453,36 Surpluses compensation (€) - -652,81 Power cost (€) 2.186,10 Total electricity bill (€) 13.930,70 9.986,65 Savings in the electricity bill (€) - 3.944,05 Table 26 Energy bill for the football field. (Source: [Own]) Annual bill for the pavilion Parameters Without PV installation With PV installation Annual consumption (kWh) 20.039,00 PV production (kWh) - 10.385,95 Self-consumption (kWh) - 7.249,95 Surpluses (kWh) - 3.136,52 Grid consumption (kWh) 20.039 12.789,57 Energy cost + taxes (€) 6.710,03 4.168,68 Surpluses compensation (€) - -228,85 Power cost (€) 356,22 Total electricity bill (€) 7.066,25 4.296,05 Savings in the electricity bill (€) - 2.770,20 Table 27 Energy bill for the pavilion. (Source: [Own]) Annual bill for the summer pool Parameters Without PV installation With PV installation Creation of an energy community Page 67 Annual consumption (kWh) 21.154,00 PV production (kWh) - 10.966,50 Self-consumption (kWh) - 7.750,37 Surpluses (kWh) - 3.216,13 Grid consumption (kWh) 21.154,00 13.403,63 Energy cost + taxes (€) 7.019,11 4.302,16 Surpluses compensation (€) - -234,66 Power cost (€) - Total electricity bill (€) 7330,10 4.378,49 Savings in the electricity bill (€) - 2.951,61 Table 28 Energy bill for the summer pool. (Source: [Own]) Annual bill for a single house + EV Parameters Without PV installation With PV installation Annual consumption (kWh) 10.500,00 Production 1 kWp (kWh) - 1.612,63 Self-consumption (kWh) - 1.323,84 Surpluses (kWh) - 288,78 Grid consumption (kWh) 10.500,00 9.176,16 Energy cost + taxes (€) 3.350,18 2.883,61 Surpluses compensation (€) - -21,07 Power cost (€) 310,99 Total electricity bill (€) 3.661,17 3.173,53 Fee for 1 kWp (€) - 50,00 Savings in the electricity bill (€) - 437,64 Table 29 Energy bill for a single house + EV. (Source: [Own]) Annual bill for a single house Parameters Without PV installation With PV installation Annual consumption (kWh) 9.000,00 Production 1 kWp (kWh) - 1.612,63 Self-consumption (kWh) - 1.345,33 Surpluses (kWh) - 267,29 Grid consumption (kWh) 9.000,00 7.645,67 Energy cost + taxes (€) 2.964,23 2.489,92 Surpluses compensation (€) - -19,50 Page 68 Report Power cost (€) 310,99 Total electricity bill (€) 3.275,22 2.781,41 Fee for 1 kWp (€) - 50,00 Savings in the electricity bill (€) - 443,81 Table 30 Energy bill for a single house. (Source: [Own]) Annual bill for a single apartment Parameters Without PV installation With PV installation Annual consumption (kWh) 4.750,00 Production 1 kWp (kWh) - 1.612,63 Self-consumption (kWh) - 1.024,59 Surpluses (kWh) - 588,03 Grid consumption (kWh) 4.750,00 3.725,41 Energy cost + taxes (€) 1.564,46 1.205,12 Surpluses compensation (€) - -42,09 Power cost (€) 310,99 Total electricity bill (€) 1.875,44 1.473,21 Fee for 1 kWp (€) - 50,00 Savings in the electricity bill (€) - 352,24 Table 31 Energy bill for a single apartment. (Source: [Own]) After looking at all the results, with this configuration, the Town Council would save a total amount of 13.772,02€ each year, representing a saving of 34,75%. For the private users after including the 50€/year fee for the transfer of 1kWp, they can save from 352,24€/year in the case of an apartment to 443,81€/year in the case of a house. annually. This represents a saving of around 15%. 5.3. Case study 3 Finally, for this last case study an hourly distribution will be carried out. The hypothesis before making this distribution is that it will be more optimal than the two previous ones, since the energy will be distributed such that those time periods with more consumption will receive a higher PV production, and vice versa, without establishing a fix amount to each installation. The idea behind this kind of distribution, is to optimize the energy distribution as a community, and not for each individual installation. So that both studies can be compared, the same criterion when distributing the energy Creation of an energy community Page 69 between public and private installations will be followed. Therefore, Town Council’s installation will continue to receive the 40% of the PV production, whereas the remaining 60% will go to private houses. At this point, it is crucial to remember how the energy community was formed, meaning that each private house or apartment receives fixed packages of 1 kWp, regardless of their consumption. However, in this last case study, this rule will be broken to examine how an hourly distribution affects the three different types of houses or