Full text
UPCommons Portal del coneixement obert de la UPC http://upcommons.upc.edu/e-prints Aquesta és una còpia de la versió author’s final draft d'un article publicat a la revista Solar Energy . URL d'aquest document a UPCommons E-prints: http://hdl.handle.net/2117/168360 Article publicat / Published paper : Arias, Fr. J., De Las Heras, S. (2019) A first estimate for thermal osmotic long storage. Solar Energy, vol. 190, p. 511-514. Doi: 10.1016/j.solener.2019.08.027
a1 3 4 5 6 7 8 9 10 11 12 13 14 15 A First Estimate for Thermal Osmotic Long Storage Francisco J. Ariasa∗ and Salvador De Las Herasa Department of Fluid Mechanics, University of Catalonia, ESEIAAT C/ Colom 11, 08222 Barcelona, Spain In this brief note, a first assessment on the possibilities for thermal osmotic storage using the thermal precipitation of aqueous solutions as alternative to sensible heat storage is performed. In a recent study it was found that the thermal dependence of the solubility of many common aqueous solutions could be harnessed to transform thermal energy into osmotic energy and then to run a heat powered cycle. Here, a scoping study is performed on the possibility to use such a property to storage thermal energy. Utilizing a transient model it was found that despite the fact that traditional sensible heat can stores much more thermal energy than osmotic does, however, for large Biot and Fourier numbers -which means compactness and long thermal storage, the osmotic storage becomes an attractive option. Additional R&D is required in order to arrive at a reliable practical and commercial design. 16 17 Keywords. Sensible heat storage, Osmotic energy.18 1. Introduction19 20 The object of this note was a first scoping study21 to compare and asses the attractiveness of thermal22 osmotic storage -by using the thermal precipitation of23 solute from aqueous solutions and the generation of two24 separated streams with two different salinities which can25 be stored indefinitely and releasing the osmotic energy26 only upon deliberated mixing, with traditional sensible27 heat storage. In a recent work, [1], it was discussed28 that because the thermal dependence of the solubility of29 aqueous solutions, it is possible to harness this feature30 to convert thermal energy into osmotic energy by using31 a proper process. However, in that early work, the32 thermal osmotic energy by using aqueous solution was33 intended to run powered heat cycles (osmotic heat34 engines), but the idea could be equally interesting for35 thermal storage in comparison with sensible heat. Fig.136 is a sketch of the thermal osmotic storage concept by37 thermal precipitation of aqueous solutions which will be38 discussed.39 40 •Thermal osmotic heat storage vs Sensible41 heat storage42 43 In terms of amount, sensible heat can potentially44 store larger amount of energy than osmotic does. For45 example, if one considers the case for water, with a46 specific heat capacity cp≈1.16 kWh/(m3K), then a47 temperature difference ∆T= 80K , will translate into48 92 kWh/(m3), however, osmotic energy even assuming49 large salinity gradients can store around 5 kWh/(m3)50 (per volume of solution) or thereabouts, [4]. However,51 the only advantage of osmotic energy is that it can be52 ∗Corresponding author: Tel.: +32 14 33 21 94; francisco.ja[email protected] stored indefinitely and there would be no losses with53 the environment as occurs with sensible heat storage.54 Therefore, if it is pretended to find some attractiveness in55 osmotic storage in comparison with traditional sensible56 heat, it must be in terms of capability for long time57 storage as well as compactness of the container.58 59 With this purpose in mind, there are two dimension-60 less numbers which can characterize transient heat con-61 duction in terms of long time storage as well as com-62 pactness, namely, the Fourier number Fo and the Biot63 number Bi. The Fourier number Fo conceptually, it is64 the ratio of diffusive or conductive transport rate to the65 quantity storage rate and is given by66 Fo =κt cpρL2(1) where κis the thermal conductivity; cpthe specific67 heat capacity, and ρthe density; tis the characteristic68 time; and Lis the characteristic length of the system.69 Because the Fourier number depends on time, it will ac-70 count the time for thermal storage. On the other hand,71 the Biot number Bi gives a simple index of the ratio of72 the heat transfer resistances inside of a body and at the73 surface of a body and is given by74 Bi =Lh κ(2) where his the heat transfer coefficient. It is easy to see75 that for our purpose, the Biot number gives account of76 the compactness of the system because it depend directly77 on the thickness of the isolator system. In fact, if we78 assume that the heat loss with the environment is only79 by conduction t by using an isolator with a thickness80 , say, δ, then the heat transfer coefficient is given by81
2 FIG. 1. Comparison between thermal sensible and thermal osmotic heat storage. Although the stored energy by sensible heat could be higher nevertheless the capability for storage is limited because the unavoidable losses with the environment. Contrariwise, osmotic energy can be stored indefinitely and only released when deliberately the two solutions are mixed. h=κi δwhere κiand δare the thermal conductivity and82 the thickness of the isolator. Thus Eq.