apartments. The goal of this distribution is to determine if real-life energy communities could be improved by not fixing those 1 kWp packages, but instead implementing an optimized hourly distribution. Therefore, in this case, energy will not be distributed in relation to each installation’s consumption, but it will be distributed such that the overall energy community leads to the most optimal result, implying the reduction of surpluses. Therefore, new distribution coefficients will appear in this case. As happened in the previous cases, the data for this section is the following one: PV production (kWh/year) School 145.136,29 Consumptions (kWh/year) School 33.029,00 Football field 37.780,00 Pavilion 20.039,00 Summer pool 21.154,00 18 houses + EV 189.000,00 18 houses 162.000,00 18 apartments 85.500,00 TOTAL 548.502,00 Table 32 Annual values of production and consumption. (Source: [Own]) The 58.054,52 kWh corresponding to the 40% PV production are now distributed finding the most optimal result. After carrying out the optimization it has been obtained that the most optimal distribution for the public installations are as follows: school (28,78%), football field (30,82%), pavilion (19,39%) and summer pool (21,01%). Obviously, the installation with higher consumption receives the highest proportion of energy, but now this is not directly proportional with the overall consumption, but depending on each hour and each installation. For the private residences, the constraint of 1 kWp package has been eliminated while still maintaining the supply to 54 residences. Therefore, in this case, the distribution coefficients, surpluses and savings are as follows: Page 70 Report Distribution coefficients Surpluses (kWh) Savings (€) School 0,11512 4.590,42 5.069,58 Football field 0,12328 4.560,51 3.493,2 Pavilion 0,07756 3.132,02 2.793,24 Summer pool 0,08404 4.497,81 3.307,78 18 houses + EV 0,26022 7.345,80 9.726,48 18 houses 0,22242 7.709,4 10.207,8 18 apartments 0,11736 4.068,79 5.387,40 Table 33 Results with an hourly distribution. (Source: [Own]) These results translate such that: ß1=0,11512, ß2=0,12328, ß3=0,07756, ß4=0,08404, ß5=0,26022, ß6=0,22242 and ß5=0,11736. For each private residence, the distribution coefficient will be ß5,1…18 =0,014457, ß6,1…18 =0,012357 and ß7,1…18 =0,00652. For this first case scenario, the configuration leads to a total surplus of 35.904,75 kWh and total savings of 39.985,48€. Carrying out the same analysis than with the previous cases, the overall PV distribution with the previous coefficients is now: 14% 7% 10% 9% 23% 24% 13% Distribution of the overall PV production School Pavilion Football field Summer pool 18 houses + EV 18 houses 18 apartments Figure 28 Hourly distribution coefficients: PV distribution. (Source: [Own]) Creation of an energy community Page 71 Observing Figure 37 and 38 and comparing them with case study 1, it is seen that with this new configuration the surpluses are reduced while self-consumption is increased, indicating that the energy community has been optimized. Surpluses have been reduced from 29% (case study 1) to 25% (case study 2), and consequently self-consumption has increased by the same proportion. Regarding energy consumption coverage, the values are almost the same as in case study 1, but in this case, PV production covers 1% more than with static coefficients. Consequently, network energy has been reduced by 1%. Clearly, the energy community has been optimized but only by a small amount, and the installation does not have the capacity to cover all the demand as, previously explained. Same as before, Figures 40-43 represent the economic benefits that this configuration would lead, by representing the energy cost with and without self-consumption. Also, the savings are represented, which are computed by adding both the self-consumption and the surpluses. Figure 29 Hourly distribution. Consumption coverage. (Source: [Own]) 75% 25% Destination of PV production energy Self-consumption Surpluses Figure 30 Hourly distribution. Production destination. (Source: [Own]) 20% 80% Electricity consumption coverage Self-consumed energy Network energy Page 72 Report 0 100 200 300 400 500 600 700 0 500 1000 1500 2000 2500 Savings (€) Cost (€) Economic analysis School Network energy cost without PV Network energy cost with PV Savings Figure 39 Hourly distribution. Economic analysis the school. (Source: [Own]) 0 50 100 150 200 250 300 350 400 450 0 500 1000 1500 2000 2500 3000 Savings (€) Cost (€) Economic analysis Football Field Network energy cost without PV Network energy cost with PV Savings Figure 40 Hourly distribution. Economic analysis of the football field. (Source: [Own]) Creation of an energy community Page 73 0 50 100 150 200 250 300 350 0 200 400 600 800 1000 1200 1400 Savings (€) Cost (€) Economic analysis Pavilion Network energy cost without PV Network energy cost with PV Savings 0 100 200 300 400 500 600 700 0 200 400 600 800 1000 1200 1400 Savings (€) Cost (€) Economic analysis Summer Pool Network energy cost without PV Network energy cost with PV Savings Figure 41 Hourly distribution. Economic analysis the pavilion. (Source: [Own]) Figure 42 Hourly distribution. Economic analysis of the summer pool. (Source: [Own]) Page 80 Report Installation Distribution coefficients (ßi) Case study 1 Case study 2 Case study 3 School 0,2949 0,1180 0,1151 Football field 0,3373 0,1349 0,1233 Pavilion 0,1789 0,0716 0,0776 Summer pool 0,1889 0,0756 0,0840 18 houses + EV - 0,2000 0,2602 18 houses - 0,2000 0,2224 18 apartments - 0,2000 0,1174 TOTAL 1,00 1,00 1,00 Table 43 Distribution coefficients comparison. (Source: [Own]) The most remarkable part of distribution coefficients is observed on the private residences between case study 2 and case study 3, which goes to a fix amount of 0,2 for each residence, to varying depending on the consumption. It is important to note that the coefficients of case studies 1 and 2 are representative for all the hours of the year, because when a static distribution is performed, each hour obtains the same distribution, regardless of consumption. In case study 3, these coefficients shown in the table represent an average of all the coefficients of the year, but each hour has a different coefficient that does not coincide exactly with the one shown above. Installation Self-consumed energy (kWh) Case study 1 Case study 2 Case study 3 School 17.377,36 11.322,53 15.183,48 Football field 12.777,09 10.634,59 10.227,60 Pavilion 8.992,75 7.249,43 7.330,71 Summer pool 9.957,64 7.750,37 8.531,97 18 houses + EV - 23.829,12 26.103,78 18 houses - 24.215,94 27.395,46 18 apartments - 18.442,62 14.458,68 TOTAL 49.104,84 103.444,60 109.231,68 Table 44 Self-consumed energy comparison. (Source: [Own]) In parallel with what happened with surpluses, self-consumed energy represents the complementary part, as all the PV production is either self-consumed or injected to the grid as surpluses. Therefore, when surpluses decreased by approximately 50% between case study 1 and 2, self-consumption has clearly increased by the same proportion. Even though public installations have decreased the self-consumption, it is clearly seen that the implication of private houses is beneficial to the community, as it helps decreasing Creation of an energy community Page 81 surpluses and increasing self-consumption. Between case study 2 and case study 3, only an increase in self-consumption of approximately 5.000 kWh is obtained, but the hypothesis that including hourly coefficients would optimize the community has been fulfilled. Installation Network energy Case study 1 Case study 2 Case study 3 School 15.651,64 21.706,47 17.854,52 Football field 25.002,91 27.145,41 27.552,40 Pavilion 11.046,25 12.789,57 12.708,29 Summer pool 11.196,36 13.403,63 12.622,03 18 houses + EV - 165.170,88 162.896,22 18 houses - 137.784,06 134.604,54 18 apartments - 67.057,38 71.041,32 TOTAL 62.897,16 445.057,40 439.279,32 Table 45 Network energy comparison. (Source: [Own]) Finally, regarding network energy consumption, it is also the complementary part of the energy that is self-consumed. From case study 1 to case study 2, the huge increase in network energy is clearly for the addition of 54 residences, that were not considered in case study 1. Looking at public installations between these two cases, it is seen that network energy has also increased, which is theoretically bad. However, it must be taken into account that in case study 1, the 100% of PV production was given to public installations, whereas in case study 2 only 40% of this production goes to these installations. Comparing case study 2 and 3, network energy decreases from 445.057,40 kWh to 439.279,32 kWh, which is a good sign. Concluding the results comparison, what has been seen is that when going from shared self-consumption to an actual energy community, by including both public installations and private residences, surpluses have been