(2 becomes83 Bi =κi κ L δ(3) and it is easy to see that in this way the Bi number84 is related with the compactness of the system and more85 precisely inversely to the compactness. So, if one desires86 a compact system, the thickness of the isolator should87 be a small as possible, i.e., L δ→0 and then Bi → ∞.88 Conversely, if the thickness of the isolator is very large,89 the compactness is reduced, Bi →0 and although it will90 store thermal energy for more time however this will be91 at the expense of compactness (and then increasing the92 cost of the system, e.g., larger containers, etc...).93 Therefore, long time storage as well as larger com-94 pactness, implies large Fourier numbers and large Biot95 numbers.96 97 Many formulations for analysis of transient conduc-98 tion based in those numbers are available in the litera-99 ture, however, for the purpose of the present work, the100 graphical analysis tool for the evaluation of heat transfer101 in thermal engineering, due to Heisler, [2], seems prefer-102 able. Figure 2, shows the Heisler curve for the volumetric103 heat transferred from the wall QL(or lost heat with the104 environment) as a function of a dimensionless number105 Bi2Fo for an infinite cylinder, where Qorepresents the106 initial internal energy content per volume of the body in107 reference to the environment temperature, which is given108 by109 Qo=ρcp∆T(4) where ∆T=Ti−Tois the difference of temperature110 with Tiis the initial temperature and Tothe environment111 temperature which is assumed to be constant.112 In order to compare the sensible heat storage with os-113 motic storage, the Heisler´curves can be used as follows:114 First, if we call the osmotic energy per unit of volume115 which can be stored induced by the precipitation of so-116 lute from a given ∆Tas Qπ, then the osmotic storage117 could be an attractive option in comparison with sensi-118 ble heat storage only after a certain time from which the119 sensible heat stored drops (because unavoidable thermal120 loses with he environment) below the energy which can121 be osmotically stored indefinitely. Therefore, for a given122 energy stored as sensible heat Qoosmotic storing starts123 to be more attractive when the following condition is ac-124 complished125 Qo[1−Ql Qo]≤Qπ(5) or126 Ql Qo ≥1−Qπ Qo (6) which considering Eq.(4) becomes127 Ql Qo ≥1−Qπ ρcp∆T(7) Thermal sensible heat storage Thermal osmotic heat storage Time energy mixing precipitation concentrated solution supernate heat loss limited storage time unlimited storage time
3 FIG. 2. Internal energy change for an infinite cylinder, [3]. FIG. 3. Biot versus Fourier number transient heat transfer for a plane wall, infinite cylinder and sphere derived from Heisler curves as depicted in Fig. 2 and for a ∆T= 80 K. •Discussion128 129 By using Eq.(7) and the Heisler´curves as plotted in130 Fig. 2, it is possible to obtain the region in which os-131 motic storage starts to be an option for heat storage if132 one knows the ∆Tfor sensible heat storage and the volu-133 metric energy Qπwhich can be osmotically stored using134 the same ∆T. As a manner of example, Fig. 3 gives the135 obtained curves for a plane wall, infinite cylinder and136 sphere using water with a ∆T= 80 K, the osmotic en-137 ergy which can be stored by precipitating the solute for a138 salt featuring a strong thermal dependence with the sol-139 ubility and at that temperatures as KNO3can be around140 ≈5 kWh/(m3) (cubic meter of solution), [1]. Referring141 to this figure, a cylindrical canister with a DeltaT = 80142 K osmotic storage could be an option in comparison with143 sensible heat storage when it is desired a system with a,144 say, Bi ≥10−1and a Fo ≥101. For a canister with,145 say, a radius of 5 cm and using air as insulator media,146 by using Eq.(3) with L= 10cm, i.e., the diameter of the147 canister this translates into a insulator gap of 5.24 cm,148 and a time storage (calculated from Eq.(1) around 9.68149 10- 5 10- 4 10- 3 10- 2 10- 1 100101102103104 0 . 1 0 . 2 0 . 3 0 . 4 0 . 5 0 . 6 0 . 7 0 . 8 0 . 9 1 . 0 B i 2F o 5 0 1 0 2 2 0 5 1 0 . 5 0 . 2 0 . 1 0 . 0 5 0 . 0 2 0 . 0 1 0.005 0.002 Ql/ Q o B i = h L / k = 0 . 0 0 1
4 days or therabouts.150 I. SUMMARY OF RESULTS AND151 CONCLUSIONS152 In this note, a first scoping study was performed in or-153 der to asses the attractiveness of osmotic thermal storage154 using aqueous solutions rather than sensible heat storage.155 Some interesting conclusions are derived as follows:156 (a) Sensible heat could store a larger amount of ther-157 mal energy than that stored by thermal osmosis.158 (b) However, for large Biot and Fourier numbers which159 translate into compact and long storage units, os-160 motic storage could be an attractive option.161 (c) Thermal osmotic storage for long and compact stor-162 age can find useful fields of applications when is163 desired compact and portable units able to provide164 with small inputs of energy and stored indefinitely165 for weeks or months.166 (d) Additional R&D is required in order to arrive at a167 reliable practical and commercial design168 Nomenclature169 a170 Bi = Biot number171 cp= heat capacity172 Fo = Fourier number173 h= heat transfer coefficient174 L= characteristic length175 Q= volumetric energy176 t= time177 T= temperature178 179 Greek symbols180 δ= thickness isolator181 κ= thermal conductivity182 ρ= density183 184 Acknowledgements185 186 This research was supported by the Spanish Ministry187 of Economy and Competitiveness under fellowship grant188 Ramon y Cajal: RYC-2013-13459.189 190 II. REFERENCES191 [1] Arias F.J. 2018. On osmotic heat engines driven by ther-192 mal precipitation-dissolution of saturated aqueous solu-193 tions. International Journal of Thermal Sciences. 133, p.p.194 151-161195 [2] Heisler M.P. 1947. Temperature Charts for Induction196 and Constant Temperature Heating. Transactions of the197 American Society of Mechanical Engineers, 69, 227-236.198 [3] Cengel, Yunus A. 2007. Heat and Mass Transfer: A Prac-199 tical Approach.3rd edition ed. McGraw Hill.200 [4] Lin S; Strauba A.P; Elimelech M. 2014. Thermodynamic201 limits of extractable energy by pressure retarded osmosis.202 8 Eenergy Environ. Sci. 2014. 7. 2706.203