minimized by more than 50%, which minimizing surpluses was the main goal of creating an energy community. Consequently, with the minimization of surpluses, less network energy is used which translates into economic benefits. Therefore, it is clearly seen that the constitution of an energy community is a great form of optimizing PV production. Comparing case study 2 with case study 3, it has been possible to optimize the energy community slightly more, but not by a significant amount. Therefore, carrying out an hourly distribution is obviously more effective, but it does not translate in a substantial economic benefit, only by approximately 1.400€. Page 82 Report From the perspective of the houses/apartments, this represents significant savings while contributing to a world powered by green energy sources. They achieve substantial economic benefits without needing to install PV panels on their houses, which may be impossible for some of them. Lastly, from the Town Council’s point of view, transitioning from shared self-consumption to forming an energy community still yields economic benefits, albeit reduced ones. They now consume less PV energy themselves and allocate that proportion to their residents. However, it is important to consider that energy communities promoted by Town Council have a primary objective of fostering community spirit among residents and maximizing the supply of PV energy. Additionally, as will be discussed in the economic assessment section, despite generating lower immediate economic benefits, over the typical lifespan of the PV installation, they will accumulate significant economic gains. Page 83 Report 7. Planning CREATION OF AN ENERGY COMMUNITY Project initiation: 1st of February 2024 Author: Laia Saborit Codinachs TASK PROGRESS Week 1 Week 2 Week 3 Week 4 Week 1 Week 2 Week 3 Week 4 Week 1 Week 2 Week 3 Week 4 Week 1 Week 2 Week 3 Week 4 Week 1 Week 2 Week 3 Week 4 Theoretical background 100% 100% 100% 100% Methodology and equipment 100% 100% 100% 100% Results and discussion 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% Optimal deadline for each of the task Extra time for each of the task Period for delivering the deliverables Final deliverable of the project Project's impact and conclusions Social and gender equality assessment Environmental assessment Economic assessment Conclusions Case study 2: Static distribution among public and private installations Case study 3: Hourly distribution among public and private installations Comparison between each case study Deliverable of final results with proper discussion Deliverable of the state of the art Selection and analysis of the PV production installation Selection and analysis of the consumers profile Deliverable of generation and consumption curves Research of the energy cost and bill's characteristics Case study 1: Static distribution among public equipments Research of current context of photovoltaic energy Research of energy communities in our country Research of legal, economic and environmental context of energy communities june-24 feb-24 march-24 april-24 may-24 CREATION OF AN ENERGY COMMUNITY Project initiation: 1st of February 2024 Author: Laia Saborit Codinachs TASK PROGRESS Week 1 Week 2 Week 3 Week 4 Week 1 Week 2 Week 3 Week 4 Week 1 Week 2 Week 3 Week 4 Week 1 Week 2 Week 3 Week 4 Week 1 Week 2 Week 3 Week 4 Theoretical background 100% 100% 100% 100% Methodology and equipment 100% 100% 100% 100% Results and discussion 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% Optimal deadline for each of the task Extra time for each of the task Period for delivering the deliverables Final deliverable of the project Project's impact and conclusions Social and gender equality assessment Environmental assessment Economic assessment Conclusions Case study 2: Static distribution among public and private installations Case study 3: Hourly distribution among public and private installations Comparison between each case study Deliverable of final results with proper discussion Deliverable of the state of the art Selection and analysis of the PV production installation Selection and analysis of the consumers profile Deliverable of generation and consumption curves Research of the energy cost and bill's characteristics Case study 1: Static distribution among public equipments Research of current context of photovoltaic energy Research of energy communities in our country Research of legal, economic and environmental context of energy communities june-24 feb-24 march-24 april-24 may-24 Page 84 Report 8. Economic assessment 8.1. Project economic assessment This section will evaluate the project for a useful life of 25 years, as it is the typical useful life for a photovoltaic installation, by means of a profit and loss statement (P&L). It is important to highlight that the P&L has been carried out from the point of view of the Town Council, meaning that profits and losses are for them. Real economic data for the PV installation of the school has been taken, obtained from the Town Council itself. Regarding maintenance costs, average values have been considered. Also, an installation of 90 kWn has been considered, as it is the one working with. To determine the total losses, the actual initial investment values have been considered. Maintenance expenses for the installation, platform and other costs were computed over a 25-year period. Furthermore, the establishment of the energy community was also taken into account. The profit calculation has been conducted by aggregating self-consumption, surplus compensation and participation fees. For self-consumption, the average value of selfconsumed energy from cases 2 and 3 has been used, as these are the cases that actually consider the constitution of an energy community. It has been observed that 73% of the total PV production is self-consumed within the community, while 27% consists of surpluses that can be compensated. Finally, a participation fee of 50€/kWp has been taken. Even though the last case study contemplated a different scenario, where this participation fee varied depending on consumption, to make this computation easier the fix value has been taken. Therefore, Tables 46 and 47 summarize the P&L: Losses Initial investment 121.892,95 € Installation 92.360,65 € Civil works 15.370,80 € Project and procedures 3.000,00 € Safety and health 11.161,50 € Legalization 3.500,00 € *Possibility to apply for grants Technical maintenance of the installation 11.250,00 € 450€ x 25 years Platform, contract management… 50.000,00 € 2.000€ x 25 years Creation of an energy community Page 85 Establishment of the energy community (legal framework) 1.250,00 € TOTAL 184.392,95 € Table 46 Losses. Profit and loss statement. (Source: [Own]) Profits Energy study Town Council Self-consumption (73%) 704.490,18 € 0,265€ x kWh x 25 years Compensated surpluses (27%) 58.197,23 € 0,06€ x kWh x 25 years Participation fee 67.500,00 € 54 kWp x 50€/kWp x 25 years TOTAL 830.187,40 € Table 47 Profits. Profits and loss statement. (Source: [Own]) Finally, as can be observed comparing both the losses and profits, it is clearly seen that in 25 years, return on investment (ROI) is fully achieved and benefits are generated. Therefore, in 25 years, the energy community generates 645.794,45€ of benefits. 8.2. Engineer economic assessment Regarding the engineer economic assessment for this project the following will be considered. As it is stablished at the Industrial Technologies and Economic Analysis Bachelor’s Degree, this project translates into 12 ECTS [27]. One ECTS equals approximately 30 hours of work for the student, meaning that the total amount of time dedicated to this project is approximately 360 hours, which is the same as 15 days. As the project is carried out by the student and considering an approximate salary for a junior engineer as could be 15€/h, the total salary would be 5.400€. Breaking down the hours dedicated to each task and its equivalent salary, the following is obtained: Task Hours dedicated to each task Salary for the task Theoretical background 100h 1.500€ Methodology and equipment 80h 1.200€ Results and discussion 130h 1.950€ Project impact and conclusion 50h 750€ TOTAL 360h 5.400 Table 48 Description of project’s task costs. (Source: [Own]) Page 86 Report This project has not led to any experimental expenses, as every documentation has been done using the university license or own resources. Other expenses that must be taken into account are the computer amortization and electricity, for instance. For computing the computer’s amortization, the original price of the computer has been used, which is 1.200€, and a useful life of 5 years has been considered. As the project lasts for 5 months (from February to June), this time has been considered. Therefore, computer’s amortization has been computed in the following way: 𝐴𝑚𝑜𝑟𝑡𝑖𝑧𝑎𝑡𝑖𝑜𝑛 𝑐𝑜𝑠𝑡=𝑃𝑟𝑖𝑐𝑒− 𝑅𝑒𝑠𝑖𝑑𝑢𝑎𝑙 𝑝𝑟𝑖𝑐𝑒 𝑈𝑠𝑒𝑓𝑢𝑙 𝑙𝑖𝑓𝑒 · 𝑇𝑖𝑚𝑒 𝑒𝑚𝑝𝑙𝑜𝑦𝑒𝑑 =1.200€−0€ 5 𝑦𝑒𝑎𝑟𝑠 · 5 𝑚𝑜𝑛𝑡ℎ𝑠=100€ (8) For the electricity, the same hours as for the project must be considered, as all the tasks require the use of computer, which must be charged. Therefore, as stated before, the equivalent for 12 ECTS are 360 hours. It has been considered that a laptop consumes 0,2 kW [28] each hour and that it is used the total amount of time that is dedicated to this project, 360 hours. An average price of 0,265€/kWh has been taken, computed as the average of the three periods for 2.0TD Tariff, explained in previous sections. Therefore, the electricity price for the use of the computer has been: 𝐶𝑜𝑚𝑝𝑢𝑡𝑒𝑟 𝑒𝑙𝑒𝑐𝑡𝑟𝑖𝑐𝑖𝑡𝑦=0,2𝑘𝑊·360ℎ·0,265€ 𝑘𝑊ℎ=19,08€ (9) Also, an extra fixed amount of 15€ will be added to this expense as it is the price for having internet connection at home. A monthly bill is approximately 30€ and since the 360 hours employed to the project translates into 15 days, half a month, then half the internet bill price is taken. Finally, below it can be observed a summary of all the previous imports. To prevent unforeseen problems, 5% unexpected costs have been considered. Project development 5.400,00€ Computer amortization 100,00€ Energy consumption 34,08€ Total expected costs 5.534,08€ Unexpected costs (5%) 276,70€ TOTAL 5.810,78 Table 49 Cost summary. (Source: [Own]) Therefore, the total cost of the project equals 5.810,78€ without considering taxes. Taking into account the 21% VAT tax, the total cost increases up to 7.031,05€. Creation of an energy community Page 87 9. Environmental impact One of the main goals of this project was the minimization of surpluses as a community, by implementing the most optimal distribution coefficients. Surpluses reduction implies a reduction of the network energy consumption which translates in the reduction of the use of non-renewable energy. Consequently, green energy coming from PV installations consumption is increased. Moreover, this energy distribution can also be implemented in both big residential regions and industrial sectors, where climate emergency is clearly visible due to the bad management of resources. According to a report published by the UNEF in 2020 [29], solar PV installations avoided the emission of 6,3 million tons of CO2e in Spain in 2019, which equals to the annual emissions of 3 million cars. Also, solar PV energy provided the 4,6% of the overall Spain electricity in 2019. In order to compute the CO2e quantity that is saved with the use of PV energy in Spain, the following aspects must be taken into account: quantity of generated energy by the PV installations and quantity of generated energy by fossil fuels. Experts use complex mathematical models to carry out these computations, taking into account national production energy and greenhouse gas emissions associated with the production of energy from fossil fuels. For these computations, experts also take into account the CO2e emission factor associated with the energy production by means of fossil fuels. According to the Spanish electricity system report 2021 published by Red Eléctrica [30], the average emission factor of the national electricity system in 2021 was 0.201 kg CO2e/kWh. This means that, on average, 0,201 kg of CO2e are emitted for every kWh of energy produced from fossil fuels. Also, it is important to take into account that the quantity of CO2e that is avoided with the PV installations can vary depending on various factors, such as the PV installation dimensions, the location or the quantity of energy that is produced by fossil fuels in each region. After being more familiar with how this relation works, in the case of this project the savings in CO2e will be computed by multiplying the annual production energy (kWh) by the emission factor (CO2e /kWh), giving the avoided CO2e in the energy community: 𝐴𝑣𝑜𝑖𝑑𝑒𝑑 𝐶𝑂2𝑒=145.136,29 𝑘𝑊ℎ·0,201 𝑘𝑔𝐶𝑂2𝑒 𝑘𝑊ℎ=29.172,39 𝑘𝑔 𝐶𝑂2𝑒 (10) This means that this PV installation avoids the emission of more than 29 tons of CO2 each year, which is the same as planting 1.450 trees or travel 290.000 km by car. Page 88 Report 10. Social and gender equality assessment The object of study of this project is not conditioned by discriminatory differentiations of gender or social status, since it deals exclusively with the study of the creation of an energy community and the optimal form of distributing energy. However, taking a wider view in the engineering sector, gender differentiations are still a reality, despite the efforts of the institutions. A study from year 2011 about the distribution of academic positions by gender carried out by the UPC [31], still reflects the low representation of women in administration positions of the UPC. The study shows that in the academic course 2010-2011, there was a total number of 2.780 teaching and research staff, of which 647 (23,27%) were women and 2.133 (76,73%) were men. The following graph shows a comparison between women teaching and research staff for both 2006-2007 and 2010-2011 academic courses. It is observed that there is a positive trend in the number of women working at the UPC, suggesting that this number has likely continued to increase, approaching greater equality with the number of men. Figure 32 Teaching and research staff (Women). (Source: [31]) Analyzing now the number of newly admitted students also in course 2010-2011, it is observed that a total number of 5.114 students were admitted, of which 1.289 (25,21%) were women and 5.114 (74,79%) were men. As happened with the UPC personnel, there was a huge gender difference in students starting an engineering degree. If this number is compared with academic course 2006-2007, just an increase of approximately 1% on the number of women is observed. Therefore, although these data correspond to a relatively old time period, they illustrate the significant progress still needed to achieve the highly desirable gender equality among both students and teachers. Personally, it is believed that strides have been made over the past 10 years, but there is still more work to be done. Creation of an energy community Page 89 11. Conclusions This project began with the objective of creating an energy community constituted by a town council and evaluate the optimal method for distributing energy among its users. To identify the most efficient way of sharing energy within the LEC, three different models were developed and compared. These models simulate a LEC with hourly resolution for a full year, enabling the assessment of economic impacts such as variations in network prices, demand curves throughout the year, grid price fluctuations, and the management of surplus energy within the LEC. Real-life data from a photovoltaic generation installation was used, while consumption data was simulated using a software. The current PV regulation regarding shared self-consumption differentiates between fixed and variable distribution coefficients. Results from the energy analysis have led to several conclusions. It has been observed that distributing the energy generated by means of static coefficients does not allow to adjust the distribution of this energy to the demand of different consumers, as they can only acquire a single invariable value. On the contrary, with the introduction of hourly distribution coefficients, this limitation disappears since the energy distribution adapts to each consumer’s needs for each hour of each day throughout the year. In the analyzed case study, results have been better than those obtained with static coefficients. However, it should be noted that the difference was not very significant, considering the high number of variables and limitations present in the case study. It is likely that using these coefficients will be more effective when complementary real-life consumption profiles are used, as this would lead to more accurate results. Case study 1 involved representing the currently real-life scenario, where all the PV production from the generating installation is statically distributed only among public facilities, excluding private houses and apartments. The results are favorable in economic terms but generate a significant amount of surplus energy. Case study 2 included private installation profiles, thereby creating a local energy community. In this case, energy was also distributed statically. The results showed a decrease in surplus energy while continuing to provide economic benefits for both the town council and private houses and apartments. Finally, case study 3 implemented hourly distribution coefficients for both public and private installations. The results showed a decrease in surplus energy and an increase in economic savings, but not by a significant amount. Additionally, network dependence is lower than in the other two cases. Even though the results have been gratifying, demonstrating that implementing an energy community leads to optimal outcomes, many surpluses are still generated. To effectively